Short Form Catalogue - Centre
Transcription
Short Form Catalogue - Centre
Front cover This PDF is intended for on-screen viewing. A PDF formatted for A4-folded-to-A5 booklet printing is also available from our download centre at www.siemens.com.au/rail-components. Rail Automation Short-Form Catalogue November 2014 TTTNPSFC Issue 26.0 For More Information For More Information Contact Siemens Rail Automation W: http://www.siemens.com.au/rail-components Australia Siemens Rail Automation Pty Ltd T: +61 1300 724 518 ABN 78 000 102 483 E: [email protected] Indonesia P.T. Siemens Indonesia T: +62 21 2754 3470 E: [email protected] Malaysia Siemens Malaysia Sdn. Bhd T: +60 3 7952 5075 E: [email protected] New Zealand Siemens (N.Z.) Limited. Company Number 318303 T: +64 (0) 9 580 5500 E: [email protected] Thailand Siemens Limited T: +66 (0) 2 718 2170 E: [email protected] Download Documents from the Download Centre (www.siemens.com.au/downloadcentre) Get a variety of documents, and keep them up-to-date, from the Download Centre. Basic documents— such as datasheets for product overviews or bulletins for advice—are immediately accessible; detailed documents—such as instruction sheets for “how to” procedures, and manuals for product usage and firstline maintenance etc—require a one-off on-line registration. Siemens Rail Automation Short-Form Catalogue Document CI: TTTNPSFC Issue: 26.0 Date of Issue: November 2014 Copyright Transmittal, reproduction, dissemination or editing of this document is prohibited. Use of this document’s contents and communication thereof to others without express authorization is also prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. © Siemens Rail Automation Pty Ltd 2014. All rights reserved. ABN 78 000 102 483 CONTENTS SECTION PAGE For More Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1 Signals 1.1 Colour Light and LED Signals 1.1.1 Complete Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Sigmaguard Style L Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sigmaguard Style LS Searchlight Replacement Signal . . . . . . . . . . . . . . . Sigmaguard LED Style U2L Colour Light Signals . . . . . . . . . . . . . . . . . . . Sigmaguard LED Style Close-up Signals . . . . . . . . . . . . . . . . . . . . . . . . . . 11 11 11 12 1.1.2 Signal Lamps and LED Retrofit Kits . . . . . . . . . . . . . . . . . . . . . . . . . 12 VELCORP/GEMS Long Life Signal Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Sigmaguard Rear-Access Retrofit Kit for LED Signals . . . . . . . . . . . . . . . . 12 1.2 Subsidiary Signals Sigmaguard LED Style L Junction Route Indicator . . . . . . . . . . . . . . . . . . Sigmaguard LED Position Light Junction Indicator, PJ2L . . . . . . . . . . . . . Sigmaguard LED Style L Position Light Shunt Signal . . . . . . . . . . . . . . . . Sigmaguard LED Theatre Route Indicator . . . . . . . . . . . . . . . . . . . . . . . . Sigmaguard LED Banner Repeat Signal . . . . . . . . . . . . . . . . . . . . . . . . . . Sigmaguard LED Guard’s Indicator and Retrofit Kits . . . . . . . . . . . . . . . . Sigmaguard LED Running Turnout Signal . . . . . . . . . . . . . . . . . . . . . . . . Sigmaguard LED Repeater Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LED Turnout Repeat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sigmaguard LED Stencil Route Indicator . . . . . . . . . . . . . . . . . . . . . . . . . Sigmaguard LED Marker Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sigmaguard Specialist LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 13 13 13 13 14 14 14 14 15 15 15 1.3 Masts and Hardware Sigmaguard Easy Access Signal Masts . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Sigmaguard Rotatable Top of Post Signal Mount . . . . . . . . . . . . . . . . . . 16 2 Points 2.1 Electric Point Machines Switchguard One Trough S 700 V Points Operating System . . . . . . . . . . Switchguard M3A Mk II Electric Point Machine (Emergency Hand Crank) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switchguard M23A MkII Electric Point Machine (Dual Control) . . . . . . . Switchguard Series 84M MkIII Point Machine (Universal) . . . . . . . . . . . . Switchguard S 700 K Point Machine ...NEW . . . . . . . . . . . . . . . . . . . . Switchguard SURELOCK ...NEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clearguard Circuit Controller Retrofit Kit . . . . . . . . . . . . . . . . . . . . . . . . . 17 17 17 17 18 18 18 2.2 Pneumatic Point Controllers ES Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 A Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. CONTENTS SECTION PAGE 2.3 Point Locks and Detection Switchguard HLM MkII Series Point Locks with Detector ...Improved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switchguard HM MkII Series Point Detectors ...Improved . . . . . . . . . Circuit Controller Style U5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switchguard ELP 319 End Position Detector ...NEW . . . . . . . . . . . . . . 19 19 20 20 2.4 Mechanical Point Equipment Switchguard T21M Point Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Switchguard Derail & Crowder ...Improved . . . . . . . . . . . . . . . . . . . . 21 2.5 Bearers Switchguard In-Bearer Point Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3 Relays Style Q Plug-in Relays Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.1 Neutral Line Relays, Non-Immune Relay Style QN1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QNN1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QND2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QNND1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QNM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QNCD1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QNCM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 23 23 23 24 24 24 24 3.2 Neutral AC-Immune Line Relays Relay Style QNA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Relay Style QNNA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.3 Neutral Slow Acting, AC-Immune Line Relays Relay Style QSPA1 Slow Operate Track Circuit Relay . . . . . . . . . . . . . . . Relay Style QSRA1 Slow Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QSRA4 Slow Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QNNS1 Slow Operate and Release . . . . . . . . . . . . . . . . . . . . 25 25 25 25 3.4 Biased AC-Immune Line Relays Relay Style QBA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Relay Style QBBA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Relay Style QBCA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3.5 Magnetic Latched Line Relays Relay Style QL1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.6 Track Relays Relay Styles QT1 & QT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QTA2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QBT1 for Motor Current Proving . . . . . . . . . . . . . . . . . . . . . . Relay Style QTM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 26 26 26 3.7 Lamp Proving Relays Relay Style QECX20 LED Lamp Proving . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QN3 Lamp Proving Multilamp circuits . . . . . . . . . . . . . . . . . Relay Style QEC1 Slow Release Lamp Proving 12V lamps . . . . . . . . . . . . Relay Style QSR3 Slow Release Lamp Proving . . . . . . . . . . . . . . . . . . . . . Relay Style QECX5 Slow Release Lamp Proving 110 Vac 18 + 3.5W Twin Filament Lamp . . . . . . . . . . . . . . . . . . . . . 6 26 27 27 27 27 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. CONTENTS SECTION PAGE Relay Style QECX7 Lamp Proving 10 Vac 18 + 3.5W Twin Filament Lamp . . . . . . . . . . . . . . . . . . . . . . Relay Style QECX8 Lamp Proving 110 Vac 60W Incandescent . . . . . . . . Relay Style QUCX1 Lamp Proving 110 Vac JRI . . . . . . . . . . . . . . . . . . . . . Relay Style QNX1 Lamp Proving 35 W Shunt Signal . . . . . . . . . . . . . . . . Relay Style QECX 1,11,15 & 19 Lamp Proving for SL34 or SL35 110 Vac Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Style QEECF1 Lamp Proving 12 V Crossing Signals . . . . . . . . . . . . 27 27 27 27 27 28 3.8 Timers Timer Style QTD1 Dual Non-Vital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timer Style QTD4 Delay to Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timer Style QTD5 Delay to Pick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timer Style QCJ1 Non Vital Point Machine . . . . . . . . . . . . . . . . . . . . . . . 28 28 28 28 3.9 Transformer-Rectifier Units Transformer-Rectifier Style QXR1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 3.10 Special-Purpose Units Style QR Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Relay Unit Style QAC1 Battery Charge Fail Detector . . . . . . . . . . . . . . . . 29 Relay Unit Style QAJTC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.11 AC Relays Relay Style QNHX1 Interface to WESTLOCK and SSI . . . . . . . . . . . . . . . . 29 Relay Style QWCX1for Point Machine Motor Proving . . . . . . . . . . . . . . . 29 Relay Style QNHCX1 Interface to WESTLOCK and SSI . . . . . . . . . . . . . . . 29 3.12 Relay Plug Board Relay Plug Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 5 Train Detection 5.1 Audio Frequency Overlay Track Circuits Clearguard Intelligent Processor Island Track Circuit (IPITC) . . . . . . . . . . Clearguard Phase Shift Overlay 4000 (PSO 4000) . . . . . . . . . . . . . . . . . . Wayguard PSO GCP 4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clearguard Series Overlay Circuit Track Circuit (SOTC) . . . . . . . . . . . . . . 31 31 31 31 5.2 Track Feed Sets Style WA15Q Track Feed Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Style R5-9 AC-Immune Track Feed Set . . . . . . . . . . . . . . . . . . . . . . . . . . . WESTRAK Track Feed Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WESTRAK Diode Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 32 32 32 5.3 Impedance Bonds High Current Impedance Bonds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.4 Accessories Style TD4 Track Disconnection Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.5 Jointless Track Circuit Equipment Clearguard TCM 100 Track Vacancy Detection System ...NEW . . . . . . 33 Clearguard FS2550 Jointless Track Circuit . . . . . . . . . . . . . . . . . . . . . . . . 33 5.6 Relay Track Circuit VT1 ac Track Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.7 Axle Counters Clearguard ACM200 Axle Counting System . . . . . . . . . . . . . . . . . . . . . . 34 Clearguard ACM100 Axle Counting System . . . . . . . . . . . . . . . . . . . . . . 