Halton DTR
Transcription
Halton DTR
Halton reserves the right to alter products without notice Halton DTR Perforated Ceiling Diffuser © Halton •Horizontal air supply in four directions, also suitable Accessories for exhaust •Deflector for the direction of flow pattern (up to •Installation flush to the ceiling, low unit height three directions) •Available in sizes 300,450 and 600 •Balancing plenum with measurement and •Size 600 adapted for installation in modular adjustment functions 600x600 mm suspended ceiling •Openable front panel enables cleaning of the diffuser and ductwork MATERIAL AND FINISHING PART MATERIAL Casing Galvanised steel Front panel Perforated steel Deflector panels Steel Coupling sleeve Galvanised steel Gasket Rubber compound Finishing Painted White RAL 9010 NOTE Special colours available DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 1 qv DTR-100-300 (R4) DTR-125-300(R4) DTR-160-450(R4) DTR-200-450(R4) DTR-200-600(R4) DTR-315-600(R4) DTR-315-600(R4) Pa 192 288 384 480 576 768 960 1152 1344 1536 1920 2400 2880 3360 4800 l/s 20 30 40 50 60 80 100 120 140 160 200 250 300 350 400 m 3/h 72 108 144 180 216 288 360 432 504 576 720 900 1080 1260 1440 LpA 20 31 41 51 DPst 3 7 12 18 DPtot 7 15 27 43 Ld - - - - Lmin - - - - L0.2 0,8 1,2 1,6 2,0 LpA 21 26 32 38 50 DPst 3 5 8 11 19 DPtot 6 11 18 25 45 Ld - - - - - Lmin - - - - 0,5 L0.2 1,2 1,6 2,0 2,2 2,4 LpA 20 25 34 43 DPst 2 3 5 8 DPtot 6 8 15 23 Ld - - - - Lmin - 0,5 0,5 0,8 L0.2 1,2 1,6 2,0 2,4 LpA 22 27 32 38 43 DPst 2 4 5 7 10 DPtot 6 10 14 19 25 Ld - - - - - Lmin 0,5 0,6 0,9 1,2 1,5 L0.2 1,8 2,2 2,6 3,0 3,2 LpA 23 29 35 41 47 DPst 2 4 5 7 9 DPtot 6 10 14 19 25 Ld - - - - - Lmin 0,5 0,6 1,0 1,3 1,6 L0.2 1,8 2,2 2,6 3,0 3,4 LpA 18 23 28 32 41 DPst 2 3 4 6 9 DPtot 5 7 9 12 19 Ld - - - - - Lmin 0,5 0,5 0,8 1,0 1,5 L0.2 1,8 2,2 2,4 2,6 3,2 LpA 20 26 34 40 46 DPst 3 5 8 11 15 DPtot 6 9 14 20 27 Ld 2,2 2,6 3,2 3,6 4,0 Lmin - 0,5 0,5 0,5 0,8 L0.2 4,8 5,2 6,0 6,4 6,8 LpA values presented with room attenuation 4 dB (red 10m 2 sab). When using room attenuation 8 dB (red 25m 2 - sab): LpA - 4dB. Pa LpA DPst DPtot Total pressure drop, Pa Ld Distance from the supply unit, at which air jet detaches from ceiling, m Lmin Minimum distance between central lines of two supply units, m (V3 = 0,25m/s at 1.8m height) L0.2 Isotermal throw length, m when residual velocity of supply air jet 0,2 m/s Room temperature (Tr) = 24 °C Supply air temperature (Ta) = 16 °C Room height = 2,8 m Supply air cooling capacity, W A-weighted sound pressure level, reduced by total equivalent absorption surface of 10m 2, dB(A) red 10m 2 - sab Static pressure drop, Pa DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 2 Halton reserves the right to alter products without notice QUICK SELECTION Halton reserves the right to alter products without notice Function •Air is supplied horizontally into the space through temperature difference between supply and room air the front panel of the diffuser as follows: •The supply air can be deflected in different -8°C for 3 and 4 direction air supply directions (1,2,3,4) with a recommended maximum air -6°C for 1 and 2 direction air supply DTR can also be used as an exhaust unit. ACCESSORIES ACCESSORY CODE DESCRIPTION Balancing plenum TRI For balancing & equalising the airflow and attenuating the duct noise Deflector panels DP Set of deflector panels for selection of flow pattern to 1,2 or 3 directions W W1 H ØD 100-300 