SR18
PRODUCT FEATURES
TYPICAL APPLICATIONS
�
�
�
�
�
�
�
�
�
�
�
�
�
Maintenance free
Oil-less
Compact
Pulsation free
High flow
Low vibration
No valves
Reversible
Automotive
Medical
Analysis
Automation
Fuell Cell
Rotary Vane Vacuum and Pressure Pumps
Product Overview
Model
Flow
Max. Pressure
Max. vaccum
Page
G 01-K-LC
2,2 l/min
80 mbar
7%
3
G 01-K-EB
1,4 l/min
40 mbar
4%
4
G 01 EB
1,6 l/min
180 mbar
20 %
5
G 01-4 EB
1,4 l/min
280 mbar
29 %
6
G 02 EB
3,6 l/min
190 mbar
19 %
7
3,7 l/min
310 mbar
31 %
G 02-8
2,7 l/min
410 mbar
37 %
9
BL-G 02-4
2,1 l/min
200 mbar
19 %
10
G 04 EB
6,8 l/min
150 mbar
16 %
11
5,1 l/min
240 mbar
26 %
G 04-8
4,4 l/min
260 mbar
25 %
13
G 045-LC
6,5 l/min
750 mbar
63 %
14
G 045
6,1 l/min
750 mbar
70 %
15
G 07
21 l/min
1400 mbar
77 %
16
G 07-N
20 l/min
900 mbar
72 %
17
G 08
15,5 l/min
1400 mbar
83 %
18
G 08-T
36 l/min
1400 mbar
93 %
19
BL-G 085 M
8,5 l/min
450 mbar
50 %
20
G 09
11 l/min
370 mbar
35 %
21
G 02-4 EB
G 04-4 EB
2
8
12
Rotary Vane Pump G 01-K-LC
2,2 l/min
80 mbar
7%
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 6/01-K-LCL
50027
2,0 l/min
60 mbar
25 mbar
6 %
2,5 %
G 6/01-K-LC
50017
2,2 l/min
80 mbar
25 mbar
7 %
2,5 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Permanent magnet
6 V DC
0,17 A
0,23 A
IP40
Sleeve bearing
Permanent magnet
6 V DC
0,18 A
0,27 A
IP40
Sleeve bearing
General Data
Ambient temperature
Weight
Direction of rotation
0 to 40 °C
0,03 kg
cw/ccw
0 to 40 °C
0,03 kg
cw/ccw
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Flow [l/min]
2,4
Continuous operation
Intermittent operation
2,2
2,0
500...
G 6/01-K-LC
G 6/01-K-LCL
G 6 / 01 - K - LCL
1,8
DC
1,6
Plastic
housing
Model
type
1,4
1,2
Improved
condensation
tolerance
1,0
0,8
0,6
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
0,4
0,2
0
8
6
Vacuum rel. [%]
4
2
0
20
40
60
80
Pressure [mbar]
3
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Nominal
voltage
Rotary Vane Pump G 01-K-EB
1,4 l/min
40 mbar
4%
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 6/01-K-EB12
50251
0,9 l/min
20 mbar
10 mbar
2%
1%
G 6/01-K-EB9L
50094
1,2 l/min
25 mbar
10 mbar
2,8 %
1%
G 6/01-K-EB9
50250
1,4 l/min
40 mbar
10 mbar
4%
1%
G 12/01-K-EB18L
50080
1,2 l/min
18 mbar
10 mbar
1,8 %
1%
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Ironless Core DC
6 V DC
18 mA
30 mA
IP50
Sleeve bearing
Ironless Core DC
6 V DC
36 mA
65 mA
IP50
Sleeve bearing
Ironless Core DC
6 V DC
50 mA
70 mA
IP50
Sleeve bearing
Ironless Core DC
12 V DC
25 mA
48 mA
IP50
Sleeve bearing
General Data
Ambient temperature
Weight
Direction of rotation
-20 to 40° C
0,04 kg
cw/ccw
-20 to 40° C
0,04 kg
cw/ccw
-20 to 40° C
0,04 kg
cw/ccw
-20 to 40° C
0,04 kg
cw/ccw
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
1,6
Flow [l/min]
Continuous operation
Intermittent operation
1,4
Nominal
voltage
G 6/01-K-EB9
G 6/01-K-EB9L
G 12/01-K-EB18L
G 6/01-K-EB12
1,2
50...