34 Short-Form Catalogue Issue 26.0 7 CONTENTS SECTION PAGE 6 Trainstops 6.1 Trainstops (Trip Type) Trainguard Trainstop, Style JA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trainguard Trainstop, Style JAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trainguard Trainstop Power Unit, Style EH1 . . . . . . . . . . . . . . . . . . . . . . Clearguard Circuit Controller Retrofit Kit . . . . . . . . . . . . . . . . . . . . . . . . . 35 35 35 35 9 Level Crossing Protection 9.1 Flashing Lights & Accessories Wayguard Level Crossing Light Crossarms . . . . . . . . . . . . . . . . . . . . . . . Sigmaguard LED Crossing Signals & Retrofit Kits . . . . . . . . . . . . . . . . . . Sigmaguard LED Barrier Arm Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wayguard SAFEFLASH—Level Crossing Flasher . . . . . . . . . . . . . . . . . . . Wayguard SSCC III Plus—Solid-State Crossing Controller . . . . . . . . . . . . 37 37 37 37 38 9.2 Barrier Mechanisms Wayguard Circuit Controller and Motor Retrofit Kits . . . . . . . . . . . . . . . 38 Wayguard S-60 Level Crossing Barrier Mechanism . . . . . . . . . . . . . . . . . 38 Wayguard S-20/S-40 to S-60 Retrofit Kit ...NEW . . . . . . . . . . . . . . . . . 38 9.3 Barrier Wayguard Level Crossing Barrier Arms . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Wayguard Pre-Dressed Level Crossing Barrier Arms ...NEW . . . . . . . . 39 9.4 Warning Bells Wayguard Level Crossing Bell—Solid State . . . . . . . . . . . . . . . . . . . . . . 39 9.5 Grade Crossing Predictors Wayguard Grade Crossing Predictors—4000 Series (GCP 4000) . . . . . . Wayguard Motion Sensor 4000 (MS 4000) ...NEW . . . . . . . . . . . . . . Wayguard Accessories—Grade Crossing Predictors . . . . . . . . . . . . . . . . Wayguard DC Shunting Enhancer Panel . . . . . . . . . . . . . . . . . . . . . . . . . Wayguard PSO GCP 4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 40 41 41 42 9.6 Installations Crossing in a Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 10 Control and Signalling Systems 10.1 Computer-Based Interlockings Interlocking Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trackguard WESTRACE MkII Interlockings . . . . . . . . . . . . . . . . . . . . . . . . Trackguard WESTRACE Object Controllers . . . . . . . . . . . . . . . . . . . . . . . Trackguard WESTRACE GCSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trackguard WESTRACE GSIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Controlguide MoviolaW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trackguard WESTLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trackguard Solid-State Interlocking (SSI) . . . . . . . . . . . . . . . . . . . . . . . . Vital Signal Logic Simulator (VSLS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 43 43 44 44 44 44 45 45 10.2 Telemetry Systems Controlguide WESTRONIC S2 (System Two) . . . . . . . . . . . . . . . . . . . . . . Controlguide WESTRONIC S2 Telemetry Scanner Modules . . . . . . . . . . Controlguide S2/DIP42 Digital Input Module . . . . . . . . . . . . . . . . . . . . . Controlguide S2/DIP43 Digital Input Module . . . . . . . . . . . . . . . . . . . . . Controlguide S2/DOP42 Digital Output Module . . . . . . . . . . . . . . . . . . . 8 45 45 46 46 46 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. CONTENTS SECTION PAGE Controlguide S2/DOP43 Digital Output Module . . . . . . . . . . . . . . . . . . . Controlguide S2/ALC Alarm & Line Changeover . . . . . . . . . . . . . . . . . . . Controlguide WESTRONIC S2/PSU Power Supply Module . . . . . . . . . . . . Controlguide S2/SLC Serial Line Converter (RS232-RS422) . . . . . . . . . . . Controlguide S2/VFC45 Voice Frequency Modem CCITT V.23 FSK . . . . . Vital and Non-Vital Communication Systems . . . . . . . . . . . . . . . . . . . . . HD/Link System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethernet Spread-Spectrum Radio (ESSR) . . . . . . . . . . . . . . . . . . . . . . . . . Wayside Access Gateway (WAG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CNA2000 Network Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 46 46 46 47 47 47 47 47 48 10.3 Train Control Equipment Controlguide Rail 9000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Controlguide WESTCAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 10.4 Automatic Train Control and Protection Trainguard WESTECT II ATP (Automatic Train Protection) ...Improved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trainguard ETCS ...NEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trackguard Train Sentinel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . End of Train Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Head of Train Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 49 49 49 50 10.5 Automatic Equipment Identification (AEI) Systems Transcore Automatic Equipment Identification . . . . . . . . . . . . . . . . . . . . Trackguard WESTECT Portable Transponder Reader Module (PTRM) . . . Transcore AI1200 Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transcore AR2200 RF Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transcore Encompass 4 RFID Tag Reader . . . . . . . . . . . . . . . . . . . . . . . . . Transcore AA3233-004 Heavy Rail Antenna . . . . . . . . . . . . . . . . . . . . . . Transcore AA3234 Light Rail Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . Transcore AA3110 Parapanel Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . Transcore AT5118 Rail Harsh Environment Rail Tag . . . . . . . . . . . . . . . . Transcore AT5413 Hardened Rail Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . Transcore PT5780 Permissions Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transcore AT5720 Check Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transcore AP4118 Rail Tag Programmer . . . . . . . . . . . . . . . . . . . . . . . . . 50 50 50 50 51 51 51 51 52 52 52 52 53 10.6 Fault Monitoring and Data Logging Wayguard SEAR II Event Analyser and Recorder . . . . . . . . . . . . . . . . . . . Wayguard SEAR II Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Axle Counter SEAR Island Interface (ACSI) . . . . . . . . . . . . . . . . . . . . . . . . Wayguard Argus Event Recorder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Condition Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 53 53 53 54 10.7 Integrated Communication and Control Systems (ICSS) Controlguide SystematICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Controlguide SystematICS RailSCADA . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 11 Accessories 11.1 Terminal Blocks RSA Double-Row Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Short-Form Catalogue Issue 26.0 9 CONTENTS SECTION PAGE 11.2 Lightning and Surge Arresters Surge Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Track Circuit Surge Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surge Reduction Filter (SRF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Gap Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clear-Comm Lightning Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heavy Duty Equalisers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 56 56 56 56 57 11.3 Resistors Sealed Resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Resistance Units—Adjustable, Fixed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 11.4 Tools Insulated Terminal Wrenches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relay Tag Crimping Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contact Removal Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Barrier Mechanism Toolkit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Track Circuit Short Finder ...Improved . . . . . . . . . . . . . . . . . . . . . . . . 57 58 58 58 58 13 Services 13.1 Training Railway Signalling Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 13.2 Technical Documentation Technical Documentation Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 13.3 Refurbishments and Design Q Relay Refurbishment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Electro-mechanical Refurbishment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Point Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 10 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 1 SIGNALS 1.1 Colour Light and LED Signals 1. Signals 1 1.1 Colour Light and LED Signals 1.1.1 Complete Signals Sigmaguard Style L Signal Datasheet 1A-12 Mainline LED signal: • one to four aspects • three beam patterns • red, yellow, green, white or blue aspects • 110 Vac or 12 Vdc operation • lamp proving option available Sigmaguard Style LS Searchlight Replacement Signal Datasheet 1A-16 Multiple aspect LED signal to replace searchlight signals: • two or three aspects • three beam patterns • ac or dc operation • uses existing circuits and wiring Sigmaguard LED Style U2L Colour Light Signals Datasheet 1A-19 Underground, yard or subsidiary LED signal: • one to four aspects • red, yellow, green, white or blue • narrow width—165 mm • ideal for underground, yard or subsidiary use Short-Form Catalogue Issue 26.0 11 1 1.2 SIGNALS Subsidiary Signals Sigmaguard LED Style Close-up Signals Datasheet 1A-20 Used for any short sighting distance application—co-acting signals, underground, and other close up uses. Can be operated in parallel with main signals. 