Energy 1200 Installation Primary Switched Power Supply 1200W
EXWUID 35.45
programmable V/I/P
Digital Programming
Ordering Information
Type
Output
Input
Voltage
Housing Dimensions
see drawing
Article No.*1
EXWUID 35.45
V = 0V 35V*
I = 0A 45A*
P = 0W - 1200W*
100-240Vac
406x150x108mm
752-001-00
*1 Housing inside chrome plated, housing outside anodized
* Delivery condition
Content
Ordering Informations
1
Accessories
2
Mechanical Dimensions
3
Technical Data
4-6
Pin Configuration
7, 8
Output Characteristics
KNIEL does not accept any liability for typographical or other errors.
All specifications are subject to change without prior notice.
page
9
photo for example
1
11/2014
doc.: 96300849.02 - also effective: description no 95930034
Energy 1200 Installation Primary Switched Power Supply 1200W
EXWUID 35.45
programmable V/I/P
Digital Programming
Accessories
Article-No.
Mains connection
X1
with cable housing
without cable housing
Connector - PC 4/3-ST-7.62
screwable connections 3 pole, AWG 12-24
400-116-00
400-056-00
Output connection
X2
Connector - IPC 16/3-STF-10.16
screwable connections 3 pole, AWG 6-18
400-123-00
Sense lead connection
X3
Connector - IC 2.5/2-STF-5.08
screwable connections 2 pole, AWG 24-14
400-119-00
I/O-Signal connection
X4
Connector D-SUB, 15 pole Male High Density
solderable connections until AWG 22
400-106-00
Loadshare connection
X5
Connector - MC 1.5/3-STF-3.81
screwable connections 3 pole, AWG 16-26
400-120-00
CAN connection
X6
Connector RJ45 (2x)
insulation-displacement terminal contacts, AWG 22-26
400-104-00
RS232 connection
X7
Connector RJ45 (2x)
insulation-displacement terminal contacts, AWG 22-26
400-104-00
Type
Kit 02
Kit consisting of:
Article No.
Article No. mounted on device
402-116-00
402-116-10
2 x mounting strip
6 x special screw M4 x 6
Installation device for example with mounting strips
406.0
3
108
150
20
20
6.0
174
15.0
4.2
203.0
391.0
Doc.: 96300849.02 - also effective: description no 95930034
11/2014
2
–
+
X3
+
SENSE
–
X2
X4
SIGNAL
X5
LOADSHARE
X5
X4
OUTPUT
OUT
4
X6
CAN
0 -->
1 -->
ON
1
SETTINGS
0 Interfaceconfiguration via DIP-switch
1 1 Interfaceconfiguration via EEPROM
0 Analoginterface (optional) inactive
without function
2 1 Analoginterface (optional) active
3, 4
SETTINGS
N
MAINS
X1
PE
EXT. HMI
X11
INTERFACE
3 2 1
0 0 0 RS232
1 0 0 CAN
0 1 0 USB
1 1 0 LAN * (optional)
0 0 1 reserved
1 0 1 reserved
0 1 1 reserved
1 1 1 reserved
L1
RESET BOOT
* fixed 57.6 kBit/s
BAUDRATE (kBit/s)
5 4 ASCII CAN
0 0
9.6
50
1 0 19.2
125
0 1 57.6
250
1 1 115.2 1000
1
X7
8
1
IN
0 -->
1 -->
8
Double pole / neutral fusing
The power supply is under voltage as soon as the
mains input connector is applied with voltage.
The units connectors may only be plugged or
unplugged in mains-switch-off - condition. Otherwise the contacts of the plugs may be damaged.
1
SETTINGS
RS232
X10
ON
4
X8
ANALOG
Node
8 7 6 ASCII CAN
0 0 0 128
10
1 0 0
1
11
0 1 0
2
40
1 1 0
3
41
0 0 1
4
80
1 0 1
5
81
0 1 1
6
120
1 1 1
7
121
installation
STANDBY ON
RUN (CAN)
optional
ON
CV
CC
OUT
FAIL
energy 1200
Caution
USB
201.0
!
406.0
X3
X2
150.0
X9
rear side
LAN
43.0
X1
108.0
View B
front side
X7 X6
X8
X11
1
2
configuration
optional
(in bottom sheet)
4.0
View A
1 = LEDs
2 = Standby/on switch
X7 = RS232 connection (2x)
X8 = USB connection
X11 = Ext. HMI
X4 = I/O-Signal connection
X5 = Loadshare connection
X6 = CAN connection (2x)
X1 = Mains connection
X2 = Output connection
X3 = Sense lead connection
doc.: 96300849.02 - also effective: description no 95930034
11/2014
3
: Please note: plugs and connected electrical lines protrude the general outline of the unit.
Please refer to the data sheets of the respective accessories.
