Rotary Vane Pumps Miniature Series
Transcription
Rotary Vane Pumps Miniature Series
Rotary Vane Pumps Miniature Series SR18 PRODUCT FEATURES TYPICAL APPLICATIONS � � � � � � � � � � � � � Maintenance free Oil-less Compact Pulsation free High flow Low vibration No valves Reversible Automotive Medical Analysis Automation Fuell Cell Rotary Vane Vacuum and Pressure Pumps Product Overview Model Flow Max. Pressure Max. vaccum Page G 01-K-LC 2,2 l/min 80 mbar 7% 3 G 01-K-EB 1,4 l/min 40 mbar 4% 4 G 01 EB 1,6 l/min 180 mbar 20 % 5 G 01-4 EB 1,4 l/min 280 mbar 29 % 6 G 02 EB 3,6 l/min 190 mbar 19 % 7 3,7 l/min 310 mbar 31 % G 02-8 2,7 l/min 410 mbar 37 % 9 BL-G 02-4 2,1 l/min 200 mbar 19 % 10 G 04 EB 6,8 l/min 150 mbar 16 % 11 5,1 l/min 240 mbar 26 % G 04-8 4,4 l/min 260 mbar 25 % 13 G 045-LC 6,5 l/min 750 mbar 63 % 14 G 045 6,1 l/min 750 mbar 70 % 15 G 07 21 l/min 1400 mbar 77 % 16 G 07-N 20 l/min 900 mbar 72 % 17 G 08 15,5 l/min 1400 mbar 83 % 18 G 08-T 36 l/min 1400 mbar 93 % 19 BL-G 085 M 8,5 l/min 450 mbar 50 % 20 G 09 11 l/min 370 mbar 35 % 21 G 02-4 EB G 04-4 EB 2 8 12 Rotary Vane Pump G 01-K-LC 2,2 l/min 80 mbar 7% Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 6/01-K-LCL 50027 2,0 l/min 60 mbar 25 mbar 6 % 2,5 % G 6/01-K-LC 50017 2,2 l/min 80 mbar 25 mbar 7 % 2,5 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Permanent magnet 6 V DC 0,17 A 0,23 A IP40 Sleeve bearing Permanent magnet 6 V DC 0,18 A 0,27 A IP40 Sleeve bearing General Data Ambient temperature Weight Direction of rotation 0 to 40 °C 0,03 kg cw/ccw 0 to 40 °C 0,03 kg cw/ccw All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Flow [l/min] 2,4 Continuous operation Intermittent operation 2,2 2,0 500... G 6/01-K-LC G 6/01-K-LCL G 6 / 01 - K - LCL 1,8 DC 1,6 Plastic housing Model type 1,4 1,2 Improved condensation tolerance 1,0 0,8 0,6 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 0,4 0,2 0 8 6 Vacuum rel. [%] 4 2 0 20 40 60 80 Pressure [mbar] 3 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Nominal voltage Rotary Vane Pump G 01-K-EB 1,4 l/min 40 mbar 4% Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 6/01-K-EB12 50251 0,9 l/min 20 mbar 10 mbar 2% 1% G 6/01-K-EB9L 50094 1,2 l/min 25 mbar 10 mbar 2,8 % 1% G 6/01-K-EB9 50250 1,4 l/min 40 mbar 10 mbar 4% 1% G 12/01-K-EB18L 50080 1,2 l/min 18 mbar 10 mbar 1,8 % 1% Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Ironless Core DC 6 V DC 18 mA 30 mA IP50 Sleeve bearing Ironless Core DC 6 V DC 36 mA 65 mA IP50 Sleeve bearing Ironless Core DC 6 V DC 50 mA 70 mA IP50 Sleeve bearing Ironless Core DC 12 V DC 25 mA 48 mA IP50 Sleeve bearing General Data Ambient temperature Weight Direction of rotation -20 to 40° C 0,04 kg cw/ccw -20 to 40° C 0,04 kg cw/ccw -20 to 40° C 0,04 kg cw/ccw -20 to 40° C 0,04 kg cw/ccw All listed values are measured at standard atmospheric conditions. Model key: Flow Curves 1,6 Flow [l/min] Continuous operation Intermittent operation 1,4 Nominal voltage G 6/01-K-EB9 G 6/01-K-EB9L G 12/01-K-EB18L G 6/01-K-EB12 1,2 50... Ironless motor Nominal motor voltage G 6 / 01 - K - EB9L DC 1,0 Plastic housing Model type 0,8 0,6 Improved condensation tolerance 0,4 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 0,2 0 4 3 Vacuum rel. [%] 2 1 0 10 20 30 40 Pressure [mbar] 4 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 01 EB 1,6 l/min 180 mbar 20 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 