22mm TW Series

Transcription

22mm TW Series
TW_EP1070.book Page 1 Wednesday, January 19, 2005 10:49 AM
ø22mm
TW Series
Control Units
TW_EP1070.book Page 2 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Control Units (Selection Guides)
Function
Category
Flush
Extended
Pushbutton
Extended w/Full Shroud
Momentary/Maintained
ø29mm Mushroom
ø40mm Mushroom
ABW1
AOW1
8
ABW2
AOW2
8
ABFW2
AOFW2
8
ABW3
AOW3
8
ABW4
AOW4
9
Shape
Type
Page
Function
Category
Pushbutton
ø40mm Mushroom
w/Full Shroud
Momentary
ø29mm Mushroom
ø40mm Mushroom
ø40mm Mushroom
ø29mm Mushroom
Pushlock Turn Reset
Pushlock Turn Reset
Push Turn Lock
Pushlock Key Reset
ABGW4
9
AVW3
9
AVW4
9
AJW4
9
AXW3
9
Shape
Type
Page
Function
Category
ø40mm Mushroom
Pushlock Key Reset
Pushbutton
ø40mm Mushroom
Square Flush
Square Extended
Push Pull
Momentary/Maintained
Shape
Type
AXW4
AYW4
Page
10
10
Function
Category
ABQW1
AOQW1
10
Pilot Light
Flush
(Non-marking/Marking)
Dome
Square Flush
(Marking)
APW2
UPQW1B
11
11
Shape
Type
Page
2
APW1
APW1B
11
ABQW2
AOQW2
10
TW_EP1070.book Page 3 Wednesday, January 19, 2005 10:49 AM
TW Series Control Units (Selection Guides) ø22
Function
Category
Illuminated Pushbutton (LED/Incandescent)
Extended
Extended w/Full Shroud
Square Extended
ø29mm Mushroom
(Non-marking/Marking) (Non-marking/Marking)
(Marking)
Pushlock Turn Reset
ø40mm Mushroom
Pushlock Turn Reset
Shape
Type
Page
Function
Category
ALW2, ALW2B,
AOLW2, AOLW2B
13, 14
ALFW2, AOLFW2
ALFW2B, AOLFW2B
15, 16
ALQW2B
AOLQW2B
17
AVLW3
AVLW3B
18
AVLW4
AVLW4B
19
Illuminated Pushbutton (Incandescent)
ø29mm Mushroom
ø40mm Push-Pull
(Non-marking/Marking)
Shape
Type
Page
ALW3, ALW3B,
AOLW3, AOLW3B
18
Knob
Lever
Key
Illuminated Selector
Switch
(LED/Incandescent)
Knob
ASW
22
ASW∗L
23
ASW∗K
24
ASLW
25, 26
Function
Category
AYLW4
AYLW4B
19
Selector Switch
Shape
Type
Page
3
TW_EP1070.book Page 4 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Control Units
General-purpose control units for various applications
Heavy-duty type for high-level protection against
harsh environment
Low Voltage Directive
EMC Directive
• Highly reliable HW contact blocks are used.
• Degree of protection: IP65 (IEC 60529)
• UL and CSA approved, EN compliant
Safety Standards
File No. or Organization
UL
UL Listing
File No. E68961
CSA
File No. LR21451
EN
EN60947-1
EN60947-5-1
TÜV Rheinland
Specifications and Ratings
Contact Ratings
Contact Block
Rated Insulation Voltage
Rated Continuous Current
Contact Ratings by Utilization Category
IEC 60947-5-1
600V
10A
AC-15 (A600)
DC-13 (P600)
Characteristics
• Contact Ratings by Utilization Category
Operational Voltage
AC
Operational 50/60 Hz
Current
DC
AC-12
AC-15
DC-12
DC-13
Control of resistive loads and solid state loads
Control of electromagnetic loads (> 72 VA)
Control of resistive loads and solid state loads
Control of electromagnets
24V
10A
10A
8A
4A
48V
—
—
4A
2A
50V
10A
7A
—
—
110V
10A
5A
2.2A
1.1A
220V
6A
3A
1.1A
0.6A
440V
2A
1A
—
—
Minimum applicable load: 3V AC/DC, 5 mA (applicable range may vary with operating conditions and load types)
For the control units listed below, the rated current (load switching current) is reduced to a half of the rated operational current of the
contact block. The rated insulation voltage (600V) and the rated thermal current (10A) remain unchanged.
• Selector switches and illuminated selector switches with contact code 2S, 3S, 4S, 2R, or 4R.
HW-C (Contact Block)
• M3.5 terminal screw
2-way wiring possible
• Snap-fit groove
• Double-break rolling
action silver contacts
with raked surface
• Fitting groove
• Alkali-resistant
66 nylon housing
• Contact Block Types
• Push rod
Color-coded for
different contacts
Contact
NO
NC
NO (early make) NC (late break)
Housing
Blue Purple red
Blue
Purple red
Push Rod Green
Red
Black
White
• Snap-fit latch
A maximum of four contact
blocks in two layers can
mount on the operator.
Incandescent Lamp Ratings (LS Type)
Type No.
Lamp Base
Rated Voltage
Wattage
Voltage Marking
LS-6
LS-8
LS-2
BA9S/13
6V AC/DC
12V AC/DC
18V AC/DC
1W (6.3V)
1W (18V)
1W (24V)
Die stamped on the base
Approx. 1,000 hours minimum
Life (reference value)
(mean value when used on the rated voltage)
4
LS-3
24V AC/DC
1W (30V)
TW_EP1070.book Page 5 Wednesday, January 19, 2005 10:49 AM
TW Series Control Units ø22
LED Lamp Ratings (LSTD Type)
LSTD-6➁
LSTD-1➁
LSTD-2➁
BA9S/13
6V AC/DC
12V AC/DC
24V AC/DC
6V AC/DC ±10%
12V AC/DC ±10%
24V AC/DC ±10%
A, R, W, Y: 17 mA,
G, PW, S: 8 mA
11 mA
11 mA
A, R, W, Y: 14 mA,
G, PW, S: 5.5 mA
10 mA
10 mA
A (amber), G (green), PW (pure white), R (red), S (blue), W (white), Y (yellow)
Same as illumination color
Die stamped on the base
Approx. 50,000 hours (The luminance reduces to 50% the initial intensity when used on complete DC.)
A, R, W, Y
Type No.
Lamp Base
Rated Voltage
Voltage Range
AC
DC
Current Draw
Color Code ➁
Lamp Base Color
Voltage Marking
Life (reference value)
Internal Circuit
G, PW, S
LED Chip
Protection Diode
Zener Diode
Specifications
Operating Temperature
Storage Temperature
Operating Humidity
Contact Resistance
Insulation Resistance
Dielectric Strength
Vibration Resistance
Shock Resistance
Mechanical Life (minimum operations)
Electrical Life (minimum operations)
–25 to +50°C (no freezing)
–40 to +80°C
45 to 85% RH (no condensation)
50 mΩ maximum (initial value)
100 MΩ minimum (500V DC megger)
Between live and dead metal parts: 2,500V AC, 1 minute
(Full voltage type illuminated units: 2,000V AC, 1 minute)
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Damage limits:
1,000 m/s2
Operating extremes: 100 m/s2
Pushbuttons, Illuminated pushbuttons
Momentary:
5,000,000
Others:
500,000
Selector switches:
500,000
Illuminated selector switches: 500,000
Pushbuttons:
500,000 (switching frequency 1,800 operations/h, duty ratio 40%)
Illuminated pushbuttons:
500,000 (switching frequency 1,800 operations/h, duty ratio 40%)
Selector switches:
500,000 (switching frequency 1,200 operations/h, duty ratio 40%)
Mounting Hole Layout
R0.8 max.
ø22
50
+0
.
0 4
(45 min.)
.3
+0.2
0
(Note 1)
24.1 +0.4
0
3.2
30 (Note 2)
Note 1: The 3.2 mm recess is for preventing rotation and is not necessary when the nameplate or anti-rotation
ring is not used.
Note 2: The minimum mounting centers are applicable to switches with one layer of contact blocks (two contact
blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers in
consideration of convenience for wiring.
• ø40mm mushroom: 40 mm minimum
• 2-position, 3-position lever type selector switch: 39 mm minimum
• 4-position, 5-position lever type selector switch: 50 mm minimum
Degree of Protection
Type No.
A∗∗∗∗
Unit
NEMA ICS 6-110
IEC 60529
Pushbuttons, pilot lights, illuminated pushbutons, and selector switches
Type 1, 2, 3, 3R, (3S), 4, 5, 12,13 IP65
Illuminated selector switches, key pushbuttons, key reset pushbuttons, and
key selector switches
Type 1, 2, 3R, 5, 12, 13
IP54
Note: (3S) of NEMA ICS 6-110 applies to the pilot lights with round lens.
