Integrated System Platform
Transcription
Integrated System Platform
™ Integrated System Platform DAB-801 Q-Sys™ Amplifier and I/O Frame Backup Accessory Features • One DAB-801 unit can provide N+1 instantaneous 2-channel switchover redundancy for up to 8 amplifier output channels • Two DAB-801 units can be cascaded to provide 2 or 4-channel switchover redundancy for up to 16 amplifier output channels • Automatic detection & switchover between inputs from Primary and Backup I/O Frames, in case of failure “upstream” • Fault tolerant control & monitoring of each DAB-801 is available using simultaneous GPIO terminals connected to both Primary and Backup I/O Frames • Two additional non-networked analog “high line” level inputs provide emergency evacuation signal which can override all other input signals • QSC Dataport Connectors and High Current Terminal Blocks for easy & reliable installation • Q-Sys technical support is available 24/7 - worldwide The purpose of the DataPort Amplifier Backup Panel is to provide redundancy, emergency paging, and other functionality required for many Life-Safety & Evacuation or mission-critical audio systems. monitored by Q-Sys along with the power-on status of the backup amplifier. Periodic full tests of the backup system can be programmed to ensure signal integrity and meet regulatory requirements. The DAB-801 extends the Q-Sys fault-tolerant backup capability to include any QSC DataPort power amplifier and I/O Frames populated with Q-Sys DataPort cards. The DAB-801 provides the ability to add true N+1 amplifier redundancy to any Q-Sys system, plus the ability to automatically switch amplifier input sources from a primary I/O Frame to a backup I/O Frame. Additionally two analog “high line” level inputs allow for direct connection of a carbon-type microphone, or a linelevel pre-recorded message for emergency evacuation paging which can then override all other input signals. A normal low impedance paging microphone may also be connected with the addition of an external microphone preamp. A single DAB-801 supports four 2-channel primary amplifiers with one 2-channel backup amplifier, or two 4-channel primary amplifiers with one 4-channel backup amplifier. Two DAB- 801s can be stacked to provide double the primary amplifier redundancy. Using these analog inputs, each DAB-801 has two priority modes, Alarm and Page. The Alarm input overrides all other signals, and is used for major emergencies. The Page input overrides all signals except the Alarm input, and can be used for other announcements. These inputs can be assigned to any combination of amplifier channels, and can be activated with either a standard contact closure or +12VDC trigger voltage from the fire alarm panel. Two D-Sub 15 pin connections allow direct connection to a pair of Q-Sys I/O Frames for full control and monitoring of the DAB-801 through the Q-Sys Designer software. All primary amplifiers are continuously The DAB-801 is easily integrated into a Q-Sys based audio system. Mounted onto the rear of a rack, the DAB-801 minimizes rack space