In-Carpet Specification Guide

Transcription

In-Carpet Specification Guide
I N - C A R P E T W I R E WAY
ARCHITECTURAL SOLUTIONS FOR OPEN SPACE POWER AND CONNECTIVITY
Connectrac In-Carpet Wireways offer discrete and elegant power and technology connectivity in open interior spaces
of all kinds. They combine an extruded aluminum central wireway flanked by ultra-low sloping floor transition ramps,
creating a subtle, powerful and beautiful cable pathway solution for virtually any need. Extremely durable and flexible,
Connectrac In-Carpet Wireways comply with the ADA and offer a multitude of power options and telecom capabilities.
Connectrac is the best alternative for open space connectivity when aesthetics, flexibility and value are important.
IN-CARPET WIREWAY FEATURES
• Low-profile, durable extruded aluminum wireway
• Moisture-resistant MDF floor transition ramps
• Provides a cable pathway with no core drilling or trenching
• Multitude of power and telecom/AV options
• Pre-wired power components speed installation
• Removable wireway top cap makes changing cables simple
• ADA compliant
• Multiple finishes available
ES
I N -C A RPET W IREWAY
08222014
1
AL
GR
C O NN ECTRA C.CO M
IN -CA RPE T W I R EWAY CO M PO N E N TS
PS-M-480
IN-EC
†
AC-WT-XX
IN-048-XX*
IN-096-XX*
(required accessory)
IN-048-XX*
IN-096-XX*
PS-I-288
IN-048-XX*
IN-096-XX*
IN-EC
IN-C90-XX*
(required accessory)
BAS E S Y S TEM C OM PONENT S
WIRE WAY S E G M E N T S AVA I L A B L E I N :
•
•
48” and 96” lengths - field-cut to required length and combined as necessary
Top cap available in 3 finishes: Clear Anodized Aluminum (AL), Graphite (GR), Espresso (ES)
E ACH S E G M E N T I N C L U D E S :
•
•
•
•
Extruded Aluminum Wireway Base Track And Top Cap
Moisture-Resistant MDF Floor Transition Ramps
Wire Management Clips
Concrete Screws And Drill Bit
ALUMINUM TOP CAP
MOISTURE-RESISTANT
FLOOR TRANSITION
RAMPS
CONCRETE SCREWS
WIRE MANAGEMENT
CLIPS
.87”
48”/ 96”
ALUMINUM BOTTOM
TRACK
15”
3.7”
15”
PART NU M BE R
D E SC R I PT I ON
IN-048-XX* ..... . . . . . . . . . . . . . 4 8 ” S e g m e n t: 4 8 ” Wi r e w a y A n d Tr a n s i t i o n R a m p s
IN-096-XX* ..... . . . . . . . . . . . . . 9 6 ” S e g m e n t: 9 6 ” Wi r e w a y A n d Tr a n s i t i o n R a m p s
*Top Cap Finishes: Replace “XX” With “AL” (Clear Anodized Aluminum), “GR” (Graphite powder coat), or “ES” (Espresso powder coat)
†
Accessory Finishes: Replace “XX” With “BK” (Black) or “SV” (Silver)
I N -C A RPET W IREWAY
08222014
2
C O NN ECTRA C.CO M
WIREWAY C O M P O N ENTS A N D A CCE S S O R I E S
BASE SYSTEM COMPONENTS:
OPTIONAL ACCESSORIES:
WIREWAY BOTTOM TRACK
AND TOP CAP
.4”
TRANSITION ADAPTER
• Used to transition cabling at beginning or
• Bottom track anchors to slab
end of wireway
• Top cap snaps into bottom track
3.7”
1.5”
• Extruded aluminum
3.75”
• Available lengths: 48” / 96”
• Snaps into wireway bottom track
PN: AC-WT-BK (BLACK)
PN: AC-WT-SV (SILVER)
2.1”
INCLUDED IN EACH WIREWAY SEGMENT
.7”
GROMMET
3.7”
.75”
2.6”
• Adheres to slab with
3.75”
construction adhesive
• Moisture-resistant MDF
• Available lengths: 48” / 96”
.6”
15”
• Allows cabling to enter / exit wireway
• Snaps into wireway bottom track
SIDE TRANSITION RAMPS
PN: AC-GR-BK (BLACK)
