In-Carpet Specification Guide
Transcription
In-Carpet Specification Guide
I N - C A R P E T W I R E WAY ARCHITECTURAL SOLUTIONS FOR OPEN SPACE POWER AND CONNECTIVITY Connectrac In-Carpet Wireways offer discrete and elegant power and technology connectivity in open interior spaces of all kinds. They combine an extruded aluminum central wireway flanked by ultra-low sloping floor transition ramps, creating a subtle, powerful and beautiful cable pathway solution for virtually any need. Extremely durable and flexible, Connectrac In-Carpet Wireways comply with the ADA and offer a multitude of power options and telecom capabilities. Connectrac is the best alternative for open space connectivity when aesthetics, flexibility and value are important. IN-CARPET WIREWAY FEATURES • Low-profile, durable extruded aluminum wireway • Moisture-resistant MDF floor transition ramps • Provides a cable pathway with no core drilling or trenching • Multitude of power and telecom/AV options • Pre-wired power components speed installation • Removable wireway top cap makes changing cables simple • ADA compliant • Multiple finishes available ES I N -C A RPET W IREWAY 08222014 1 AL GR C O NN ECTRA C.CO M IN -CA RPE T W I R EWAY CO M PO N E N TS PS-M-480 IN-EC † AC-WT-XX IN-048-XX* IN-096-XX* (required accessory) IN-048-XX* IN-096-XX* PS-I-288 IN-048-XX* IN-096-XX* IN-EC IN-C90-XX* (required accessory) BAS E S Y S TEM C OM PONENT S WIRE WAY S E G M E N T S AVA I L A B L E I N : • • 48” and 96” lengths - field-cut to required length and combined as necessary Top cap available in 3 finishes: Clear Anodized Aluminum (AL), Graphite (GR), Espresso (ES) E ACH S E G M E N T I N C L U D E S : • • • • Extruded Aluminum Wireway Base Track And Top Cap Moisture-Resistant MDF Floor Transition Ramps Wire Management Clips Concrete Screws And Drill Bit ALUMINUM TOP CAP MOISTURE-RESISTANT FLOOR TRANSITION RAMPS CONCRETE SCREWS WIRE MANAGEMENT CLIPS .87” 48”/ 96” ALUMINUM BOTTOM TRACK 15” 3.7” 15” PART NU M BE R D E SC R I PT I ON IN-048-XX* ..... . . . . . . . . . . . . . 4 8 ” S e g m e n t: 4 8 ” Wi r e w a y A n d Tr a n s i t i o n R a m p s IN-096-XX* ..... . . . . . . . . . . . . . 9 6 ” S e g m e n t: 9 6 ” Wi r e w a y A n d Tr a n s i t i o n R a m p s *Top Cap Finishes: Replace “XX” With “AL” (Clear Anodized Aluminum), “GR” (Graphite powder coat), or “ES” (Espresso powder coat) † Accessory Finishes: Replace “XX” With “BK” (Black) or “SV” (Silver) I N -C A RPET W IREWAY 08222014 2 C O NN ECTRA C.CO M WIREWAY C O M P O N ENTS A N D A CCE S S O R I E S BASE SYSTEM COMPONENTS: OPTIONAL ACCESSORIES: WIREWAY BOTTOM TRACK AND TOP CAP .4” TRANSITION ADAPTER • Used to transition cabling at beginning or • Bottom track anchors to slab end of wireway • Top cap snaps into bottom track 3.7” 1.5” • Extruded aluminum 3.75” • Available lengths: 48” / 96” • Snaps into wireway bottom track PN: AC-WT-BK (BLACK) PN: AC-WT-SV (SILVER) 2.1” INCLUDED IN EACH WIREWAY SEGMENT .7” GROMMET 3.7” .75” 2.6” • Adheres to slab with 3.75” construction adhesive • Moisture-resistant MDF • Available lengths: 48” / 96” .6” 15” • Allows cabling to enter / exit wireway • Snaps into wireway bottom track SIDE TRANSITION RAMPS PN: AC-GR-BK (BLACK) PN: AC-GR-SV (SILVER) INCLUDED IN EACH WIREWAY SEGMENT