Halton DTR

Transcription

Halton DTR
Halton reserves the right to alter products without notice
Halton DTR
Perforated Ceiling Diffuser
© Halton
•Horizontal air supply in four directions, also suitable
Accessories
for exhaust
•Deflector for the direction of flow pattern (up to
•Installation flush to the ceiling, low unit height
three directions)
•Available in sizes 300,450 and 600
•Balancing plenum with measurement and
•Size 600 adapted for installation in modular
adjustment functions
600x600 mm suspended ceiling
•Openable front panel enables cleaning of the
diffuser and ductwork
MATERIAL AND FINISHING
PART
MATERIAL
Casing
Galvanised steel
Front panel
Perforated steel
Deflector panels
Steel
Coupling sleeve
Galvanised steel
Gasket
Rubber compound
Finishing
Painted White RAL 9010
NOTE
Special colours available
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
1
qv
DTR-100-300 (R4)
DTR-125-300(R4)
DTR-160-450(R4)
DTR-200-450(R4)
DTR-200-600(R4)
DTR-315-600(R4)
DTR-315-600(R4)
Pa
192
288
384
480
576
768
960
1152
1344
1536
1920
2400
2880
3360
4800
l/s
20
30
40
50
60
80
100
120
140
160
200
250
300
350
400
m 3/h
72
108
144
180
216
288
360
432
504
576
720
900
1080
1260
1440
LpA
20
31
41
51
DPst
3
7
12
18
DPtot
7
15
27
43
Ld
-
-
-
-
Lmin
-
-
-
-
L0.2
0,8
1,2
1,6
2,0
LpA
21
26
32
38
50
DPst
3
5
8
11
19
DPtot
6
11
18
25
45
Ld
-
-
-
-
-
Lmin
-
-
-
-
0,5
L0.2
1,2
1,6
2,0
2,2
2,4
LpA
20
25
34
43
DPst
2
3
5
8
DPtot
6
8
15
23
Ld
-
-
-
-
Lmin
-
0,5
0,5
0,8
L0.2
1,2
1,6
2,0
2,4
LpA
22
27
32
38
43
DPst
2
4
5
7
10
DPtot
6
10
14
19
25
Ld
-
-
-
-
-
Lmin
0,5
0,6
0,9
1,2
1,5
L0.2
1,8
2,2
2,6
3,0
3,2
LpA
23
29
35
41
47
DPst
2
4
5
7
9
DPtot
6
10
14
19
25
Ld
-
-
-
-
-
Lmin
0,5
0,6
1,0
1,3
1,6
L0.2
1,8
2,2
2,6
3,0
3,4
LpA
18
23
28
32
41
DPst
2
3
4
6
9
DPtot
5
7
9
12
19
Ld
-
-
-
-
-
Lmin
0,5
0,5
0,8
1,0
1,5
L0.2
1,8
2,2
2,4
2,6
3,2
LpA
20
26
34
40
46
DPst
3
5
8
11
15
DPtot
6
9
14
20
27
Ld
2,2
2,6
3,2
3,6
4,0
Lmin
-
0,5
0,5
0,5
0,8
L0.2
4,8
5,2
6,0
6,4
6,8
LpA values presented with room attenuation 4 dB (red 10m 2 sab). When using room attenuation 8 dB (red 25m 2 - sab):
LpA - 4dB.
Pa
LpA
DPst DPtot Total pressure drop, Pa
Ld
Distance from the supply unit, at which air jet detaches from ceiling, m
Lmin
Minimum distance between central lines of two supply units, m (V3 = 0,25m/s at 1.8m height)
L0.2
Isotermal throw length, m when residual velocity of supply air jet 0,2 m/s
Room temperature
(Tr) = 24 °C
Supply air temperature
(Ta) = 16 °C
Room height
= 2,8 m
Supply air cooling capacity, W
A-weighted sound pressure level, reduced by total equivalent absorption surface of 10m 2, dB(A) red 10m 2 - sab
Static pressure drop, Pa
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
2
Halton reserves the right to alter products without notice
QUICK SELECTION
Halton reserves the right to alter products without notice
Function
•Air is supplied horizontally into the space through
temperature difference between supply and room air
the front panel of the diffuser
as follows:
•The supply air can be deflected in different
-8°C for 3 and 4 direction air supply
directions (1,2,3,4) with a recommended maximum air
-6°C for 1 and 2 direction air supply
DTR can also be used as an exhaust unit.