5
TW_EP1070.book Page 6 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Control Units (Ordering Information)
Ordering Information
• Specify an operator or lens color code in the Type No.
• Full voltage type illuminated units are not supplied with a
lamp. Order LED or incandescent lamps separately.
Transformer and DC-DC converter type illuminated units
contain an LED or incandescent lamp.
Rated Voltage
100/110V AC
200/220V AC
110V DC
LED Lamp
LSTD-6➁
LSTD-6➁
LSTD-6➁
• When a terminal cover is required, order an applicable
terminal cover referring to page 30.
Incandescent
LS-6
LS-6
LS-6
• All standard units are UL, CSA, EN, and TÜV approved.
The Type No. development charts shown below can be used to specify control units other than those listed on the following
pages. Gold-plated silver contacts are also available.
Pushbuttons
Illuminated Pushbuttons
ABW1 11 R - MAU
ALFW2 116 13 D R - MAU
Optional contact
MAU: Gold-plated silver contact
Button color code
Contact arrangement code
10: 1NO
01: 1NC
11: 1NO-1NC
20: 2NO
02: 2NC
21: 2NO-1NC
12: 1NO-2NC
30: 3NO
03: 3NC
31: 3NO-1NC
22: 2NO-2NC
13: 1NO-3NC
40: 4NO
04: 4NC
Note:
• Push-pull type AYW4 can have a maximum of two contact blocks.
Pilot Lights
APW2 116 D R
Lens color code
Lamp type
D:
LED (Transformer type only)
(blank): Incandescent
Operating voltage code
99: Full voltage
16: Transformer (100/110V AC)
116: Transformer (115V AC)
126: Transformer (120V AC)
26: Transformer (200/220V AC)
236: Transformer (230V AC)
246: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
16D: DC-DC converter (110V DC)
Note:
• Full voltage type is not supplied with a lamp.
• Transformer and DC-DC converter types contain an LED lamp
(LSTD-6➁) or incandescent lamp (LS-6).
6
Optional contact
MAU: Gold-plated silver contact
Lens color code
Lamp type
D:
LED (Transformer type only)
(blank): Incandescent
Contact arrangement code
10: 1NO
01: 1NC
11: 1NO-1NC 20: 2NO
02: 2NC
21: 2NO-1NC
12: 1NO-2NC 30: 3NO
03: 3NC
31: 3NO-1NC
22: 2NO-2NC 13: 1NO-3NC
40: 4NO
04: 4NC
Operating voltage code
99:
Full voltage
16:
Transformer (100/110V AC)
116: Transformer (115V AC)
126: Transformer (120V AC)
26:
Transformer (200/220V AC)
236: Transformer (230V AC)
246: Transformer (240V AC)
386: Transformer (380V AC)
46:
Transformer (400/440V AC)
486: Transformer (480V AC)
16∗D: DC-DC converter (110V DC)
Note:
• Push-pull type AYLW4 can have a maximum of two contact blocks.
• Transformer type and DC-DC converter type cannot have an odd
number of contact blocks, such as 1NO, 1NC, 3NO, 2NO-1NC,
1NO-2NC, and 3NC.
TW_Spec-Ordering Page 7 Monday, January 24, 2005 1:28 PM
TW Series Control Units (Ordering Information) ø22
Selector Switch
Illuminated Selector Switch
ASW 2 L 11 - MAU
ASLW 2 16 22 D R - MAU
Optional contact
MAU: Gold-plated silver contact
Contact arrangement code
Operator type
(blank): Knob
L:
Lever
Number of positions
Note:
• See pages 26 to 28 for contact arrangement codes.
Key Selector Switch
ASW 2 K 20 B - MAU
Optional contact
MAU: Gold-plated silver contact
Key removable position code
2-position
• Maintained
(blank): Removable in all positions
B:
Removable in left only
C:
Removable in right only
• Spring return from right
(blank): Removable in left only
• Spring return from left
(blank): Removable in right only
3-position
• Maintained
(blank): Removable in all positions
B:
Removable in left and center
C:
Removable in right and center
D:
Removable in center only
E:
Removable in right and left
G:
Removable in left only
H:
Removable in right only
• Spring return from right
(blank): Removable in left and center
D:
Removable in center only
G:
Removable in left only
• Spring return from left
(blank): Removable in right and center
D:
Removable in center only
H:
Removable in right only
• Spring return two-way
(blank): Removable in center only
Contact arrangement code
Number of positions
Optional contact
MAU: Gold-plated silver contact
Lens color code
Lamp type
D:
LED (Transformer type only)
(blank): Incandescent
Contact arrangement code
Operating voltage code
99: Full voltage
16: Transformer (100/110V AC)
156: Transformer (115V AC)
136: Transformer (120V AC)
26: Transformer (200/220V AC)
236: Transformer (230V AC)
256: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
Number of positions
Note:
• Full voltage type is not supplied with a lamp.
• Transformer type contains an LED lamp (LSTD-6➁) or incandescent lamp (LS-6).
• See pages 27 to 29 for contact arrangement codes.
Note:
• See pages 27 to 29 for contact arrangement codes.
• The key cannot be removed in the return position.
7
TW_EP1070.book Page 8 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Pushbuttons
Flush / Extended / Extended w/Full Shroud / Mushroom Types
Extended with Full Shroud
ABFW2
AOFW2
Momentary
Maintained
ø29mm Mushroom
ABW3
AOW3
Momentary
Maintained
37
30
Panel Thickness 1 to 6
Specify a button
color code in
place of ➀ in the
Type No.
B:
G:
R:
S:
W:
Y:
black
green
red
blue
white
yellow
37
M3.5 Terminal
Screws
• Specify a button color code in place of ➀ in the Type No.
• Round bezel and shroud (metal): Mat aluminum color
• Pushbuttons with one or three contact blocks contain a dummy block.
• Other contact arrangements and gold-plated silver contacts are also available. See page 6.
8
ø29
48.5 (1-2 blocks) 13
68.5 (3-4 blocks)
48.5 (1-2 blocks) 13
30
68.5 (3-4 blocks)
19
M3.5 Terminal
Screws
Panel Thickness 1 to 6
37
Maintained
Panel Thickness 1 to 6
48.5 (1-2 blocks) 19.5
30
68.5 (3-4 blocks)
M3.5 Terminal
Screws
Panel Thickness 1 to 6
48.5 (1-2 block)
68.5 (3-4 blocks)
37
Momentary
M3.5 Terminal
Screws
ø29
Extended
ABW2
AOW2
Dimensions (mm)
ø29
Maintained
ABW110➀
ABW101➀
ABW111➀
ABW120➀
ABW102➀
ABW122➀
AOW110➀
AOW101➀
AOW111➀
AOW120➀
AOW102➀
AOW122➀
ABW210➀
ABW201➀
ABW211➀
ABW220➀
ABW202➀
ABW222➀
AOW210➀
AOW201➀
AOW211➀
AOW220➀
AOW202➀
AOW222➀
ABFW210➀
ABFW201➀
ABFW211➀
ABFW220➀
ABFW202➀
ABFW222➀
AOFW210➀
AOFW201➀
AOFW211➀
AOFW220➀
AOFW202➀
AOFW222➀
ABW310➀
ABW301➀
ABW311➀
ABW320➀
ABW302➀
ABW322➀
AOW310➀
AOW301➀
AOW311➀
AOW320➀
AOW302➀
AOW322➀
➀ Button Color
Code
ø29
Momentary
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
Type No.
ø24
Flush
ABW1
AOW1
Contact
ø24
Operation
Type
ø24
Shape
13
22.5
30
TW_EP1070.book Page 9 Wednesday, January 19, 2005 10:49 AM
TW Series Pushbuttons ø22
Mushroom / Pushlock Turn Reset / Push Turn Lock / Pushlock Key Reset Types
ABGW411➀
2NO
ABGW420➀
ø29mm Pushlock Turn Reset
AVW3 (Note)
2NC
ABGW402➀
2NO-2NC
ABGW422➀
1NO
AVW310➀
1NC
AVW301➀
1NO-1NC
AVW311➀
2NO
AVW320➀
2NC
AVW302➀
2NO-2NC
ø40mm Pushlock Turn Reset
AVW4 (Note)
ø40mm Push Turn Lock
AJW4
1NO
AVW410➀
1NC
AVW401➀
1NO-1NC
AVW411➀
2NO
AVW420➀
2NC
AVW402➀
2NO-2NC
AVW422➀
1NO
AJW410➀
1NC
AJW401➀
1NO-1NC
AJW411➀
2NO
AJW420➀
2NC
AJW402➀
2NO-2NC
AJW422➀
1NO
AXW310R
1NC
AXW301R
1NO-1NC
AXW311R
2NO
AXW320R
2NC
AXW302R
2NO-2NC
AXW322R
37
ø40
Panel Thickness 1 to 6
48.5 (1-2 blocks)
68.5 (3-4 blocks)
30
23
M3.5 Terminal
Screws
Panel Thickness
1 to 6
Reset Angle 75°
48.5 (1-2 blocks) 13
30
22.5
68.5 (3-4 blocks)
R: red
Y: yellow
M3.5 Terminal
Screws
Panel Thickness
1 to 6
Reset Angle 75°
48.5 (1-2 blocks) 13
68.5 (3-4 blocks)
M3.5 Terminal
Screws
B:
G:
R:
Y:
30
22.5
Panel Thickness
1 to 6
Reset Angle 75°
black
green
red
yellow
LO
SH
CK
ø29mm Pushlock Key Reset
AXW3 (Note)
AVW322➀
M3.5 Terminal
Screw
37
1NO-1NC
Momentary
black
green
red
blue
white
yellow
30
22.5
37
ABGW401➀
B:
G:
R:
S:
W:
Y:
48.5 (1-2 blocks) 13
68.5 (3-4 blocks)
37
1NC
Specify a button
color code in
place of ➀ in the
Type No.
