[PL 009-011] I/A Series Multirange Pressure Transmitters
Transcription
[PL 009-011] I/A Series Multirange Pressure Transmitters
Parts List PL 009-011 April 2015 I/A Series® Multirange Pressure Transmitters — IGP25 Series with FoxCom™, HART, and FOUNDATION Fieldbus Communication Protocols — for Gauge Pressure Measurement — Style A Give instrument Model Code when ordering. *Parts preceded by an asterisk are recommended spare parts. See Recommended Spare Parts Summary section for quantities. TO ORDER PARTS, CALL 1-866-746-6477. PL 009-011 Page 2 NOTES 1 For Transmitter Assembly Topworks, refer to Figure 1. 2 For Transmitter Replacement Sensor Assemblies (not flameproof), refer to Figure 2. 3 For Flameproof Transmitter Replacement Sensor Assemblies, refer to Figure 3. 4 For Sanitary & Pulp/Paper Transmitter Replacement Sensor Assemblies, see Figure 4. 5 For Optional LCD Indicator Assembly, refer to Figure 5. 6 For Optional Custody Transfer Lock and Seal, refer to Figure 6. 7 For Optional Metric Process Connection, refer to Figure 7. 8 For Optional Block and Bleed Valve, refer to Figure 8. 9 For Optional Vent Screw, refer to Figure 9. 10 For Optional Conduit Thread Adapters, refer to Figure 10. 11 For Optional Pipe Mounting Sets used with Standard Transmitters, refer to Figures 11 and 12. 12 For Optional Pipe Mounting Sets used with Flameproof Transmitters, refer to 12. 13 For Pressure Seals used with IGP25 Transmitters, refer to Figures 13, 14, and 15. 14 For Integral Sanitary Process Connectors and Accessories, refer to Figure 16. 15 For Integral Pulp and Paper Process Connectors and Accessories, refer to Figure 17. 16 For Recommended Spare Parts Summary, refer to tables at end of document. PL 009-011 Page 3 MODEL CODE Model Code Description I/A Series, Multirange, Direct Connected Gauge Pressure Transmitter Model IGP25 Electronics Versions and Output Signal Intelligent; Digital FoxCom and 4 to 20 mA dc, Configurable (Version -D) Intelligent; Digital HART and 4 to 20 mA (Version -T) Intelligent; Digital FOUNDATION Fieldbus (Version -F) -D -T -F Structure Code - Select from one of the following eight groups: 1. Transmitter Only (no seals; see below for flameproof versions) Connection Sensor Fill Fluid Connection Type 316L ss 316L ss Silicone 1/2 NPT External Thread, 1/4 NPT Internal Thread 316L ss 316L ss Inert 1/2 NPT External Thread, 1/4 NPT Internal Thread 22 23 2. Transmitter Prepared for Foxboro Model Coded Seals (see below for flameproof versions) (a) Transmitter Prepared for Foxboro Direct Connect Seal; Silicone Fill in Sensor (b) Transmitter Prepared for Foxboro Direct Connect Seal; Inert Fill in Sensor and Seal (b) Transmitter Prepared for Foxboro Remote Mount Seal; Silicone Fill in Sensor (c) Transmitter Prepared for Foxboro Remote Mount Seal; Inert Fill in Sensor (c) D1 D2 S3 S4 3. Transmitters Prepared for non-Foxboro Seals (see below for flameproof versions) Transmitter Prepared for Remote Seal; Silicone Fill in Sensor (d) Transmitter Prepared for Remote Seal; Inert Fill in Sensor (e) SC SD 4. Transmitter with Sanitary Process Connections (f) ConnectionDiaphragm Fluid 316L ss 316L ss NEOBEE M-20 316L ss 316L ss NEOBEE M-20 316L ss 316L ss NEOBEE M-20 316L ss Nickel alloy (h) NEOBEE M-20 316L ss Nickel alloy (h) NEOBEE M-20 316L ss Nickel alloy (h) NEOBEE M-20 316L ss 316L ss NEOBEE M-20 316L ss 316L ss NEOBEE M-20 316L ss 316L ss NEOBEE M-20 Process Connector 1.5-in Tri-Clamp Type, Sanitary (g) 2.0-in Tri-Clamp Type, Sanitary (g) 3.0-in Tri-Clamp Type, Sanitary (g) 1.5-in Tri-Clamp Type, Sanitary (g) 2.0-in Tri-Clamp Type, Sanitary (g) 3.0-in Tri-Clamp Type, Sanitary (g) Mini Tank Spud Seal, 1 1/2-in ext. (g) (i) Mini Tank Spud Seal, 6-in ext. (g) (i) Mini Tank Spud Seal, 9-in ext. (g) (i) 5. Transmitter with Pulp and Paper Process Connections (f) ConnectionDiaphragm Fluid Connection Type 316L ss 316L ss Silicone Sleeve Type, 1-inch nominal 316L ss 316L ss Silicone Threaded Type, 1-inch nominal 316L ss 316L ss Silicone Sleeve Type, 1 1/2-inch nominal 316L ss 316L ss Silicone Threaded Type, 1 1/2-inch nominal 316L ss Nickel alloy (h) Silicone Sleeve Type, 1-inch nominal 316L ss Nickel alloy (h) Silicone Threaded Type, 1-inch nominal 316L ss Nickel alloy (h) Silicone Sleeve Type, 1 1/2-inch nominal 316L ss Nickel alloy (h) Silicone Threaded Type, 1 1/2-inch nominal 316L ss Nickel alloy (h) Silicone Threaded Type, 1 1/2-inch nominal (fits Ametek spud) 6. Flameproof Transmitter Only (no seals) Connection Sensor Fill Fluid 316L ss 316L ss Silicone 316L ss 316L ss Inert Clamps/Gaskets By User By User By User By User By User By User By Foxboro By Foxboro By Foxboro Clamps/Gaskets By Foxboro By Foxboro By Foxboro By Foxboro By Foxboro By Foxboro By Foxboro By Foxboro By Foxboro Connection Type 1/2 NPT External Thread, 1/4 NPT Internal Thread 1/2 NPT External Thread, 1/4 NPT Internal Thread 7. Flameproof Transmitter Prepared for Foxboro Model Coded Seals (a) Flameproof Transmitter Prepared for Direct Connect Seal; Silicone Fill in Sensor (b) (j) Flameproof Transmitter Prepared for Direct Connect Seal; Inert Fill in Sensor (b) (j) Flameproof Transmitter Prepared for Remote Mount Seal; Silicone Fill in Sensor (c) (j) Flameproof Transmitter Prepared for Remote Mount Seal; Inert Fill in Sensor (c) (j) TA T2 T3 TB T4 T5 M1 M6 M9 PA PB PC PD PE PF PG PH PJ 52 53 D5 D6 S5 S6 PL 009-011 Page 4 MODEL