1 | Overview
2 | Installation notes
DS7428-CHI Bus Extender Module
can extend using the DS7400 Series
MUX Bus. It can accommodate long
distance applications of the MUX
Bus up to 5 km in a single loop. The
DS7428-CHI requires a 12 VDC to
the power supply. All MUX devices
(including DS7457i, DS7432, DS3MX,
and DS6MX) can connect directly to
the DS7428-CHI bus.
These installation instructions assume
the control panel is installed and in
proper working condition.
DS7428-CHI
1ST
2ND
5
1
12V GND
+ MUX -
12V GND
INPUT
2
+
Bus A
12V GND
+
Bus B
3
4
Figure 1.1: Module overview
Callout ― Description
1 ― External power source (12 VDC)
2 ― DS7430/DS7436 MUX Bus Driver
input
3 ― MUX Bus output A
4 ― MUX Bus output B
5 ― Jumpers
1.1 | Compatible modules
Supported MUX Bus Modules includes
DS7432, DS7457/DS7457i, DS7460/
DS7460i, DS7465/DS7465i,DS3MX/
DS3MX-CHI, DS6MX/DS6MX-CHI.
Refer to the DS7400Xi-CHI Installation
Instructions for additional wiring
information.
CAUTION!
Failure to follow the
installation instructions in this
manual might result in damage
to the control panel.
Disconnect the power to the DS7400
Series Control Panel before you run
wires to connect the DS7428-CHI.
Install the DS7428-CHI in an enclosure
and in dry conditions.
•
Use only non-shielded and nontwisted cable (1.0 mm2 or above) for
the wiring in the MUX Bus (including
the Extend Distance Bus).
•
Without the DS7428-CHI, the longest
distance of the MUX Bus is 1.5 km.
•
A single loop MUX Bus can reach 5
km after installed with DS7428-CHI.
•
The wiring distance between
the first-level DS7428-CHI and
the DS7400Xi-CHI Control Panel
should be less than 1 m. The firstlevel DS7428-CHI can support Bus
diastance for 3.5km.
•
When the second-level DS7428CHI is installed, it can extend an
additional 1.5 km. The total distance
can reach 5 km of two levels of
DS7428-CHI.
•
In each DS7400Xi system when using
a DS7430 MUX Bus Driver, you can
only install maximum three pieces
of DS7428-CHI. In addition, you
can install maximum six pieces of
DS7428-CHI when you use DS7436
MUX Bus Driver.
•
The first-level DS7428-CHI should be
installed as close as to the DS7430/
DS7436 module, and connect the
input power. Use an independent
power source to support the remote
second-level DS7428-CHI (refer to
Figure 3.1 and Figure 3.2).
4 | Wire jumper instructions
•
•
Try to avoid running wires dispersedly.
DS7428-CHI has an isolation feature.
When the DS7428-CHI detects the MUX
bus fault, it isolates the loop.
Avoid connecting DS7428-CHI in
parallel. Using one first-level DS7428CHI can improve the reliability of
system.
When using the DS7428-CHI in a first
level connection, place the single loop
bus jumper wire to the “1ST” position
at P2.
DS7428-CHI
1ST
2ND
3 | Wiring diagrams
DS7428-CHI
12V GND
+ MUX -
12V GND
INPUT
1
2
+
-
12V GND
Bus A
+
-
Bus B
3
Figure 4.1: First-level connection wiring
When using the DS7428-CHI in a second
level connection, place the single loop
bus jumper wire to “2ND” at P2.
4
DS7428-CHI
Figure 3.1: First-level connection wiring
1ST
Callout ― Description
2ND
1 ― DS7400Xi power supply input
2 ― Bus Driver Input for DS7430 or
DS7436 MUX Bus Driver
Figure 4.2: Second-level connection
wiring
3 ― MUX Bus output A
4 ― MUX Bus output B
DS7428-CHI
12V GND
+ MUX -
INPUT
12V GND
+
-
Bus A
12V GND
+
-
Bus B
+-
1
2
3
4
Figure 3.2: Second-level connection wiring
Callout ― Description
1 ― External power source
2 ― Bus Driver Input from first-level
DS7428-CHI MUX Bus output A or B
3 ― MUX Bus output A
4 ― MUX Bus output B
7 | Specifications
5 | System Overview with DS7430
Each loop Bus not more than 5 km *
MUX A
MUX A
DS7430
DS7428
MUX B
MUX Bus 3.5 km
MUX Bus 1.5 km
DS7428
MUX B
MUX Bus 3.5 km
DS7428
MUX Bus 1.5 km
MUX A
MUX B
DS7400Xi
Figure 5.1: System overview with DS7430
Dimensions
146 mm x 89 mm
Voltage
(operating)
12 VDC nominal
(10-13.2 VDC)
Current
(maximum)
120 mA
Operating
temperature
-40° C to +65° C
Relative
humidity
0% to 99%
MUX Bus
Connection
Request
1.0 mm2 above
MUX Bus
5 km (longest distance)
Compatibility
DS7400 Series Control
Panels
Bus Extender Module
DS7428-CHI
en Installation Guide
6 | Configuration with DS7436 MUX Bus Driver Module
Each loop Bus not more than 5 km *
MUX A
MUX A
DS7436
BUS A
DS7428
MUX B
MUX Bus 3.5 km
DS7428
MUX B
MUX Bus 3.5 km
BUS B
MUX Bus 1.5 km
DS7428
MUX A
MUX Bus 1.5 km
MUX B
MUX A
DS7400Xi
MUX A
DS7428
MUX B
MUX Bus 3.5 km
MUX Bus 1.5 km
DS7428
MUX B
MUX Bus 3.5 km
DS7428
MUX A
MUX B
MUX Bus 1.5 km
Copyright
This document is the intellectual property
of Bosch Security Systems, Inc. and is
protected by copyright. All rights reserved.
Trademarks
All hardware and software product
names used in this document are likely
to be registered trademarks and must be
treated accordingly.
Bosch Security Systems, Inc. product
manufacturing dates
Use the serial number located on the
product label and refer to the Bosch
Security Systems, Inc. website at
http://www.boschsecurity.com/datecodes/.
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.us
Figure 6.1: System overview with DS7436
CAUTION!
* Total wire length per loop should not exceed 5 km.