COMMUNICATION BOX • Steel low-voltage enclosure 3.5” REQUIRED ACCESSORY: • Accepts any standard double-gang faceplate • 3” available depth • Same profile as AV Duplex (page 5) END TRANSITION RAMPS 15” 5.4” 5.4” PN: IN-COM • Moisture-resistant MDF and molded ABS plastic .6” 15” PN: IN-EC 3.7” 12” 45˚ CORNER KIT* 12” • Pre-cut wireway components • Adds 24” to existing system 15” PN: IN-C45-XX* 90˚ CORNER KIT* 20” 20” • Pre-cut wireway components • Adds 40” to existing system PN: IN-C90-XX* 1.4” ROUGH-IN BOX • Optional component used in new wall 3.75” construction to transition cabling from wall cavity into wireway 2.6” PN: AC-RIB-1 *Top Cap Finishes: Replace “XX” With “AL” (Clear Anodized Aluminum), “GR” (Graphite powder coat), or “ES” (Espresso powder coat) I N -C A RPET W IREWAY 08222014 3 C O NN ECTRA C.CO M WIREWAY A C C ES S O RI E S 20” WALL CHANNEL SIDE ENTRY KIT* • Vertical wireway, surface-mounts to wall • Allows cabling to enter side of • 20” • • • wireway instead of end to provide path from Connectrac system at floor to surface-mounted junction box 20” long, can be trimmed to fit Includes 4”x4”x2.125” double-gang steel junction box, with silver powder coat Functions as extender ring for standard single gang outlet box Includes (2) AC-WT-SV and (1) AC-GR-SV • Adds 12” to existing system PN: IN-SE-1-XX* 12” PN: AC-WC-020-AL DOME COVER KIT 144” WALL CHANNEL 3” • Vertical wireway, surface-mounts to wall to provide path from Connectrac system at floor to ceiling above • 12’ / 144” Length • Includes (1) AC-WT-SV accessory 144” • Used to transition cabling to 18.6” 10.4” PN: AC-WC-144-AL Connectrac system from poke-through device • Integrates with standard side transition ramps PN: IN-DM *Top Cap Finishes: Replace “XX” With “AL” (Clear Anodized Aluminum), “GR” (Graphite powder coat), or “ES” (Espresso powder coat) I N -C A RPET W IREWAY 08222014 4 C O NN ECTRA C.CO M S INGLE IN GL E D DE E VIC VI C E P O W E R O PTI PT IO ONS DUPLEX (I S ERIES ) 1.1” 4.5” 7” 1.6” VARIES 3.1” INCLUDES: • Single 3-wire, 1-circuit NEMA 5-20R duplex receptacle • Attached pre-wired galvanized steel flex conduit; 3-wire / 1-circuit with 1/2” knockout fitting (length options below) • Black ABS plastic cover w/2 mounting screws • Modular data opening (see page 7) 4.75” PART NU M BE R D E SC RI PT I ON P S -I-144 ........... . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 144” In f e ed P S -I-288 .......... . . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 28 8” I nf eed P S -I-480 .......... . . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 48 0” I nf eed 5.4” AV DU PLEX INCLUDES: • Steel enclosure with access cover • Single 3-wire, 1-circuit NEMA 5-20R duplex receptacle • Attached pre-wired galvanized steel flex conduit; 3-wire / 1-circuit with1/2” knockout fitting (length options below) • Standard double gang telecom opening; 3” depth for installing AV plates/devices 3.5” 7.25” VARIES PART NU M BE R D E SC RI PT I ON P S -A-IN-144 ..... . . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 14 4” I nf eed P S -A-IN-288 ..... . . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 28 8” I nf eed P S -A-IN-480 ..... . . