Generator Installation Problem Solvers Compatable with ANY Generator or Transfer Switch

Transcription

Generator Installation Problem Solvers Compatable with ANY Generator or Transfer Switch
Generator Installation Problem Solvers
Load Shedding Contactors and Relays From 50-200 Amp
Compatable with ANY Generator or Transfer Switch
50-100 Amp Contactor Panels with up to 8
different contactors and flush mount covers for
Faster, Easier & Less Expensive Install
Universal Stand-Alone 100 Amp Load Shedding
Relays. Automatically Disconnects load when
utility is lost and reconnects when restored.
Available in 120 & 24 Volt ac Coil
Works With ANY Generator
Universal contactor modules designed to work with any
generator or transfer switch load shedding controller. Custom
configured to each installation minimizing the size of the
generator needed while meeting the new National Electric
Codes.
Universal electronically controlled load dropping relays are
designed to work with ANY generator or transfer switch in
dropping loads up to 100 amps when utility power is lost. The
modules can be custom configured to each installation
minimizing the size of the generator needed while meeting the
new National Electric Codes.
Available in a variety of enclosures and can be configured with
up to 8 individually controlled contactors ranging in
combination from 50 to 100 amp loads
Relays are available in a variety of sizes and can be configured
with up to 4 electronically controlled relays ranging from 50 to
100 amp loads. Single 200 amp relay available.
Generator Transfer Switch Surge Protector
Sold Exclusively To The Trade ONLY
We have installed over
5000 Back-Up Generators
Green Light Indicates Protection is Active
Generator
Transfer Switch
Surge Protector
Phone 800-648-6802
www.pspproducts.com
UL Approved for Installation on Service Entrance Side
of Generator Transfer Switch before main breaker
Protects Transfer Switch, Generator and
Whole House From Damaging Surges.
Experience and know how have allowed us to put
together a line of money-making, labor saving
products that makes generator installations faster,
neater and more profitable.
Every product we sell comes with a full 30 day money
back guarantee. If for any reason a product purchased
from us fails to work in your application and we can’t
resolve the issue, send it back for a no questions asked
refund and we pay the shipping both ways.
Our team of experienced experts are available to
assist you with any generator installation issues you
may encounter.
PSP Products Inc. - 8535 Phoenix Drive, Manassas, VA 20110
www.pspproducts.com - 800-648-6802 Email [email protected]
Contactor and Relay Types
Definite Purpose Contactors
Designed primarily for inductive loads
Typically limited to 40 Amp circuits
Run noisy and hot with 120 volts AC or require step-down transformer
Limited life expectancy
Inexpensive and typically used in mass production devices
Industrial Grade Contactors
Designed for both inductive and resistive loads
Works with 120 or 24 Volts AC coil voltage with out overheating
Less prone to buzzing, humming and vibrating
Din Rail Mount for faster and easier installation
Available from 50 to 200 Amps
Open Frame Relay
Dual contacts provide normally- closed and normally-open contacts
Virtually silent operation, no heat, humming or buzzing when using normally
closed contacts.
Available in double pole 50 amp capacity
Magnetic Relays
Small foot print typically ¼ the size of a 100 & 200 amp contactors
Magnetic toggle is virtually silent operation, no heat, humming or buzzing
Available in 1, 2, 3 or 4 relay models
Available from 50 to 200 Amps
How Load Shedding Can Help You Sell More Generators
Problem: Customer has a 20KW Budget but wants to light up the entire house. The house has a 400 amp service
with two 200 amp panels and a 100 amp sub panel in the addition (opposite end of the house from generator) that
contains 60 Amp hot tub circuit.
Obvious Solution but over budget
Install a 60KW generator, 400 amp SER Switch and light the entire house up.
Utility
400 Amp
SR
Switch
60 KW
200 Amp
Main
200 Amp
Main
100 Amp
Sub Pan
A
B
Addition
60 Amp
Heat
60 Amp
B/U Heat
60 Amp
Hot Tub
Typical solution offered by most generator dealers
Install a 12KW generator, 16 circuit sub panel and limit the customer to 16 circuits.
