OMNIVORE 500 STEAM STERILIZATION WITH
Transcription
OMNIVORE 500 STEAM STERILIZATION WITH
STEAM STERILIZATION WITH OMNIVORE 500 OMNIVORE 500 is the latest modern non-incineration on-site solution for treating infectious hospital- and lab waste OMNIVORE 500 - INTEGRATED STERILIZER AND SHREDDER HEAVY DUTY ON-SITE SOLUTION TO CONVERT MEDICAL INFECTIOUS WASTE INTO STERILIZED BLACK BAG WASTE (MUNICIPAL WASTE) IN MINUTES! SAFE FOR THE ENVIRONMENT • • • • • • • • • • • • • • • • • • • • • Low cost per kg Low maintenance cost (no inflatable seals etc) Small footprint Immediate destruction of infectious waste Emission-and chemical -free sterilization(!) with steam alone Short cycle times (approx. <50 mins.) Load capacity approx. 50 kgs per cycle (approx. 500 l), in one load only Volume reduction up to 80% on bulky materials Destructing sharps and thin walled materials up to 1,5 mm Load/weight control Machine is fully sterilized after every cycle incl. the shredder Large touch-screen with real-time display All automatic (loading and unloading), unloading as option or as per request Separates liquids from solids and sterilizes both in a single process Special program for liquids (blood bags, urine etc.) High torque shredder (360 x 380 mm) Fits in every room with approx. 12 -14 sqm and a height of about 2,95 m Patent pending for special loading device incl. drop stop The shredder and its parts are sterilized every cycle Programmable cleaning cycles are built in the unit Microbiological inactivation by an Overkill Treatment (as recommended by the Robert-Koch-Institute, Berlin), with several pre-vacuums BIOHAZARD WASTE PROCESSING WITH OMNIVORE STEAM STERILIZATION WITH OMNIVORE 500 THE FOLLOWING ARE THE TECHNICAL FEATURES OF THE OMNIVORE 500 FOR PROCESS AND SAFETY: OMNIVORE is an advanced solution to perform a safe biomedical treatment which reduces risks, volume and weights (to a certain extent) and disposal cost. It carries out automated actions to sterilize infectious hospital waste incl. a pretreatment (multiple vacuum, conditioning, shredding) and a post treatment cycle (drying)! SECONDLY the machine provides a decontamination cycle designed to decontaminate the internal parts (incl. shredder) of the equipment, which during normal use, come into contact with the processed waste in order to render these parts safe to handle for maintenance and repairs. A validated process is used to render a product free from viable micro organisms. The sterilizing agent is saturated steam heat to inactivate hazardous microorganisms. The saturated steam or moisture is used in the form of steam or liquid water, both of which are equally effective in the inactivation of micro-organisms. No Chemicals are used. The hospital waste is exposed to internally/externally generated steam that is admitted into the sterilization vessel (autoclave approx. 210L). Moisture is also generated from water, that is already present in the waste itself, i.e. bottles of growth media from the laboratory by heating the water with steam. In the OMNIVORE 500 it is secured by the method, that both heat and moisture are present on the surfaces to be decontaminated.In the event that some surfaces are not readily exposed to the moist heat, i.e. in tubes or injection needles we have used additional means to make the surfaces accessible to the moist heat. The techniques used are shredding the waste and removing the air by vaccuum, to guarantee an effective sterilizing cycle. The time and temperature combinations specified for an acceptable disinfection and sterilizing process are valid for saturated moisture and steam as the sterilizing agent and the measured temperature is corresponding to the theoretical steam temperature. IN THE EVENT THOSE CRITERIAS ARE NOT MET, THE MACHINE WILL AUTOMATICALLY REPEAT THE PROCESS OR IN CASE OF A LEAKAGE WILL INFORM THE RESPONSIBLE PERSON AND STOP THE PROCESS. The information system will depict/display the exact cause via display/modem/alarm and print out. The sterilizing process includes the following stages: • Shredding of the waste and air removal (shredding with a max. torque of 3000Nm and knives of about 190 mm dia) • Shredding with 8 kWh approx. • Wetting and heating with 2 x 20 kWh (alternatively 3 x 20 kWh) for a fast cycle (< than 50 mins., even with a higher liquid content) • Sterilizing process with a plateau phase 10 or 20 mins at 135°C, 3,5 bar pressure • Drying with a very strong vacuum pump The sterilizing process has got clear start and end points and is conducted at a single temperature for a certain period (PLATEAU PHASE). Shredding is an effective way of bringing moist heat into contact with all of the surfaces of the waste materials. It also shreds sharps to as size which can be determined by the client by varying the size of the shredder teeth (option). Moreover shredding decreases the volume of bulky waste up to 80% and renders it absolutely unrecognizable to a approx. 1,2 cm size with a high torque of about 3000 Nm. Schredders are designed to reduce the size of the items in the waste to particles of a specified size range which is chosen to allow the penetration of the moist heat to the surfaces to be sterilized. The OMNIVORE 500 sterilization unit also includes the possibility of sterilizing the shredder during a routine cycle or, the sterilization of the shredder before maintenance or repair-/mal function. The lid, the filling funnel and the autoclave are hermetically closed when the shredder is in operation. Overpressure release vents are fitted with adequate air filters. The unit is designed to sterilize all possible items present in infectious hospital waste, including tubes, syringes, needles, suction bottles and growth media from the laboratory. It also sterilizes all other materials such as glass, fabrics, linen, woven-non-woven materials, paper, towels, certain quantities of diapers, blood bags, etc. Air removal allows for the rapid and even penetration of moist heat in porous and hollow materials. OMNIVORE 500 uses a fractionated vacuum which is absolutely necessary to remove air from hollow devices. All processes are described in DIN 58949-3 and validated by independent organizations recommended by the RKI-Institute, Berlin. All materials and substances emitted from the unit during or at the end of the process are sterilized. All air is filtered through special 0,2 micron filters before venting. It prevents the uncontrolled emission of fumes, aerosols and vapours hermetically sealed, operating at underpressure. Waste water is collected, thermally treated (135 °C) and sterilized. The water will only be released after meeting the set parameters. SAFETY 1. All sterilizing processes are reproducible. 