37
ABGW410➀
Panel Thickness 1 to 6
48.5 (1-2 blocks) 13
68.5 (3-4 blocks)
M3.5 Terminal
Screws
30
22.5
Panel Thickness Reset
1 to 6
(unlock)
Red only
45 °
37
1NO
M3.5 Terminal
Screws
PU
ø40mm Mushroom
w/Full Shroud
ABGW4
Dimensions (mm)
ø29
Maintained
ABW410➀
ABW401➀
ABW411➀
ABW420➀
ABW402➀
ABW422➀
AOW410➀
AOW401➀
AOW411➀
AOW420➀
AOW402➀
AOW422➀
➀ Button Color
Code
ø46
Momentary
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
Type No.
ø29
ø40mm Mushroom
ABW4
AOW4
Contact
ø40
Operation
Type
ø40
Shape
13
48.5 (1-2 blocks)
68.5 (3-4 blocks)
25
47
30
• Specify a button color code in place of ➀ in the Type No.
• Round bezel (metal): Mat aluminum color
• Pushbuttons with one or three contact blocks contain a dummy block.
• Other contact arrangements and gold-plated silver contacts are also available. See page 6.
Note: AVW3, AVW4, and AXW3 pushbuttons cannot be used as emergency stop switches. When emergency stop switches are required, use
XW or HW series pushbuttons (ISO 13850 and IEC 60947-5-5 compliant).
9
TW_EP1070.book Page 10 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Pushbuttons
Pushlock Key Reset / Push-Pull / Square Flush / Square Extended
Type No.
1NO
AXW410R
1NC
AXW401R
1NO-1NC
AXW411R
2NO
AXW420R
2NC
AXW402R
➀ Button Color
Code
Dimensions (mm)
M3.5 Terminal
Screws
Panel Thickness
1 to 6
Reset
(unlock)
Red only
45 °
37
Contact
ø40
Operation
Type
ø40mm Mushroom Push Lock Key Reset
AXW4
Shape
13
48.5 (1-2 blocks)
25
68.5 (3-4 blocks)
2NO
AYW420➀
2NC
Square Flush
ABQW1
AOQW1
Momentary
Maintained
Square Extended
ABQW2
AOQW2
Momentary
Maintained
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
1NO
1NC
1NO-1NC
2NO
2NC
2NO-2NC
13
48.5 (1-2 blocks)
68.5 (3-4 blocks)
AYW402➀
ABQW110➀
ABQW101➀
ABQW111➀
ABQW120➀
ABQW102➀
ABQW122➀
AOQW110➀
AOQW101➀
AOQW111➀
AOQW120➀
AOQW102➀
AOQW122➀
ABQW210➀
ABQW201➀
ABQW211➀
ABQW220➀
ABQW202➀
ABQW222➀
AOQW210➀
AOQW201➀
AOQW211➀
AOQW220➀
AOQW202➀
AOQW222➀
M3.5 Terminal
Screws
B:
G:
R:
S:
W:
Y:
black
green
red
blue
white
yellow
• Specify a button color code in place of ➀ in the Type No.
• Round bezel (metal): Mat aluminum color
• Square bezel (plastic): Black
• Pushbuttons with one or three contact blocks contain a dummy block.
• Other contact arrangements and gold-plated silver contacts are also available. See page 6.
• Contact Statuses of Push-Pull Switch
Contact
ø40mm Mushroom
Push-Pull Switch
Push
Pull
1NO
1NC
1NO-1NC
2NO
2NC
• Note: Push-pull switch can have a maximum of two contact blocks.
10
37
AYW411➀
25
30
30.5
Panel Thickness
1 to 6
37
1NO-1NC
48.5 (1-2 blocks) 13
30
68.5 (3-4 blocks)
M3.5 Terminal
Screws
Panel Thickness
1 to 6
37
AYW401➀
Panel Thickness
1 to 6
ø40
1NC
M3.5 Terminal
Screws
25
AYW410➀
30
1NO
ø40mm Mushroom Push-Pull
AYW4
30
47
30
AXW422R
25
2NO-2NC
48.5 (1-2 blocks) 13
68.5 (3-4 blocks)
20
30
TW_EP1070.book Page 11 Wednesday, January 19, 2005 10:49 AM
TW Series Pilot Lights ø22
Round Flush / Dome / Square Flush Types
Shape
Round Flush
APW1
Lamp
Input Type
Without Lamp Full Voltage
APW199➁
Transformer
APW1➂D➁
DC-DC Converter∗
APW11DD➁
LED
Incandescent
Round Flush (Marking)
APW1B
Transformer
Without Lamp Full Voltage
APW1➂➁
APW1B99➁
Transformer
APW1B➂D➁
DC-DC Converter∗
APW1B16DD➁
LED
Incandescent
Dome
APW2
Transformer
Without Lamp Full Voltage
APW1B➂➁
APW299➁
Transformer
APW2➂D➁
DC-DC Converter∗
APW216DD➁
LED
Incandescent
Square Flush (Marking)
APQW1B
Transformer
Without Lamp Full Voltage
APW2➂➁
APQW1B99➁
Transformer
APQW1B➂D➁
DC-DC Converter∗
APQW1B16DD➁
LED
Incandescent
Transformer
➁ Lens/LED
Color Code
Type No.
APQW1B➂➁
A:
G:
PW:
R:
S:
W:
Y:
amber
green
pure white
red
blue
white
yellow
A:
G:
R:
S:
W:
amber
green
red
blue
white
A:
G:
PW:
R:
S:
W:
Y:
amber
green
pure white
red
blue
white
yellow
A:
G:
R:
S:
W:
amber
green
red
blue
white
A:
G:
PW:
R:
S:
W:
Y:
amber
green
pure white
red
blue
white
yellow
A:
G:
R:
S:
W:
amber
green
red
blue
white
A:
G:
PW:
R:
S:
W:
Y:
amber
green
pure white
red
blue
white
yellow
A:
G:
R:
S:
W:
amber
green
red
blue
white
➂ Operating Voltage Code
Specify an operating
voltage code in place of ➂
in the Type No.
16:
116:
126:
26:
236:
246:
386:
46:
486:
100/110V AC
115 AC
120V AC
200/220V AC
230V AC
240V AC
380V AC
400/440V AC
480V AC
• Specify a lens/LED color code in place of ➁ in the Type No.
• The white (W) lens of APW1B and APQW1B types is a combination of clear lens and white marking plate.
• Specify an operating voltage code in place of ➂ in the Type No.
• Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36.
• LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC).
• Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
• Round bezel (metal): Mat aluminum color
• Square bezel (plastic): Black
∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
11
TW_PL Page 12 Wednesday, January 19, 2005 1:37 PM
ø22 TW Series Pilot Lights
Dimensions
• Round Flush APW1
Transformer, DC-DC Converter
30
28.5
• Round Flush Marking Type APW1B
Transformer, DC-DC Converter
ø24
37
13
30
28.5
Marking plate: ø15.5 mm
13
30
17
66.5
Marking plate: ø15.5 mm
• Dome APW2
Transformer, DC-DC Converter
30
28.5
25
66.5
13
30
Marking plate:
28.5
22 mm
• Arrows indicate access directions for wiring.
