Generating a Bill of Materials

Comments

Transcription

Generating a Bill of Materials
Generating a Bill of Materials
For Tech Lighting Systems
Encompass Lighting Group
7400 Linder Ave.
Skokie, IL 60077
CUSTOMER SUPPORT
AND QUOTATIONS:
800.522.5315
FAX:
847.410.4500
WEBSITE:
www.encompasslighting.com
921TLBOM09
W H AT I S A B I L L O F M AT E R I A L S ?
A bill of materials is the list of product item numbers that are required to accurately
price and supply a lighting system.
Before you begin, you will need a rough plan of the lighting required for your project
or a list of the pieces your client has requested.
Process overview
1. Use the catalog to help you select the appropriate system, elements, and options
for your design.
2. Use the layout worksheet to gather information.
3. Use the detailed steps in this booklet to determine the exact item numbers of the
products required for the project.
Tools
L AY O U T W O R K S H E E T
847.410.4400
Quotes Dept. Fax:
847.410.4720
www.techlighting.com
Date ____________________ Rep _______________________________________________
Job name/location _____________________________________________________________
Submitter’s name ______________________________________________________________
Company ____________________________________________________________________
Phone _________________________________ Fax _________________________________
SYSTEM
K Tech Lighting MonoRail (p. 6)
K Tech Lighting Wall MonoRail (p. 48)
K Wilmette MonoRail (p. 4)
K StraightLine (p. 26)
ELEMENTS
Elements to be used (specify):
Name/Length
K Tech Lighting Two-Circuit MonoRail (p. 30)
K Tech Lighting Kable Lite MonoRail (p. 60)
K T~trak (p. 6)
Note: pages numbers refer to
their respective catalogs
K Element
™
Quantity
Color/Finish
Accessory/Finish/Color
Lamp/Watts
1st Type
2nd Type
3rd Type
4th Type
Total No. of Elements:
FINISH
DRAWING
Total Wattage:
K Antique Bronze
K Chrome
K Satin Nickel
K White
K Custom finish or colored insulator (specify) ________________________________________________
Attach scaled drawing or provide on reverse side.
K Plan view
K Elevation
LENGTH
Length of run:
TRANSFORMER
K Remote:
K 1/8” = 1’
K 1/2” = 1’
Scale:
K 1/4” = 1’
K Not to scale
If custom curve, supply degree and radius:
(low-voltage systems only)
(p. 270)
K Magnetic OR
K Electronic
K 12V
K 4” Round
K Direct End
K 2” Square
K Other___________
K Rectangular
K Surface:
K Magnetic OR
K Electronic
K 12V
K 24V
Output Wattage:
Canopy/Power Feed type:
K 24V
Output Wattage:
If using existing junction boxes, show location on drawing.
MOUNTING
If ceiling mounted, how far below the ceiling will the system be dropped? (circle)
3”
4”
5”
6”
2”
6”
12”
24”
36”
Tech Kable Lite:
1”
2.5”
5”
12”
18”
24”
Wilmette MonoRail:
Tech MonoRail:
2”
3”
4”
5”
6”
12”
24”
T~trak:
2”
6”
12”
24”
36”
48”
96”
Tech Two-Circuit MonoRail:
SPECIAL
Tech Lighting
Full Line Catalog
Wilmette
Full Line Catalog
T~trak
Full Line Catalog
This Booklet
2”
12”
48”
24”
36”
48”
96”
36”
48”
96”
96”
Is the ceiling vaulted?
K Yes
K Cantilever
K Other (specify) _________________________________________
K No
Layout Worksheet
Additional resources
Your local Encompass Lighting sales representative can provide you with product
information and pricing. For the name and phone number of your local rep, visit our
website: www.encompasslighting.com.
Also visit our website for technical and product information, including spec sheets and
installation instructions.
Our toll-free Quotation and Customer Support Hotline, 800.522.5315 is available
Monday-Friday, 8:30 a.m.-5:00 p.m. Central Standard Time.
www.encompasslighting.com
2
TA B L E O F C O N T E N T S
Tech Lighting Systems
MonoRail
pp. 4-7
Two-Circuit MonoRail
pp. 8-11
Wall MonoRail
pp. 12-15
Kable Lite
pp. 16-19
Wilmette Systems
MonoRail
pp. 20-23
T~trak Systems
T~trak
pp. 24-27
www.techlighting.com
3
MONORAIL SYSTEM
www.techlighting.com
4
MONORAIL SYSTEM
Step One: Design Your Tech Lighting MonoRail System
Page numbers below reference the Tech Lighting Full-Line
Catalog (921TLFLCAT09), unless indicated otherwise.
QTY.
E L E M E N T S (Pendants, Heads, and Functional Art):
Choose elements from product overview (pp. 14-17).
Determine item number(s) (pp. 28-129).
ITEM NUMBER
700MO ___________________
700MO ________________
700MO ___________________
700MO ___________________
Choose Accessories and Optical Controls,
if required or desired (pp. 28-129).
Determine item number(s) (pp. 326-339).
700 ______________________
Choose lamps, 12 or 24 volt, that do not exceed
maximum wattage of element or accessory
(may be included; pp. 28-129).
Determine item number(s) (pp. 340-341).
