[PL 009-166] 740R Series Digital Circular Chart Recorder
Transcription
[PL 009-166] 740R Series Digital Circular Chart Recorder
Parts List PL 009-166 April 2015 740R Series Digital Circular Chart Recorder and 740C Series Digital Circular Chart and Recording Controller — Style AA Give instrument Model Code when ordering. *Parts preceded by an asterisk are recommended spare parts. See Recommended Spare Parts Summary section for quantities. TO ORDER PARTS, CALL 1-866-746-6477. PL 009-166 Page 2 MODEL CODE - 740RA DIGITAL CIRCULAR CHART RECORDER Model Code - 740RA Digital Circular Chart Recorder Description Digital, Circular Chart Recorder Nominal Supply Voltage and Frequency 120 V ac, 50/60 Hz 240 V ac, 50/60 Hz Model 740RA –A –C Input Channel 1 (a) 0 to 20 mV dc through 0 to 5 V dc, with Pens, RTD and TC (b) 4 to 20 mA dc, with Pens (b) 1 3 Input Channel 2 Selection (a) None 0 to 20 mV dc through 0 to 5 V dc, with Pens, RTD and TC (b) 4 to 20 mA dc, with Pens (b) Greater than 0 to 5 V dc through 0 to 100 V dc, without Pens (b) 0 1 3 7 Input Channel 3 Selection (a) None 0 to 20 mV dc through 0 to 5 V dc, with Pens, RTD and TC (b) 4 to 20 mA dc, with Pens (b) 0 1 3 Input Channel 4 Selection (a) None 0 to 20 mV dc through 0 to 5 V dc, with Pens, RTD and TC (b) 4 to 20 mA dc, with Pens (b) 0 1 3 Optional Selections 28 V dc Transmitter Power Supply Calculated Variables and Custom Curve –A –B Select one option below only: One Integral Totalizer (One input Channel) Two Integral Totalizer (Two Input Channels) Three Integral Totalizers (Three Input Channels) Four Integral Totalizers (Four Input Channels) Dual Ramp Generators Tamper Evident Feature –C –D –E –F –G –K Select one option below only: NEMA 4X Enclosure (c) Polycarbonate Door Windows Pipe Mounting (NEMA 4X) (c) –L –M –N Select one option below only: (d) Two Relay Outputs Four Relay Output Six Relay Outputs Eight Relay Outputs –Q –R –S –T Select one option below only: (d) Eight Contact Inputs Sixteen Contact Inputs –U –V Select one option below only: One Remote Totalizer Output (e) (f) Two Remote Totalizer Outputs (e) (f) Three Remote Totalizer Outputs (e) (g) Four Remote Totalizer Outputs (e) (g) –1 –2 –3 –4 Select one option below only: (d) One 4 to 20 mA Retransmission Output Two 4 to 20 mA Retransmission Outputs Three 4 to 20 mA Retransmission Outputs Four 4 to 20 mA Retransmission Outputs –5 –6 –7 –8 Examples: 740RA-A1110; 740RA-C1113-BK; 740RA-A1100-LDR2 a. Input channels must be specified sequentially. Specify Input Code 0 if previous channel selection is Code 0. b. Operating ranges are field configurable. PL 009-166 Page 3 ELECTRICAL SAFETY SPECIFICATIONS c. NEMA 4X is standard with pipe mounting Code –N. d. The availability of Relay Output, Contact Input, and Retransmission Output Options is space dependent and therefore contingent upon previously selected functions. The instrument accommodates a maximum of three function PWAs with each PWA loaded as shown in Table 2. e. A totalizer must be selected for each totalizer output selected. f. Includes two relay outputs; maximum eight relay outputs. g. Includes four relay outputs; maximum eight relay outputs. Table 1. PWA Functions and Capacity Number of PWA’s Required 1 1 1 1 Selected Function One or two 4 to 20 mA Retransmission Outputs Two or Four Relay Outputs Eight Contact Inputs plus One or Two 4 to 20 mA Retransmission Outputs Eight Contact Inputs Electrical Safety Specifications Testing Laboratory, Type of Protection, and Area Classification CUL certified for use in General Purpose, Ordinary Locations CUL certified nonincendive, Ex n, Zone 2, Division 2 locations Electrical Certification Specification CS-E/CUL1 CS-E/CUL2 NOTE Electrical Safety Specifications also apply to 740CA Digital Circular Chart Recording Controller that follows. PL 009-166 Page 4 MODEL CODE - 740CA DIGITAL CIRCULAR CHART RECORDING CONTROLLER Model Code - 740CA Digital Circular Chart Recording Controller Description Digital, Circular Chart Recording Controller Nominal Supply Voltage and Frequency 120 V ac, 50/60 Hz 240 V ac, 50/60 Hz Model 740CA –A –C Input Channel 1 0 to 20 mV dc through 0 to 5 V dc, with Pens, RTD and TC (a) 4 to 20 mA dc, with Pens (a) 1 3 Input Channel 2 None 0 to 20 mV dc through 0 to 5 V dc, with Pens, RTD and TC (a) 4 to 20 mA dc, with Pens (a) 0 1 3 Input Channel 3 (b) None 0 to 20 mV dc through 0 to 5 V dc, with Pens, RTD and TC (a) 4 to 20 mA dc, with Pens (a) 0 1 3 Input Channel 4 (b) None 0 to 20 mV dc through 0 to 5 V dc, with Pens, RTD and TC (a) 4 to 20 mA dc, with Pens (a) 0 1 3 Control Type One PID without EXACT Tuning One PID with EXACT Tuning Two PIDs without EXACT Tuning Two PIDs, one with EXACT Tuning Two PIDs, both with EXACT Tuning A B C D E Output Type (See Table 2) Single 4 to 20 mA Output for one Controller (not with Control Types C, D, and E) Duplex 4 to 20 mA Outputs for one Controller (not with Control Types C, D, and E) Two Single 4 to 20 mA Outputs for two Controllers (not with Control Types A and B) Two Duplex 4 to 20 mA Outputs for two Controllers (not with Control Types A and B) Single 4 to 20 mA Output for one Controller, and Duplex 4 to 20 mA Output for second Controller (not with Control Types A and B) Single Time Duration, Relay Output for one Controller Duplex Time Duration, Relay Outputs for One Controller Two Single Time Duration, Relay Outputs for two Controllers Two Duplex Time Duration Relay Outputs for two Controllers Single Time Duration, Relay Output for one Controller, and Duplex Time Duration, Relay Output for second Controller A B C D E F G H I J Optional Selections 28 V dc Transmitter Power Supply Calculated Variables and Custom Curve –A –B Select one option below only: One Integral Totalizer (One input Channel) Two Integral Totalizer (Two Input Channels) Three Integral Totalizers (Three Input Channels) Four Integral Totalizers (Four Input Channels) Dual Ramp Generators Tamper Evident Feature –C –D –E –F –G –K Select one option below only: NEMA 4X Enclosure (c) Polycarbonate Door Windows Pipe Mounting (NEMA 4X) (c) –L –M –N Select one option below only: (d) Two Relay Outputs Four Relay Output Six Relay Outputs –Q –R –S MODEL CODE - 740CA DIGITAL CIRCULAR CHART RECORDING CONTROLLER PL 009-166 Page 5 Model Code - 740CA Digital Circular Chart Recording Controller (Continued) Description Eight Relay Outputs Model –T Select one option below only: (d)) Eight Contact Inputs Sixteen Contact Inputs Select one option below only: One Remote Totalizer Output (e) Two Remote Totalizer Outputs (e) Three Remote Totalizer Outputs (e) Four Remote Totalizer Outputs (e) –U –V –1 –2 –3 –4 Select one option below only: (d) (f) One 4 to 20 mA Retransmission Output Two 4 to 20 mA Retransmission Outputs Three 4 to 20 mA Retransmission Outputs Four 4 to 20 mA Retransmission Outputs –5 –6 –7 –8 Examples: 740RA-A1110; 740RA-C1113-BK; 740RA-A1100-LDR2 a. b. c. d. Operating ranges are field configurable. Input channels must be specified sequentially. Specify Input Code 0 if previous channel selection is Code 0. NEMA 4X is standard with pipe mounting Code –N. The availability of Relay Output, Contact Input, and Retransmission Output Options is space dependent and therefore contingent upon previously selected functions. The instrument accommodates a maximum of three function PWAs with each PWA loaded as shown in Table 2 below. e. Input channels must be specified sequentially. Specify Input Code 0 if previous channel selection is Code 0. f. The availability of Relay Output, Contact Input, and Retransmission Output Options is space dependent and therefore contingent upon previously selected functions. The instrument accommodates a maximum of three function PWAs with each PWA loaded as shown in Table 2 below. . Table 2. PWA Functions and Capacity Number of PWAs Required Selected Function 1 1 1 1 1 1 One or Two Single 4 to 20 mA Control Outputs One or Two 4 to 20 mA Retransmission Outputs Each Duplex 4 to 20 mA Control Output Two or Four Relay Outputs Eight Contact Inputs plus One or Two Single 4 to 20 mA Control or Retransmission Outputs Eight Contact Inputs plus One Duplex 4 to 20 mA Control Output Table 3. 