TOP
M3.5
M3.5
X1
X1
X2
X2
Full Voltage Type
37
Panel Thickness 1 to 6
Transformer Type
DC-DC Converter Type
66.5
13
37
37
30
25
M3.5 Terminal
Screw
Terminal Wiring (Bottom View)
TOP
30
25
• Square Flush Marking Type APQW1B
Transformer, DC-DC Converter
Panel Thickness
1 to 6
16
13
30
• Square Flush Marking Type APQW1B
Full Voltage
28.5
ø23.6
37
13
25
28.5
Panel Thickness
1 to 6
M3.5 Terminal
Screw
ø29
ø23.6
Panel Thickness
1 to 6
ø29
• Dome APW2
Full Voltage
12
Panel Thickness
1 to 6
M3.5 Terminal
Screw
ø29
ø24
Panel Thickness
1 to 6
17
30
17
37
• Round Flush Marking Type APW1B
Full Voltage
28.5
13
66.5
17
37
ø24
37
13
ø29
28.5
Panel Thickness
1 to 6
M3.5 Terminal Screw
ø29
ø24
Panel Thickness
1 to 6
ø29
• Round Flush APW1
Full Voltage
30
16
Marking plate:
22 mm
All dimensions in mm.
TW_EP1070.book Page 13 Wednesday, January 19, 2005 10:49 AM
TW Series Illuminated Pushbuttons ø22
.
Round Extended Illuminated Pushbuttons
Shape
Round Extended
ALW2
AOLW2
Operation Type
Lamp
Without Lamp
Input Type
Full Voltage
Transformer
Momentary
LED
DC-DC Converter∗
Incandescent
Transformer
Without Lamp
Full Voltage
Transformer
Maintained
LED
DC-DC Converter∗
Incandescent
Transformer
Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
Type No.
ALW29911➁
ALW29920➁
ALW29922➁
ALW2➂11D➁
ALW2➂20D➁
ALW2➂22D➁
ALW21611DD➁
ALW21620DD➁
ALW21622DD➁
ALW2➂11➁
ALW2➂20➁
ALW2➂22➁
AOLW29911➁
AOLW29920➁
AOLW29922➁
AOLW2➂11D➁
AOLW2➂20D➁
AOLW2➂22D➁
AOLW21611DD➁
AOLW21620DD➁
AOLW21622DD➁
AOLW2➂11➁
AOLW2➂20➁
AOLW2➂22➁
• Color Code and Operating Voltage Code
LED Illuminated Type
➁ Lens/LED Color Code
Specify a lens/LED color code in
place of ➁ in the Type No.
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
•
•
•
∗
Incandescent Illuminated Type
➂ Operating Voltage Code
➁ Lens Color Code
Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No.
➁ in the Type No.
16: Transformer (100/110V AC)
A: amber
116: Transformer (115V AC)
G: green
126: Transformer (120V AC)
R: red
26: Transformer (200/220V AC)
S: blue
236: Transformer (230V AC)
W: white
246: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36.
LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC).
Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
13
TW_EP1070.book Page 14 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Illuminated Pushbuttons
Round Extended Illuminated Pushbuttons (Marking Type)
Shape
Round Extended (Marking)
ALW2B
AOLW2B
Operation Type
Lamp
Without Lamp
Input Type
Full Voltage
Transformer
Momentary
LED
DC-DC Converter∗
Incandescent
Transformer
Without Lamp
Full Voltage
Transformer
Maintained
LED
DC-DC Converter∗
Incandescent
Transformer
Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
Type No.
ALW2B9911➁
ALW2B9920➁
ALW2B9922➁
ALW2B➂11D➁
ALW2B➂20D➁
ALW2B➂22D➁
ALW2B1611DD➁
ALW2B1620DD➁
ALW2B1622DD➁
ALW2B➂11➁
ALW2B➂20➁
ALW2B➂22➁
AOLW2B9911➁
AOLW2B9920➁
AOLW2B9922➁
AOLW2B➂11D➁
AOLW2B➂20D➁
AOLW2B➂22D➁
AOLW2B1611DD➁
AOLW2B1620DD➁
AOLW2B1622DD➁
AOLW2B➂11➁
AOLW2B➂20➁
AOLW2B➂22➁
• Color Code and Operating Voltage Code
LED Illuminated Type
➁ Lens/LED Color Code
Specify a lens/LED color code in
place of ➁ in the Type No.
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
•
•
•
∗
Incandescent Illuminated Type
➂ Operating Voltage Code
➁ Lens Color Code
Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No.
➁ in the Type No.
16: Transformer (100/110V AC)
A: amber
116: Transformer (115V AC)
G: green
126: Transformer (120V AC)
R: red
26: Transformer (200/220V AC)
S: blue
236: Transformer (230V AC)
W: white
246: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36.
LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC).
Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
14
TW_EP1070.book Page 15 Wednesday, January 19, 2005 10:49 AM
TW Series Illuminated Pushbuttons ø22
Round Extended with Full Shroud Illuminated Pushbuttons
Shape
Round Extended
With Full Shroud
ALFW2
AOLFW2
Operation Type
Lamp
Without Lamp
Input Type
Full Voltage
Transformer
Momentary
LED
DC-DC Converter∗
Incandescent
Transformer
Without Lamp
Full Voltage
Transformer
Maintained
LED
DC-DC Converter∗
Incandescent
Transformer
Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
Type No.
ALFW29911➁
ALFW29920➁
ALFW29922➁
ALFW2➂11D➁
ALFW2➂20D➁
ALFW2➂22D➁
ALFW21611DD➁
ALFW21620DD➁
ALFW21622DD➁
ALFW2➂11➁
ALFW2➂20➁
ALFW2➂22➁
AOLFW29911➁
AOLFW29920➁
AOLFW29922➁
AOLFW2➂11D➁
AOLFW2➂20D➁
AOLFW2➂22D➁
AOLFW21611DD➁
AOLFW21620DD➁
AOLFW21622DD➁
AOLFW2➂11➁
AOLFW2➂20➁
AOLFW2➂22➁
• Color Code and Operating Voltage Code
LED Illuminated Type
➁ Lens/LED Color Code
Specify a lens/LED color code in
place of ➁ in the Type No.
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
•
•
•
∗
Incandescent Illuminated Type
➂ Operating Voltage Code
➁ Lens Color Code
Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No.
➁ in the Type No.
16: Transformer (100/110V AC)
A: amber
116: Transformer (115V AC)
G: green
126: Transformer (120V AC)
R: red
26: Transformer (200/220V AC)
S: blue
236: Transformer (230V AC)
W: white
246: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36.
LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC).
Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
15
TW_EP1070.book Page 16 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Illuminated Pushbuttons
Round Extended with Full Shroud Illuminated Pushbuttons (Marking Type)
Shape
Round Extended (Marking)
With Full Shroud
ALFW2B
AOLFW2B
Operation Type
Lamp
Without Lamp
Input Type
Full Voltage
Transformer
Momentary
LED
DC-DC Converter∗
Incandescent
Transformer
Without Lamp
Full Voltage
Transformer
Maintained
LED
DC-DC Converter∗
Incandescent
Transformer
Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
Type No.
ALFW2B9911➁
ALFW2B9920➁
ALFW2B9922➁
ALFW2B➂11D➁
ALFW2B➂20D➁
ALFW2B➂22D➁
ALFW2B1611DD➁
ALFW2B1620DD➁
ALFW2B1622DD➁
ALFW2B➂11➁
ALFW2B➂20➁
ALFW2B➂22➁
AOLFW2B9911➁
AOLFW2B9920➁
AOLFW2B9922➁
AOLFW2B➂11D➁
AOLFW2B➂20D➁
AOLFW2B➂22D➁
AOLFW2B1611DD➁
AOLFW2B1620DD➁
AOLFW2B1622DD➁
AOLFW2B➂11➁
AOLFW2B➂20➁
AOLFW2B➂22➁
• Color Code and Operating Voltage Code
LED Illuminated Type
➁ Lens/LED Color Code
Specify a lens/LED color code in
place of ➁ in the Type No.
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
•
•
•
∗
Incandescent Illuminated Type
➂ Operating Voltage Code
➁ Lens Color Code
Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No.
➁ in the Type No.
16: Transformer (100/110V AC)
A: amber
116: Transformer (115V AC)
G: green
126: Transformer (120V AC)
R: red
26: Transformer (200/220V AC)
S: blue
236: Transformer (230V AC)
W: white
246: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36.
LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC).
Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
16
TW_EP1070.book Page 17 Wednesday, January 19, 2005 10:49 AM
TW Series Illuminated Pushbuttons ø22
Square Extended Illuminated Pushbuttons (Marking Type)
Shape
Square Extended (Marking)
ALQW2B
AOLQW2B
Operation Type
Lamp
Without Lamp
Input Type
Full Voltage
Transformer
Momentary
LED
DC-DC Converter∗
Incandescent
Transformer
Without Lamp
Full Voltage
Transformer
Maintained
LED
DC-DC Converter∗
Incandescent
Transformer
Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
Type No.