300BLV ________________
300BLV ___________________
Add up total lamp wattage on system.
_____________
________ watts watts
700 ______________________
___________________
________________
300BLV ___________________
FINISH:
Choose finish of system and make sure all components
are specified as such.
( ZC ) ACNHTRI O
QM
U EE B R O N Z E
(C
G)) CGHORLODM E
(LS ) S AT I N N I C K E L
DRAWING:
Use scaled drawing as a reference.
LENGTH:
Measure length of MonoRail run; determine quantity
and length of MonoRail pieces required (p. 240).
700MOA __________________
______________
700MOA
700MOA __________________
Specify one pair of End Caps for each open end of run (p. 241).
700MOA ______________
700MOCCAP
700MOCCAP _______________
_________
Determine number of Standoffs, one for every three feet of run.
## of
of standoffs
standoffs ______________
___________
Does the run include a sharp angle or turn?
If so, specify a Flexible Connector to make the turn (p. 241).
700MOCFXH
700MOCFXH _______________
__________
Would you like the Rail to be custom bent at the factory? If so, please
provide the degree and radius of each curve by fax to the quotes
department, 847.410.4720, for a quotation.
www.techlighting.com
5
MONORAIL SYSTEM
Step Two: Add Power and Hardware to Complete the System
QTY.
ITEM NUMBER
T R A N S F O R M E R **:
Remote Transformer (p. 244)
Choose:
Magnetic or electronic
12 volt or 24 volt
*Output wattage _________
Single or dual-feed
700AT ________________
AND
AND
Specify a Power Feed Canopy, single or dual-feed (p. 245).
700MOP ______________
OR
OR
Surface Transformer (p. 246)
Choose:
Magnetic or electronic
12 volt or 24 volt
*Output wattage _________
Single or dual-feed
700MO _______________
*Wattage of the transformer must meet or exceed wattage of lamps calculated on previous page.
**If you are using LED heads or pendants, be sure to choose a transformer that is compatible with LED fixtures.
If powering system with more than one Transformer, add
Isolating Connectors (p. 241) to isolate the feeds from each other.
700MOCINC
If dropping system a distance below ceiling, add one
Power Extender (p. 245) to each Power Feed
(add two when using dual-feed).
700MOP ______________
MOUNTING:
Select Standoffs (p. 242) that match or exceed drop of the
Surface Transformer or Power Feed. Refer to Length section
on previous page for quantity.
Is the ceiling vaulted? If so, specify one Power Vault Adapter (p. 250)
for each power feed (add two when using dual-feed).
Then specify one Standoff Vault Adapter for each Standoff (p. 250).
700MOS ______________
700MOPVLT ___________
700MOCVLT ___________
SPECIAL:
This outline covers only the most common MonoRail applications, but
MonoRail can do almost anything. For other MonoRail system options,
see Special Installations on (pp. 248-251) of the catalog, or call your local
representative or Tech Lighting quotes department (800.522.5315).
www.techlighting.com
6
MONORAIL SYSTEM
Sample Bill of Materials - As seen on p. 93 of the Tech Lighting Full Line Catalog
J
J
G
J
F
E
H
J
A
F
I
J
J
J
A
J
A
C
C
D
D
C
D
B
B
Item
Quantity
Item Number
Description
A
B
C
D
E
F
G
H
I
J
3
2
3
3
3
2
1
1
1
8
700MOAE3S
700MOCMLIFS
700MR16GF
300BLV136
700MOA96S
700MOCCAPS
700AT300T
700MOP4C02S
700MOP06S
700MOS04S
MO-Aero 3", Satin Nickel
MO-Camille, Inner Frost, Satin Nickel
Round Glass Shield Accessory, Frost, Aluminum
12v GE CC, Hal MR16, GU5.3 55˚ 50w
Clear MonoRail 96", Satin Nickel
MO End Caps, pair, Satin Nickel
Remote Magnetic Transformer, 12v 300w
MO Single Feed Canopy, 4" Round, Satin Nickel
MO Power Extender, 6", Satin Nickel
MO Rigid Standoff, 4", Satin Nickel
CHECKLIST
Make sure your Bill of Materials Includes:
Elements (pp. 28-129)
Accessories and Optical Controls (pp. 326-339)
Lamps—if not included with elements; (pp. 340-341, lamps must not exceed maximum wattage
of element or accessory)
MonoRail (p. 240)
End Caps (one pair for each open end; p. 241)
Transformer (pp. 244, 246)
Power Feed Canopy (for remote transformer; p. 245)
Power Extender (if necessary; p. 245)
Isolating Connectors (if necessary; p. 241)
Standoffs—one for every three feet of run (p. 242, standoff lengths must match power feed length)
Make sure all finishes match and item numbers end with Z (Antique Bronze), C (Chrome),
or S (Satin Nickel)
www.techlighting.com
7
TWO-CIRCUIT MONORAIL SYSTEM
www.techlighting.com
8
TWO-CIRCUIT MONORAIL SYSTEM
Step One: Design Your Tech Lighting Two-Circuit MonoRail System
Page numbers below reference the Tech Lighting Full-Line
Catalog (921TLFLCAT09), unless indicated otherwise.
QTY.
E L E M E N T S (Pendants, Heads, and Functional Art):
ITEM NUMBER
Choose elements from product overview (pp. 14-17).