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 48 0” I nf eed 4-C IRC UIT MONUMENT (M S ER IES ) 3” 4.75” .75” 6” 3.1” .75” 3.1” VARIES INCLUDES: • Single 36.5 cubic inch steel electrical housing for hardwire connection, black powder coat • Attached pre-wired galvanized steel flex conduit; 8-wire / 4-circuit with 1/2” knockout fitting (length options below) • Pass-thru opening for telecom cabling • Refer to page 9 for wiring diagram options 3.1” PART NU M BE R D E SC RI PT I ON P S -M-288 ......... . . . . . . . . . . . 8 - wire , 4 - c irc uit b ox f or f ur ni t u r e h ar dwire; 288” inf eed P S -M-480 ......... . . . . . . . . . . . 8 - wire , 4 - c irc uit b ox f or f ur ni t u r e h ar dwir e; 480” inf eed N OT E : S E E MORE POWER O PTION S O N N E X T PAGE IN-CA RPET W IREWAY 12122014 5 CONNECTRAC.COM MO DULAR P O W ER O P TI O N S (U S E R I E S ) EMENTS 6” INCR PM-MODC-XXX PM-RECM-QD-XXXX PM-RECM-DP-X PM-JUMP-XXX M O DU L AR P O W E R SY S T E M S • • • 20Amp NEMA 5-20R duplex or quad receptacles; includes black ABS plastic cover, mounting screws, and two modular data openings (refer to page 8). Modular connections: multiple receptacle units can be connected using modular jumper and power infeed cables Receptacle devices are keyed to individual circuits. PM-RECM-DP-X: PM-RECM-QD-XXXX: 13.6” 13.3” 2” 1.5” 4.4” 4.4” 2” 2.6” 3.1” 3.1” 7” PART NU MBE R 7” D E S C R I PT I ON P M -MO DC-1 4 4 . . . . . . . . . . . . . . . . 8 - Wire Modul ar P o w e r I n f e e d , 1 4 4 ” L e n g t h P M -MO DC-2 8 8 . . . . . . . . . . . . . . . . 8 - Wire Modul ar P o w e r I n f e e d , 2 8 8 ” L e n g t h P M -MO DC-4 8 0 ................. 8 - Wire Modul ar P o w e r I n f e e d , 4 8 0 ” L e n g t h P M -R ECM -DP -1 .. . . . . . . . . . . . . . . Dupl e x Re c e pt a c l e ; B o t h O u t l e t s C k t 1 P M -R ECM -DP -2 ................. Dupl e x Re c e pt a c l e ; B o t h O u t l e t s C k t 2 P M -R ECM -DP -3 ................. Dupl e x Re c e pt a c l e ; B o t h O u t l e t s C k t 3 P M -R ECM -DP -4 ................. Dupl e x Re c e pt a c l e ; B o t h O u t l e t s C k t 4 P M -R ECM -Q D-1 1 1 1 . . . . . . . . . . Q ua d Re c e pt a c l e ; F o u r O u t l e t s C k t 1 P M -R ECM -Q D-2 2 2 2 . . . . . . . . . . Q ua d Re c e pt a c l e ; F o u r O u t l e t s C k t 2 P M -R ECM -Q D-3 3 3 3 . . . . . . . . . . Q ua d Re c e pt a c l e ; F o u r O u t l e t s C k t 3 P M -R ECM -Q D-4 4 4 4 . . . . . . . . . . Q ua d Re c e pt a c l e ; F o u r O u t l e t s C k t 4 P M -R ECM -Q D-1 1 2 2 . . . . . . . . . . Q ua d Re c e pt a c l e ; Tw o O u t l e t s C k t 1 , Tw o O u t l e t s C k t 2 P M -R ECM -Q D-3 3 4 4 . . . . . . . . . . Q ua d Re c e pt a c l e ; Tw o O u t l e t s C k t 3 , Tw o O u t l e t s C k t 4 PM-JUMP-024 .... . . . . . . . . . . . . . . Modul ar PM-JUMP-030 ... ................ Modul ar PM-JUMP-036 ................... Modul ar PM-JUMP-042 ... ................ Mod ul a r PM-JUMP-048 ... . . . . . . . . . . . . . . . Mod ul a r PM-JUMP-054 ... . . . . . . . . . . . . . . . Mod ul a r PM-JUMP-060 ... . . . . . . . . . . . . . . . Mod ul a r PM-JUMP-066 ... . . . . . . . . . . . . . . . Mod ul a r PM-JUMP-072 ... . . . . . . . . . . . . . . . Mod ul a r PM-JUMP-084 ... . . . . . . . . . . . . . . . Mod ul a r PM-JUMP-096 ... . . . . . . . . . . . . . . . Mod ul a r I N -C A RPET W IREWAY 08222014 J ump e r J ump e r J ump e r J umpe r J umpe r J umpe r J umpe r J umpe r J umpe r J umpe r J umpe r Ca b l e Ca b l e Ca b l e Cable Cable Cable Cable Cable Cable Cable Cable for for for for for for for for for for for 24” 30” 36” 42” 48” 54” 60” 66” 72” 84” 96” 6 On-Center On-Center On-Center On-Center On-Center On-Center On-Center On-Center On-Center On-Center On-Center Devices Devices Devices Devices Devices Devices Devices Devices Devices Devices Devices C O NN ECTRA C.CO M TELEC O M - S I N G LE D U PL E X S TANDARD T E L E C OM KI T The single duplex device incorporates a four-unit modular N 4-U telecom opening. Each device comes with two angled TC-UM03-BK EL IT T EC OPE OM NIN G modules from Hubbell that accomodate up to four keystone-sized connectors. These modules also accomodate keystone-sized connectors from a variety of other manufacturers. INC L U D E D M OD U L E S : • • • (2) TC-UM03-BK 1.5 unit 1-port angled modules (1) TC-BM01-BK .5 unit blank module (4) TC-BM02-BK 1.0 unit blank module These modules are included with each single duplex O P T I O NAL A U D I O/ V I SU A L KI T OPTIONAL V OIC E/DATA K IT INCLUDES: • (2) TC-KS01-BK Cat6 data jacks • (1) TC-KS08-BK HDMI keystone pass-thru • (1) TC-OC03-BK VGA gender changer – Includes TC-UM02-BK unloaded module – Includes 18” slimline VGA patch cable • (1) TC-KS10-BK 3.5mm audio screw termination jack INCLUDES: • (4) TC-KS01-BK Cat6 voice/data jacks PN: TKIT-VD1 PN: TKIT-AV1 NOTE: Both optional telecom kits utilize the (2) TC-UM03-BK modules included with each receptacle cover UNLO A DE D MO DU L ES PART NU MBE R D E SC R I PT I ON TC- UM 0 1 -BK .......... . . . . . . 1 .5 Un it A n g le d F o r VGA ( TC - OC 03) TC- UM 0 3 -BK .......... . . . . . . 1 .5 Un it A n g le d F o r (2 ) Ke y s t o ne C o nne ct o r s TC- UM 0 5 -BK .......... . . . . . . 1 .0 Un it F lat F o r (1 ) Ke yst o ne KE Y S TO N E CO NN EC T OR S PART NU MBE R D E SC R I PT I ON TC- K S01 -BK ............ . . . . . CAT 6 S n ap F it J ac k T C -K S 06-BL ............. . . . . . U SB Sn ap Fit P a ss- T h ru F/ F C o u p l e r, US B 2 . 0 A t o A TC- K S08 -BK ............ . . . . . HD M I S n ap F it Pas s -T h r u F / F C o u p l e r TC- K S09 -BK ............ . . . . . F -Co n n e c t o r S n ap F it Pass - Thr u F / F C o u p l e r TC- K S10 -BK ............ . . . . . 3 .5 M M A udio S n ap F it , S c r e w Te r mi na t i o n O THE R CO N N E CT OR S PART NU MBE R D E SC R I PT I ON TC- OC03 ............... . . . . . . VGA Ge n de r Ch an g e r, 1 5 - P I N F / F I N -C A RPET W IREWAY 08222014 7 C O NN ECTRA C.CO M TELEC O M - M O D U LA R P O W E R S TANDARD T E L E C OM KI T N 3-U Modular receptacle devices (duplex and quad) each incorporate 2 three-unit modular telecom openings. Each device comes with two TC-UM04-BK modules from Hubbell that accomodate up to four keystone-sized connectors. These modules also accomodate 3-U NIT TEL EC OPE OM NIN EL IT T EC OPE OM NIN G G keystone-sized connectors from a variety of other manufacturers. INC L U D E D M OD U L E S : • • (2) TC-UM04-BK 1.0 unit 2-port flat modules (6) TC-BM02-BK 1.0 unit blank module These modules are included with each duplex and quad modular receptacle O P T I ON A L V OI C E / D ATA KI T INCLUDES: • (4) TC-KS01-BK Cat6 voice/data jacks PN: TKIT-VD1 NOTE: The optional telecom kit utilizes the (2) TC-UM04-BK modules included with each receptacle cover UNL O A DE D M OD U L ES PART NU MBE R D E SC R I PT I ON TC-UM 0 1 -BK TC-UM 0 3 -BK TC-UM 0 4 -BK TC-UM 0 5 -BK .... . . . . . . . . . . . . 