Swisslog`s TransLogic pneumatic tube systems transport carriers
Transcription
Swisslog`s TransLogic pneumatic tube systems transport carriers
Pneumatic Tube System Accessories SWISSLOG SPECIFICATIONS TRANSMISSION COMPONENTS FOR TRANSLOGIC PNEUMATIC TUBE SYSTEMS The remote arrival indicator (RAI) notifies users that a carrier has arrived by flashing a yellow light and/or by sounding a chime. Both the light and chime are turned off by pressing the reset button on the indicator. The RAI can be installed adjacent to a station or in a remote location. The carrier storage unit provides ample and convenient storage for Universal and Eco-Seal™ carriers. The carrier storage unit stores up to 39 4-inch carriers or up to 16 6-inch carriers. A remote personal indicator acts as a virtual station and has its own system address. These will light/sound only when a carrier is directed to the specific address assigned to the indicator. This allows multiple groups of users to effectively share a single PTS station. Remote personal indicators may be installed adjacent to the station or at a remote location. Up to six unique personal indicator addresses may be assigned to each PTS station. For More Information in North America: Swisslog Healthcare Solutions Email: [email protected] USA: 800.764.0300 Canada: 877.294-2831 | 905.629.2400 12.375" (31.5 cm) 13.625" (34.5 cm) 17" (43.25 cm) 51.5" (131 cm) 66.375" (168.5 cm) 11.75" (30 cm) SwisslogHealthcareSolutions 50" (127 cm) 15.625" (39.75 cm) SwisslogNA WWW.SWISSLOG.COM ©2011 Swisslog CM# PTS-201 Remote Personal Indicators Indicators can also be configured as virtual stations called remote personal indicators. The carrier storage unit has a carpeted interior and is installed flush-mounted into a finished wall - requiring no additional floor space. Swisslog’s TransLogic pneumatic tube systems transport carriers using intricate paths of galvanized steel tubing hidden behind walls and above the ceilings in hospitals and between buildings. Blower units provide air pressure and vacuum to move the carriers to their destination, while transfer units direct carriers to the correct tube paths. Galvanized Steel Tubing Pneumatic tube system (PTS) galvanized steel tubing consists of straight tubing, bends, couplings and assorted fittings used to construct the carrier distribution network. Tubing and bends are 16-gauge galvanized steel, available in 4-inch O.D. and 6-inch O.D. Bends Partial bends and 90 degree bends are used to change the direction of tubing. Maximum Specifications 6-inch 4-inch 4.5" (11.43 cm) 3" (7.62 cm) Carrier Storage Unit 65.62" (166.67 cm) 64.25" (163.20 cm) Remote Arrival Indicators 50" (127 cm) 50" (127 cm) 70" (177.8 cm) 69.25" (175.90 cm) 6" (15.25 cm) 4" (10.16 cm) Joint Components Three types of joints are used throughout the tubing network: the expanded-end joint, drive sleeve and bolted coupling. The standard joint is a slip socket type. The tubing expanded-ends have a patented design that provides the smoothest possible transition for a carrier and minimizes noise and carrier wear. Cut tubing ends are joined with either a drive sleeve or a bolted coupling. Joints at major components (stations and transfer units) are usually made with a bolted coupling. Tube Hangers Tube hangers are used to suspend pneumatic tubing from the structure. Both tear drop hangers and strut support hangers mount to 1-5/8” channel. 