1.1.2 Signal Lamps and LED Retrofit Kits VELCORP/GEMS Long Life Signal Lamps Datasheet 1A-18 SL17T Direct replacement for existing signalling lamps: • available in all standard signalling lamp styles (including SL17 with pigtail leads) • lifetime in excess of three times standard signalling lamps • precisely-aligned filament for accurate focus • very low rate of light output degradation Sigmaguard Rear-Access Retrofit Kit for LED Signals Datasheet 1A-22 Rear-Access Retrofit Kit 1.2 Maintain 200 mm signals safely: • all future signal module maintenance from rear of signal • suits most 200 mm signals, eg R2, R4 and ML • suits all Invensys Rail RM4 LED signal modules • hoods mount as before • one retrofit kit contains parts for all approved signal types Subsidiary Signals Sigmaguard LED Style L Junction Route Indicator Datasheet 1C-5 LED Style L Junction Route Indicator that mounts to the top of a colour light signal to indicate when the signal is cleared for a diverging route: • medium range optics • five 127 mm lunar white LED lamp modules • can be inclined 45° to the left or right 12 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 1 1.2 SIGNALS Subsidiary Signals 1 Sigmaguard LED Position Light Junction Indicator, PJ2L Datasheet 1C-14 LED style Position Light Junction Indicator: • can indicate up to six different directions • medium or long range optics • five 127 mm lunar white LED lamp modules for each indicated direction Sigmaguard LED Style L Position Light Shunt Signal Datasheet 1C-6 Short range signal: • 127 mm LED lamp modules • two or three aspects • red, yellow or white • optional mask • stencil route indicator can be fixed to top of case Sigmaguard LED Theatre Route Indicator Sigmaguard LED Dynamic Speed Indicator Datasheet 1C-10 LED theatre route or dynamic speed indicator: • can display 2 full size or 4 half size characters simultaneously • up to 6 characters in a standard case or up to 10 characters an extended case • white LEDs for ultra reliability Sigmaguard LED Banner Repeat Signal Datasheet 1C-11 An electronic equivalent to a semaphore repeat signal: • signal uses white LEDs on a black bezel • can replace two aspect colour light signals without changing wires or circuits • 110 Vac or 12 Vdc operation • banner display can be discerned at distances greater than 400 metres Short-Form Catalogue Issue 26.0 13 1 1.2 SIGNALS Subsidiary Signals Sigmaguard LED Guard’s Indicator and Retrofit Kits Datasheet 1C-12 210 mm LED guard’s indicator with same display as existing guard’s indicators. Sigmaguard LED Running Turnout Signal • Complies with Rail Access Corporation Signalling Equipment Specifications SC 07 10 00 00 SP, version 2.1, April 2000 • Indicates left or right turnout Sigmaguard LED Repeater Signal • Complies with Rail Access Corporation Signalling Equipment Specifications SC 07 10 00 00 SP, version 2.1, April 2000 LED Turnout Repeat • Complies with Rail Access Corporation Signalling Equipment Specifications SC 07 10 00 00 SP, version 2.1, April 2000 14 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 1 1.3 SIGNALS Masts and Hardware 1 Sigmaguard LED Stencil Route Indicator Datasheet 1C-15 A short range subsidiary signal: • capable of displaying two characters independently or one symbol occupying the full width of the display • vertical or horizontal mounting Sigmaguard LED Marker Light Datasheet 1C-16 LED Retrofit kits for Victorian Rail Case B116: • hermetically encapsulated LEDs and power supply • multiple LEDs and parallel circuitry • wide voltage range Sigmaguard Specialist LED Indicators Datasheet 1C-17 Any symbol, any character and any standard colour. • 140, 200 and 300 mm circular modules • single- and multi-aspect cases suit standard mounts • long service life with high reliability LEDs and power supplies • high intensity • wide viewing angle • low power consumption and wide voltage range 1.3 Masts and Hardware Sigmaguard Easy Access Signal Masts Datasheet 1E-6 Purpose designed signal mast to place signals where they can be accessed from the safety of the ground. • Makes maintenance tasks safer and faster. • Lower and raise by one person • Removes EH&S working at heights risks. Never need to climb the mast • Separates maintenance crews from overhead electrical wiring • Eliminates ladders and protective cages • Simplifies installation. Short-Form Catalogue Issue 26.0 15 1 1.3 SIGNALS Masts and Hardware Sigmaguard Rotatable Top of Post Signal Mount Datasheet 1E-7 Provides safe access to Easy-Access and standard post mounted signals. • Full front and rear ground access to signals on Easy Access Mast • Front and rear platform access to signals on standard masts • Precision return—locks to aligned angle after access • Single bolt tilt adjustment up 20°, down 10° • Secure, high wind proof collar clamp suits 140 mm masts (adaptable to 114 mm masts) • Suits Style L, U2L and other top of post signals • Corrosion resistant 16 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 2 2.1 POINTS Electric Point Machines 2. Points 2.1 Electric Point Machines 2 Switchguard One Trough S 700 V Points Operating System Integrates the proven S 700 V point machine, the locking and the rodding into a single hollow sleeper. • • • • • • • • Removes points operating equipment from between the sleepers. Improved running dynamics over points Reduced lifecycle costs Simple, proven and reliable claw lock rail-head locking or advanced VAE Spherolock locking system. Low maintenance intervals with less maintenance and lower lifecycle costs. Permits automatic tamping throughout the turnout. Improves track stability. Suitable for single drive turnouts, multiple drive turnouts and swing nose crossings Switchguard M3A Mk II Electric Point Machine (Emergency Hand Crank) Datasheet 2A-12 A rugged and dependable point machine for non-trailable applications: • for main line or yard operation of single switch, double slip switches, catch points and cross-overs • 152 mm standard stroke (165 mm extended) • ac or dc operation • hand crank for emergency operation Switchguard M23A MkII Electric Point Machine (Dual Control) Datasheet 2A-12 A rugged and dependable dual-control point machine for non-trailable applications: • for main line or yard operation of single switch, double slip switches, catch points and cross-overs • 152 mm standard stroke • ac or dc operation • hand throw lever Switchguard Series 84M MkIII Point Machine (Universal) Datasheet 2A-8 Builds on the features of the 84M universal point machine: • improved end-of-stroke locking • new clutch with improved access, maintenance and reliability • RSA or spring clamp cable termination • detector and throw bars can be grouped for in-bearer applications • upgrade kits converting MkI machines to MkIII are available Short-Form Catalogue Issue 26.0 17 2 2.2 POINTS Pneumatic Point Controllers Switchguard S 700 K Point Machine ...NEW Datasheet A19100-V100-B802-V3-7600 For setting points with external locking. Economical and versatile, making it suitable for use in mass transit and mainline transport with points of all types and gauges. • Economical operation • High level of availability • Universal application • Robust, compact design • Long service life, long maintenance intervals, short out-of-service periods Switchguard SURELOCK ...NEW Datasheet A19100-V100-B951-X-7600 Point drive system suitable for use in mass transit and mainline transport. • • • • Mechanically locks the points on completion Detects Points are closed and locked in correspondence Tail cables connected using plug-coupler system Mountable between or beside running rails Clearguard Circuit Controller Retrofit Kit Datasheet 2A-5 A switch type circuit controller for rejuvenating older M2, M22, M3A and M23A point machines. Directly replaces the old type drum controllers which are difficult to set and might be near the end of their service life. 2.2 Pneumatic Point Controllers ES Valve Datasheet 2C-2 Directly replaces life-expired Style E controllers for pneumatic point control. Same fixings, same connections, same operation—but with modern pneumatic control components. 18 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 2 POINTS 2.3 Point Locks and Detection A Valve Controller for pneumatic points control. 2 2.3 Point Locks and Detection Switchguard HLM MkII Series Point Locks with Detector ...Improved Datasheet 2D-6 Combined lock and detector for manually operated points, ground frames or derails: • 0, 1 or 2 detector slides • 2-slide models prove normal and reverse positions • optional external hand operated emergency release lever Upgraded lock detection switch. Meets AREAM recommendations for a facing point lock. Lock Bar Retrofit Kit for upgrading older installations but does not meet AREMA recommendations. Switchguard HM MkII Series Point Detectors ...Improved Datasheet 2D-6 Low profile, one to four slide point detectors. Upgraded point detection switch. Short-Form Catalogue Issue 26.0 Series Feature HMX HM one or two slide point detection in confined spaces. one to four slide point detection for main or secondary line points. 19 2 2.4 POINTS Mechanical Point Equipment Circuit Controller Style U5A Datasheet 2D-3 Dual-Switch detector for points, facing point lock and other sliding equipment: • One or two independent positional detectors • Fine, worm-drive, adjustment • Minimal maintenance (no lubrication) • Large adjustment range • Low profile — mounts below structural gauge • Reliable, common style switch Switchguard ELP 319 End Position Detector ...NEW Datasheet A19100-V100-B927-V1-7600 Detects the end positions of points (centre lock, high-speed, manually operated, spring return), mechanical latching devices, movable frogs and wing rails. Can also be used to detect the locking function, indicate trailing operations, and detect gauge narrowing. • Slide stroke continuously adjustable from 30 to 190mm. • Fitted without modification to all rail profiles 2.4 Mechanical Point Equipment Switchguard T21M Point Machine Datasheet 2H-1 A simple, manually-operated, non-trailable point machine with facing point lock. A single hand throw lever operates the lock and throws the points. Options: • reflective banner to indicate position of points • locking in the reverse position (in addition to the normal position) • electrical detection of point position and locking • electrical release • locking of the hand throw lever with safeworking padlocks, standard padlocks, or miniature Annett locks 20 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. Switchguard Derail & Crowder 2 POINTS 2.5 Bearers ...Improved Datasheet 2H-2 D150 Derail—Protects against runaway vehicles entering an operational line. C150 Crowder—Used in conjunction with the D150 Derail to prevent rerailing that can occur in some conditions (recommended) Concrete Bearer Kits — everything you need but the thruster, including derail, crowder, 2 custom concrete bearers, rodding and all fixings to suit most drives, rail gauges and rail sizes. MkII Enhancements • more effectively handle vehicles at higher speeds or fitted with bogie wheels • readily retrofitted to MkI units by replacing single parts in the derail and crowder 2.5 Bearers Switchguard In-Bearer Point Drive Datasheet 2I-1 A comprehensive bearer, point drive and rail head locking solution. Encases all rodding, detection and point drive within a high strength rolled steel bearer: • fully machine-tampable • clawlock rail head locking • drive from existing hydraulic, pneumatic or mechanical equipment, or from 84 Series point machine Short-Form Catalogue Issue 26.0 21 2 2 2.5 22 POINTS Bearers © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 3 RELAYS 3.1 Neutral Line Relays, Non-Immune 3. Relays Relays not listed below are available to special order. Please discuss your requirements with our sales staff. Style Q Plug-in Relays Overview Datasheet 3A 3 General information. 