ALQW2B9911➁
ALQW2B9920➁
ALQW2B9922➁
ALQW2B➂11D➁
ALQW2B➂20D➁
ALQW2B➂22D➁
ALQW2B1611DD➁
ALQW2B1620DD➁
ALQW2B1622DD➁
ALQW2B➂11➁
ALQW2B➂20➁
ALQW2B➂22➁
AOLQW2B9911➁
AOLQW2B9920➁
AOLQW2B9922➁
AOLQW2B➂11D➁
AOLQW2B➂20D➁
AOLQW2B➂22D➁
AOLQW2B1611DD➁
AOLQW2B1620DD➁
AOLQW2B1622DD➁
AOLQW2B➂11➁
AOLQW2B➂20➁
AOLQW2B➂22➁
• Color Code and Operating Voltage Code
LED Illuminated Type
➁ Lens/LED Color Code
Specify a lens/LED color code in
place of ➁ in the Type No.
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
•
•
•
∗
Incandescent Illuminated Type
➂ Operating Voltage Code
➁ Lens Color Code
Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No.
➁ in the Type No.
16: Transformer (100/110V AC)
A: amber
116: Transformer (115V AC)
G: green
126: Transformer (120V AC)
R: red
26: Transformer (200/220V AC)
S: blue
236: Transformer (230V AC)
W: white
246: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36.
LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC).
Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC).
17
TW_EP1070.book Page 18 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Illuminated Pushbuttons
Mushroom (ø29) Illuminated Pushbuttons
Shape
ø29 Mushroom
ALW3
AOLW3
Operation Type
Lamp
Input Type
Contact
Type No.
Without Lamp
Full Voltage
ALW39911➁
Incandescent
Transformer
ALW3➂11➁
Without Lamp
Full Voltage
AOLW39911➁
Incandescent
Transformer
Momentary
Maintained
ø29 Mushroom (Marking Type)
ALW3B
AOLW3B
AOLW3➂11➁
1NO-1NC
Without Lamp
Full Voltage
ALW3B9911➁
Incandescent
Transformer
ALW3B➂11➁
Without Lamp
Full Voltage
AOLW3B9911➁
Incandescent
Transformer
AOLW3B➂11➁
Without Lamp
Full Voltage
LED
Transformer
Incandescent
Transformer
Without Lamp
Full Voltage
LED
Transformer
Incandescent
Transformer
Momentary
Maintained
ø29 Mushroom Pushlock Turn Reset
AVLW3
ø29 Mushroom Pushlock Turn Reset (Marking Type)
AVLW3B
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO
1NC
1NO-1NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
• Color Code and Operating Voltage Code
Incandescent Illuminated Type
➂ Operating Voltage Code
➁ Lens Color Code
Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No.
➁ in the Type No.
16: Transformer (100/110V AC)
A: amber
116: Transformer (115V AC)
G: green
126: Transformer (120V AC)
R: red
26: Transformer (200/220V AC)
S: blue
236: Transformer (230V AC)
W: white
246: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
• Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36.
• LED illuminated transformer types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC).
• Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
18
AVLW39911R
AVLW39920R
AVLW39922R
AVLW3➂11DR
AVLW3➂20DR
AVLW3➂22DR
AVLW3➂11R
AVLW3➂20R
AVLW3➂22R
AVLW3B9911R
AVLW3B9920R
AVLW3B9922R
AVLW3B➂11DR
AVLW3B➂20DR
AVLW3B➂22DR
AVLW3B➂11R
AVLW3B➂20R
AVLW3B➂22R
TW_EP1070.book Page 19 Wednesday, January 19, 2005 10:49 AM
TW Series Illuminated Pushbuttons ø22
Mushroom (ø40 mm) Illuminated Pushbuttons
Shape
ø40 Mushroom Pushlock Turn Reset
AVLW4
Lamp
Input Type
Without Lamp
Full Voltage
LED
Transformer
Incandescent
Transformer
ø40 Mushroom Pushlock Turn Reset (Marking Type)
AVLW4B
Without Lamp
Full Voltage
ø40 Mushroom Push Pull
AYLW4
(2-position
maintained)
LED
Transformer
Incandescent
Transformer
Without Lamp
Incandescent
ø40 Mushroom Push Pull (Marking Type)
AYLW4B
(2-position
maintained)
Without Lamp
Incandescent
Full Voltage
Contact
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
1NO
1NC
1NO-1NC
1NO-1NC
2NO
2NO-2NC
1NO-1NC
2NO
2NO-2NC
Type No.
AVLW49911R
AVLW49920R
AVLW49922R
AVLW4➂11DR
AVLW4➂20DR
AVLW4➂22DR
AVLW4➂11R
AVLW4➂20R
AVLW4➂22R
AVLW4B9911R
AVLW4B9920R
AVLW4B9922R
AVLW4B➂11DR
AVLW4B➂20DR
AVLW4B➂22DR
AVLW4B➂11R
AVLW4B➂20R
AVLW4B➂22R
1NO-1NC
AYLW49911➁
2NO
AYLW49920➁
2NO-2NC
AYLW49922➁
1NO-1NC
AYLW4➂11➁
2NO
AYLW4➂20➁
1NO
AYLW4B9911➁
1NC
AYLW4B9920➁
1NO-1NC
AYLW4B9922➁
1NO-1NC
AYLW4B➂11➁
2NO
AYLW4B➂20➁
Transformer
Full Voltage
Transformer
• Color Code and Operating Voltage Code
Incandescent Illuminated Type
➂ Operating Voltage Code
➁ Lens Color Code
Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No.
➁ in the Type No.
16: Transformer (100/110V AC)
A: amber
116: Transformer (115V AC)
G: green
126: Transformer (120V AC)
R: red
26: Transformer (200/220V AC)
S: blue
236: Transformer (230V AC)
W: white (AYLW4 only)
246: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
• Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36.
• LED illuminated transformer type contains an LED lamp (LSTD-6➁, rated voltage 6V AC/DC).
• Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
• Contact Statuses of Push-Pull Switch
Contact
ø40mm Mushroom
Push-Pull Switch
Push
Pull
1NO
1NC
1NO-1NC
2NO
2NC
Note: Push-pull switch can have a maximum of two contact blocks.
19
TW_EP1070.book Page 20 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Illuminated Pushbuttons
Dimensions (Operator)
Panel Thickness
1 to 6
37
ø29
ø24
37
25
Panel Thickness
1 to 6
ø29
ø24
Panel Thickness
1 to 6
Square Extended (marking)
ALQW2B / AOLQW2B
37
Round Extended with Full Shroud
(non-marking/marking)
ALFW2 / ALFW2B / AOLFW2 / AOLFW2B
30
Round Extended (non-marking/marking)
ALW2 / ALW2B / AOLW2 / AOLW2B
13
13
30
20
30
19
30
20
Marking plate:
Marking plate: ø15.5mm
21mm
Marking plate: ø15.5mm
ø29 Mushroom (non-marking/marking)
ALW3 / ALW3B / AOLW3 / AOLW3B
ø29 Mushroom Pushlock Turn Reset
(non-marking/marking)
AVLW3 / AVLW3B
Panel Thickness
1 to 6
Panel Thickness
1 to 6
Reset Angle: 75°
Reset Angle 75°
13
30
13
22.5
37
13
30
22.5
Marking plate: ø13.9mm
ø40
37
ø29
37
ø29
Panel Thickness
1 to 6
ø40 Mushroom Pushlock Turn Reset
(non-marking/marking)
AVLW4 / AVLW4B
22.5
Marking plate: ø13.9mm
30
Marking plate: ø13.9mm
ø40 Mushroom Push Pull
(non-marking/marking)
AYLW4 / AYLW4B
37
ø40
Panel Thickness
1 to 6
13
25
30
30.5
Marking plate: ø13.9mm
All dimensions in mm.
Terminal Arrangement (Lamp Terminal) (Bottom View)
• Arrows indicate access directions for wiring.
TOP
X1
TOP
TOP
X1
X1
X2
X2
20
X2
Full Voltage Type
Full Voltage Type
When using TW-DA1B
Full Voltage Adapter for
2 or 4 contact blocks
When using HW-DA1B
Full Voltage Adapter for
1 or 3 contact blocks
Transformer Type
DC-DC Converter Type
TW_EP1070.book Page 21 Wednesday, January 19, 2005 10:49 AM
TW Series Illuminated Pushbuttons ø22
Dimensions (Behind the Panel)
• Transformer Type
• DC-DC Converter Type
• Full Voltage Type
M3.5
Terminal Screws
Panel Thickness
1 to 6
M3.5 Terminal Screws
Panel Thickness
1 to 6
X1
X1
X2
X2
1 contact
block
48.5
When using HW-DA1B full-voltage adapter
M3.5
Terminal Screws
2 contact
blocks
Panel Thickness
1 to 6
86.5
M3.5 Terminal Screws
Panel Thickness
1 to 6
X1
X2
X1
X2
2 contact
blocks
4 contact
blocks
63.5
106.5
When using TW-DA1B full-voltage adapter
Panel Thickness
1 to 6
X2
X1
M3.5
Terminal Screws
3 contact
blocks
68.5
When using HW-DA1B full-voltage adapter
M3.5 Terminal Screws
Panel Thickness
1 to 6
X1
X2
4 contact
blocks
83.5
When using TW-DA1B full-voltage adapter
Note: For the push-pull type, a maximum of two contact blocks can be used.
