Tender Civil Electrical and Services BOQ
Transcription
Tender Civil Electrical and Services BOQ
S.N. 1 2 3 4 5 6 ABSTRACT SHEET DETAIL DISMANTALING WORK NEW CIVIL AND FINISHING WORK TOILET PASSAGE & OTHERS SERVICES ELECTRICAL TOTAL IN FIGURES : AMOUNT IN Rs. TOTAL IN WORDS : 1 Demolition work S.N. DESCRIPTION OF ITEM UNIT QTY. SCHEDULED ITEM DISMANTLING WORK 1 2 3 4 5 6 7 8 9 1 2 Demolishing brick work, manually/ by mechanical means including stacking of serviceable material and Cum disposal of unserviceable material within Campus as per direction of Engineer-in-charge. In Cement mortar Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within campus Dismantling tile work in floors and roofs laid in cement mortar including stacking material within campus. thickness of tiles above 25 mm and upto 40 mm Demolishing R.C.C. work, including stacking of steel bars and disposal of unserviceable material within campus as per direction of Engineer - in- charge. Extra for scrapping, cleaning and straightening reinforcement from R.C.C. Work. Dismentling of wall tile laid in cement mortar and disposal of unserviceable material within campus Dismantling G.I. water pipe with fittings and clamps including stacking the material within campus Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within campus Electrical conduits and wires TOTAL SCHEDULED ITEM Sqmt 746 Sqmt 643 Cum 11 KG Sqmt 170 70 Rmt Rmt 226 94 Rmt 240 NON SCHEDULE ITEM Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, Sqmt architrave, holdfasts etc. complete and stacking within campus Dismantling aluminium doors, windows and shutter including chowkhats, architrave, holdfasts etc. complete Sqmt and stacking within campus.(Equipment room) TOTAL SCHEDULED ITEM GRAND TOTAL 2 102 108 4 RATE AMOUNT NEW CIVIL WORK S.N. DESCRIPTION OF ITEM UNIT QTY. Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within th campus) All kinds of soil. Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level: 1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) Filling-: Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in : 1:6 ( 1 cement: 6 course sand) Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level in 1:4( 1 cement : 4 course sand) Extra for providing and placing in position 2 Nos. 6mm dia. M.S.bars at every third course of half brick masonry (with F.P.S.bricks). 12 mm cement plaster of mix : 1: 6 (1 cement: 6 fine sand) FINISHES Providing and laying Vitrified tiles in floor of size 600X600mm of thikness 8mm, with water absorption less than 0.08% and conforming to IS:15622 , of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6mm thickness, including grouting of joints with white cement &matching pigments etc. complete.. Basic cost of tile Rs.60/- per sqft Cum 140 Cum 32 Cum 8 Cum 68 Cum 90 Sqmt 145 rmt 145 Sqmt 1100 Sqmt 607 NEW CIVIL WORK 1 2 3 6 7 8 8.a 9 10 3 RATE AMOUNT S.N. 11 12 DESCRIPTION OF ITEM UNIT Providing and laying Vitrified tiles of size 600X600mm of thikness 8mm, with water absorption less than Sqmt 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Basic cost of tile Rs.60/- per sqft Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by Sqmt QTY. 157 96 the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including 13 14 15 16 17 18 pointing in white cement mixed with pigment of matching shade complete. Basic Cost of tile Rs.45/- per sqft Kota stone slab flooring and skirting over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 18mm thick kota stone Providing and fixing chowkhats of doors, windows, clerestory windows and other frames , wrought framed and fixed in position in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), including painting two coats of enamel paint on sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within the campus.(Seasoned Second Class Teak wood) Section 150x 50 mm Extra for providing lipping with 2nd class teak wood battens on all edges of shutters (over all area of door shutter to be measured) PAINTING Applying one coat of cement primer of approved brand and manufacture on wall surface, cement primer Sqmt 102 Cum 12 Sqmt 260 Sqmt 2400 Providing and applying birla putty of 2 mm thickness over plastered surface to prepare the surface even and Sqmt smooth complete Wall painting with plastic emultion paint of approved and manufacture to give an even shade, two or more Sqmt coats on new work TOTAL SCHEDULED ITEM 2400 4 2400 RATE AMOUNT S.N. 19 19a 19b 20 DESCRIPTION OF ITEM UNIT NON SCHEDULE ITEM Providing and fixings and stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : 12.23.1 Red sand stone slab Iincluding fixing of steel