3.1 Neutral Line Relays, Non-Immune Relay Style QN1 Datasheet 3B-1 A single-wound dc neutral line relay that complies with BR Specification 930. Relay Style QNN1 Datasheet 3B-2 A twin single-wound dc neutral twin line relay that complies with BR Specification 960. Relay Style QND2 Datasheet 3B-3 A dc neutral line relay that complies with BR Specification 930. It is identical to the QN1 in all respects except that the coil has two windings, each of which will operate the relay. The windings can operate independently, in parallel or be connected in series to provide a higher resistance at the same voltage. Relay Style QNND1 Datasheet 3B-4 A twin dc neutral line relay that complies with BR Specification 960. It is identical to QNN1 in all respects except that each coil has two windings, either of which will operate the relay. The windings can operate independently, in parallel or be connected in series to provide a higher resistance at the same voltage. Short-Form Catalogue Issue 26.0 23 3 3.2 RELAYS Neutral AC-Immune Line Relays Relay Style QS2 Datasheet 3B-5 A single-wound dc neutral line relay designed to minimise power consumption. The 24 and 50 volt versions are intended for operation over very long lines and feature higher normal minimum release to provide added protection against holding up on stray voltages. Relay Style QNM1 Datasheet 3B-6 A single-wound dc neutral line relay that complies with BR Specification 930 except for the contacts which are silver cadmium oxide instead of the standard signalling contacts. Relay Style QNCD1 Datasheet 3B-7 A dc neutral line contactor relay fitted with two independent windings, either of which can operate the relay. The windings can operate independently, in parallel or be connected in series to provide a higher resistance at the same voltage. Two heavy duty front contacts (complete with arc quench magnets), rated up to 15 amps at 110 Vdc. Relay Style QNCM1 Datasheet 3B-8 A dc neutral line contactor relay fitted with two heavy duty front contacts (complete with arc quench magnets) rated up to 15 amps at 110 Vdc. The remainder of the contacts are metal to metal (silver cadmium oxide) rated at 6 amps. These contacts are weld resistant but not non-weldable. 3.2 Neutral AC-Immune Line Relays Relay Style QNA1 Datasheet 3C-1 A single-wound dc neutral line relay like the QN1 but with additional immunity to false operation by the application of up to 1000 Vac at 50 Hz. Complies with BR Specification 931. Relay Style QNNA1 Datasheet 3C-2 A twin single-wound dc neutral line relay like the QNN1 but with additional immunity to false operation by the application of up to 1000 Vac at 50 Hz. Complies with BR Specification 966, appendix F6. 24 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 3 3.3 3.3 RELAYS Neutral Slow Acting, AC-Immune Line Relays Neutral Slow Acting, AC-Immune Line Relays Relay Style QSPA1 Slow Operate Track Circuit Relay Datasheet 3D-1 A single-wound dc neutral slow operate ac-immune relay that complies with BR Specification 933. Relay Style QSRA1 Slow Release Datasheet 3D-2 A single-wound dc neutral slow release ac-immune relay that complies with BR Specification 934. Relay Style QSRA4 Slow Release Datasheet 3D-3 A single-wound dc neutral slow release ac-immune relay that provides a considerably longer release time than QSRA1. The release time is in excess of 550 msec when energised at 80% of nominal working voltage. Relay Style QNNS1 Slow Operate and Release Datasheet 3D-4 A twin single-wound dc neutral slow operate and release relay that complies with BR Specification 963. 3.4 Biased AC-Immune Line Relays Relay Style QBA1 Datasheet 3E-1 A single-wound dc-biased ac-immune relay that complies with BR Specification 932. Relay Style QBBA1 Datasheet 3E-2 A twin single-wound dc-biased ac-immune relay that complies with BR Specification 961. Relay Style QBCA1 Datasheet 3E-3 A single-wound dc-biased ac-immune contactor that complies with BR Specifications 943 and 966, Appendix F4 according to contact layout. Identical to the QBA1 except: • the four standard contacts in the ‘C’ stack are replaced with two heavy duty contacts, • the four contacts in the ‘B’ stack are replaced with magnetic blowouts for the heavy duty contacts. Short-Form Catalogue Issue 26.0 25 3 3 3.5 RELAYS Magnetic Latched Line Relays 3.5 Magnetic Latched Line Relays Relay Style QL1 Datasheet 3F-1 A dc magnetically latched relay that complies with BR Specification 935. 3.6 Track Relays S Relay Styles QT1 & QT2 Datasheets 3G-1+2 A dc neutral track relay that complies with BR Specification 938. Also available with two back contacts which are additional to the specification requirement for two front contacts only. Several other variants to suit local requirements are available. Relay Style QTA2 Datasheet 3G-3 A dc neutral track relay that complies with BR Specification 939 or 966, Appendix F2. Also available with two back contacts which are additional to the specification requirement for two front contacts only. Relay Style QBT1 for Motor Current Proving Datasheet 3G-4 A dc-biased track relay that complies with all general requirements of BR Specifications 938 and 932 as far as they are applicable. Relay Style QTM1 Datasheet 3G-5 A dc neutral track relay similar to QT1 but with metal to metal (silver cadmium oxide) back contacts. These back contacts (rated at 6 amps) are weld resistant but not non-weldable. 3.7 Lamp Proving Relays The QECX20 is specifically designed for LED signals. Other relays were designed for incandescent signals. Some are usable with LED signals. Relay Style QECX20 LED Lamp Proving Datasheet 3H-11 An ac lamp proving relay for LED signals. 26 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 3 RELAYS 3.7 Lamp Proving Relays Relay Style QN3 Lamp Proving Multilamp circuits Datasheet 3H-1 A dc lamp proving relay with no time delay. Typically used where individual lamp failure detection required in a multilamp circuit. Relay Style QEC1 Slow Release Lamp Proving 12V lamps Datasheet 3H-2 A dc slow release lamp proving relay that complies with BR Specification 940. The slow release is adequate to cover the transit time of the signal control relay. Relay Style QSR3 Slow Release Lamp Proving Datasheet 3H-3 A dc lamp proving relay. It can be provided with a full wave rectifier to facilitate use in AC lamp circuits. The slow release is adequate to cover the transit time of the signal control relay. Relay Style QECX5 Slow Release Lamp Proving 110 Vac 18 + 3.5W Twin Filament Lamp Datasheet 3H-4 An ac lamp proving relay for proving the main filament of a 10 Vac 18 + 3.5 watt twin filament lamp. The slow release is adequate to cover the transit time of the signal control relay. Relay Style QECX7 Lamp Proving 10 Vac 18 + 3.5W Twin Filament Lamp Datasheet 3H-5 An ac lamp proving relay for proving the main filament of a 10 Vac 18 + 3.5 watt twin filament lamp. No time delay results in the voltage drop being lower than that of the QECX5. Relay Style QECX8 Lamp Proving 110 Vac 60W Incandescent Datasheet 3H-6 An ac lamp proving relay for proving a single 110 V 60 Watt lamp. Relay Style QUCX1 Lamp Proving 110 Vac JRI Datasheet 3H-7 An ac lamp proving relay that complies with BR Specification 942 to prove the five lamps of a 110 Vac Junction Route Indicator Relay Style QNX1 Lamp Proving 35 W Shunt Signal Datasheet 3H-8 An ac lamp proving relay incorporating an internal rectifier. No time delay is provided to cover the operating time of other relays. Relay Style QECX 1,11,15 & 19 Lamp Proving for SL34 or SL35 110 Vac Lamps Datasheet 3H-9 An ac slow release lamp (SL34 or SL35) proving relay that complies with BR Specification 941. Short-Form Catalogue Issue 26.0 27 3 3 3.8 RELAYS Timers Relay Style QEECF1 Lamp Proving 12 V Crossing Signals Datasheet 3H-10 A twin dc operated tractive armature lamp proving relay specifically for use with road crossing signals. Supersedes relay style QECF1. 3.8 Timers Timer Style QTD1 Dual Non-Vital Datasheet 3J-1 A non-fail-safe slow operate electronic unit. Each of the independent electronic timers can operate several ‘Q’ style relays in parallel (must have the same nominal voltage). Timer Style QTD4 Delay to Drop Datasheet 3J-2 A safety-critical slow-release electronic unit. Provides a delay between the opening of a control contact and the subsequent release of a normally energised slave relay. Any failure will never increase the time by more than 20% of the settings. Timer Style QTD5 Delay to Pick Datasheet 3J-3 A safety-critical slow-to-pick electronic timing element and relay all within a single plug-in ‘Q’ relay enclosure. Timer Style QCJ1 Non Vital Point Machine Datasheet 3J-4 A non-fail-safe slow operate electronic timing relay with fast reset that meets the requirements of BR 949. Generally used for point machine protection. 3.9 Transformer-Rectifier Units Transformer-Rectifier Style QXR1 Datasheet 3K-1 A transformer-rectifier mounted in a ‘Q’ relay housing designed to operate a 50 Vdc relay from a 110 Vac 50 Hz line with immunity to false operation due to dc or line capacitance up to 1 F. 28 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 3 3.10 RELAYS Special-Purpose Units 3.10 Special-Purpose Units Style QR Units Datasheet 3M-1 Various special purpose assemblies of electronic components and small commercial relays mounted in plug-in ‘Q’ relay enclosures. 3 Relay Unit Style QAC1 Battery Charge Fail Detector Datasheet 3M-2 A battery charge fail detector designed to provide an alarm dependent on the voltage and current output of a battery charger. The 12/24 V version monitors chargers with these nominal output voltages and derives its power from the charger and battery. The 4 V version derives its power from an external plug pack. Relay Unit Style QAJTC1 Datasheet 3M-3 Contains an amplifier for the pick-up coil of the intermediate receiver of the Jointless Track Circuit System FS 2500. 3.11 AC Relays Relay Style QNHX1 Interface to WESTLOCK and SSI Datasheet 3N-1 An ac line relay that complies with BR Specification 966, Appendix F7. The relay is not dc immune. Relay Style QWCX1for Point Machine Motor Proving Datasheet 3N-2 A motor current proving relay designed to detect the failure of an ac point machine motor. Relay Style QNHCX1 Interface to WESTLOCK and SSI Datasheet 3N-3 An ac line relay that complies with BR Specification 966, Appendix F7 except for the contacts. The relay is designed to interface with solid-state interlocking circuitry. It is not dc immune. Short-Form Catalogue Issue 26.0 29 3 RELAYS 3.12 Relay Plug Board 3.12 Relay Plug Board Relay Plug Board Datasheet 3A For permanent mounting in relay cabinets: • insertable wiring connectors • keyed holes engage pins on relay base to ensure incorrect relay cannot be mounted. 