All dimensions in mm.
• Contact Configuration and Codes
Contact Configuration
1NO
1 block
1NC
1NO-1NC
2 blocks
2NO
2NC
2NO-1NC
1NO-2NC
3 blocks
3NO
3NC
3NO-1NC
2NO-2NC
4 blocks
1NO-3NC
4NO
4NC
Code
10
01
11
20
02
21
12
30
03
31
22
13
40
04
21
TW_EP1070.book Page 22 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Selector Switches
90° 2-position
Panel Thickness 1 to 6
48.5 (2 blocks)
10
(1NO)
11
(1NO-1NC)
20
(2NO)
22
(2NO-2NC)
Contact
Code
20
(2NO)
02
(2NC)
45° 3-position
M3.5 Terminal
Screws
22
(2NO-2NC)
40
(4NO)
04
(4NC)
3S ★
Contact
Code
Contact
Block
Mounting
Position
Operator Position
Maintained
L
Type
L
R
L
C
1
L
37
—
R
ASW2110
ASW2210 ∗
ASW211
ASW2111
ASW2211 ∗
ASW220
ASW2120
ASW2220 ∗
ASW222
ASW2122
ASW2222 ∗
Maintained
C
R
2
Spring Return
from Right
—
Spring Return
from Left
C
Spring Return
Two-way
C
R
L
C
R
L
R
L
ASW320
ASW3120
ASW3220
ASW3320
ASW302
ASW3102
ASW3202
ASW3302
ASW322
ASW3122
ASW3222
ASW3322
ASW340
ASW3140
ASW3240
ASW3340
ASW304
ASW3104
ASW3204
ASW3304
ASW33S-243 ★
Maintained
3
4
5
—
2
3
1
4
—
Maintained
2
1
Type
R
R
NO
1
NO
2
NC
1
NC
2
NO
1
NO
2
NC
3
NC
4
NO
1
NO
2
NO
3
NO
4
NC
1
NC
2
NC
3
NC
4
NO
1
NO
2
NC
3
Dummy
4
Contact
Operator Position
Block
Mounting
Position
L
Spring Return
from Left
ASW210
L
Type
Spring Return
from Right
30
25
R
NO
1
Dummy
2
NO
1
NC
2
NO
1
NO
2
NO
1
NC
2
NO
3
NC
4
Contact
Operator Position
Block
Mounting
Position
13
68.5 (4 blocks)
Contact Arrangement Chart
Contact
Code
30° 5-position / 45° 4-position
ASW
ø29
Shape
ø24
No. of Positions
Selector Switches (Knob Operator Type)
3
4
5
—
• Contact Block Mounting Position
and Contact Arrangement Chart
Left
Center
Right
1
NC
NC
2
ASW44S-407 ★
—
4S ★
L C R
NC
3
NO
4
1 NO
NO
1
2 NO
NC
2
4S ★
ASW44S-411 ★
—
3 NC
NC
3
4 NC
NO
4
NO
1
NC
2
• For more contact
3S ★
ASW43S-461 ★
—
NC
3
arrangement chart,
Dummy
4
see pages 27 to 29.
NO
1
3
NC
2
1
4S ★
—
ASW54S-501 ★
NC
3
NO
4
• On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows.
Operator
Position
4
2
TOP
• On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated
current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged.
• Selector switches with one or three contact blocks contain a dummy block.
• Knob operator: White indicator on black knob
22
TW_EP1070.book Page 23 Wednesday, January 19, 2005 10:49 AM
TW Series Selector Switches ø22
90° 2-position
37
ø29
Panel Thickness 1 to 6
48.5 (2 blocks)
10
(1NO)
11
(1NO-1NC)
20
(2NO)
22
(2NO-2NC)
Contact
Code
20
(2NO)
02
(2NC)
45° 3-position
M3.5 Terminal
Screws
Contact Arrangement Chart
Contact
Code
22
(2NO-2NC)
40
(4NO)
04
(4NC)
3S ★
Contact
Code
30° 5-position / 45° 4-position
ASW∗L
Shape
ø25
No. of Positions
Selector Switches (Lever Operator Type)
Contact
Block
Operator Position
Maintained
L
Mounting
Position
Type
L
R
L
C
1
—
R
ASW21L10
ASW22L10 ∗
ASW2L11
ASW21L11
ASW22L11 ∗
ASW2L20
ASW21L20
ASW22L20 ∗
ASW2L22
ASW21L22
ASW22L22 ∗
Maintained
C
R
2
Spring Return
from Right
—
Spring Return
from Left
C
Spring Return
Two-way
C
R
L
C
R
L
R
L
ASW3L20
ASW31L20
ASW32L20
ASW33L20
ASW3L02
ASW31L02
ASW32L02
ASW33L02
ASW3L22
ASW31L22
ASW32L22
ASW33L22
ASW3L40
ASW31L40
ASW32L40
ASW33L40
ASW3L04
ASW31L04
ASW32L04
ASW33L04
—
—
—
ASW3L3S-243 ★
Maintained
3
4
5
Maintained
2
1
Type
L
R
NO
1
NO
2
NC
1
NC
2
NO
1
NO
2
NC
3
NC
4
NO
1
NO
2
NO
3
NO
4
NC
1
NC
2
NC
3
NC
4
NO
1
NO
2
NC
3
Dummy
4
Contact
Operator Position
Block
Mounting
Position
R
L
Spring Return
from Left
ASW2L10
L
Type
Spring Return
from Right
30
25
R
NO
1
Dummy
2
NO
1
NC
2
NO
1
NO
2
NO
1
NC
2
NO
3
NC
4
Contact
Operator Position
Block
Mounting
Position
13
68.5 (4 blocks)
2
3
1
4
3
4
5
• Contact Block Mounting Position
and Contact Arrangement Chart
Left
Center
Right
1
NC
NC
2
4S ★
ASW4L4S-407 ★
—
Operator
L C R
NC
3
Position
NO
4
1 NO
NO
1
2 NO
NC
2
4S ★
ASW4L4S-411 ★
—
3 NC
NC
3
4 NC
NO
4
4
NO
1
TOP
2
• For more contact
NC
2
3S ★
ASW4L3S-461 ★
—
arrangement
chart,
NC
3
see pages 27 to 29.
Dummy
4
NO
1
3
NC
2
1
4S ★
—
ASW5L4S-501 ★
NC
3
NO
4
• On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows.
• On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated
current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged.
• Selector switches with one or three contact blocks contain a dummy block.
• Lever operator: White indicator on black lever
23
TW_EP1070.book Page 24 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Selector Switches
Key Selector Switches
Panel Thickness 1 to 6
48.5 (2 blocks)
90° 2-position
Contact
Code
Contact
Block
Type
L
11
(1NO-1NC)
20
(2NO)
22
(2NO-2NC)
Mounting
Position
R
L
R
Spring Return
from Left
L
—
R
ASW2K10
ASW21K10
ASW22K10 ∗
ASW2K11
ASW21K11
ASW22K11 ∗
ASW2K20
ASW21K20
ASW22K20 ∗
ASW2K22
ASW21K22
ASW22K22 ∗
Maintained
L
C
Spring Return
from Right
R
L
—
Spring Return
from Left
C
C
L
Type
Spring Return
from Right
30
41
R
NO
1
Dummy
2
NO
1
NC
2
NO
1
NO
2
NO
1
NC
2
NO
3
NC
4
Contact
Operator Position
Block
10
(1NO)
Contact
Code
Maintained
Operator Position
L
Mounting
Position
13
19
68.5 (4 blocks)
Contact Arrangement Chart
37
ø24
No. of Positions
M3.5 Teminal
Screws
ø29
ASW∗K
Shape
Spring Return
Two-way
C
R
L
C
R
L
R
R
NO
1
ASW3K20
ASW31K20
ASW32K20
ASW33K20
NO
2
NC
1
02
ASW3K02
ASW31K02
ASW32K02
ASW33K02
(2NC)
NC
2
NO
1
22
NO
2
ASW3K22
ASW31K22
ASW32K22
ASW33K22
NC
(2NO-2NC)
3
NC
4
NO
1
40
NO
2
ASW3K40
ASW31K40
ASW32K40
ASW33K40
NO
(4NO)
3
NO
4
NC
1
04
NC
2
ASW3K04
ASW31K04
ASW32K04
ASW33K04
NC
(4NC)
3
NC
4
NO
1
NO
2
3S ★
ASW3K3S-243 ★
—
—
—
NC
3
Dummy
4
• On the spring-returned types, the key can be released only from the maintained position. On the maintained types, the key can be released
from every position. Key retained positions are also available. See page 7.
