ChangeLog Version 9.2.7

Transcription

ChangeLog Version 9.2.7
ChangeLog
Version 9.2.7
CFturbo® Software & Engineering GmbH ▪ www.cfturbo.com
ID
5011
5028
5051
5067
Severity
major
crash
minor
minor
Category
Volute cutwater
Functions
Volute diffuser
Main dimensions impeller
Summary
Simple cutwater fails for a double volute sample
Functions dialog sometimes crashed while closing
One curve of diffuser reference geometry is not visible
Wrong unit is displayed in information for turbines
5068
5072
5094
5097
5099
5101
5110
5111
5115
5119
5122
crash
minor
tweak
minor
major
minor
minor
feature
feature
crash
minor
Volute diffuser
Functions
Export
General
Finishing
Mean lines
General
Performance prediction
Batch mode
3D graphic
Main dimensions impeller
Last spiral section is incorrect for certain volutes depending on diffuser configuration.
Selecting a wastewater function fails for impellers without defined blade properties
3D-Update done when export base file name edited
Wrong calculation of meridional cross section area
Removing the blades of a bladed stator leads to exceptions
Wrong warning about overlapping blades appears for single bladed impeller
Access denied exception when saving CFturbo project
Mass flow is missing as another option for the performance prediction of compressors and pumps
Add extension handler for batch file
Exception in the Intel OpenGl graphics driver can occur when closing a project
Machine Mach-Number not correctly calculated
5125
5126
5128
5129
tweak
major
minor
minor
3D graphic
Mean lines
Volute cutwater
Main dimensions impeller
Progression dialog stays invisible if view is switched from 3D Model to Meridian and back
Comparing impellers with and without splitters causes problems
Creation of solid failed for a volute with simple cutwater due to tolerances between spiral and cutwater
Shaft diameter calculation sometimes not updated
3D graphic
Export
Impellers are not rotating because the initial speed is 0
ANSYS TurboGrid: Diamonds are located on arbitrary places of meridional contour
5132 tweak
5176 minor
5170 major
Export
5165
5158
5142
5120
5115
5103
Licensing
Export
Export ICEM
Export
Batch mode
Export
minor
minor
minor
minor
feature
tweak
ANSYS TurboGrid: Required splitter position rel. to main blade has to be considered when rotation is "counter
clockwise"
Virtual Machine VPC not detected
ANSYS BladeGen: overlapping of shroud and last blade curves for open impellers
ANSYS ICEM-CFD: Show warning on export dialog for internal volutes
Trailing edge description missing in cft-geo file
Add extension handler for batch file
There is an unfitting warning in batch mode when exporting into 3D model based formats