300 259 77 99 100-600 595 259 77 99 125-300 300 259 77 124 125-600 595 259 77 124 160-450 452 411 97 159 160-600 595 411 97 159 200-450 452 411 97 199 200-600 595 554 97 199 250-600 595 554 97 249 315-600 595 554 97 314 NS = Connection size - Diffuser size DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 3 7 NS H DIMENSIONS Halton reserves the right to alter products without notice Installation Installation with plenum TRI The diffuser is connected either directly to the duct by screwing or by riveting or alternatively to the TRI balancing plenum. Direct the flow pattern in the desired directions by ØD1 installing a deflector panel on the perforated front ØD H1 panel. A minimum safety distance upstream of the diffuser of 3xD is recommended. 7 W2 In an exhaust application neither a deflector panel or a deflector plate is used. DTR (ØD) ØD1 TRI W2 H1 The collar of TRI plenum can be installed either 100-300 100 TRI-100-100 270 293-343 internally in the plenum or externally on the bottom 125-300 100 TRI-100-125 270 293-343 of the plenum. The height of the unit is presented in 160-450 125 TRI-125-160 425 343-393 the table below for the external installation. When the 200-450 160 TRI-160-200 425 383-433 200-600 160 TRI-160-200 565 383-433 250-600 200 TRI-200-250 565 433-483 315-600 250 TRI-250-315 565 497-547 collar sleeve is installed internally, the total height H1 is reduced by 60 mm. The technical performance for the combination of supply air diffuser and TRI plenum is presented separately for the two different installations. See HIT Design software. DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 4 Halton reserves the right to alter products without notice Adjustment Servicing It is not possible to adjust airflow in the DTR itself. Detach the front panel by gently pulling it down and In order to enable airflow adjustment and letting it balance on the hinges. measurement of airflow rate it is recommended that Clean the parts by wiping them with a damp cloth. the diffuser is connected to the TRI balancing plenum. Reattach the front panel by swinging it up and pushing The supply flow rate is determined by using the MSM it until the springs lock. measurement and adjustment module. Open the front panel and pass the tubes and control Option with balancing plenum spindle through the diffuser front plate. Remove the measurement and adjustment module Replace the front plate. by gently pulling the shaft; (not the control spindle or Measure the differential pressure using a manometer. measurement tubes!). The flow rate is calculated using the formula below. Wipe the parts with a damp cloth, instead of immersing in water. Reassemble the measurement and adjustment qv = k * ∆pm module by pushing the shaft until the module meets the stopper. Push the front panel back into place so that the Adjust the airflow rate by rotating the control spindle springs lock. until the desired setting is achieved. Lock the damper position with a screw. Replace the tubes and spindle in the plenum and replace the diffuser front panel. K factor for installations with different safety distances (D= duct diameter) TRI/S >8XD min 3XD 100 6.0 7.5 125 9.9 12.6 160 16.9 21.9 200 28.3 31.0 250 47.9 51.5 315 78.6 - DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 5 DTR-100-300, DTR-125-300, DTR-200-600, DTR-250-600, DTR-160-450, DTR-200-450 4-way pattern DTR-315-600, 4-way pattern