4 to 20 mA Outputs Output Type Code Maximum Number of Retransmission Outputs Output Type Code Maximum Number of Retransmission Outputs A B C 3 2 2 D E F through J 0 1 4 PL 009-166 Page 6 PARTS Parts Figure 1. Door and Front Platen Parts 4 3 2 PEN LIFTER ASSEMBLY (REFERENCE) PLATEN ASSEMBLY (REFERENCE) KEYPAD (REFERENCE) 1 7 8 5 6 PL 009-166 Page 7 PARTS Table 4. Parts for Figure 1 Item Part No. 1 2 B0195CL 3 Below 4 B0195EZ Qty. 1 1-4 1 Part Name Display PWA, Includes Motor Drive and Mounting Hardware Pen Arm Assembly with Screws Pouch of Two Pens L0122AR Red L0122BP Purple L0122CG Green L0122DB Blue Below 1 B0195DL Door Assembly (see Note 1) With Plastic Window B0195DP Plastic Window for Door Lock B0195DK Glass Window for Door Lock 5 B0195AJ 1 Door Lock and Key 6 B0195CE 1 Handle with Hole for Lock (see Note 2) 7 8 B1278MM 1 2 Latch Kit X0127GC Screw NOTES 1 To eliminate the chart window for nonrecording and indicate only applications, specify AS Reference Code DRS-B. 2 To add a door lock to a nonlocking door, specify AS Reference Code DRS-A. This option provides a key operated lock in the door handle. PL 009-166 Page 8 PARTS Figure 2. Platen Rear View 2 1 Table 5. Parts for Figure 2 Item 1 2 Part No. B0195CR B0195CV Qty. 1 1-4 Part Name Micro Switch (includes mounting hardware) Servo Assembly with Mounting Hardware; Channel 1 PL 009-166 Page 9 PARTS Figure 3. Case Parts 3 2 1 CASE (REFERENCE) 4 6 14 5 12 16 17 7 15 11 13 10 9 Table 6. Parts for Figure 3 Item Part No. Qty. 1 2 3 4 5 6 B0195AD B0195DU 1 1 1 1 1 1 7 B0195CZ 1-2 B0195CG B0195AM B0195AL B0195CK Part Name Door Stop Stud Door Stop (Stay) Door Stop Pin Bracket Main PWA (see Note 1) 28 V Power Supply (includes mounting hardware) Input PWA (includes mounting hardware); 2 inputs May also be used for 1 input 9 10 B0195ED B0195EE 1-4 1-4 Mini PWA 4 to 20 mA, for use with internal power supply Mini PWA 4 to 20 mA PL 009-166 Page 10 PARTS Table 6. Parts for Figure 3 (Continued) Item 11 Part No. Below Qty. 1-2 B0195DN L0125BT With 4 Relays (includes mounting hardware) May also be used for 2 relays 2 Channel Retransmission Output (see Note 2) May also be used for 1 Retransmission Output 8 Contact Input, 1 Retransmission (see Note 2) L0125BU 8 Contact Input, 2 Retransmission Output (see Note 2) L0125BR *12 Below 1 Fuse, Slow Blow B0195FH 1 A, 120 V (10 per Pak) B0195FG 500 mA, 240 V (10 per Pak) 13 B0195FF 14 Below 15 16 17 Part Name Option PWA (see Note 1) A/R 1 Jumper Fuse, Slow Blow B0195GH 100 mA, 120 V B0195GJ 63 mA, 240 V B0195FK B0195HY B0195GY 1 1 1 Power Plug Cable Input PWA to Main PWA Cable Option PWA to Main PWA NOTES 1 This PWA contains firmware which is feature dependent. When ordering this part or when adding new PWAs to an existing instrument, supply Model Code and Serial Number origin code. 2 These are specifically for units manufactured after September 2000, and are identified by Status Level D4 or higher or (CE) D4 and higher. Status is shown as the last characters on the Serial Number Tag. A/R = As Required. PL 009-166 Page 11 SUPPLIES (SEE TABLE 8) Figure 4. Surface/Panel Mounting Kit 1 2 Table 7. Parts for Figure 4 Item 1 2 Part No. B0195AV B0195CB Qty. 2 1 Part Name Gasket (2 per Pak) Surface/Panel Mounting Kit, NEMA 4X Supplies (see Table 8) Supplies Refer to Pens Figure 1, Item - Red, Purple, Green, and Blue