CODE Model Code (Continued) Description 8. Flameproof Transmitter Prepared for non-Foxboro Seals Flameproof Transmitter Prepared for Remote Seal; Silicone Fill in Sensor (d) (j) Flameproof Transmitter Prepared for Remote Seal; Inert Fill in Sensor (e) (j) Span Limits - Absolute or Gauge Pressure Units, as Applicable MPa psi bar or kg/cm2 0.0035 and 1.4 0.5 and 2000.035 and 14 0.035 and 14 5 and 20000.35 and 140 Model SH SJ D E (k) Conduit Connections and Housing Material 1/2 NPT Connection, Aluminum Housing PG 13.5 Connection, Aluminum Housing (Available with Electrical Safety Codes E, D, M, N, and P only) 1/2 NPT Connection, 316 ss Housing PG 13.5 Connection, 316 ss Housing (Available with Electrical Safety Codes E, D, M, N, and P only) M20 Connection, Aluminum Housing (Available with Electrical Safety Codes E, D, M, N, and P only) M20 Connection, 316 ss Housing (Available with Electrical Safety Codes E, D, M, N, and P only) 1 2 3 4 5 6 Electrical Safety ATEX II 1 GD, EEx ia IIC, Zone 0; or II 1/2 GD, EEx ib IIC, Zone 0/1 (Versions D and T only) ATEX FISCO, II 1 G, EEx ia IIC, Zone 0 (Version F only) ATEX II 2 GD, EEx d IIC, Zone 1 (l) (m) ATEX II 3 GD, EEx nL IIC, Zone 2 (Versions D and T only) ATEX FNICO, II 3 G, EEx nL IIC, Zone 2 (Version F only) ATEX Multiple Certifications (includes ATEX Codes E and N) (Versions D and T only) ATEX Multiple Certifications (includes ATEX Codes E, D, and N) (Versions D and T only) (l) (m) E E D N N M P CSA Certifications: (n) (o) Intrinsically Safe, Division 1, Classes I, II, & III; and suitable for Division 2, Classes I, II, & III (Versions D & T only) Zone Certified intrinsically safe, Ex ia IIC, and energy limited Ex nA II (Version T only) Explosionproof and dust-ignitionproof, Division I, Classes I, II, and III (All Versions) CSA Certifications: (l) (m) (o) Zone certified flameproof, Ex d IIC. Also all certifications of Code C above (All Versions) CSA Certifications: (p) Intrinsically safe, Division 1, Classes 1, 2, and 3; and Suitable for Division 2, Classes 1, 2, and 3. Zone certified Ex ia IIC and Ex nA II (Electronic Version -T only) FISCO Intrinsically safe, Division 1, Classes I, II, and III (Version -F only) FNICO Nonincendive, Division 2, Classes I, II, and III (Version -F only) C FM Approvals: (n) (o) Intrinsically Safe, Division 1, Classes I, II, & III; and Nonincendive, Division 2, Class I, II, & III (Versions D & T only) Zone approved intrinsically safe, AEx ia IIC (Version T only) Explosionproof and dust-ignitionproof, Division I, Classes I, II, and III (All Versions) FM Approvals: (l) (m) (o) Zone approved flameproof, AEx d IIC. Also all certifications of Code F above (All Versions). FM Approvals: (p) Intrinsically safe, Division 1, Classes 1, 2, and 3; and Nonincendive, Division 2, Classes 1, 2, and 3. Zone approved AEx ia IIC and AEx nA II (Electronic Version -T only) FISCO Intrinsically safe, Division 1, Classes I, II, and III (Version -F only) FNICO Nonincendive, Division 2, Classes I, II, and III (Version -F only) F B L G R IECEx FISCO, Ex ia IIC, Zone 0; Version F only (o) IECEx flameproof, Ex d IIC; All Versions (o) IECEx FNICO, Ex nL IIC, Zone 2; Version F only (o) T V U SAA intrinsically safe, Ex ia IIC, Zone 0. (Version T only) SAA nonincendive, Ex n IIC, Zone 2. (Version T only) H K Multi-marked for ATEX, CSA, and FM Intrinsically Safe Applications (with Electronic Version -T/HART only) W Optional Selections - see Descriptions below. Mounting Bracket Set (q) (r) Painted Steel Bracket with Plated Steel Bolts, 1/2 NPT (with Conduit Connection Codes 1 and 3 only) (s) Stainless Steel Bracket with Stainless Steel Bolts, 1/2 NPT (with Conduit Connection Codes 1 and 3 only) (s) Painted Steel Bracket with Plated Steel Bolts, PG 13.5 (with Conduit Connection Codes 2 and 4 only) (s) Stainless Steel Bracket with Stainless Steel Bolts, PG 13.5 (with Conduit Connection Codes 2 and 4 only) (s) Painted Steel Bracket with Plated Steel Bolts, M20 (with Conduit Connection Codes 5 and 6 only) (s) Stainless Steel Bracket with Stainless Steel Bolts, M20 (with Conduit Connection Codes 5 and 6 only) (s) -M1 -M2 -M3 -M4 -M5 -M6 PL 009-011 Page 5 MODEL CODE Model Code (Continued) Description Digital Indicator with Pushbuttons Digital Indicator, Pushbuttons, and Window Cover Vent Screw and Block & Bleed Valve (t) 316 ss Vent Screw in Process Connection Not available with: Options -G, -X1, and -X2; Pressure Seals; Sanitary and Pulp/Paper Process Connections; and Nickel alloy (h) Structure Codes 32, 33, 62, and 63 Block and Bleed Valve, Carbon Steel Block and Bleed Valve, 316 ss Block and Bleed Valve, 316 ss w/Monel Trim -V2 -V3 -V4 Electronics Housing Features External Zero Adjustment Custody Transfer Lock and Seal External Zero Adjustment and Custody Transfer Lock and Seal -Z1 -Z2 -Z3 Cleaning and Preparation Unit Degreased – for Silicone Filled Sensors only Not for Oxygen/Chlorine Service, Option -V1 to -V4, or Pressure Seals Cleaned and Prepared for Oxygen Service – for Inert Filled Sensors only Not with Option -V1 to -V4 or Pressure Seals -G -C1 -C2 -X1 -X2 Seal Surface Finish 15 Ra Seal Surface Finish (g) -F1 Instruction Books (Common MI, Brochure, and Full Documentation Set on CD-ROM is Standard) Without Instruction Book and CD - Only “Getting Started” Brochure is supplied -K1 Miscellaneous Optional Selections Low Temperature Operative Limit