Determine item number(s) (pp. 28-129).
700MO2 __________________
700MO2 ________________
700MO2 __________________
700MO2 ________________
700MO2 __________________
700MO2 ________________
Choose Accessories and Optical Controls,
if required or desired (pp. 28-129).
Determine item number(s) (pp. 326-339).
700
700 ______________________
___________________
700
700 ______________________
___________________
Choose 12 volt lamps that do not exceed
maximum wattage of element or accessory
(may be included; pp. 28-129).
Determine item number(s) (pp. 340-341).
300BLV ________________
300BLV ___________________
Add up total lamp wattage on system.
______________
__________ wattswatts
300BLV
300BLV ___________________
________________
FINISH:
Choose finish of system and make sure all components
are specified as such.
OU
MEE B R O N Z E
((ZC)) ACNHTRI Q
(( CG)) CGHORLODM E
(NS )NSI C
ATK IENL N I C K E L
DRAWING:
Use scaled drawing as a reference.
LENGTH:
Measure length of Two-Circuit MonoRail run; determine quantity
and length of Two-Circuit MonoRail pieces required (p. 260).
700MO2A ______________
700MO2A _________________
Specify one pair of End Caps for each open end of run (p. 261).
700MO2A _________________
700MO2A ______________
700MO2CCAP ______________
_________
700MO2CCAP
Determine number of Standoffs, one for every three feet of run.
of standoffs
standoffs ______________
___________
## of
Does the run include a sharp angle or turn?
If so, specify a Flexible Connector to make the turn (p. 261).
700MO2CFXH
700MO2CFXH ______________
__________
Would you like the Rail to be custom bent at the factory? If so, please provide
the degree and radius of each curve by fax to the quotes department,
847.410.4720, for a quotation.
www.techlighting.com
9
TWO-CIRCUIT MONORAIL SYSTEM
Step Two: Add Power and Hardware to Complete the System
QTY.
ITEM NUMBER
TRANSFORMER:
Remote Transformer (p. 264)
Choose:
Magnetic or electronic
12 volt
*Output wattage _________
Single or dual-feed
700AT ________________
AND
AND
Specify a Power Feed Canopy, single or dual-feed (p. 265).
700MO2P _____________
OR
OR
Surface Transformer (p. 265)
Choose:
Magnetic or electronic
12 volt
*Output wattage _________
Single or dual-feed
700MO2SRT ___________
*Wattage of the transformer must meet or exceed wattage of lamps calculated on previous page.
If powering system with more than one transformer, add
Isolating Connectors (p. 261) to isolate the feeds from each other.
700MO2CINC
If dropping system a distance below ceiling, add one
Power Extender (p. 265) to each Power Feed
(add two when using dual-feed).
700MO2P _____________
MOUNTING:
Select Standoffs (p. 262) that match or exceed drop of the
Surface Transformer or Power Feed. Refer to Length section on
previous page for quantity.
700MO2S _____________
Is the ceiling vaulted? If so, specify one Power Vault Adapter (p. 268)
for each power feed (add two when using dual-feed).
Then specify one Standoff Vault Adapter for each Standoff (p. 268).
700MO2PVLT __________
700MO2CVLT __________
SPECIAL:
This outline covers only the most common Two-Circuit MonoRail applications,
but Two-Circuit MonoRail can do almost anything. For other Two-Circuit
MonoRail system options, see Special Installations on (pp. 266-268) of the catalog,
or call your local representative or Tech Lighting quotes department (800.522.5315).
www.techlighting.com
10
TWO-CIRCUIT MONORAIL SYSTEM
SAMPLE BILL OF MATERIALS - As seen on p. 257 of the Tech Lighting Full Line Catalog
H
G
I
J
E
J
A
C
D
B
A
J
C
D
A
C
G
F
D
B
Item
A
B
C
D
E
F
G
H
I
J
Quantity
3
2
3
3
1
1
2
1
1
3
Item Number
700MO2AE6S
700MO2SAVWS
700MR16GF
300BLV138
700MO2A96S
700MO2A48S
700MO2CCAPS
700AT2X300T
700MO2P4C02S
700MO2S06S
Description
MO2-Aero 6", Satin Nickel
MO2-Savoy White, Satin Nickel
Round Glass Accessory, Frost
12v GE CC. Hal MR16 GU5.3 25˚ 50w
Clear Mono2Rail 96", Satin Nickel
Clear Mono2Rail 48", Satin Nickel
MO2 End Caps, Satin Nickel
2x300T Remote Magnetic Transformer, Single Feed
MO2 Single Feed Canopy, 4" Round, Satin Nickel
MO2 Rigid Standoff 2", Satin Nickel
CHECKLIST
Make sure your Bill of Materials Includes:
Elements (pp. 28-129)
Accessories and Optical Controls (pp. 336-339)
Lamps—if not included with elements; (pp. 340-341 lamps must not exceed maximum wattage
of element or accessory)
Two-Circuit MonoRail (p. 260)
End caps (one pair for each open end; p. 261)
Transformer (p. 264-265)
Power feed canopy (for remote transformer; p. 265)
Power extender (if necessary; p. 265)
Isolating connectors (if necessary; p. 261)
Standoffs—one for every three feet of run (p. 262, standoff length must match power feed length)
Make sure all finishes match and item numbers end with Z (Antique Bronze), C (Chrome)
or S (Satin Nickel)
www.techlighting.com
11
WALL MONORAIL SYSTEM
WALL MOUNTED
CEILING MOUNTED
www.techlighting.com
12
WALL MONORAIL SYSTEM
Step One: Design Your Tech Lighting Wall MonoRail System
Page numbers below reference the Tech Lighting Full-Line
Catalog (921TLFLCAT09), unless indicated otherwise.