!
programmable V/I/P
EXWUID 35.45
6 x M4, 5mm thread depth
for mounting
30.0
2.0
ERROR (CAN)
142.0
Energy 1200 Installation Primary Switched Power Supply 1200W
Digital Programming
Dimensions in mm
55.0
<-- B
A -->
372.0
Energy 1200 Installation Primary Switched Power Supply 1200W
EXWUID 35.45
programmable V/I/P
Digital Programming
Technical Data
(Guaranteed values after a warm-up period of approx. 15 min. at nominal load, measured at the unit´s output)
Type
35.45
Output Voltage*
[Vdc]
0 - 35
Output Current*
[A]
0 - 45
Output Power*
[kW]
Type of Regulation
0 - 1.2*1
primary switched
Efficiency
[%]
≥ 87
Load Change 0... 100%
[mV]
≤ 30
Input Voltage Change (90–264V)
[mV]
≤ 15
Load Change 0... 100% RNOM
[mA]
≤ 100
Input Voltage Change (90–264V)
[mA]
≤ 15
Load Change inside of Vmax and Imax
[W]
≤ 10
Input Voltage Change (90–264V)
[W]
≤5
Static
Voltage Regulation
Current Regulation
Power Regulation
Dynamic
Voltage Regulation
Control Deviation
∆ IO = 65...100% INOM
[mV]
Load Current Change dIO/dt
[A/μs]
≤ 300
0.1
Control Time for
∆ IO = 65...100% INOM
[ms]
≤ 0.5
Discharge Circuit
Continuance Power (tol.±2%)
Peak Power
(tol.±2%)
Quality
[W]
[W] / [ms]
80
400 / 300
Voltage Regulation
Residual Ripple (100Hz)
[mVPP]
≤ 20
Operating Frequency Ripple (200kHz)
[mVPP]
≤ 25
Superimposed Switching Spikes
[mVPP]
≤ 100
[mAPP]
≤ 75
Residual Ripple (100Hz)
[mVPP]
≤ 20
Operating Frequency Ripple (200kHz)
[mAPP]
≤ 50
Operating Frequency Ripple (200kHz)
[mVPP]
≤ 50
Current Regulation
Residual Ripple (100Hz)
Start-up Delay after Mains on
Power-up Time after Standby/on; Enable
Overvoltage Protection (OVP)
Software
Hardware
(tol.+2V)
Residual Voltage after Tripping
[s]
[ms]
[V]
[V]
[V]
Sense Lead Operation (load line compensation) [V]
*
7
< 100
38.5
40
0
max. 1.5 per load line
Set values below 0.5% of the maximum value are near the basic accuracy of the power supply.
*1 For input voltages between 90 and 150Vac the maximum output power is limited to 1000W.
Doc.: 96300849.02 - also effective: description no 95930034
11/2014
4
Energy 1200 Installation Primary Switched Power Supply 1200W
EXWUID 35.45
programmable V/I/P
Digital Programming
Technical Data
(Guaranteed values after a warm-up period of approx. 15 min. at nominal load, measured at the unit´s output)
Type
35.45
Input Voltage
[Vac]
[Hz]
Frequence (up to 440Hz on request)
100 - 240 ± 10%
(90 - 264)
50 - 60 ± 10%
(45 - 66)
in the Event of Mains Failure
at Nominal Load: Buffer time
tBuff
[ms]
≥ 25
tB
[ms]
≥ 15
Prewarning time tP
[ms]
≥ 10
Bridging time
Power Factor λ
according to EN 61000 3-2
≥ 0.95
Input Voltage
Ieff max at Vin = 115/230Vac –20%
[A]
13 / 7.5
Starting Inrush Current IP for 230Vac
[A]
≤ 30
[A]
2 x 16 gR
Unit Fuse (internal)
Air Inlet Temperature
[°C]
– 20... 0… + 50, without derating; internal temperature-regulated fan
Storage Temperature Range
[°C]
– 40... + 85
Weight approx.
[kg]
5
For definitions, informations about electrical safety, EMC and mechanical stressability see description.