of Electronics Housing Extended Down to -50°C (-58°F) (w) R 1/2 Process Connection (1/2 NPT to R 1/2 Adapter) Not available with pressure seals, Nickel alloy (h) Sensors, or sanitary/pulp and paper process connections. Supplemental Customer Tag (Stainless Steel Tag wired onto Transmitter) Seventeen Year Warranty (x) l. m. n. o. -V1 -A1 -A2 -A3 -A4 Custom Factory Configuration Digital Output (4 to 20 mA Default if not selected) - available with FoxCom Only (Electronics Version -D) Full Factory Configuration (requires Configuration Form to be filled out) h. i. j. k. -L1 Conduit Thread Adapters (Not with Conduit Connection Codes 5 and 6) Hawke-Type 1/2 NPT Cable Gland for use with Conduit Connection Codes 1 and 3 (u) Plastic PG 13.5 Cable Gland for use with Conduit Connection Codes 2 and 4 (v) M20 Connector for use with Conduit Connection Codes 1 and 3 (u) Brass PG 13.5 Cable Gland (Trumpet-Shaped) for use with Conduit Connection Codes 2 and 4 (v) Process Connections G 1/2 B Manometer Process Connection Not available with Option -V1, pressure seals, or sanitary and pulp and paper process connections a. b. c. d. e. f. g. Model -J -R -T -W Both transmitter and pressure seal Model Numbers are required. Refer to PSS 2A-1Z11 A for pressure seal Model Codes. Direct Mount Seal Models that may be specified are PSTAD, PSFAD, and PSISD. Remote Mount Seal Models that may be specified are PSFPS, PSFES, PSFAR, PSTAR, PSISR, PSSCR, and PSSSR. For transmitters with silicone fill prepared for remote seal by others, specify Structure Codes 22 or 52. For transmitters with Inert fill prepared for remote seals by others, specify Structure Codes 23 or 53. Accessories used with Sanitary and Pulp and Paper Connections are ordered and supplied separately. See ACCESSORIES section. Option -F1 (15 Ra seal surface finish) is available with Structure Codes TA, TB, T2 to T5, M1, M6, and M9. The standard seal surface finish is 32 Ra. Equivalent to Hastelloy® C. Hastelloy is a registered trademark of Haynes International, Inc. Structure Codes M1, M6, M9 are supplied with clamps and gaskets. All spuds are accessories that are specified by part number. Requires selection of Electrical Safety Code D. Not available with Pulp and Paper process connections. Available with Sanitary Process Connections Structure Codes TA, TB, and T2 to T5; when used with these sanitary Structure Codes, the span limit is limited to 4.2 MPa (600 psi), or the rating of the Tri-Clamp type connector used, whichever is less. Only available with flameproof transmitter Structure Codes 52, 53, D5, D6, S5, S6, SH, and SJ. A cover lock is provided as standard with Electrical Safety Codes D, B, G, and P. Not available with flameproof transmitter Structure Codes 52, 53, D5, D6, S5, S6, SH, and SJ. Not available with Sanitary or Pulp/Paper process connections: Structure Codes TA-T5, M1, M6, M9, PA-PJ. PL 009-011 Page 6 PARTS p. Only available with Sanitary or Pulp/Paper process connections: Structure Codes TA-T5, M1, M6, M9, PA-PJ. q. Mounting sets not offered with direct mounted seals, or sanitary and pulp/paper process connections. However, if a direct mounted PSTAD threaded seal with a 1/4 NPT process connection is used, then a mounting set is recommended. r. Mounting Bracket Sets -M1 to -M6 are not available with ATEX Electrical Safety Codes D and P s. Mounting Bracket Sets -M1 to -M6 are available with all transmitter structures. t. Not available with sanitary and pulp/paper process connections. u. Available with Electrical Safety Codes E, D, M, N, and P only. v. Available with Electrical Safety Code E only. w. Not available with Electronics Version -V or Inert fill in sensor or seal. x. Standard Warranty is five years. Parts Figure 1. Transmitter Assembly ALWAYS A SOLID COVER ON THIS END 1 2 3 4 5 6 2 7 9 8 17 7 6 15 3 13 15 FLAMEPROOF SENSOR ASSEMBLY (Figure 3) 12 18 STANDARD SENSOR ASSEMBLY (Figure 2) SEE NOTE BELOW 11 10 SEE FIGURE 4 FOR OPTIONAL LCD INDICATOR Table 1. Parts for Figure 1 Part No. Qty. Part Name 1 Table 1 2 Cover, Electronics Housing 2 *3 X0118CC 1 Grease, Lubriplate (1-3/4 ounce tube) X0201FC 2 O-Ring, Cover Below 4 Screw, Terminal Block Assy, 0.138-32 x 0.750 4 5 1 X0133UW Steel Screw - used with Aluminum Housing X0133VP 316 ss Screw - used with 316 ss Housing Below 2 (WINDOW COVER WITH OPTIONAL LCD INDICATOR, SEE FIGURE 4) 14 Item SOLID COVER 1 Terminal Block Assembly D0149YB Electronics Versions -D and -T D0149HN Electronics Version -F PL 009-011 Page 7 PARTS Table 1. Parts for Figure 1 (Continued) Item Part No. 6 7 8 P0177JE 9 Qty. 1 D0162VJ 2 Screw Assembly, Earth (Ground), 0.164-32 x 0.750 X0144KR 1 O-Ring Below 1 Pipe Plug for Unused Housing Conduit Connection – see WARNING on next page Pipe Plug, Aluminum, 1/2 NPT; with Housing Code 1 B0139CA *10 11 *12 Part Name Cable, Power, Replaceable (Version -F only) B0139SK Pipe Plug, 316 ss, 1/2 NPT; with Housing Code 3 X0178GT Pipe Plug, 316 ss, PG 13.5; with Housing Codes 2 and 4 D0179FJ Pipe Plug, Aluminum, M20; with Housing Code 5 D0179FK Pipe Plug, 316 ss, M20; with Housing Code 6 Below 1 Electronics Module D0162UJ Digital FoxCom or 4 to 20 mA (Version -D) D0162UL Digital HART and 4 to 20 mA (Version -T) D0162UN Digital FOUNDATION Fieldbus (Version -F) D0197PS 1 Clip, Retention Below 1 Transmitter Replacement Sensor Assembly Figure 2 Standard Transmitter (not flameproof) Figure 4 