QTY.
ITEM NUMBER
ELEMENTS:
WALL MOUNTED
Choose Wall MonoRail heads (p. 16).
Determine item number(s) (pp. 101-129).
CEILING MOUNTED
Choose elements from product overview (pp. 14-17).
Determine item number(s) (pp. 28-129).
Order one Wall MonoRail FreeJack Connector for each element (p. 315).
Choose Accessories and Optical Controls,
if required or desired (pp. 28-129).
Determine item number(s) (pp. 326-339).
Choose lamps, 12 or 24 volt, that do not exceed
maximum wattage of element or accessory (pp. 28-129).
Determine item number(s) (pp. 340-341).
Add up total lamp wattage on system.
700WM __________________
700WM __________________
700WM __________________
700FJ ____________________
700WMOCHED_____________
700WM _______________
700 _____________________
700 _____________________
700 __________________
300BLV __________________
_______________
300BLV
300BLV
__________________
LV _______________
______________
_________ watts watts
FINISH:
Choose finish of system and make sure all components
are specified as such.
(( ZC)) ACNHTRI Q
OU
MEE B R O N Z E
(( CG)) CGHORLODM E
(( SS )) SSAT
ATI INN NNI ICCKKEELL
DRAWING:
Use scaled drawing as a reference.
LENGTH:
Measure length of Wall MonoRail run; determine quantity
and length of MonoRail pieces required (p. 276).
700MOA _________________
700MOA _________________
Specify one pair of End Caps for each open end of run (p. 277).
Determine number of Standoffs needed, one for every
three feet of run.
www.techlighting.com
__________
700MOCCAP ______________
# of standoffs ________
# of standoffs _____________
13
WALL MONORAIL SYSTEM
Step Two: Add Power and Hardware to Complete the System
QTY.
ITEM NUMBER
T R A N S F O R M E R **:
Remote Transformer (p. 278)
Choose:
Magnetic or electronic
12 volt or 24 volt
*Output wattage _________
Single or dual-feed
700AT _________________
AND
AND
Specify a Power Feed Canopy (p. 279).
(if using a dual feed transformer be sure to order two canopies
and one isolating connector)
700WMOP ______________
OR
OR
Surface Transformer (p. 280)
Note: if using a Kable Lite Surface Transformer the transformer
must be mounted adjacent to run.
Choose:
Magnetic or electronic
12 volt or 24 volt
*Output wattage _________
Single
700SRT ________________
AND
AND
Specify a Center Power Feed or End Power Feed Connector
and determine item number (p. 279).
700MOP _______________
*Wattage of the transformer must meet or exceed wattage of lamps calculated on previous page.
**If you are using LED heads or pendants, be sure to choose a transformer that is compatible with LED fixtures.
If powering system with more than one transformer, add Isolating
Connectors (p. 277) to isolate the feeds from each other.
700MOCINC
MOUNTING:
Order Wall MonoRail Standoffs (p. 276).
Refer to Length section on previous page for quantity.
700WMOS01 ____________
SPECIAL:
This outline covers only the most common Wall MonoRail applications.
For other Wall MonoRail system options call your local representative
or Tech Lighting quotes department (800.522.5315).
www.techlighting.com
14
WALL MONORAIL SYSTEM
SAMPLE BILL OF MATERIALS - As seen on pp. 270-271 of the Tech Lighting Full Line Catalog
A
C
A
A
D
G
B
B
F
B
E
D
G
Item
A
B
C
D
E
F
G
Quantity
3
3
1
2
1
1
2
Item Number
700WMWAL12Z
300BLV138
700MOA96BRZ
700MOCCAPZ
700AT150T
700WMOP2SQZ
700WMOS01Z
Description
WMO-Wally Lite 12", Antique Bronze
12v GE CC. Hal MR16 Lamp, GU5.3 25˚ 50w
Brown MonoRail 96", Antique Bronze
End Caps, pair, Antique Bronze
Remote Magnetic Transformer, 12v 150w
WMO Power Feed Canopy, 2" Square, Antique Bronze
WMO Standoff, Antique Bronze
CHECKLIST
Make sure your Bill of Materials Includes:
Elements (pp. 28-129)
Lamps (pp. 340-341)
Accessories and Optical Controls (pp. 326-339)
Wall MonoRail (p. 276)
End Caps (one pair for each open end; p. 277)
Transformer (pp. 278, 280)
Power Feed Canopy (for Remote Transformer p. 279)
End or Center Power Feed (for Surface Transformer; p. 279)
Isolating Connectors (if necessary; p. 277)
Standoffs (one for every three feet of run; p. 276)
Make sure all finishes match and item numbers end with Z (Antique Bronze), C (Chrome),
or S (Satin Nickel)
www.techlighting.com
15
KABLE LITE SYSTEM
www.techlighting.com
16
KABLE LITE SYSTEM
Step One: Design Your Tech Lighting Kable Lite System
Page numbers below reference the Tech Lighting Full-Line
Catalog (921TLFLCAT09), unless indicated otherwise.