Ironless
motor
Nominal
motor voltage
G 6 / 01 - K - EB9L
DC
1,0
Plastic
housing
Model
type
0,8
0,6
Improved
condensation
tolerance
0,4
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
0,2
0
4
3
Vacuum rel. [%]
2
1
0
10
20
30
40
Pressure [mbar]
4
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 01 EB
1,6 l/min
180 mbar
20 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 3/01 EB
50083
0,9 l/min
90 mbar
80 mbar
9%
8%
G 6/01 EB
50081
1,0 l/min
120 mbar
80 mbar
12 %
8%
G 12/01 EB
50096
1,4 l/min
150 mbar
100 mbar
16 %
10 %
G 24/01 EB
50099
1,6 l/min
180 mbar
100 mbar
20 %
10 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Ironless Core DC
3 V DC
0,12 A
0,28 A
IP50
Sleeve bearing
Ironless Core DC
6 V DC
0,07 A
0,19 A
IP50
Sleeve bearing
Ironless Core DC
12 V DC
0,09 A
0,20 A
IP50
Sleeve bearing
Ironless Core DC
24 V DC
0,05 A
0,13 A
IP50
Sleeve bearing
General Data
Ambient temperature
Weight
Direction of rotation
-30 to 50 °C
0,1 kg
cw
-30 to 50 °C
0,1 kg
cw
-30 to 50 °C
0,1 kg
cw
-30 to 50 °C
0,1 kg
cw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Flow [l/min]
1,8
Continuous operation
Intermittent operation
1,6
500...
Nominal
voltage
G 24/01 EB
G 12/01 EB
G 6/01 EB
G 3/01 EB
1,4
G 6 / 01 EB
DC
1,2
Ironless
motor
Model
type
1,0
0,8
0,6
0,4
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
0,2
0
20
15
Vacuum rel. [%]
10
5
0
50
100
150
200
Pressure [mbar]
5
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 01-4-EB
1,4 l/min
280 mbar
29 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 6/01-4 EB
50088
1,0 l/min
180 mbar
100 mbar
20 %
10 %
G 12/01-4 EB
50090
1,4 l/min
280 mbar
100 mbar
28 %
10 %
G 24/01-4 EB
50092
1,4 l/min
280 mbar
100 mbar
29 %
10 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Ironless Core DC
6 V DC
0,10 A
0,32 A
IP50
Sleeve bearing
Ironless Core DC
12 V DC
0,11 A
0,31 A
IP50
Sleeve bearing
Ironless Core DC
24 V DC
0,06 A
0,17 A
IP50
Sleeve bearing
General Data
Ambient temperature
Weight
Direction of rotation
-30 to 50 °C
0,1 kg
cw/ccw
-30 to 50 °C
0,1 kg
cw/ccw
-30 to 50 °C
0,1 kg
cw/ccw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Flow [l/min]
1,6
Continuous operation
Intermittent operation
1,4
500...
Nominal
voltage
G 24/01-4 EB
G 12/01-4 EB
G 6/01-4 EB
Number of
vanes
G 6 / 01 - 4 EB
1,2
DC
1,0
Ironless
motor
Model
type
0,8
0,6
0,4
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
0,2
0
40
30
Vacuum rel. [%]
20
10
0
100
200
300
400
Pressure [mbar]
6
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 02 EB
3,6 l/min
190 mbar
19 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 3/02 EB
50084
2,4 l/min
110 mbar
90 mbar
11 %
9%
G 6/02 EB
50103
2,6 l/min
120 mbar
80 mbar
12 %
8%
G 12/02 EB
50095
3,6 l/min
180 mbar
100 mbar
18 %
10 %
G 24/02 EB
50098
3,6 l/min
190 mbar
100 mbar
19 %
10 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Ironless Core DC
3 V DC
0,16 A
0,53 A
IP50
Sleeve bearing
Ironless Core DC
6 V DC
0,09 A
0,30 A
IP50
Sleeve bearing
Ironless Core DC
12 V DC
0,09 A
0,33 A
IP50
Sleeve bearing
Ironless Core DC
24 V DC
0,07 A
0,18 A
IP50
Sleeve bearing
General Data
Ambient temperature
Weight
Direction of rotation
-30 to 50 °C
0,1 kg
cw
-30 to 50 °C
0,1 kg
cw
-30 to 50 °C
0,1 kg
cw
-30 to 50 °C
0,1 kg
cw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Flow [l/min]
4,0
Continuous operation
Intermittent operation
3,6
50...