consumption. AC line connection is fast and easy with an IEC style quick-disconnect and locking bracket to ensure reliable AC mains connection. A one world power supply operates on 100-240VAC, 50/60Hz. By using QSC standard HD-15 DataPort connectors and high current detachable terminal blocks, the DAB-801 provides an easy to install connector set. Various LED indicators alert the user to current panel status. The LEDs include an AC power indicator, I/O Frame power status indicators, amplifier power status indicators, I/O Frame failure indicators, and amplifier failure indicators. Each DAB-801 connects up to eight loudspeaker circuits, which may also be 100V transformer isolated. ™ Legend: Single I/O Frame (pictured here with 2-Channel amplifiers) 2-CH DataPort cable / bi-directional Audio Cable Q-Lan Network Speaker Lines / Hi-Z or Low-Z GPI/O Cable Q-Sys LAN PRIMARY Q-Sys I/O Frame 2-CH DataPorts GPIO Loudspeaker circuits Mic Pre Emergency Page Mic DAB 801 Pre-recorded Emergency Message PRIMARY Dataport 2-CH Amplifiers CH1 ON 10 12 70V CH2 CLIP -10dB 8 6 14 4 CH1 ON 10 12 6 CH1 ON 10 12 70V 6 CH1 10 12 70V CH2 CLIP -10dB 8 6 14 18 CX3 0 2 V DIRECT (35dB) CH1 8 (35dB) 6 DIRECT 70V 4 2 4 4 2 (35dB) 0 ATTEN 10 12 PARALLEL 8 6 14 4 2 24 POWER 0 (35dB) 8 6 24 18 SIGNAL 2 24 AMPLIFIER 0 CH2 -20dB 18 CX3 0 2 V 0 ATTEN CLIP -10dB 8 14 4 2 24 BRIDGE 10 12 6 18 SIGNAL POWER 0 ATTEN 10 18 SIGNAL POWER 0 (35dB) ATTEN ON 10 12 14 -20dB 4 2 24 AMPLIFIER 12 14 -20dB 4 2 24 AMPLIFIER BRIDGE ON 6 (35dB) ATTEN PARALLEL CH2 CLIP -10dB 8 14 18 CX3 0 2 V DIRECT 8 24 ATTEN BRIDGE BACKUP Dataport 2-CH Amplifier 10 12 14 18 SIGNAL POWER 0 (35dB) 0 ATTEN PARALLEL CH2 -20dB 4 2 24 AMPLIFIER CLIP -10dB 8 14 18 CX3 0 2 V 70V 4 2 (35dB) ATTEN BRIDGE DIRECT 6 24 POWER 0 (35dB) 8 18 SIGNAL 2 24 AMPLIFIER 10 12 14 -20dB 18 CX3 0 2 V DIRECT 0 (35dB) ATTEN ATTEN PARALLEL BRIDGE PARALLEL Backup I/O Frame (pictured here with 4-Channel amplifiers) Q-Lan Network BACKUP Q-Sys I/O Frame 2-CH DataPorts PRIMARY Q-Sys I/O Frame 2-CH DataPorts GPIO Loudspeaker circuits Mic Pre Emergency Page Mic DAB 801 Pre-recorded Emergency Message PRIMARY Dataport 4-CH Amplifiers CH1 2 CLIP (31dB) ATTEN BACKUP Dataport 4-CH Amplifier CH1 CH1 ON 12 10 70V AMPLIFIER (35dB) 10 ON 0 10 12 CX404 PROFESSIONAL AMPLIFIER 14 6 2 O0 (31dB) ATTEN 0 SIG 10 12 8 6 14 2 O0 (31dB) ATTEN 0 10 12 8 6 18 24 CH4 -10dB -20dB PAR 14 18 24 CLIP 3&4 BRDG 10 12 8 18 3 POWER 1&2 SIG 4 2 (35dB) ATTEN PARALLEL -20dB 6 24 BRIDGE 8 18 SIGNAL POWER 0 ATTEN 2 -10dB 12 14 -20dB 4 2 24 CLIP CH2 CLIP -10dB 8 6 14 18 CX3 0 2 V DIRECT 14 8 6 4 18 24 2 O0 (31dB) ATTEN 0 24 2 O0 (31dB) ATTEN 0 14 0 6 14 2 O0 (31dB) ATTEN 0 10 12 8 6 18 24 CH4 SIG 10 12 8 18 2 O0 -20dB PAR 10 12 8 6 24 -10dB BRDG SIG 14 18 CLIP 3&4 -20dB 10 12 CX404 PROFESSIONAL AMPLIFIER 3 POWER 1&2 -10dB ON 14 8 6 4 18 24 2 O0 (31dB) ATTEN 0 24 2 O0 (31dB) ATTEN 0 Common DAB-801 Configurations Two linked DAB-801’s using Extension Bus (pictured here with 2-Channel amplifiers) Legend: 2-CH DataPort cable / bi-directional Audio Cable Speaker Lines / Hi-Z or Low-Z