QTY.
ITEM NUMBER
E L E M E N T S (Pendants, Heads, and Functional Art):
Choose elements from product overview (pp. 14-17).
Check cable separation requirements. Cable separation
is usually 1", 2", 3.5", 5.5", or 8". 5.5" separation has most
element options. Determine item number(s) (pp. 28-129).
700K _____________________
Choose Accessories and Optical Controls,
if required or desired (pp. 28-129).
Determine item number(s) (pp. 326-339).
700 ____________________
700 ______________________
Choose lamps, 12 or 24 volt, that do not exceed maximum
wattage of element or accessory (may be included; pp. 28-129).
Determine item number(s) (pp. 340-341).
300BLV ___________________
Add up total lamp wattage on system
______________
______________ watts
watts
700K _____________________
700K _____________________
700
700 ______________________
____________________
300BLV
___________________
00BLV _________________
300BLV _________________
FINISH:
Choose finish of system and make sure all components
are specified as such.
((CC)) CCHHRROOMMEE
((SG) ) SG
AT
OILND N I C K E L
( S ) S AT I N N I C K E L
DRAWING:
Use scaled drawing as a reference.
Identify mounting locations for turnbuckles and any turns in the run.
LENGTH:
Measure length of Kable Lite run; determine distance in feet.
Order two times the length of run plus 10 percent (p. 290).
700KLA
_______
700KLA ____________
_________________
Choose turnbuckles to tighten cable (p. 291).
700
700 ______________________
____________________
700 ______________________
www.techlighting.com
17
KABLE LITE SYSTEM
Step Two: Add Power and Hardware to Complete the System
QTY.
ITEM NUMBER
T R A N S F O R M E R **:
Remote Transformer (p. 294)
Choose:
Magnetic or electronic
12 volt or 24 volt
*Output wattage _________
Single or dual-feed
700AT ___________________
AND
AND
Specify a Power Feed Canopy, single or dual-feed (p. 295).
700KP __________________
OR
OR
Surface Transformer (p. 296)
Choose:
Magnetic or electronic
12 volt or 24 volt
*Output wattage _________
Single or dual-feed
700 ____________________
*Wattage of the transformer must meet or exceed wattage of lamps calculated on previous page.
**If you are using LED heads or pendants, be sure to choose a transformer that is compatible with LED fixtures.
If powering system with more than one transformer, add Isolating
Connectors (p. 293) to isolate the feeds from each other.
700P ___________________
MOUNTING:
Determine how far below ceiling the system will drop. If using a
Surface Transformer drop must exceed height of Transformer (p. 296).
If mounting turnbuckles to ceiling and dropping the system a greater
distance below ceiling choose either Rigid T Standoff or Rigid Post
Standoff to mount before turnbuckles. Determine item number (p. 292).
700K ___________________
If cables will be making a turn off the wall specify either
Horizontal Turn or Wall Turn and determine item number (p. 293).
700 ____________________
If cables will be making a turn off the ceiling specify
Rigid Post Standoff Turn. Determine item number (p. 292).
700KSOT ________________
If using heavier elements, such as glass pendants, or if a span
of cable exceeds 20' without support, specify Adjustable Standoffs.
Determine item number (p. 293).
700PRTD3 _______________
SPECIAL:
This outline covers only the most common Kable Lite applications, but Kable Lite is very versatile.
For other Kable Lite system options, see Special Installations on (pp. 298-300) of the catalog,
or call your local representative or Tech Lighting quotes department (800.522.5315).
www.techlighting.com
18
KABLE LITE SYSTEM
SAMPLE BILL OF MATERIALS - As seen on p. 301 of the Tech Lighting Full Line Catalog
D
A
B
A
C
A
B
A
B
A
E
B
D
B
F
Item
A
B
C
D
E
F
Quantity
5
5
25 ft.
2
1
1
Item Number
700KBYENC
700BLV136
700KLABAREC
700KPARTTS
700AT300T
700KP4C24S
Description
K-Bye-Bye, Aluminum
12v GE CC. Hal MR16 Lamp, GU5.3 55˚ 50w
Bare Cable, Tin Plate, per ft.
Universal Turnbuckles, Satin Nickel
Remote Magnetic Transformer 12v 300w
KL Single Feed Canopy, 4" Round, Satin Nickel
CHECKLIST
Make sure your Bill of Materials Includes:
Elements (pp. 28-129), make sure selected cable separation works with elements)
Lamps—if not included with elements; (pp. 240-241, lamps must not exceed maximum wattage
of element or accessory)
Accessories and Optical Controls (pp. 326-339)
Cable (p. 290)
Turnbuckles (one pair for each end; p. 291)
Transformer (pp. 294, 296)
Power Feed Canopy (for remote transformer; p. 295)
Isolating Connectors (if necessary; p. 293)
Ceiling or wall supports (if necessary; pp. 292-293)
Make sure all finishes match and item numbers end with C (Chrome) or S (Satin nickel)
www.techlighting.com
19
MONORAIL SYSTEM
Remote Transformer
4“ Round Power Feed Canopy
Power Extender
End Caps
Rigid Standoff
Mini Mission Pendant
End Caps
Adler Head
Little Pleat
Glass Shield
MR16 Lamp
www.wilmettelighting.com
20
MONORAIL SYSTEM
Step One: Design Your Wilmette MonoRail System
Page numbers below reference the Wilmette Full-Line
Catalog (921WMTFLCAT09), unless indicated otherwise
QTY.