Utility
Generator
16 Cir Sub
Panel
12 KW
200 Amp
Main
200 Amp
Main
100 Amp
Sub Pan
A
B
Addition
60 Amp
Heat
60 Amp
B/U Heat
60 Amp
Hot Tub
Solution Three
Install a 20KW generator, SR Transfer Switch. Load regulate the non essentials at power loss and light
up the entire house
Utility
400 Amp
SR
Switch
20 KW
200 Amp
Main
200 Amp
Main
A
B
Load Regulate
Load Regulate
80 Amp
Elec Heat
60 Amp
B/U Heat
Load
Regulate
100 Amp
Sub Pan
Addition
60 Amp
Hot Tub
Residential - Commercial
Modular Contactor Panel
Generator Load Shedding
50 - 65- 100 Amp Circuits
Allows 200 Amp Service Rated
Switch on Smaller Generators to
Meet National Electric Code.
1100DF121006-C
P345-13-004-C
Characteristics
•
UL Listed & IEC-60947
•
50, 65 and 100 Amp contactor modules
•
Any combination of 1- 8 contactor modules
•
Surface and Flush Mount Enclosures
•
Heavy duty industrial grade contactors
1100DF101004-C
Modular Load Shedding Contactor Assembly Features
• Universal Load Shedding contactors works with most generator transfer switches with load controllers
• Provides Load Shedding capabilities for up to 8 double pole circuits with 15-100 amp breakers/loads
• Reduces installation time and space requirements and assist in meeting the new NEC codes
• Din rail mounting allows for fast and easy customization for any configuration required
• Available in a variety of enclosure configurations including NEMA 01, NEMA 3R and NEMA 04
• Compact Flush Mount version fits inside of studs and flush cover extends 1” past edge of can on all 4
sides for finished walls.
50 - 65 - 100 Amp Contactor Specifications
Load Shedding Panels
LSC Series Contactor Specifications
50 Amp Relay
65 Amp Relay
100 Amp Relay
UL 508:
Ith
60Amps
100 Amps
135 Amps
Maximum Horse Power At 240 V AC Single Phase
7.5 Horse Power
10 Horse Power
15 Horse Power
Electrical
IEC-60947:
AC1 Load
AC3 Load 200-240 Volts
60 Amps
100 Amps
150 Amps
14KW / 50 Amps
18.5KW / 65 Amps
30KW / 100 Amps
Wire
CU Wire Only
CU Wire Only
CU Wire Only
Connection Terminal
Contactor Coil Voltage
Short Circuit
Operation Temperature (°C):
Contactor Mounting:
Warranty
Mechanical Lugs
Crimp Lugs
Crimp Lugs
120 Volts AC
120 Volts AC
5Ka RMS Sym 600 V Max
5Ka RMS Sym 600 V Max
-40°C to +85°C
120 Volts AC
-40°C to +85°C
Din-Rail
Din-Rail
12 Months
12 Months
10Ka RMS Sym 600 V Max
-40°C to +85°C
Din-Rail
12 Months
Enclosures and Contactor Wholesale Pricing
Select can size and add contactors as needed
Dimensions
8X8X04
NEMA
01
Mounting
Surface/Flush
Available Contactors
50 Amp Only
Maximum Units
2
Dealer Cost
$ 35.00
12X12X04
01
Surface/Flush
50 Amp Only
1-4
$ 40.00
20X14X04
01
Flush Mount
50/65/100 Amp
1-8
$ 97.00
12X08X06
01
Surface Mount
50/65/100 Amp
1-50 & 1-65/100
$ 43.00
12X12X06
01
Surface Mount
50/65/100 Amp
1-3
$ 45.00
12X08X06
3R
Surface Mount
65/100 Amp
1
$ 59.00
12X12X06
3R
Surface Mount
50/65/100 Amp
1-3
$ 59.00
12X12 & 8X8
01
Flush Mount Lid
Part Number
$15.00
Three Pole Contactors with Din-Rail Mounting Receiver
VKC1-50
50 Amp 3-Pole Contactor - 110 /24 Volts AC Coil
$
21.00
VKC1-65
VKC1-100
65 Amp 3-Pole Contactor - 110/24 Volts AC Coil
$
52.00
100 Amp 3-Pole Contactor - 110/24 Volts AC Coil
$
66.00
UL Listed Enclosures with Grounding Bars and Din-Rail
Residential - Commercial
100 & 200 Amp Models
Ultra Compact 100 & 200 Amp
Electronically Controlled
Universal Load Shedding Panel
Characteristics
•
UL 508 & IEC-60947
•
Electronically controlled with diagnostic LED
•
1- 4 Double Pole Relay Models Available
•
100 and 200 Amp Relay Configuration