• On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows.
20
45° 3-position
(2NO)
• On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated
current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged.
• Key selector switches with one or three contact blocks contain a dummy block.
• Cylinder cover: Black, Cylinder: Metal
• Contact Block Mounting Position and Contact Arrangement Chart
4
Center
Left
2
L
3
1
Right
TOP
1
2
3
4
C
R
NO
NO
NC
NC
• For more contact arrangement chart, see pages 27 to 29.
24
Operator
Position
TW_EP1070.book Page 25 Wednesday, January 19, 2005 10:49 AM
TW Series Selector Switches ø22
Illuminated Selector Switches
90° 2-position
ASLW
M3.5 Terminal Screws
13
A: 63.5 (2 blocks)
83.5 (4 blocks)
Contact
Code
Contact
Block
Maintained
Operator
Position
Lamp
Input Type
L
R
30
25
A: Rated voltage 24V AC/DC
B: Rated voltage 100/110V AC, 200/220V AC
B: 86.5 (2 blocks), 106.5 (4 blocks)
Contact Arrangement Chart
37
ø24
Panel Thickness 1 to 6
ø29
Shape
Spring Return
from Right
L
R
Spring Return
from Left
L
R
Mounting
Position
Type
1
NO
Without Lamp
Full Voltage
ASLW29911➁
ASLW219911➁
ASLW229911➁
2
NC
LED
Transformer
ASLW2➂11D➁
ASLW21➂11D➁
ASLW22➂11D➁
Incandescent
Transformer
ASLW2➂11➁
ASLW21➂11➁
ASLW22➂11➁
11
(1NO-1NC)
20
(2NO)
22
R
1
NO
Without Lamp
Full Voltage
ASLW29920➁
ASLW219920➁
ASLW229920➁
2
NO
LED
Transformer
ASLW2➂20D➁
ASLW21➂20D➁
ASLW22➂20D➁
Incandescent
Transformer
ASLW2➂20➁
ASLW21➂20➁
ASLW22➂20➁
Without Lamp
Full Voltage
ASLW29922➁
ASLW219922➁
ASLW229922➁
LED
Transformer
ASLW2➂22D➁
ASLW21➂22D➁
ASLW22➂22D➁
Incandescent
Transformer
ASLW2➂22➁
ASLW21➂22➁
ASLW22➂22➁
1
2
3
4
(2NO-2NC)
L
NO
NC
NO
NC
• Color Code and Operating Voltage Code
LED Illuminated Type
➁ Lens/LED Color Code
Specify a lens/LED color code in
place of ➁ in the Type No.
Incandescent Illuminated Type
➂ Operating Voltage Code
➁ Lens Color Code
Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No.
➁ in the Type No.
16: Transformer (100/110V AC)
A: amber
156: Transformer (115V AC)
G: green
136: Transformer (120V AC)
R: red
26: Transformer (200/220V AC)
S: blue
236: Transformer (230V AC)
W: white
256: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
• Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36.
• LED illuminated transformer type contains an LED lamp (LSTD-6➁, rated voltage 6V AC/DC).
• Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
• Contact Block Mounting Position and Contact Arrangement Chart
4
2
Left
TOP
Right
L
3
1
1
2
3
4
R
NO
NC
NO
NC
Operator
Position
• For more contact arrangement chart, see pages 27 to 29.
25
TW_EP1070.book Page 26 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Selector Switches
Illuminated Selector Switches
45° 3-position
Contact
Block
Contact
Code
Mounting Type
Position
20
(2NO)
02
(2NC)
22
(2NO-2NC)
40
(4NO)
04
(4NC)
1
NO
2
NO
1
NC
2
NC
1
2
3
4
NO
NO
NC
NC
1
2
3
4
NO
NO
NO
NO
1
2
3
4
NC
NC
NC
NC
Operator
Position
L
C
Maintained
Spring Return
from Right
Spring Return
from left
C
C
C
Lamp
Input Type
R
R
L
Without Lamp
Full Voltage
LED
Transformer
Incandescent
Transformer
Without Lamp
Full Voltage
LED
Transformer
Incandescent
Transformer
Without Lamp
Full Voltage
LED
Transformer
Incandescent
Transformer
Without Lamp
Full Voltage
LED
Transformer
Incandescent
Transformer
Without Lamp
Full Voltage
LED
Transformer
Incandescent
Transformer
L
R
L
Spring Return
Two-way
C
R
L
R
ASLW39920
ASLW319920
ASLW329920
ASLW339920
ASLW3➂20D➁
ASLW31➂20D➁
ASLW32➂20D➁
ASLW33➂20D➁
ASLW3➂20➁
ASLW31➂20➁
ASLW32➂20➁
ASLW33➂20➁
ASLW39902
ASLW319902
ASLW329902
ASLW339902
ASLW3➂02D➁
ASLW31➂02D➁
ASLW32➂02D➁
ASLW33➂02D➁
ASLW3➂02➁
ASLW31➂02➁
ASLW32➂02➁
ASLW33➂02➁
ASLW39922
ASLW319922
ASLW329922
ASLW339922
ASLW3➂22D➁
ASLW31➂22D➁
ASLW32➂22D➁
ASLW33➂22D➁
ASLW3➂22➁
ASLW31➂22➁
ASLW32➂22➁
ASLW33➂22➁
ASLW39940
ASLW319940
ASLW329940
ASLW339940
ASLW3➂40D➁
ASLW31➂40D➁
ASLW32➂40D➁
ASLW33➂40D➁
ASLW3➂40➁
ASLW31➂40➁
ASLW32➂40➁
ASLW33➂40➁
ASLW39904
ASLW319904
ASLW329904
ASLW339904
ASLW3➂04D➁
ASLW31➂04D➁
ASLW32➂04D➁
ASLW33➂04D➁
ASLW3➂04➁
ASLW31➂04➁
ASLW32➂04➁
ASLW33➂04➁
• Color Code and Operating Voltage Code
LED Illuminated Type
Incandescent Illuminated Type
➂ Operating Voltage Code
➁ Lens Color Code
Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No.
➁ in the Type No.
16: Transformer (100/110V AC)
A: amber
156: Transformer (115V AC)
G: green
136: Transformer (120V AC)
R: red
26: Transformer (200/220V AC)
S: blue
236: Transformer (230V AC)
W: white
256: Transformer (240V AC)
386: Transformer (380V AC)
46: Transformer (400/440V AC)
486: Transformer (480V AC)
➁ Lens/LED Color Code
Specify a lens/LED color code in
place of ➁ in the Type No.
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
• Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36.
• LED illuminated transformer type contains an LED lamp (LSTD-6➁, rated voltage 6V AC/DC).
• Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC).
• Contact Block Mounting Position and Contact Arrangement Chart
4
Center
Left
2
L
3
1
26
Right
TOP
1
2
3
4
NO
NO
NC
NC
C
R
Operator
Position
• For more contact arrangement chart, see pages 27 to 29.
TW_EP1070.book Page 27 Wednesday, January 19, 2005 10:49 AM
TW Series Selector Switch Contact Arrangement Charts ø22
90° 2-position (Maintained / Spring Return)
Maintained
Positions
L
R
Operator Types
Spring
Return
from Right
Spring Return from Left
L
R
L
R
Knob, Lever, Key, Illuminated
Operator Positions
Contact
Code
Circuit Mounting
No.
Position
Type
L
10
(1NO)
01
(1NC)
11
(1NO-1NC)
20
(2NO)
02
(2NC)
—
—
—
103
—
—
—
109
22
(2NO-2NC)
110
111
117
31
(3NO-1NC)
40
(4NO)
107
—
118 ★
2R ★
168 ★
119 ★
169 ★
120 ★
170 ★
4R ★
121 ★
171 ★
1
2
1
2
1
2
1
2
1
2
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
1
2
1
2
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
NO
Dummy
NC
Dummy
NO
NC
NC
NO
NO
NO
NC
NC
NO
NC
NO
NC
NO
NC
NC
NO
NC
NO
NC
NO
NO
NO
NC
NC
NC
NO
NO
NC
NC
NO
NO
NO
NO
NO
NO
NO
NO
NC
NO
NC
NC
NO
NC
NO
NO
NC
NO
NC
NO
NC
NO
NC
NC
NO
NC
NO
NC
NO
NC
NO
R
L
R
• Contact Block Mounting Position and
Contact Arrangement Chart
4
3
TOP
2
1
Left
Right
L
1
2
3
4
R
NO
NC
NO
NC
Operator
Position
• On the contact arrangement marked with
★ in the table, the rated current (load
switching current) is reduced to a half of
the rated current of the contact block.