Sanitary or Pulp/Paper Transmitters *13 Figure 3 1 Flameproof Transmitter Replacement Sensor Assembly 14 S0102BT 1 Plug, Poly (remove prior to Transmitter Installation) 15 Below 2 Screw, Captive, Pan Head, 0.138-32 x 0.615 D0162VM Steel Screw - used with Aluminum Housing D0166CY 316 ss Screw - used with 316 ss Housing 16 – 17 18 X0173YA 1 Washer, Ext. Ground, 0.196 ID, 0.383 OD X0174EK 1 Screw, Button Head; 0.164-32 x 0.25 long – Item 16 is intentionally not used NOTE For replacement sensor assemblies with sanitary or pulp and paper process connections, see Figure 4. Also see Figures 16 and 17 for vented housing with a membrane breather plug used only with the IGP25 Transmitter (Span Limit Code D only) having sanitary or pulp and paper process connections. PL 009-011 Page 8 PARTS Table 2. Housing Covers (Item 1) for Electronics Versions -D, -T, and -F Part Numbers for Electronics Housing covers Aluminum Housing Stainless Steel Housing Option -L1 See Note (a) Field Wiring End Electronics End Field Wiring End Electronics End NO YES D0162AP (b) D0162AP (b) D0162AP (b) D0162LH (c) D0162VD (b) D0162VD (b) D0162VD (b) D0162VH (c) a. Option -L1 provides the user with an LCD indicator along with a window cover. See Figure 4. b. Blind (solid) cover. c. Optional window cover with optional LCD indicator. See Figure 4. ! WARNING To maintain IP66 (IEC 529) and NEMA 4X protection, unused conduit opening must be closed with a metal plug. In addition, the threaded housing covers must be properly installed. Figure 2. Transmitter Replacement Sensor Assembly (See Figure 3 for Flameproof Transmitter Replacement Sensor Assemblies) (See Figure 4 for Replacement Sensor Assemblies for Transmitters with Sanitary or Pulp and Paper Process Connections) TYPICAL 2 1 ! WARNING Failure to install the proper Housing Neck O-Ring (Item 1) for CSA-labeled products violates ANSI/ISA 12.27.01 STANDARD 0.500-14 NPT CONNECTION OPTION -G G 1/2 B CONNECTION (MANOMETER) OPTION -V1 0.500-14 NPT CONNECTION WITH VENT SCREW Table 3. Parts for Figure 2 Item *1 Part No. Qty. Below 1 X0201LY X0118CC O-Ring, Housing Neck O-Ring, Standard X0144KW 2 Part Name O-Ring for use with CSA Certifications only; see WARNING A/R Lubricant PL 009-011 Page 9 PARTS 316L ss Sensor, Silicone Oil Fill, 316L ss Process Connection Part Number Reference Model Code Maximum Span D0185CA D0179RR D0179GW D0185CB D0179RS D0180HA IGP25-.22D IGP25-.22D..-G IGP25-.22D..-V1 IGP25-.22E IGP25-.22E..-G IGP25-.22E..-V1 1.4 MPa (200 psig) 1.4 MPa (200 psig) 1.4 MPa (200 psig) 14 MPa (2000 psig) 14 MPa (2000 psig) 14 MPa (2000 psig) 316L ss Sensor, Inert Oil Fill, 316L ss Process Connection Part Number Reference Model Code Maximum Span D0185CC D0179RT D0179HB D0185CD D0179RU D0179HC IGP25-.23D IGP25-.23D..-G IGP25-.23D..-V1 IGP25-.23E IGP25-.23E..-G IGP25-.23E..-V1 1.4 MPa (200 psig) 1.4 MPa (200 psig) 1.4 MPa (200 psig) 14 MPa (2000 psig) 14 MPa (2000 psig) 14 MPa (2000 psig) PL 009-011 Page 10 PARTS Figure 3. Flameproof Transmitter Replacement Sensor Assembly (See Figure 2 for Transmitter (not flameproof) Replacement Sensor Assemblies) (See Figure 4 for Replacement Sensor Assemblies for Transmitters with Sanitary or Pulp and Paper Process Connections) TYPICAL 2 1 ! WARNING Failure to install the proper Housing Neck O-Ring (Item 1) for CSA-labeled products violates ANSI/ISA 12.27.01 STANDARD 0.500-14 NPT CONNECTION OPTION -G G 1/2 B CONNECTION (MANOMETER) OPTION -V1 0.500-14 NPT CONNECTION WITH VENT SCREW Table 4. Parts for Figure 3 Item *1 2 Part No. Below Qty. 1 Part Name O-Ring, Housing Neck X0201LY O-Ring, Standard X0144KW O-Ring for use with CSA Certifications only; see WARNING X0118CC A/R Lubricant 316L ss Sensor, Silicone Oil Fill, 316L ss Process Connection Part Number Reference Model Code Maximum Span D0179RZ D0179VB D0179XK D0179SA D0179VC D0179XL IGP25-.52D IGP25-.52D..-G IGP25-.52D..-V1 IGP25-.52E IGP25-.52E..-G IGP25-.52E..-V1 1.4 MPa (200 psig) 1.4 MPa (200 psig) 1.4 MPa (200 psig) 14 MPa (2000 psig) 14 MPa (2000 psig) 14 MPa (2000 psig) PL 009-011 Page 11 PARTS 316L ss Sensor, Silicone Oil Fill, 316L ss Process Connection Part Number Reference Model Code Maximum Span D0179SB D0179VD D0179XM D0179SE D0179VE D0179XN IGP25-.53D IGP25-.53D..-G IGP25-.53D..-V1 IGP25-.53E IGP25-.53E..-G IGP25-.53E..-V1 1.4 MPa (200 psig) 1.4 MPa (200 psig) 1.4 MPa (200 psig) 14 MPa (2000 psig) 14 MPa (2000 psig) 14 MPa (2000 psig) Figure 4. Replacement Sensor Assemblies for Transmitters with Sanitary or Pulp and Paper Process Connections (See Figure 2 for Transmitter Replacement Sensor Assemblies - not Flameproof) (See Figure 3 for Flameproof Transmitter Replacement Sensor Assemblies) IGP25 REPLACEMENT SENSOR ASSEMBLIES - SPAN LIMIT CODE D VENT TUBE TO MEMBRANE PLUG ON HOUSING. SEE BELOW. SANITARY PULP/PAPER PULP/PAPER SANITARY IGP25 REPLACEMENT SENSOR ASSEMBLIES - SPAN LIMIT CODE E (ONLY AVAILABLE WITH SANITARY STRUCTURES TA, TB, AND T2 TO T5) SANITARY SANITARY PL 009-011 Page 12 PARTS IGP25 Sanitary and Pulp/Paper Transmitters - Configurations Offered (a) Span Limit Code Used with Sanitary Structure Codes Used with Pulp/Paper Structure Codes D All Sanitary Structure Codes E TA, TB, and T2 to T5 only (b) All Pulp/Paper Structure Codes Not available Vent Tube to Membrane Breather Plug on Housing Used with Sanitary and Pulp/Paper Transmitters. Vent Tube not required; no breather plug in