•
Compact Magnetic Relays
•
Surface and Flush Mount Options
•
Operates with dry contact or AC Control Voltage
1100DF1208-1-10R
2-100 Amp Relays NEMA3R Enclosure
Universal Generator Load Shedding Module Features
• Universal Load Shedding circuitry works with virtually ANY generator or transfer switch
• Provides Load Shedding capabilities for up to 8 double pole circuits with 15-100 amp double pole breakers/loads
• Automatically removes load when utility power is lost and reconnects load when utility power is restored
• Utilizes Magnetic Relays eliminating the normal humming, chattering and heat associated with contactors
• Available in a variety of enclosure configurations including NEMA01, NEMA3R and NEMA04
• Compact Flush Mount version fits inside of studs and flush with sheet rock or finished wall
Ultra Compact 100 & 200 Amp
Electronically Controlled
Universal Load Shedding Panel
LSR Series Specifications
100 Amp Relays
Electrical
200 Amp Relays
Rated Load at 277 Volts
120 Amps
200 Amps
Maximum Continuous Operating AC Voltage
480 Volts
480 Volts
Insulation resistance
1,000 MΩ (at 500Vdc) 1,000 MΩ (at 500Vdc)
4,000 Vac for 1 min.
2,500 Vac for 1 min.
4,000 Vac for 1 min.
2,500 Vac for 1 min.
Maximum Switching Current
120 Amps
240 Amps
Maximum Switching Power
27,7000 VA
55,7000 VA
1000 M Ohms
1000 M Ohms
Dielectric strength:
Coil to contact
Across open contacts
Insulation Resistance
UL 508:
Ith
160 Amps
240 Amps
Maximum Horse Power At 240 V AC Single Phase
15 Horse Power
30 Horse Power
AC1 Load
150 Amps
300 Amps
AC3 Load 200-240 Volts
30 KW / 105 Amps
60 KW / 210 Amps
IEC-60947:
Mechanical
Connection Terminal
Mechanical Lugs
Mechanical Lugs
Operation Temperature (°C):
-40°C to +85°C
-40°C to +85°C
Enclosure Type
NEMA 01, 03R, 04
NEMA 01, 03R, 04
Weight:
TBD
Optional Flush Mount Cover Available:
Confidential Wholesale Pricing
Part Number
Dimensions
NEMA
Mounting
Number of Relays
Dealer Cost
1100DF1208-1-10R
10X10X04
01
Flush Mount
1 - 100 Amp Relay
$
185.00
1100DF1208-2-10R
12X12X04
01
Flush Mount
2 - 100 Amp Relays
$
235.00
1100DF1208-3-10R
12X12X04
01
Flush Mount
3 -100 Amp Relays
$
375.00
1100DF1208-4-10R
12X12X04
01
Flush Mount
4 -100 Amp Relays
$
425.00
P345-13-004-6-10R
20X14X04
01
Flush Mount
6 - 100 Amp Relays
$
645.00
1300-12086-1-10R
12X08X06
3R
Surface Mount
1 - 100 Amp Relay
$
215.00
1300-12086-2-10R
12X08X06
3R
Surface Mount
2 - 100 Amp Relays
$
265.00
1300-12086-3-10R
12X12X06
3R
Surface Mount
3 - 100 Amp Relays
$
395.00
1300-12086-4-10R
12X12X06
3R
Surface Mount
4 - 100 Amp Relays
$
455.00
HHC71F
2 Pole 50 AMP Normally Closed - Normally Open Relay
50 Amp Normally-Closed Relay
● Normally Open/Normally Closed contacts for universal application
● Box Lug termination
● Small Footprint, Standard open frame relay configuration
● UL and CUL Listed to 508 standard
● Available as an individual component or mounted in NEMA 01 or 3R enclosures with grounding bar
● Low profile allows for flush mounting in standard 2 X 4 stud wall
● Available in 120 Volts ac, 24 Volts ac and 12 Volts DC
HHC71F
2 Pole 50 AMP Normally Open - Normally Closed Relay
Specifications
Pole Configuration:
Maximum Switching Voltage:
Maximum Amperage:
Operating Voltage:
Maximum Voltage:
Contact Resistance:
Operate Voltage (25 C):
Release Voltage (25 C):
Operating Temperature:
Normal Coil Power:
Dialectric Strength :
Terminal Connections:
Coil Connections:
Listings:
DPDT Silver Alloy Contacts
250 Volts AC / 30 Volts DC
50 Amps/250 Volts AC
80% Rated Voltage