DTR-100-300, DTR-125-300, DTR-200-600, DTR-250-600, DTR-160-450, DTR-200-450 3-way pattern DTR-315-600, 3-way pattern Selection example : Requirements : qv = 250 l/s LpA < 35 dB(A) L0,2 < 6,0 m 4-way pattern Selection :DTR-315-600 LpA < 34 dB(A) L0.2 < 5,5 m DPtot = 14 Pa DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 6 Note: Recommended minimum supply temperature, 8°C below room for 4 and 3-way patterns. Halton reserves the right to alter products without notice Pressure drop, throw pattern and sound data, supply DTR-100-300, DTR-125-300, DTR-200-600, DTR-250-600, DTR-160-450, DTR-200-450 2-way pattern DTR-315-600, 2-way pattern DTR-100-300, DTR-125-300, DTR-200-600, DTR-250-600, DTR-160-450, DTR-200-450 1-way pattern DTR-315-600, 1-way pattern Note: Recommended minimum supply temperature, 6°C below room, for 2 and 1-way patterns. DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 7 Halton reserves the right to alter products without notice Pressure drop, throw pattern and sound data, supply DTR qv (l/s) (m 3/h) DPst (Pa) DPtot (Pa) F (Hz) 4 way pattern 63 125 250 500 1000 2000 4000 [dB(A)] NR NC DTR-100-300(R4) 25 29 34 39 90 104 122 140 4 6 8 11 10 15 20 26 39 39 39 40 19 22 25 27 26 29 32 34 31 36 40 44 18 27 35 41 3 9 18 27 3 3 4 7 25 30 35 40 23 28 32 37 22 26 31 36 DTR-125-300(R4) 37 47 56 63 133 169 202 227 4 7 9 12 10 15 22 28 42 44 45 46 26 28 29 30 24 28 31 33 31 36 39 42 16 27 35 42 3 11 20 28 3 3 5 9 25 30 35 40 23 28 31 38 22 26 30 37 DTR-160-450(R4) 60 71 82 93 216 256 295 335 3 4 5 7 8 11 15 20 36 38 39 41 21 24 26 29 27 30 32 35 31 36 40 43 19 28 35 42 3 9 17 25 3 3 4 6 25 30 35 40 23 28 32 38 21 26 31 36 DTR-200-450(R4) 92 111 130 150 331 400 468 540 3 5 6 8 8 12 17 22 44 45 46 47 26 29 31 32 26 30 32 35 31 36 40 44 18 27 35 42 3 10 18 25 3 3 4 7 25 30 35 40 23 28 32 38 21 27 31 37 DTR-200-600(R4) 87 103 119 136 313 371 428 490 3 4 5 7 7 10 14 18 42 43 44 45 26 27 28 29 27 30 33 35 31 36 40 44 18 27 35 42 3 8 18 26 3 3 3 6 25 30 35 40 23 28 32 38 21 27 31 36 DTR-250-600(R4) 129 150 173 196 464 540 623 706 4 5 7 9 8 11 14 18 39 40 41 42 24 26 28 29 27 30 32 35 31 36 40 44 19 27 34 41 3 9 17 25 3 3 3 6 25 30 35 40 23 28 32 37 21 26 31 35 DTR-315-600(R4) 191 224 259 299 688 806 932 1076 5 6 8 11 8 11 15 20 44 46 48 49 26 28 30 31 27 30 32 35 31 36 40 45 19 27 33 40 3 11 18 25 3 3 4 7 25 30 35 40 23 28 32 37 21 26 31 36 DTR qv (l/s) (m 3/h) DPst (Pa) DPtot (Pa) F (Hz) 3 way pattern LpA NR NC 63 125 250 500 1000 2000 4000 [dB(A)] DTR-100-300(R3) 25 29 34 39 90 104 122 140 5 7 9 12 11 15 21 27 39 40 41 41 20 23 25 27 26 29 31 34 31 36 40 43 19 27 35 41 3 9 18 27 3 3 3 6 25 30 35 40 23 28 32 37 21 26 30 36 DTR-125-300(R3) 37 45 54 62 133 162 194 223 5 7 10 13 10 15 22 29 42 43 44 44 21 25 28 31 24 28 31 34 31 36 40 43 17 26 35 42 3 10 20 28 3 3 4 8 25 30 35 40 23 28 32 38 22 26 30 37 DTR-160-450(R3) 60 71 82 93 216 256 295 335 3 5 6 8 9 12 16 21 37 39 42 44 21 24 27 30 27 30 33 36 31 36 40 43 20 28 35 42 3 9 18 26 3 3 3 6 25 30 35 40 23 28 32 38 21 26 30 36 DTR-200-450(R3) 90 107 125 143 324 385 450 515 4 5 7 9 9 12 16 22 42 43 44 45 26 28 30 32 27 30 33 35 31 36 40 44 19 27 35 41 3 9 18 26 3 3 3 6 25 30 35 40 23 28 32 37 21 26 31 36 DTR-200-600(R3) 87 102 117 134 313 367 421 482 3 4 6 8 8 11 14 19 41 42 43 44 23 25 28 30 28 30 33 36 31 36 40 44 19 27 35 41 3 10 18 26 3 3 3 6 25 30 35 40 23 28 32 37 21 26 31 36 DTR-250-600(R3) 124 146 169 192 446 526 608 691 4 6 8 10 8 11 15 19 40 41 42 43 25 27 