5" 12.7 cm 3 1/2" 8.89 cm 2 1/2" 6.35 cm 5" 12.7 cm 3 1/4" 8.26 cm 4" Dia. 10.16 cm 28" 71.12 cm 28" 71.12 cm 6 5/16" 15.88 cm 6" 15.24 cm Front Top 6" 15.24 cm 5 5/16" 115 VAC 13.34 cmPower Conduit Entrance 7 1/4" / 18.42 cm 30" 76.2 cm 6" 15.24 cm 5 1/4" 13.34 cm 22 1/2" 57.15 cm Transfer Unit Right Side 3 1/4" 8.23 cm 8 1/4" 20.96 cm Comm Cable Entrance 9/16" Dia. Holes for Sway Braces (4) 1.27 cm 9/16" Dia. Mounting Holes (4) Blower Unit The blower unit provides vacuum and pressure to 3 1/4" 8.26 cm move carriers at consistent speeds regardless of payload or proximity to the blower. The unit consists 28" 71.12 cm for of a heavy-duty regenerative blower motor rated continuous duty and a shifter valve mechanism used 30" 76.2 cm to connect either vacuum or pressure to the system piping as required. Blowers are offered in both 4 and 6 inch versions and can also be optionally equipped with a variable frequency drive (VFD). VFD equipped models provide software control of the blower speed enabling transport of sensitive items at slower speeds and empty carriers at faster speeds. 5" 12.7 cm 3 1/4" 28" 8.26 cm 28" 71.12 cm 6 5/16" 34 1/2" 71.12 cm 3 1/2" 15.88 5" 87.63 cmcm 8.89 cm 12.7 cm 6" 12 1/2" 15.24 cm 31.75 cm 4" 28" 10.16 cm 71.12 cm Top 7 1/4" / 18.42 cm Top 230/460 VAC Power 30" Conduit Entrance 76.2 cm (Enclosed Models Only) Front 27" 6" 68.58 cm 15.24 cm Left Side 1" 2.54 cm 5 1/4" 13.34 cm 2 1/2" 6.35 cm 6 5/16" 8 1/2" 15.88 cm 21.59 cm 6" 6" 15.24 cm 15.24 cm 4" Dia. 10.16 cm 5 5/16" 3 9/16" 8.89 13.34 cm cm 5 5/16" 13.34 cm 7 1/4" / 18.42 cm 3 1/4" 8.23 cm 6" 15.24 cm Screen Box 13 3/16" 33.66 cm 3 1/4" 8.23 cm 3 9/16" 8.89 cm 5" 12.7 cm 22 1/2" 9/16" Dia. Mounting 57.15 cmHoles (4) 2 1/2" 6.35 cm 5" 12.7 cm Right Side 8 1/4" 20.96 cm Starter/VFD Access Cover (Enclosed Models Only) 8 1/4" 20.96 cm 9/16" Dia. Mounting Holes (4) Comm Cable Entrance 2 1/2" 6.35 cm 5" 12.7 cm 5" The blower unit is an open-frame design and is38.891/2"cm 12.7 cm suitable for installation in areas such as mechanical 34 1/2" 87.63 cm 12 1/2" equipment rooms. A sound attenuated model 31.75 cm 4" completely enclosed in a sheet metal housing with 10.16 cm Front Front sound absorbing lining and equipped with mufflers is 230/460 VAC Power Conduit Entrance (Enclosed Models Only) also available. The sound attenuated version permits 27" 68.58 cm installation near occupied areas. Both models use 5 1/4" Left Side 22 1/2" 5 1/4" 13.34 cm blower motor isolation mounts, insulating vibrations 22 1/2" 57.15 cm 13.34 cm 57.15 cm 1" 9/16" Dia. Holes for Sway Braces (4) 2.54 cm from the structure. To conserve energy, the blower9/16" is Dia. Holes for Sway Braces1.27 (4) cm 1.27 cm automatically turned off during periods of inactivity. 