L O W - V O LT A G E H E A D S & P E N D A N T S :
Choose low-voltage heads & pendants from system
thumbnails (p. 137) .
Determine item number(s) (pp. 84-129).
ITEM NUMBER
600MO __________________
600MO
700MO __________________
________________
600MO __________________
Choose Accessories and Optical Controls, if required or desired
(pp. 84-129).
Determine item number(s) (pp. 130-131).
600 ______________________
700 ______________________
___________________
600
700 ___________________
Choose lamps that do not exceed maximum wattage
of low-voltage head or pendant or accessory
(may be included; pp. 84-129).
Determine item number(s) (p. 156).
300BLV
300BLV __________________
________________
300BLV __________________
300BLV ________________
Add up total lamp wattage on system.
________ watts watts
_____________
FINISH:
Choose finish of system and make sure all components
are specified as such
(( C
Z )) ACNHTRIOQM
U EE B R O N Z E
(N) POLISHED NICKEL
( S ) S AT I N N I C K E L
DRAWING:
Use scaled drawing as a reference.
LENGTH:
Measure length of MonoRail run; determine quantity
and length of MonoRail pieces required (p. 140).
600MOA _________________
700MOA ______________
600MOA _________________
Specify one pair of End Caps for each open end of run (p. 141).
700MOA ______________
700MOCCAP ______________
_________
600MOCCAP
Determine number of Standoffs, one for every three feet of run.
___________
# of standoffs ______________
Does the run include a sharp angle or turn?
If so, specify a Flexible Connector to make the turn (p. 141).
700MOCFXH __________
600MOCFXH_______________
Would you like the Rail to be custom bent at the factory? If so, please
provide the degree and radius of each curve by fax to the quotes
department, 847.410.4720, for a quotation.
www.techlighting.com
21
MONORAIL SYSTEM
Step Two: Add Power and Hardware to Complete the System
QTY.
ITEM NUMBER
T R A N S F O R M E R **:
Remote Transformer (p. 142)
Choose:
Magnetic or electronic
*Output wattage _________
Single or dual-feed
600AT ________________
AND
AND
Specify a Power Feed Canopy, single or dual-feed (p. 142).
600MOP ______________
OR
OR
Surface Transformer (p. 143)
Choose:
Magnetic or electronic
*Output wattage _________
Single or dual-feed
600MO _______________
*Wattage of the transformer must meet or exceed wattage of lamps calculated on previous page.
**If you are using LED heads or pendants, be sure to choose a transformer that is compatible with LED fixtures.
If powering system with more than one Transformer, add
Isolating Connectors (p. 141) to isolate the power feeds
from each other.
600MOCINC
If dropping system a distance below ceiling, add one
Power Extender (p. 142) to each power feed
(add two when using dual-feed).
600MOP _______________
MOUNTING:
Select Standoffs (p. 141) that match or exceed drop of the
Surface Transformer or Power Feed. Refer to Length section
on previous page for quantity.
600MOS _______________
Is the ceiling vaulted? If so, specify one Power Vault Adapter (p. 144)
for each power feed (add two when using dual-feed).
Then specify one Standoff Vault Adapter for each Standoff (p. 144).
600MOPVLT ____________
600MOSVLT ____________
SPECIAL:
This outline covers only the most common MonoRail applications, but
MonoRail can do almost anything. For other MonoRail system options,
see pp. 144-145 of the catalog, or call your local representative or
Wilmette Lighting quotes department (800.522.5315).
www.wilmettelighting.com
22
MONORAIL SYSTEM
SAMPLE BILL OF MATERIALS - As seen on p. 124 of the Wilmette Full Line Catalog
F
H
D
E
G
A
B
A
H
C
E
B
A
A
A
C
C
C
B
B
B
C
Item
Quantity
A
B
C
D
E
F
G
H
5
5
5
1
2
1
1
2
Item Number
Description
600MOSVN06N
600LIPLTA
300BLV139
600MOBHSC60N
600MOCCAPN
600AT300T
600MOP4C02N
600MOS02N
WMT MO Sullivan Head 6", Polished Nickel
Little Pleat Accessory, Amber
12v CC Hal MR16, GU5.3 40˚ 50w
Clear MonoRail Horizontal S Curve, Polished Nickel
WMT MO End Caps, Pair, Polished Nickel
Remote Magnetic Transformer, 12v 300w
WMT MO Single Feed Canopy, 4" Round, Polished Nickel
WMT MO Rigid Standoffs, 2", Polished Nickel
CHECKLIST
Make sure your Bill of Materials Includes:
Transformer (pp. 142-143)
Power Feed Canopy (for remote transformer; p. 142)
Power Extender (if necessary; p. 142)
Isolating Connectors (if necessary; p. 141)
Standoffs—one for every three feet of run (p. 141, standoff lengths must match power feed length)
MonoRail (p. 140)
End Caps (one pair for each open end; p. 141)
Low-Voltage Heads & Pendants (pp. 84-129)
Accessories and Optical Controls (pp. 130-131)
Lamps—if not included with low-voltage heads and pendants (p. 156, lamps must not exceed
maximum wattage of element or accessory)
Make sure all finishes match and item numbers end with Z (Antique Bronze), N (Polished Nickel)
or S (Satin Nickel)
www.techlighting.com
23
T~TRAK SYSTEM
www.ttraklighting.com
24
T~TRAK SYSTEM
Step One: Design Your T~trak System
Page numbers below reference the T~trak Full-Line
Catalog (921TTFLCAT07), unless indicated otherwise.