girders and members and rebaring with exisiting structure wherever necessary 35 to 40 mm thick Sqmt Structural steel section: Steel work welded in built up sections work, including cutting , hoisting, fixing in KG position and aplying priming coat of approved steel primer using structural steel etc, in stringres, treads, landings etc of staircases , all complete Grid Ceiling:-Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with DUNE/TEGULAR EDGE TILES WITH ARMSTRONG GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC Upto 0.5, Light Reflectance >85%, Thermal Conductivity k = 0.052- 0.057 w/m K, Colour White, Fire Performance Class 0/ Class 1 (BS476 Part 6&7) in module size of 600 X 600 X 16 mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 63%. The tile shall be laid on Armstrong grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68 Kgs/M2. Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 120 grams per M2 & passed through 500 hrs of Salt test. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre & not more than 150mm from spliced joints. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 600mm from the adjacent wall. 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm modules to be formed by fitting 600mm long cross tees centrally between the 1200 mm cross tees. The 1200mm cross tees to have central “birdsmouth” notches to facilitate fitting of 600mm cross tees. Perimeter trim to be Armstrong shadow wall molding (dimensions: 19x7x7x14mm), secured to walls at 450 mm maximum centres. 5 QTY. 32 1800 RATE AMOUNT S.N. DESCRIPTION OF ITEM UNIT ARMSTRONG SUSPENSION SYSTEM accessories manufactured and supplied by Armstrong World Industries Sqmt QTY. 114 consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanised steel of size 26 x 26 x 25 x 1.2mm with a Galvanised Thickness of 80gsm, A pre Straightened Hanger wire of dia – 2.68 mm of 1.83 m length., thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8mm thick, galvanised spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable 21 22 23 24 25 26 27 28 clip also consists of a 3.5 mm aquiline wire to be used with the main runner. Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of Sqmt block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters , 35 mm th including P/F of 1 mm th laminate on both faces, P/f ISI marked stainless steel butt hinges with necessary screws Extra for providing vision panel in all type of flush doors (cost of glass included) including cost of lipping , Nos complete in all respects ( less than 0.1 sqmt) 750x550mm Providing and fixing chromium plated SS 100 mm mortice handle with lock set and key with necessary Sets screws etc. complete. Doorset or approved equivalent make Providing and fixing S.S. tower bolts with necessary screws etc.complete : 200 mm long Nos Providing and fixing S.S. hanging floor door stopper required colour and shade with necessary screws etc. Nos complete. Providing and fixing ISI marked aluminium die cast body tubular type univesal hydrolic door closers with Nos necessary accessories and screws etc. complete Providing and fixing 6 mm th toughned glass fixed with 50mmx 50mm 16 guage aluminium frame duly Sqmt powder coated including all gasced, beeding and other accessaries , complete as per architectural drawing Providing and applying two or more coats of anti fungal paint including making of proper base and one base Sqmt coat of anti fungal primer, complete in all respects. 6 116 12 34 68 34 20 8 135 RATE AMOUNT S.N. 29 30 DESCRIPTION OF ITEM UNIT Providing and fixing powder coated (minimum thickness of powder coating 50 micron)aluminium work Sqmt 50mm x 50mm 16 gauge for doors, windows and ventilators with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt /silicon etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete including handles , friction hinges , stays etc. complete including filling silicon all around of frame & wall joints as per architectural drawings and the directions of Engineer-in-charge. (Rates are inclusive of providing and fixing 5mm thick float glass for fixed portion and 5mm thick float glass for openable portion Repairing, removing rust, fixing damaged/missing hardware and painting with enamel of existing MS Sqmt window frames and windows of the front façade from inside and outside. (As per site requirement) TOTAL SCHEDULED ITEM GRAND TOTAL 7 QTY. 30 85 RATE AMOUNT TOILETS S.N. 1 DESCRIPTION OF ITEM UNIT QTY. Finishes Floor Tiles : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the Sqmt 20 manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting 2 the joints with white