2. Only one level of the program is available to the worker at the unit. 3. The Omnivore 500 provides a self-decontamination cycle which can be set automatically or manually in case of failure. 4. The efficacy of the self decontamination process is at least equal to a disinfection process of 15 mins. at 105 °C. 5. The machine automatically performs a leakage test before the new cycle starts. 6. Manual adjustments of the parameters of the unit are only possible by authorized persons using special keys/tools/administrator rights. 7. The unit has got min. 2 pressure transducers. 8. The unit is fitted with 2 independent temperature measurement systems. They do not deviate more than 1°C from the given sterilizing temperature. 9. The pressure can be easily monitored and recorded. The pressure measurement system does not deviate more than 4kPA from the pressure of the sterilizing temperature. 10. Recorded data parameters are presented as a graph. The results are sufficient to read all data with no need of additional optical enhancement systems or measuring systems. The 10" display displays all data in realtime. All recorded process data are indicated to the operator during the process. 11. The OMNIVORE 500 is fitted with a fault indication system. In the event of a fault, the cycle will be terminated and the cause indicated to the operator during the process. The meaning of the indications are proven to be clear to almost all operators. Means are provided to bring the process towards a safe situation to allow for removal of the waste. It is possible to terminate the process manually at any time, the termination is recorded by the process recorder. It is presumed that the waste is still contaminated and must be handled as such. The unit also provides an emergency program in the event, that the shredders stops or similar. The doors cannot be opened until released with the emergency program. 12. OMNIVORE 500, a double door sterilizing unit with an interlock system that prevents, that the unloading door can only be opened at the end of a successfully completed process. 13. All necessary certificates and homologations are available on request, such as • ISO 9001-2008 • CE includes DIN EN ISO TR 14121-1 • ISO DIN EN TS 17665(13) • DIN EN 285 and EN 556-1, • DIN EN ISO 11138-3 • TÜV certificates for the vessel 14. Warranty is 13 months from the shipping date(B/L date). 15. The OMNIVORE 500 has got a very low foot print to the environment. It does not emit any dangerous materials such as heavy metals, ozone, PCB, dioxin, furans or other dangerous chemicals or materials. It is discharging water only with a max. temperature of 65°C. With this machine you can continuously treat infectious waste up to 23 hours a day, resulting in a treatment volume of max. 1100 kgs per working day. STEAM STERILIZATION WITH OMNIVORE 500 PRODUCT SPECIFICATIONS Capacity: 500 L cycle (approx. 50 kgs per cycle if 1000L<=100kg) Autoclave chamber dimensions: Approx. 210 L Total cycle time: Approx. 50 mins (dep. on water content) Steam generator: 40 kWh alternatively 60 kWh Shredder: 8 kW (2 x 4 kW), high torque (3000 Nm) with 2 types of knives acc. to work materials used The following are the technical features: Shredding with 8 kW approx. Usable shredder size: 360 x 380mm, Shredder knives 190 mm dia., 3 or 6 teeth Entry/exit doors: Made from stainless steel with bayonet closures (no inflatable seals used), all automatic Automatic weighing system: With stop device overload (Option) Automatic loading system: With clamping device for wheelie pins from 80 L-240L, drip stop protection (Option) Automatic discharging system: Via compactor and sucking device (Option) SPECIAL PROGRAM FOR LIQUIDS Compressor: Build in compressor 12 bar, oil free Electronic: Siemens S 7 with a Siemens 10" touch screen monitor, with a predictive maintenance program, with internet connection to the factory to monitor the machine in case of technical issues Frame: Steel with black powder coating External steam source: Available as option, small unit 40/60 kWh with all connections, water softener, sludge cleaner, high pressure pump etc., original generators will be removed then Bodywork: Stainless steel 316 Piping: Stainless steel or teflon pipes/tubes Air/water condensation: Via 0,2 micron filter before venting STEAM STERILIZATION WITH OMNIVORE 500 Available on request with air conditioned control cabinet and humidity proof motors Tropical version: (option) Softened water 4 - 8 dH, min. flow 10 l/min, min. pressure 5-6 bar, automaticially Utilities: reduced to min. 4,5 bar 400 V - 50 Hz (40 or 60 kWh) as standard, other than that available as option Electricity: - built in printer, print time, sequences, pressure, temperature, date etc. Microbiological inactivation: SAL log -48 Plateau phase: 10/ alternatively 20 mins, 135 °C and 3,5 bar pressure Process: Sterilization process only by steam, no chemicals used and needed Sizes: W 1950 x D 1100 mm x H 2450 mm approx. Weight net: Approx. 1950 kgs (without options) Origin: Germany CAUTION: THE UNIT CANNOT ACCEPT CHEMICALS AS LIQUID OR SOLID MATERIAL, USED AND OVERDUE TABLETS ETC., RADIOACTIVE MATERIALS, CYTOSTATICS, MERCURY, LEAD, AMALGAM. BODY PARTS CAN BE USED WITH THE MACHINE, BUT KINDLY CHECK NATIONAL LAWS AND REGULATIONS. STERISHRED GmbH • Hürtimattstr. 30 • 6353 Weggis • Switzerland • www.sterishred.com