1 .5 .... . . . . . . . . . . . . 1 .5 .... . . . . . . . . . . . . 1 .0 .... . . . . . . . . . . . . 1 .0 Un it Un it Un it Un it A n g le d F o r A n g le d F o r F lat F o r (2 ) F lat F o r (1 ) VGA ( 2) K e y s t o ne C o nne ct o r s K e y s t o ne C o nne ct o r s K e y s t o ne C o nne ct o r K E YSTO N E CON N EC T OR S PART NU MBE R D E SC R I PT I ON TC-KS01 -BK ..... . . . . . . . . . . . . CAT 6 S n ap F it J ac k TC-KS 06-BL ...... . . . . . . . . . . . . U SB Sn a p Fit P ass- T hr u F / F C o u p l e r, US B 2 . 0 A t o A TC-KS08 -BK ..... . . . . . . . . . . . . HD M I S n ap F it Pas s -T hr u F / F C o u p l e r TC-KS09 -BK ..... . . . . . . . . . . . . F -Co n n e c t o r S n ap F it P a s s - Thr u F / F C o u p l e r TC-KS10 -BK ..... . . . . . . . . . . . . 3 .5 M M A udio S n ap F i t , S cr e w Te r mi na t i o n O THE R CO N N EC T OR S PART NU MBE R D E SC R I PT I ON TC-O C03 ......... . . . . . . . . . . . . VGA Ge n de r Ch an g e r, 15- P I N F / F I N -C A RPET W IREWAY 08222014 8 C O NN ECTRA C.CO M WIRING D I A G R A M S SINGLE DUPLEX RECEPTACLE SYSTEMS MODULAR RECEPTACLE SYSTEMS PS-I-XXX, PS-A-IN-XXX PM-RECM-DP-X, PM-RECM-QD-XXXX WHITE NEUTRAL (12 gauge) GREEN GROUND (12 gauge) BLACK HOT (12 gauge) CIRCUIT ONE CIRCUIT TWO CIRCUIT THREE I II III CIRCUIT FOUR (ISOLATED) IV NEUTRAL 2 GRAY 12 GAUGE NEUTRAL 1 WHITE 10 GAUGE GRN-YEL 12 GAUGE GREEN 12 GAUGE HOT 4 PINK 12 GAUGE HOT 3 BLUE 12 GAUGE HOT 2 RED 12 GAUGE HOT 1 BLACK 12 GAUGE ISO GROUND GROUND 4-CIRCUIT CONNECTION MONUMENT PM-M-XXX 3+1 W I R I NG O P T I O N : 2+2 W I R I N G OP TI ON : CIRCUIT ONE CIRCUIT TWO CIRCUIT THREE I II III CIRCUIT FOUR (ISOLATED) CIRCUIT ONE CIRCUIT TWO CIRCUIT THREE CIRCUIT FOUR IV I II III IV NEUTRAL 2 GRAY 12 GAUGE NEUTRAL 2 GRAY 12 GAUGE NEUTRAL 1 WHITE 10 GAUGE NEUTRAL 1 WHITE 10 GAUGE GRN-YEL 12 GAUGE ISO GROUND GRN-YEL 12 GAUGE GREEN 12 GAUGE GROUND GREEN 12 GAUGE HOT 4 PINK 12 GAUGE HOT 4 PINK 12 GAUGE HOT 3 BLUE 12 GAUGE HOT 3 BLUE 12 GAUGE HOT 2 RED 12 GAUGE HOT 2 RED 12 GAUGE HOT 1 BLACK 12 GAUGE HOT 1 BLACK 12 GAUGE ISO GROUND GROUND NOTE: The 4-circuit connection monument can utilize either of the above wiring schemes CABLE FILL CAPACITY Voice / Data / AV cabling can be placed alongside power in I NSI D E D I MENSI ONS: 3 .1 ” x .6 ” the wireway channel. Shielding for the low voltage cabling is provided by Connectrac’s special steel flex conduit. S TA N D A R D FI L L C A PA C I T I E S: Cat 5e Cat 6 Cat 6a Cable OD (varies by manufacturer) .21” .25” .354” Cable cross sectional area .035” .035” .035” Max cables in wireway with power conduit 25 18 * * The number of Cat 6A cables must be determined by the communications system designer due to the special installation requirements of Cat 6A cables. I N -C A RPET W IREWAY 08222014 9 C O NN ECTRA C.CO M CONNECTRAC LIMITED WARRANTY Strong Products Group, Ltd. d/b/a Connectrac (“Connectrac”) hereby warrants, to the original purchaser or owner (collectively, “Buyer”), that any