housing. a. Also refer to “Model Code” on page 3. b. When used with Span Limit Code E, limit is 4.2 MPa (600 psi), or the rating of the Tri-Clamp type connector used, whichever is less. NOTE Seals provided with all IGP25 Sanitary Transmitter Structure Codes have a seal surface finish of 32 Ra. Seals with IGP25 Sanitary Transmitter Structure Codes TA, TB, T2 to T5, M1, M6, and M9 can be provided with a seal surface finish of 15 Ra when Option -F1 is selected. IGP25 Transmitters - Pulp and Paper Process Connections Replacement Sensor Assemblies - 316L ss Process Connection; Silicone Fill Reference IGP25 Model Number Part Number Diaphragm Material Maximum Span IGP25-.PAD IGP25-.PBD IGP25-.PCD IGP25-.PDD IGP25-.PED IGP25-.PFD IGP25-.PGD IGP25-.PHD IGP25-.PJD D0186TV D0186TX D0186TZ D0186UB D0186UD D0186UF D0186UH D0186UK D0186UM 316L ss 316L ss 316L ss 316L ss Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) 1.4 MPa (200 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) a. Equivalent to Hastelloy C. PL 009-011 Page 13 PARTS IGP25 Transmitters - Sanitary Process Connections - Seal Surface Finish is 32 Ra. Replacement Sensor Assemblies - 316L ss Process Connection; NEOBEE M-20 Fill Reference IGP25 Model Number Part Number Diaphragm Material Maximum Span IGP25-.TAD IGP25-.TAE IGP25-.T2D IGP25-.T2E IGP25-.T3D IGP25-.T3E IGP25-.TBD IGP25-.TBE IGP25-.T4D IGP25-.T4E IGP25-.T5D IGP25-.T5E IGP25-.M1D IGP25-.M6D IGP25-.M9D D0186TA D0186TB D0186TC D0186TD D0186TE D0186TF D0186TG D0186TH D0186TJ D0186TK D0186TL D0186TM D0186TN D0186TP D0186TQ 316L ss 316L ss 316L ss 316L ss 316L ss 316L ss Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) 316L ss 316L ss 316L ss 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) a. Equivalent to Hastelloy C. IGP25 Transmitters - Sanitary Process Connections - Seal Surface Finish is 15 Ra. Replacement Sensor Assemblies - 316L ss Process Connection; NEOBEE M-20 Fill Reference IGP25 Model Number Part Number Diaphragm Material Maximum Span IGP25-.TAD..-F1 IGP25-.TAE..-F1 IGP25-.T2D..-F1 IGP25-.T2E..-F1 IGP25-.T3D..-F1 IGP25-.T3E..-F1 IGP25-.TBD..-F1 IGP25-.TBE..-F1 IGP25-.T4D..-F1 IGP25-.T4E..-F1 IGP25-.T5D..-F1 IGP25-.T5E..-F1 IGP25-.M1D..-F1 IGP25-.M6D..-F1 IGP25-.M9D..-F1 D0197LG D0197LH D0197LJ D0197LK D0197LL D0197LM D0197LN D0197LP D0197LQ D0197LR D0197LS D0197LT D0197LU D0197LV D0197LW 316L ss 316L ss 316L ss 316L ss 316L ss 316L ss Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) Nickel alloy (a) 316L ss 316L ss 316L ss 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 4.2 MPa (600 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) 1.4 MPa (200 psi) a. Equivalent to Hastelloy C. PL 009-011 Page 14 PARTS ! CAUTION The IGP25 replacement sensors with Span Limit Code D listed above are for use with electronics housings having a membrane breather plug. These replacement sensors are distinguishable by the vent tube shown in Figure 4. Conversely, housings that do not have a membrane breather plug must be used with sensor assemblies not having a vent tube. For users with an existing IGP25 transmitter with Span Limit Code D, not having a housing with a membrane breather plug, and that require a replacement sensor assembly, contact Global Customer Support for a replacement housing assembly with a membrane breather plug. Figure 5. Optional Liquid Crystal Display (LCD) Digital Indicator Assembly Optional Selection -L1 5 3 2 1 4 Table 5. Parts for Figure 5 Item 1 *2 3 4 5 Part No. Below Qty. 1 Part Name Cover Assembly with Window - used with LCD Indicator D0162LH Aluminum Cover Assembly D0162VH Stainless Steel Cover Assembly D0162LQ 1 X0118CC A/R P0177HB 1 0048130 A/R Indicator Module Grease, Lubriplate (1-3/4 ounce tube) Indicator Cable Grease, Silicone (150 gram tube) PL 009-011 Page 15 PARTS Figure 6. Optional Custody Transfer Lock and Seal Optional Selection -Z2 2 3 3 4 2 1 Table 6. Parts for Figure 6 Item 1 2 3 4 Part No. Qty. Part Name S001806 2 Lead Seal D0162WM 2 Screw, Lock, 0.164-32 X0118CC A/R Grease, Lubriplate (1-3/4 ounce tube) S001807 A/R Sealing Wire Figure 7. Optional Metric Process Connection (Available with Structure Codes 22, 23, D1, and D2 only) Optional Selection -R DIRECT CONNECTED TRANSMITTER (REFERENCE) 1 Table 7. Parts for Figure 7 Item 1 Part No. X0171ZX Qty. 1 Part Name Adapter, Pipe, 316 ss, 1/2 NPT to R 1/2 PL 009-011 Page 16 PARTS Figure 8. Optional Block and Bleed Valve (Available with Structure Codes 22, 23, D1, and D2 only) Optional Selection -V2, -V3, or -V4 DIRECT CONNECTED TRANSMITTER (REFERENCE) 1 Table 8. Parts for Figure 8 Item 1 Part No. Below X0172BU X0172BV X0172BW Qty. 1 Part Name Block and Bleed Valve Carbon Steel (Optional Selection -V2) 316 ss (Optional Selection -V3) 316 ss Body, Monel Trim, NACE Approved (Optional Selection -V4) Figure 9. Optional Vent Screw Optional Selection -V1 1 DIRECT CONNECTED TRANSMITTER (REFERENCE) Table 9. Parts for Figure 9 Item 1 Part No. D0161SW Qty. 1 Part Name Vent Screw, 316 ss PL 009-011 Page 17 PARTS Figure 10. Optional Conduit-Connections Optional Selections -A1, -A2, -A3, and -A4 1 HAWKE-TYPE CABLE GLAND (1/2 NPT) NYLON CABLE GLAND (PG 13.5) 2 CABLE GLAND CABLE GLAND 1/2 NPT 3 1/2 NPT PG 13.5 BRASS CABLE GLAND (PG 13.5) CABLE GLAND M20 (-A1) 4 M20 CONDUIT CONNECTION (1/2 NPT) (-A2) PG 13.5 (-A3) Table 10. Parts for Figure 10 Item 1 2 3 4 Part No. Qty. N7141HX X0178GU