5
11/2014
doc.: 96300849.02 - also effective: description no 95930034
Energy 1200 Installation Primary Switched Power Supply 1200W
EXWUID 35.45
programmable V/I/P
Digital Programming
Technical Data Programming
Type
35.45
Temperature Drift
[ppm/K]
≤ 150
(for all set values and actual values)
V- Control
Set Value Input
(digital set value --> output value)
Step Size
[mV]
10.55
max. Digital Error
[%]
0.2
max. Analogue Error
[%]
0.1
max. Total Error (∆ϑ 35K)
[%]
0.83
absolute Error (∆ϑ 35K)
[V]
0.29
Actual Value Output (output value --> digital actual value)
Step Size
[mV]
10.55
max. Digital Error
[%]
0.15
max. Analogue Error
[%]
0.1
max. Total Error (∆ϑ 35K)
[%]
0.78
absolute Error (∆ϑ 35K)
[V]
0.27
Programming Times
0 --> Vmax
Vmax --> 10% Vmax
nominal load
open circuit
nominal load
open circuit
[ms]
[ms]
[ms]
[ms]
≤ 20
≤ 30
≤ 30
≤ 45
I- Control
Set Value Input
(digital set value --> output value)
Step Size
[mA]
13.88
max. Digital Error
[%]
0.2
max. Analogue Error
[%]
0.3
max. Total Error (∆ϑ 35K)
[%]
1.03
absolute Error (∆ϑ 35K)
[A]
0.46
Actual Value Output (output value --> digital actual value)
Step Size
[mA]
13.88
max. Digital Error
[%]
0.15
max. Analogue Error
[%]
0.3
max. Total Error (∆ϑ 35K)
[%]
0.98
absolute Error (∆ϑ 35K)
[A]
0.44
P- Control
Set Value Input
(digital set value --> output value)
Step Size
[mW]
585.53
max. Digital Error
[%]
0.4
max. Analogue Error
[%]
0.4
max. Total Error (∆ϑ 35K)
[%]
1.33
absolute Error (∆ϑ 35K)
[W]
16.22
Actual Value Output (output value --> digital actual value)
Step Size
[mW]
585.53
max. Digital Error
[%]
0.3
max. Analogue Error
[%]
0.4
max. Total Error (∆ϑ 35K)
[%]
1.23
absolute Error (∆ϑ 35K)
[W]
15
For set values < 2% of the nominal value, the unit operates in open-circuit output in two-limits mode, whereby the output ripple increases.
For set value ”0” the unit remains in open circuit and in the event of low load a residual voltage of lower 300mV remains at the output.
Doc.: 96300849.02 - also effective: description no 95930034
11/2014
6
Energy 1200 Installation Primary Switched Power Supply 1200W
EXWUID 35.45
programmable V/I/P
Digital Programming
Pin Configuration
Mains Connection X1
(Power Combicon 3 pole / series PC 4)
L1
N
1
Sense Lead Connection X3
(Combicon 2 pole)
Earth PE
2
–S
3
1
grid = 7.62mm
I/O-Signal Connection X4
(D-Sub-HD connector 15 pole)
+S
10
15
5
11
1
2
6
grid = 5.08mm
Signal name
Pin
Signal name
Pin
Signal name
Pin
L1
1
– Sense 1
1
Enable - 1 - A *
N
2
+ Sense 1
2
Enable - 1 - K *
2
OUT-A: FS
(C)
3
OUT-B: PFS (C)
4
OUT-C: VF
5
Earth
PE
3
Output Connection X2
(Power Combicon 3 pole / series IPC 16)
PE
–
Loadshare Connection X5
+
2
Pin
Signal name
1
LS
1
– Out
2
LS-GND
2
+ Out
3
Earth
7
PE
11/2014
6
GND
7
8
IN-C:
(A)
IN-C:
(K)
9
10
Enable - 2 - A *
3
Signal name
5V
GND
(unit socket, Mini-Combicon)
1
2
3
1
(C)
(Shield)
Pin
1
11
Enable - 2 - K *
12
OUT-A: FS
(E)
13
OUT-B: PFS (E)
14
OUT-C: VF
15
(E)
* With two Enable inputs (1 and 2) both
Performance Level (PL) d according
to EN ISO 13849-1 and Safety Integrity Level (SIL) 2 according to EN/
IEC 62061 are fulfilled.
3
doc.: 96300849.02 - also effective: description no 95930034
Energy 1200 Installation Primary Switched Power Supply 1200W
EXWUID 35.45
programmable V/I/P
Digital Programming
Pin Configuration
CAN Connection X6
(2 x RJ45 connector)
Ext. HMI X11
(Connector, D-Sub-HD 15-pol.)
RS232 Connection X7
(2 x RJ45 connector)
10
8
1
8
1
1
8
1
8
15
5
11
1
6
Signal name
CAN H
CAN L
GND-CAN
nc*
nc*
nc*
GND-CAN
nc*
Pin
1
2
3
4
5
6
7
8
Pin assignment according to
CiA DRP303-1
Signal name
nc*
nc*
nc*
GND-RS232
RxD
TxD
nc*
nc*
Pin
1
2
3
4
5
6
7
8
Internal connection
* Pins marked "nc" may not be connected external.
Explanations see description.
Pin assignment according to EIA-561
Advice:
All metallic connector housings are
related to protective earth.
USB Connection X8
(connector, type B)
2
1
3
4
Signal name
Pin
VCC
D–
D+
1
2
3
GND
4
Doc.: 96300849.02 - also effective: description no 95930034
11/2014
8
Energy 1200 Installation Primary Switched Power Supply 1200W
EXWUID 35.45
programmable V/I/P
Digital Programming
Output Characteristics
V/I/P - Setting ranges
V/V
35
1.2kW P-regulation
26.7
input voltage range
110Vac
22
0
I/A
0
9
11/2014
28.5 34.3
45
doc.: 96300849.02 - also effective: description no 95930034