Digital Indicator Data Sheet

Transcription

Digital Indicator Data Sheet
Electronic Temperature
Measurement
Loop Powered Indicator
ATEX
Model DLI
APPROVED PRODUCTS
Data sheet : DLI/2012
yy
yy
yy
yy
yy
yy
yy
yy
yy
yy
Loop powered
Less than 1V required from loop
ATEX approved for us in IS loops
IP68 enclosure available
Field programmable
Wide range of Zero offsets
RFI protected
12.5mm high display
Operating temperature -10 to +70ºC
Low cost
General Description
DLI is a loop powered digital indicator, which can be connected in
series with any 4-20mA current loop and will display the current flowing in meaningful engineering units. The large 3 ½ digit display is easy
to read and the whole device introduces a volt drop of less than 1V at
full scale, which means it can be used where several other devices are
already in the loop.
The Zero and span are adjustable so the indicator can be can be calibrated to display any range within the +/-1999 range, large positive
and negative zero offsets are easily accommodated. The DLI can be
housed in an extended H70 head with an window lid which allows a
transmitter and indicator to be conveniently mounted as a single unit.
The model is available as a ATEX approved II 1G EExia IIC T5 version.
Housings
The indicator can be supplied in an EEx de approved, IP68 enclosure in
a variety of materials to suit the needs of the environment in which it
is installed. Extended versions allow a transmitter and indicator to be
conveniently mounted as a single unit.
Specification
Input
4-20 mA 2 wire
Display
3.5 digit LCD. Height 12.5 mm
Volt Drop
Less than 1V at 20mA
Overrange
±200mA without damage
Rangeability
Zero can be set between -1300 & +1999
Span is fully adjustable ±1999
Method, by DIP switches and multi-turn potentiometers
Decimal Point
Selectable by DIP switch
Accuracy
±1 digit
DLI Versions
Type
Description
ATEX Certificate
Ambient Temperature
Enclosed Unit (Standard)
This model of the DLI is the ATEX certified version
when fitted in the H70 connection head
BAS00ATEX1160X
-10 +50°C
Non-Enclosed Unit
This model of the DLI is the ATEX certified version
used when supplied without connection head
and probe transmitter assembly
BAS00ATEX1161X
-10 +70°C
Uncertified
This model of the DLI is the uncertified version
used in weatherproof assemblies
N/A
-10 +70°C
Excellence the World can Measure
TM
DLI1 Dimensions
DLI1 Connection Diagram
TM
DLI - Ordering Code
Model DLI
DLI
Type
Enclosed
Non-Enclosed
Uncertified
E
N
U
Range
Enter Minimum Range (Negative starts with N)
XXXX
Enter maximum Range (Positive starts with P)
XXXX
Unit of Measure
Degree C (ºC)
Degree F (ºF)
C
F
Example Order Code
yy
yy
yy
yy
yy
DLI
E
DLI
Enclosed Unit
-100 Minimum Temperature
+200 Minimum Temperature
Deg C
N0100
P0100
C
TM
ISO9001:2008
British Rototherm Company Limited
Kenfig Industrial Estate, Margam, Port Talbot SA13 2PW United Kingdom
Excellence the World can Measure
TM
T: +44 (0) 1656 740 551 E: [email protected]
F: +44 (0) 1656 745 915
W: www.rotothermgroup.com
In keeping with British Rototherm’s policy for continual product development and improvement, we reserve the right to amend specifications without notice.
©2012 Rototherm Group. All rights reserved. Company registered in Wales : 2570730. Registered office as above.