CH1 ON 12 10 70V CH2 CLIP -10dB 8 6 14 6 4 2 24 POWER 0 (35dB) 8 18 SIGNAL 2 24 AMPLIFIER 10 12 14 -20dB 4 18 CX3 0 2 V DIRECT 0 (35dB) ATTEN ATTEN BRIDGE PARALLEL GPI/O Cable CH1 ON 10 12 Q-Sys LAN 70V CH2 CLIP -10dB 8 6 14 6 4 2 24 POWER 0 (35dB) 8 18 SIGNAL 2 24 AMPLIFIER 10 12 14 -20dB 4 18 CX3 0 2 V DIRECT 0 (35dB) ATTEN ATTEN BRIDGE PARALLEL CH1 ON 10 12 70V CH2 CLIP -10dB 8 6 14 18 CX3 0 2 V DIRECT 8 6 18 SIGNAL 4 2 24 POWER 0 (35dB) 10 12 14 -20dB 4 2 24 AMPLIFIER 0 (35dB) ATTEN ATTEN BRIDGE PARALLEL CH1 ON 10 12 70V CH2 CLIP -10dB 8 6 14 12 4 6 4 2 24 POWER 0 (35dB) 8 18 SIGNAL 2 24 AMPLIFIER 10 14 -20dB 18 CX3 0 2 V DIRECT 0 (35dB) ATTEN ATTEN BRIDGE PARALLEL PRIMARY Dataport 2-CH Amplifiers Loudspeaker circuits DAB 801 GPIO Speaker Extension Bus 2-CH DataPorts BACKUP Q-Sys I/O Frame Control Extension Bus Q-Lan Network PRIMARY Q-Sys I/O Frame GPIO 2-CH DataPorts Loudspeaker circuits DAB 801 PRIMARY Dataport 2-CH Amplifiers CH1 ON 10 12 70V 6 CH1 ON 10 12 6 BACKUP Dataport 2-CH Amplifier CH1 ON 10 12 70V 6 CH1 12 10 70V AMPLIFIER CH2 CLIP -10dB 8 6 14 18 CX3 0 2 V DIRECT (35dB) 10 12 6 (35dB) ATTEN PARALLEL 10 18 CX3 0 2 V 0 DIRECT 70V AMPLIFIER 12 (35dB) 10 18 SIGNAL 4 2 24 POWER 0 (35dB) ATTEN ATTEN BRIDGE 8 6 14 -20dB 4 2 24 PARALLEL 0 8 6 4 2 (35dB) ATTEN CH2 CLIP -10dB 8 6 14 4 2 24 BRIDGE 8 18 SIGNAL POWER 0 ATTEN CH1 ON 12 14 -20dB 4 2 24 10 24 BRIDGE ON 12 14 18 SIGNAL POWER 0 (35dB) ATTEN PARALLEL 10 0 8 6 4 2 (35dB) ATTEN CH2 -20dB 4 2 24 AMPLIFIER CLIP -10dB 8 14 18 CX3 0 2 V DIRECT 12 14 24 BRIDGE PARALLEL 0 8 6 4 2 (35dB) ATTEN 18 SIGNAL POWER 0 (35dB) ATTEN 10 24 CH2 -20dB 4 2 24 AMPLIFIER CLIP -10dB 8 14 18 CX3 0 2 V 70V 12 14 18 SIGNAL POWER 0 (35dB) ATTEN BRIDGE DIRECT CH2 -20dB 4 2 24 AMPLIFIER CLIP -10dB 8 14 18 CX3 0 2 V DIRECT PARALLEL 0 ™ Specifications DAB-801 Connectors Input Output Other 6 Position “Euro” or “Phoenix” type, QSC DataPort (HD-15), QSC GPIO (DB-15). QSC DataPort (HD-15), 8 position high current “Euro” or “Phoenix” type. Control Extension Bus (DB-37), IEC type AC Inlet. Controls Page Assignment: 8 position “dip” type toggle switch Page/Alarm Inputs Balanced 5k ohm, 3 Vrms. LED Indicators Power (blue, 1 each). NORMAL (green, 8 each, 1 per primary DP). FAULT (red, 8 each, 1 per primary DP). BACKUP ACTIVE (yellow, 6 each, 1 per backup DP) Maximum Amplifier Ratings 1200 W per channel Power Requirements 100 – 240 VAC, 50 – 60 Hz, 12 W max. Operating Temperature (Tma) 0˚C – 40˚C non condensing Dimensions (HWD) 7" (17.8 cm) 4 RU x 19" (48.3 cm) rack mounting x 2" (5.1 cm) Weight (net/shipping) 7.8 lb (3.5 kg) / 10.8 lb (5kg) 17.14±0.0 [435.3±0.3] 6.96±0.0 [176.8±0.3] FRONT VIEW REAR VIEW SCALE: 1:1 please recycle ©2011 QSC Audio Products, LLC. All rights reserved. QSC and the QSC logo are registered trademarks of QSC Audio Products, LLC in the U.S. Patent and Trademark office and other countries. Q-Sys is a trademark of QSC Audio Products, LLC. 1675 MacArthur Boulevard • Costa Mesa, CA 92626 • Ph: 800/854-4079 or 714/957-7100 • Fax: 714/754-6174 Q-Sys DAB-801 Spec Sheet - 05/09/11 qscaudio.com