3/01 EB 50083 0,9 l/min 90 mbar 80 mbar 9% 8% G 6/01 EB 50081 1,0 l/min 120 mbar 80 mbar 12 % 8% G 12/01 EB 50096 1,4 l/min 150 mbar 100 mbar 16 % 10 % G 24/01 EB 50099 1,6 l/min 180 mbar 100 mbar 20 % 10 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Ironless Core DC 3 V DC 0,12 A 0,28 A IP50 Sleeve bearing Ironless Core DC 6 V DC 0,07 A 0,19 A IP50 Sleeve bearing Ironless Core DC 12 V DC 0,09 A 0,20 A IP50 Sleeve bearing Ironless Core DC 24 V DC 0,05 A 0,13 A IP50 Sleeve bearing General Data Ambient temperature Weight Direction of rotation -30 to 50 °C 0,1 kg cw -30 to 50 °C 0,1 kg cw -30 to 50 °C 0,1 kg cw -30 to 50 °C 0,1 kg cw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Flow [l/min] 1,8 Continuous operation Intermittent operation 1,6 500... Nominal voltage G 24/01 EB G 12/01 EB G 6/01 EB G 3/01 EB 1,4 G 6 / 01 EB DC 1,2 Ironless motor Model type 1,0 0,8 0,6 0,4 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 0,2 0 20 15 Vacuum rel. [%] 10 5 0 50 100 150 200 Pressure [mbar] 5 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 01-4-EB 1,4 l/min 280 mbar 29 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 6/01-4 EB 50088 1,0 l/min 180 mbar 100 mbar 20 % 10 % G 12/01-4 EB 50090 1,4 l/min 280 mbar 100 mbar 28 % 10 % G 24/01-4 EB 50092 1,4 l/min 280 mbar 100 mbar 29 % 10 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Ironless Core DC 6 V DC 0,10 A 0,32 A IP50 Sleeve bearing Ironless Core DC 12 V DC 0,11 A 0,31 A IP50 Sleeve bearing Ironless Core DC 24 V DC 0,06 A 0,17 A IP50 Sleeve bearing General Data Ambient temperature Weight Direction of rotation -30 to 50 °C 0,1 kg cw/ccw -30 to 50 °C 0,1 kg cw/ccw -30 to 50 °C 0,1 kg cw/ccw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Flow [l/min] 1,6 Continuous operation Intermittent operation 1,4 500... Nominal voltage G 24/01-4 EB G 12/01-4 EB G 6/01-4 EB Number of vanes G 6 / 01 - 4 EB 1,2 DC 1,0 Ironless motor Model type 0,8 0,6 0,4 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 0,2 0 40 30 Vacuum rel. [%] 20 10 0 100 200 300 400 Pressure [mbar] 6 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 02 EB 3,6 l/min 190 mbar 19 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 3/02 EB 50084 2,4 l/min 110 mbar 90 mbar 11 % 9% G 6/02 EB 50103 2,6 l/min 120 mbar 80 mbar 12 % 8% G 12/02 EB 50095 3,6 l/min 180 mbar 100 mbar 18 % 10 % G 24/02 EB 50098 3,6 l/min 190 mbar 100 mbar 19 % 10 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Ironless Core DC 3 V DC 0,16 A 0,53 A IP50 Sleeve bearing Ironless Core DC 6 V DC 0,09 A 0,30 A IP50 Sleeve bearing Ironless Core DC 12 V DC 0,09 A 0,33 A IP50 Sleeve bearing Ironless Core DC 24 V DC 0,07 A 0,18 A IP50 Sleeve bearing General Data Ambient temperature Weight Direction of rotation -30 to 50 °C 0,1 kg cw -30 to 50 °C 0,1 kg cw -30 to 50 °C 0,1 kg cw -30 to 50 °C 0,1 kg cw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Flow [l/min] 4,0 Continuous operation Intermittent operation 3,6 50... Nominal voltage G 24/02 EB G 12/02 EB G 6/02 EB G 3/02 EB 3,2 G 6 / 02 EB DC 2,8 Ironless motor Model type 2,4 2,0 1,6 1,2 0,8 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 0,4 0 20 15 Vacuum rel. [%] 10 5 0 50 100 150 200 Pressure [mbar] 7 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 02-4 EB 3,7 l/min 310 mbar 31 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 6/02-4 EB 50089 2,6 l/min 