110% Rated Voltage
<100 Meg Ohm
80% Rated Voltage
30% Rated Voltage
-25 C to 55 C
10 VA
2500 VAC / 1 Min Leakage Current 1 ma
CU Rated Box Lug Terminals
Screw Terminal
UL / CUL
2.30
1.62
1.87
2.5
3.12
Specifications Subject to Change With Out Notice
KC-02 & GC-2
RELAY INVERTERs
120 Volt AC 2-Channel Relay Inverter
Use ANY standard 40-200 amp Normally Open
contactor with KOHLER®Load Shedding Controllers
KC-02 OVERVIEW
.
● Provides a Universal interface to adapt load shedding
controller outputs configured for normally Closed
relays to work with any Normally Open Contactor
● Works with any standard 120 Volt A.C. Contactor
● Two individual inputs Control two contactors
independently.
● Compact foot print only 1.5” X 3.5”
● Din-Rail Mountable
KC-02 Two Channel Relay Inverter
● Reduces wire clutter and simplifies installation
GC-02 OVERVIEW
Use ANY standard 50-amp normally closed relay
with Generac Load Shedding Controllers
.
● Provides a Universal interface to adapt load shedding
controller outputs configured for 120 volt contactor to work
with any Normally closed relay.
● Works with any standard 120 Volt normally closed relay.
● Two individual inputs Control two relays independently.
● Compact foot print only 1.5” X 3.5”
● Din-Rail Mountable
● Reduces wire clutter and simplifies installation
GC-02 Two Channel Relay
KC-02 & GC-02 Relay Inverters
120 Volt AC 16 Amp 2-Channel Relay Inverter
Typical Wiring Diagram KC-02
Specifications
KC-2 & GC-2
Standard N/O Contatactors
120 V AC In Put
120 V AC In Put
18 Volts AC
Stranded or Solid
12-22 gauge wire
Strip Length
5.5 - 7.0 mm
40°C to +85°C
NC
NC
Dry Contacts #2
86 Volts AC
Release Voltage
Terminal Wire Size
Dry Contacts #1
Dry Contacts #2
400Mw
Operate Voltage
6
To Contactor #2
120 Volts AC
Rated Coil Power
5
9 10 11 12
To Contactor #2
Dry Contacts #1
Input #1 Input #2
16 Amps @ 120 Volts AC
4
8
To Contacto #1
To Dry Contacts or KOHLER ®
Load Shedding Control Module
Maximum Contactor Coil Amps
Input Voltage
Wire
3
To Contactor #1
Model KC-2 Relay
Converter
7
120 Volts AC
Contactor Function Chart
Input #1 Open - Contactor #1 Energized
Input #1 Closed - Contactor #1 De- Energized
Input#2 Open - Contactor #2 Energized
Input##2 Closed - Contactor #2 De-Energized
2
Contactor #1
Operation Temperature (°C):
1
Contactor #2
Module Mounting:
Din-Rail
Module Size:
3.55” X 1.42” X 2.10”
Typical Wiring Diagram
Dimensions
KC-2 & GC-2
Typical Wiring Diagram GC-02
120 Volt Coil
Normally Closed
Works with the old and new version boards
See install sheet for various wiring diagrams
To Load Shedding
Control Module
120 V AC Line
120 V AC Neutral
Input 1
Input 2
3.55 in
6
5
4
9 10 11 12
To Relay#2
To Relay #2
Input #1
Not Used
120 Volts
AC
3
8
To Relay #1
Not Used
2
To Relay #1
Model KC-2 Relay
Converter
7
120 Volts AC
Contactor Function Chart
120 Vac input - Relay #1 De-energized
De-energized - Relay #1 Energized
120 Vac input - Relay #1 De-energized
De-energized - Relay #1 Energized
Input #2
1
Input #1
Input #1
Input #2
Input #2
1.429in
Load Shedding Controller
LSC-04 Programmable Load Shedding
4 Relay Control For Single & 3 Phase Application
Universal Load Shedding Control Module
4 Circuit Load Management Controller Overview
Utilizes dual CT inputs, not frequency loss for precision control of both small and large generators. Field adjustments
include individual current settings for each load, inrush current delay, startup and restore delay, generator full load amps
and CT matching adjust for universal installation.
