ARROW PRESSURE INJECTABLE PICC

Transcription

ARROW PRESSURE INJECTABLE PICC
ARROW PRESSURE INJECTABLE PICC
Expect more from your PICC
EXPECT MORE
FROM YOUR PICC
DISTINCT LABELING
pressure injection capabilities
are marked on the extension line
hubs with each lumen’s
maximum flow rate
FLEXIBLE LOW PROFILE
JUNCTION HUB
designed for patient comfort
and easy of maintenance
The arrow Pressure Injectable PICC was developed for
ease-of-use, smooth insertion and patient comfort. Arrow
PICC is the choice for those who simply demand more from
their PICC.
The arrow Pressure Injectable PICC is a polyurethane open
ended catheter, indicated for short or long-term peripheral
access to the central venous system for intravenous therapy,
blood sampling, central venous pressure monitoring, infusions and power injection of contrast media.
PRESSURE INJECTION CAPABILITY
The maximum pressure of power injector equipment used
with the Pressure Injectable PICC may not exceed 300 psi
while the maximum flow rate of infusion is 4 ml/sec (single
and double lumens PICC) and 6ml/sec (triple lumens PICC).
The arrow Polyurethane ensures high resistance while
maintaining softness and gentleness once into the vessel.
TAPERFREE™ CATHETER
DESIGN
same French size between
distal tip and the hub, reduces
the risk of thrombosis2,3,4
CHOOSE THE RIGHT LENGTH,
DO NOT TRIM THE TIP
The arrow Pressure Injectable PICC is available in three different lengths (40, 50, 55 cm) thus eliminating the need to trim
the line and avoiding to alter the integrity of the catheter itself. This means saving all the benefits related to the Blue Flex Tip
and the Staggered Exit Ports.
BLUE FLEX TIP ® & STAGGERED
EXIT PORTS
The contoured design is softer than the
rest of the catheter, which allows for
smooth maneuvering through narrow,
tortuous vessels with less trauma.
With this unique tip design, multilumen PICC’s have staggered ports.
These ports are intended to reduce
the risk of medications mixing and
creating a precipitate that could
potentially occlude the catheter1 .
The Blue Flex Tip® is also designed
to track better over wire.
With the Blue Flex Tip, it is also
the only PICC that can be inserted
without a sheath in over-the-wire interventional insertions. It provides instant
visual confirmation upon the removal.
BLUE FLEX TIP®
Unique to Arrow. Soft contoured tip design to enhance
maneuverabilitywhile minimizing vessel trauma
Blunt, ragged tip
on conventional
trimmable catheter poses
risk of intimal trauma
STAGGERED EXIT PORTS
reduce the risk of mixing
incompatible medications
that can create precipitate1
The soft, contoured tip
is designed to be easier
to maneuver and
minimize trauma
DOUBLE NUMBERING
simplifies documentation
of catheter length
PRODUCT & ORDERING INFORMATION
PRESSURE INJECTABLE PICC
Lumen
1
1
1
2
2
2
3
3
3
outer ø
(Fr)
Inner Ø*
(Gauge)
LengtH
(Cm)
Max Flow Rate*
(mL/sec)
Flow Rate*
(mL/hr)
Ref.
Kit Configuration
EU-24041-HPMSB
Max Barrier Nursing
qty
EU-04041-HP
Basic Nursing
EU-04041-IR
Interventional Radiology
10
EU-25041-HPMSB
Max Barrier Nursing
5
EU-05041-HP
Basic Nursing
EU-05041-IR
Interventional Radiology
10
EU-25541-HPMSB
Max Barrier Nursing
5
EU-05541-HP
Basic Nursing
EU-05541-IR
Interventional Radiology
EU-24052-HPMSB
Max Barrier Nursing
5
4
18
4
40
18
4
4
50
18
1020
4
55
10
720
4
10
660
10
10
5
5
18/18
4/4
EU-04052-HP
Basic Nursing
EU-04052-IR
Interventional Radiology
10
EU-25052-HPMSB
Max Barrier Nursing
5
EU-05052-HP
Basic Nursing
EU-05052-IR
Interventional Radiology
EU-25552-HPMSB
Max Barrier Nursing
EU-05552-HP
Basic Nursing
EU-05552-IR
Interventional Radiology
EU-24063-HPMSB
Max Barrier Nursing
EU-04063-HP
Basic Nursing
EU-25063-HPMSB
Max Barrier Nursing
EU-05063-HP
Basic Nursing
EU-25563-HPMSB
Max Barrier Nursing
EU-05563-HP
Basic Nursing
5
40
18/18
50
630/720
4/4
10
540/600
10
10
5
5
18/18
4/4
55
480/540
10
10
6
17/19/19
40
6/NoCT/NoCT
1650/550/550
6
17/19/19
50
6/NoCT/NoCT
1320/480/450
6
17/19/19
55
6/NoCT/NoCT
1070/390/360
5
10
5
10
5
10
*Distal/Proximal/Medial
Gauze Pad 5cmx5cm
Gauze Pad 10 cm x 10 cm
Ultrasound Sterile Probe Cover
•
•
Measuring tape
•
Tape
•
Tourniquet
•
Transparent Dressing
•
Sutureless Fixation Device
•
Hemo-Hopper Fluid Receptacle
•
Towel
•
Absorbent Towel
•
Cap
•
Mask with Eyeshield
•
Mask
•
Surgical gown
•
Fenestrated drape
•
Full Body drape
3 ml Syringe
•
Needle Free Connectors
10 ml Syringe
•
Catheter trimmer, Safety
22Ga Hypodermic Needle, Safety
•
Sharps Away Locking Disposal Cup
25 Ga Hypodermic Needle, Safety
•
Filter Needle
Scalpel, Safety
0.018 in x 130 Cm Stainless Steel Guidewire
0.018 in x 45 Cm Nitinol Guidewire
Interventional
Radiology Kit
Echogenic Introducer Needle 21Gax7Cm
Basic Nursing Kit
GlideThru™ Microintroducer
Maximal Barrier
Nursing Kit
Arrow Pressure Injectable PICC
Kit configuration
KIT COMPONENTS
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SAME SIZE
FROM TIP TO HUB
Our attention to detail and focus on safety extends over the
entire length of the catheter. arrow PICCs are taper-free
as we strive to make procedures complication-free. The
arrow TaperFree™ catheter design assures the clinician
stated size is consistent between the distal and proximal
ends. Long tapered catheter bodies can be up to two
French sizes larger than what’s actually labeled5. This
presents you with a catheter to vessel ratio that increases
the risk of thrombosis 2,3,4.
