Wireless Smart Metering LAN-WMBUS-M
Transcription
Wireless Smart Metering LAN-WMBUS-M
Wireless Smart Metering LAN-WMBUS-M Wireless MBUS, door and window sensor. With optional glass break accessory. The LAN-WMBUS-M (I/A) (G)/(E)- is a activity sensor for detecting for example openings/closing of windows, doors etc. It can also be used for counting the number of openings in a certain timeframe. The sensor can be ordered in different configurations see the product matrix for more details. The devices have the following features. Wireless MBUS EN13757- 3/4:2013 Standard. S, T and Cmode are supported. Superb antenna design and high output power for long range. Onboard Magnet sensor. Possibility to connect external wired magnet detector (E) Possibility to connect external wired glass break detector (G) Values can be send instantaneous (I) or accumulated (A). Sabotage detection if sensor is opened or removed from wall. AES 128 encryption. CBC Mode 5 OMS compliant. Very long battery lifetime, up to 14 years. Depending on how many openings, and MBUS-mode. Wide operating temperature range - 20 to +55 degree C. (other temperatures upon request) Plug & Play. Works right out the box, no complex installation needed. Low battery alarm. Available with optional high quality battery. Datasheet v1.1 Product description The device is made up of a sensor and a magnet. Whenever the magnet is removed or returned to the sensor a message is sent (I-variant). The number of passages can also be accumulated and the total number of passages is transmitted in even intervals (A- Accumulated). Is also possible to further enhance the device by connect an external magnet detector through cabling (E-variant) or connect it to Lansen Glass Break device (G). Product Matrix Article Number External External Inputs LAN-WMBUS-M - - LAN-WMBUS-ME Magnet 2 LAN-WMBUS-MG GlassBreak 1 interface Visiting address Mail adress Email Lansen Systems AB Lansen Systems AB [email protected] Science Park Box 186 Pilefeltsgatan 73 SE-301 05 Halmstad Halmstad Sweden www.lansen.se Datasheet v1.1 Radio characteristics Frequency S-Mode 868.3 MHz T-Mode 868.95 Mhz C-Mode 868.95 Mhz Chiprate S-Mode 32.378 kcps T-Mode 100 kcps C-Mode 100 kcps Datarate S-Mode Chiprate /2 T-Mode Chiprate x 2/3 C-Mode Chiprate RF output power 12dBm Antenna Integrated Transmission intervals accumulated values 15 minutes (other intervals are also available). 30 seconds during the first 4 minutes after powerup. Retransmission 3 times for alarm (sabotage, Alarm) 2 times for other messages. Power and battery Power consumption Max 40 mA, Battery type SAFT LS 14500 3.6 V - AA Primary Li-SOCL2 (recommended) Max operating voltage 3.6V Minimum operating voltage 2.8V Lifetime Typical more than 10 years. W-MBUS Info Header type EN13757-3 APPLAYER LONG TRANSPORT HEADER (0X72) Encryption AES 128 CBC (mode 5) Sensor type 0x1D Door and Window device. Low battery warning Yes Manufacture code LAS (standard, other code if requested) Visiting address Mail adress Email Lansen Systems AB Lansen Systems AB [email protected] Science Park Box 186 Pilefeltsgatan 73 SE-301 05 Halmstad Halmstad Sweden www.lansen.se Datasheet v1.1 -A and -I variant Accumulated value. 12 BCD digits, instantiations accumulated value from the power up of the device Example: 012345678912 Data is sent using H.C.A. That is unconverted data value. DATA_FIELD_BCD_12_DIGIT; 0x0E H.C.A 0x6E Number of openings detected 0x01,0x23,0x45,0x67,0x89,0x12 Sabotage Detected Message. X->don´t care that is not affected by the changed alarm The sabotage message is always sent in two ways: condition. Sabotage using Error Flag message. 0x02; (DIF field 2 byte integer) 0xFD; (VIF Extension table) The message is only sent when the status of sabotage is 0x17; (VIFE Error flags binary manufacture specific 16 bits) (2 changed. bytes) Sabotage detected ….XXXX1 (Bit 0) Sabotage restored ….XXXX1 (Bit 0) Sabotage using the manufacture specific status-byte in Sabotage detected EN13757-3 APPLAYER LONG TRANSPORT HEADER (0X72). 1 (Bit 5) The bit is set to 1 as long as sabotage is detected. 0 (Bit 5) Low battery EN 13757-3:2013 Table 7 Coding of the status field Low battery is sent using the power low bit in the status-byte Battery low 1 (Bit 2) Sabotage restored in EN13757-3 APPLAYER LONG TRANSPORT HEADER (0X72) Battery OK 0 (Bit 2) -I Only variant Alarm sent etc using the following encoding if any of the 3 alarm status have changed. The current status of the all 3 alarm ports are sent. X->don´t care, that is not affected by the changed alarm condition. Alarm message is sent using Error Flag 0x02; (DIF field 2 byte integer) changed. 0x97; message as soon as the alarm status is 0xFD; (VIF Extension table) Visiting address Mail adress Email Lansen Systems AB Lansen Systems AB [email protected] Science Park Box 186 Pilefeltsgatan 73 SE-301 05 Halmstad Halmstad Sweden www.lansen.se Datasheet v1.1 0x1D; (VIFE Error flags binary 16 bits) (2 bytes) . Alarm detected (door opened) …XXXXXX1XX (Bit2) -> Any Reed are IN alarm condition (any door open) … Alarm restored (door closed) …XXXXXX0XX (Bit2) -> Reeds are NOT in alarm condition (all doors closed) Examples: X is don’t care and is not affected by the change in alarm condition. . Operating conditions Storage temperature - 55 to + 85 gr C Operating temperature, -20 to + 55 gr C (other temperature upon request) Relative moisture Less than 95% non-condensing Casing Colour White Dimensions 25,5 x 105 x 22 mm Material ABS Conformity EMC EN 301489 Safety EN 60950 Radio EN 300 220 Visiting address Mail adress Email Lansen Systems AB Lansen Systems AB [email protected] Science Park Box 186 Pilefeltsgatan 73 SE-301 05 Halmstad Halmstad Sweden www.lansen.se Datasheet v1.1 Features for easier installation. Red LED indication when sabotage is detected When: When the device is opened or removed from the wall. (sabotage is detected) What: The LED flashes for 4 seconds at 4 Hz. Why: In order to verify that the sabotage detection is working. Red LED indication when When: When the device is closed or placed against the wall again(sabotage is restored) sabotage is restored What: The LED flashes for 2 seconds at 1 Hz. Why: In order to verify that the sabotage is restored and the device is closed and mounted correctly. Red LED indication of Alarm. When: When the magnet is removed from the device the red led is lit. This only apply to the first 4 minutes of operation (after battery is inserted) What: The LED is lit during alarm condition (door is opened) and turned off again after the magnet is placed nearby the device again ( door is closed) Why: In order to verify that the magnet and device is correctly mounted and is working as intended. Changelog Revision 1.1 Changed the packet type for sabotage and Alarm to better comply with the Alarm message in the MBUS standard. The Martin Hallberg new version is used in software version 2 of the LANWMBUS-M. Corrected the physical size of the device. Added information for the RED led during alarm condition. Changed device type from 0x1B to 0x1D Visiting address Mail adress Email Lansen Systems AB Lansen Systems AB [email protected] Science Park Box 186 Pilefeltsgatan 73 SE-301 05 Halmstad Halmstad Sweden www.lansen.se 2015-10-12