Complete specification, „HAAS+SOHN Opus-II Legend to the drawing:

Transcription

Complete specification, „HAAS+SOHN Opus-II Legend to the drawing:
Art. No. 0618618020030
V14 H28
Complete specification, „HAAS+SOHN Opus-II 186.18“
Legend to the drawing:
No.
1
2
0618618006200
3
4
5
6
7
8
9
10
0618018006600
0618018015002
0089000020005
0020100130005
0050500040005
11
12
0618618005325
13
0618618005327
14
15
0618018005301
0618618006218
16
17
18
0050500050005
0618018008204
0088500050007
19
20
21
0618618005064
0618618005036
Name
Body of the stove black
Door of the fire-box
black
Fire clay
Room for storage of
wood
Ash-pan
Neck of the smoke flue
Adjustable legs
Secondary air
Grate
Upper return draft
board
Control of primary air
Attachment of the hand
pull of the door
Hand pull of the door of
the fire-box
Glass with sight hole
Screw of closing
the door
Insulating brick
Tongue of door shutting
Neck of the tube
Ø100mm
Air channel
Cable
Lower return draft
board
Caution! Before the installation, remove the safety catch on the left and on the right!
Installation of the lining of the fire-box (see drawing, page 3):
Note: The parts to be built-in are provided with labels with short descriptions.
1. Mounting of the 1st row: first the rear central brick (with the upper slot directed backwards), next the rear
bricks at the left and at the right (with the slots directed backwards), and the front bricks.
2. Insert the lower bricks 1, 2 and 3.
3. Insert the ash-pan (5) and the grate (9).
4. Mounting of the 2nd row: Rear bricks and lateral bricks.
5. Mount the insulating brick (16) and the return draft board (10 +21).
Installation of the insulating brick: Insert the short edge of the insulating brick (16) into the upper metal
sheet slot (see the drawing) and let it fit into the lower metal sheet slot.
Installation of return draft boards: Insert the return draft board (10) slantwise (with chamfered edges in
the rear) and lay it on lateral metal sheet angles; subsequently, lift the front edge and lay it on the holding
metal sheet.
Important: Insert the return draft board (10) forwards up to the stop!
Insert the lower return draft board (21) backwards up to the stop!
Important: After cleaning the appliance, and/or before bringing it in operation, it is necessary to check
whether the return draft board is in correct position (see the drawing).
Suitable fuels:
For the combustion in your fireplace stove, the following fuels are approved (see also the chapter 5.1.):
Dry, well-seasoned wood left in natural state, and wood briquettes according to DIN 51731.
Description of the conduction of combustion air:
The conduction of the combustion air in the fireplace insert Opus II 186.8 is divided into three sections:
The primary air is adjusted by means of the air controller (11): the primary air I flows through the grate
(position of the lever on the right), and the primary air II passes at the sides (positions of the lever on the
right) or centre. The secondary air for cleaning of the glass and additional combustion is optimised for the
fireplace stove, and adjusted fixedly in order to increase the comfort. The pre-heated secondary air
emerges at the upper end of the glass (8).
Position of the controller
on the right
centre
on the left
Primary air I
open
shut
shut
Primary air II
open
open
shut
Use:
for ignition and stoking of fuel
normal operation
for maintaining the fuel in glowing
state only
Connection of combustion air:
When operating the fireplace insert in airtight buildings, a reduction of contents of oxygen can occur at the
place of its location, and therefore, sufficient ventilation must be secured. For such a case, the fireplace
insert Opus-II 186.18 offers you the possibility of external suction of combustion air, thus operating the
fireplace insert independently from the air in the room. For this purpose, the combustion air must be
connected to the neck (18) by means of a flexible hose. The end of the air channel must be located
outdoors or in a well-ventilated room in the building. The operation of the fireplace insert in combination
with the operation of air-conditioning equipment is permitted. In case of installation of the fireplace insert in
combination with controlled ventilation of the living space, the end of the channel for input of air must not be
located in an area connected to the associated air-conditioning system.
The amount of fuel and adjusting of the combustion air controllers:
For ignition and heating in the appliance, see the chapters 5.4, 5.5 and 5.6 in the Operation Manual. For
the operation of air controllers, please use “cold hands” or the glove included in the delivery
Prior to each stoking, the air control system must be closed completely (lever in the position "on the left").
Fuel
maximum amount of fuel
Primary air, air controller
Secondary air
(without control)
Block wood
2 - 3 logs (about 2 – 2,5 kg)
Wood
briquettes
1 wood briquette (2 kg)
Leave open for a period of 10
minutes (slider on the right);
afterwards, transfer the slider
to its central position
open
Hint for burning of wood: After each first ignition in the appliance, leave the air controller in the
position "on the right", until the fuel starts burning lively (about 10 minutes). When stoking the fuel, please
close the air regulator, as indicated (the time data can vary slightly in dependence on the draft or
pressure).
Example of type plate:
HAAS + SOHN OFENTECHNIK GMBH
URSTEIN NORD 67 A-5412 PUCH
Fireplace insert – manner of construction: EN 13229-W / fire-box with interrupted combustion
Type designation:
Opus
Opus – II
Variant:
Serial No.:
1408186800085
Range of heat outputs:
3,9 -8,3 kW
Nominal heat output
8,0 kW
Approved fuel:
Wood, wood briquettes according to DIN 51731
Dust at 13% O2: 22 mg/Nm³
Energy efficiency: 80.3%
Temperature of combustion products: 320°C
NOx: 96 mg/Nm³
Minimum distances from inflammable
laterally:
construction parts:
in the rear:
in the front, in the extent of
the heat radiation:
Checking No. VKF: 11108
CO: 0,10%
HC: 42 mg/Nm³
see the Manual for situation
and operation
80 cm
Year of installation
Numeric symbol of the testing lab: 1625 / checking No. RRF-29 09 1931 2014
Read and observe the Operation Manual!
Multiple employment of a chimney is permitted
Checking No. EN 13229:
Flue lining Opus-II 186.18:
RRF Essen
RRF-29 09 1931
Building-in of the lining of the fire-box
Complete specification, „HAAS+SOHN Opus-II 186.18“
Lining of the fire-box:
Name:
BS1 (lower brick 1)
BS2 (lower brick 2)
BS2 (lower brick 3)
SR (lateral brick on the right)
SL (lateral brick on the left)
HSM (rear brick in the centre)
HSR (rear brick on the right)
HSL (rear brick on the left)
IS (Insulating brick)
Z (return draft board) 10
Z (return draft board) 21
Number:
1
1
2
1
1
2
2
2
1
1
1
Art. No.:
0050110490005
0050110500005
0050110480005
0050110120005
0050110110005
0050110060005
0050110070005
0050110140005
0050500050005
0050500040005
0618618005036