4 30 SECTION 4 IS NOT IN USE. © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 5 TRAIN DETECTION 5.1 Audio Frequency Overlay Track Circuits 5. Train Detection 5.1 Audio Frequency Overlay Track Circuits Clearguard Intelligent Processor Island Track Circuit (IPITC) Datasheet Sb-06 A modulated audio frequency track circuit that can be overlaid on other ac or dc track circuits. Any of 12 frequencies can be selected. All in a single housing. Used for level crossing islands and other short track circuits. 5 Clearguard Phase Shift Overlay 4000 (PSO 4000) Datasheet 5A-4 An updated overlay track circuit directly compatible with PSO II and PSO III track circuits with new features: • minimised spares holding because each unit is frequency-configurable • separate transmitter, receiver, transceiver and crossing modules • greater flexibility with new frequencies and new codes • internal data log • internal stick logic in crossing module • improved safety with greater immunity for spurious frequency and modulation Wayguard PSO GCP 4000 Datasheet 9G-8 A complete PSO Crossing System—see section 9.5, page 42. Clearguard Series Overlay Circuit Track Circuit (SOTC) Datasheet Sd-5 An adjustable length audio frequency rail circuit intended primarily for obtaining release of electrically locked points The SOTC contains both transmitter and receiver and three frequencies are available: 5900 Hz, 10.0 Hz and 26.0 Hz. Short-Form Catalogue Issue 26.0 31 5 5.2 TRAIN DETECTION Track Feed Sets 5.2 Track Feed Sets Style WA15Q Track Feed Set Datasheet 5B-1 DC Track Feed set powered from 110 Vac 50 Hz supply. Style R5-9 AC-Immune Track Feed Set Datasheet 5B-2 Complies with BR Specification 867 suitable for dc track circuits operated by 25 kV 50 Hz overhead traction. When used with a 9 ohm ac-immune track relay to BR 966, Appendix F2, the track circuit will have immunity to traction interference up to 100 V 50 Hz and the feed set will withstand 430 V 50 Hz without damage. WESTRAK Track Feed Set Datasheet 5B-4 Occupies the space of two Q relays. WESTRAK Diode Unit 5.3 Impedance Bonds High Current Impedance Bonds Datasheet 5C-5 Designed to carry very high track currents—up to 4000 amps per rail for short duration. Models suit 50 Hz, jointless (1700 - 2600 Hz) and high voltage impulse tracks 32 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 5 TRAIN DETECTION 5.4 Accessories 5.4 Accessories Style TD4 Track Disconnection Box Datasheet 5D-1 A robust aluminium alloy die-cast box and cover to accommodate the transition and termination of track cables. Cable entry through hollow mast or through glands fitted in the base of the box. 5.5 Jointless Track Circuit Equipment 5 Clearguard TCM 100 Track Vacancy Detection System ...NEW Datasheet A19100-V100-B935-V1-7600 Maximum safety with fail-safe clear or occupied indication. High flexibility from modular architecture, connectivity to any type of interlocking or subsystem, & support for standard, centre-fed, or point track circuit. Reduced maintenance from maintenance-free modules & use of a single module type. Clearguard FS2550 Jointless Track Circuit Datasheet 5E-6 A family of Jointless Track circuit, transmitters, receivers, tuning units and intermediate receivers, compatible with FS2500, UM71 and TI21. Upgrade from FS2500 with enhanced reliability and performance. 1700, 2000, 2300 and 2600 Hz operating frequencies. 5.6 Relay Track Circuit VT1 ac Track Circuit Datasheet 5H-1 For dc traction areas where only one rail need be used for traction current return. Variant also available for double rail applications. Short-Form Catalogue Issue 26.0 33 5 5.7 TRAIN DETECTION Axle Counters 5.7 Axle Counters Clearguard ACM200 Axle Counting System Datasheet A19100-V100-B927-V1-7600 Smart track vacancy detection for cost-effective operations. Comprising maintenance-free modules, programmed via an ID plug and combined with an Ethernet bus and Clearguard ZP 43 E/V and ZP D 43 counting heads into a fail-safe axle counting system. • • • • • • Connection to electronic and relay interlockings HTML communication for attribute configuration, logging and diagnostics Modular, compact hardware Innovative diagnostic concept Deployment of Clearguard ZP 43 E/V and ZP D 43 counting heads Clearguard ACM100 Axle Counting System Datasheet A19100-V100-B927-X-7600 Smart track vacancy detection for cost-effective operations. Comprising maintenance-free Clearguard ACM 100 modules, programmed via an ID plug and combined with an Ethernet bus and Clearguard WSD wheel detectors into a fail-safe axle counting system. • • • • • • 34 Connection to electronic and relay interlockings HTML communication for attribute configuration, logging and diagnostics Modular, compact hardware Innovative diagnostic concept Low-cost Clearguard WSD wheel detector © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 6 TRAINSTOPS 6.1 Trainstops (Trip Type) 6. Trainstops 6.1 Trainstops (Trip Type) Trainguard Trainstop, Style JA Datasheet 6A-1 An electrically-controlled, pneumatically-operated trip arm trainstop that provides reliable protection against brake trip cock equipped trains moving beyond their authorised space. Trainguard Trainstop, Style JAH Datasheet 6A-2 An electrically-controlled, hydraulically-operated trip arm trainstop that provides reliable protection against brake trip cock equipped trains moving beyond their authorised space. Can also be remotely powered by an E1 Style Trainstop Power Unit. Trainguard Trainstop Power Unit, Style EH1 Datasheet 6A-4 An alternative power source for the JAH Style Trainstop. Moves the power supply away from the trainstop for the following benefits: • easier, safer and more cost-effective servicing • reliable trainstop operation in flood prone areas when the power unit is kept above the flood level Clearguard Circuit Controller Retrofit Kit Datasheet 6A-5 A replacement for drum-type circuit controllers with exposed contacts in older J-series trainstops. 7 SECTION 7 IS NOT IN USE. 8 SECTION 8 IS NOT IN USE. Short-Form Catalogue Issue 26.0 35 6 6 6.1 36 TRAINSTOPS Trainstops (Trip Type) © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 9 LEVEL CROSSING PROTECTION 9.1 Flashing Lights & Accessories 9. Level Crossing Protection 9.1 Flashing Lights & Accessories Wayguard Level Crossing Light Crossarms Datasheet 9A-2 • • • • • • • Proven functional and flexible design Minimised stock - just 4 kits cover every application Full adjustment for aiming lights All componenets powder coated black as standard Terminal box with 6 pairs M6 Studs as standard Supplied in easily manageable, un-assembled packs Suits 2 or 4 HC101L (210 mm) or HC300L (300 mm) crossing signals Sigmaguard LED Crossing Signals & Retrofit Kits Datasheet 9A-3 Complete signals and retrofit kits using LED technology: • complete signals—HC101L (210 mm) & HC300L (300 mm) • retrofit kits—available for most existing signals LEDs are high-safety, low-maintenance replacements for incandescent signals and lamps. They provide constant brightness over a wide voltage range and use about half the power of incandescent signals. 9 Sigmaguard LED Barrier Arm Lights Datasheet 9A-4 A fully-sealed light for installation on level crossing barrier arm. Each unit is supplied with a cable that connects to the barrier-mounted junction box, or as a combined double-sided light and junction box. The lights do not require voltage-setting resistors but will work with them in retrofit applications. Wayguard SAFEFLASH—Level Crossing Flasher Datasheet 9A-5 A safety-critical level crossing flasher meeting modern standards of safety, quality and reliability. Only one SAFEFLASH unit is typically needed to control the flashing lights of an entire crossing installation. The unit is self-contained and is designed to mount on Q relay style rails, a backboard or similar. It makes the replacement of existing flasher units as simple as possible. Short-Form Catalogue Issue 26.0 37 9 9.2 LEVEL CROSSING PROTECTION Barrier Mechanisms Wayguard SSCC III Plus—Solid-State Crossing Controller Datasheet 9A-6 A solid-state crossing controller that incorporates everything, other than train detection, that you need for a crossing control, in a single box. The SSCC III Plus directly interfaces with flashing lights, barriers, bells and track circuits—and you retain control over all settings. 9.2 Barrier Mechanisms Wayguard Circuit Controller and Motor Retrofit Kits Datasheet 9B-5 These retrofit kits are based on parts from the Style EB barrier mechanism. They contain modern circuit controllers and motor to extend the life of older style WRRS barrier mechanisms. Wayguard S-60 Level Crossing Barrier Mechanism Datasheet 9B-9 Ideal for operating crossing entrance and exit barriers for level crossing protection. Wide range of variants—including 12 and 24 Vdc input, entrance and exit gates—to cover all applications. The S-60 operates barrier arms up to 12 metres in length. • Robust barrier arm mechanism • Proven reliability—based on S-20 and S-40 predecessors • Power up, power down to 70° then gravity descent in a controlled manner • Maintenance switch to drive mechanism down when arm is knocked off • Suits aluminium, aluminium-fibreglass, and timber barrier arms • LED diagnostics and overspeed protection to prevent damage after arm broken • Advanced gearmotor and electric brake combination • Intelligent auto-reset overload circuit protects motor and circuit board if obstruction stalls mechanism • Horizontal and vertical buffers adjusted externally • AREMA-compliant Wayguard S-20/S-40 to S-60 Retrofit Kit ...NEW Datasheet 9B-9 Cost competitive upgrade of an S-20 or S-40 barrier mechanism to S-60 functionality and features (see above). 