96300849.02_EXWUID 35.45.indd
Transcription
96300849.02_EXWUID 35.45.indd
Energy 1200 Installation Primary Switched Power Supply 1200W EXWUID 35.45 programmable V/I/P Digital Programming Ordering Information Type Output Input Voltage Housing Dimensions see drawing Article No.*1 EXWUID 35.45 V = 0V 35V* I = 0A 45A* P = 0W - 1200W* 100-240Vac 406x150x108mm 752-001-00 *1 Housing inside chrome plated, housing outside anodized * Delivery condition Content Ordering Informations 1 Accessories 2 Mechanical Dimensions 3 Technical Data 4-6 Pin Configuration 7, 8 Output Characteristics KNIEL does not accept any liability for typographical or other errors. All specifications are subject to change without prior notice. page 9 photo for example 1 11/2014 doc.: 96300849.02 - also effective: description no 95930034 Energy 1200 Installation Primary Switched Power Supply 1200W EXWUID 35.45 programmable V/I/P Digital Programming Accessories Article-No. Mains connection X1 with cable housing without cable housing Connector - PC 4/3-ST-7.62 screwable connections 3 pole, AWG 12-24 400-116-00 400-056-00 Output connection X2 Connector - IPC 16/3-STF-10.16 screwable connections 3 pole, AWG 6-18 400-123-00 Sense lead connection X3 Connector - IC 2.5/2-STF-5.08 screwable connections 2 pole, AWG 24-14 400-119-00 I/O-Signal connection X4 Connector D-SUB, 15 pole Male High Density solderable connections until AWG 22 400-106-00 Loadshare connection X5 Connector - MC 1.5/3-STF-3.81 screwable connections 3 pole, AWG 16-26 400-120-00 CAN connection X6 Connector RJ45 (2x) insulation-displacement terminal contacts, AWG 22-26 400-104-00 RS232 connection X7 Connector RJ45 (2x) insulation-displacement terminal contacts, AWG 22-26 400-104-00 Type Kit 02 Kit consisting of: Article No. Article No. mounted on device 402-116-00 402-116-10 2 x mounting strip 6 x special screw M4 x 6 Installation device for example with mounting strips 406.0 3 108 150 20 20 6.0 174 15.0 4.2 203.0 391.0 Doc.: 96300849.02 - also effective: description no 95930034 11/2014 2 – + X3 + SENSE – X2 X4 SIGNAL X5 LOADSHARE X5 X4 OUTPUT OUT 4 X6 CAN 0 --> 1 --> ON 1 SETTINGS 0 Interfaceconfiguration via DIP-switch 1 1 Interfaceconfiguration via EEPROM 0 Analoginterface (optional) inactive without function 2 1 Analoginterface (optional) active 3, 4 SETTINGS N MAINS X1 PE EXT. HMI X11 INTERFACE 3 2 1 0 0 0 RS232 1 0 0 CAN 0 1 0 USB 1 1 0 LAN * (optional) 0 0 1 reserved 1 0 1 reserved 0 1 1 reserved 1 1 1 reserved L1 RESET BOOT * fixed 57.6 kBit/s BAUDRATE (kBit/s) 5 4 ASCII CAN 0 0 9.6 50 1 0 19.2 125 0 1 57.6 250 1 1 115.2 1000 1 X7 8 1 IN 0 --> 1 --> 8 Double pole / neutral fusing The power supply is under voltage as soon as the mains input connector is applied with voltage. The units connectors may only be plugged or unplugged in mains-switch-off - condition. Otherwise the contacts of the plugs may be damaged. 1 SETTINGS RS232 X10 ON 4 X8 ANALOG Node 8 7 6 ASCII CAN 0 0 0 128 10 1 0 0 1 11 0 1 0 2 40 1 1 0 3 41 0 0 1 4 80 1 0 1 5 81 0 1 1 6 120 1 1 1 7 121 installation STANDBY ON RUN (CAN) optional ON CV CC OUT FAIL energy 1200 Caution USB 201.0 ! 406.0 X3 X2 150.0 X9 rear side LAN 43.0 X1 108.0 View B front side X7 X6 X8 X11 1 2 configuration optional (in bottom sheet) 4.0 View A 1 = LEDs 2 = Standby/on switch X7 = RS232 connection (2x) X8 = USB connection X11 = Ext. HMI X4 = I/O-Signal connection X5 = Loadshare connection X6 = CAN connection (2x) X1 = Mains connection X2 = Output connection X3 = Sense lead connection doc.: 96300849.02 - also effective: description no 95930034 11/2014 3 : Please note: plugs and connected electrical lines protrude the general outline of the unit. Please refer to the data sheets of the respective accessories. ! programmable V/I/P EXWUID 35.45 6 x M4, 5mm thread depth for mounting 30.0 2.0 ERROR (CAN) 142.0 Energy 1200 Installation Primary Switched Power Supply 1200W Digital Programming Dimensions in mm 55.0 <-- B A --> 372.0 Energy 1200 Installation Primary Switched Power Supply 1200W EXWUID 35.45 programmable V/I/P Digital Programming Technical Data (Guaranteed values after a warm-up period of approx. 