ACCESSORIES
ACCESSORY
CODE
DESCRIPTION
Balancing plenum
TRI
For balancing & equalising the airflow and attenuating the duct noise
Deflector panels
DP
Set of deflector panels for selection of flow pattern to 1,2 or 3 directions
W
W1
H
ØD
100-300
300
259
77
99
100-600
595
259
77
99
125-300
300
259
77
124
125-600
595
259
77
124
160-450
452
411
97
159
160-600
595
411
97
159
200-450
452
411
97
199
200-600
595
554
97
199
250-600
595
554
97
249
315-600
595
554
97
314
NS = Connection size - Diffuser size
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
3
7
NS
H
DIMENSIONS
Halton reserves the right to alter products without notice
Installation
Installation with plenum TRI
The diffuser is connected either directly to the duct
by screwing or by riveting or alternatively to the TRI
balancing plenum.
Direct the flow pattern in the desired directions by
ØD1
installing a deflector panel on the perforated front
ØD
H1
panel.
A minimum safety distance upstream of the diffuser
of 3xD is recommended.
7
W2
In an exhaust application neither a deflector panel or a
deflector plate is used.
DTR (ØD)
ØD1
TRI
W2
H1
The collar of TRI plenum can be installed either
100-300
100
TRI-100-100
270
293-343
internally in the plenum or externally on the bottom
125-300
100
TRI-100-125
270
293-343
of the plenum. The height of the unit is presented in
160-450
125
TRI-125-160
425
343-393
the table below for the external installation. When the
200-450
160
TRI-160-200
425
383-433
200-600
160
TRI-160-200
565
383-433
250-600
200
TRI-200-250
565
433-483
315-600
250
TRI-250-315
565
497-547
collar sleeve is installed internally, the total height H1
is reduced by 60 mm.
The technical performance for the combination of
supply air diffuser and TRI plenum is presented
separately for the two different installations. See HIT
Design software.
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
4
Halton reserves the right to alter products without notice
Adjustment
Servicing
It is not possible to adjust airflow in the DTR itself.
Detach the front panel by gently pulling it down and
In order to enable airflow adjustment and
letting it balance on the hinges.
measurement of airflow rate it is recommended that
Clean the parts by wiping them with a damp cloth.
the diffuser is connected to the TRI balancing plenum.
Reattach the front panel by swinging it up and pushing
The supply flow rate is determined by using the MSM
it until the springs lock.
measurement and adjustment module.
Open the front panel and pass the tubes and control
Option with balancing plenum
spindle through the diffuser front plate.
Remove the measurement and adjustment module
Replace the front plate.
by gently pulling the shaft; (not the control spindle or
Measure the differential pressure using a manometer.
measurement tubes!).
The flow rate is calculated using the formula below.
Wipe the parts with a damp cloth, instead of
immersing in water.
Reassemble the measurement and adjustment
qv = k *
∆pm
module by pushing the shaft until the module meets
the stopper.
Push the front panel back into place so that the
Adjust the airflow rate by rotating the control spindle
springs lock.
until the desired setting is achieved.
Lock the damper position with a screw.
Replace the tubes and spindle in the plenum and
replace the diffuser front panel.