Choose Single or Two-Circuit T~trak and make sure all
components are specified as such (TT Single-Circuit T~trak)
(TT2 Two-Circuit T~trak).
QTY.
ITEM NUMBER
E L E M E N T S (Pendants and Heads):
Choose elements from product overview (pp. 16-19).
Determine item number(s) for line-voltage elements (pp. 44-98).
Choose Accessories and Optical Controls, if desired
(pp. 66-67 & pp. 75, 77).
700TT __________________
700TT __________________
700TT __________________
700TT __________________
700 ____________________
700 ____________________
700 __________________
Determine item number(s) for low-voltage FreeJack elements
(pp. 28-129 of Tech Full Line Catalog).
700FJ __________________
Order one T~trak FreeJack connector for each FreeJack low-voltage
element (p. 18).
700TTCHEDFJ____________
Choose Accessories and Optical Controls, if required or desired
(pp. 226-233 of Tech Full Line Catalog).
700 ____________________
Determine item number(s) (pp. 226-233).
700 ____________________
700 __________________
Choose lamps that do not exceed maximum wattage of element
or accessory (may be included; pp. 44-98 line-voltage;
pp. 28-129 low-voltage).
300 ____________________
Determine item number(s) (pp. 105-106, also pp. 234-236
of Tech Full Line Catalog).
300 ____________________
300 ____________________
300 ____________________
FINISH:
(Z)
Choose finish of system and make sure all components
are specified as such.
ANTIQUE BRONZE
(SELECTED FIXTURES)
ATI N
I NNNI CI CKKE EL LO N LY
( S ) S SAT
(W) WHITE
DRAWING:
Use scaled drawing as a reference.
LENGTH:
Measure length of T~trak run; determine quantity and length
of T~trak pieces required (p. 20).
_________________
700TTA _____________
700TTA _____________
700TTA _________________
Determine number of Rigid Standoffs with Connector, one for each
connection point between track sections.
# of standoffs ____________
with
with
connector
connector
_______________
Determine number of Rigid Standoffs without Connector, one for the
center of each 8' track section plus two for the ends of the run.
of standoffs
standoffs ____________
without
## of
connector _______________
Does the run include a sharp angle or turn?
If so, specify a Flexible Connector to make the turn (p. 21) and add
2 Rigid Standoffs without Connector (above).
Would you like the track to be custom bent at the factory? If so,
please provide the degree and radius of each curve by fax to the
quotes department, 847.410.4720, for a quotation.
www.techlighting.com
700TTCFXHS
25
T~TRAK SYSTEM
Step Two: Add Power and Hardware to Complete the System
QTY.
ITEM NUMBER
P O W E R F E E D C A N O P Y:
Determine how far below the ceiling the system will be dropped.
Power Feed Canopy (p. 22)
Choose:
Type of Power Feed
Length of Drop
700TTP _______________
If using a Power Feed Canopy “with connector” you can reduce
your standoff with connector count (on previous page) by one.
MOUNTING:
Select Rigid Standoffs with Connector (p. 21) that match the
drop of the Power Feed Canopy. Refer to Length section on
previous page for quantity.
700TTSCC _____________
Select Rigid Standoffs without Connector (p. 21) that match the
drop of the Power Feed Canopy. Refer to Length section on
previous page for quantity.
700TTS _______________
________________
Is the ceiling vaulted? If so specify one Power Vault Adapter (p. 24)
for each Power Feed Canopy.
Then specify one Standoff Vault Adapter for each Standoff (p. 24).
700TTPVLTS ___________
___________
700TTSVLTS
___________
____________
SPECIAL:
This outline covers only the most common T~trak™ applications, but
T~trak can do almost anything. For other system options, see Special
Installations on (pp. 24-25) of the catalog, or call your local representative
or Tech Lighting quotes department (800.522.5315).