29 31 27 30 32 35 31 36 40 44 19 27 34 41 3 10 18 25 3 3 4 7 25 30 35 40 23 28 32 37 21 26 31 36 DTR-315-600(R3) 179 644 5 211 760 7 244 878 10 280 1008 13 LpA values presented with room attenuation 4 dB NR/NC noise criteria LpA 9 43 24 12 44 27 16 45 29 21 46 32 (red 10m 2 - sab). When DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 8 28 31 33 36 using 31 20 3 3 25 36 27 9 3 30 40 34 18 3 35 44 41 25 7 40 room attenuation 8 dB (red 25m 2 - sab): 23 21 28 26 32 31 37 36 LpA - 4dB. Halton reserves the right to alter products without notice SOUND LEVEL DATA, SUPPLY DTR qv (l/s) (m 3/h) DPst (Pa) DPtot (Pa) F (Hz) 2 way pattern 63 125 250 500 1000 2000 4000 [dB(A)] NR NC DTR-100-300(R2) 27 31 37 42 97 112 133 151 5 8 10 13 12 17 23 30 38 40 42 43 20 23 26 28 26 29 31 34 31 35 39 42 22 29 36 42 4 13 21 28 3 3 5 10 25 30 35 40 23 27 32 38 21 25 30 37 DTR-125-300(R2) 38 45 53 61 137 162 191 220 5 7 10 13 11 15 21 28 42 43 44 44 25 26 28 29 26 29 32 34 31 36 39 42 19 28 35 42 3 11 20 27 3 3 4 7 25 30 35 40 23 27 31 38 21 26 30 37 DTR-160-450(R2) 61 72 83 95 220 259 299 342 4 5 7 9 9 13 17 22 43 44 45 46 25 27 29 31 28 31 33 36 30 35 39 43 20 28 35 41 3 9 18 26 3 3 3 6 25 30 35 40 22 27 31 37 20 25 30 36 DTR-200-450(R2) 89 104 120 137 320 374 432 493 4 6 7 10 9 12 16 21 36 37 38 38 22 25 28 30 29 31 33 36 31 35 40 44 21 28 35 41 3 9 17 25 3 3 3 5 25 30 35 40 22 27 32 37 21 26 30 36 DTR-200-600(R2) 87 102 118 135 313 367 425 486 4 5 7 9 8 11 15 20 41 42 43 44 24 27 29 32 28 31 33 36 31 36 40 44 20 27 35 41 3 10 19 27 3 3 3 7 25 30 35 40 23 28 32 37 21 26 31 36 DTR-250-600(R2) 109 132 156 183 392 475 562 659 4 6 8 11 7 10 14 19 41 43 44 45 26 28 30 32 27 30 33 35 31 36 40 44 20 28 34 41 11 16 20 24 3 3 3 5 25 30 35 40 22 27 32 37 21 26 31 36 DTR-315-600(R2) 159 188 219 252 572 677 788 907 5 8 10 14 8 11 15 20 45 46 47 48 25 28 30 32 28 31 33 36 31 36 40 44 19 27 34 41 3 8 17 25 3 3 3 7 25 30 35 40 22 27 32 37 21 26 31 35 DTR qv (l/s) (m 3/h) DPst (Pa) DPtot (Pa) F (Hz) 1 way pattern LpA NR NC 63 125 250 500 1000 2000 4000 [dB(A)] DTR-100-300(R1) 24 29 34 39 86 104 122 140 9 12 17 23 15 21 29 38 43 44 45 45 22 25 29 32 25 28 32 35 30 34 38 42 23 30 36 42 6 15 23 31 3 3 9 15 25 30 35 40 22 26 32 38 20 25 31 37 DTR-125-300(R1) 30 36 43 50 108 130 155 180 9 14 19 26 13 19 27 36 39 40 41 41 25 27 29 31 27 30 33 36 31 35 39 42 21 29 36 42 4 14 23 30 3 3 7 13 25 30 35 40 23 27 32 38 21 25 30 37 DTR-160-450(R1) 52 62 72 83 187 223 259 299 7 9 13 17 11 15 20 27 41 42 43 44 24 27 30 33 27 30 33 36 31 35 39 43 20 29 36 42 3 12 20 28 3 3 7 13 25 30 35 40 23 27 32 38 21 26 30 37 DTR-200-450(R1) 70 84 98 113 252 302 353 407 7 11 14 19 10 15 20 27 39 40 41 42 22 26 30 33 27 30 33 36 31 35 39 42 21 29 36 42 3 12 20 28 3 3 6 11 25 30 35 40 23 27 32 38 21 26 31 37 DTR-200-600(R1) 74 87 100 114 266 313 360 410 6 9 12 15 10 13 18 23 39 40 41 42 24 28 31 33 28 32 35 37 30 35 39 43 22 29 36 41 3 12 20 28 3 3 4 7 25 30 35 40 22 27 32 37 20 25 30 36 DTR-250-600(R1) 92 109 127 146 331 392 457 526 7 10 14 19 10 13 18 24 39 40 41 42 22 26 29 32 26 30 33 35 31 35 40 44 21 28 35 41 3 10 19 27 3 3 4 9 25 30 35 40 23 27 32 37 21 26 30 36 DTR-315-600(R1) 108 389 9 128 461 12 149 536 16 171 616 22 LpA values presented with room attenuation 4 dB NR/NC noise criteria LpA 10 41 24 14 42 26 18 43 29 24 44 31 (red 10m 2 - sab). When DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 9 26 29 32 35 using 31 20 3 3 25 36 28 9 