LED Light Engine for Spot and Downlighting
Key Features & Benefits
—— High efficacy LED module with
integrated driver offering up to
103 LPW
—— Cost reduction by omitting gearbox,
cable, cover glass, and simplified
assembly
—— Phase-cut dimmable down to 10%
—— Poke-in wire connectors for easy
installation
—— Integrated driver allows direct
connection to 120Vac
—— Available in both >80 and >90 CRI
—— Industry standard mounting hole
pattern allows for compatibility
with existing accessories in the
market and eliminates the need
for additional driver electronic
control gear
PrevaLED Core Pro AC LED light engines are highly efficient, 120Vac
integrated modules ideal for use in recessed downlights, accent and
track lighting. These modules are phase-cut dimmable down to 10%
and are available in multiple color temperatures in both 2000 and
3000 lumen packages. The form factor of the PrevaLED AC Core is
similar to Zhaga Book 3 making it easy to integrate into typical
luminaire form factors. In addition, the PrevaLED Core Pro AC offers
a comprehensive five year warranty.
—— Superior dimming performance with
no strobing and flickering
—— Long Life: up to 50,000 hours (L70)
minimizing maintenance frequency
—— 5 year warranty
—— Automatic thermal roll-back in case
of over temperature (>100°C)
increases the reliability of the
product and application
Product Offering
Item
Nominal Lumens
PrevaLED Core Pro AC
2000
PrevaLED Core Pro AC
3000
CRI
Color Temperature
90
2700K & 3000K
80
3500K & 4000K
903000K
80
3500K & 4000K
Application Information
Applications
Specifications and Certifications
—— Accent lighting
—— Area lighting
—— Recessed downlights
—— Track lighting
T he OSRAM PrevaLED Core Pro AC is UL8750 Recognized
for the US and Canada UL File E320662, Vol. 1
F CC Part 15 Class A
LED457R1 6-15
Specification Data
Catalog #
Type
Project
Comments
Prepared by
Ordering Information
Item
Number Ordering Abbreviation
74108
PL-CORE-PRO AC-PC-2000-927-120V
73400PL-CORE-PRO-AC-PC-2000-930-120V
73401PL-CORE-PRO-AC-PC-2000-835-120V
73402PL-CORE-PRO-AC-PC-2000-840-120V
73403PL-CORE-PRO-AC-PC-3000-930-120V
73404PL-CORE-PRO-AC-PC-3000-835-120V
73405PL-CORE-PRO-AC-PC-3000-840-120V
Input
Initial
Voltage Lumens (lm)
120Vac1750
120Vac1820
120Vac2000
120Vac2080
120Vac2600
120Vac2890
120Vac2960
Light Emitting
Surface (LES)
19
19
19
19
19
19
19
Beam
Angle
120
120
120
120
120
120
120
Color
Nominal
Temperature CRI
Wattage (W)
2700K
>9020
3000K
>9021
3500K
>8020
4000K
>8020
3000K
>9033
3500K
>8031.5
4000K
>8031.5
Note:
1. All data shown above are taken at Tc=65°C and input of 120Vac, 60Hz
2. L 70 B 50 of 50,000 hrs at Tc= 65°C
3. Color consistency of <4 SDCM
4. Minimum dimming is dependent on the dimmer used. A dimming of at least 10% is achieved using the compatibility list in the section on following page
Dimming4
<10%
<10%
<10%
<10%
<10%
<10%
<10%
LPW
87
87
100
103
79
92
94
Case Qty.
20
20
20
20
20
20
20
Ordering Guide
PL
- CORE
-AC - PC
- 2000
-
9
LED Module Family
Family category
AC Input
Phase-Cut
Lumen Output
CRI
®
PL = PrevaLED Dimmable
9 = >90
8 = >80
Minimum and Maximum Ratings
ParameterValues
Maximum temperature at TC 90°C (194°F)
Modulation at 120Hz
<40%
Operating voltage 108Vac - 132Vac
Ambient operating temperature
-20°C to 50°C
Storage temperature
-20°C to 65°C
Note: If at any point during operation, the Tc exceeds 90°C the thermal derating feature is activated and the power will roll back to less than 5% of the input power
0.58 (14.8)
Assembly Diagram
3.14 (80)
3.14 (80)
0.12 (3.3)
2 PLACES
0.58 (14.8)
3.14 (80)
0.12 (3.3)
2 PLACES
1.37 (35)
3.14 (80)
Dimensions: in.(mm)
Wiring Diagram
Phase-cut Dimmer
1.37 (35)
Line
Neutral
27
-
120V
Color Temperature
Input Current
27 = 2700K
120Vac
30 = 3000K
35 = 3500K
40 = 4000K
Dimmer Compatibility
BrandModel
LEVITON Sureslide 6615-P0W
LEVITON Decora Sureslide 6674-P0T
LEVITON Vizia+ VPM10-1LZ
LEVITON IllumaTech IPI06-1LZ
LUTRON D-600P
LUTRON DV-600P
LUTRON S-600P
LUTRON SCL-153P
LUTRON MACL-153M
LUTRON DVELV-303P
Assembly Information
1. Carefully attach the module to heat sink sandwiching appropriate thermal interface material (TIM) to adequately dissipate thermal power.
2. Refer to Application Guide (LED460) for detailed assembly information.
Safety Information
WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION.
TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER SUPPLIES
AND/OR MODULES.
Failure to install the power supplies and/or LED modules in accordance with the National Electric Code (NEC), all applicable Federal, State and local
electric codes as well as the specific Underwriter’s Laboratories (UL) safety standards for the installation, location and application may cause serious
personal injury, death, property damage and/or product malfunction.
1. For safety reasons the LED light engine must not be operated if the housing is damaged.
2. The LED engine needs to be built into a luminaire.
3. Suitable only for operation with 120Vac input voltage.
4. Conducting paths on the circuit board must not be damaged or destroyed during installation.
5. The LED module itself and all its components may not be mechanically stressed.
6. It is highly recommended to use a thermal interface material (TIM). The TIM needs to enable adequate heat transfer, during installation it has to be taken
care not to create air inclusions between surfaces. For this purpose, it is recommended to use a heat sink with even and clean surfaces.
7. T he LED module should be mounted to a heat sink with M3 screws or suitable accessories. Maximum tightening torque for mounting screws need to be
observed as excessive force may damage the housing.
8. Protect against splashes!
9. D
amage by corrosion will not be honored as materials defect claim. PrevaLED Core is recommended for indoor use only (IP 20). It is the user's responsibility
to provide suitable protection against corrosive agents, such as moisture, condensation and other harmful elements.
10. T o avoid mechanical damage, the LED modules have to be attached securely to the intended mounting surface. It is recommended to avoid heavy vibration.
11. D
o not remove the cover or the safety glass from the LED module. Do not operate an LED module when the safety glass is broken, missing or cracked.
12. Installation of LED module needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to
perform installation.
13. Pay attention not to exceed the maximum operation temperature of 90°C at the Tc point when the modules are used in an enclosed environment.
14. The design of the housing/luminaire should be according to the IP standards applicable for the intended application.
15. For maximum safe operation per UL, refer to Conditions of Acceptability (CoA).
16. Maximum operating temperature for warranty coverage is 90°C.
Americas Headquarters
OSRAM SYLVANIA Inc.
100 Endicott Street
Danvers, MA 01923 USA
Phone 1-800-LIGHTBULB (1-800-544-4828)
www.osram-americas.com
OSRAM, PrevaLED, LED CREATING TOMORROW and OPTOTRONIC are registered trademarks of OSRAM GmbH.
Specifications subject to change without notice.
© 2015 OSRAM