cement and matching pigments etc., complete. (Basic Cost of tile Rs.60/- per sqft) Wall tiles : Providing and laying Vitrified tiles of size 600X600mm of thikness 8mm, with water absorption Sqmt 89 less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint 3 4 5 9 with white cement & matching pigments etc. complete. (Basic cost of tile Rs.60/- per sqft) PAINTING Applying one coat of cement primer of approved brand and manufacture on wall surface, cement primer Sqmt 90 Providing and applying birla putty of 2 mm thickness over plastered surface to prepare the surface even and Sqmt smooth complete Wall painting with plastic emultion paint of approved and manufacture to give an even shade, two or more Sqmt coats on new work Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC 90 90 plain and brass threded fittings including fixing the pipes with clamps@ 1mt spacing . This includes jointing of pipes and fittings with one step CPVC solvant cement and the cost of cutting chases and making good the 10 11 12 13 same including testing of joints complete as per direction of engineer incharge. 15 mm nominal outer dia pipe 20 mm nominal outer dia pipe 25 mm nominal outer dia pipe Providing and fixing of square mouth SW gully trap grade A' complete with CI grating brick masonry chamber with water tight CI cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50kg and frame to be not less than 2.70kg as per standered design: 8 Rmt Rmt Rmt Nos 22 0 85 1 RATE AMOUNT S.N. 14 15 DESCRIPTION OF ITEM UNIT QTY. Providing and fixing water closet squatting pan ( indian type W.C. ) with 100mm pvc P or S trap, 10lt low level white pvc flushing cistern with manual controlled device confirming to IS : 7231 with all fittings and fixtures complete including cutting and making good the walls and floor wherever required Providing and fixing white vitrous china pedestal type water closet ( European type W.C. ) with seat and lid , Nos 2 Nos 1 Nos 3 Nos 4 Nos 4 Nos Nos Nos 6 2 4 10 lt low level white pvc flushing cistern with manual controlled device confirming to IS : 7231 with all 16 17 18 19 20 21 fittings and fixtures complete including cutting and making good the walls and floor wherever required Providing and fixing white vitrous china flat back half stall urinal of size 580 x 380 x 350 mm with white PVC automatic flushing cistern, with fittings , standard cp brass flush pipe spreaders with union and clamp( all in CP brass) with waste fitting as per IS 2556, pvc trap with outlet grating and other couplings in cp brass including painting of fittings and cutting and making good the walls and floor wherever required( single half staal urinal with 5 lt PVC automatic flushing cistern) Providing and fixing white vitrous wash basin with C.I. bracets, 15 mm cp brass pillar taps, 32 mm cp brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever required( basin size 630x450mm with single 15mm cp brass tap) Providing and fixing uplasticised PVC connection pipe with brass unions, 30 cm long, 15mm nominal bore Providing and fixing brass bib cock/angle valve of approved quality Providing and fixing of 600 mm long C. P. brass towel rail complete with C.P. brass brackets Providing and fixing CP Brass liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubbs centrally between the 1200 mm c 9 RATE AMOUNT S.N. 22 a 23 DESCRIPTION OF ITEM UNIT QTY. The Pipes will be supported with threaded G I rods & U clamps with nuts, washers etc on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating Rmt 22 Rmt Rmt 10 16 Nos Nos Nos 6 4 1 Nos 4 Nos 18 Nos 1 with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. 32 mm dia. 40 mm dia. 24 a b c 25 26 20 Providing & fixing UPVC Floor trap of self cleansing design with stainless steel grating complete in all respects. Multi Floor Trap (5" Ht) with height raiser and branch saddle strip of 50/75 mm outlet Plain Floor Trap (4" Ht) with 50 / 75 outlet and with height raiser P-Trap type Floor Trap 110 x 75 mm Providing and fixing C.P brass bib cock of approved quality conforming to IS standards IS: 8931. 15 mm nominal bore Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931. 