230 mbar 100 mbar 23 % 10 % G 12/02-4 EB 50091 3,5 l/min 310 mbar 100 mbar 31 % 10 % G 24/02-4 EB 50093 3,7 l/min 310 mbar 100 mbar 31 % 10 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Ironless Core DC 6 V DC 0,13 A 0,53 A IP50 Sleeve bearing Ironless Core DC 12 V DC 0,15 A 0,51 A IP50 Sleeve bearing Ironless Core DC 24 V DC 0,09 A 0,27 A IP50 Sleeve bearing General Data Ambient temperature Weight Direction of rotation -30 to 50 °C 0,1 kg cw/ccw -30 to 50 °C 0,1 kg cw/ccw -30 to 50 °C 0,1 kg cw/ccw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Flow [l/min] 4,0 G 24/02-4 EB G 12/02-4 EB G 6/02-4 EB Continuous operation Intermittent operation 3,6 500... Nominal voltage 3,2 Number of vanes G 6 / 02 - 4 EB DC 2,8 Ironless motor Model type 2,4 2,0 1,6 1,2 0,8 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 0,4 0 40 30 Vacuum rel. [%] 20 10 0 100 200 300 400 Pressure [mbar] 8 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 02-8 2,7 l/min 410 mbar 37 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 6/02-8 50163 2,6 l/min 410 mbar 200 mbar 37 % 20 % G 12/02-8 50165 2,7 l/min 410 mbar 200 mbar 37 % 20 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Ironless Core DC 6 V DC 0,23 A 0,70 A IP50 Ball bearing Ironless Core DC 12 V DC 0,11 A 0,35 A IP50 Ball bearing General Data Ambient temperature Weight Direction of rotation -30 to 50 °C 0,13 kg cw/ccw -30 to 50 °C 0,13 kg cw/ccw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves 3,0 Nominal voltage Flow [l/min] Continuous operation Intermittent operation 2,7 G 12/02-8 G 6/02-8 2,4 501... Number of vanes G 6 / 02 - 8 DC 2,1 1,8 Model type 1,5 1,2 0,9 0,6 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 0,3 0 50 37,5 Vacuum rel. [%] 25 12,5 0 125 250 375 500 Pressure [mbar] 9 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump BL-G 02-4 2,4 l/min 200 mbar 22 % Dimensions in mm [inch] Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum BL-G 12/02-4 50180 2,1 l/min 200 mbar 150 mbar 19 % 15 % Electrical Data Motor type Nominal voltage Drive electronics Min. current consumption Max. current consumption Protection class Motor bearing Connector Housing: Terminal: Wiring diagram Brushless DC 12 V DC integrated with reverse supply voltage protection 0,16 A 0,33 A IP00 Ball bearing Molex KK 22-01-2045 Molex KK 08-50-0031 Optional:Adapter for 2-wire duty incl. potentiometer for speed adjustment part number 29011932 General Data Ambient temperature Weight Direction of rotation Pin 1 Function V Supply Colour Red Pin 2 Pin 3 Ground Speed control Black White Pin 4 Tacho out Green Control 12 VDC (max. voltage range: 10..18 VDC) 24 VDC (max. voltage range: 10..28 VDC) Ground for Vsupply (PIN 1) and Speed Control (PIN3) analog: 0..5 VDC (max. 28V) PWM: 6..20 kHz - 14..96% Speed voltage input threshold: 0,2 V 18 pulses per revolution Pulse time „LOW“: 195 µs Output level „LOW“: 0 / max. 0,5 V Output level „HIGH“: min. 4 V / max. 5 V 0 to 50 °C 0,13 kg cw Pumps include mounting bracket Above performance values are based on max. control voltage 5V All listed values are measured at standard atmospheric conditions and at 50Hz. Flow Curves Flow [l/min] 2,4 Model key: BL-G12/02-4 5V BL-G12/02-4 1V 2,2 501... Nominal Number of voltage vanes 2,0 1,8 BL - G 12/02 - 4 1,6 Brushless Model type motor DC 1,4 1,2 1,0 0,8 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 0,6 0,4 0,2 