K factor for installations with different safety distances
(D= duct diameter)
TRI/S
>8XD
min 3XD
100
6.0
7.5
125
9.9
12.6
160
16.9
21.9
200
28.3
31.0
250
47.9
51.5
315
78.6
-
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
5
DTR-100-300, DTR-125-300,
DTR-200-600, DTR-250-600,
DTR-160-450, DTR-200-450 4-way pattern
DTR-315-600, 4-way pattern
DTR-100-300, DTR-125-300,
DTR-200-600, DTR-250-600,
DTR-160-450, DTR-200-450 3-way pattern
DTR-315-600, 3-way pattern
Selection example :
Requirements :
qv = 250 l/s
LpA < 35 dB(A) L0,2 < 6,0 m
4-way pattern
Selection :DTR-315-600
LpA < 34 dB(A)
L0.2 < 5,5 m
DPtot = 14 Pa
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
6
Note:
Recommended minimum supply temperature, 8°C below
room for 4 and 3-way patterns.
Halton reserves the right to alter products without notice
Pressure drop, throw pattern and sound data, supply
DTR-100-300, DTR-125-300,
DTR-200-600, DTR-250-600,
DTR-160-450, DTR-200-450 2-way pattern
DTR-315-600, 2-way pattern
DTR-100-300, DTR-125-300,
DTR-200-600, DTR-250-600,
DTR-160-450, DTR-200-450 1-way pattern
DTR-315-600, 1-way pattern
Note:
Recommended minimum supply temperature, 6°C below
room, for 2 and 1-way patterns.
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
7
Halton reserves the right to alter products without notice
Pressure drop, throw pattern and sound data, supply
DTR
qv
(l/s)
(m 3/h)
DPst
(Pa)
DPtot
(Pa)
F (Hz)
4 way pattern
63
125
250
500
1000
2000
4000
[dB(A)]
NR
NC
DTR-100-300(R4)
25
29
34
39
90
104
122
140
4
6
8
11
10
15
20
26
39
39
39
40
19
22
25
27
26
29
32
34
31
36
40
44
18
27
35
41
3
9
18
27
3
3
4
7
25
30
35
40
23
28
32
37
22
26
31
36
DTR-125-300(R4)
37
47
56
63
133
169
202
227
4
7
9
12
10
15
22
28
42
44
45
46
26
28
29
30
24
28
31
33
31
36
39
42
16
27
35
42
3
11
20
28
3
3
5
9
25
30
35
40
23
28
31
38
22
26
30
37
DTR-160-450(R4)
60
71
82
93
216
256
295
335
3
4
5
7
8
11
15
20
36
38
39
41
21
24
26
29
27
30
32
35
31
36
40
43
19
28
35
42
3
9
17
25
3
3
4
6
25
30
35
40
23
28
32
38
21
26
31
36
DTR-200-450(R4)
92
111
130
150
331
400
468
540
3
5
6
8
8
12
17
22
44
45
46
47
26
29
31
32
26
30
32
35
31
36
40
44
18
27
35
42
3
10
18
25
3
3
4
7
25
30
35
40
23
28
32
38
21
27
31
37
DTR-200-600(R4)
87
103
119
136
313
371
428
490
3
4
5
7
7
10
14
18
42
43
44
45
26
27
28
29
27
30
33
35
31
36
40
44
18
27
35
42
3
8
18
26
3
3
3
6
25
30
35
40
23
28
32
38
21
27
31
36
DTR-250-600(R4)
129
150
173
196
464
540
623
706
4
5
7
9
8
11
14
18
39
40
41
42
24
26
28
29