38 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 9 LEVEL CROSSING PROTECTION 9.3 9.3 Barrier Barrier Wayguard Level Crossing Barrier Arms Datasheet 9C-2 Barrier arms for any situation: • all-aluminium, aluminium-fibreglass or all-fibreglass • lengths up to 12 metres (40 feet), longer by special design • telescoping design for maximum strength and minimum wind resistance • modular construction for easy assembly and replacement • red and white reflective finish on both sides • LED or incandescent arm lamps easily fitted, or arms supplied with lamps fitted • high-wind (eg 150 km⁄h) arms, masts, supports and fittings available • optional insulated tips • AREMA-compliant Wayguard Pre-Dressed Level Crossing Barrier Arms ...NEW Datasheet 9C-4 Barrier arms: • ready to install at the required length • pre-fitted with low maintenance LED lights (to AS1742.7 or as required) and markings • wiring with plug-in design • all-aluminium, aluminium-fibreglass, or all-fibreglass; includes highwind resistant variants • lengths up to 12.7 m 9.4 Warning Bells Wayguard Level Crossing Bell—Solid State Datasheet 9D-4 This solid-state bell sounds exactly like a “real” bell, yet has no mechanical parts to break or wear out. It cannot be affected by dirt, water or wear, and never requires adjustment. The bell fully integrates with SEAR II crossing monitors for direct reporting of bell energisation and sound level (using an inbuilt microphone) over the bell control wires. Short-Form Catalogue Issue 26.0 39 9 9 9.5 LEVEL CROSSING PROTECTION Grade Crossing Predictors 9.5 Grade Crossing Predictors Wayguard Grade Crossing Predictors—4000 Series (GCP 4000) Datasheet 9G-3 Complete crossing control solution in one box—just add power. • slash design, installation and commissioning costs • control complex, multiple (1–5) independent crossings from one unit • simple configuration using pre-defined templates • integrated flasher, bell and barrier control optional SEAR IIi event recorder • three models: Basic GCP (single track), Basic Crossing (single track, controller and user interface), Multiple-Track Crossing (1–5 independent tracks, controller, user interface and SEAR IIi) See also “Wayguard Accessories—Grade Crossing Predictors” on page 41. Replaces 3000 Series GCPs. Wayguard Motion Sensor 4000 (MS 4000) ...NEW Reliably detect the motion of an approaching train and start the crossing warning system. • Configurable as a basic motion sensor type or grade crossing predictor type controller • Available as a redundant or non-redundant, single track controller. • Uses proven GCP 4000 modules • Simple user interface to easily program and set up the unit • Provides diagnostic history & train move history logs; can interface to a SEAR II Recorder/Analyzer for additional recording capability. 40 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 9 LEVEL CROSSING PROTECTION 9.5 Grade Crossing Predictors Wayguard Accessories—Grade Crossing Predictors Datasheet 9G-4 Accessories and replacement parts for the 3000 and 4000 Series GCPs: • narrowband shunts—single-frequency, multi-frequency and lowloading) • wideband shunt • bidirectional simulation couplers • simulated track inductors—fixed and adjustable • battery chokes (blocking reactors) • tunable IRJ bypass couplers • surge panels Wayguard DC Shunting Enhancer Panel Datasheet 9G-7 A very cost-effective solution for improving shunting in areas where marginal shunting is a problem. The unit applies a nominal 6 Vdc to the track at the crossing to break down the oxide film on the rails. Suits 3000 and 4000 Series GCPs. Short-Form Catalogue Issue 26.0 41 9 9 9.6 LEVEL CROSSING PROTECTION Installations Wayguard PSO GCP 4000 Datasheet 9G-8 A complete level crossing solution in one box for use where GCPs are not appropriate. Adds PSO 4000 track circuits to the proven crossing control of GCP4000. • slashes design, installation and commissioning costs • integrates multiple PSO tracks and island tracks with crossing control and diagnostics • integrated flasher, bell and barrier control plus optional SEAR IIi event analyser • powerful logic to interface with signalling system • suits electrified and non electrified railways • integrated stick logic and release timers 9.6 Installations Crossing in a Box Datasheet 9H-1 Pre-wired, pre-tested, comprehensive kit of parts and installation locations, standardised to local Rail requirements. Packed into lockable container so they can be removed in order of installation. Radically cuts time on site to install and test crossing and delivers lower total installed costs. 42 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 10 CONTROL AND SIGNALLING SYSTEMS 10.1 Computer-Based Interlockings 10. Control and Signalling Systems 10.1 Computer-Based Interlockings Interlocking Systems Datasheet 10A-33 Design optimum interlocking system from inter-operational WESTLOCK and WESTRACE Components. Use WESTLOCK with SSI style data and WESTRACE with ladder logic data or combine the two. • Integrated family of interlockings • Very high data capacity eliminates cross boundary data • Fast response times • Suits both distributed and centralised architectures • High availability just where you need it • ERTMS & ETCS compatible • Industry-standard communication • Design and service tools slash costs • Hot-swap maintanable • No fleeting outputs • SSI or ladder logic • Re-use current interlocking data WESTRACE interlockings Trackguard WESTRACE MkII Interlockings Datasheet 10A-38 WESTRACE MkII Interlockings cut your whole of life interlocking cost. Utilising the logic and safety proven in earlier WESTRACE interlockings and adds • Very high data capacity (all vital and non vital data processed together, vitally in one cycle) • Response times as fast as relay interlockings • Flexible architecture—distributed, centralised or combined • High availability where required • Hot swap any module without configuration • No fleeting outputs • Re-use interlocking data • Industry standard communications WESTRACE object controllers Trackguard WESTRACE Object Controllers Datasheet 10A-32 Use WESTRACE’s new modular Object Controllers to distribute input and output control to minimise signalling wiring: • works with both WESTRACE and WESTLOCK interlockings • Maintainer-resistant enclosed modules • hot-swap modules don't need configuring for replacement • connected via Ethernet or direct optical fibre Short-Form Catalogue Issue 26.0 43 10 10 10.1 CONTROL AND SIGNALLING SYSTEMS Computer-Based Interlockings Trackguard WESTRACE GCSS Datasheet 10A-3 A PC-based tool with an easy-to-use graphical interface that makes designing and configuring WESTRACE and iViu interlockings a simple and efficient task. Trackguard WESTRACE GSIM Datasheet 10A-4 A PC-based simulator for WESTRACE Interlockings. Simulate multiple WESTRACEs simultaneously, as well as interface to MoviolaW and WESTCAD. Controlguide MoviolaW Datasheet 10A-31 A PC-based graphic display and recording, logging and replay tool that supports WESTRACE, SSI and relay interlockings (via WESTRONIC S2). Users can see, in real time, the state of one or more interlockings and object controllers on a familiar mimic panel screen. MoviolaW displays track circuits, points, signals and other equipment for easy understanding of the their status. • Easy-to-read system fault messages • High capacity logging of all system events • Graphical replay of logged data • Remote access via modem or WAN • User-configurable event counting and reporting • Capable of displaying multiple interlockings on a single interface • User-configurable track layouts with the optional PC Graphics Editor (PCGE) Trackguard WESTLOCK Datasheet 10A-9 A 4th generation computer-based interlocking that is the natural successor to SSI that does not expose rail infra-structure owners to unnecessary write-offs with existing SSI assets. WESTLOCK features: • central interlocking processors—execute dual diverse logic using triple modular redundant hardware architecture and dual diverse software • trackside modules—provide the interface between the Central Interlocking Processors and the trackside equipment • configuration tools—based on NT, these tools configure WESTLOCK installations and enable operation simulations • diagnostic tools—including technician’s workstation, remote diagnostics, event recording and playback 44 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 10 CONTROL AND SIGNALLING SYSTEMS 10.2 Telemetry Systems Trackguard Solid-State Interlocking (SSI) Datasheets 10A-11 to 10A-28 A complete range of components for the British Solid-State Interlocking. Use WESTLOCK or WESTRACE for all new installations Vital Signal Logic Simulator (VSLS) Datasheet 10A-34 A powerful and efficient tool for checking interlocking logic designs. A click of the mouse toggles the state of any input, and the resulting changes in signal aspects and other outputs are easily observed. • Office-test complete interlocking systems • Test systems of multiple connected interlockings and communications • Simultaneously test vital and non-vital logic • Supports most interlocking systems, eg MicroLok, Microtrax, VHLC, VPI, Relay • Automate repetitive testing with easily-recordable scripts • Prepare field test lists • Useful training tool • Runs on Windows XP with multiple monitors 10.2 Telemetry Systems Controlguide WESTRONIC S2 (System Two) Datasheet 10B-3 Powerful SCADA applications with the additional benefits of localised and distributed processor capabilities. A range of specialised I/O modules provide an interface to the target application while a similar range of bearer interface modules communication with the transmission medium. Controlguide WESTRONIC S2 Telemetry Scanner Modules S2/SCN41 Enhanced scanner module Datasheet 10B-4 S2/SCN42 Standard scanner module Short-Form Catalogue Issue 26.0 The S2 Scanner Module forms the controlling element of the WESTRONIC S2 subsystem by controlling all of the input and output modules. Two models: S2/SCN41 (enhanced), S2/SCN42 (standard) 45 10 10 10.2 CONTROL AND SIGNALLING SYSTEMS Telemetry Systems Controlguide S2/DIP42 Digital Input Module Datasheet 10B-5 This module interfaces with the S2 Telemetry Scanner Modules to provide 32 digital inputs to the WESTRONIC S2. Inputs are filtered and buffered by logic gates to prevent corruption by electrical noise. Input is active low. Controlguide S2/DIP43 Digital Input Module Datasheet 10B-6 This module interfaces with the S2 Telemetry Scanner Modules to provide 32 digital inputs to the WESTRONIC S2. Inputs are filtered and buffered by logic gates to prevent corruption by electrical noise. Input is active high. Controlguide S2/DOP42 Digital Output Module Datasheet 10B-7 This module interfaces with the S2 Telemetry Scanner Modules to provide 32 digital outputs from the WESTRONIC S2 capable of driving external relays referenced to supply. Controlguide S2/DOP43 Digital Output Module Datasheet 10B-8 This module interfaces with the S2 Telemetry Scanner Modules to provide 32 digital outputs from the WESTRONIC S2 capable of driving external relays referenced to ground. Controlguide S2/ALC Alarm & Line Changeover Datasheet 10B-9 Provides ancillary functions to the WESTRONIC S2 telemetry system including power failure, bearer failure or user defined alarm functions. It can also provide attenuator switching, telemetry force off, and a selection of manual or automatic line/bearer changeover/hunting functions. Controlguide WESTRONIC S2/PSU Power Supply Module Datasheet 10B-10 These modules provide simple plug-in performance for most of the most of the standard supply voltages used throughout the railway industry. Controlguide S2/SLC Serial Line Converter (RS232-RS422) Datasheet 10B-14 Provides level conversion between RS232 and RS422 interface standards, 8 channels in each direction with an option of 16 channels. 