FAAC XSH V1
Transcription
FAAC XSH V1
X S H M u l t i s e n s o r c a r d C a r d f o r t h e c o n n e c t i o n o f 4 s e n s o r s NOT USED SENSOR # 4 SENSOR # 3 SENSOR # 2 STD TEST 100Hz MONIT. TYPE SENSOR # 1 10 MIN 20 SEC MONIT. TIME Input 1: Green LED IN1 ASYNC SYNC MONIT. MODE 3 4 5 6 7 8 9 10 4SAFE = XPB ACTIV8 = XDT1, XV1, XBFA ON IN2 ON OFF RELAY DEBOUNCE LOGIC OUT 1 SENSOR TYPE 1+2 PUSH BUTTON: CONFIRM DIP SWITCH SETTING PASSIVE PASSIVE ACTIVE LOGIC OUT 2 4SAFE ACTIV8 ACTIVE 4 3 2 1 OUT1 Output 2: Red LED # SENSORS CONNECTED Output 1: Green LED OUT2 CONTROL UNIT DESCRIPTION Input 2: Red LED ON Door controller connector Sensor connectors 1 2 3 4 5 6 7 8 9 10 Yellow LED DIP-switches Confirmation push button LED SIGNAL GREEN ON Output 1 Input 1 RED ON Output 2 Input 2 LED switches ON during detection Active mode LED switches OFF during detection Passive mode YELLOW flashing Awaiting confirmation DIP-switch setting TECHNICAL SPECIFICATIONS Max. load current: 2A Supply voltage: 12 V DC - 24 V DC +10% (min. 16 V DC @ max. load current) Output to door controller: 2 galvanically isolated outputs (OPTOFET; UMAX= 42 V DC; IMAX= 100 mA) maximum output power dissipation: 200 mW off-state leakage current: 10 µA on-state maximum resistance: 20 Ohms Monitoring input from door controller: 1 galvanically isolated input (Optocoupler; max 30 V DC (6 mA)); voltage threshold: logic high: >10 V DC (2 mA); logic low: <1 V DC Input from each sensor: 2 non-isolated inputs Monitoring output to each sensor: 1 non-isolated output (UOUT= USUPPLY; IMAX= 50 mA) Monitoring response time: from 200µs to 50ms (depending on sensors & XSH setting) LEDs: red & green for status display of each connected sensor red & green for XSH output status display orange for DIP-switch status change display Norm conformity: EMC 2004/108/EC EN ISO 13849-1:2006 Performance Level "c”, CAT 2 EN 62061:2005 SIL 2 Temperature range: from -25° to +60° (for indoor use only) Dimensions: 70 mm (L) x 55 mm (H) x 25 mm (D) Housing material: ABS (translucent blue) Length of sensor cables: 2.70 m Length of power cable: 2.60 m Specifications are subject to changes without prior notice. 1/2 WIRING DOOR CONTROLLER XSH 1. 2. GREEN ON BROWN 1 2 3 4 5 6 7 8 9 10 YELLOW 24V DC GND SENSOR #4 SENSOR #3 SENSOR #2 SENSOR #1 CABLE TO DOOR CONTROLLER IN 1 OUTPUT 1 WHITE IN 1 GREY OUTPUT 2 IN 2 PINK IN 2 RED + BLUE 1. Connect the sensors (from 1 to 4) to the sensor connectors starting from the left using the cables that have connectors on both ends. - Attention! Never use the 4SAFE power cable to connect the XSH to the door controller. 2. Connect the cable with only one connector from the XSH to the door controller (see wiring diagram). DIP-SWITCH SETTINGS 1 2 3 4 Number of sensors connected to the XSH Type of sensor connected to the XSH Logic Output 1 ON ON Logic Output 2 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 sensor 2 sensors 3 sensors 4 sensors ON 7 Relay debounce avoids the bouncing of the relay contact during a monitoring request 42.8263 - V1 / 07.14 8 9 Monitoring cycle time in asynchronous mode Monitoring type ON ON Passive ON ON 1 2 3 4 5 6 7 8 9 10 ON 1 2 3 4 5 6 7 8 9 10 ON 1 2 3 4 5 6 7 8 9 10 ON 1 2 3 4 5 6 7 8 9 10 10 Only one type of sensor can be connected simultaneously. Do not mix sensor types. 1 2 3 4 5 6 7 8 9 10 Monitoring mode The monitoring has to be active on all connected sensors! ON 4SAFE=XPB OFF ACTIV8 = XDT1, XV1, XBFA ON 1 2 3 4 5 6 7 8 9 10 6 ON 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 5 ON OFF Active ON Passive Check the output logic on the connected sensors. The output logic has to be the same on the XSH and on all connected sensors (see LED-signal). OFF Active Check the output logic on the connected sensors. The output logic has to be the same on the XSH and on all connected sensors (see LED-signal). ON ON Recommended when the monitoring input is connected to a relay output on the door controller. OFF OFF Set to OFF for a faster response time. ON Asynchronous OFF Synchronous The XSH sends a monitoring request to all connected sensors every x seconds (according to DIP 8 setting), independent of the door controller. When the door controller sends a monitoring request to the XSH, it answers immediately giving the result of the last monitoring cycle. The XSH sends a monitoring request to all connected sensors only when the door controller sends a monitoring request to the XSH. The response time on monitoring request is dependent on response time of the connected sensors. ON 10 min The XSH sends a monitoring request to all connected sensors every 10 minutes (only in asynchronous mode). OFF 20 sec The XSH sends a monitoring request to all connected sensors every 20 seconds (only in asynchronous mode). Standard voltage ON monitoring OFF Signal output 100 Hz Most frequently used type of monitoring using test input. Only if your door controller is compatible with this type of monitoring. Not used YELLOW OFF After changing one or more DIP-switch settings, the yellow LED flashes. Confirm the new setting(s) by pushing the push button until the LED switches off. The setting is confirmed. FAAC S.p.A . - Via Calari, 10 40069 Zola Predosa - Italia - tel. +39 051 61724 - fax. +39 051 758518 - www.faacgroup.com Manufactured by BEA SA - LIEGE Science Park - Allée des Noisetiers 5 - B-4031 Angleur - T +32 4 361 65 65 - F +32 4 361 28 58 - [email protected] - www.bea.be