Current Transformers
L1
+
L2
-
-
+
Closed - Utility Mode
Open - Generator Mode
Easy to use front panel
installer interface allows for
field programming.
Push to enter field to adjust mode
Controller Kit
Includes 4 channel
controller, 2 CT’s and 24
volt DC power supply
$279.00
Select Mode
Scroll to select field to adjust
Push to save adjustment
Open Frame
Relay
Standard
Contactors
HVAC
Control Wires
Contactor
Voltage
110/24Vac
Relay Voltage
110/24Vac
100-200 Amp
Latching
Relays
Universal dry contact outputs allows control of any contactor, relay or low voltage control circuit or
combination of multiple devices for most any load shedding application.
Programmable Features
Low Cost easy to use LSC-4 allows up to four loads to be controlled independently based on the available
power from the generator and the load on each contactor. No laptop or computer required, all adjustments can
be performed using the eight buttons on the front panel. Available in single and three phase configurations.
Works on any size generator.
Generator Full Load DR02- Adjust to generators
maximum amperage output in whole amps.
DelayShed DR01 - Delay period in seconds from the
generator start up until any loads will be reactivated.
Relay #1 Current DR03- Adjust to maximum amperage
output in whole amps for contactor # 1
Relay #2 Current DR04 - Adjust to maximum amperage
output in whole amps for contactor # 2
Relay #3 Current DR05- Adjust to maximum amperage
output in whole amps for contactor # 3
Relay #4 Current DR06 - Adjust to maximum amperage
output in whole amps for contactor # 4
Actual Generator Current as measured by the
controller (Real Time)
Inrush Time DR08- Adjust controller delay in seconds
when restoring/activating loads to allow for inrush
preventing premature load shedding
CT Full Current DR09: Calibration adjustment set in
amps for CT maximum current rating
Real Time State of contactors
Residential
Light Commercial
Applications
GEN-160-SER Service Entrance Rated
Generator Transfer Switch Surge Protector
Green Light Indicates Protection is Active
GEN-160-SER Overview
The GEN-160-SER is designed to be the first line of defense
against damaging electrical surges and spikes originating from
utility power lines. The GEN-160-SER is UL 1449 3rd edition
listed and designed for installation at the Utility Entrance side of
the generator transfer switch providing robust protection for both
the transfer switch and the whole home against damaging electrical
surges and spikes.
Generator
Transfer Switch
Surge Protector
Phone 800-648-6802
www.pspproducts.com
UL Approved for Installation on Service Entrance Side
of Generator Transfer Switch before main breaker
GEN-160-SER Transfer Switch Protector Features
● UL 1449 3rd edition type 1 listed.
● Flush mount plate option available for finished walls.
● Common mode suppression with 160,000 Surge Amp Capacity
● Thermal fused metal oxide varistor (MOV) suppression technology
● Light-emitting diode (LED) visual indicator for transfer switch protection status
● Type 4 Enclosure suitable for transfer switches installed inside or outdoors.
● Provides whole house surge protection
● Lifetime Warranty with $25,000 down line protection coverage.
Sold Exclusively To Generator Installation Companies and Electrical Contractors Only.