46 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 10 CONTROL AND SIGNALLING SYSTEMS 10.2 Telemetry Systems Controlguide S2/VFC45 Voice Frequency Modem CCITT V.23 FSK Datasheet 10B-21 Operates over a voice frequency channel (300–3400 Hz) at 1200 bps full duplex on 4 wire operation. Can be used in point-to-point or multi-drop configurations. A front mounted serial (RS232c) port is available for external user requirements. Vital and Non-Vital Communication Systems Datasheet 10B-27 Wayside communication without cable costs is explained in this datasheet. It shows how Echelon, Ethernet and serial networks can be integrated along a railway using LIPD class licence spread-spectrum radio, media bridging and intelligent routing. See also: • Datasheet 10B-15—HD/Link • Datasheet 10B-24—Ethernet Spread-Spectrum Radio • Datasheet 10B-26—Wayside Access Gateway (WAG) HD/Link System Datasheets 10B-15 and 10B-27 A vital telemetry system that can operate over a local network, use spread spectrum radio or other bearers. Ideal for pole line replacement, cable elimination, or vital timer applications. Ethernet Spread-Spectrum Radio (ESSR) Datasheets 10B-24 and 10B-27 An Ethernet-enabled spread-spectrum radio with versions for operating under a no-fee class licence in the 900 MHz and 2.4 GHz ISM (industrial, scientific and medical) bands. Establish point-to-point, point-to-multipoint and linear networks without the expense and time of installing cable. Use with HD/Link, or as part of vital and non-vital telemetry. Wayside Access Gateway (WAG) Datasheets 10B-26 and 10B-27 The WAG is an intelligent media converter that bridges communication between Echelon, Ethernet and serial network technologies. It connects directly to the Ethernet Spread-Spectrum Radio (datasheet 10B-24) to link where no other communication exists. Short-Form Catalogue Issue 26.0 47 10 10 10.3 CONTROL AND SIGNALLING SYSTEMS Train Control Equipment CNA2000 Network Adapter Datasheet 10B-30 • • • • • • Interfaces Siemens and third-party signalling and control systems Interfaces serial and packet-switched communications Provides IP access to remote field equipment Communicates over public and private networks Supports ATCS addressing Other custom protocols can be supported 10.3 Train Control Equipment Train Graph Controlguide Rail 9000 Main Rail 9000 Signaller’s GUI ARS Operator’s Interface (AOI) Datasheet 10C-7 Rail 9000 is a single Control Centre that consists of a set of central servers and multiple Signaller workstations (clients). Each Signaller: • can always see all of the railway; • can control any number of zones within the railway • can assign, remove or query zones Signallers use Rail 9000’s mouse or keyboard to create and send commands to interlockings, and receive feedback from the interlocking on their multimonitor display. Controlguide WESTCAD Datasheet 10C-2 A PC-based control and display system that provides a flexible, costeffective alternative to hard-wired panels. Supports multiple monitors and can control most local and remote interlockings. 10.4 Automatic Train Control and Protection Trainguard WESTECT II ATP (Automatic Train Protection) ...Improved Datasheet 10F-2 A continuous radio-based ATP system that ensures trains: • cannot move without the interlocking’s authority • cannot exceed speed limits • cannot pass signals at stop • cannot roll away accidentally Shunting trains are limited to safe speeds and distances. Speed and performance are not sacrificed to achieve these benefits. 48 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 10 10.4 Trainguard ETCS CONTROL AND SIGNALLING SYSTEMS Automatic Train Control and Protection ...NEW Datasheet A19100-V100-B875-V3-7600 ETCS is the basis for interoperability between on-board and trackside equipment from any supplier. Provides signal aspect and line profile, including line speed & speed restrictions, to the driver; on-board system applies brakes, if necessary. Siemens provides a complete, integrated portfolio of products conforming to ETCS specifications, including: • ETCS Level 1 • Trainguard 100 on-board equipment for ETCS Level 1 • Trainguard Eurobalise S21 and S22 for track to train communications • Trainguard Lineside Electronics Unit (LEU)S2 to link signals with Euroblaises and Euroloop • Trainguard Euroloop S21 F to complement Eurobalises for shorter headways • Trainguard Basic Indusi for migrating Indusi/PZB 90 into ETCS • ETCS Level 2 • Trainguard 200 on-board equipment for ETCS Level 2 • Trainguard Radio Block Centre Control Centre iVIU trackside Vital Interface Unit Trackguard Train Sentinel Datasheet 10A-36 iVIU Universal Track Module Train Sentinel onboard display and control Move beyond paper-based train order and track warrant systems with Train Sentinel delivering non-conflicting electronic train orders with protection against exceeding these authorities. • Faster, more efficient and safer than manual systems • Mimic and train graph based authority generation • Points controlled, locked and detected via data circuits • Authority exchange via data radio (with optional voice confirmation) • Driver has written and graphical authority • Prevents exceeding movement and speed authority • Automated authority rollup after train • Easy and small to retrofit • Retrofit to dark and CTC territory 10 End of Train Devices Datasheet 10F-6 The Siemens series of End-of-Train (EOT) devices includes a standard EOT and a mobile modem equipped EOT for remote tracking. Both styles share the following features: • High strength, polymer enclosure • Enclosed antennas & AEI tag • Positive, horizontal 4 hole mounting mechanism • Battery charging air generator • External battery charging port • Internal event recorder • High visibility marker • GPS receiver • 8 character display Short-Form Catalogue Issue 26.0 49 10 10.5 CONTROL AND SIGNALLING SYSTEMS Automatic Equipment Identification (AEI) Systems Head of Train Devices Datasheet 10F-7 Train complete detection cab equipment for use with Siemens and Industry standard End of Train Device. Communicates with End of Train to determine: • Train complete • Motion Detector • Brake pip pressure • Battery status • Optionally, apply emergency brake 10.5 Automatic Equipment Identification (AEI) Systems Transcore Automatic Equipment Identification Datasheet 10G-1 A fast, accurate and reliable means of identifying containers or rolling stock whether stationary or moving at speeds up to 300 km/h. Trackguard WESTECT Portable Transponder Reader Module (PTRM) Datasheet 10G-26 • • • • • Lightweight ergonomic design for easy, comfortable tag reading Use in harsh operating environments Displays tag data on sunlight readable screen Logs WESTECT reads for later download via USB or ethernet Versions for standard transportation and WESTECT tags Transcore AI1200 Reader Datasheet 10G-4 Provides an operational link between tagged objects and the host information management systems. Transcore AR2200 RF Module Datasheet 10G-5 This is a dual output radio transmitter-receiver controlled by a Transcore reader (eg AI1200). Upon command from the reader, the module generates and broadcasts an RF signal from one or two antennas. It then receives, demodulates, amplifies and conditions the signal reflected from a tag and delivers it to the reader. 50 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 10 10.5 CONTROL AND SIGNALLING SYSTEMS Automatic Equipment Identification (AEI) Systems Transcore Encompass 4 RFID Tag Reader Datasheet 10G-6 This is an antenna, radio frequency module, tag decoder, and power supply in one integrated package. New low power model does not require a separate ACMA licence. Transcore AA3233-004 Heavy Rail Antenna Datasheet 10G-22 A rugged 915 MHz antenna specifically designed for mounting between track rails: • constructed for high shock and vibration environments • rugged weatherproof enclosure that provides protection from harsh environmental conditions encountered on railroad tracks • dimensions compatible with mounting under the locomotive Transcore AA3234 Light Rail Antenna Datasheet 10G-21 Designed specifically for light rail applications requiring a low profile, such as the undercarriage of commuter trains and people mover systems: • constructed for high shock and vibration environments • rugged weatherproof enclosure • dimensions compatible with mounting underneath trains Transcore AA3110 Parapanel Antenna Datasheet 10G-7a Used to broadcast and receive radio frequency signals in the 902 to 928 MHz RF band. 10 Short-Form Catalogue Issue 26.0 51 10 10.5 CONTROL AND SIGNALLING SYSTEMS Automatic Equipment Identification (AEI) Systems Transcore AT5118 Rail Harsh Environment Rail Tag Datasheet 10G-25 Beam-powered general use Rail Tag, ideal for mounting on railcars, vehicle chassis or inter-modal containers. • harsh-environment durability • factory-sealed case • factory-programmed or field-programmable • 1088-bit data storage • data encryption and authentication • fully compliant with Association of American Railroads (AAR), American Trucking Association (ATA) and TransCore Super eGo®(SeGo) protocols Transcore AT5413 Hardened Rail Tag Datasheet 10G-28 Beam-powered hardened Rail Tag ideal for mounting on sleepers. Use for WESTECT ATP. • harsh-environment durability • factory-sealed case • factory-programmed or field-programmable • 1088-bit data storage • data encryption and authentication • fully compliant with Association of American Railroads (AAR), American Trucking Association (ATA) and TransCore Super eGo®(SeGo) protocols Transcore PT5780 Permissions Tag Datasheet 10G-24 Used to configure the AP4118 Rail Tag Programmer. • secure tag data can be used by AP4118 Rail Tag Programmer only • can be used once or multiple times where scheduled reconfigurations are required • factory programmed to specific customer requirements • uses Super eGo® (SeGo) operation mode • factory-sealed case Transcore AT5720 Check Tag Datasheet 10G-10 Provides a means for performing end-to-end status checks of Transcore systems. 