4" Dia. 10.16 cm 4" Dia. 10.16 cm 8 1/2" 21.59 cm 115 VAC Power Conduit Entrance Right 3 9/16" Side 8.89 cm 115 VAC Power Conduit Entrance 13 3/16" 33.66 cm Right Side 3 9/16" 8.89 cm Specifications Drive Mechanism: Electromechanical Power Requirements: 105 to 125 VAC, 60 Hz, Single Phase, 3A The entire transfer unit is enclosed in a rigid metal box frame with removable side covers for service. The simple design and heavy-duty construction provide very high reliability. Diagnostic features such as a built-in port alignment gauge, and diagnostic switches and indicators on the control assembly simplify maintenance. A port cap is used to cover an unused line from a transfer unit. Control Requirements: 4 conductor cable, #22 AWG stranded, 5 VDC maximum open circuit voltage, 200 mA maximum short circuit current Starter/VFD Access Cover Comm Cable (Enclosed Models Only)Entrance 1x4 Comm Cable Entrance Environmental Requirements: Temperature Operating0° to8 1/2" 120° F (5° to 49° C) 34 1/2" 8 1/2"87.63 cm 21.59 cm 12 1/2" 21.59 cm Storage Temperature-20° to 180° F (29° to 82° C) Blower Type: Regenerative 12 1/2" 31.75 cm 31.75 cm 3 9/16" 4" Relative 0 to3 9/16" 90% 8.89 cm 4" 10.16 cm Humidity 8.89 cm 10.16 cm 13 3/16" Maximum Operating RPM 3500 Power Requirements: 13 3/16" 33.66 cm 230/460 VAC Power 33.66 cm 230/460 VAC Power Conduit Entrance 4-inch6-inch 3 9/16" Conduit Entrance (Enclosed Models Only) Shifter Valve Motor: 105-125 VAC, 60 Hz, 1 Phase, 5.4(Enclosed A Models Only)27" 3 9/16" 8.89 cm 8.89 cm 27" 68.58 cm frame Open 240 lbs/109 kg 395 lbs/179 kg Blower Motor: 200-230, 460 VAC, 50/60 Hz, 3 Phase 68.58 cm Screen Box Screen Box Open frame (w/VFD) 250 lbs/113 kg 405 lbs/184 kg Horsepower* 200-230 VAC 460 VAC Left Side Left Side Starter/VFD Access Cover Sound Attenuated 375 lbs/170 kg 530 lbs/240 kg Starter/VFD Access Cover (Enclosed Models Only) 4-inch 4.2-4.5 4.5 1" 1" (Enclosed Models Only) 2.54 cm 2.54 cm Sound Attenuated (w/VFD) 385 lbs/175 kg 540 lbs/245 kg 6-inch 8.7-10 10 Heat output (approximately) 9000 BTU/hr 8000 BTU/hr Full Load Amperage* Sound levels 4-inch 12-11 5.5 In open area (open frame) 75 dbA 82 dbA 6-inch 26-23 11.5 In open area (attenuated) 61 dbA 72 dbA *Size all circuit protection in accordance with local, state, and national electrical codes. Mounted above ceiling** 51-55 dbA 61-66 dbA **Attenuated model only - sound measurement 3 feet below ceiling Control Requirements: 4 conductor cable, #22 AWG stranded, 5 VDC maximum open circuit voltage, 200 mA maximum short circuity current 1x6 System 4-inch 6-inch Weight 205 lbs 93.0 kg 250 lbs 113.4 kg 1x2 Environmental Requirements: Temperature Operating: 0° to 120° F (5° to 49° C)) Storage Temperature: -20° to 180° F (29° to 82° C) Relative Humidity: 0 to 90% Max. System Vacuum/Pressure: 4 psig Positioning Time: Typically 2 sec. (3 sec. max) Heat Output: Approx. 130 BTU/hr Access Cover Screen Box 34 1/2" 87.63 cm Max. vacuum/pressure at 5000 ft / 1.5 km: 3.5 psig Max. output at zero pressure and 500 ft / 152.4 m: 165 SCFM for 4-inch / 330 SCFM for 6-inch 115 VAC Power Conduit Entrance 9/16" Dia. Holes for Sway Braces (4) 1.27 cm 3 1/2" 8.89 cm Specifications 6" 15.24 cm The transfer unit is a switching device used at branching points in the system to direct the path of a carrier from a single pipe at one end to any one of two, four, or six selectable pipes at the other end. An optical sensor is contained within each unit to detect the passage of a carrier. A moveable tube gently guides the carrier through the unit in either direction. The tube is positioned precisely at the selected port by a magnetic proximity sensor. 