15 mm nominal bore TOTAL SCHEDULED ITEM NON SCHEDULED ITEM Removal of toilet fittings and stacking the material within campus as directed by engineer incharge 10 RATE AMOUNT S.N. 21 22 23 24 DESCRIPTION OF ITEM UNIT QTY. Providing and fixing powder coated (minimum thickness of powder coating 50 micron)aluminium work for sqmt windows and ventilators with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt /silicon etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete including handles , friction hinges , stays etc. complete including filling silicon all around of frame & wall joints as per architectural drawings and the directions of Engineer-incharge. Wall thickness of aluminium 16 guage, ( Rates are inclusive of providing and fixing 5mm thick float glass for fixed portion and 4mm thick float glass for openable portion Providing & fixing PVC Soil & Waste pipes ISI marked,/SWR jointed with solvent cement/rubber ring joints including all specials such as bends, tees reducers etc., with or without door as required, including any cutting & making good of floors/walls that may be necessary, clamps and stays as per requirements. The cost also includes levelling of sewer pipes with sand bed (below the pipe) and with PCC covering etc complete 110mm dia 6KG/CM2 : Rmt Providing & fixing tripple layer HDPE water tank Capacity of standard make such as ISI marked with suitable LTRS 2 16 2000 cover and locking arrangement including the cost of sockets and check nut for inlet out let,scour & over flow 25 26 27 pipe, valves for inlet & outlet pipes, making a PCC foundation complete in all respect. Providing and fixing white vitrous china urinal partition complete with all necessary screw and fittings as Nos per drawing Providing and fixing 6 mm th mirror of approved make / quality and of required size with 6 mm th ply Sqmt backing and 40x40 mm moulding/ beeding all around, complete Providong and fixing granite stone for wash basins including cutting holes champhering the edges complete Sqmt as per the direction of site incharge, Basic cost of granite, Rs 150/ sqft) TOTAL NON SHEDULED ITEM -B GRAND TOTAL 11 2 3 2 RATE AMOUNT S.N. 1 2 3 4 5 6 PASSAGE , OTHER AREA AND EXTERNAL WORK DESCRIPTION OF ITEM Finishes Floor Tiles : Providing and laying Floor Tiles of minimum thickness 8 mm of approved make and colour, laid to pattern as per drawing, set in rich cement mortar 1:4, min 40mm thick With tile grout joints of approved width finished, in colored Epoxy tile grout, Roff chemicals/ bal/ Laticrete or equivalent make. including cement slurry complete with oxalic acid wash. Joints to run continuous horizontally and vertically. Basic cost Rs. 60/sqft, Seemless tiles PAINTING Applying one coat of cement primer of approved brand and manufacture on wall surface, cement primer Providing and applying birla putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete Wall painting with plastic emultion paint of approved and manufacture to give an even shade, two or more coats on new work TOTAL SCHEDULED ITEM NON SCHEDULED ITEM Repairing of fair face brick work to match with the existing one Fire DOOR, Constructing on site 8'.0" height and 6' 0" wide (approx) double shuttered flushed door comprising of 1-1/2 " thk. block board finished in luster paint from one side and other side finished in 1 mm thk. Laminate of ‘Royal Touch’, ‘Greenlam’, ‘Vir Laminates’ or equivalent brand as approved ,having a with T.W. edging finished in melamine polish, with necessary hardware including hinges and tower bolts brushed steel handle, , ’Godrej’/ doorset or equivalent brushed steel finish dead lock. UNIT QTY. sqmt 134 sqmt 178 sqmt 178 sqmt 178 sqmt 20 Nos 1 7 Providing and fixing powder coated (minimum thickness of powder coating 50 micron)aluminium work for windows and ventilators with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt /silicon etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed sqmt mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete including handles , friction hinges , stays etc. complete including filling silicon all around of frame & wall joints as per architectural drawings and the directions of Engineer-incharge. Wall thickness of aluminium 16 guage, ( Rates are inclusive of providing and fixing 5mm thick float glass for fixed portion and 4mm thick float glass for openable portion TOTAL NON SHEDULED ITEM -B TOTAL ( A+B) 12 132 RATE AMOUNT SERVICES SN DESCRIPTION OF ITEM 1 Providing and fixing chlorinated polyvinyl chloride (CPVC) pipe. Hving thermal stability for hot & cold water supplu including all CPVC plain and brass threded fittings including fixing the pipe with clamps at 1.00m sapcing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. 20mm nominal outer dia. Pipes( concealed) 25mm nominal outer dia. Pipes ( concealed) 32mm nominal outer dia. Pipes ( concealed) 40mm nominal outer dia. Pipes ( external) 50mm nominal outer dia. Pipes ( external) 65mm nominal outer dia. Pipes ( external) 80mm nominal outer dia. Pipes ( external) Supply & fixing gun metal gatel valve with CI wheel of approved quality. 