product manufactured and sold by Connectrac will be substantially free from unreasonable and significant defects in material, construction, and workmanship under normal use, service, and only for their original purpose, for a period of five (5) years from the date of original installation or six (6) years from the date of purchase, whichever is sooner. Standard commercial tolerances apply. This Limited Warranty (“Statement”) applies only to products, which have been installed properly in accordance with Installation Instructions supplied by Connectrac and any applicable codes and standards. This Statement is void if any Connectrac products have been modified, repaired, altered, tampered, mixed with, or intermixed (used within a system) with products or materials in a manner not approved by Connectrac. This Statement does not cover Connectrac products subjected to accidents, improper use, improper maintenance, improper cleaning, negligence, misuse, or abuse. This Statement is void if damage results from the use of detergents, cleaners, abrasives, or other harsh chemical agents not authorized or sanctioned by Connectrac. Connectrac is in no way liable or responsible for any damage to Connectrac products that would void this Statement. When you contact Connectrac, please provide reasonable proof of the date of your purchase of the Connectrac product at issue. It may be necessary for Connectrac to arrange an inspection of your product to determine whether or not a defect exists. Connectrac’s sole obligation (and the sole exclusive remedy of the Buyer) with respect to any products that are proven to be defective, will, at the sole discretion of Connectrac, be the repair or replacement of the defective products or refund of the purchase price of the defective products. Returned products will not be accepted unless Connectrac is notified and authorizes the return, in writing, prior to shipment. Certain products of Connectrac may have a specific limited warranty or limitation of liability included that differs from this Statement. The terms of any such specific limited warranty or limitation of liability supersede those set forth in this Statement. Connectrac’s products are listed by Underwriters Laboratories, Inc. and the Canadian Standards Association. Buyer agrees to exercise reasonable care in the installation and use of Connectrac products. Buyer acknowledges that Connectrac products may be dangerous and agrees to release Connectrac from any liability for injury or damage in connection therewith. Buyer further agrees to defend, indemnify, and hold harmless Connectrac from and against any and all third-party claims and liabilities (including, without limitation, reasonable attorneys’ fees and costs), regardless of the form of action, arising out of or in connection with the installation and use of Connectrac products, provided that Buyer is notified promptly in writing of the action, Connectrac has not reached any compromise or settlement of such action or made any admissions in respect of the same, and Buyer is given the option, at its expense, to control the action and all requested reasonable assistance, including indemnification from any third party, to defend the same. I N -C A RPET W IREWAY 08222014 10 C O NN ECTRA C.CO M