0 1 2 3 Access Cover F C E E D B A System WeightA B C D E F 4-inch 145 lbs 50 1/2”44 3/4”18” 18” 6 5/8”13 5/8” 65.7 kg 128.3 cm 113.7 cm 45.7 cm 45.7 cm 16.5 cm 34.9 cm 6-inch 185 lbs 52 7/8”47 1/4”21 1/2”21 1/2”8” 17” 83.9 kg 134.4 cm 120 cm 54.6 cm 54.61 cm 20.3 cm 43.2 cm 6-inch 95 lbs 44” 34 3/4 “18 7/8”18 7/8”8” 13” Mini 43.1 kg 111.8 cm 88.3 cm 48 cm 48 cm 20.3 cm 33 cm F System DWeight 4-inch 145 lbs G H 65.7 kg A 50-1/2" 128.3 cm B 44-3/4" 113.7 cm D AC 17-3/4" 17-3/4" B Access Cover 45.1 cm 45.1 cm E 6-5/8" 16.5 cm F 13-5/8" 34.9 cm 6-inch 52-7/8" 134.4 cm 47-1/4" 120.0 cm 21-1/2" 54.6 cm 8" 20.3 cm 17" 43.2 cm 185 lbs 83.9 kg 21-1/2" 54.61 cm C E I A B C D E F G H I 53 3/4”48 3/4”19 3/4”20 11/16”10 11/16”4 5/16”10 5/16”4 5/8”5 5/16” 136.5 cm 123.8 cm 50.2 cm 52.8 cm 27.4 cm 11.4 cm 26.0 cm 11.5 cm 13.9 cm 58 7/8”53 11/16”24 1/2”26 5/8”14 5/8”4 15/16”13 1/8”6 5/16”7 5/8” 149.4 cm 136.5 cm 62.2 cm 67.6 cm 37.2 cm 12.7 cm 33.3 cm 15.9 cm 19.3 cm System Weight A AB 4-inch 205 lbs 53-3/4" 48-3/4" B cm 93.0 kg 136.5 cm 123.8 6-inch 250 lbs 58-7/8" 53-11/16" E 113.4 kg 149.4 cm 136.5 cm SystemWeight A B 4-inch 125 lbs 43” 38” 56.7 kg 109.2 cm 96.5 cm 6-inch 165 lbs 47” 42” 74.8 kg 119.4 cm 106.7 cm C D E AccessFCover G 19-1/2" 20-11/16" 10-11/16" 4-5/16" 10 5/16" 49.5 cm 52.8 cm 27.4 cm 11.4 cm 26.0 cm 24-3/8" 26-7/16" 11-1/8" 4-15/16" 13-1/8" 62.2 cm 67.3 cm 28.2 cm 12.7 cm 33.3 cm H 4-5/8" 11.5 cm 6-5/16" 15.9 cmG I 5-5/16" 13.9 cm K 7-1/2" 19.1 cm C H J F D C D E F G H J K 18 1/2” 8” 36 1/4”5 5/8”16” 5 1/2”3 3/4”12” 47.0 cm 20.3 cm 92.0 cm 14.0 cm 40.6 cm 14.0 cm 9.5 cm 30.5 cm 23 1/2”10 1/2”40 1/4”7 5/8”21” 8” 4 1/2”15 59.7 cm 26.7 cm 102.2 cm 19.0 cm 53.3 cm 20.3 cm 11.4 cm 38.1 cm 5" 12.7 cm 3 1/2" 8.89 cm 2 1/2" 6.35 cm 5" 12.7 cm 3 1/4" 8.26 cm 4" Dia. 10.16 cm 28" 71.12 cm 28" 71.12 cm 6 5/16" 15.88 cm 6" 15.24 cm Front Top 6" 15.24 cm 5 5/16" 115 VAC 13.34 cmPower Conduit Entrance 7 1/4" / 18.42 cm 30" 76.2 cm 6" 15.24 cm 5 1/4" 13.34 cm 22 1/2" 57.15 cm Transfer Unit Right Side 3 1/4" 8.23 cm 8 1/4" 20.96 cm Comm Cable Entrance 9/16" Dia. Holes for Sway Braces (4) 1.27 cm 9/16" Dia. Mounting Holes (4) Blower Unit The blower unit provides vacuum and pressure to 3 1/4" 8.26 cm move carriers at consistent speeds regardless of payload or proximity to the blower. The unit consists 28" 71.12 cm for of a heavy-duty regenerative blower motor rated continuous duty and a shifter valve mechanism used 30" 76.2 cm to connect either vacuum or pressure to the system piping as required. Blowers are offered in both 4 and 6 inch versions and can also be optionally equipped with a variable frequency drive (VFD). VFD equipped models provide software control of the blower speed enabling transport of sensitive items at slower speeds and empty carriers at faster speeds. 