5Fr RISK OF THROMBOSISRISES
AS FRENCH SIZE INCREASES 2
10%
9.8%
RISK OF THROMBOSIS
8%
6.6%
6%
4%
2%
1%
0%
4 Fr.
5 Fr.
SIZE OF CATHETER
1
2
3
4
5
6 Fr.
5Fr REVERSE FREE DESIGN
According to a study published in the Journal of Vascular
and Interventional Radiology, the risk of thrombosis rises
as French size increases3 (see chart). To minimize this
risk, the authors recommend using the smallest acceptable catheter required for the therapy. With a tapered catheter body there can be a considerable difference between
the French size at the tip and the French size at the proximal end. This type of design puts the widest portion of the
catheter into the narrowest portion of the vein.
For the sake of their patients, clinicians need to know that
the French size of their PICC does not vary. With Arrow
PICCs you can depend on it. In fact, a study evaluating outcomes associated with a 6 French reverse tapered triple
lumen PICC, was stopped prematurely due to unacceptably
high venous thrombosis rate4.
Collins JL, Lutz RJ. In Vitro Study of Simultaneous Infusion of Incompatible Drugs in Multilumen Catheter. Heart & Lungs. 1991; 20(3):271-7
Nifong, T., McDevitt, T. The Effect on Catheter to Vein Ratio on Blood Flow Rates in a Sumulated Model of Peripherally Inserted Central Venous
Grove JR, Pevec WC. “Venous Thrombosis Related to Peripherally Inserted Central Catheters.” Journal of Vascular and Interventional Radiology. 2000; 11: 837-840.
Trerotola, S., Stravropoulos, S., Mondeschein, J., Patel, A., Fishman, N., Fuchs, B., Kolansky, D., Kasner, S., Pryor, J., Chittams,
J. Triple-Lumen Peripherally Inserted Central Catheter in Patients in the Critical Care Unit: Prospective Evaluation. Radiology. 2010; 256 (1.2).)
Data on file
Teleflex is a leading global provider of specialty medical devices used for
diagnostic and therapeutic procedures in critical care, urology and surgery.
Our mission is to provide solutions that enable healthcare providers to
improve outcomes and enhance patient and provider safety.
We specialise in devices for general and regional anaesthesia, cardiac care,
respiratory care, urology, vascular access and surgery and we serve healthcare
providers in more than 150 countries. Teleflex also provides specialty products
for medical device manufacturers.
Our well known brands include arrow ®, deKnatel®, gibecK®, hudson rci®,
KMedic ®, lMa™, Pilling®, Pleur-evac ®, rÜsch®, sheridan®, taut ®, tfx oeM®,
vasonova™, vidacare ® and wecK®, all of which are trademarks or registered
trademarks of Teleflex Incorporated.
Teleflex global operations: Australia, Austria, Belgium, Canada, China,
Czech Republic, France, Germany, Greece, India, Ireland, Italy, Japan, Malaysia,
Mexico, Netherlands, New Zealand, Portugal, Singapore, Slovak Republic,
South Africa, Spain, Switzerland, United Kingdom, Uruguay and USA.
YOUR INTERNATIONAL CONTACTS:
TELEFLEX HEADQUARTERS INTERNATIONAL, IRELAND
Teleflex Medical Europe Ltd., IDA Business and Technology Park,
Dublin Road, Athlone, Co Westmeath
Phone +353 (0)9 06 46 08 00 · Fax +353 (0)14 37 07 73
orders.intl@teleflex.com
AUSTRALIA/NEW ZEALAND +61 (0)3 9081 0600
AUSTRIA +43 (0)1 402 47 72
BELGIUM +32 (0)2 333 24 60
CHINA (SHANGHAI) +86 (0)21 6163 0965
CHINA (BEIJING) +86 (0)10 6418 5699
CZECH REPUBLIC +420 (0)495 759 111
FRANCE +33 (0)5 62 18 79 40
GERMANY +49 (0)7151 406 0
GREECE +30 210 67 77 717
INDIA +91 (0)44-2836 5040
ITALY +39 0362 58 911
JAPAN +81 (0)3 3379 1511
NETHERLANDS +31 (0)88 00 215 00
PORTUGAL +351 22 541 90 85
SINGAPORE +65 6439 3000
SLOVAK REPUBLIC +421 (0)3377 254 28
SOUTH AFRICA +27 (0)11 807 4887
SPAIN +34 918 300 451
SWITZERLAND +41 (0)31 818 40 90
UNITED KINGDOM +44 (0)1494 53 27 61
For detailed information see www.teleflex.com
The products in this catalogue may not be available in all countries. Please contact your local representative.
All data current at time of printing (10/2014). Subject to technical changes without further notice.
94 11 10 - 00 00 01 · REV A · MC / WM · 10 14 01.5