Santa Fe - University of Missouri
Transcription
Santa Fe - University of Missouri
The Vaporization Enthalpies and Vapor Pressures of Two Insecticide Components, Muscalure and Empenthrin By Correlation Gas Chromatography Jessica Spencer and James Chickos Department of Chemistry and Biochemistry University of Missouri-St. Louis Louis MO 63121 E-mail: [email protected] A portion of the Science Complex at UMSL Outline of the Presentation Properties of the targets Introduction to the fundamentals of correlation gas chromatography Demonstration of the method as applied to: Muscalure Application to evaluate the vaporization enthalpy and vapor pressure of empenthrin Comparison of the results on empenthrin with those obtained by another gas chromatographic retention time method that has been criticized recently 1 1 Ruzicka, K.; Koutek, B.; Fulem, M.; Hoskovec, M. Indirect Determination of Vapor Pressures by Capillary Gas-Liquid Chromatography: Analysis of the Reference Vapor –Pressure Data and Their Treatment. J. Chem. Eng. Data 2011, 57, 1349-68. Information on the Compounds Investigated Muscalure: Z 9-Tricosene, is a sex pheromone produce by female house flies (Musca domestica). Muscalure in combination with other fecal odors provides maximum attraction for male flies. It is used as a pesticide is in combination with fly paper or other traps. Z 9-Tricosene also serves as a communication pheromone in the waggle dance of bees. The synthetic sample also contains a small amount of E 9-Tricosene. Empenthrin: (E)-(RS)-1-ethynyl-2-methylpent-2-enyl (1RS)-cis-trans-2,2-dimethyl-3-(2-methylprop-1-enyl)cyclopropane-carboxylate is a synthetic pyrethrin used as a pesticide. It has a broad spectrum of activity on various flying insects but relatively low mammalian toxicity. It consists of a racemic mixture of up to 4 possible diasteriomers. At least three of the diasteriomers were detected in the commercial product. 40000 5500 5000 30000 Intensity Intensity/arbitrary units 4500 FIGURE 1 Gas chromatograph. From left to right: hexane, nonadecane, eicosane, henicosane, docosane, Z-9-tricosene (muscalure), E-9-tricosene, tetracosene Z 4000 E 3500 3000 20000 2500 2000 12.0 10000 13.0 13.5 14.0 T/min 0 5 10 T/min 13C 12.5 NMR 15 20 40000 5500 5000 30000 4500 Intensity Intensity/arbitrary units FIGURE 2. Gas chromatograph. From Left to right: CH2Cl2, methyl dodecanoate, empenthrin 1 and 2, methyl tetradecanoate, methyl hexadecanoate, methyl octadecanoate, ethyl octadecanoate, methyl nonadecanoate on a 5% phenylmethyl silicone column. 4000 3500 3000 20000 2500 2000 4.2 4.4 4.6 4.8 5.0 5.2 T/min 10000 0 5 10 15 T/min 1H NMR 2.45 ppm 20 25 Fundamentals of Correlation Gas Chromatography- Vaporization Enthalpy 1. The residence time of a compound on the column, ta, is inversely proportional the compounds vapor pressure (ta = retention time of a solute – retention time of a non-retained reference , ta = t – tnrr (often the solvent) 2. A plot of ln(to/ta), where to is the reference time, 1 min, versus 1/T over a 30 K temperature range results in a straight line 3. The slope of the line, -∆Htrn(Tm)/R, is the enthalpy of transfer of the analyte from the column to the gas phase 4. The enthalpy of transfer is related to the vaporization enthalpy (∆lgH(T) by the following equation where ∆Hsln represents the enthalpy of interaction of the solute with the column: ∆Htrn(Tm) = ∆lgH (Tm) + ∆Hsln (Tm) 5. If a series of standards are properly selected, a second plot of ∆lgH(298.15 K) versus ∆Htrn(Tm) of the standards is also linear and the equation of the line can be used to evaluate the vaporization enthalpy of any additional targets included in the mixture 6. Appropriate standards with known vaporization enthalpies generally include compounds with the same number and type of functionality as the targets. The structure of the hydrocabon portion of the molecule may vary Fundamentals of Correlation Gas Chromatography - Vapor Pressure Use of appropriate standards with known vapor pressures also results in linear plots between ln(p/po) and ln(to/ta) The equation of the line plus values of ln(to/ta) of the targets