5" 12.7 cm 3 1/4" 28" 8.26 cm 28" 71.12 cm 6 5/16" 34 1/2" 71.12 cm 3 1/2" 15.88 5" 87.63 cmcm 8.89 cm 12.7 cm 6" 12 1/2" 15.24 cm 31.75 cm 4" 28" 10.16 cm 71.12 cm Top 7 1/4" / 18.42 cm Top 230/460 VAC Power 30" Conduit Entrance 76.2 cm (Enclosed Models Only) Front 27" 6" 68.58 cm 15.24 cm Left Side 1" 2.54 cm 5 1/4" 13.34 cm 2 1/2" 6.35 cm 6 5/16" 8 1/2" 15.88 cm 21.59 cm 6" 6" 15.24 cm 15.24 cm 4" Dia. 10.16 cm 5 5/16" 3 9/16" 8.89 13.34 cm cm 5 5/16" 13.34 cm 7 1/4" / 18.42 cm 3 1/4" 8.23 cm 6" 15.24 cm Screen Box 13 3/16" 33.66 cm 3 1/4" 8.23 cm 3 9/16" 8.89 cm 5" 12.7 cm 22 1/2" 9/16" Dia. Mounting 57.15 cmHoles (4) 2 1/2" 6.35 cm 5" 12.7 cm Right Side 8 1/4" 20.96 cm Starter/VFD Access Cover (Enclosed Models Only) 8 1/4" 20.96 cm 9/16" Dia. Mounting Holes (4) Comm Cable Entrance 2 1/2" 6.35 cm 5" 12.7 cm 5" The blower unit is an open-frame design and is38.891/2"cm 12.7 cm suitable for installation in areas such as mechanical 34 1/2" 87.63 cm 12 1/2" equipment rooms. A sound attenuated model 31.75 cm 4" completely enclosed in a sheet metal housing with 10.16 cm Front Front sound absorbing lining and equipped with mufflers is 230/460 VAC Power Conduit Entrance (Enclosed Models Only) also available. The sound attenuated version permits 27" 68.58 cm installation near occupied areas. Both models use 5 1/4" Left Side 22 1/2" 5 1/4" 13.34 cm blower motor isolation mounts, insulating vibrations 22 1/2" 57.15 cm 13.34 cm 57.15 cm 1" 9/16" Dia. Holes for Sway Braces (4) 2.54 cm from the structure. To conserve energy, the blower9/16" is Dia. Holes for Sway Braces1.27 (4) cm 1.27 cm automatically turned off during periods of inactivity. 4" Dia. 10.16 cm 4" Dia. 10.16 cm 8 1/2" 21.59 cm 115 VAC Power Conduit Entrance Right 3 9/16" Side 8.89 cm 115 VAC Power Conduit Entrance 13 3/16" 33.66 cm Right Side 3 9/16" 8.89 cm Specifications Drive Mechanism: Electromechanical Power Requirements: 105 to 125 VAC, 60 Hz, Single Phase, 3A The entire transfer unit is enclosed in a rigid metal box frame with removable side covers for service. The simple design and heavy-duty construction provide very high reliability. Diagnostic features such as a built-in port alignment gauge, and diagnostic switches and indicators on the control assembly simplify maintenance. A port cap is used to cover an unused line from a transfer unit. Control Requirements: 4 conductor cable, #22 AWG stranded, 5 VDC maximum open circuit voltage, 200 mA maximum short circuit current Starter/VFD Access Cover Comm Cable (Enclosed Models Only)Entrance 1x4 Comm Cable Entrance Environmental Requirements: Temperature Operating0° to8 1/2" 120° F (5° to 49° C) 34 1/2" 8 1/2"87.63 cm 21.59 cm 12 1/2" 21.59 cm Storage Temperature-20° to 180° F (29° to 82° C) Blower Type: Regenerative 12 1/2" 31.75 cm 31.75 cm 3 9/16" 4" Relative 0 to3 9/16" 90% 8.89 cm 4" 10.16 cm Humidity 8.89 cm 10.16 cm 13 3/16" Maximum Operating RPM 3500 Power Requirements: 13 3/16" 33.66 cm 230/460 VAC Power 33.66 cm 230/460 VAC Power Conduit Entrance 4-inch6-inch 3 9/16" Conduit Entrance (Enclosed Models Only) Shifter Valve Motor: 105-125 VAC, 60 Hz, 1 Phase, 5.4(Enclosed A Models Only)27" 3 9/16" 8.89 cm 8.89 cm 27" 68.58 cm frame Open 240 lbs/109 kg 395 lbs/179 kg Blower Motor: 200-230, 460 VAC, 50/60 Hz, 3 Phase 68.58 cm Screen Box Screen Box Open frame (w/VFD) 250 lbs/113 kg 405 lbs/184 kg Horsepower* 200-230 VAC 460 VAC Left Side Left Side Starter/VFD Access Cover Sound Attenuated 375 lbs/170 kg 530 lbs/240 kg Starter/VFD Access Cover (Enclosed Models Only) 4-inch 4.2-4.5 4.5 1" 1" (Enclosed Models Only) 2.54 cm 2.54 cm Sound Attenuated (w/VFD) 385 lbs/175 kg 540 lbs/245 kg 6-inch 8.7-10 10 Heat output (approximately) 9000 BTU/hr 8000 BTU/hr Full Load Amperage* Sound