Nominal
voltage
G 24/02 EB
G 12/02 EB
G 6/02 EB
G 3/02 EB
3,2
G 6 / 02 EB
DC
2,8
Ironless
motor
Model
type
2,4
2,0
1,6
1,2
0,8
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
0,4
0
20
15
Vacuum rel. [%]
10
5
0
50
100
150
200
Pressure [mbar]
7
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 02-4 EB
3,7 l/min
310 mbar
31 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 6/02-4 EB
50089
2,6 l/min
230 mbar
100 mbar
23 %
10 %
G 12/02-4 EB
50091
3,5 l/min
310 mbar
100 mbar
31 %
10 %
G 24/02-4 EB
50093
3,7 l/min
310 mbar
100 mbar
31 %
10 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Ironless Core DC
6 V DC
0,13 A
0,53 A
IP50
Sleeve bearing
Ironless Core DC
12 V DC
0,15 A
0,51 A
IP50
Sleeve bearing
Ironless Core DC
24 V DC
0,09 A
0,27 A
IP50
Sleeve bearing
General Data
Ambient temperature
Weight
Direction of rotation
-30 to 50 °C
0,1 kg
cw/ccw
-30 to 50 °C
0,1 kg
cw/ccw
-30 to 50 °C
0,1 kg
cw/ccw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Flow [l/min]
4,0
G 24/02-4 EB
G 12/02-4 EB
G 6/02-4 EB
Continuous operation
Intermittent operation
3,6
500...
Nominal
voltage
3,2
Number of
vanes
G 6 / 02 - 4 EB
DC
2,8
Ironless
motor
Model
type
2,4
2,0
1,6
1,2
0,8
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
0,4
0
40
30
Vacuum rel. [%]
20
10
0
100
200
300
400
Pressure [mbar]
8
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 02-8
2,7 l/min
410 mbar
37 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 6/02-8
50163
2,6 l/min
410 mbar
200 mbar
37 %
20 %
G 12/02-8
50165
2,7 l/min
410 mbar
200 mbar
37 %
20 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Ironless Core DC
6 V DC
0,23 A
0,70 A
IP50
Ball bearing
Ironless Core DC
12 V DC
0,11 A
0,35 A
IP50
Ball bearing
General Data
Ambient temperature
Weight
Direction of rotation
-30 to 50 °C
0,13 kg
cw/ccw
-30 to 50 °C
0,13 kg
cw/ccw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
3,0
Nominal
voltage
Flow [l/min]
Continuous operation
Intermittent operation
2,7
G 12/02-8
G 6/02-8
2,4
501...
Number of
vanes
G 6 / 02 - 8
DC
2,1
1,8
Model
type
1,5
1,2
0,9
0,6
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
0,3
0
50
37,5
Vacuum rel. [%]
25
12,5
0
125
250
375
500
Pressure [mbar]
9
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump BL-G 02-4
2,4 l/min
200 mbar
22 %
Dimensions in mm [inch]
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
BL-G 12/02-4
50180
2,1 l/min
200 mbar
150 mbar
19 %
15 %
Electrical Data
Motor type
Nominal voltage
Drive electronics
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Connector
Housing:
Terminal:
Wiring diagram
Brushless DC
12 V DC
integrated with reverse supply voltage protection
0,16 A
0,33 A
IP00
Ball bearing
Molex KK 22-01-2045
Molex KK 08-50-0031
Optional:Adapter for 2-wire duty incl.
potentiometer for speed
adjustment
part number 29011932
General Data
Ambient temperature
Weight
Direction of rotation
Pin 1
Function
V Supply
Colour
Red
Pin 2
Pin 3
Ground
Speed control
Black
White
Pin 4
Tacho out
Green
Control
12 VDC
(max. voltage range: 10..18 VDC)
24 VDC
(max. voltage range: 10..28 VDC)
Ground for Vsupply (PIN 1) and Speed Control (PIN3)
analog: 0..5 VDC (max. 28V)
PWM: 6..20 kHz - 14..96%
Speed voltage input threshold: 0,2 V
18 pulses per revolution
Pulse time „LOW“: 195 µs
Output level „LOW“: 0 / max. 0,5 V
Output level „HIGH“: min. 4 V / max. 5 V
0 to 50 °C
0,13 kg
cw
Pumps include mounting bracket
Above performance values are based on max. control voltage 5V
All listed values are measured at standard atmospheric conditions and at 50Hz.