results in their vapor pressures Performed over a range of temperatures can provide the vapor pressure temperature profile of the targets Vaporization Enthalpies and Vapor Pressure Equations of the Standards (po = 101325 Pa) ln (p/po) = (1-Tnb/T)exp(Ao +A1T + A2T2) Cox equation ln(p/po) = AT -3 + BT -2 + C T -1 + D Third order polynomial Rln(p/po) = - cdgG°()/ + lgH°()[1/ - 1/T] + cdgCp,m()[/T -1 + ln(T/)] Equation of Clark and Glew 2 TABLE 2.Experimental Retention Times of Muscalure and Various Alkanes -0.5 -1.0 FIGURE 3. A plot of ln(to/ta) where to = 1 min and ta is equal to the difference in retention time between each analyte and a non-retained reference (the solvent) against 1/T. ln(to/ta) -1.5 -2.0 -2.5 -3.0 -3.5 0.00192 0.00194 0.00196 0.00198 0.00200 0.00202 0.00204 0.00206 0.00208 1/(T/K) TABLE 3. Correlation of Enthalpies of Transfer With Vaporization Enthalpies: Muscalure lgHm(298.15 K)/kJmol-1 = (1.640.01)Htrn(500 K) - (3.460.7) r 2 = 0.9999 125 120 g -1 l H(298 K) / kJ.mol FIGURE 4. Vaporization enthalpy of muscalure and standards. From left to right: eicosane, heneicosane, docosane, Z 9-tricosene, E 9-tricosene, tetracosane. 115 110 105 100 62 64 66 68 70 72 Htrn(Tm)/ kJ.mole-1 74 76 78 TABLE 4. A Summary of the Vaporization Enthalpies of Muscalure 2 Values in italics are estimated using the following equation for hydrocarbons: ∆lgH(298.15 K) = 4.69(n-nQ) + 1.3 nQ +3.0 + b + C n = number of carbon atoms: 23 nQ = number of quaternary sp3 carbon atoms: 0 b = contribution of a functional group: 0 branching correction: 0 TABLE 5. Correlation Between ln(to/ta) and Literature ln(p/po) for Muscalure at T = 298.15 K ln(p/po) = (1.37 0.003) ln(to/ta) - (1.608 0.044) r 2 = 0.9999 -17 p/Pa(298,15) = 1.2·10-4 (Z) -18 p/Pa(298,15) = 1.1·10-4 (E) FIGURE 5. A plot of ln(p/po) vs ln(to/ta) where po = 101325 Pa for muscalure at T = 298.15 K. From left to right: tetracosane, Z-9tricosene, E 9-tricosene, docosane, heneicosane, and eicosane. ln(p/po) -19 -20 -21 -22 -23 -15.5 -15.0 -14.5 -14.0 -13.5 ln(to/ta) -13.0 -12.5 -12.0 -11.5 The correlation between ln(to/ta) and literature values of ln(p/po) for Muscalure and the standards was repeated from T = (298.15 to 500) K at 10 K intervals resulting in the following (r 2 for all correlations >0.99): ln(p/po) = AT -3 + BT -2 + C T -1 + D Third order polynomial TABLE 7. A Summary of Liquid/Subcooled Liquid Vapor Pressures and Normal Boiling Temperatures and Comparison with Experimental or Estimated Values (in italics) a Estimation from US EPA; Estimation Program Interface EPI Suite Version 4.11 b SciFinder Scholar: Estimated using Advanced Chemistry Development (ACD/Labs) Software V11.02 c Khanal, O.; Schooter, D. Chemical analysis of organics in atmospheric particulates by headspace analysis. Atmos. Environ. 2004, 38(40), 6917-6925. d Boiling temperature at p = 133 Pa. Yadav, J. S.; Ready, P. S.; Joshi, B.V. A convenient reduction of alkylated tosylmethyl isocyanides. Applications for the synthesis of natural products. Tetrahedron 1988, 44, 7243-54. Evaluation of Empenthrin The vapor pressure of numerous substances have been measured by the gas chromatography - retention time method 1 which differs from the method just discussed. Vapor pressure: Gas Chromatography - Retention Time Method The vapor pressure - retention time method consists in ploting ln[(tr)tar/(tr)ref ]T against ln(pref,,T) at different temperatures resulting in the following linear relationship: ln[(tr)tar/(tr)ref ]T = [1- (lgH)tar/(lgH)ref] ln(p ref, T) - C (tr)tar and lgH)tar are the relative retention time and vaporization enthalpy of the target (tr)ref and lgH)ref refer to the corresponding properties of the reference materials. The slope and intercept of the line obtained is given by [1- (lgH)tar/(lgH)ref] and - C The vapor pressure of the target at T = 298.15 K is obtained from: ln(ptar, 298.15 K/Pa) = [(lgH)tar/(lgH)ref] ln(p ref, 298.15 K/Pa) + C 1 Hamilton, D. J. Gas Chromatographic Measurement of Volatility of Herbicide Esters. J. Chromatography 1980, 195, 75-83. Tsuzuki1 using an modification of the gas chromatographic method just described, used dibutyl phthalate and bis 2-ethylhexyl phthalate as standards and measured a number of other esters including empenthrin and the following: CO2CH2CHCH2(CH)2CH3 CO2CH2(CH2)2CH3 CH2CH3 CH2CH3 CO2CH2CH(CH2(CH2)CH CO2CH2(CH2)2CH3 N CF3 Cl O O Cl O O O CF3 fluvalinate permethrin O Cl O Cl O CF3 N fenvalerate O bifenthrin It is not clear well phthalate diesters can serve as standards to these pyrethrinoids which in addition to being single esters have a variety of other functional groups.. 