27
30
32
35
31
36
40
44
19
27
34
41
3
9
17
25
3
3
3
6
25
30
35
40
23
28
32
37
21
26
31
35
DTR-315-600(R4)
191
224
259
299
688
806
932
1076
5
6
8
11
8
11
15
20
44
46
48
49
26
28
30
31
27
30
32
35
31
36
40
45
19
27
33
40
3
11
18
25
3
3
4
7
25
30
35
40
23
28
32
37
21
26
31
36
DTR
qv
(l/s)
(m 3/h)
DPst
(Pa)
DPtot
(Pa)
F (Hz)
3 way pattern
LpA
NR
NC
63
125
250
500
1000
2000
4000
[dB(A)]
DTR-100-300(R3)
25
29
34
39
90
104
122
140
5
7
9
12
11
15
21
27
39
40
41
41
20
23
25
27
26
29
31
34
31
36
40
43
19
27
35
41
3
9
18
27
3
3
3
6
25
30
35
40
23
28
32
37
21
26
30
36
DTR-125-300(R3)
37
45
54
62
133
162
194
223
5
7
10
13
10
15
22
29
42
43
44
44
21
25
28
31
24
28
31
34
31
36
40
43
17
26
35
42
3
10
20
28
3
3
4
8
25
30
35
40
23
28
32
38
22
26
30
37
DTR-160-450(R3)
60
71
82
93
216
256
295
335
3
5
6
8
9
12
16
21
37
39
42
44
21
24
27
30
27
30
33
36
31
36
40
43
20
28
35
42
3
9
18
26
3
3
3
6
25
30
35
40
23
28
32
38
21
26
30
36
DTR-200-450(R3)
90
107
125
143
324
385
450
515
4
5
7
9
9
12
16
22
42
43
44
45
26
28
30
32
27
30
33
35
31
36
40
44
19
27
35
41
3
9
18
26
3
3
3
6
25
30
35
40
23
28
32
37
21
26
31
36
DTR-200-600(R3)
87
102
117
134
313
367
421
482
3
4
6
8
8
11
14
19
41
42
43
44
23
25
28
30
28
30
33
36
31
36
40
44
19
27
35
41
3
10
18
26
3
3
3
6
25
30
35
40
23
28
32
37
21
26
31
36
DTR-250-600(R3)
124
146
169
192
446
526
608
691
4
6
8
10
8
11
15
19
40
41
42
43
25
27
29
31
27
30
32
35
31
36
40
44
19
27
34
41
3
10
18
25
3
3
4
7
25
30
35
40
23
28
32
37
21
26
31
36
DTR-315-600(R3)
179
644
5
211
760
7
244
878
10
280
1008
13
LpA values presented with room attenuation 4 dB
NR/NC noise criteria
LpA
9
43
24
12
44
27
16
45
29
21
46
32
(red 10m 2 - sab). When
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
8
28
31
33
36
using
31
20
3
3
25
36
27
9
3
30
40
34
18
3
35
44
41
25
7
40
room attenuation 8 dB (red 25m 2 - sab):
23
21
28
26
32
31
37
36
LpA - 4dB.
Halton reserves the right to alter products without notice
SOUND LEVEL DATA, SUPPLY
DTR
qv
(l/s)
(m 3/h)
DPst
(Pa)
DPtot
(Pa)
F (Hz)
2 way pattern
63
125
250
500
1000
2000
4000
[dB(A)]
NR
NC
DTR-100-300(R2)
27
31
37
42
97
112
133
151
5
8
10
13
12
17
23
30
38
40
42
43
20
23
26
28
26
29
31
34
31
35
39
42
22
29
36
42
4
13
21
28
3
3
5
10
25
30
35
40
23
27
32
38
21
25
30
37
DTR-125-300(R2)
38
45
53
61
137
162
191
220
5
7
10
13
11
15
21
28
42
43
44
44
25
26
28
29
26
29
32
34
31
36
39
42
19
28
35
42
3
11
20
27
3
3
4
7
25
30
35
40
23
27
31
38
21
26
30
37
DTR-160-450(R2)
61
72
83
95
220
259
299
342
4
5
7