0 25 20 15 10 Vacuum rel. [%] 5 0 50 100 150 200 250 Pressure [mbar] 10 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 04 EB 6,8 l/min 150 mbar 16 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 3/04 EB 50085 4,5 l/min 100 mbar 50 mbar 11 % 5% G 6/04 EB 50102 4,7 l/min 110 mbar 50 mbar 12 % 5% G 12/04 EB 50097 6,2 l/min 140 mbar 50 mbar 15 % 5% G 24/04 EB 50104 6,8 l/min 150 mbar 40 mbar 16 % 4% Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Ironless Core DC 3 V DC 0,26 A 0,80 A IP50 Ball bearing/Sleeve bearing Ironless Core DC 6 V DC 0,16 A 0,48 A IP50 Ball bearing/Sleeve bearing Ironless Core DC 12 V DC 0,18 A 0,47 A IP50 Ball bearing/Sleeve bearing Ironless Core DC 24 V DC 0,11 A 0,26 A IP50 Ball bearing/Sleeve bearing General Data Ambient temperature Weight Direction of rotation -30 to 50 °C 0,1 kg cw -30 to 50 °C 0,1 kg cw -30 to 50 °C 0,1 kg cw -30 to 50 °C 0,1 kg cw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Flow [l/min] 8 Continuous operation Intermittent operation 7 50... Nominal voltage G 24/04 EB G 12/04 EB G 6/04 EB G 3/04 EB 6 G 6 / 04 EB DC 5 Ironless motor Model type 4 3 2 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 1 0 20 15 Vacuum rel. [%] 10 5 0 50 100 150 200 Pressure [mbar] 11 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 04-4-EB 5,1 l/min 240 mbar 26 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 6/04-4 EB 50101 4,0 l/min 200 mbar 50 mbar 21 % 5% G 12/04-4 EB 50100 5,1 l/min 240 mbar 50 mbar 26 % 5% Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Ironless Core DC 6 V DC 0,30 A 0,85 A IP50 Ball bearing/Sleeve bearing Ironless Core DC 12 V DC 0,29 A 0,70 A IP50 Ball bearing/Sleeve bearing General Data Ambient temperature Weight Direction of rotation -30 to 50 °C 0,1 kg cw/ccw -30 to 50 °C 0,1 kg cw/ccw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Flow [l/min] 5,5 G 12/04-4 EB G 6/04-4 EB Continuous operation Intermittent operation 5,0 4,5 50... Nominal voltage Number of vanes G 6 / 04 - 4 EB DC 4,0 3,5 Ironless motor Model type 3,0 2,5 2,0 1,5 1,0 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 0,5 0 30 22,5 Vacuum rel. [%] 15 7,5 0 75 150 225 300 Pressure [mbar] 12 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 04-8 4,4 l/min 260 mbar 25 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 12/04-8 50119 4,4 l/min 260 mbar 100 mbar 25 % 10 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Ironless Core DC 12 V DC 0,21 A 0,51 A IP50 Ball bearing General Data Ambient temperature Weight Direction of rotation -30 to 50 °C 0,14 kg cw/ccw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Nominal voltage Flow [l/min] 5,0 Continuous operation Intermittent operation 4,5 G 12/04-8 Number of vanes G 12 / 04 - 8 4,0 DC 3,5 Model type 3,0 2,5 2,0 1,5 1,0 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 0,5 0 30 22,5 Vacuum rel. [%] 15 7,5 0 75 150 225 300 Pressure [mbar] 13 Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 045-LC 7,5 l/min 900 mbar 63 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 12/045-LC 50213 6,5 l/min 750 mbar 100 mbar 63 % 10 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Permanent magnet 12 V DC 1,8 A 3,5 A IP20 Ball bearing / Sleeve bearing General Data Ambient temperature Weight Direction of rotation -10 to 40 °C 0,25 kg cw/ccw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves 8 Nominal voltage Flow [l/min] G 12/045-LC Continuous operation Intermittent operation 7 G 12 / 045 - LC 6 DC 5 Model type 4 3 2 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 1 0 100 75 Vacuum rel. [%] 50 25 0 250 500 750 1000 Pressure [mbar] 14 502... Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 045 6,1 l/min 750 mbar 70 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 12/045 50200 5,5 l/min 650 mbar 150 mbar 58 % 15 % G 24/045 50201 6,1 l/min 750 mbar 150 mbar 70 % 15 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Permanent magnet 12 V DC 0,64 A 1,36 A IP30 Ball bearing Permanent magnet 24 V DC 0,33 A 0,77 A IP30 Ball bearing General Data Ambient temperature Weight Direction of rotation 10 to 40 °C 0,25 kg cw/ccw 10 to 40 °C 0,25 kg cw/ccw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Nominal voltage Flow [l/min] 6,5 6,0 Continuous operation Intermittent operation 5,5 G 24/045 G 12/045 G 12 / 045 5,0 DC 4,5 4,0 Model type 3,5 3,0 2,5 2,0 1,5 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 1,0 0,5 0 80 60 Vacuum rel. [%] 40 20 0 200 400 600 800 Pressure [mbar] 15 50... Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 07 21 l/min 1,4 bar 77 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 12/07-15 Watt 50336 17,0 l/min 1,3 bar 0,3 bar 76 % 30 % G 24/07-15 Watt 50218 17,5 l/min 1,0 bar Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Permanent magnet 12 V DC 1,9 A 3,2 A IP40 Ball bearing Permanent magnet 24 V DC 1,1 A 1,6 A IP40 Ball bearing Permanent magnet 24 V DC 1,9 A 2,5 A IP40 Ball bearing General Data Ambient temperature Weight Direction of rotation -10 to 40 °C 0,6 kg cw -10 to 40 °C 0,6 kg cw -10 to 40 °C 0,7 kg cw G 24/07-30 Watt 50221 21,0 l/min 1,4 bar 0,2 bar 77 % 20 % 75 % Pumps include tube connector (2x) G 1/8 to tube I.D. 6 mm, mounting bracket and filter (2x). All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Nominal voltage Flow [l/min] 22 G 24/07-30 Watt G 24/07-15 Watt G 12/07-15 Watt Continuous operation Intermittent operation 20 18 50... Nominal motor power G 12 / 07 - 30 Watt DC 16 14 Model type 12 10 8 6 4 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 2 0 80 60 Vacuum rel. [%] 40 20 0 0,4 0,8 1,2 1,6 Pressure [bar] 16 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 07-N 20 l/min 0,9 bar 72 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 12/07-N 50316 20 l/min 0,90 bar 0,25 bar 70 % 25 % G 24/07-N 50311 18 l/min 0,80 bar 0,30 bar 72 % 30 % G 24/07-N rev. 50220 17 l/min 0,7 bar 0,3 bar 55 % 30 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Permanent magnet 12 V DC 2,6 A 4,6 A IP40 Ball bearing Permanent magnet 24 V DC 0,8 A 1,6 A IP40 Ball bearing Permanent magnet 24 V DC 0,9 A 2,0 A IP40 Ball bearing General Data Ambient temperature Weight Direction of rotation -10 to 40 °C 0,5 kg cw -10 to 40 °C 0,5 kg cw -10 to 40 °C 0,5 kg cw / ccw Pumps include mounting bracket. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Flow [l/min] 24 Continuous operation Intermittent operation 22 20 50... Nominal voltage G 12/07-N G 24/07-N G 24/07-N rev. G 12 / 07 - N rev DC 18 16 Reversible Resin bonded graphite housing Model type 14 12 10 8 6 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 4 2 0 80 60 Vacuum rel. [%] 40 20 0 0,3 0,6 0,9 1,2 Pressure [bar] 17 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 08 15,5 l/min 1,4 bar 83 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 