PN: AC-GR-SV (SILVER)
INCLUDED IN EACH WIREWAY SEGMENT
COMMUNICATION BOX
• Steel low-voltage enclosure
3.5”
REQUIRED ACCESSORY:
• Accepts any standard double-gang faceplate
• 3” available depth
• Same profile as AV Duplex (page 5)
END TRANSITION RAMPS
15”
5.4”
5.4”
PN: IN-COM
• Moisture-resistant MDF and
molded ABS plastic
.6”
15”
PN: IN-EC
3.7”
12”
45˚ CORNER KIT*
12”
• Pre-cut wireway components
• Adds 24” to existing system
15”
PN: IN-C45-XX*
90˚ CORNER KIT*
20”
20”
• Pre-cut wireway components
• Adds 40” to existing system
PN: IN-C90-XX*
1.4”
ROUGH-IN BOX
• Optional component used in new wall
3.75”
construction to transition cabling from wall
cavity into wireway
2.6”
PN: AC-RIB-1
*Top Cap Finishes: Replace “XX” With “AL” (Clear Anodized Aluminum), “GR” (Graphite powder coat), or “ES” (Espresso powder coat)
I N -C A RPET W IREWAY
08222014
3
C O NN ECTRA C.CO M
WIREWAY A C C ES S O RI E S
20” WALL CHANNEL
SIDE ENTRY KIT*
• Vertical wireway, surface-mounts to wall
• Allows cabling to enter side of
•
20”
•
•
•
wireway instead of end
to provide path from Connectrac system at
floor to surface-mounted junction box
20” long, can be trimmed to fit
Includes 4”x4”x2.125” double-gang steel
junction box, with silver powder coat
Functions as extender ring for standard
single gang outlet box
Includes (2) AC-WT-SV and (1) AC-GR-SV
• Adds 12” to existing system
PN: IN-SE-1-XX*
12”
PN: AC-WC-020-AL
DOME COVER KIT
144” WALL CHANNEL
3”
• Vertical wireway, surface-mounts to wall
to provide path from Connectrac system at
floor to ceiling above
• 12’ / 144” Length
• Includes (1) AC-WT-SV accessory
144”
• Used to transition cabling to
18.6”
10.4”
PN: AC-WC-144-AL
Connectrac system from poke-through
device
• Integrates with standard side
transition ramps
PN: IN-DM
*Top Cap Finishes: Replace “XX” With “AL” (Clear Anodized Aluminum), “GR” (Graphite powder coat), or “ES” (Espresso powder coat)
I N -C A RPET W IREWAY
08222014
4
C O NN ECTRA C.CO M
S INGLE
IN GL E D
DE
E VIC
VI C E P O W E R O PTI
PT IO
ONS
DUPLEX (I S ERIES )
1.1”
4.5”
7”
1.6”
VARIES
3.1”
INCLUDES:
• Single 3-wire, 1-circuit NEMA 5-20R duplex receptacle
• Attached pre-wired galvanized steel flex conduit; 3-wire / 1-circuit
with 1/2” knockout fitting (length options below)
• Black ABS plastic cover w/2 mounting screws
• Modular data opening (see page 7)
4.75”
PART NU M BE R
D E SC RI PT I ON
P S -I-144 ........... . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 144” In f e ed
P S -I-288 .......... . . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 28 8” I nf eed
P S -I-480 .......... . . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 48 0” I nf eed
5.4”
AV DU PLEX
INCLUDES:
• Steel enclosure with access cover
• Single 3-wire, 1-circuit NEMA 5-20R duplex receptacle
• Attached pre-wired galvanized steel flex conduit; 3-wire / 1-circuit
with1/2” knockout fitting (length options below)
• Standard double gang telecom opening; 3” depth for installing
AV plates/devices
3.5”
7.25”
VARIES
PART NU M BE R
D E SC RI PT I ON
P S -A-IN-144 ..... . . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 14 4” I nf eed
P S -A-IN-288 ..... . . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 28 8” I nf eed