25mm dia 32mm dia 50mm dia Constructing brick masonary man hole in cement mortar 1: 4 , R.C.C. top slab 1:2:4 mix, foundation concrete 1.a 1.b 1.c 1.d 1.e 1.f 1.g 2 2.a 2.b 2.c 3 UNIT QTY meter meter meter meter meter meter meter 56 0 52 34 26 50 40 Each Each Each 1 3 2 Each Each Each 6 6 1 Each 1 1:4:8 mix inside plastering 12 mm th with cement mortar 1:3 finished with floating coat of neat cement and 3.a 3.b 3.c 3.d 4 making channels in cement concrete 1:2:4 mix finished with floating coat of neat cement complete . Inside size, 1200mmx 900 mm and 900mm deep including C.I. cover 600x600mm with frame Extra for depth for man hole size 1200x 900 mm Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) Extra for depth for man hole size 900x 800 mm Supply & fixing in position ISI marked cast iron double flanged butterfly valves (PN 1 MPa) as per IS:13095, with SS disc, shaft, seating rings, internal fastening, nitrile rubber lining, nuts, bolts including transporting to worksite, 3 mm thick rubber gaskets etc. including testing, Complete as per drawings & directions of the Engineer-in-charge. 13 RATE AMOUNT SN DESCRIPTION OF ITEM UNIT QTY 4.a 4.b 5 5a 5b 5c 6 65 mm nominal dia 80 mm nominal dia Providing & fixing brass ball float valve with bronze floats of approved quality complete. 20 mm nominal dia 25 mm nominal dia 32 mm nominal dia Excavating trenches of required width for pipes, cable, etc including excavation for sockets and dressing of meter meter 1 1 Each Each Each 1 1 1 meter 1 7 Providing, laying and jointing glazed stone ware pipes grade class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1cement :1 fine sand) including testing of joints etc complete. 7a 8 150 mm diameter meter Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 gradded stone aggregate 40 mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 1 8a 9 150 mm diameter S.W.Pipe meter Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar Each TOTAL -A 1 sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by 6a 9a 4 4a ramming, watering, etc & disposing of surplus excavated soil as directed within the campus. All kinds of soil Pipes cables etc. exceeding 80 mm dia. But not exceeding 300mm dia. NON SCHEDULED ITEM Providing & installing tubing & Fittings for Nitrogen, RW,Vaccume & Zero Air Line. Gas Controller & Purification Panel :-Powder coated with indication sticker,pressure regulator,pressure gauges. Foer Nitrogen Misture trap with ,molecular sieve 13X and blue silica Gel. 14 Nos 1 1 RATE AMOUNT SN 5 DESCRIPTION OF ITEM UNIT Providing and fixing heavy duty SS316 12mm SS pretreated tubing with color coded sleeves including SS304 Rmt QTY 110 pipe sch for header including SS union, SS reucing Tee, SS Male connector,SS Ball Valve,SS Flange,SS Socket,SS Nipple ,Vaccum pressure gauge,SS Elbow,NRV,SS reducing union , SS line micronic filter,SS high pressure manifold for holding cylinder,SS high pressure wire breaded flexible pigtails,cylinder mounting 6 bracket with crom plated chain,SS tube cap SS tube clamp,standards fittings like Nut,Ferrules etc complete. Providing and fixing heavy duty SS316 6mm SS pretreated tubing with color coded sleeves including SS304 Rmt 30 pipe sch for header including SS union, SS reucing Tee, SS Male connector,SS Ball Valve,SS Flange,SS Socket,SS Nipple ,Vaccum pressure gauge,SS Elbow,NRV,SS reducing union , SS line micronic filter,SS high pressure manifold for holding cylinder,SS high pressure wire breaded flexible pigtails,cylinder mounting bracket with crom plated chain,SS tube cap SS tube clamp,standards fittings like Nut,Ferrules etc complete. Providing & fixing tripple layer HDPE water tank Capacity of standard make such as ISI marked with suitable cover and locking arrangement including the cost of sockets and check nut for inlet out let,scour & over flow pipe, valves for inlet & outlet pipes, making a PCC foundation complete in all respect. 1000lt capacity 8 Providing and fixing HDPE pipes for Lab waste water system, as per IS 14333, PE 80 working pressure 8kg/Sq cm, including excavating trenches, covering the pipe with cement concrete and filling the excavated portion making good in all respects complete 8.a 50 mm dia 8.b 75 mm dia 8.c 160 mm dia 9 Making and constructing 1mt x 3 mt plateform for GDS and compressor machine with brick work all around and concrete on top with a floating coat of neat cement including ,making & fixing MS cage from 3 sides with MS angle & 50mmx50mm welded wire mesh for fixed & openable portion. 