12/08-30 Watt 50325 15,5 l/min 1,2 bar 0,3 bar 80 % 30 % G 24/08-30 Watt 50358 15,5 l/min 1,4 bar 0,3 bar 83 % 30 % G 24/08-30 Watt rev. 50360 15,5 l/min 1,2 bar 0,3 bar 74 % 30 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Permanent magnet 12 V DC 1,5 A 3,2 A IP40 Ball bearing Permanent magnet 24 V DC 0,8 A 1,6 A IP40 Ball bearing Permanent magnet 24 V DC 0,6 A 1,8 A IP40 Ball bearing General Data Ambient temperature Weight Direction of rotation -10 to 40 °C 0,75 kg cw -10 to 40 °C 0,75 kg cw -10 to 40 °C 0,75 kg cw/ccw Pumps include mounting bracket and filter. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Nominal voltage Flow [l/min] 16 Continuous operation Intermittent operation 14 G 24 / 08 - 30 Watt rev. G 12/08-30 Watt G 24/08-30 Watt G 24/08-30 Watt rev. 12 10 503... Nominal motor power DC Reversible Model type 8 6 4 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 2 0 100 80 Vacuum rel. [%] 60 40 20 0 0,5 1,0 1,5 Pressure [bar] 18 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Rotary Vane Pump G 08-T 36 l/min 1,4 bar 93 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number G 12/08-T 50241 connected in series 17 l/min G 24/08-T 50238 connected in series 19 l/min 93 % G 12/08-T 50241 connected in parallel 33 l/min 1,4 bar 84 % 93 % G 24/08-T 50238 connected in parallel 36 l/min 1,4 bar 84 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Permanent magnet 12 V DC 4,0 A 5,0 A IP40 Ball bearing Permanent magnet 12 V DC 4,0 A 8,0 A IP40 Ball bearing Permanent magnet 24 V DC 2,0 A 2,5 A IP40 Ball bearing Permanent magnet 24 V DC 2,0 A 4,0 A IP40 Ball bearing General Data Ambient temperature Weight Direction of rotation -10 to 40 °C 1,3 kg cw -10 to 40 °C 1,3 kg cw -10 to 40 °C 1,3 kg cw -10 to 40 °C 1,3 kg cw Max. flow Max. intermittent pressure Max. intermittent vacuum Pumps include mounting bracket (2x) and filter (2x). These pumps are not suitable for continuous operation. All listed values are measured at standard atmospheric conditions. Model key: Flow Curves Flow [l/min] 39 36 Intermittent operation 33 G 12 / 08 - T G 24/08-T 50238 Ps. G 12/08-T 50241 Ps. G 24/08-T 50238 Rs. G 12/08-T 50241 Rs. 30 27 24 50... DC Double headed Model type 21 18 15 12 9 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 6 3 0 100 80 Vacuum rel. [%] 60 40 20 0 0,5 1,0 1,5 Pressure [bar] 19 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Nominal voltage Rotary Vane Pump BL-G 085 M 8,5 l/min 450 mbar 50 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum BL-G 12/085 M 50209 8,5 l/min 450 mbar 150 mbar 50 % 15 % Electrical Data Motor type* Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Electrical connection Brushless DC 12 V DC 0,7 A 2,0 A IP00 Ball bearing Flex-Print connector, 11 poles, pitch 1,0 mm, top contact style General Data Ambient temperature Weight Direction of rotation -40 to 60 °C 0,15 kg cw/ccw * without electronics All listed values are measured at standard atmospheric conditions. Please contact Thomas if further information regarding electrical connection and electronics is required. Use provided mounting locations only. Do not allow force on either motor or pump head. Motor bearing can be damaged. Model key: Flow Curves Nominal voltage Flow [l/min] 9 Continuous operation Intermittent operation 8 BL-G 12/085 M BL - G 12/085 M 7 Brushless motor 6 Model type DC 5 50210 