Alaris TIVA syringe pump TIVA syringe pump
Transcription
Alaris TIVA syringe pump TIVA syringe pump
Alaris TIVA syringe pump Specifications ® Alaris TIVA syringe pump ® Rate Range 5ml syringe 10ml syringe 20ml syringe 30ml syringe 50ml syringe – – – – – 0.1 to 150 ml/h 0.1 to 300ml/h 0.1 to 600ml/h 0.1 to 900ml/h 0.1 to 1200ml/h – – – – – max bolus rate 150ml/h max bolus rate 300ml/h max bolus rate 600ml/h max bolus rate 900ml/h max bolus rate 1200ml/h Alaris Products ® Volume Infused 0.0 - 9990ml Bolus Rate 5ml syringe 10ml syringe 20ml syringe 30ml syringe 50ml syringe Dose Rate Units Available ml/h, ng/min, ng/kg/min μg/min, μg/kg/min, μg/h, μg/kg/h, μg/24h,μg/kg/24h mg/min, mg/kg/min, mg/h, mg/kg/h, mg/24h, mg/kg/24h,g/h, g/24h, U/min, U/kg/min, U/h, U/kg/h, U/24h, U/kg/24h,kU/24h, mmol/h Purge Rate 100 ml/h - 500 ml/h (limited to size of syringe) limit 0.5 - 5.0 ml Accuracy Volumetric +/- 2% (nominal) Syringe Type 5 ml, 10 ml, 20 ml, 30 ml or 50 ml disposable syringe of type specified on pump Battery Type Rechargable sealed NiMH, automatically charged when pump is connected to AC power Battery Life Battery life is typically 6 hours from full charged battery (5 ml/h @ 20°C under normal conditions) Consult operating instructions. Recharge Time 21/2 hours from discharge to 90% charge Pumping Pressure Limits Highest alarm level: 1000 mm Hg (L-10), Factory Preset: 300 mm Hg (nominal L-3) Occlusion levels L-0 to L-10. Alarms Audible alarm and display prompts with comprehensive protection for: • Pressure limit exceeded • Drive disengaged • Infusion complete • Purge/Bolus activated • Nurse CallBack • Near end infusion • Battery low • AC power failure • Syringe clamp AC power requirements 115-230 VAC, 50/60 Hz. 20 VA (nominal) CareFusion Australia 316 Pty Ltd Unit 3/167 Prospect Highway Seven Hills NSW 2147 Australia +61 2 9624 9000 tel +61 2 9624 9034 fax CareFusion NZ 313 Ltd 14B George Bourke Drive Mt. Wellington Auckland New Zealand +64 9 270 2420 tel 0508 422734 freephone +64 9 270 6285 fax CareFusion Solbråveien 10A 1383 Asker Norway +47 66 98 76 00 tel +47 66 98 76 01 fax CareFusion International Headquarters A-One Business Centre Zone d’activitiés Vers-la-Pièce no 10 1180 Rolle Switzerland +41 21 556 30 00 tel +41 21 556 30 99 fax CareFusion Unit 2 Oude Molen Business Park Oude Molen Road Ndabeni Cape Town 7405 South Africa +27 21 510 7562 tel +27 21 510 7567 fax CareFusion Hammarbacken 4B SE-191 24 Sollentuna Sweden +46 8 544 43 200 tel +46 8 544 43 225 fax © 2009 © 2010 CareFusion CareFusion Corporation Corporation or one or one of its ofsubsidiaries. its subsidiaries. All rights All rights reserved. reserved. Alaris Alaris is a registered and Smartsite trademark are registered of CareFusion trademarks Corporation of CareFusion or oneCorporation of its subsidiaries. or 0000CF00146 one of its Issue subsidiaries. 1 0000CF00379 Issue 1 Dimensions 310 mm (w) x 121 mm (h) x 200 mm (d) Weight (nominal) 2.7 kg Standards EN60601-1, EN60601-1-2, EN60601-2-24 CareFusion UK The Crescent Jays Close Basingstoke Hampshire RG22 4BS United Kingdom 0800 917 8776 freephone +44 (0)1256 330860 fax carefusion.com Alaris TIVA syringe pump Safety Disposables ® The perfect partner for IV anaesthesia Portability System Integration Capability Alaris syringe pumps are portable independently of the When docked to an Alaris ® Gateway Workstation, Alaris ® Medication Safety System. With all features