9
9
13
17
22
43
44
45
46
25
27
29
31
28
31
33
36
30
35
39
43
20
28
35
41
3
9
18
26
3
3
3
6
25
30
35
40
22
27
31
37
20
25
30
36
DTR-200-450(R2)
89
104
120
137
320
374
432
493
4
6
7
10
9
12
16
21
36
37
38
38
22
25
28
30
29
31
33
36
31
35
40
44
21
28
35
41
3
9
17
25
3
3
3
5
25
30
35
40
22
27
32
37
21
26
30
36
DTR-200-600(R2)
87
102
118
135
313
367
425
486
4
5
7
9
8
11
15
20
41
42
43
44
24
27
29
32
28
31
33
36
31
36
40
44
20
27
35
41
3
10
19
27
3
3
3
7
25
30
35
40
23
28
32
37
21
26
31
36
DTR-250-600(R2)
109
132
156
183
392
475
562
659
4
6
8
11
7
10
14
19
41
43
44
45
26
28
30
32
27
30
33
35
31
36
40
44
20
28
34
41
11
16
20
24
3
3
3
5
25
30
35
40
22
27
32
37
21
26
31
36
DTR-315-600(R2)
159
188
219
252
572
677
788
907
5
8
10
14
8
11
15
20
45
46
47
48
25
28
30
32
28
31
33
36
31
36
40
44
19
27
34
41
3
8
17
25
3
3
3
7
25
30
35
40
22
27
32
37
21
26
31
35
DTR
qv
(l/s)
(m 3/h)
DPst
(Pa)
DPtot
(Pa)
F (Hz)
1 way pattern
LpA
NR
NC
63
125
250
500
1000
2000
4000
[dB(A)]
DTR-100-300(R1)
24
29
34
39
86
104
122
140
9
12
17
23
15
21
29
38
43
44
45
45
22
25
29
32
25
28
32
35
30
34
38
42
23
30
36
42
6
15
23
31
3
3
9
15
25
30
35
40
22
26
32
38
20
25
31
37
DTR-125-300(R1)
30
36
43
50
108
130
155
180
9
14
19
26
13
19
27
36
39
40
41
41
25
27
29
31
27
30
33
36
31
35
39
42
21
29
36
42
4
14
23
30
3
3
7
13
25
30
35
40
23
27
32
38
21
25
30
37
DTR-160-450(R1)
52
62
72
83
187
223
259
299
7
9
13
17
11
15
20
27
41
42
43
44
24
27
30
33
27
30
33
36
31
35
39
43
20
29
36
42
3
12
20
28
3
3
7
13
25
30
35
40
23
27
32
38
21
26
30
37
DTR-200-450(R1)
70
84
98
113
252
302
353
407
7
11
14
19
10
15
20
27
39
40
41
42
22
26
30
33
27
30
33
36
31
35
39
42
21
29
36
42
3
12
20
28
3
3
6
11
25
30
35
40
23
27
32
38
21
26
31
37
DTR-200-600(R1)
74
87
100
114
266
313
360
410
6
9
12
15
10
13
18
23
39
40
41
42
24
28
31
33
28
32
35
37
30
35
39
43
22
29
36
41
3
12
20
28
3
3
4
7
25
30
35
40
22
27
32
37
20
25
30
36
DTR-250-600(R1)
92
109
127
146
331
392
457
526
7
10
14
19
10
13
18
24
39
40
41
42
22
26
29
32
26
30
33
35
31
35
40
44
21
28
35
41
3
10
19
27
3
3
4
9
25
30
35
40
23
27
32
37
21
26
30
36
DTR-315-600(R1)
108
389
9
128
461
12
149
536
16
171
616
22
LpA values presented with room attenuation 4 dB
NR/NC noise criteria
LpA
10
41
24
14
42
26
18
43
29
24
44
31
(red 10m 2 - sab). When
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
9
26
29
32
35
using
31
20
3
3
25
36
28
9
3
30
40
35
18
3
35
44
41
26
6
40
room attenuation 8 dB (red 25m 2 - sab):
23
21
28
26
32
31
37
36
LpA - 4dB.