52 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 10 CONTROL AND SIGNALLING SYSTEMS 10.6 Fault Monitoring and Data Logging Transcore AP4118 Rail Tag Programmer Datasheet 10G-23 Used to program AT5118 Rail Tags, which use Super eGo® protocol. Programming occurs via a radio frequency (RF) signal. Tag programmer functions include programming permissible tag data pages and interrogating permissible data pages. Tag data pages can be easily programmed. 10.6 Fault Monitoring and Data Logging Wayguard SEAR II Event Analyser and Recorder Datasheet 10H-3 The second generation Safetran Event Analyser and Recorder. SEAR II is a non-vital stand-alone system designed to provide continuous real-time general purpose status monitoring and event recording for a wide range of functions associated with a crossing, interlocking, or similar installation. Wayguard SEAR II Accessories Datasheet 10H-4 These accessories extend SEAR II crossing monitoring for comprehensive detection of flashing light, bell or barrier arm failures. Axle Counter SEAR Island Interface (ACSI) Datasheet 10H-7 10 Pseudo Island for connecting Frauscher Axle Counters to SEAR • Allows SEAR to monitor crossing warning time • Simple island simulator • Plug connection to axle counter • No axle counter modification required • Uses standard SEAR application Wayguard Argus Event Recorder Datasheet 10H-5 A compact, inexpensive, non-vital stand-alone unit for conventional level crossings. Argus monitors and logs railway events, generates alarms based on sitespecific criteria, and produces reports. USB port for transfer of software, logs and reports via memory stick • Ethernet port for logging and Telnet Short-Form Catalogue Issue 26.0 53 10 CONTROL AND SIGNALLING SYSTEMS 10.7 Integrated Communication and Control Systems (ICSS) Condition Monitoring Datasheet 10H-6 Strukton’s POSS condition monitoring system widely used throughout Europe is now available from and supported by Siemens • • • • • • • • Monitors points, tracks, axle counters and crossings Reduce train delays due to points failure by 25% to 50% Immediate advice of failures Identify degradation before it leads to failures Identify most likely problem before attending site Improve maintenance planning with operational statistics Improve training based on degradation and failure statistics 24 * 7 monitoring and access from anywhere via web browser 10.7 Integrated Communication and Control Systems (ICSS) Controlguide SystematICS Integrated Railway Management Solutions Datasheet 10I-1 ... Train Describer Voice FIRE Control TRACTION ELECTRICAL MECHANICAL SECURITY RailSCADA SystematICS Platform Improve efficiency, reduce costs and enhance operational capability. SystematICS is a high-performance, scalable, open control systems product that provides the core platform for a wide range of applications for the rail control environment. Also see Controlguide SystematICS RailSCADA. Controlguide SystematICS RailSCADA Intelligent Rail Management Applications Datasheet 10I-2 Use SCADA telemetry and data processing for: • complete station management (including security and fire management) • electrical and mechanical plant management • traction power management • environmental management 54 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 11 11.1 ACCESSORIES Terminal Blocks 11. Accessories 11.1 Terminal Blocks RSA Double-Row Terminal Blocks Datasheet 11A-1 A range of M5 and M6 terminal blocks (complete with nuts and washers), shorting links and insulating links. Available from 1 to 6 way (2 to 12 studs). 11.2 Lightning and Surge Arresters Surge Arresters Datasheet 11D-1 Every WESTRACE input and output connected external to the SER or location case should be protected from the impact of transient voltages. These WESTRACE specific surge arresters protect against common or differential mode transients. • Fulfils WESTRACE Safety Requirements • 50 Vdc and 110 Vac inputs • Repeatable protection up to 10 kA • Complies with relevant functional and safety standards • Visual indication of input or output state via LED • Visual indication of unit health via LED when ON • Separate base and surge protection module; colour coded base to prevent incorrect module insertion • Available for 35 mm “T” or 32 mm “G” DIN rail • Earth connection via rail or separate terminals • Isolates WESTRACE on excessive fault current Short-Form Catalogue Issue 26.0 55 11 11 11.2 ACCESSORIES Lightning and Surge Arresters Track Circuit Surge Arresters Datasheet 11D-2 Minimise damage to track circuits with this robust surge protection device that protects equipment from high voltage, high energy transients. One compact unit with: • Line – Line (differential mode—equaliser) • Line – Earth (common mode—arrester) Benefits: • Use in electrified or non-electrified territory • Suit dc, ac, jointless, overlay, predictor tracks and most other units • Automatic reset once disturbance past • Minimise costly down time Surge Reduction Filter (SRF) Datasheet 11D-3 The SRF combines high energy surge protection and electrical noise reduction in a compact unit for new generation axle counter counting head cables. Optimised for use on the Siemens Clearguard ACM family of axle counters. Air Gap Arresters Datasheet Sh-01-01 Four types that meet or exceed all applicable AREMA specifications. Fourpart datasheet describing: • Clearview—air gap type with 16 discharge point electrodes designed for use on low voltage signal circuits and 115 Vac power circuits • Heavy Duty Clearview—air gap type with 16 discharge point electrodes; has a higher surge current capability than the Clearview • Heavy Duty—full air gap type for use on track circuits or where extremely high surge currents are experienced • Clear-Comm—air gap type with 16 discharge point electrodes designed for use on communication circuits Available with protective caps and on porcelain bases with terminal studs. Clear-Comm Lightning Arresters Datasheet Sh-01-05 See datasheet for ordering information. 56 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 11 ACCESSORIES 11.3 Resistors Heavy Duty Equalisers Datasheet Sh-02-01 A closed circuit shunt type protector for use on up to 24 Vdc circuits. Maintains its 1000 minimum resistance and rated breakdown voltage over a long service life. A sealed version is available for use on equipment subject to moisture or immersion. Although surge handling capability is not as great as the Heavy Duty Equaliser, resistance remains constant in the presence of moisture. 11.3 Resistors Sealed Resistors Datasheet Sj-01-01 Made with alloy resistance wire wound on a porcelain core to which stainless steel lugs are attached. The assembly is embedded in insulating ceramic cement and a steel casing which is sealed with a high grade insulating paint. Can be used as heating units within some equipment to prevent frost accumulation at vital points such as commutators to contacts. All units are 100% tested for resistance and each unit is guaranteed to have a nominal value not less than the rated value. Units are noted in AREMA wattage specified in Manual Part 135. Maximum rise of hottest temperature part of resistor body is 147°C above ambient. Resistance Units—Adjustable, Fixed Datasheet Sj-02-01 These units provide a sliding contact with resistance gradations. All units are 100% tested for resistance and each unit is guaranteed to have a nominal value not less than the rated value. Units are noted in AREMA wattage specified in Manual Part 135. Maximum rise of hottest temperature part of resistor body is 55°C above ambient. 11.4 Tools Insulated Terminal Wrenches Datasheet 11F-1 For ¼ BSW, M6, 2 BA, M5 railways signal terminal nuts. Zinc plated steel body embedded in a moulded plastic handle. Short-Form Catalogue Issue 26.0 57 11 11 11.4 ACCESSORIES Tools Relay Tag Crimping Tool For crimping one or two wires into a Q crimp. Contact Removal Tool Barrier Mechanism Toolkit Datasheet 11F-4 A set of tools that simplify setting up models S, SM, S-20, S-40, S-60 and SMB barrier mechanisms using an easier method than the conventional spring scale for both horizontal and vertical torque measurements. Includes: • torque wrench • ratchet tools for manually raising the barrier • special hex key for adjusting the cams Track Circuit Short Finder ...Improved Datasheet 11F-5 Locate track circuit shorts quickly with this easy-to-use meter and purposedesigned probes. • Can also be used: • to locate high resistance bonds and track connections, noisy air gap arrestors etc • as an insulated joint tester • for local ballast condition measurements 12 58 SECTION 12 IS NOT IN USE. © Siemens Rail Automation Pty Ltd 2014. All rights reserved. 13 SERVICES 13.1 Training 13. Services 13.1 Training Railway Signalling Training Datasheet 13A-1 Use our Training Department for cost-effective professional training. Choose from over 120 courses to meet your organisation’s needs. 13.2 Technical Documentation Technical Documentation Services Reduce the potential for costly errors and increase your staff’s effectiveness—engage our rail-experienced technical documentation team to make your information more easily used. Choose from various formats, including: • flowcharts • work instructions • maintenance manuals • quick reference cards 13.3 Refurbishments and Design Q Relay Refurbishment Datasheet 13B-4 • Q relays restored to original specification for around 60% of the cost of a new relay • QA certificate supplied • Full 12-month warranty • Contacts, pivot plates and covers replaced to latest specification where necessary and compatible • Fast turnaround supports use for stageworks and spares • Most brands and models Short-Form Catalogue Issue 26.0 59 13 13 13.3 SERVICES Refurbishments and Design Electro-mechanical Refurbishment Datasheet 13B-1 Return your worn-out equipment to Invensys Rail for partial or complete refurbishment. Point Layouts Datasheet 13B-3 We have over 250 standard, proven and approved designs on file for just about every point machine whether pneumatic, hydraulic or electromechanical—and every point layout. We have design approval with all major Australian and some overseas Railways. Standard designs are all field proven. So chances are we have your solution already. Save valuable time and reduce risks by using installation kits from the point experts. One order provides everything needed for an installation so you don’t have to manage design, ordering, order chasing, kitting etc. 60 © Siemens Rail Automation Pty Ltd 2014. All rights reserved. Siemens Rail Automation Pty Ltd ABN 78 000 102 483 380 Docklands Drive Docklands Victoria 3008 Australia T F E W +61 1300 724 518 +61 3 9616 9001 [email protected] http://www.siemens.com.au/rail-components