available your complete infusion system has the capability to on the move and safety and intelligence built in. link to Patient Data Management Systems (PDMS) and ® Refer to Disposables Catalogue for the full range of illustrated products TIVA sets 500-002 • Y extension 2 way • 1 Back-check valve • 15cm • 1 Anti-siphon valve 500-003 • Y extension 3 way • 1 Back-check valve • 2 Anti-siphon valves • 15cm 500-012 • Y extension 2 way extension set • 220cm • 1 Anti-siphon valve • 1 Back-check valve 500-013 • Y extension 3 way extension set • 190cm • 1 Back-check valve • 2 Anti-siphon valve MFX2270 • Y extension 3 way • 3 Back-check valves • 2 Antisiphon valves • 2 Roberts clamps • 5.2ml* • 210cm MFX2271 • Extension line • 2 Back-check valves • Anti-siphon valve • Roberts clamp • 3.0ml* • 210cm MFX2290 • Y extension 3 way • 3 Back-check valves • 2 Antisiphon valve • Roberts clamps • 4.3ml* • 209cm MFX2291 • Y extension line • 2 Back-check valves 2.3ml* • 209cm MFX2292E • Y extension 3 way • SmartSite Valve • 3.9ml* • 210cm • 4 Back-check valves • 2 Anti-siphon valves Hospital Information Systems (HIS) through our open network architecture. ® Y connectors ® 20038E • Y connector 3 way • 3 SmartSite Valves • 3 Slide clamps • 0.3ml* • 11.5c 20061E • Y connector 2 way • 2 SmartSite Valves • 2 Slide clamps • 1.8ml* • 18cm • 2 Back-check valves 20062E • Y connector 3 way • 3 SmartSite Valves • Back-check valve • 3 Slide clamps • 1.5ml* • 16cm MFX2233E • Y connector 3 way ® • SmartSite Valve • 0.6ml* • 10cm • 2 Back-check valves ® ® Extension lines Pre-programmable drug protocols Pressure settings 100 pre-programmable drug protocols with on-screen 11 pressure settings - lets you select the appropriate verification before infusion starts. pump pressure for each infusion. G40615 • Extension line • Low sorbing • 1.5ml* • 150cm G40620 • Extension line • Low sorbing • 2ml* • 200cm G40720 • Extension line • Roberts clamp • Low sorbing • 1.5ml* • 200cm MFX2256 • Extension • Lipid resistant • 0.9ml* • 205cm MFX2260 • Extension line • Anti-siphon valve • 0.63ml* • 200cm MFX2280E • Stopcock extension • SmartSite Valve • Lipid resistant • 1ml* • 10cm MFX2284 • Stopcock extension • Lipid resistant • 7.2ml* • 100cm MFX2285 • Stopcock extension • Lipid resistant • 8.6ml* • 120cm ® Accessories 2000E7D ® • SmartSite Valve • 0.1ml* • 2.5cm (2000E in Australia/New Zealand) 2203E 2205E The Alaris ® TIVA syringe pump helps to administer IV anaesthesia drugs – so you can concentrate on improving patient care. • Simple to set up 2300E • Faster set-up of infusion parameters • Portable • Pre-programmable drug protocols Bolus dose facility Event log A range of bolus rates can be selected. “Hands-free” Easy access to a comprehensive event log, which allows infusion bolus doses can be adjusted, allowing the for a review of events recorded in real time. anaesthetist to focus on the needs of the patient. 2309E MFX1594E 30602N ® • SmartSite Valve vial access device (13mm vials) • 0.08ml* • 3.3cm ® • SmartSite Valve vial access device (20mm vials) • 0.08ml* • 3.7cm ® • Bag spike • Unvented • SmartSite Valve 0.46ml* • 8.33cm ® • Bag spike • Unvented • SmartSite Valve Backcheck valve • 0.86ml* • 12.5cm ® • Dispensing pin • SmartSite Valve • 0.2µm hydrophobic filter • 0.1ml* • 6.5cm ® • IVAC 50 ml Syringe * Priming volume Illustrations are only to be used as a guide and do not necessarily depict a true representation of the product.