15 min. at nominal load, measured at the unit´s output) Type 35.45 Output Voltage* [Vdc] 0 - 35 Output Current* [A] 0 - 45 Output Power* [kW] Type of Regulation 0 - 1.2*1 primary switched Efficiency [%] ≥ 87 Load Change 0... 100% [mV] ≤ 30 Input Voltage Change (90–264V) [mV] ≤ 15 Load Change 0... 100% RNOM [mA] ≤ 100 Input Voltage Change (90–264V) [mA] ≤ 15 Load Change inside of Vmax and Imax [W] ≤ 10 Input Voltage Change (90–264V) [W] ≤5 Static Voltage Regulation Current Regulation Power Regulation Dynamic Voltage Regulation Control Deviation ∆ IO = 65...100% INOM [mV] Load Current Change dIO/dt [A/μs] ≤ 300 0.1 Control Time for ∆ IO = 65...100% INOM [ms] ≤ 0.5 Discharge Circuit Continuance Power (tol.±2%) Peak Power (tol.±2%) Quality [W] [W] / [ms] 80 400 / 300 Voltage Regulation Residual Ripple (100Hz) [mVPP] ≤ 20 Operating Frequency Ripple (200kHz) [mVPP] ≤ 25 Superimposed Switching Spikes [mVPP] ≤ 100 [mAPP] ≤ 75 Residual Ripple (100Hz) [mVPP] ≤ 20 Operating Frequency Ripple (200kHz) [mAPP] ≤ 50 Operating Frequency Ripple (200kHz) [mVPP] ≤ 50 Current Regulation Residual Ripple (100Hz) Start-up Delay after Mains on Power-up Time after Standby/on; Enable Overvoltage Protection (OVP) Software Hardware (tol.+2V) Residual Voltage after Tripping [s] [ms] [V] [V] [V] Sense Lead Operation (load line compensation) [V] * 7 < 100 38.5 40 0 max. 1.5 per load line Set values below 0.5% of the maximum value are near the basic accuracy of the power supply. *1 For input voltages between 90 and 150Vac the maximum output power is limited to 1000W. Doc.: 96300849.02 - also effective: description no 95930034 11/2014 4 Energy 1200 Installation Primary Switched Power Supply 1200W EXWUID 35.45 programmable V/I/P Digital Programming Technical Data (Guaranteed values after a warm-up period of approx. 15 min. at nominal load, measured at the unit´s output) Type 35.45 Input Voltage [Vac] [Hz] Frequence (up to 440Hz on request) 100 - 240 ± 10% (90 - 264) 50 - 60 ± 10% (45 - 66) in the Event of Mains Failure at Nominal Load: Buffer time tBuff [ms] ≥ 25 tB [ms] ≥ 15 Prewarning time tP [ms] ≥ 10 Bridging time Power Factor λ according to EN 61000 3-2 ≥ 0.95 Input Voltage Ieff max at Vin = 115/230Vac –20% [A] 13 / 7.5 Starting Inrush Current IP for 230Vac [A] ≤ 30 [A] 2 x 16 gR Unit Fuse (internal) Air Inlet Temperature [°C] – 20... 0… + 50, without derating; internal temperature-regulated fan Storage Temperature Range [°C] – 40... + 85 Weight approx. [kg] 5 For definitions, informations about electrical safety, EMC and mechanical stressability see description. 5 11/2014 doc.: 96300849.02 - also effective: description no 95930034 Energy 1200 Installation Primary Switched Power Supply 1200W EXWUID 35.45 programmable V/I/P Digital Programming Technical Data Programming Type 35.45 Temperature Drift [ppm/K] ≤ 150 (for all set values and actual values) V- Control Set Value Input (digital set value --> output value) Step Size [mV] 10.55 max. Digital Error [%] 0.2 max. Analogue Error [%] 0.1 max. Total Error (∆ϑ 35K) [%] 0.83 absolute Error (∆ϑ 35K) [V] 0.29 Actual Value Output (output value --> digital actual value) Step Size [mV] 10.55 max. Digital Error [%] 0.15 max. Analogue