Flow Curves
Flow [l/min]
2,4
Model key:
BL-G12/02-4 5V
BL-G12/02-4 1V
2,2
501...
Nominal Number of
voltage
vanes
2,0
1,8
BL - G 12/02 - 4
1,6
Brushless Model
type
motor
DC
1,4
1,2
1,0
0,8
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
0,6
0,4
0,2
0
25 20 15 10
Vacuum rel. [%]
5
0
50 100 150 200 250
Pressure [mbar]
10
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 04 EB
6,8 l/min
150 mbar
16 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 3/04 EB
50085
4,5 l/min
100 mbar
50 mbar
11 %
5%
G 6/04 EB
50102
4,7 l/min
110 mbar
50 mbar
12 %
5%
G 12/04 EB
50097
6,2 l/min
140 mbar
50 mbar
15 %
5%
G 24/04 EB
50104
6,8 l/min
150 mbar
40 mbar
16 %
4%
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Ironless Core DC
3 V DC
0,26 A
0,80 A
IP50
Ball bearing/Sleeve bearing
Ironless Core DC
6 V DC
0,16 A
0,48 A
IP50
Ball bearing/Sleeve bearing
Ironless Core DC
12 V DC
0,18 A
0,47 A
IP50
Ball bearing/Sleeve bearing
Ironless Core DC
24 V DC
0,11 A
0,26 A
IP50
Ball bearing/Sleeve bearing
General Data
Ambient temperature
Weight
Direction of rotation
-30 to 50 °C
0,1 kg
cw
-30 to 50 °C
0,1 kg
cw
-30 to 50 °C
0,1 kg
cw
-30 to 50 °C
0,1 kg
cw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Flow [l/min]
8
Continuous operation
Intermittent operation
7
50...
Nominal
voltage
G 24/04 EB
G 12/04 EB
G 6/04 EB
G 3/04 EB
6
G 6 / 04 EB
DC
5
Ironless
motor
Model
type
4
3
2
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
1
0
20
15
Vacuum rel. [%]
10
5
0
50
100
150
200
Pressure [mbar]
11
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 04-4-EB
5,1 l/min
240 mbar
26 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 6/04-4 EB
50101
4,0 l/min
200 mbar
50 mbar
21 %
5%
G 12/04-4 EB
50100
5,1 l/min
240 mbar
50 mbar
26 %
5%
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Ironless Core DC
6 V DC
0,30 A
0,85 A
IP50
Ball bearing/Sleeve bearing
Ironless Core DC
12 V DC
0,29 A
0,70 A
IP50
Ball bearing/Sleeve bearing
General Data
Ambient temperature
Weight
Direction of rotation
-30 to 50 °C
0,1 kg
cw/ccw
-30 to 50 °C
0,1 kg
cw/ccw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Flow [l/min]
5,5
G 12/04-4 EB
G 6/04-4 EB
Continuous operation
Intermittent operation
5,0
4,5
50...
Nominal
voltage
Number of
vanes
G 6 / 04 - 4 EB
DC
4,0
3,5
Ironless
motor
Model
type
3,0
2,5
2,0
1,5
1,0
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
0,5
0
30
22,5
Vacuum rel. [%]
15
7,5
0
75
150
225
300
Pressure [mbar]
12
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 04-8
4,4 l/min
260 mbar
25 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 12/04-8
50119
4,4 l/min
260 mbar
100 mbar
25 %
10 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Ironless Core DC
12 V DC
0,21 A
0,51 A
IP50
Ball bearing
General Data
Ambient temperature
Weight
Direction of rotation
-30 to 50 °C
0,14 kg
cw/ccw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Nominal
voltage
Flow [l/min]
5,0
Continuous operation
Intermittent operation
4,5
G 12/04-8
Number of
vanes
G 12 / 04 - 8
4,0
DC
3,5
Model
type
3,0
2,5
2,0
1,5
1,0
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
0,5
0
30
22,5
Vacuum rel. [%]
15
7,5
0
75
150
225
300
Pressure [mbar]
13
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 045-LC
7,5 l/min
900 mbar
63 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 12/045-LC
50213
6,5 l/min
750 mbar
100 mbar
63 %
10 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Permanent magnet
12 V DC
1,8 A
3,5 A
IP20
Ball bearing / Sleeve bearing
General Data
Ambient temperature
Weight
Direction of rotation
-10 to 40 °C
0,25 kg
cw/ccw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
8
Nominal
voltage
Flow [l/min]
G 12/045-LC
Continuous operation
Intermittent operation
7
G 12 / 045 - LC
6
DC
5
Model
type
4
3
2
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
1
0
100
75
Vacuum rel. [%]
50
25
0
250
500
750
1000
Pressure [mbar]
14
502...