10 Constructing brick masonary man hole in cement mortar 1: 4 , foundation concrete 1:4:8 mix inside plastering 12 mm th with cement mortar 1:3 finished with floating coat of neat cement and making channels in cement concrete 1:2:4 mix finished with floating coat of neat cement complete . 10.a Inside size 300mm x300mm 450 deep with C.I. cover TOTAL NON SHEDULED ITEM -B TOTAL ( A+B) 7 15 LTRS 3000 Rmt Rmt Rmt Nos 30 40 52 1 Each 6 RATE AMOUNT Electrical S.N. 1 1.1 a 1.2 1.3 1.4 1.5 a b c d e f g h i j k 1.6 a QTY UNIT RATE DESCRIPTION OF ITEM WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 120 Point Group C Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the 8 Point point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core 2000 Metre cable for loop earthing as required. Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core 2200 Metre cable for loop earthing as required. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 0 Metre 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 0 Metre 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 120 Metre 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 0 Metre 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 0 Metre 2 X 10 sq. mm + 1 X 10 sq. mm earth wire 0 Metre 2 X 16 sq. mm + 1 X 16 sq. mm earth wire 0 Metre 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 0 Metre 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 0 Metre 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 0 Metre 4 X 10 sq. mm + 2 X 10 sq. mm earth wire 0 Metre 4 X 16 sq. mm + 2 X 16 sq. mm earth wire Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel conduit as required. 0 Metre 2 Pair 16 AMOUNT b 1.7 1.8 a b c d e 1.9 a b c 1.10 a b c d e f i j 1.11 a b c d 4 Pair Supplying and drawing of CAT 6 LAN Cable in the existing surface/ recessed steel conduit as required. Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm 25 mm 32 mm 40 mm 50 mm Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep 100 mm X 100 mm X 60 mm deep 200 mm X 125 mm X 60 mm deep Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch 2 way 5/6 amps switch 15/16 amp switch 3 pin 5/6 amp socket outlet 6 pin 15/16 amp socket outlet Telephone socket outlet Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) 3 Module (100mmX75mm) 4 Module (125mmX75mm) 6 Module (200mmX75mm) 17 750 Metre 1200 Metre 0 400 150 0 100 Metre Metre Metre Metre Metre 25 15 10 Each Each Each 0 0 240 0 240 15 Each Each Each Each Each Each 14 Each 20 Each 40 0 0 240 Each Each Each Each e f 1.12 1.13 1.14 1.16 2 2.1 b c d 2.2 a b c d e f 8 Module (125mmX125mm) 12 Module (200mmX150mm) Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.(For window AC) 0 0 Each Each 0 each Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" 0 curve TP MCB complete with connections, testing and commissioning etc. as required. Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, 15 with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, 3 with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. MCCB, MCB & DB'S Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 1 6 way (4 + 18), Double door (Nano Lab LDB) 3 8 way (4 + 24), Double door (ChemLab, MSc Lab, Other area LDB) 0 12 way (4 + 36), Double door Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 60 Single pole 0 Single pole and neutral 0 Double pole 3 Triple pole 4 Triple pole and neutral 30 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 18 each Each Each Each Each Each Each Each Each Each Each Each 2.3 a b 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 0 40 amps 4 63 amps Earthing Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with 4 charcoal/ coke and salt as required. Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. 2 with charcoal/ coke and salt as required. Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including 10 connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including 10 connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 20 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 4 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a b c d 3½ X 16sq. mm (25mm) 3½ X 95 sq. mm (45mm) 3½ X 120 sq. mm (45mm) 3½ X 300 sq. mm (70mm) Each Each Set Set Metre Metre Metre 80 Metre Metre 8 10 12 2 Each Each Each Each TOTAL SCHEDULED ITEM 1 a TOTAL -A NON SCHEDULED ITEM Supply & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in Existing Cable trays including accessories etc as required. 