Pens (Pouch of two) Charts Foxboro Chart and Dial Catalog 600 PL 009-166 Page 12 CONVERSION KITS Conversion Kits These kits are specifically assembled to provide the new desired functions in addition to the functions currently resident in the recorder. It is therefore necessary to provide the Model Number, the Serial Number, and the Electronic Identification Code with the conversion kit order. Note that specific kits are to be ordered depending on the date manufactured. If manufactured after September 2000, these kits are identified with (b). If manufactured before September 2000, these kits are identified with (c). Remaining kits are not affected by date manufactured. See Table 8. Table 8. Conversion Kits Part Numbers Purpose Mfd. after Sept. 2000 Mfd. before Sept. 2000 Not Affected by Date Input Channels Kits The following kits provide hardware and instructions for adding input channels without the pen drives. Recorders must be returned to the factory to increase the number of pens. For 4 to 20 mA inputs, shunt resistor assembly is also required. B0195ED To add either Channel No. 2 or Channel No. 4 or both Channels 2 and 3 or L0125DB 3 and 4 (dual input board. Optional Functions Kits The following kits provide hardware and instructions for adding optional functions. The option boards are located to the right of the input boards. Maximum number of option boards possible is three. If there is no option board presently in the recorder, an Option Cable must B0195GY (a) be installed to interconnect the option boards. Relay Outputs Kit To add either relays 3 & 4 or 7 & 8 or 1, 2, 3 or 5,6,7 & 8 (four relay board) L0125CD (b) L0125CK (c) 4 to 20 mA Outputs Kits L0125CM (c) Add output 2 or 4 (dual output board) L0125CF (b) To add output 1 and 2 or outputs 3 and 4 (dual output board). Order L0125CG (b) L0125CN (c) quantity of two to add both 1 and 2 and 3 and 4. Contact Inputs Kit To add 8 contact inputs (all on one board) Order quantity of two for 16 L0125BX (b) L0125CP inputs. Power Supply Kit To add 28 volt field transmitter power supply board (does not consume an L0125DC option board position) a. The option card cable (B0195GY), if not already present, MUST be ordered separately. This cable (B0195GY) is to be used only for units manufactured before September 2000 and is identified by Status Level D3 and lower or (CE) Status Level D3 and lower. Status is shown as the last character on Serial Number tag. b. Part Numbered Kits specifically for units manufactured after September 2000; identified by Status Level D4 or higher or (CE) Status Level D4 and higher. Status is shown as the last characters on the Serial Number Tag. Appropriate mounting hardware and option cable (if needed) is included with part numbered kits. c. Part Numbered Kits specifically for units manufactured before September 2000 and identified by Status Level D3 and lower or (CE) Status Level D3 and lower. Status is shown as the last characters on the Serial Number Tag. PL 009-166 Page 13 RECOMMENDED SPARE PARTS SUMMARY Recommended Spare Parts Summary Number of Parts Recommended for Figure Number Item Figure 3 12 14 Part No. Below B0195FH B0195FG Below B0195GH B0195GJ Part Name Fuse, Slow Blow 1 A, 120 V 500 mA, 240 V Fuse, Slow Blow 100 mA, 120 V 63 mA, 240 V 1 Inst. 5 Inst. 20 Inst. 2 6 12 2 6 12 PL 009-166 Page 14 Invensys Systems, Inc. 10900 Equity Drive Houston, TX 77041 United States of America http://www.invensys.com Global Customer Support Inside U.S.: 1-866-746-6477 Outside U.S.: 1-508-549-2424 Website: http://support.ips.invensys.com Copyright 1992-2015 Invensys Systems, Inc. All rights reserved. Invensys and Foxboro are trademarks of Invensys Limited, its subsidiaries, and affiliates. All other trademarks are the property of their respective owners. Invensys is now part of Schneider Electric. 0415