N7141DX N7141DW 1 1 1 1 Part Name Hawke-Type Cable Gland (for 1/2 NPT) Nylon Cable Gland (for PG 13.5) Metric Conduit Thread Connection, M20/20 mm (for 1/2 NPT) Plated Brass Cable Gland (for PG 13.5) Figure 11. Optional Pipe Mounting Sets Optional Selection -M1, -M2, -M3, -M4, -M5, and -M6 (See NOTE) 5 4 VERTICAL PIPE MOUNTING NOTE 1 3 2 HORIZONTAL PIPE MOUNTING FOR FLAMEPROOF TRANSMITTERS, REFER TO FIGURE 12. (-A4) PL 009-011 Page 18 PARTS Table 11. Parts for Figure 11 Optional Selections -M1, -M3, and -M5 (Painted Steel) Item Part No. Qty. Part Name – Below B0188DL D0166AP D0179FN – Mounting Bracket Set; Options -M1, -M3, and -M5 Option -M1, Aluminum Housing; 1/2 NPT Connections Option -M3, Aluminum Housing; PG 13.5 Connections Option -M5, Aluminum Housing; M20 Connections 1 2 3 N0141ZW D0114SM 0011962 1 1 2 Bracket, Mounting, painted steel U-Bolt, Steel Nut, Hex Head, plated cs, 0.312-18 4 Below B0188DN D0166AM D0179FM 1 Adapter Plug 1/2 NPT to 0.375-24, ss, Option -M1 PG 13.5 to 0.375-24, ss, Option -M3 M20 to 0.375-24, ss, Option -M5 5 X0116FB 1 Screw, Hex Head, plated cs, 0.375-24 x 0.625 Optional Selection -M2, -M4, and -M6 (Stainless Steel) Item Part No. Qty. Part Name – Below N1207AE D0166AN D0179FP – Mounting Bracket Set; Options -M2, -M4, and -M6 Option -M2, 316 ss Housing; 1/2 NPT Connections Option -M4, 316 ss Housing; PG 13.5 Connections Option -M6, 316 ss Housing; M20 Connections 1 2 3 N1205MF N1205MX Z1217HV 1 1 2 Bracket, Mounting, stainless steel U-Bolt, stainless steel Nut, Hex Head, ss, 0.312-18 4 Below B0188DN D0166AM D0179FM P0120RM 1 Adapter Plug 1/2 NPT to 0.375-24, ss, Option -M2 PG 13.5 to 0.375-24, ss, Option -M4 M20 to 0.375-24, ss, Option -M6 Screw, Hex Head, ss, 0.375-24 x 0.625 5 1 PL 009-011 Page 19 PARTS Figure 12. Optional Pipe Mounting Sets Optional Selections -M1 to -M6 for Use with Flameproof Transmitters FLAMEPROOF TRANSMITTER WITH OPTIONS -M1 TO -M6 1 2 4 5 3 Table 12. Parts for Table 12 Optional Selections -M1 to -M6 (Refer to Figure 11 for part numbers of Items 1 to 5) Item Part No. Qty. Part Name – Below B0188DL D0166AP D0179FN 1 Mounting Bracket Set; Painted Steel; Options -M1, -M3, and -M5 Option -M1, Aluminum Housing; 1/2 NPT Connections Option -M3, Aluminum Housing; PG 13.5 Connections Option -M5, Aluminum Housing; M20 Connections – Below N1207AE D0166AN D0179FP 1 Mounting Bracket Set; Stainless Steel; Options -M2, -M4, and -M6 Option -M2, 316 ss Housing; 1/2 NPT Connections Option -M4, 316 ss Housing; PG 13.5 Connections Option -M6, 316 ss Housing; M20 Connections PL 009-011 Page 20 PARTS Figure 13. Pressure Seals for Use with IGP25 Transmitters (Page 1) NOTE The pressure seals shown below are used with IGP25 Transmitters. Pressure seals are not replaceable items; they must be replaced with the entire transmitter/seal assembly. In this case, both transmitter and pressure seal Model Numbers must be used for the assembled transmitter/seal system. Refer to data plates attached to transmitter and pressure seal(s) for applicable part numbers, or refer to PSS 2A-1Z11 A for Pressure Seal Model Codes. FIELD TERMINALS MODEL PSISR RECESSED DIAPHRAGM-IN-LINE SADDLE WELD REMOTE MOUNT SEAL CAPILLARY CONNECTION WELDED TO TRANSMITTER EIGHT BOLTS FOR ATTACHING UPPER HOUSING TO LOWER HOUSING EIGHT BOLTS FOR ATTACHING UPPER HOUSING TO LOWER HOUSING 4-INCH PROCESS PIPE AND LARGER IN-LINE SADDLE WELD THE LOWER HOUSING TO PROCESS PIPE PRIOR TO ASSEMBLING UPPER HOUSING TO LOWER HOUSING. 3-INCH (BUT LESS THAN 4-INCH) PROCESS PIPE. FIELD TERMINALS MODEL PSSSR SANITARY, DIRECT CONNECT TO STANDARD OR MINI SPUD REMOTE MOUNT SEAL CAPILLARY CONNECTION WELDED TO TRANSMITTER CAPILLARY CONNECTION WELDED TO SEAL TRI-CLAMP CONNECTION SPUD EXTENSION VARIES WITH SPUD SIZE PL 009-011 Page 21 PARTS Figure 14. Pressure Seals for Use with IGP25 Transmitters (Page 2) MODEL PSFAR RECESSED DIAPHRAGM-FLANGED CONNECTION REMOTE MOUNT SEALS FIELD TERMINALS FIELD TERMINALS MODELS PSFPS AND PSFES FLUSH DIAPHRAGM-FLANGED CONNECTION REMOTE MOUNT SEALS CAPILLARY CONNECTION WELDED TO TRANSMITTER PSFPS HAS FLUSH DIAPHRAGM PSFES HAS EXTENDED FLUSH DIAPHRAGM CAPILLARY CONNECTION WELDED TO TRANSMITTER USER SUPPLIED FLANGE BOLTS CONNECT TO PROCESS FLANGE WHEN SEAL HAS A 2.4 OR 3.0 INCH DIAPHRAGM FOUR STUDS FOR CONNECTION TO PROCESS FLANGE WHEN SEAL HAS A 4.0 INCH DIAPHRAGM FIELD TERMINALS CAPILLARY CONNECTION WELDED TO TRANSMITTER MODEL PSSCR FLUSH DIAPHRAGM SANITARY TRI-CLAMP REMOTE MOUNT SEAL FIELD TERMINALS MODEL PSTAR RECESSED DIAPHRAGM THREADED CONNECTION REMOTE MOUNT SEAL CAPILLARY CONNECTION WELDED TO TRANSMITTER USER-SUPPLIED O-RING AND TRI-CLAMP (REFERENCE) SIX BOLTS FOR ATTACHING UPPER HOUSING TO LOWER HOUSING 3.0 OR 4.0 in. DIAPHRAGM INTERNALLY THREADED NPT PROCESS CONNECTION PROCESS PIPE (REFERENCE) PL 009-011 Page 22 PARTS Figure 15. Pressure Seals for Use with IGP25 Transmitters (Page 3) FIELD TERMINALS FIELD TERMINALS FIELD TERMINALS MODELS PSFAD, PSTAD, AND PSISD DIRECT CONNECT SEALS 1/2 NPT CONNECTION 1/2 NPT CONNECTION 1/2 NPT CONNECTION PSFAD BOLT MOUNT PSTAD THREADED CONNECTION FIELD TERMINALS FIELD TERMINALS PSFAD STUD MOUNT 1/2 NPT CONNECTION 1/2 NPT CONNECTION PSISD 3-INCH PIPE PSISD 4-INCH PIPE PL 009-011 Page 23 PARTS Figure 16. Integral Sanitary Process Connectors for Use with IGP25 Transmitters NOTE The integral sanitary process connectors shown below are used with IGP25 