Halton reserves the right to alter products without notice
SOUND LEVEL DATA, SUPPLY
Halton reserves the right to alter products without notice
Pressure drop and sound data, exhaust
DTR-100-300, DTR-125-300,
DTR-200-600, DTR-250-600,
DTR-160-450, DTR-200-450
DTR-315-600
SOUND LEVEL DATA, EXHAUST
DTR
qv
(l/s)
(m 3/h)
DPst
(Pa)
DPtot
(Pa)
F (Hz)
Exhaust
63
125
250
500
1000
2000
4000
[dB(A)]
DTR-100-300(E)
43
51
59
70
155
184
212
252
38
53
72
100
20
28
38
52
41
42
43
44
34
38
42
45
32
37
42
47
29
34
39
44
20
25
30
35
8
15
22
28
3
7
14
21
DTR-125-300(E)
65
77
91
108
234
277
328
389
36
51
71
100
19
27
38
53
32
33
35
36
33
37
40
43
30
36
41
46
30
35
39
44
20
26
31
37
10
17
24
31
DTR-160-450(E)
124
146
170
199
446
526
612
716
45
63
85
116
22
31
42
57
42
43
44
45
35
39
42
46
33
39
44
49
27
33
38
43
20
25
29
34
DTR-200-450(E)
178
217
259
309
641
781
932
1112
39
57
81
116
19
28
41
58
43
44
45
46
36
40
43
47
31
37
42
47
29
34
38
43
DTR-200-600(E)
209
247
290
340
752
889
1044
1224
51
71
98
135
24
34
47
64
39
40
41
43
34
38
41
45
31
37
42
48
DTR-250-600(E)
306
363
427
501
1102
1307
1537
1804
48
68
94
130
25
35
49
67
39
41
43
44
34
38
42
45
29
35
41
46
DTR-315-600(E)
395
1422
36
477
1717
52
572
2059
75
681
2452
107
LpA values presented with room attenuation 4 dB
NR/NC noise criteria
LpA
20
41
33
30
43
37
43
45
41
61
47
45
(red 10m 2 - sab). When
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
10
31
36
40
45
using
NR
NC
25
30
35
40
20
26
31
37
19
25
30
36
3
8
16
24
25
30
35
40
22
27
31
36
20
25
30
35
10
17
23
29
3
11
18
25
25
30
35
40
19
25
30
35
17
23
28
34
20
26
32
37
10
17
24
31
3
8
16
23
25
30
35
40
21
26
30
35
19
24
29
34
28
33
37
42
23
28
33
38
12
19
26
33
4
12
19
27
25
30
35
40
20
25
29
34
18
23
28
33
30
34
38
43
21
27
33
38
12
19
26
33
3
10
18
26
25
30
35
40
21
26
30
35
20
25
29
34
29
22
9
3
25
34
28
17
5
30
38
34
24
14
35
43
39
32
22
40
room attenuation 8 dB (red 25m 2 - sab):
21
19
26
24
30
29
35
34
LpA - 4dB.
Product Code
The diffuser shall be made of painted steel with a
DTR-D-A
white (RAL 9010) colour.
The flow pattern of the diffuser shall be adjustable in
D = Diameter of duct connection
up to three directions using deflector panels.
Option 1; no balancing plenum
A = Diffuser size
The diffuser shall have a galvanised steel casing with
D=100: 300, 600
a spigot with integral gasket for connection to circular
D=125: 300, 600
duct.
D=160: 450, 600
The diffuser shall have a detachable perforated front
D=200: 450, 600
panel that provides access to the duct.
D=250: 600
D=315: 600
100, 125, 160, 200, 250, 315
Option 2; option with balancing plenum
The diffuser shall be connected to a balancing plenum
Specifics and accessories
equipped with a measurement and adjustment
module.
CO = Colour
The diffuser shall have a detachable perforated front
W
White
panel to provide access to the measurement and
X
Special colour
adjustment module in the plenum.
The balancing plenum shall have a spigot with integral
Code example
gasket for air-tight duct connection.
The balancing plenum shall comprise sound
DTR-100-300, CO=W
attenuation material made of polyester fiber with a
washable surface.
Sub products
DTR - Perforated
Ceiling til
Diffuser
Perforeret diffusor
loftsmontage
11
TRI
Plenum (Diffusers)
DP
Deflection panel
Halton reserves the right to alter products without notice
Suggested Specifications