levels 4-inch 12-11 5.5 In open area (open frame) 75 dbA 82 dbA 6-inch 26-23 11.5 In open area (attenuated) 61 dbA 72 dbA *Size all circuit protection in accordance with local, state, and national electrical codes. Mounted above ceiling** 51-55 dbA 61-66 dbA **Attenuated model only - sound measurement 3 feet below ceiling Control Requirements: 4 conductor cable, #22 AWG stranded, 5 VDC maximum open circuit voltage, 200 mA maximum short circuity current 1x6 System 4-inch 6-inch Weight 205 lbs 93.0 kg 250 lbs 113.4 kg 1x2 Environmental Requirements: Temperature Operating: 0° to 120° F (5° to 49° C)) Storage Temperature: -20° to 180° F (29° to 82° C) Relative Humidity: 0 to 90% Max. System Vacuum/Pressure: 4 psig Positioning Time: Typically 2 sec. (3 sec. max) Heat Output: Approx. 130 BTU/hr Access Cover Screen Box 34 1/2" 87.63 cm Max. vacuum/pressure at 5000 ft / 1.5 km: 3.5 psig Max. output at zero pressure and 500 ft / 152.4 m: 165 SCFM for 4-inch / 330 SCFM for 6-inch 115 VAC Power Conduit Entrance 9/16" Dia. Holes for Sway Braces (4) 1.27 cm 3 1/2" 8.89 cm Specifications 6" 15.24 cm The transfer unit is a switching device used at branching points in the system to direct the path of a carrier from a single pipe at one end to any one of two, four, or six selectable pipes at the other end. An optical sensor is contained within each unit to detect the passage of a carrier. A moveable tube gently guides the carrier through the unit in either direction. The tube is positioned precisely at the selected port by a magnetic proximity sensor. 0 1 2 3 Access Cover F C E E D B A System WeightA B C D E F 4-inch 145 lbs 50 1/2”44 3/4”18” 18” 6 5/8”13 5/8” 65.7 kg 128.3 cm 113.7 cm 45.7 cm 45.7 cm 16.5 cm 34.9 cm 6-inch 185 lbs 52 7/8”47 1/4”21 1/2”21 1/2”8” 17” 83.9 kg 134.4 cm 120 cm 54.6 cm 54.61 cm 20.3 cm 43.2 cm 6-inch 95 lbs 44” 34 3/4 “18 7/8”18 7/8”8” 13” Mini 43.1 kg 111.8 cm 88.3 cm 48 cm 48 cm 20.3 cm 33 cm F System DWeight 4-inch 145 lbs G H 65.7 kg A 50-1/2" 128.3 cm B 44-3/4" 113.7 cm D AC 17-3/4" 17-3/4" B Access Cover 45.1 cm 45.1 cm E 6-5/8" 16.5 cm F 13-5/8" 34.9 cm 6-inch 52-7/8" 134.4 cm 47-1/4" 120.0 cm 21-1/2" 54.6 cm 8" 20.3 cm 17" 43.2 cm 185 lbs 83.9 kg 21-1/2" 54.61 cm C E I A B C D E F G H I 53 3/4”48 3/4”19 3/4”20 11/16”10 11/16”4 5/16”10 5/16”4 5/8”5 5/16” 136.5 cm 123.8 cm 50.2 cm 52.8 cm 27.4 cm 11.4 cm 26.0 cm 11.5 cm 13.9 cm 58 7/8”53 11/16”24 1/2”26 5/8”14 5/8”4 15/16”13 1/8”6 5/16”7 5/8” 149.4 cm 136.5 cm 62.2 cm 67.6 cm 37.2 cm 12.7 cm 33.3 cm 15.9 cm 19.3 cm System Weight A AB 4-inch 205 lbs 53-3/4" 48-3/4" B cm 93.0 kg 136.5 cm 123.8 6-inch 250 lbs 58-7/8" 53-11/16" E 113.4 kg 149.4 cm 136.5 cm SystemWeight A B 4-inch 125 lbs 43” 38” 56.7 kg 109.2 cm 96.5 cm 6-inch 165 lbs 47” 42” 74.8 kg 119.4 cm 106.7 cm C D E AccessFCover G 19-1/2" 20-11/16" 10-11/16" 4-5/16" 10 5/16" 49.5 cm 52.8 cm 27.4 cm 11.4 cm 26.0 cm 24-3/8" 26-7/16" 11-1/8" 4-15/16" 13-1/8" 62.2 cm 67.3 cm 28.2 cm 12.7 cm 33.3 cm H 4-5/8" 11.5 cm 6-5/16" 15.9 cmG I 5-5/16" 13.9 cm K 7-1/2" 19.1 cm C H J F D C D E F G H J K 18 1/2” 8” 36 1/4”5 5/8”16” 5 1/2”3 3/4”12” 47.0 cm 20.3 cm 92.0 cm 14.0 cm 40.6 cm 14.0 cm 9.5 cm 30.5 cm 23 1/2”10 1/2”40 1/4”7 5/8”21” 8” 4 1/2”15 59.7 cm 26.7 cm 102.2 cm 19.0 cm 53.3 cm 20.3 cm 11.4 cm 38.1 