P S -A-IN-480 ..... . . . . . . . . . . . . 2 0 Amp d upl e x re c e p t ac l e ; 48 0” I nf eed
4-C IRC UIT MONUMENT (M S ER IES )
3”
4.75”
.75”
6”
3.1”
.75”
3.1”
VARIES
INCLUDES:
• Single 36.5 cubic inch steel electrical housing for hardwire
connection, black powder coat
• Attached pre-wired galvanized steel flex conduit; 8-wire / 4-circuit
with 1/2” knockout fitting (length options below)
• Pass-thru opening for telecom cabling
• Refer to page 9 for wiring diagram options
3.1”
PART NU M BE R
D E SC RI PT I ON
P S -M-288 ......... . . . . . . . . . . . 8 - wire , 4 - c irc uit b ox f or f ur ni t u r e h ar dwire; 288” inf eed
P S -M-480 ......... . . . . . . . . . . . 8 - wire , 4 - c irc uit b ox f or f ur ni t u r e h ar dwir e; 480” inf eed
N OT E : S E E MORE POWER O PTION S O N N E X T PAGE
IN-CA RPET W IREWAY
12122014
5
CONNECTRAC.COM
MO DULAR P O W ER O P TI O N S (U S E R I E S )
EMENTS
6” INCR
PM-MODC-XXX
PM-RECM-QD-XXXX
PM-RECM-DP-X
PM-JUMP-XXX
M O DU L AR P O W E R SY S T E M S
•
•
•
20Amp NEMA 5-20R duplex or quad receptacles; includes black ABS plastic cover, mounting screws, and two
modular data openings (refer to page 8).
Modular connections: multiple receptacle units can be connected using modular jumper and power infeed cables
Receptacle devices are keyed to individual circuits.
PM-RECM-DP-X:
PM-RECM-QD-XXXX:
13.6”
13.3”
2”
1.5”
4.4”
4.4”
2”
2.6”
3.1”
3.1”
7”
PART NU MBE R
7”
D E S C R I PT I ON
P M -MO DC-1 4 4 . . . . . . . . . . . . . . . . 8 - Wire Modul ar P o w e r I n f e e d , 1 4 4 ” L e n g t h
P M -MO DC-2 8 8 . . . . . . . . . . . . . . . . 8 - Wire Modul ar P o w e r I n f e e d , 2 8 8 ” L e n g t h
P M -MO DC-4 8 0 ................. 8 - Wire Modul ar P o w e r I n f e e d , 4 8 0 ” L e n g t h
P M -R ECM -DP -1 .. . . . . . . . . . . . . . . Dupl e x Re c e pt a c l e ; B o t h O u t l e t s C k t 1
P M -R ECM -DP -2 ................. Dupl e x Re c e pt a c l e ; B o t h O u t l e t s C k t 2
P M -R ECM -DP -3 ................. Dupl e x Re c e pt a c l e ; B o t h O u t l e t s C k t 3
P M -R ECM -DP -4 ................. Dupl e x Re c e pt a c l e ; B o t h O u t l e t s C k t 4
P M -R ECM -Q D-1 1 1 1 . . . . . . . . . . Q ua d Re c e pt a c l e ; F o u r O u t l e t s C k t 1
P M -R ECM -Q D-2 2 2 2 . . . . . . . . . . Q ua d Re c e pt a c l e ; F o u r O u t l e t s C k t 2
P M -R ECM -Q D-3 3 3 3 . . . . . . . . . . Q ua d Re c e pt a c l e ; F o u r O u t l e t s C k t 3
P M -R ECM -Q D-4 4 4 4 . . . . . . . . . . Q ua d Re c e pt a c l e ; F o u r O u t l e t s C k t 4
P M -R ECM -Q D-1 1 2 2 . . . . . . . . . . Q ua d Re c e pt a c l e ; Tw o O u t l e t s C k t 1 , Tw o O u t l e t s C k t 2
P M -R ECM -Q D-3 3 4 4 . . . . . . . . . . Q ua d Re c e pt a c l e ; Tw o O u t l e t s C k t 3 , Tw o O u t l e t s C k t 4
PM-JUMP-024 .... . . . . . . . . . . . . . . Modul ar
PM-JUMP-030 ... ................ Modul ar
PM-JUMP-036 ................... Modul ar
PM-JUMP-042 ... ................ Mod ul a r
PM-JUMP-048 ... . . . . . . . . . . . . . . . Mod ul a r
PM-JUMP-054 ... . . . . . . . . . . . . . . . Mod ul a r
PM-JUMP-060 ... . . . . . . . . . . . . . . . Mod ul a r
PM-JUMP-066 ... . . . . . . . . . . . . . . . Mod ul a r
