TECHNICAL DATA
Transcription
TECHNICAL DATA
Blok TECHNICAL DATA New version length 29 29 95 80 121 45 height fixing centres 40 95 return flow allow minimum of 100mm for valves piping centres = length + dim X from relevant Valve Data Sheet 50 note: flow & return can be reversed if required see separate sheet for instructions Please note: this product was revised in October 2014 and fixing and pipe positions have changed. If you are unsure which version you have or require further clarification, please contact our technical team on 01276 605888 All dimensions shown are in millimetres Test pressure: Max working pressure: Max working temperature: Construction: 8 BAR 6 BAR 90º C extruded aluminium section with aluminium water circuit plastic chrome end trims ½ inch BSP opposite end tappings Connections: Heat output determined in accordance with EN 442 Manufactured for Bisque in Italy Model BLK 60-66 BLK 60-83 BLK 60-100 BLK 60-117 BLK 160-33 BLK 160-50 BLK-160-66 BLK 190-33 BLK 190-50 BLK 190-66 Output ÄT=30K Watts Output ÄT=50K Watts 325 406 487 569 376 564 752 433 649 866 634 793 952 1110 742 1113 1484 854 1281 1708 n 1.312 1.312 1.312 1.312 1.332 1.332 1.332 1.339 1.339 1.339 Water Content litres 1.10 1.38 1.65 1.93 1.30 1.95 2.60 1.54 2.31 3.08 Weight kg 9.8 12.3 14.7 17.2 12.3 18.5 24.6 14.5 21.8 29.0 Height ± 2mm Length ± 2mm Tapping Centres ± 2mm Fixing Centres ± 2mm 590 590 590 590 1590 1590 1590 1890 1890 1890 669 837 1005 1172 334 502 669 334 502 669 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 429 429 429 429 1429 1429 1429 1729 1729 1729 Issue 3.0 © Bisque, a division of Zehnder Group UK Ltd Blok FITTING INSTRUCTIONS New version Tools & Material Required Key Suitable valves PTFE tape Silicone thread sealant Tape measure Screwdriver - crosshead & flathead Electric drill Masonry drill bit - 8mm diameter Spirit level A B C D E F Component Qty Air Vent - 1/2” Blanking Plug Wall Plug Bracket Plastic Insert Screw - Csk Head, 5mm dia x 50mm 1 1 8 4 4 8 Assembly Instructions Sufficient PTFE tape must be applied to valve-tail thread prior to its installation. Silicone thread sealant should be applied to all threaded components manufactured with ‘O-rings’. Fit air vent (A) & blanking plug (B). Accurately mark out bracket holes on wall using spirit level. Drill eight 8mm diameter holes to a minimum depth of 60mm & insert wall plugs (C). Screw brackets (D) into wall plugs (C) with 5mm diameter x 50mm screws (F). Hang radiator on brackets, ensuring that the plastic inserts (E) in the brackets (D) engage with the rear face of the radiator. Plumb radiator to heating circuit with flow opposite air vent. Flow & diverter position indicated by a yellow plug. Diverter can be removed and swapped to other side if required. A This radiator should be installed onto a central heating system that has been cleaned/flushed and contains water treatment and inhibitor suitable for a mixed metal system in accordance with BS7593. F E B D C Please note: this product was revised in October 2014 and fixing and pipe positions have changed. If you are unsure which version you have or require further clarification, please contact our technical team on 01276 605888 Issue 3.0 © Bisque, a division of Zehnder Group UK Ltd Blok FLOW DIRECTION CONVERSION New version Please note: this product was revised in October 2014 and fixing and pipe positions have changed. If you are unsure which version you have or require further clarification, please contact our technical team on 01276 605888 air vent return plug C flow plug B plug A with diverter Standard Right Hand Flow with factory-fitted diverter air vent flow return plug C plug A with diverter plug B Left Hand Flow Conversion to convert from right hand to left hand flow, swap the positions of the factory-fitted plug A & plug B Issue 1.0 © Bisque, a division of Zehnder Group UK Ltd Blok TECHNICAL DATA Old version length 29 29 100 80 118 45 height fixing centres 58 100 return flow allow minimum of 100mm for valves piping centres = length + dim X from relevant Valve Data Sheet Please note: this product was revised in October 2014 and fixing and pipe positions have changed. If you are unsure which version you have or require further clarification, please contact our technical team on 01276 605888 All dimensions shown are in millimetres Test pressure: Max working pressure: Max working temperature: Construction: 50 8 BAR 6 BAR 90º C extruded aluminium section with steel water circuit plastic chrome end trims ½ inch BSP opposite end tappings Connections: Heat output determined in accordance with EN 442 Manufactured for Bisque in Italy Model BL 60-70 BL 60-87 BL 60-104 BL 60-121 BL 160-35 BL 160-52 BL-160-70 BL 190-35 BL 190-52 BL 190-70 Output ÄT=30K Watts Output ÄT=50K Watts n Water Content litres 367 458 550 641 398 598 797 451 676 901 712 890 1068 1246 790 1185 1580 898 1347 1796 1.30 1.30 1.30 1.30 1.34 1.34 1.34 1.35 1.35 1.35 1.76 2.20 2.64 3.08 1.50 2.25 3.00 1.68 2.52 3.36 Weight kg 11.2 14.0 16.8 19.6 13.8 20.7 27.6 16.2 24.3 32.4 Height ± 2mm Length ± 2mm Tapping Centres ± 2mm Fixing Centres ± 2mm 590 590 590 590 1590 1590 1590 1890 1890 1890 700 873 1046 1219 354 527 700 354 527 700 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 414 414 414 414 1414 1414 1414 1714 1714 1714 Issue 2.0 © Bisque, a division of Zehnder Group UK Ltd Blok FITTING INSTRUCTIONS Old version Tools & Material Required Key Suitable valves PTFE tape Silicone thread sealant Tape measure Screwdriver - crosshead & flathead Electric drill Masonry drill bit - 8mm diameter Spirit level Stepladder (for taller radiators) A B C D E F Component Qty Air Vent - 1/2” Blanking Plug Cover Cap Wall Plug Bracket Screw - Csk Head, 5mm dia x 50mm 1 1 2 8 4 8 Assembly Instructions Sufficient PTFE tape must be applied to valve-tail thread prior to its installation. Silicone thread sealant should be applied to all threaded components manufactured with ‘O-rings’. Fit air vent (A), blanking plug (B) & cover caps (C). Accurately mark out bracket holes on wall using spirit level. Drill eight 8mm diameter holes to a minimum depth of 60mm & insert wall plugs (D). Screw brackets (E) into wall plugs (D) with 5mm diameter x 50mm screws (F). Hang radiator on brackets, ensuring that the slots in the bottom brackets engage with the rear face of the radiator whilst the internal header sits in the radius of the top bracket. Plumb radiator to heating circuit with flow opposite air vent. Flow & diverter position indicated by a yellow plug. Diverter can be removed and swapped to other side if required. A Air vent is recessed so flathead screwdriver must be used to vent radiator. This radiator should be installed onto a central heating system that has been cleaned/flushed and contains water treatment and inhibitor suitable for a mixed metal system in accordance with BS7593. F E B C D Please note: this product was revised in October 2014 and fixing and pipe positions have changed. If you are unsure which version you have or require further clarification, please contact our technical team on 01276 605888 Issue 1.2 © Bisque, a division of Zehnder Group UK Ltd