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 045
6,1 l/min
750 mbar
70 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 12/045
50200
5,5 l/min
650 mbar
150 mbar
58 %
15 %
G 24/045
50201
6,1 l/min
750 mbar
150 mbar
70 %
15 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Permanent magnet
12 V DC
0,64 A
1,36 A
IP30
Ball bearing
Permanent magnet
24 V DC
0,33 A
0,77 A
IP30
Ball bearing
General Data
Ambient temperature
Weight
Direction of rotation
10 to 40 °C
0,25 kg
cw/ccw
10 to 40 °C
0,25 kg
cw/ccw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Nominal
voltage
Flow [l/min]
6,5
6,0
Continuous operation
Intermittent operation
5,5
G 24/045
G 12/045
G 12 / 045
5,0
DC
4,5
4,0
Model
type
3,5
3,0
2,5
2,0
1,5
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
1,0
0,5
0
80
60
Vacuum rel. [%]
40
20
0
200
400
600
800
Pressure [mbar]
15
50...
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 07
21 l/min
1,4 bar
77 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 12/07-15 Watt
50336
17,0 l/min
1,3 bar
0,3 bar
76 %
30 %
G 24/07-15 Watt
50218
17,5 l/min
1,0 bar
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Permanent magnet
12 V DC
1,9 A
3,2 A
IP40
Ball bearing
Permanent magnet
24 V DC
1,1 A
1,6 A
IP40
Ball bearing
Permanent magnet
24 V DC
1,9 A
2,5 A
IP40
Ball bearing
General Data
Ambient temperature
Weight
Direction of rotation
-10 to 40 °C
0,6 kg
cw
-10 to 40 °C
0,6 kg
cw
-10 to 40 °C
0,7 kg
cw
G 24/07-30 Watt
50221
21,0 l/min
1,4 bar
0,2 bar
77 %
20 %
75 %
Pumps include tube connector (2x) G 1/8 to tube I.D. 6 mm, mounting bracket and filter (2x).
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Nominal
voltage
Flow [l/min]
22
G 24/07-30 Watt
G 24/07-15 Watt
G 12/07-15 Watt
Continuous operation
Intermittent operation
20
18
50...
Nominal
motor power
G 12 / 07 - 30 Watt
DC
16
14
Model
type
12
10
8
6
4
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
2
0
80
60
Vacuum rel. [%]
40
20
0
0,4
0,8
1,2
1,6
Pressure [bar]
16
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 07-N
20 l/min
0,9 bar
72 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 12/07-N
50316
20 l/min
0,90 bar
0,25 bar
70 %
25 %
G 24/07-N
50311
18 l/min
0,80 bar
0,30 bar
72 %
30 %
G 24/07-N rev.
50220
17 l/min
0,7 bar
0,3 bar
55 %
30 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Permanent magnet
12 V DC
2,6 A
4,6 A
IP40
Ball bearing
Permanent magnet
24 V DC
0,8 A
1,6 A
IP40
Ball bearing
Permanent magnet
24 V DC
0,9 A
2,0 A
IP40
Ball bearing
General Data
Ambient temperature
Weight
Direction of rotation
-10 to 40 °C
0,5 kg
cw
-10 to 40 °C
0,5 kg
cw
-10 to 40 °C
0,5 kg
cw / ccw
Pumps include mounting bracket.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Flow [l/min]
24
Continuous operation
Intermittent operation
22
20
50...
Nominal
voltage
G 12/07-N
G 24/07-N
G 24/07-N rev.
G 12 / 07 - N rev
DC
18
16
Reversible
Resin bonded
graphite housing
Model
type
14
12
10
8
6
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
4
2
0
80
60
Vacuum rel. [%]
40
20
0
0,3
0,6
0,9
1,2
Pressure [bar]
17
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 08
15,5 l/min
1,4 bar
83 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 12/08-30 Watt
50325
15,5 l/min
1,2 bar
0,3 bar
80 %
30 %
G 24/08-30 Watt
50358
15,5 l/min
1,4 bar
0,3 bar
83 %
30 %
G 24/08-30 Watt rev.