3 30 40 35 18 3 35 44 41 26 6 40 room attenuation 8 dB (red 25m 2 - sab): 23 21 28 26 32 31 37 36 LpA - 4dB. Halton reserves the right to alter products without notice SOUND LEVEL DATA, SUPPLY Halton reserves the right to alter products without notice Pressure drop and sound data, exhaust DTR-100-300, DTR-125-300, DTR-200-600, DTR-250-600, DTR-160-450, DTR-200-450 DTR-315-600 SOUND LEVEL DATA, EXHAUST DTR qv (l/s) (m 3/h) DPst (Pa) DPtot (Pa) F (Hz) Exhaust 63 125 250 500 1000 2000 4000 [dB(A)] DTR-100-300(E) 43 51 59 70 155 184 212 252 38 53 72 100 20 28 38 52 41 42 43 44 34 38 42 45 32 37 42 47 29 34 39 44 20 25 30 35 8 15 22 28 3 7 14 21 DTR-125-300(E) 65 77 91 108 234 277 328 389 36 51 71 100 19 27 38 53 32 33 35 36 33 37 40 43 30 36 41 46 30 35 39 44 20 26 31 37 10 17 24 31 DTR-160-450(E) 124 146 170 199 446 526 612 716 45 63 85 116 22 31 42 57 42 43 44 45 35 39 42 46 33 39 44 49 27 33 38 43 20 25 29 34 DTR-200-450(E) 178 217 259 309 641 781 932 1112 39 57 81 116 19 28 41 58 43 44 45 46 36 40 43 47 31 37 42 47 29 34 38 43 DTR-200-600(E) 209 247 290 340 752 889 1044 1224 51 71 98 135 24 34 47 64 39 40 41 43 34 38 41 45 31 37 42 48 DTR-250-600(E) 306 363 427 501 1102 1307 1537 1804 48 68 94 130 25 35 49 67 39 41 43 44 34 38 42 45 29 35 41 46 DTR-315-600(E) 395 1422 36 477 1717 52 572 2059 75 681 2452 107 LpA values presented with room attenuation 4 dB NR/NC noise criteria LpA 20 41 33 30 43 37 43 45 41 61 47 45 (red 10m 2 - sab). When DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 10 31 36 40 45 using NR NC 25 30 35 40 20 26 31 37 19 25 30 36 3 8 16 24 25 30 35 40 22 27 31 36 20 25 30 35 10 17 23 29 3 11 18 25 25 30 35 40 19 25 30 35 17 23 28 34 20 26 32 37 10 17 24 31 3 8 16 23 25 30 35 40 21 26 30 35 19 24 29 34 28 33 37 42 23 28 33 38 12 19 26 33 4 12 19 27 25 30 35 40 20 25 29 34 18 23 28 33 30 34 38 43 21 27 33 38 12 19 26 33 3 10 18 26 25 30 35 40 21 26 30 35 20 25 29 34 29 22 9 3 25 34 28 17 5 30 38 34 24 14 35 43 39 32 22 40 room attenuation 8 dB (red 25m 2 - sab): 21 19 26 24 30 29 35 34 LpA - 4dB. Product Code The diffuser shall be made of painted steel with a DTR-D-A white (RAL 9010) colour. The flow pattern of the diffuser shall be adjustable in D = Diameter of duct connection up to three directions using deflector panels. Option 1; no balancing plenum A = Diffuser size The diffuser shall have a galvanised steel casing with D=100: 300, 600 a spigot with integral gasket for connection to circular D=125: 300, 600 duct. D=160: 450, 600 The diffuser shall have a detachable perforated front D=200: 450, 600 panel that provides access to the duct. D=250: 600 D=315: 600 100, 125, 160, 200, 250, 315 Option 2; option with balancing plenum The diffuser shall be connected to a balancing plenum Specifics and accessories equipped with a measurement and adjustment module. CO = Colour The diffuser shall have a detachable perforated front W White panel to provide access to the measurement and X Special colour adjustment module in the plenum. The balancing plenum shall have a spigot with integral Code example gasket for air-tight duct connection. The balancing plenum shall comprise sound DTR-100-300, CO=W attenuation material made of polyester fiber with a washable surface. Sub products DTR - Perforated Ceiling til Diffuser Perforeret diffusor loftsmontage 11 TRI Plenum (Diffusers) DP Deflection panel Halton reserves the right to alter products without notice Suggested Specifications