PM-JUMP-072 ... . . . . . . . . . . . . . . . Mod ul a r
PM-JUMP-084 ... . . . . . . . . . . . . . . . Mod ul a r
PM-JUMP-096 ... . . . . . . . . . . . . . . . Mod ul a r
I N -C A RPET W IREWAY
08222014
J ump e r
J ump e r
J ump e r
J umpe r
J umpe r
J umpe r
J umpe r
J umpe r
J umpe r
J umpe r
J umpe r
Ca b l e
Ca b l e
Ca b l e
Cable
Cable
Cable
Cable
Cable
Cable
Cable
Cable
for
for
for
for
for
for
for
for
for
for
for
24”
30”
36”
42”
48”
54”
60”
66”
72”
84”
96”
6
On-Center
On-Center
On-Center
On-Center
On-Center
On-Center
On-Center
On-Center
On-Center
On-Center
On-Center
Devices
Devices
Devices
Devices
Devices
Devices
Devices
Devices
Devices
Devices
Devices
C O NN ECTRA C.CO M
TELEC O M - S I N G LE D U PL E X
S TANDARD T E L E C OM KI T
The single duplex device incorporates a four-unit modular
N
4-U
telecom opening. Each device comes with two angled TC-UM03-BK
EL
IT T
EC
OPE
OM
NIN
G
modules from Hubbell that accomodate up to four keystone-sized
connectors. These modules also accomodate keystone-sized
connectors from a variety of other manufacturers.
INC L U D E D M OD U L E S :
•
•
•
(2) TC-UM03-BK 1.5 unit 1-port angled modules
(1) TC-BM01-BK .5 unit blank module
(4) TC-BM02-BK 1.0 unit blank module
These modules are included with each single duplex
O P T I O NAL A U D I O/ V I SU A L KI T
OPTIONAL V OIC E/DATA K IT
INCLUDES:
• (2) TC-KS01-BK Cat6 data jacks
• (1) TC-KS08-BK HDMI keystone pass-thru
• (1) TC-OC03-BK VGA gender changer
– Includes TC-UM02-BK unloaded module
– Includes 18” slimline VGA patch cable
• (1) TC-KS10-BK 3.5mm audio screw termination jack
INCLUDES:
• (4) TC-KS01-BK Cat6 voice/data jacks
PN: TKIT-VD1
PN: TKIT-AV1
NOTE: Both optional telecom kits utilize the (2) TC-UM03-BK modules included with each receptacle cover
UNLO A DE D MO DU L ES
PART NU MBE R
D E SC R I PT I ON
TC- UM 0 1 -BK .......... . . . . . . 1 .5 Un it A n g le d F o r VGA ( TC - OC 03)
TC- UM 0 3 -BK .......... . . . . . . 1 .5 Un it A n g le d F o r (2 ) Ke y s t o ne C o nne ct o r s
TC- UM 0 5 -BK .......... . . . . . . 1 .0 Un it F lat F o r (1 ) Ke yst o ne
KE Y S TO N E CO NN EC T OR S
PART NU MBE R
D E SC R I PT I ON
TC- K S01 -BK ............ . . . . . CAT 6 S n ap F it J ac k
T C -K S 06-BL ............. . . . . . U SB Sn ap Fit P a ss- T h ru F/ F C o u p l e r, US B 2 . 0 A t o A
TC- K S08 -BK ............ . . . . . HD M I S n ap F it Pas s -T h r u F / F C o u p l e r
TC- K S09 -BK ............ . . . . . F -Co n n e c t o r S n ap F it Pass - Thr u F / F C o u p l e r
TC- K S10 -BK ............ . . . . . 3 .5 M M A udio S n ap F it , S c r e w Te r mi na t i o n
O THE R CO N N E CT OR S
PART NU MBE R
D E SC R I PT I ON
TC- OC03 ............... . . . . . . VGA Ge n de r Ch an g e r, 1 5 - P I N F / F
I N -C A RPET W IREWAY
08222014
7
C O NN ECTRA C.CO M
TELEC O M - M O D U LA R P O W E R
S TANDARD T E L E C OM KI T
N
3-U
Modular receptacle devices (duplex and quad) each incorporate
2 three-unit modular telecom openings. Each device comes with
two TC-UM04-BK modules from Hubbell that accomodate up to
four keystone-sized connectors. These modules also accomodate
3-U
NIT
TEL
EC
OPE
OM
NIN
EL
IT T
EC
OPE
OM
NIN
G
G
keystone-sized connectors from a variety of other manufacturers.