Your customer will Never find this product available in supply houses, retail locations or on the Internet.
GEN-160-SER Service Entrance Rated
Generator Transfer Switch Surge Protector
Electrical
GEN-160-SER
Model
Type 1 Service Entrance Rated
Surge Protection Device (SPD) Type to UL
120/240V Single Phase
3W+G
Operating AC Voltage
Maximum Continuous Operating AC Voltage (MCOV):
Line-Neutral
140 V
Line-Ground
140 V
Neutral-Ground
140 V
Line-Line
280 V
20 kA
Nominal Discharge Current [In]
Maximum Surge Current Capacity [Imax]: Line-Neutral
80 kA
Line-Ground
80 kA
Neutral-Ground
80 kA
Line-Line
100 kA
10kA No Breaker
Fault Current Rating
200ka With Breaker
Voltage Protection Rating (VPR):
Line-Neutral
600 V
Line-Ground
1000V
Neutral-Ground
600 V
Line-Line
1000V
Suppression Technology
MOV
Listing
UL 1449 3rd Edition Type 1
Mechanical
Connection Terminal (Suppression) Hardwired
#12 AWG pigtail leads
Operation Temperature (°C)
-40° C to +80° C
Enclosure Type (Outdoor)
Type 4 PVC Plastic
Enclosure Dimension (L ×W × H)
4.0
Weight
2.5 lbs [1.81 kg]
Pr o d u c t Di a g r a m
× 4.0 × 2.45 [294.14 × 130.43 × 62.31mm]
[8.0”
[294.14]
11.58
[62.31]
2.45
[101.60]
4.00
[32.46]
1.28
[50.80]
2.00
[8.0”
[50.80]
2.00
[130.43]
4.00
[mm]
inches
5.00
Optional Flush Mount Cover
GSP-01
CONTROL WIRE SURGE
PROTECTION
25,000 Per Mode Control Wire Surge Protector
®
Protects Generac Generator Control Circuits from
damaging electrical surges and transients
GSP-01 OVERVIEW
Overview
Provides 25,000 surge amp of protection
per mode for L1 and L2, 120 Volt source
line to control board, 12 Volt DC power
supply line, generator transfer control line
and potential neutral to ground transients.
Diagnostic LED indicated all modes of
surge protection are functioning.
GSP-01 5 Mode Control Wire Surge Protector
•Protects Utility Sense L1 & L2
•Protects Utility 120 Volt Charge Circuit
•Protects Neutral Line
•Protects 12 Volt DC Power Supply
•Protects Transfer Signal Control Line
•Diagnostic LED Monitors Protection
GSP-01
CONTROL WIRE SURGE
PROTECTION
25,000 Per Mode Control Wire Surge Protector
Specifications
T1-120 Volts AC Charge
MCOV: ………………………...
Imax:………………………………
N1-120 Volt Utility Sense
MCOV:…………………………….
Imax:………………………………
N1-120 Volt Utility Sense
MCOV:…………………………….
Imax:………………………………
Neutral to Ground
MCOV:…………………………….
Imax:……………….……………..
194 12 Volts DC
MCOV:……………………………
Imax:………………………………
23 Transfer
MCOV:……………………………
Imax:………………………………
In. All Modes
8/20 Ka 1449 3rd Edition:………
Wire Terminals…………………..
150 Volts
25,000 Amps
150 Volts
25,000 Amps
150 Volts
25,000 Amps
150 Volts
25,000 Amps
18 Volts DC
25,000 Amps
18 Volts DC
25,000 Amps
20,000 Amps
Screw terminals 18~12 AWG
Terminal Configuration
0 Ground
Neutral
Not Required
T1 Output
LED indicates
surge protection is
Connect Ground wire Using
Shortest Lead Length Possible
Neutral
Not Required
Din-Rail Mounting Procedure
T1 Input
Din-Rail
N1 Output
Control wires out to
generator control board
Model GSP-1
Surge Protector
N2 Output
N1 Input
N2 Input
194 12VDC
194 12VDC In
23 Transfer Out
23 Transfer In
Control wires in from
transfer switch
Enclosure Types
4” Deep Surface / Flush Mount NEMA 01 Enclosures
8X8X4 NEMA 01
12X12X04 NEMA 01
20X14X04 NEMA 01
6” Deep Surface Mount NEMA 01 Enclosures
12X08X06 NEMA 01
12X10X06* NEMA 01
12X12X06 NEMA 01
6” Deep Surface Mount NEMA 3R Enclosures
12X6X6* NEMA 3R
12X8X6* NEMA 3R
*Denotes Special Order
12X12X06 NEMA 3R
Contactor Rating Definitions
A.C. Applications
Category AC-1
This category applies to all types of a.c. load with a power factor equal to or greater than 0.95
Application examples: heating, distribution.