50360
15,5 l/min
1,2 bar
0,3 bar
74 %
30 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Permanent magnet
12 V DC
1,5 A
3,2 A
IP40
Ball bearing
Permanent magnet
24 V DC
0,8 A
1,6 A
IP40
Ball bearing
Permanent magnet
24 V DC
0,6 A
1,8 A
IP40
Ball bearing
General Data
Ambient temperature
Weight
Direction of rotation
-10 to 40 °C
0,75 kg
cw
-10 to 40 °C
0,75 kg
cw
-10 to 40 °C
0,75 kg
cw/ccw
Pumps include mounting bracket and filter.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Nominal
voltage
Flow [l/min]
16
Continuous operation
Intermittent operation
14
G 24 / 08 - 30 Watt rev.
G 12/08-30 Watt
G 24/08-30 Watt
G 24/08-30 Watt rev.
12
10
503...
Nominal motor
power
DC
Reversible
Model
type
8
6
4
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
2
0
100
80
Vacuum rel. [%]
60
40
20
0
0,5
1,0
1,5
Pressure [bar]
18
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Rotary Vane Pump G 08-T
36 l/min
1,4 bar
93 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
G 12/08-T
50241
connected in series
17 l/min
G 24/08-T
50238
connected in series
19 l/min
93 %
G 12/08-T
50241
connected in parallel
33 l/min
1,4 bar
84 %
93 %
G 24/08-T
50238
connected in parallel
36 l/min
1,4 bar
84 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Permanent magnet
12 V DC
4,0 A
5,0 A
IP40
Ball bearing
Permanent magnet
12 V DC
4,0 A
8,0 A
IP40
Ball bearing
Permanent magnet
24 V DC
2,0 A
2,5 A
IP40
Ball bearing
Permanent magnet
24 V DC
2,0 A
4,0 A
IP40
Ball bearing
General Data
Ambient temperature
Weight
Direction of rotation
-10 to 40 °C
1,3 kg
cw
-10 to 40 °C
1,3 kg
cw
-10 to 40 °C
1,3 kg
cw
-10 to 40 °C
1,3 kg
cw
Max. flow
Max. intermittent pressure
Max. intermittent vacuum
Pumps include mounting bracket (2x) and filter (2x).
These pumps are not suitable for continuous operation.
All listed values are measured at standard atmospheric conditions.
Model key:
Flow Curves
Flow [l/min]
39
36
Intermittent operation
33
G 12 / 08 - T
G 24/08-T 50238 Ps.
G 12/08-T 50241 Ps.
G 24/08-T 50238 Rs.
G 12/08-T 50241 Rs.
30
27
24
50...
DC
Double headed
Model
type
21
18
15
12
9
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
6
3
0
100
80
Vacuum rel. [%]
60
40
20
0
0,5
1,0
1,5
Pressure [bar]
19
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Nominal
voltage
Rotary Vane Pump BL-G 085 M
8,5 l/min
450 mbar
50 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
BL-G 12/085 M
50209
8,5 l/min
450 mbar
150 mbar
50 %
15 %
Electrical Data
Motor type*
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Electrical connection
Brushless DC
12 V DC
0,7 A
2,0 A
IP00
Ball bearing
Flex-Print connector, 11 poles, pitch 1,0 mm, top contact style
General Data
Ambient temperature
Weight
Direction of rotation
-40 to 60 °C
0,15 kg
cw/ccw
* without electronics
All listed values are measured at standard atmospheric conditions.
Please contact Thomas if further information regarding electrical connection and electronics is required.
Use provided mounting locations only. Do not allow force on either motor or pump head. Motor bearing can be damaged.
