Manual
Transcription
Manual
Canada USA 9A Aviation Point-Claire, QC H9R 4Z2 PH 514-428-8090 Fax: 514-428-8899 1801 Parkway View Drive Pittsburgh, PA 15205 PH: 412-788-2830 FAX: 412-788-4890 Series DRG Paddle Flow Sensor www.kobold.com Precautions • User's Responsibility for Safety: KOBOLD manufactures a wide range of process sensors and technologies. While each of these technologies are designed to operate in a wide variety of applications, it is the user's responsibility to select a technology that is appropriate for the application, to install it properly, to perform tests of the installed system, and to maintain all components. The failure to do so could result in property damage or serious injury. • Material Compatibility: The DRG process wetted parts for the various body materials are stated below. Make sure that the DRG is chemically compatible with the application liquids. While the sensor’s outer housing is liquid resistant when installed properly, it is not designed to be immersed. It should be mounted in such a way that it does not normally come into contact with fluid. • Proper Installation and Handling: Use a proper sealant with all installations. Never overtighten the sensor within its fittings. Always check for leaks prior to system start-up. • • Wiring and Electrical: This is an electrically operated device and only properly trained personnel should install and maintain this product. Be sure that the power supplied to the sensor is appropriate for the electronics supplied. Electrical wiring should be performed in accordance with all applicable national, state and local codes. Flammable, Explosive and Hazardous Applications: The DRG is not an explosion-proof design. It should not be used in applications where an explosion-proof design is required. • Make a Fail-Safe System: Design a fail-safe system that accommodates the possibility of sensor or power failure. In critical applications, KOBOLD recommends the use of redundant backup systems and alarms in addition to the primary system. • Temperature and Pressure: The DRG is available in several material combinations. Temperature and pressure maximums vary depending upon the material selected. Operation outside these limitations will cause damage to the unit. Specifications Electrical (continued) Output L342: Accuracy: ±3.0% of full scale Wetted Parts DRG-11: Bronze, Acrylic, PTFE, Ceramic, NBR DRG-12: Bronze, PTFE, Ceramic, NBR DRG-14: 316SS, Acrylic, PTFE, Ceramic, FKM DRG-15: 316SS, PTFE, Ceramic, FKM DRG-18: PP, PTFE, Ceramic, NBR Max. Pressure: DRG-18: 100 PSIG DRG-11, 14: 230 PSIG DRG-12, 15: 580 PSIG Temperature Range: -10°F to +176°F Electrical Protection (all versions):NEMA 4X/IP 65 4-20 mA, 2-wire, Rmax < 500 ohms, 24 VDC Connection: 4 pin, M-12 Micro-DC plug, male Output L343: 4-20 mA, 3-wire, Rmax < 500 ohms, 24 VDC Connection: 4 pin, M-12 Micro-DC plug, male Output L442: 4-20 mA, 2-wire, Rmax < 500 ohms, 24 VDC Connection: DIN 43650 (Hirschmann) plug Outputs C34P & C30R Output C34P: 4-20 mA, 3-wire, Rmax < 500 ohms + 1 PNP switch Electrical (refer to model number table for model codes and descriptions for each output type) Output C30R: 2 PNP switches Output F300 PNP Pulse Output: Display: 3-digit LED Switch Type: PNP open collector, 24 VDC, 300 mA max. Connection: 5 pin, M-12 Micro-DC plug, male PNP open collector, 25mA max. Input Power: 14-28 VDC Connection: 4 pin, M-12 Micro-DC plug, male Power Supply: 24 VDC ±20%, 80 mA max. PDF Rev. 12/13 DRG_manual_12-13 Part Number Decoding Flow Range GPM Water Nominal freq. at f.s. (Hz) 0.15 - 3 0.15 - 6.6 0.3 - 8 0.6 - 12 0.8 - 23 1.5 - 37 3 - 37 120 217 184 215 265 116 180 Material Combination & Flow Range Fitting Output/Electronics DRG-11 DRG-12 DRG-14 DRG-15 DRG-18 ..50 ..55 ..60 ..65 ..70 ..75 ..80 ..50 ..55 ..60 ..65 ..70 ..75 ..80 ..50 ..55 ..60 ..65 ..70 ..75 ..80 ..50 ..55 ..60 ..65 ..70 ..75 ..80 ..50 ..55 ..60 ..65 ..70 ..75 ..80 N1=1/8” NPT F300=Frequency output, Micro-DC plug L342=4-20 mA, 2 wire, Micro-DC plug N2=1/4” NPT L343=4-20 mA, 3 wire, Micro-DC plug L442=4-20 mA, DIN 43650 plug N4=1/2” NPT C34P=Compact Electronics, 4-20 mA w/1 PNP switch N5=3/4” NPT C30R=Compact Electronics, 2 PNP switches N6=1” NPT Accessories Part Number 807.037=Mating 4-pin Micro-DC plug with 6 ft. cable for output F300, L342, & L343 Part Number 807.007=Mating 5-pin Micro-DC plug with 6 ft. cable for output C34P, & C30R Electrical Connection for Output C30R & C34P (5-wire Micro-DC plug) Electrical Connection for Output F300 and L343 (3-wire transmitters) Cable: Brown= Pin 1; White= Pin 2; Blue= Pin 3; Black= Pin 4; Gray= Pin 5 Switch out 2 GND GND 2 1 3 4 5 C30R Electrical Connection for Output L342 (2-wire 4-20 mA) +24 VDC + 24 VDC power power + (0)4-20 mA GND Switch out 1 GND + 24 VDC power 1 2 3 5 4 Switch out 1 C34P Electrical Connection for Output L442 (2-wire 4-20 mA) Cable Brown = +24 VDC Black = 4-20 mA out Mechanical Installation Piping Preparation: Piping should be rigidly supported at both the inlet and outlet of the sensor to prevent potential damage due to excessive stress on the sensor fittings. In order to ensure that the fluid flow profile is fully developed and symmetrical, a minimum straight piping run of 20 pipe diameters upstream and 5 diameters downstream of the sensor are required. The straight runs should be free of tees, elbows, valves, reducers and other disturbances. Pumps: All pumps cause pulsations in the fluid. Centrifugal pumps cause the least amount of pulsations in the fluid and positive displacement or reciprocating pumps cause the most. In order to minimize the effect of these pulsations on sensor accuracy, the sensor should be located as far away from the pump as possible. A pulsation dampener or accumulator may be used to dampen pulsations if required. If the fluid pulsations cannot be reduced to an acceptable level, a field calibration to determine the new K-factor for the sensor installed in a pulsating system may be required. Viscosity: All flow range and calibration data assume water as the flow media. All paddle type transducers are affected by viscosity and higher viscosities tend to make the paddle wheel turn slower for a given flow rate. This results in a lower K-factor when the sensor is used with a viscous media (i.e. viscosity > 10 cSt.) and the calibration data provided for water flow is no longer valid. If the sensor is to be used with viscous media, a field calibration is required to determine the new K-factor for the sensor. Field calibration: For frequency output versions, a simple field calibration may be performed to determine a new Kfactor when the sensor is to be used in a manner in which the above specified calibration information does not apply (i.e. use with viscous or pulsating media, insufficient straight run, etc.). With the sensor installed in the system, dispense a known quantity of the fluid to be measured while using a pulse counter to count the number of pulses generated during the dispense. This information can then be used to determine the new K-factor specific to your system and fluid. 4-20mA output and / or Compact Electronic versions have a preset output span that is not field adjustable.