INC L U D E D M OD U L E S :
•
•
(2) TC-UM04-BK 1.0 unit 2-port flat modules
(6) TC-BM02-BK 1.0 unit blank module
These modules are included with each duplex
and quad modular receptacle
O P T I ON A L V OI C E / D ATA KI T
INCLUDES:
• (4) TC-KS01-BK Cat6 voice/data jacks
PN: TKIT-VD1
NOTE: The optional telecom kit utilizes the (2) TC-UM04-BK modules included with each receptacle cover
UNL O A DE D M OD U L ES
PART NU MBE R
D E SC R I PT I ON
TC-UM 0 1 -BK
TC-UM 0 3 -BK
TC-UM 0 4 -BK
TC-UM 0 5 -BK
.... . . . . . . . . . . . . 1 .5
.... . . . . . . . . . . . . 1 .5
.... . . . . . . . . . . . . 1 .0
.... . . . . . . . . . . . . 1 .0
Un it
Un it
Un it
Un it
A n g le d F o r
A n g le d F o r
F lat F o r (2 )
F lat F o r (1 )
VGA
( 2) K e y s t o ne C o nne ct o r s
K e y s t o ne C o nne ct o r s
K e y s t o ne C o nne ct o r
K E YSTO N E CON N EC T OR S
PART NU MBE R
D E SC R I PT I ON
TC-KS01 -BK ..... . . . . . . . . . . . . CAT 6 S n ap F it J ac k
TC-KS 06-BL ...... . . . . . . . . . . . . U SB Sn a p Fit P ass- T hr u F / F C o u p l e r, US B 2 . 0 A t o A
TC-KS08 -BK ..... . . . . . . . . . . . . HD M I S n ap F it Pas s -T hr u F / F C o u p l e r
TC-KS09 -BK ..... . . . . . . . . . . . . F -Co n n e c t o r S n ap F it P a s s - Thr u F / F C o u p l e r
TC-KS10 -BK ..... . . . . . . . . . . . . 3 .5 M M A udio S n ap F i t , S cr e w Te r mi na t i o n
O THE R CO N N EC T OR S
PART NU MBE R
D E SC R I PT I ON
TC-O C03 ......... . . . . . . . . . . . . VGA Ge n de r Ch an g e r, 15- P I N F / F
I N -C A RPET W IREWAY
08222014
8
C O NN ECTRA C.CO M
WIRING D I A G R A M S
SINGLE DUPLEX RECEPTACLE SYSTEMS
MODULAR RECEPTACLE SYSTEMS
PS-I-XXX, PS-A-IN-XXX
PM-RECM-DP-X, PM-RECM-QD-XXXX
WHITE
NEUTRAL (12 gauge)
GREEN
GROUND (12 gauge)
BLACK
HOT (12 gauge)
CIRCUIT
ONE
CIRCUIT
TWO
CIRCUIT
THREE
I
II
III
CIRCUIT
FOUR
(ISOLATED)
IV
NEUTRAL 2
GRAY
12 GAUGE
NEUTRAL 1
WHITE
10 GAUGE
GRN-YEL
12 GAUGE
GREEN
12 GAUGE
HOT 4
PINK
12 GAUGE
HOT 3
BLUE
12 GAUGE
HOT 2
RED
12 GAUGE
HOT 1
BLACK
12 GAUGE
ISO GROUND
GROUND
4-CIRCUIT CONNECTION MONUMENT
PM-M-XXX
3+1 W I R I NG O P T I O N :
2+2 W I R I N G OP TI ON :
CIRCUIT
ONE
CIRCUIT
TWO
CIRCUIT
THREE
I
II
III
CIRCUIT
FOUR
(ISOLATED)
CIRCUIT
ONE
CIRCUIT
TWO
CIRCUIT
THREE
CIRCUIT
FOUR
IV
I
II
III
IV
NEUTRAL 2
GRAY
12 GAUGE
NEUTRAL 2
GRAY
12 GAUGE
NEUTRAL 1
WHITE
10 GAUGE
NEUTRAL 1
WHITE
10 GAUGE
GRN-YEL
12 GAUGE
ISO GROUND
GRN-YEL
12 GAUGE
GREEN
12 GAUGE
GROUND
GREEN
12 GAUGE
HOT 4
PINK
12 GAUGE
HOT 4
PINK
12 GAUGE
HOT 3
BLUE
12 GAUGE
HOT 3
BLUE
12 GAUGE
HOT 2
RED
12 GAUGE
HOT 2
RED
12 GAUGE
HOT 1
BLACK
12 GAUGE
HOT 1
BLACK
12 GAUGE
ISO GROUND
GROUND
NOTE: The 4-circuit connection monument can utilize either of the above wiring schemes
CABLE FILL CAPACITY
Voice / Data / AV cabling can be placed alongside power in
I NSI D E D I MENSI ONS:
3 .1 ” x .6 ”
the wireway channel. Shielding for the low voltage cabling is
provided by Connectrac’s special steel flex conduit.
