MedLite C6 Product Brochure
Transcription
MedLite C6 Product Brochure
MedLite C 6 ® The legacy behind Q-switched technology A Booming Market Laser treatment of tattoos and pigmented lesions will expand with aging populations in the U.S, Asia and Europe5. Worldwide procedure volume is expected to reach 7.5 million in 2017, generating $1.3 billion in fees6. MedLite C6 Q-Switched Nd:YAG laser features proven PhotoAcoustic technology and multiple wavelengths for efficient, reproducible treatment on all patient skin types. •Tattoo Removal – Full Color Spectrum •Epidermal and Dermal Pigmented Lesions -- Nevus of Ota -- Sun Damage •Skin Resurfacing -- Wrinkle Reduction -- Acne Scar Reduction •Vascular Lesion Removal •Hair Removal – Fine Vellus Hair PhotoAcoustic Technology Flat-Top Beam Profile The hallmark of PhotoAcoustic PhotoAcoustic technology is technology is high peak power delivered through MedLite C6’s and short pulse duration. This homogenous, flat-top beam combination generates a profile, without spikes or hot spots. photomechanical or PhotoAcoustic As a result, energy is distributed action against the target evenly from the perimeter to the chromophore – whether it’s tattoo center of the beam, resulting in ink, pigment or collagen. The better fragmentation of the target electro-optic (EO) Q-Switch, acting chromophores with minimal to no as a high-speed shutter, stores epidermal injury. energy between pulses enabling the laser to produce peak power output of 200 megawatts in 5-20 nanosecond pulse widths. The MedLite C6 forces energy at such a high rate, the target chromophores vibrate and shatter, without harming the surrounding skin. 1200mj Proven Reliablility Built on ConBio’s original Q-switched technology, MedLite C6 is best known as the industry’s gold standard laser for epidermal and dermal pigmented lesion and multi-colored tattoo removal. It also provides a wide range of effective treatment applications, regardless of patient skin type. Anti-Aging Maintenance MedLite C6’s Q-Switched Nd:YAG technology can help resurface the skin through collagen stimulation.7 Epidermal and Dermal Pigmented Lesions MedLite C6 is ideal for treating a wide variety of pigmented lesions including age spots, solar lentigines, café-au-lait lesions and dermal melanocytosis, including Nevus of Ota and Hori’s Nevus. Non-Ablative Skin Resurfacing (Wrinkle/Acne Scar Reduction) The Q-Switched 1064nm wavelength reduces acne scars and wrinkles with minimal to no downtime or discomfort. Four wavelengths… Multiple Applications Depth of Penetration in the Skin Wavelength (nm) 532 585 650 1064 Epiderma Advanced Tattoo Removal Derma 1064nm targets dark ink 532nm targets red 585nm targets sky blue Hypoderma 650nm targets green Absorption Spectrum Absorption Spectrum for Melanin and Hemoglobin Oxyhemoglobin Absorption Melanin Absorption 532nm YAG 500 1064nm YAG 600 700 800 900 1000 Optional Features MultiLite Dye Handpieces extend the wavelength capabilities of the laser to include 585nm (yellow) and 650nm (red) for the treatment of tattoos, and pigmented and vascular lesions. Before After 8 Tx1 Courtesy of Niwat Polnikorn, MD, Kasemrad Aesthetics Center, Prachacheun, Thailand Before After Multiple Tx2 Courtesy of Bruce Saal, MD, Los Gatos, CA Before After 9 Tx3 Courtesy of Tran Thi Anh Tu, MD Cosmetic & Laser Surgery Clinic, HCMC, Vietnam Before After 1 Tx4 Courtesy of Hak Chul Shin, MD Dr. Shin’s Skin & Laser Clinic, Seoul, Korea Tattoo Removal & Pigmented Lesion Workstation System Type Wavelength Nd:YAG 1064 nm Pulse Width 532 nm Dye Impregnated Polymers 585 nm* 5 - 20 nsec 650 nm* <7 nsec Maximum Fluence per Spot Size (J/cm2) 8mm2.0 – – – 6mm3.5 1.4 – – 4mm8.0 3.2 – – 3mm12.0 2mm– Maximum Rep Rate 5.0 – 5.0 8.0 10 HZ Electrical Requirements – 4.5 2 HZ 1 HZ 220 V, single phase, 8 Amp or 110 V, Single Phase, 15 Amps Aiming Beam Red Size (H x W x D) 113 cm x 30.5 cm x 72.5 cm Weight 58 kg *Optional Handpieces SOURCES 1 Parameters: 1064nm, 6mm spot size, 2.5J/cm2; 1st 4 Tx - every 2 weeks; last 4 Tx - once a month. 2 Parameters: 1064nm, 6mm spot size, 3.5J/cm2 3 Parameters: 1064nm, 6mm spot size, 3.5J/cm2 4 Parameters: 1064nm, 3mm spot size, 7.7J/cm2 5 Medical Insight, Inc. January 2013 6 Medical Insight, Inc. January 2013 7 Liu, H., MD, PhD, Dang, Y., PhD et al. (2008). Laser induced collagen remodeling: A comparative study in vivo on mouse model. Lasers in Surgery and Medicine 40:B-19 HEADQUARTERS CORPORATE HEADQUARTERS United States ConBio, Inc. 47733 Fremont Boulevard Fremont, CA 94538 510.445.4570 United States Cynosure, Inc. 5 Carlisle Road Westford, MA 01886 978.256.4200 www.conbio.com www.cynosure.com CAUTION - CLASS 4 VISIBLE AND INVISIBLE LASER RADIATION WHEN OPEN. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION. CAUTION - CLASS 4 ENERGY: 1 J MAX PULSE WIDTH: < 20 ns WAVELENGTH: 1064, 532 nm 650, 585 nm PULSE WIDTH: < 20 ns WAVELENGTH: 1064, 532 nm AIMING BEAM: 650nm < 1mw cw 650, 585 nm AIMING BEAM: 650nm < 1mw cw IEC60825-1: 2007 VISIBLE AND INVISIBLE LASER RADIATION WHEN OPEN. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION. ENERGY: 1 J MAX IEC60825-1 : 2007 For OUS use only MedLite C6 and Cynosure are registered trademarks of Cynosure, Inc. ConBio is a trademark of Cynosure, Inc. ©2013 Cynosure, Inc. 921-0268-000 Rev 2 2/13
Similar documents
The legacy behind Q-switched technology
MedLite C6 Q-Switched Nd:YAG laser features proven PhotoAcoustic technology and multiple wavelengths for efficient, reproducible treatment on all patient skin types. • Tattoo Removal – Full Color ...
More informationThe Short Pulse Laser Evolution
*Compared to MedLite® C6 | 1. D. Yaghmai, MD, J. Garden, MD, A. Bakus, PhD, M. Gold, MD, B. Saal, MD, D. Goldberg, MD and M. Massa, MD. Photodamage therapy using an electro-optic Q-Switched Nd:YAG ...
More informationa gold standard in Q-Switched technology
ENERGY: 1 J MAX PULSE WIDTH: < 20 ns WAVELENGTH: 1064, 532 nm 650, 585 nm AIMING BEAM: 650nm < 1mw cw IEC60825-1: 2007