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation 4 3 2 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 1 0 50 40 Vacuum rel. [%] 30 20 10 0 100 200 300 400 500 Pressure [mbar] 20 Pin allocation: Pin 1 4,5 - 18 VDC Pin 2 Hall sensor 3 Pin 3 Hall sensor 1 Pin 4 Hall sensor 2 Pin 5 GND Pin 6 Motor winding 3 Pin 7 Motor winding 2 Pin 8 Motor winding 1 Option: Adaptor for Flex-Print connector to terminal board, part number 63003 BL-G 12/085 M 50210 including external electronics (63002) + adaptor (63003) for Flex-Print connector Rotary Vane Pump G 09 11 l/min 370 mbar 35 % Dimensions in mm (inch) Flow Max. pressure Max. vacuum Pneumatic Data Description Part number Max. flow Max. intermittent pressure Max. continuous pressure Max. intermittent vacuum Max. continuous vacuum G 12/09-6 B 50330 / 50544 11,0 l/min 370 mbar 200 mbar 32 % 20 % G 12/09-6 LC 50555 / 505521) 9,0 l/min 350 mbar 150 mbar 35 % 15 % G 24/09-6 LC 50554 / 505561) 9,0 l/min 350 mbar 150 mbar 35 % 15 % Electrical Data Motor type Nominal voltage Min. current consumption Max. current consumption Protection class Motor bearing Permanent magnet 12 V DC 0,7 A 1,8 A IP30 Ball bearing Permanent magnet 12 V DC 0,7 A 2,2 A IP20 Ball bearing / Sleeve bearing Permanent magnet 24 V DC 0,4 A 1,3 A IP20 Ball bearing / Sleeve bearing General Data Ambient temperature Weight Direction of rotation -20 to 50 °C 0,24 kg cw / ccw -20 to 50 °C 0,30 kg cw / ccw -20 to 50 °C 0,30 kg cw / ccw Mounting bracket (Option) 31911 / 319141) 31947 / 319141) All listed values are measured at standard atmospheric conditions. 1) Pump including EPDM-cover for sound reduction. For vacuum operation: change electrical polarity. For noise reduction: do not remove green cap. To optimise flow: remove green cap. Mounting on motor body only. Do not allow force on pump head. Model key: Flow Curves Flow [l/min] 12 G 12/09-6 B G 12/09-6 LC / G 24/09-6 LC Continuous operation Intermittent operation 11 10 50... Nominal voltage Number of vanes G 12 / 09 - 6 LC 9 DC 8 LC = Low-cost motor B = Standard motor Model type 7 6 5 4 3 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. 2 1 0 40 30 Vacuum rel. [%] 20 10 0 100 200 300 400 Pressure [mbar] 21 Stock programme Current consumption: Min.: at open flow Max.: at max. intermittent operation Wiring diagram (Brushless DC motor) Pin 1 Function V Supply Colour Red Pin 2 Pin 3 Ground Speed control Black White Pin 4 Tacho out Green Control 12 VDC (max. voltage range: 10..18 VDC) 24 VDC (max. voltage range: 10..28 VDC) Ground for Vsupply (PIN 1) and Speed Control (PIN3) analog: 0..5 VDC (max. 28V) PWM: 6..20 kHz - 14..96% Speed voltage input threshold: 0,2 V 18 pulses per revolution Pulse time „LOW“: 195 µs Output level „LOW“: 0 / max. 0,5 V Output level „HIGH“: min. 4 V / max. 5 V Speed Input Speed Output +6V +6V 74HC... 3K9 FG Vin 10K 68K Optional: Adapter for 2-wire duty incl. potentiometer for speed adjustment 56K 56K 470p 100n Speed Output signal V 5 0 195µs Options / Accessories P/N 29011932 Adapter for BLDC motor 4-2 wire w/ manual speed control 12 V DC “red” P/N 29011933 Adapter for BLDC motor 4-2 wire w/ manual speed control 24 V DC “black” 22 t Notes 23 Gardner Denver Thomas GmbH Printed in Germany. Art.-Nr.: 17000115 01/2015 Livry-Gargan-Str. 10 · 82256 Fürstenfeldbruck · Germany Phone: +49 8141 2280 0 · Fax: +49 8141 8892136 e-Mail: [email protected] · http://www.gd-thomas.com