Error [%] 0.1 max. Total Error (∆ϑ 35K) [%] 0.78 absolute Error (∆ϑ 35K) [V] 0.27 Programming Times 0 --> Vmax Vmax --> 10% Vmax nominal load open circuit nominal load open circuit [ms] [ms] [ms] [ms] ≤ 20 ≤ 30 ≤ 30 ≤ 45 I- Control Set Value Input (digital set value --> output value) Step Size [mA] 13.88 max. Digital Error [%] 0.2 max. Analogue Error [%] 0.3 max. Total Error (∆ϑ 35K) [%] 1.03 absolute Error (∆ϑ 35K) [A] 0.46 Actual Value Output (output value --> digital actual value) Step Size [mA] 13.88 max. Digital Error [%] 0.15 max. Analogue Error [%] 0.3 max. Total Error (∆ϑ 35K) [%] 0.98 absolute Error (∆ϑ 35K) [A] 0.44 P- Control Set Value Input (digital set value --> output value) Step Size [mW] 585.53 max. Digital Error [%] 0.4 max. Analogue Error [%] 0.4 max. Total Error (∆ϑ 35K) [%] 1.33 absolute Error (∆ϑ 35K) [W] 16.22 Actual Value Output (output value --> digital actual value) Step Size [mW] 585.53 max. Digital Error [%] 0.3 max. Analogue Error [%] 0.4 max. Total Error (∆ϑ 35K) [%] 1.23 absolute Error (∆ϑ 35K) [W] 15 For set values < 2% of the nominal value, the unit operates in open-circuit output in two-limits mode, whereby the output ripple increases. For set value ”0” the unit remains in open circuit and in the event of low load a residual voltage of lower 300mV remains at the output. Doc.: 96300849.02 - also effective: description no 95930034 11/2014 6 Energy 1200 Installation Primary Switched Power Supply 1200W EXWUID 35.45 programmable V/I/P Digital Programming Pin Configuration Mains Connection X1 (Power Combicon 3 pole / series PC 4) L1 N 1 Sense Lead Connection X3 (Combicon 2 pole) Earth PE 2 –S 3 1 grid = 7.62mm I/O-Signal Connection X4 (D-Sub-HD connector 15 pole) +S 10 15 5 11 1 2 6 grid = 5.08mm Signal name Pin Signal name Pin Signal name Pin L1 1 – Sense 1 1 Enable - 1 - A * N 2 + Sense 1 2 Enable - 1 - K * 2 OUT-A: FS (C) 3 OUT-B: PFS (C) 4 OUT-C: VF 5 Earth PE 3 Output Connection X2 (Power Combicon 3 pole / series IPC 16) PE – Loadshare Connection X5 + 2 Pin Signal name 1 LS 1 – Out 2 LS-GND 2 + Out 3 Earth 7 PE 11/2014 6 GND 7 8 IN-C: (A) IN-C: (K) 9 10 Enable - 2 - A * 3 Signal name 5V GND (unit socket, Mini-Combicon) 1 2 3 1 (C) (Shield) Pin 1 11 Enable - 2 - K * 12 OUT-A: FS (E) 13 OUT-B: PFS (E) 14 OUT-C: VF 15 (E) * With two Enable inputs (1 and 2) both Performance Level (PL) d according to EN ISO 13849-1 and Safety Integrity Level (SIL) 2 according to EN/ IEC 62061 are fulfilled. 3 doc.: 96300849.02 - also effective: description no 95930034 Energy 1200 Installation Primary Switched Power Supply 1200W EXWUID 35.45 programmable V/I/P Digital Programming Pin Configuration CAN Connection X6 (2 x RJ45 connector) Ext. HMI X11 (Connector, D-Sub-HD 15-pol.) RS232 Connection X7 (2 x RJ45 connector) 10 8 1 8 1 1 8 1 8 15 5 11 1 6 Signal name CAN H CAN L GND-CAN nc* nc* nc* GND-CAN nc* Pin 1 2 3 4 5 6 7 8 Pin assignment according to CiA DRP303-1 Signal name nc* nc* nc* GND-RS232 RxD TxD nc* nc* Pin 1 2 3 4 5 6 7 8 Internal connection * Pins marked "nc" may not be connected external. Explanations see description. Pin assignment according to EIA-561 Advice: All metallic connector housings are related to protective earth. USB Connection X8 (connector, type B) 2 1 3 4 Signal name Pin VCC D– D+ 1 2 3 GND 4 Doc.: 96300849.02 - also effective: description no 95930034 11/2014 8 Energy 1200 Installation Primary Switched Power Supply 1200W EXWUID 35.45 programmable V/I/P Digital Programming Output Characteristics V/I/P - Setting ranges V/V 35 1.2kW P-regulation 26.7 input voltage range 110Vac 22 0 I/A 0 9 11/2014 28.5 34.3 45 doc.: 96300849.02 - also effective: description no 95930034