Transmitters. Refer to Figure 4 for replacement sensor assemblies, and to pages that follow for accessories used with these transmitters. TRANSMITTER WITH INTEGRAL SANITARY TRI-CLAMP PROCESS CONNECTOR MEMBRANE BREATHER PLUG, TYPICAL. TRANSMITTER WITH INTEGRAL MINI TANK SPUD SEAL TRI-CLAMP CONNECTOR STRUCTURE CODES TA, T2, T3, TB, T4, T5 STRUCTURE CODES M1, M6, M9 OPTIONAL EXTERNAL ZERO ADJUSTMENT 2 1/2 in TRI-CLAMP 1 1/2 , 2, OR 3 in TRI-CLAMP 1 1/2, 6, OR 9 in EXTENSION Table 13. Parts for Figure 16 Item 1 Part No. Qty. 1 D0186DR Part Number Membrane Breather Plug (for use with Span Limit Code D only) Accessories Configuration of Mini Tank Spuds, Weld Spuds, Heat Sinks/Plugs, and Calibration Adapters MINI TANK SPUDS MINI TANK SPUDS 3.047 3.047 2.135 2.135 Spud Extension Structure Spud Extension Structure Part No. A Code Code Part No. A 1.50 A A N1212GG N1212GG 1.50 N1214BP 6.00 6.00 N1214BP N1214BQ 9.00 9.00 N1214BQ 2.155 2.155 3.73 3.73 M1 M6 M9 M1 M6 M9 PL 009-011 Page 24 PARTS Table 14. Tri-Clamp Type Connector Part Numbers (a) Nominal Tube O.D. MWP at 70°F MWP at 250°F Part Number 1.5 in Tube 2 in Tube 3 in Tube 1.5 in Tube 2 in Tube 2.5 in Tube 3 in Tube 4 in Tube 1.5 in Tube 2 in Tube 4 in Tube 500 psi 450 psi 350 psi 600 psi 550 psi 450 psi 350 psi 300 psi 1500 psi 1000 psi 800 psi 300 psi 300 psi 195 psi 300 psi 275 psi 225 psi 175 psi 150 psi 1200 psi 800 psi 600 psi N1212DA N1212DB N1212DC N1212PP N1212PQ N1212HG (b) N1212PR N1212PS N1212FV N1212FW N1212AW a. Tri-Clamps are generally supplied by user but can be ordered from Global Customer Support. b. The Foxboro N1212HG Tri-Clamp Type Connector for a 2.5 in tube is used with Mini Tank Spud Connectors M1, M6, and M9. Table 15. Package of O-ring Supplied by Foxboro (a) Structure Code M1, M6, M9 Description O-Rings Application For use with Mini Tank Spud Connector Part Number N1212LB a. Part number is for a package of five O-rings. Each transmitter is shipped with its required O-rings. This package of O-rings is recommended extras or spares. PL 009-011 Page 25 PARTS Figure 17. Integral Pulp and Paper Process Connectors for Use with IGP25 Transmitters. NOTE The integral pulp and paper process connectors shown below are used with IGP25 Transmitters. Refer to Figure 4 for replacement sensor assemblies, and to pages that follow for accessories used with these transmitters. TRANSMITTER WITH INTEGRAL PULP AND PAPER THREADED TYPE CONNECTOR TRANSMITTER WITH INTEGRAL PULP AND PAPER SLEEVE TYPE CONNECTOR MEMBRANE BREATHER PLUG, TYPICAL. 1 (TYPICAL) OPTIONAL EXTERNAL ZERO ADJUSTMENT. HEX HEAD 1 inch SLEEVE TYPE HEX HEAD 1 3/12 - 20 OR M44 x 1.25 OR 1 1/2 -18 O-RING GROOVES WELD SPUD WELD SPUD TAPERED HEAD 1 1/2 inch SLEEVE TYPE WELD SPUD VESSEL WALL WELD VESSEL WALL WELD O-RING GASKET Table 16. Parts for Figure 17 Item 1 Part No. D0186DR Qty. 1 Part Number Membrane Breather Plug (for use with Span Limit Code D only) PL 009-011 Page 26 PARTS Configuration of Weld Spuds, Heat Sinks/Plugs, and Calibration Adapters WELD SPUD - N1214MM (a) WELD SPUD - N1214LH (a) 0.32 DIA. TWO PLACES 1.02 1.00 1.59 1.05 1.90 1.315 (a) Used with Structure Codes PC, PG (a) Used with Structure Codes PA, PE C WELD SPUDS Part No. (a) N1214XW N1214LG N1216AM B B Thread C 1.50 2.12 1.99 0.80 0.80 1.00 1 3/32-20 M44 x 1.25 1 1/2-18 Struct. Code PB, PF PD, PH PJ a. Must be used with heat sinks/plugs below to prevent metal distortion due to high temperature of welding process. A HEAT SINKS/PLUGS A A Part No. (a) 0.28 C 1.15 0.40 N1214Y N1214YR N1216AP A B Thread C 1.125 1.75 1.75 1.000 1.595 1.595 1 3/32 - 20 M44 x 1.25 1 1/2-18 Struct. Code PB, PF PD, PH PJ a. Must be used with weld spuds above to prevent metal distortion due to high temperature of welding process. B THREADED-TYPE CALIBRATION ADAPTERS C Part No. B N1214XX N1216AN (a) A B 1.50 1.99 1.50 1.75 Thread C 1 3/32-20 1 1/2-18 Struct. Code PB, PF PJ a. For Ametak spud. 1/4 NPT A SLEEVE-TYPE CALIBRATION ADAPTERS THREADED-TYPE CALIBRATION ADAPTER - N1214MN (a) A B WRENCH FLATS 1.05 1/4 NPT 2.20 0.28 1.50 C Part No. A B C 1/4 NPT Struct. Code N1214MG 1.90 1.60 1.62 PA, PE N1216MP 1.315 1.05 1.05 PC, PG 0.76 M44 x 1.25 2.12 (a) Used with Structure Codes PD, PH PL 009-011 Page 27 PARTS Accessories Table 17. Weld Spuds, Calibration Adapters, Heat Sinks/Plugs, O-Rings, and Gaskets used with Threaded and Sleeve Type Process Connectors Description of Accessory (a) For use with 1-inch Sleeve Type Connector Weld Spud Calibration Adapter Process O-Ring at Diaphragm (Viton), 1-in Sleeve Process O-Ring, Outer (Viton), 1-in Sleeve For use with 1-inch Flush, Threaded Type Connector Weld Spud (e) Heat Sink/Plug (e) Calibration Adapter Process Gasket (Gylon) For use with 1.5-inch Sleeve Type Connector Weld Spud Calibration Adapter Process O-Ring (Viton) For use with 1.5-inch Flush, Threaded Type Connector Weld Spud (e) Heat Sink/Plug (e) Calibration Adapter Process Gasket (Gylon) For use with 1.5-inch Threaded Type Connector for Ametek Spud Weld Spud (e) Heat Sink/Plug (e) Calibration Adapter Process Gasket (Gylon) a. b. c. d. Used with Structure Code Part Number (b) PA, PE PA, PE PA, PE PA, PE N1214LH (c) N1214MP (c) N1214YY (d) N1214YZ (d) PB, PF PB, PF PB, PF PB, PF N1214XW (c) N1214YS (c) N1214XX (d) N1214YX (d) PC, PG PC, PG PC, PG N1214MM (c) N1214MQ (c) N1214YW (d) PD, PH PD, PH PD, PH PD, PH N1214LG (c) N1214YR (c) N1214MN (c) N1214YV (d) PJ PJ PJ PJ N1216AM N1216AP N1216AN N1216AQ (d) Accessories are ordered and supplied separately. Refer to Figure 17 for configuration and dimensions of certain accessories listed. Weld spuds, heat sinks/plugs, and calibration adapters are supplied by user. Each transmitter is shipped with its required gaskets or O-rings. Part number is for a package of five O-rings or gaskets. The gaskets and O-rings listed are offered as extras (spares). e. When ordering a weld spud for use with a threaded type connector, note that use of a heat sink/plug is required to prevent metal distortion due to the high temperature of the welding process. PL 009-011 Page 28 RECOMMENDED SPARE PARTS SUMMARY Recommended Spare Parts Summary Number of Parts Recommended for Figure Number Item Number Figure 1 3 10 Part Number X0201FC Below D0162UJ D0162UL D0162UN O-Ring, Cover Electronics Module Digital FoxCom or 4 to 20 mA (Code –D) Digital HART and 4 to 20 mA (Code –T) Digital FOUNDATION Fieldbus (Code –F) Transmitter Sensor Assembly 12 Reference Model Code (Also see Below IGP25-.22D Figure 2) D0185CA IGP25-.22D..-G D0179RR IGP25-.22D..-V1 D0179GW IGP25-.22E D0185CB IGP25-.22E..-G D0179RS IGP25-.22E..-V1 D0180HA D0185CC D0179RT D0179HB D0185CD D0179RU D0179HC 13 (Also see Below Figure 3) D0179RZ D0179VB D0179XK D0179SA D0179VC D0179XL D0179SB D0179VD D0179XM D0179SE D0179VE D0179XN Figure 1 Part Name 12 (Also see Below Figure 4) D0186TA D0186TB D0186TC D0186TD D0186TE D0186TF D0186TG D0186TH D0186TJ D0186TK D0186TL D0186TM D0186TN D0186TP D0186TQ IGP25-.23D IGP25-.23D..-G IGP25-.23D..-V1 IGP25-.23E IGP25-.23E..-G IGP25-.23E..-V1 Flameproof Transmitter Sensor Assembly Reference Model Code IGP25-.52D IGP25-.52D..-G IGP25-.52D..-V1 IGP25-.52E IGP25-.52E..-G IGP25-.52E..-V1 IGP25-.53D IGP25-.53D..-G IGP25-.53D..-V1 IGP25-.53E IGP25-.53E..-G IGP25-.53E..-V1 IGP25 Sanitary Transmitter Sensor Assembly (Reference Model Code) IGP25-.TAD IGP25-.TAE IGP25-.T2D IGP25-.T2E IGP25-.T3D SEAL IGP25-.T3E SURFACE IGP25-.TBD FINISH IGP25-.TBE IS IGP25-.T4D 32 Ra IGP25-.T4E IGP25-.T5D IGP25-.T5E IGP25-.M1D IGP25-.M6D IGP25-.M9D 1 Inst. 5 Inst. 20 Inst. 0 0 2 1 4 1 0 1 1 0 1 1 0 1 1 PL 009-011 Page 29 RECOMMENDED SPARE PARTS SUMMARY Recommended Spare Parts Summary (Continued) Number of Parts Recommended for Figure Number Item Number Figure 1 12 (Also see Below Figure 4) D0197LG D0197LH D0197LJ D0197LK D0197LL D0197LM D0197LN D0197LP D0197LQ D0197LR D0197LS D0197LT D0197LU D0197LV D0197LW 12 (Also see Below Figure 4) D0186TV D0186TX D0186TZ D0186UB D0186UD D0186UF D0186UH D0186UK D0186UM 1 Below X0201LY X0144KW 1 Below X0201LY X0144KW 2 D0162LQ 1 D0186DR (a) 1 D0186DR (a) Figure 1 Figure 2 Figure 3 Figure 5 Figure 16 Figure 17 Part Number Part Name IGP25 Sanitary Transmitter Sensor Assembly (Reference Model Code) IGP25-.TAD..-F IGP25-.TAE..-F IGP25-.T2D..-F IGP25-.T2E..-F IGP25-.T3D..-F IGP25-.T3E..-F IGP25-.TBD..-F SEAL IGP25-.TBE..-F SURFACE IGP25-.T4D..-F FINISH IGP25-.T4E..-F IS IGP25-.T5D..-F 15 Ra IGP25-.T5E..-F IGP25-.M1D..-F IGP25-.M6D..-F IGP25-.M9D..-F IGP25 Pulp/Paper Transmitter Sensor Assy (Reference Model Code) IGP25-.PAD IGP25-.PBD IGP25-.PCD IGP25-.PDD IGP25-.PED IGP25-.PFD IGP25-.PGD IGP25-.PHH IGP25-.PJD O-Ring, Housing Neck Standard For use with CSA Certifications only. O-Ring, Housing Neck Standard For use with CSA Certifications only. LCD Indicator Module Plug, Membrane Breather Plug, Membrane Breather 1 Inst. 5 Inst. 20 Inst. 0 1 1 0 1 1 1 2 4 1 2 4 0 0 0 1 2 2 1 4 4 a. Breather plugs are only used with Sanitary and Pulp and Paper process connections having Span Limit Code D. PL 009-011 Page 30 RECOMMENDED ACCESSORIES FOR USE WITH INTEGRAL SANITARY PROCESS CONNECTORS Recommended Accessories for Use With Integral Sanitary Process Connectors Number of Parts Recommended for Figure Number Table Number Part Number - Table 15 Below N1212LB Part Name O-Rings (a) O-Ring; used with Mini Tank Spud 1 Inst. 5 Inst. 20 Inst. 1 2 4 a. Part number is for a package of five O-rings. Although each transmitter is shipped with its required O-rings, additional O-rings are recommended as spares. Recommended Accessories for Use With Integral Pulp and Paper Process Connectors Number of Parts Recommended for Figure Table Number Number - Part Number Part Name O-Rings and Gaskets (a) Table 17 Below Process O-ring at Diaphragm; 1-in Sleeve N1214YY Process O-ring outer; 1-in Sleeve N1214YZ Process Gasket; 1-in Threaded N1214YX Process O-ring; 1.5-in Sleeve N1214YW Process Gasket; 1.5-in Threaded N1214YV Process Gasket; 1.5 in Threaded N1216AQ for Ametek Spud 1 Inst. 5 Inst. 20 Inst. 1 2 4 a. Part number is for a package of five O-rings or gaskets. Although each transmitter is shipped with its required O-rings or gaskets, additional O-rings and gaskets are recommended as spares. PL 009-011 Page 31 NOTES Notes PL 009-011 Page 32 Invensys Systems, Inc. 10900 Equity Drive Houston, TX 77041 United States of America http://www.invensys.com Global Customer Support Inside U.S.: 1-866-746-6477 Outside U.S.: 1-508-549-2424 Website: http://support.ips.invensys.com Copyright 2002-2015 Invensys Systems, Inc. All rights reserved. Invensys, Foxboro, FoxCom, and I/A Series are trademarks of Invensys Limited, its subsidiaries, and affiliates. All other trademarks are the property of their respective owners. Invensys is now part of Schneider Electric. 0415