cm Pneumatic Tube System Accessories SWISSLOG SPECIFICATIONS TRANSMISSION COMPONENTS FOR TRANSLOGIC PNEUMATIC TUBE SYSTEMS The remote arrival indicator (RAI) notifies users that a carrier has arrived by flashing a yellow light and/or by sounding a chime. Both the light and chime are turned off by pressing the reset button on the indicator. The RAI can be installed adjacent to a station or in a remote location. The carrier storage unit provides ample and convenient storage for Universal and Eco-Seal™ carriers. The carrier storage unit stores up to 39 4-inch carriers or up to 16 6-inch carriers. A remote personal indicator acts as a virtual station and has its own system address. These will light/sound only when a carrier is directed to the specific address assigned to the indicator. This allows multiple groups of users to effectively share a single PTS station. Remote personal indicators may be installed adjacent to the station or at a remote location. Up to six unique personal indicator addresses may be assigned to each PTS station. For More Information in North America: Swisslog Healthcare Solutions Email: [email protected] USA: 800.764.0300 Canada: 877.294-2831 | 905.629.2400 12.375" (31.5 cm) 13.625" (34.5 cm) 17" (43.25 cm) 51.5" (131 cm) 66.375" (168.5 cm) 11.75" (30 cm) SwisslogHealthcareSolutions 50" (127 cm) 15.625" (39.75 cm) SwisslogNA WWW.SWISSLOG.COM ©2011 Swisslog CM# PTS-201 Remote Personal Indicators Indicators can also be configured as virtual stations called remote personal indicators. The carrier storage unit has a carpeted interior and is installed flush-mounted into a finished wall - requiring no additional floor space. Swisslog’s TransLogic pneumatic tube systems transport carriers using intricate paths of galvanized steel tubing hidden behind walls and above the ceilings in hospitals and between buildings. Blower units provide air pressure and vacuum to move the carriers to their destination, while transfer units direct carriers to the correct tube paths. Galvanized Steel Tubing Pneumatic tube system (PTS) galvanized steel tubing consists of straight tubing, bends, couplings and assorted fittings used to construct the carrier distribution network. Tubing and bends are 16-gauge galvanized steel, available in 4-inch O.D. and 6-inch O.D. Bends Partial bends and 90 degree bends are used to change the direction of tubing. Maximum Specifications 6-inch 4-inch 4.5" (11.43 cm) 3" (7.62 cm) Carrier Storage Unit 65.62" (166.67 cm) 64.25" (163.20 cm) Remote Arrival Indicators 50" (127 cm) 50" (127 cm) 70" (177.8 cm) 69.25" (175.90 cm) 6" (15.25 cm) 4" (10.16 cm) Joint Components Three types of joints are used throughout the tubing network: the expanded-end joint, drive sleeve and bolted coupling. The standard joint is a slip socket type. The tubing expanded-ends have a patented design that provides the smoothest possible transition for a carrier and minimizes noise and carrier wear. Cut tubing ends are joined with either a drive sleeve or a bolted coupling. Joints at major components (stations and transfer units) are usually made with a bolted coupling. Tube Hangers Tube hangers are used to suspend pneumatic tubing from the structure. Both tear drop hangers and strut support hangers mount to 13/16” channel.