www.ttraklighting.com
26
T~TRAK SYSTEM
SAMPLE BILL OF MATERIALS - As seen on p. 79 of the T~trak Full Line Catalog
F
F
E
C
F
D
B
B
Item
A
B
C
D
E
F
A
A
A
B
B
A
Quantity
4
4
2
1
1
3
Item Number
700TTOM2006FW
300BHV417
700TTA96W
700TTP4C02W
700TTSCC02W
700TTS02W
Description
TT-Om PAR20 6", Frost Lens Ring, White
120v Inc PAR20 E26 Med 40˚ 50w
T~trak 96", White
TT Power Feed Canopy w/o Connector, 4" Round, 2", White
TT Rigid Standoff w/ Conductive Connector 2", White
TT Rigid Standoff w/o Connector 2", White
CHECKLIST
Make sure your Bill of Materials Includes:
Power Feed Canopy (p. 22, without connector if powering from the center of a section of track; with
connector if joining sections of track)
Standoffs with Connector (p. 21, one for each connection point between track sections)
Standoffs without Connector (p. 21, one for the center of each 8' track section plus two for the ends
of the run)
T~trak (p. 20)
Elements—line-voltage (pp. 44-98)
Elements—low-voltage; order one T~trak FreeJack connector (p. 18) for each FreeJack element (pp. 28-129
of Tech Full Line Catalog)
Accessories and Optical Controls (pp. 66-67, 75, 77 line-voltage; pp. 226-233 of Tech Full Line Catalog,
low-voltage) (pp. 28-129 of Tech Full Line Catalog)
Lamps—if not included with elements; (pp. 105-106, also pp. 234-236 of Tech Full Line Catalog), lamps
must not exceed maximum wattage of element or accessory)
Make sure all finishes match and item numbers end with (Z) Antique Bronze, (S) Satin Nickel or (W) White
End Caps (one pair for each open end; p. 21)
www.techlighting.com
27
L AY O U T W O R K S H E E T
847.410.4400
Quotes Dept. Fax:
847.410.4720
www.encompasslighting.com
Date ____________________
Rep _______________________________________________
Job name/location _____________________________________________________________
Submitter’s name ______________________________________________________________
Company ____________________________________________________________________
Phone _________________________________ Fax _________________________________
SYSTEM
Tech Lighting MonoRail (p. 234)
Tech Lighting Two-Circuit MonoRail
Tech Lighting Wall MonoRail (p. 270) Tech Lighting Kable Lite (p. 284)
T~trak (p. 6)
(p. 254)
™
Note:pages numbers refer to their respective catalogs
ELEMENTS
Elements to be used (specify):
Name / Length
Quantity
Color/Finish
Accessory/Finish/Color
Lamp/Watts
1st Type
2nd Type
3rd Type
4th Type
Total No. of Elements:
Total Wattage:
FINISH
Antique Bronze
Chrome
Satin Nickel
White T~trak only
Custom finish or colored insulator (specify) ________________________________________________
DRAWING
Attach scaled drawing or provide on reverse side.
Plan view
Elevation
LENGTH
Scale:
1/8" = 1'
1/2" = 1'
1/4" = 1'
Not to scale
Length of run:
If custom curve, supply degree and radius:
TRANSFORMER
(low-voltage systems only)
Remote:
(p. 270)
Magnetic OR
Electronic
12V
24V
Output Wattage:
Canopy/Power Feed type:
4" Round
Direct End
2" Square
Other___________
Rectangular
Surface:
Magnetic OR
Electronic
12V 24V
Output Wattage:
If using existing junction boxes, show location on drawing.
MOUNTING
If ceiling mounted, how far below the ceiling will the system be dropped? (circle)
Tech Lighting MonoRail:
2"
Tech Lighting Two-Circuit MonoRail: 2"
SPECIAL
3"
4"
5"
6"
12"
24"
96"
36"
48"
96"
6"
12"
24"
36"
48"
Tech Lighting Kable Lite:
1"
2.5"
5"
12"
18"
24"
T~trak:
2"
6"
12"
24"
36"
48"
Is the ceiling vaulted?
Yes
Cantilever
Other (specify) _________________________________________
96"
No
28
L AY O U T W O R K S H E E T
847.410.4400
Quotes Dept. Fax:
847.410.4720
www.wilmettelighting.com
Date ____________________
Rep _______________________________________________
Job name/location _____________________________________________________________
Submitter’s name ______________________________________________________________
Company ____________________________________________________________________
Phone _________________________________ Fax _________________________________
SYSTEM
Wilmette MonoRail
ELEMENTS
Elements to be used (specify):
(p. 132)
Name / Length
Quantity
Color/Finish
Accessory/Finish/Color
Lamp/Watts
1st Type
2nd Type
3rd Type
4th Type
Total No. of Elements:
Total Wattage:
FINISH
Antique Bronze
Polished Nickel
Satin Nickel
Custom finish or colored insulator (specify) ________________________________________________
DRAWING
Attach scaled drawing or provide on reverse side.
Plan view
Elevation
LENGTH
1/8" = 1'
1/2" = 1'
Scale:
1/4" = 1'
Not to scale
Length of run:
If custom curve, supply degree and radius:
TRANSFORMER
(low-voltage systems only)
Remote:
Magnetic OR
Electronic
(p. 270)
Output Wattage:
Canopy/Power Feed type:
4" Round
Direct End
Other___________
Surface:
Magnetic OR
Electronic
Output Wattage:
If using existing junction boxes, show location on drawing.
MOUNTING
If ceiling mounted, how far below the ceiling will the system be dropped? (circle)
Wilmette MonoRail:
Is the ceiling vaulted?
SPECIAL
2"
3"
Yes
4"
5"
6"
12"
24"
36"
48"
96"
No
Other (specify) _________________________________________
29