Digital Indicator Data Sheet
Transcription
Digital Indicator Data Sheet
Electronic Temperature Measurement Loop Powered Indicator ATEX Model DLI APPROVED PRODUCTS Data sheet : DLI/2012 yy yy yy yy yy yy yy yy yy yy Loop powered Less than 1V required from loop ATEX approved for us in IS loops IP68 enclosure available Field programmable Wide range of Zero offsets RFI protected 12.5mm high display Operating temperature -10 to +70ºC Low cost General Description DLI is a loop powered digital indicator, which can be connected in series with any 4-20mA current loop and will display the current flowing in meaningful engineering units. The large 3 ½ digit display is easy to read and the whole device introduces a volt drop of less than 1V at full scale, which means it can be used where several other devices are already in the loop. The Zero and span are adjustable so the indicator can be can be calibrated to display any range within the +/-1999 range, large positive and negative zero offsets are easily accommodated. The DLI can be housed in an extended H70 head with an window lid which allows a transmitter and indicator to be conveniently mounted as a single unit. The model is available as a ATEX approved II 1G EExia IIC T5 version. Housings The indicator can be supplied in an EEx de approved, IP68 enclosure in a variety of materials to suit the needs of the environment in which it is installed. Extended versions allow a transmitter and indicator to be conveniently mounted as a single unit. Specification Input 4-20 mA 2 wire Display 3.5 digit LCD. Height 12.5 mm Volt Drop Less than 1V at 20mA Overrange ±200mA without damage Rangeability Zero can be set between -1300 & +1999 Span is fully adjustable ±1999 Method, by DIP switches and multi-turn potentiometers Decimal Point Selectable by DIP switch Accuracy ±1 digit DLI Versions Type Description ATEX Certificate Ambient Temperature Enclosed Unit (Standard) This model of the DLI is the ATEX certified version when fitted in the H70 connection head BAS00ATEX1160X -10 +50°C Non-Enclosed Unit This model of the DLI is the ATEX certified version used when supplied without connection head and probe transmitter assembly BAS00ATEX1161X -10 +70°C Uncertified This model of the DLI is the uncertified version used in weatherproof assemblies N/A -10 +70°C Excellence the World can Measure TM DLI1 Dimensions DLI1 Connection Diagram TM DLI - Ordering Code Model DLI DLI Type Enclosed Non-Enclosed Uncertified E N U Range Enter Minimum Range (Negative starts with N) XXXX Enter maximum Range (Positive starts with P) XXXX Unit of Measure Degree C (ºC) Degree F (ºF) C F Example Order Code yy yy yy yy yy DLI E DLI Enclosed Unit -100 Minimum Temperature +200 Minimum Temperature Deg C N0100 P0100 C TM ISO9001:2008 British Rototherm Company Limited Kenfig Industrial Estate, Margam, Port Talbot SA13 2PW United Kingdom Excellence the World can Measure TM T: +44 (0) 1656 740 551 E: [email protected] F: +44 (0) 1656 745 915 W: www.rotothermgroup.com In keeping with British Rototherm’s policy for continual product development and improvement, we reserve the right to amend specifications without notice. ©2012 Rototherm Group. All rights reserved. Company registered in Wales : 2570730. Registered office as above.