1 Tsuzuki, M. Vapor pressures of carboxylic esters including pyrethroids: measurement and estimation from molecular structure. Chemosphere 2001, 45, 729-36. FIGURE 6. Vaporization enthalpy at T = 298.15 K versus the enthalpy of transfer of fatty acid methyl esters (FAMES) and dialkyl phthalates evaluated simultaneously TABLE 8. ∆trnH(Tm) versus ∆lgH(298.15 K) FAMES Diesters Evaluation of the Vapor Pressure and Vaporization Enthalpy of Empenthrin Using FAMES O CH3(CH2)nCH 2 C OCH3 n = 9, 12, 13, 15, 16 TABLE 9. Experimental Retention Times of Empenthrin with Various Esters 0.5 0.0 -0.5 -1.0 ln(to/ta) FIGURE 7. A plot of ln(to/ta) where to = 60 s and ta is equal to the difference in retention time between each analyte and a nonretained reference (the solvent) against 1/T. -1.5 -2.0 -2.5 -3.0 -3.5 0.00200 0.00202 0.00204 0.00206 0.00208 0.00210 0.00212 0.00214 0.00216 0.00218 1/(T/K) TABLE 10. Correlation of Enthalpies of Transfer With Vaporization Enthalpies: Empenthrin lgHm(298.15 K)/kJmol-1 = (1.480.055)Htrn(480 K) - (2.593.6), r2 = 0.9944 120 FIGURE 8. Vaporization enthalpy of empenthrin and standards. From left to right: methyl dodecanoate, empenthrin I, empenthrin 2, methyl hexadecanoate, methyl octadecanoate, ethyl octadecanoate methyl nonadecanoate. g -1 l H (298.15) / kJ.mol 110 100 90 80 70 45 50 55 60 Htrn(Tm) / kJ.mol-1 65 70 75 TABLE 11. A Comparison of Vaporization Enthalpies at T/K = 298.15 of Empenthrin and Standards With Literature and Estimated Values (in italics) aValues in italics are estimated using the following equation for hydrocarbons: ∆lgH(298.15 K) = 4.69(n-nQ) + 1.3 nQ +3.0 + b + C n = number of carbon atoms: 18 nQ = number of quaternary sp3 carbon atoms: 1 b = contribution of a functional group: 10.5 branching correction: -2 TABLE 12. Correlation Between ln(to/ta) and Literature ln(p/po) for Empenthrin at T =298.15 K ln(p/po) = (1.25 0.032) ln(to/ta) avg - (2.24 0.38 ) r 2 = 0.9979 -10 -12 -14 ln(p/po) FIGURE 9. A plot of ln(p/po) vs ln(to/ta) where po = 101325 Pa at T = 298.15 K for empenthrin. From left to right: methyl nonadecanoate, ethyl octadecanoate, methyl octadecanoate, methyl hexadecanoate, methyl pentadecanoate, empenthrin 2, empenthrin 1, methyl dodecanoate. -16 -18 -20 -22 -15 -14 -13 -12 -11 ln(to/ta) -10 -9 -8 -7 Repeating this process at 10 K intervals from T = (298.15 to 480) K resulted in the following vapor pressure – temperature profile; the data were fit to the following equation: ln(p/po) = AT -3 + BT -2 + C T -1 + D. All r 2 > 0.99. TABLE 13. A Summary of Liquid/Subcooled Liquid Vapor Pressures and Normal Boiling Temperatures and Comparison with Experimental Values 1Tsuzuki, M. Vapor pressures of carboxylic esters including pyrethroids: measurement and estimation from molecular structure. Chemosphere 2001, 45, 729-36. 2 SciFinder Scholar; obtained from Syracuse Research Corporation of Syracuse, New York. 3 SciFinder Scholar, estimate. TABLE 14. Application of the Gas Chromatographic – Retention Time Method Using Fatty Acid Methyl Esters as Standards lgHm(298.15 K)/(kJ·mol-1) = lgHm(Tm) + [(10.58 + 0.26·Cp(l)/(J·mol-1·K-1))( Tm/K 298.15 K)]/1000 Acknowledgements: Jessica Spencer and FKS Inc for financial support Vaporization Enthalpies and Vapor Pressures of Two Insecticide Components, Muscalure and Empenthrin, by Correlation Gas Chromatography. Spencer, J.; Chickos, J. Chem. Eng. Data 2013, 59, 3513-20. Ruzicka, K.; Koutek, B.; Fulem, M.; Hoskovec, M. Indirect Determination of Vapor Pressures by Capillary Gas- Liquid Chromatography: Analysis of the Reference Vapor –Pressure Data and Their Treatment. J. Chem. Eng. Data 2011, 57, 1349-68.