S TA N D A R D FI L L C A PA C I T I E S:
Cat 5e
Cat 6
Cat 6a
Cable OD (varies by manufacturer)
.21”
.25”
.354”
Cable cross sectional area
.035”
.035”
.035”
Max cables in wireway with power conduit
25
18
*
* The number of Cat 6A cables must be determined by the communications system designer due to
the special installation requirements of Cat 6A cables.
I N -C A RPET W IREWAY
08222014
9
C O NN ECTRA C.CO M
CONNECTRAC LIMITED WARRANTY
Strong Products Group, Ltd. d/b/a Connectrac (“Connectrac”) hereby warrants, to the original purchaser or owner (collectively, “Buyer”),
that any product manufactured and sold by Connectrac will be substantially free from unreasonable and significant defects in material, construction,
and workmanship under normal use, service, and only for their original purpose, for a period of five (5) years from the date of original installation
or six (6) years from the date of purchase, whichever is sooner. Standard commercial tolerances apply. This Limited Warranty (“Statement”) applies
only to products, which have been installed properly in accordance with Installation Instructions supplied by Connectrac and any applicable codes and
standards.
This Statement is void if any Connectrac products have been modified, repaired, altered, tampered, mixed with, or intermixed (used within a system)
with products or materials in a manner not approved by Connectrac. This Statement does not cover Connectrac products subjected to accidents,
improper use, improper maintenance, improper cleaning, negligence, misuse, or abuse. This Statement is void if damage results from the use of
detergents, cleaners, abrasives, or other harsh chemical agents not authorized or sanctioned by Connectrac. Connectrac is in no way liable or
responsible for any damage to Connectrac products that would void this Statement.
When you contact Connectrac, please provide reasonable proof of the date of your purchase of the Connectrac product at issue. It may be necessary
for Connectrac to arrange an inspection of your product to determine whether or not a defect exists. Connectrac’s sole obligation (and the sole exclusive
remedy of the Buyer) with respect to any products that are proven to be defective, will, at the sole discretion of Connectrac, be the repair or replacement
of the defective products or refund of the purchase price of the defective products. Returned products will not be accepted unless Connectrac is notified
and authorizes the return, in writing, prior to shipment.
Certain products of Connectrac may have a specific limited warranty or limitation of liability included that differs from this Statement.
The terms of any such specific limited warranty or limitation of liability supersede those set forth in this Statement.
Connectrac’s products are listed by Underwriters Laboratories, Inc. and the Canadian Standards Association. Buyer agrees to exercise reasonable care
in the installation and use of Connectrac products. Buyer acknowledges that Connectrac products may be dangerous and agrees to release Connectrac
from any liability for injury or damage in connection therewith. Buyer further agrees to defend, indemnify, and hold harmless Connectrac from and
against any and all third-party claims and liabilities (including, without limitation, reasonable attorneys’ fees and costs), regardless of the form of action,
arising out of or in connection with the installation and use of Connectrac products, provided that Buyer is notified promptly in writing of the action,
Connectrac has not reached any compromise or settlement of such action or made any admissions in respect of the same, and Buyer is given the option,
at its expense, to control the action and all requested reasonable assistance, including indemnification from any third party, to defend the same.
I N -C A RPET W IREWAY
08222014
10
C O NN ECTRA C.CO M