250 Metre 4 X 16 sq. mm 19 b 2 2.1 a b 2.2 a b 2.3 300 Metre 3½ X 95 sq. mm MV CABLE LAYING Supply & Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 80 Metre 3½ X 120 sq. mm 80 Metre 3½ X 300 sq. mm Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 0 Each 40 amps 4 Each 63 amps Main/sub L T Distribution Panel Supply Installation testing & commissioning of Distribution Panel made out of 14 SWG sheet steel, aluminum bus bars, separate Earth bus to be provide throughout the length of the panel.The incoming & 1 Set outgoing feeder shall be accomdated in modular multitier arrangement, Adequate size cable alley,powder coated ,earthing, danger plates etc. with following acessories Incomer -1 1 No 400A 4P MCCB with accessories 1 No Ammeter with 3CTs & ASS 1 No Voltmeter with 3 Control MCB & VSS 3 No Pse Indicating Light with 3 Control MCB 1 No KWH Meter Incomer - 2 1 No 200A 4P MCCB with accessories 1 No Ammeter with 3CTs & ASS 1 No Voltmeter with 3 Control MCB & VSS 3 No Pse Indicating Light with 3 Control MCB 1 No KWH Meter Bus Coupler 1 No 200A 4P MCCB with accessories Bus Bar rating 250A Aluminum Outgoings 1 No 160A 4 P COS 5 No 160A TPN MCCB 20 2.4 2.5 2.6 4 No 63A TPN MCCB 1 No 100A TPN MCCB 3 No 63A TPN MCB Supply Installation testing & commissioning of Distribution board made out of 14 SWG sheet steel, aluminum bus bars, separate Earth bus to be provide throughout the length of the panel.The incoming & outgoing shall be accomdated in modular multitier arrangement, Adequate size cable alley,powder coated ,earthing, danger plates etc. with following acessories (Chem Lab Power DB) Incomer 1 No 160A TP MCCB 3 No Pse Indicating Light with 3 Control MCB 3 No 63A TPN MCB with ELCB further feed to following 36 No SP MCB Supply Installation testing & commissioning of Distribution board made out of 14 SWG sheet steel, aluminum bus bars, separate Earth bus to be provide throughout the length of the panel.The incoming & outgoing shall be accomdated in modular multitier arrangement, Adequate size cable alley,powder coated ,earthing, danger plates etc. with following acessories (MSc Lab Power DB) Incomer 1 No 160A TP MCCB 3 No Pse Indicating Light with 3 Control MCB 3 No 63A TPN MCB with ELCB further feed to following 51 No SP MCB Supply Installation testing & commissioning of Distribution board made out of 14 SWG sheet steel, aluminum bus bars, separate Earth bus to be provide throughout the length of the panel.The incoming & outgoing shall be accomdated in modular multitier arrangement, Adequate size cable alley,powder coated ,earthing, danger plates etc. with following acessories (Other Area Power DB) Incomer 1 No 160A TP MCCB 3 No Pse Indicating Light with 3 Control MCB 3 No 63A TPN MCB with ELCB further feed to following 24 No SP MCB 21 1 Each 1 Each 1 Each 2.7 2.9 3 3.1 a b c 3.2 a a b Supply Installation testing & commissioning of Distribution board made out of 14 SWG sheet steel, aluminum bus bars, separate Earth bus to be provide throughout the length of the panel.The incoming & outgoing shall be accomdated in modular multitier arrangement, Adequate size cable alley,powder coated ,earthing, danger plates etc. with following acessories (Nano Lab Raw Power DB) Incomer 1 No 160A TP MCCB 3 No Pse Indicating Light with 3 Control MCB 1 No 63A TPN MCB 3 No 63A TPN MCB with ELCB further feed to following 15 No SP MCB Supply Installation testing & commissioning of Distribution board made out of 14 SWG sheet steel, aluminum bus bars, separate Earth bus to be provide throughout the length of the panel.The incoming & outgoing shall be accomdated in modular multitier arrangement, Adequate size cable alley,powder coated ,earthing, danger plates etc. with following acessories (Nano Lab UPS Power DB) 1 Each 1 Each Incomer 1 No 160A TP MCCB 3 No Pse Indicating Light with 3 Control MCB 3 No 63A TPN MCB with ELCB further feed to following 18 No SP MCB CABLE TRAYS & RACE WAYS Supplying and installing following size of perforated galvanised M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 Metre 100 mm width X 50 mm depth X 1.6 mm thickness 60 Metre 300 mm width X 50 mm depth X 1.6 mm thickness 0 Metre 450 mm width X 50 mm depth X 2.0 mm thickness Supplying and installing following size of perforated galvanised M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 8 Each 100 mm width X 50 mm depth X 1.6 mm thickness 2 Each 300 mm width X 50 mm depth X 1.6 mm thickness 0 Each 450 mm width X 50 mm depth X 2.0 mm thickness 22 3.3 a 4 A 4.1 a 5 5.1 5.2 5.3 5.4 5.5 5.6 6 Supplying and installing following size of galvanised M.S. raceway with cover , joined with connectors, laid in floor including bolts & nuts, etc as required. 