Technical DC 315 - Quadrant Spray Foam Technologies
Transcription
Technical DC 315 - Quadrant Spray Foam Technologies
DC 315 is Warnock Hersey mark. Products bearing the Warnock Hersey (WH-ETL) Mark indicate compliance to relevant building codes, association criteria, and product safety and performance standards. Utilizing the Warnock Hersey Mark on a product reflects a commitment to product safety, performance, and quality to inspectors, builders and end users. The mark also signifies that the product’s manufacturing site(s) undergo periodic follow-up inspections to ensure ongoing compliance of the originally certified product. Technical Downloads Application Guide Ventilation Guide Job Work Report DC 315 Technical Data Sheet DC 315 Sales Sheet DC 315 MSDS DC 315 applied over Spray Polyurethane Foam (SPF), is an Alternative Barrier System in “Section 2603.9 Special Approval” as a thermal barrier. To use this alternative system, a manufacturer’s SPF applied with a protective coating must be tested to the criteria of an NFPA 286, UL 1715, UL 1040, or FM 4880 for the duration of 15 minutes by an accredited fire testing facility. Products that pass an ignition barrier tested under AC 377 Appendix X are not appropriate alternative thermal barriers and cannot not be used. Depending on your particular application, either ignition or thermal barriers are required by the International Building Code (IBC). DC 315 is the most tested and approved product in the world for use as an “Alternative Barrier Coating System" on (SPF). DC 315 has passed over 100 full scale NFPA 286 tests on the majority of foam brands manufactured in the U.S.A. A material safety data sheet, safety data sheet, or product safety data sheet is an important component of product stewardship and occupational safety and health. AY-126 Thermal Barriers and Ignition Barriers for the Spray Polyurethane Foam Industry. Food contact - NSF/ANSI 51(2009) Food Equipment, Materials-Formulation Review and Extraction Testing Food contact materials are intended or have the potential to come in contact with food. When these materials come in contact with food, there is the possibility of the chemical substances migrating from the food contact material to the food, which could be potentially harmful to human health. In response to this issue, many countries have implemented food contact regulations to ensure food safety. Companies must ensure their products comply with the applicable food contact regulations to keep their products on the market. CAL 1350 US standard for evaluating and restricting VOC emissions indoor air California Standard Section 01350 Specification (Feb 2010 version 1.1) is the most popular US standard for evaluating and restricting VOC emissions indoor air. Developed in California, more and more rating systems are referring to CA Section 01350. Collaborative for High Performance Schools (CHPS) DC 315 Warranty Warranty Approved (SPF) and Type Wet Dry Coverage Rate Test Rpt. with DC 315 as Alternative Thermal Barrier ES Report Quadrant, QuadFoam 500 OC 0.5 lb. 4 3 400 sq. ft. per gal Test Rpt. with DC 315 to Appendix X Ignition Barrier ESR 0271 QuadFoam CC 2 lb. 18 12 89 sq. ft. per gal ESR 0272 QuadFoam 500 OC 0.5 lb. 16 11 100 sq. ft. per gal Thermal Barrier - QuadFoam 500 OC 0.5 lb. 4 2 400 sq. ft. per gal 16 11 100 sq. ft. per gal Thermal Barrier - NatureSeal QuadFoam 500 OC 0.5 lb. ESR 0285 4 2 400 sq. ft. per gal Flashed with 4 mils of DC 315 primer before applying DC 315 QuadFoam NatureSeal 500 OC 0.5 lb. Flashed with 4 mils of DC 315 primer before applying DC 315 Thermal Barrier - QuadFoam CC 2 lb. ESR 0271 DC 315 Characteristics: Finish: Colors: Volume Solids: V.O.C.: Drying Time: Type of Cure: Flash Point: Reducer/Cleaner: Shelf Life: Packaging: Shipping weight: Application: Flat All orders ship in Ice Gray (White and Dark Gray available via special order) 67% 47 g/l @ 77°F & 50% RH to touch 1-2 hours to recoat 2 to 4 hours Coalescence None Water 1 year (unopened) 5 & 55 gallon containers 5 gallon pail - 58 lbs. 55 gallon drum - 640 lbs. Brush, roller, conventional and airless spray Competitive Advantages of Using DC 315 Include: DC 315 is the only 3rd party inspected fire protective coating for SPF Marked and Listed by Warnock Hersey Intertek W/N 20947 Single coat coverage reducing labor and material costs equaling higher profits Industry leading spread rate Passed CAL 1350 - safe for use in schools and high occupancy buildings Passed strict EPA – V.O.C. and AQMD air emission requirements (for all 50 states) Approved for Incidental Food Contact complies with NSF/ANS1-51 requirements of USDA Easily applied with a sprayer, roller, or brush with no complicated mixing 1 year shelf life Fast and easy clean-up, with no waste and fast turnaround time Compatible with any paintable construction material Meets Life Safety Code 101 Meets LEED’s point requirements No formaldehyde Testing and Certification: ASTM E84 - Flame Spread 0 Smoke 25 CAN/ULC S102 FSR 23 SDC 145 - (tested as a system over SPF) UL 1715, NFPA 286 - over 130 test passed CAN/ULC S 101 - 25 minutes as a system over SPF WH Listed - Spec ID 32890 DC 315 Certified Warnock Hersey Approved IBC Code-Compliant Thermal & Ignition Barrier Over Spray Foam Polyurethane (SPF). Products that pass an ignition barrier tested under AC 377 Appendix X are not appropriate alternative thermal barriers and cannot not be used. Depending on your particular application, either ignition or thermal barriers are required by the International Building Code (IBC). DC 315 is the most tested and approved product in the world for use as an “Alternative Barrier Coating System" on (SPF). DC 315 has passed over 100 full scale NFPA 286 tests on the majority of foam brands manufactured in the U.S.A. If a coating has not passed a full scale test on a manufacturer’s foam it cannot be used on that foam; there are no exceptions in the IBC Code!