Boom Bar Installation Guide (PDF 417Kb)
Transcription
Boom Bar Installation Guide (PDF 417Kb)
JDR Software Services Limited Oaktree Paddock, Stockley Lane Calne, Wiltshire, SN11 0NQ Tel: 01249 820138 Web: http://www.jdrsoftware.co.uk Email: [email protected] LIGHTWEIGHT BOOM BAR (MK 1) INSTALLATION GUIDE Reg. Office: Oaktree Paddock, Stockley Lane, Calne, Wiltshire. SN11 0NQ Company Reg. No. 3734057 Vat Reg. No. 729 0839 11 Welcome to the installation guide for the JDR Software Services Limited Lightweight Boom Bar. This guide will show you what materials you should have received with this package and how to assemble them into a fully functional lightweight Boom bar. If you require assistance or have parts missing from this boom bar, don’t hesitate to call us on 01249 820138. PARTS: The Entire Equipment This is the entire equipment you will need when installing the JDR Software Systems Ltd Lightweight Boom Bar. Further details of parts needed are shown below. The Projection End This shows the safety cap on the top of the pole, this is removable and as such enables the installer to place the cables through the slot provided. The circular hole shown is provided to enable the user to hang projectors from when planning offices, halls or classrooms. The Eye The eye is used for connecting the catenary wires to the pole securely. When placing the eye into the pole, ensure the bolts on the top and bottom of it are tightly fastened. Reg. Office: Oaktree Paddock, Stockley Lane, Calne, Wiltshire. SN11 0NQ Company Reg. No. 3734057 Vat Reg. No. 729 0839 11 The Eye With Catenaries Looped Through This picture shows the components you require to connect the catenary wires to the eye in the pole (Four wire clamps, One eye, Two catenary wires). The Wall-End This end of the bar will slot over the base (shown below) and is part of the main boom bar. The slot is for placing cables through the bar, either VGA, SVGA or AC cables. The Base This is the base for connecting the bar to the wall. This base plate supplied will be this long, but it is recommended that if you have a longer boom bar that you purchase a longer base plate to reduce the bow of the bar. Reg. Office: Oaktree Paddock, Stockley Lane, Calne, Wiltshire. SN11 0NQ Company Reg. No. 3734057 Vat Reg. No. 729 0839 11 The Wire Tensioners The catenary wire tensioners, two of these are supplied with each pack. These are used to create tension in the catenary wires to ensure that the boom bar stays perpendicular to both the wall and the floor. Catenary wire bundle This bundle includes enough wire to connect the boom bar end to the wall three times. This bundle also includes the bolts to connect the wire to the wall, and the tensioners, along with the actual wires Reg. Office: Oaktree Paddock, Stockley Lane, Calne, Wiltshire. SN11 0NQ Company Reg. No. 3734057 Vat Reg. No. 729 0839 11 INSTALLATION: Step 1: Ensure the area is clean and tidy and that there is sufficient room to fix the boom and catenary wire connections. Ensure that the wall is strong enough to support the catenary wires and the weight allowance for any objects you wish to hang from the end of it. Step 2: Clearly identify and mark the centre position of the pole mount using a pencil. From this mark, use the base plate to mark clearly the place where you need the screws to be. Step 3: Mark and Drill two holes, which correspond to the two holes on the base plate for the boom bar (base plate and screws provided in pack). Reg. Office: Oaktree Paddock, Stockley Lane, Calne, Wiltshire. SN11 0NQ Company Reg. No. 3734057 Vat Reg. No. 729 0839 11 Step 3a: Attach the base to the wall with the two screws provided. Use a washer in-between the base plate and screw head to ensure a strong fixture Step 4: Measure the holes for catenary wires from the central point of the base plate and mark with a pencil where the hooks need to be Step 5: Fit wall hooks for catenary wires and tighten with spanner. After doing this, ensure that the wall hooks are securely in place and the correct way up. Reg. Office: Oaktree Paddock, Stockley Lane, Calne, Wiltshire. SN11 0NQ Company Reg. No. 3734057 Vat Reg. No. 729 0839 11 Step 6: Dangle the catenary wires from the wall hooks just placed, ensuring that the wires are neatly placed against a wall so that no-one trips upon them. Step 7: Thread required cables through the pole using the slots provided. These could be VGA, SVGA, AC or sound cables used for projectors or other media devices. Step 8: Insert the centre pin. Make sure that the wires are not twisted, as this will decrease the amount of weight the boom bar can hold. Reg. Office: Oaktree Paddock, Stockley Lane, Calne, Wiltshire. SN11 0NQ Company Reg. No. 3734057 Vat Reg. No. 729 0839 11 Step 9: Place the pole onto the mount ensuring it is well supported from below (whether by scaffold or someone holding it). Step 9a: Ensure both tensioners are set in the mid position, and are capable of both tensioning and releasing tension in the wire. Step 10: Pass the catenary wires through the eye and create a loop for each wire, this will help strengthen the wire. Tension the catenary wires until the boom bar is perpendicular to the floor and wall. Reg. Office: Oaktree Paddock, Stockley Lane, Calne, Wiltshire. SN11 0NQ Company Reg. No. 3734057 Vat Reg. No. 729 0839 11 What catenary wires look like when attached Step 11: Affix your chosen projector onto the end of the boom bar using the conveniently placed hole. Step 12: Congratulations, you have now finished installing your Lightweight Boom Bar system. JDR does not accept liability for any problems or malfunctions with this unit once installed. Reg. Office: Oaktree Paddock, Stockley Lane, Calne, Wiltshire. SN11 0NQ Company Reg. No. 3734057 Vat Reg. No. 729 0839 11 SPECIFICATION TABLE: Boom Bar Length Catenary Wire Location Catenary Wire Length Wall Bracket Length Wall Bracket Height Weight Wire Tension Slot Size Slot Distance From End Of Bar Minimum Recommended Value 1.0 m 1.0 m (Up) 1.0 m (Out) 3.0 m 0.1 m 0.0 m (Vertical) 2.5 m (Horizontal) 0.0 Kg 2 N/m 0.0 Cm x 0.0 cm No slots for wires 0.0 M (The slot is placed at the end of the bar nearest to the wall) Maximum Recommended Value 10.0 m 10.0 m (Up) 10.0 m (Out) 30.0 m 1.0 m 10.0 m (Indoor Horizontal) 15.0 m (Outdoor Horizontal) 10.0 Kg 25 N/m (2 x) 5.0 cm x 2.0 cm Large enough for VGA/SVGA and power cables 10.0 m (The slot is placed 10.0 m from the wall) Reg. Office: Oaktree Paddock, Stockley Lane, Calne, Wiltshire. SN11 0NQ Company Reg. No. 3734057 Vat Reg. No. 729 0839 11