Category AC-2
This category applies to starting, plugging and inching of slip ring motors.
On closing, the contactor makes the starting current, which is about 2.5 times the rated current
of the motor.
On opening, it must break the starting current, at a voltage less than or equal to the mains supply
voltage.
Category AC-3
This category applies to squirrel cage motors with breaking during normal running of the motor.
On closing, the contactor makes the starting current, which is about 5 to 7 times the rated current
of the motor.
On opening, it breaks the rated current drawn by the motor; at this point, the voltage at the
contactor terminals is about 20% of the mains supply voltage. Breaking is light.
Application examples: all standard squirrel cage motors: lifts, escalators, conveyor belts, bucket
elevators, compressors, pumps, mixers, air conditioning units, etc... .
Rated conventional thermal current (Ith)
The current which a closed contactor can sustain for a minimum of 8 hours without its
temperature rise exceeding the limits given in the standards.
Rated operational voltage
(Ue)use of the contactor or starter, and on which the corresponding tests and the utilization category
are based. For 3-phase circuits it is expressed as the voltage between phases.
Apart from exceptional cases such as rotor short-circuiting, the rated operational voltage Ue is
less than or equal to the rated insulation voltage Ui.
Rated control circuit voltage (Uc)
The rated value of the control circuit voltage, on which the operating characteristics are based.
For a.c. applications, the values are given for a near sinusoidal wave form (less than 5% total
harmonic distortion).
Rated insulation voltage (Ui)
This is the voltage value used to define the insulation characteristics of a device and referred to
in dielectric tests determining leakage paths and creepage distances. As the specifications are
not identical for all standards, the rated value given for each of them is not necessarily the same.
Rated impulse withstand voltage (Uimp)
The peak value of a voltage surge which the device is able to withstand without breaking down.
Rated operational power (expressed in kW)
The rated power of the standard motor which can be switched by the contactor, at the stated
operational voltage.
Rated breaking capacity (2)
This is the current value which the contactor can break in accordance with the breaking
conditions specified in the IEC standard.
Rated making capacity (2)
This is the current value which the contactor can make in accordance with the making conditions
specified in the IEC standard.
On-load factor (m)
This is the ratio between the time the current flows (t) and the duration of the cycle (T)
m=
Cycle duration: duration of current flow + time at zero current
Pole impedance
The impedance of one pole is the sum of the impedance of all the circuit components between
the input terminal and the output terminal.
The impedance comprises a resistive component (R) and an inductive component (X = L ).
The total impedance therefore depends on the frequency and is normally given for 50 Hz.
This average value is given for the pole at its rated operational current.
Electrical durability
This is the average number of on-load operating cycles which the main pole contacts can
perform without maintenance. The electrical durability depends on the utilization category, the
rated operational current and the rated operational voltage.
Mechanical durability
This is the average number of no-load operating cycles (i.e. with zero current flow through the
main poles) which the contactor can perform without mechanical failure.
Current Special
3 - 50 Amp Contactor Panel Assembly
Includes
1 - 12” X 12” x 04” NEMA 01 Steel Powder Coated
Enclosure with standard cover and hardware
3 - 50 Amp Contactors with 120 or 24 Volt ac Coils
with snap-in Din-Rail mounting receiver
Pre-Installed Din-Rail and grounding bars for fast
and hassle free installation.
Optional Flush-Mount Cover available
Only $89.00
PSP Products Inc.
8535 Phoenix Drive
Manassas, VA 20110