70 300 mm width X 50 mm depth X 2.0 mm thickness Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 25 Computer Socket outlet Supply & Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2 Upto 450 mm sweep 2 Extra for Supply & fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. MANUALLY OPERATED ELECTRIC FIRE ALARM SYSTEM Smoke detectors Supply and installation of Analog addressable optic smoke detectors(multi sensor) suitable for detecting a wide range of smoke from slow smouldering and fast flamming fire.The detector shall have following 50 features and also including supply of all fixing materials complete as required. Heat detectors Supply and installation of analog addressable heat detectors.The detectors shall have the following 6 features: Electronic Hooters 1 Supply, installation, testing and commissioning of Anologue addressable loop sounders. Manual call station Supply and installation of Addressable manual call station with in-built monitor module and press/break and resettable capability constructed of high impact LEXAN sheet with clearly visible operating instructions on 8 the cover and the word "FIRE" shall appear on the front and suitable for surface mounting/flush mounting as conplete as required. Fire alarm control panel Supply, installation,testing and commissioning of micro processor based,digital,distributed processing real time,multi tasking and multi - user type 2 Loop Analogue addressable type fire alarm control panel (FACP) 1 and control panel shall have the following features including supply of all fixing materials interconnections earthing complete as required. P/ F AC for NANO lab including all ducting , diffussers complete 8 ton ceiling mounted indoor unit. ( Hitachi,Daikin make) 1 23 Metre Each Each Each Nos Nos Nos Nos Nos Nos 7 8 a b c d f g 9 10 11 P/fixing 1.5 ton spilit AC for laminar flow room with all neccessary piping and drain pipe system, ( Hitachi, L.G.) LIGHTING FIXTURE Supply & Fixing of ceiling fan 1200mm sweep 1 x10 W Recess Mounted CFL Downlighter FBH 120 philips 4 x 18 W Recess Mounted Luminiare TBS 088/4x18 1X 40 W T5 Light Fixture (wipro) 2 X 28 W T5/ (1200 x 150 MM) Pendant Mounted Luminaire ( wipro) 2 X 36 W Surface Mounted Mirroe Optic Luminaire TCS 605/2 x36 EBT UPS 40 kva ( Three ph in , three ph out)Hitachi make Providing and fixing M.S. hook S type including cutting of slab and fixing the hook with existing steel in slab 14 8 16 10 20 50 1 60 Providing and fixing M.S. pipe for fixing of lights and fan wherever required . 300 Rmt TOTAL NON SHEDULED ITEM -B TOTAL ( A+B) 24 1 Nos Nos Nos Nos Nos Nos Nos Nos Nos LIST OF APPROVED MATERIALS, FOR Civil , interior and plumbing work S.No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Item Description Makes Name Reinforcement and structural steel Cement White cement M.S Pipe (Railings) Admixtures and Epoxy Flooring Ceramic Tiles Vitrified Tiles Distempers / Synthetic Enamel, Plastic Emulsion Polyurethane, Automotive Paints, Epoxy Paints & Primers Fire Resistant Paint Flush Doors Laminates Putty Block board / Ply Door Closers, Floor Springs Hardware Veneer Float Glass Mirror GI Pipe / MS Pipe Pre Laminated Board Silicon Sealant False Ceiling With T-Section Frame Work Cement Primer Sealing Component CP Fittings Sanitary Fittings Kamdhenu , Rathi JK / Birla/ Shree J.K white or Birla White Cement Jindal / Prakash Aquamix / Bal Endura / SDC India/Lattimore Kajaria / Nitco / Jhonson / Pavit Kajaria / Nitco / Jhonson /Pavit ICI Dulux, Berger, Asian VIPER by Navair Pvt. Ltd Merino / Orchid / Sonear / Green Merino / Greenlam / Century / Vergo Birla White / Shriram/JK Green Ply / Merino / Sonear/ Bhutan Ozone / Briton/ ISI mark Ozone / Hettich / Kaff Green / Sonear/ Vergo Modi /ASAI / Saint - Gobain ASAI, Saint Gobain, Modiguard Tata / GST, Jindal, BEC Bajaj / Action / Sonear / Merino / Greenlam Dow Corninger Or Approved Equivalent / 3M Armstrong / AMF / USG ICI Dulux, Berger, Nerolac Dow Corning/ Ge Bayer Silicon Ltd. Pidilite / 3m Jaquar / Hindware Hindware / ISI MARKED 25 S.No. 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 Item Description Makes Name SS Sink Nirali / Jayna Toilet Accessories I.E Soap Dispenser, Paper Towel Dispenser ISI marked G.I. Pipes Fittings K.S. / Unik / R Brand CPVC Pipes ASTRAL/ SUPREME HDPE pipe SUPREME/ ISI marked Electrical Items Switch Gear (MCCB/MCB/ ELCB) L&T/ABB/Schneider/Havells Cable & Wires Polycab/Havells Light Fitting & tubes/ CFL Phillips/Wipro/Bajaj Fan/Exhaust Fan Crompton/Orient/Havells MS conduit BEC/ ISI Marked Conduit accessories Rama/ Noble Modular switch & socket/ fan regulator Schneider/ M.K/ Crabtree MCB DB L&T/ABB/Schneider/Havells Instrumentation cable Finolex/ delton/ D-Link Metering Elmeasure/ AE Indicating lamps L&T/ABB/Schneider/Havells Change Over switch HPL Fire Alarm ANG INDIA/System server 26