Model key:
Flow Curves
Nominal
voltage
Flow [l/min]
9
Continuous operation
Intermittent operation
8
BL-G 12/085 M
BL - G 12/085 M
7
Brushless
motor
6
Model
type
DC
5
50210
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
4
3
2
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
1
0
50
40
Vacuum rel. [%]
30
20
10
0
100
200
300
400
500
Pressure [mbar]
20
Pin allocation:
Pin 1 4,5 - 18 VDC
Pin 2 Hall sensor 3
Pin 3 Hall sensor 1
Pin 4 Hall sensor 2
Pin 5 GND
Pin 6 Motor winding 3
Pin 7 Motor winding 2
Pin 8 Motor winding 1
Option:
Adaptor for Flex-Print connector
to terminal board,
part number 63003
BL-G 12/085 M 50210 including
external electronics (63002)
+ adaptor (63003) for Flex-Print
connector
Rotary Vane Pump G 09
11 l/min
370 mbar
35 %
Dimensions in mm (inch)
Flow
Max. pressure
Max. vacuum
Pneumatic Data
Description
Part number
Max. flow
Max. intermittent pressure
Max. continuous pressure
Max. intermittent vacuum
Max. continuous vacuum
G 12/09-6 B
50330 / 50544
11,0 l/min
370 mbar
200 mbar
32 %
20 %
G 12/09-6 LC
50555 / 505521)
9,0 l/min
350 mbar
150 mbar
35 %
15 %
G 24/09-6 LC
50554 / 505561)
9,0 l/min
350 mbar
150 mbar
35 %
15 %
Electrical Data
Motor type
Nominal voltage
Min. current consumption
Max. current consumption
Protection class
Motor bearing
Permanent magnet
12 V DC
0,7 A
1,8 A
IP30
Ball bearing
Permanent magnet
12 V DC
0,7 A
2,2 A
IP20
Ball bearing / Sleeve bearing
Permanent magnet
24 V DC
0,4 A
1,3 A
IP20
Ball bearing / Sleeve bearing
General Data
Ambient temperature
Weight
Direction of rotation
-20 to 50 °C
0,24 kg
cw / ccw
-20 to 50 °C
0,30 kg
cw / ccw
-20 to 50 °C
0,30 kg
cw / ccw
Mounting bracket (Option) 31911 / 319141) 31947 / 319141)
All listed values are measured at standard atmospheric conditions.
1)
Pump including EPDM-cover for sound reduction.
For vacuum operation: change electrical polarity.
For noise reduction: do not remove green cap. To optimise flow: remove green cap.
Mounting on motor body only. Do not allow force on pump head.
Model key:
Flow Curves
Flow [l/min]
12
G 12/09-6 B
G 12/09-6 LC /
G 24/09-6 LC
Continuous operation
Intermittent operation
11
10
50...
Nominal
voltage
Number of
vanes
G 12 / 09 - 6 LC
9
DC
8
LC = Low-cost motor
B = Standard motor
Model
type
7
6
5
4
3
The information presented in this material is based on technical data and
test results of nominal units. It is believed to be accurate and reliable and is
offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended
use and the user assumes all risk and liability whatsoever in connection
therewith. Thomas does not warrant, guarantee or assume any obligation or
liability in connection with this information.
2
1
0
40
30
Vacuum rel. [%]
20
10
0
100
200
300
400
Pressure [mbar]
21
Stock programme
Current consumption:
Min.: at open flow
Max.: at max. intermittent operation
Wiring diagram (Brushless DC motor)
Pin 1
Function
V Supply
Colour
Red
Pin 2
Pin 3
Ground
Speed control
Black
White
Pin 4
Tacho out
Green
Control
12 VDC (max. voltage range: 10..18 VDC)
24 VDC (max. voltage range: 10..28 VDC)
Ground for Vsupply (PIN 1) and Speed Control (PIN3)
analog: 0..5 VDC (max. 28V)
PWM: 6..20 kHz - 14..96%
Speed voltage input threshold: 0,2 V
18 pulses per revolution
Pulse time „LOW“: 195 µs
Output level „LOW“: 0 / max. 0,5 V
Output level „HIGH“: min. 4 V / max. 5 V
Speed Input
Speed Output
+6V
+6V
74HC...
3K9
FG
Vin
10K
68K
Optional: Adapter for 2-wire duty
incl. potentiometer for
speed adjustment
56K
56K
470p
100n
Speed Output signal
V
5
0
195µs
Options / Accessories
P/N 29011932
Adapter for BLDC motor
4-2 wire w/ manual speed control
12 V DC
“red”
P/N 29011933
Adapter for BLDC motor
4-2 wire w/ manual speed control
24 V DC
“black”
22
t
Notes
23
Gardner Denver Thomas GmbH
Printed in Germany.
Art.-Nr.: 17000115 01/2015
Livry-Gargan-Str. 10 · 82256 Fürstenfeldbruck · Germany
Phone: +49 8141 2280 0 · Fax: +49 8141 8892136
e-Mail: [email protected] · http://www.gd-thomas.com