CRYOSAUNA SPECIFICATIONS
Transcription
CRYOSAUNA SPECIFICATIONS
CRYOSAUNA SPECIFICATIONS CRYOSAUNA CABIN DIMENSIONS Overall height with luminous roof 96” (8’ 4” clearance required) (XL unit: 100”) Overall height without luminous roof 88” (XL unit: 92”) Interior height of the cabin 72.25” base to top of cabin (XL unit: 76.25”) Width of the cabin with door 36.00” closed / 61” Open Overall length of the cabin 58.00” Height of a client 4’11” to 6’8” (XL Unit: 7’00”) VENTILATION Exterior Color Choices Vent Height 90.00” must vent to the outside Vent Hose Size two vents ~ approximately 4.875” each Ventilation built-in blower expels vapor to the outside Oxygen Monitor required to be installed near the unit LIQUID NITROGEN & ACCESS Industrial Grade LN2 3000L external tank with 75psi pressure valve Operating Pressure 44 to 85 PSI Dimension of hole for delivery of LN 2.50” hole for 2” pipe from tank(s) Recommend Hose / Piping Vacuum Jacketed (½” to ½” JIC fitting) ELECTRICAL DATA Rated power up to 1,5 kW power supply: 220V/50Hz Electrical Outlet 220V ~ Single Phase (3 Wire) NEMA L10-30 Receptacle & Plug: Cooper / AHL1030R & AHL1030P OPERATIONAL / TECHNICAL DATA Range of working temperatures -110°C/-160°C ( -166°F/-256°F ) Duration of a session 1 to 3 minutes (adjustable by operator) Advised initial session 1 minute 30 seconds Maximum session duration 3 minutes Cabin drying on end of cycle 90 to 120 minutes ©CRYO-220. ALL RIGHTS RESERVED | 214.814.0848 | RECOVER FASTER. PLAY HARDER℠