The rated insulation voltage and the rated
thermal current remain unchanged.
Type No. Development
• When circuit number is not required:
ASW 2 11
Contact Code (1NO-1NC)
2-position
• When circuit number is required:
ASW 2 11 - 103
Circuit No.
Contact Code (1NO-1NC)
2-position
27
TW_EP1070.book Page 28 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Selector Switch Contact Arrangement Charts
45° 3-position (Maintained / Spring Return)
Maintained
Positions
Spring Return Spring Return Spring Return
from Right
from Left
Two-way
C
C
Operator Types
C
C
R
L
R
L
L
R
L
R
Knob, Lever, Key, Illuminated
Operator Positions
Contact
Code
Circuit Mounting
No.
Position
Type
L
202
203
11
302
303
—
20
301
—
02
304
—
210
22
(2NO-2NC)
308
309
310
206
31
(3NO-1NC)
207
212
13
313
—
40
305
—
04
314
28
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
NO
NC
NC
NO
NO
NC
NC
NO
NO
NO
NO
NO
NC
NC
NC
NC
NO
NO
NC
NC
NC
NO
NC
NO
NO
NC
NO
NC
NO
NC
NC
NO
NC
NO
NC
NO
NO
NC
NO
NO
NC
NO
NO
NO
NO
NC
NC
NC
NC
NO
NC
NC
NO
NO
NO
NO
NO
NO
NO
NO
NC
NC
NC
NC
NC
NC
NC
NC
C
R
• Contact Block Mounting Position and
Contact Arrangement Chart
4
3
1
Center
Left
L
1
2
3
4
TOP
2
C
Right
R
NO
NO
NC
NC
Operator
Position
Type No. Development
• When circuit number is not required:
ASW 3 22
Contact Code (2NO-2NC)
3-position
• When circuit number is required:
ASW 3 22 - 210
Circuit No.
Contact Code (2NO-2NC)
3-position
TW_SS Page 29 Wednesday, January 19, 2005 1:55 PM
TW Series Selector Switch Contact Arrangement Charts ø22
45° 3-position (Maintained)
45° 4-position (Maintained)
Maintained
Maintained
C
Positions
L
2
Positions
R
3
1
4
Operator Types
Contact
Code
Circuit
No.
Mounting
Position
Knob, Lever, Key,
Illuminated
Operator Types
Operator Positions
Contact
Code
Type
3S ★
1361 ★
243 ★
233 ★
234 ★
4S ★
235 ★
237 ★
240 ★
1
2
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Operator Positions
Circuit
No.
Mounting
Position
Type
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
NO
NC
NC
1
L
2S ★
Knob, Lever
C
R
NO
NC
NO
NO
NC
3S ★
461 ★
405 ★
Dummy
NO
NC
NO
NO
NO
NC
NC
NC
NC
NO
NC
NO
NO
NO
NC
NO
NC
NC
NC
NO
407 ★
4S ★
409 ★
411 ★
2
3
4
Dummy
NC
NC
NC
NC
NC
NC
NC
NO
NO
NC
NC
NC
NO
NC
NC
NO
30° 5-position (Maintained)
Maintained
Positions
2
Operator Types
5
Knob, Lever
Contact
Code
Circuit
No.
Mounting
Position
Type
501 ★
1
2
3
4
NO
NC
NC
NO
Maintained
1
C
L
R
4S ★
Knob, Lever,
Illuminated
Operator Types
4
Operator Positions
45° 3-position (Maintained)
Positions
3
1
2
3
4
5
Operator Positions
Contact
Code
Circuit
No.
Mounting
Position
Type
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
NO
NO
NC
NC
NC
NO
NC
NC
NO
NC
NC
NO
NO
NC
NO
NC
NC
NC
NC
NC
L
1336 ★
1337 ★
4S★
1352 ★
1355 ★
1359 ★
C
4
R
2
TOP
Center
Left
L
3
1
1
2
3
4
NO
NC
NO
NO
C
Right
R
Operator
Position
• On the contact arrangement marked with ★ in the
table, the rated current (load switching current) is
reduced to a half of the rated current of the contact
block. The rated insulation voltage and the rated
thermal current remain unchanged.
29
TW_EP1070.book Page 30 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Accessories and Replacement Parts
Accessories
Terminal Cover
HW-VL2
HW-VL3
HW-VL4
HW-VL5
HW-VL6
APS-PVL
Use of terminal covers
increases
the depth by
the dimensions below.
Terminal
Cover
Control Unit
• Pilot light
APW
APQW
39.8H × 14.1W 37.8H × 26W 39.8H × 8.7W 39.1H × 15.5W 40H × 14.8W
Full Voltage
36H × 29.4W
X
+6mm
X
+3mm
X
+3mm
Transformer
DC-DC Converter
• Pushbutton 1 contact block
ABW
AOW
CB
Terminal Cover
AVW
ABQW
ABFW
AJW
2 contact blocks
AOQW
AOFW
CB
AXW
CB
ABGW
AYW
3 contact blocks
• Selector
switch
CB CB
ASW
CB
X
X
2 pieces
+3.5mm
X
2 pieces
4 contact blocks
CB CB
CB CB
• Illuminated Full Voltage, 1 or 3 contact blocks
pushbutton
ALW
CB
AOLW
FA
ALFW
AOLFW
ALQW
Full Voltage, 2 or 4 contact blocks
AOLQW
AVLW
CB
AYLW
CB
• Illuminated
selector
switch
ASLW
X
2 pieces
X
2 pieces
+3.5mm
X
For contact blocks
2 pieces
+3mm
Transformer
DC-DC Converter
CB
CB Tr
X
• Ordering Terminal Covers
Terminal covers are ordered separately.
When ordering terminal covers, specify the Type No. and required quantity.
30
X
For full
voltage
adapter
+3mm
TW_EP1070.book Page 31 Wednesday, January 19, 2005 10:49 AM
TW Series Accessories and Replacement Parts ø22
Nameplates
NWA, NWAQ, NWAS, NWAR, NWAL, NWAQL, and NWAV
Dimensions
(mm)
NWA
Legend
Blank
29
Type No.
NWA-∗
With Legend
NWAQ
Blank
29
NWAQ-∗
21
With Legend
14.5
Package
Quantity
NWA-0
1
NWA-0PN10
10
NWA-∗
1
NWA-∗PN10
10
NWAQ-0
1
NWAQ-0PN10
10
NWAQ-∗
1
NWAQ-∗PN10
10
NWAS-0
1
Description
Black
NWAQ-0
Aluminium
0.8 mm thick
OFF
Ordering Type
No.
NWA-0
Aluminium
0.8 mm thick
OFF
20
Material
White letters on
black background
Black
White letters on
black background
NWAS
45
45
Blank
Aluminium
0.8 mm thick
NWAS-0
RGENC
ME
Blank
ø70
STOP
NWAS-0PN10
10
NWAR-0
1
NWAR-0PN10
10
NWAR-27
1
NWAR-27PN10
10
NWAL-0
1
NWAR-0
Aluminium
0.8 mm thick
Y
E
NWAR
Black
EMERGENCY
STOP
Yellow
NWAR-27
Black letters on
yellow background
NWAL
29
25
Blank
Aluminium
0.8 mm thick
NWAL-0
Black
NWAL-0PN10
10
NWAQL-0
1
NWAQL
29
NWAQL-0
Black
NWAQL-0PN10
10
HWAV-0
HWAV-0
1
Yellow
HWAV-27
HWAV-27
1
Black letters on
yellow background
14.5
25
Blank
Aluminium
0.8 mm thick
HWAV
Blank
ø60
Plastic
EMERGENCY
STOP
• Specify a legend code in place of ∗ in the Ordering Type No.
Legends
Code
0
1
2
3
4
31
35
53
Legend
(blank)
ON
OFF
START
STOP
OFF-ON
HAND-AUTO
HAND-OFF-AUTO
31
TW_EP1070.book Page 32 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Accessories and Replacement Parts
Accessories
Material
Type No.
Ordering
Type No.
Package
Quantity
Dimensions
OR-14
OR-14
1
90
ø34
Rubber
ø31
• Used to tighten the locking ring when installing
the TW control unit onto a panel.
Locking Ring Wrench
ø46
Shape
16
For ø22mm units
(close mounting)
For ø22/ø25mm units
OR-55
OR-55
1
ø14
Rubber
ø11.6
• Used to install and remove LED/incandescent
lamps.
Lamp Holder Tool
59
• Used to remove contact blocks, transformers,
lenses and adapters. Can also be used to
determine panel thickness adjustment.
23
Contact Block Removal Tool
TW-KC1
TW-KC1
1
130
39
ø19
Metal/Rubber
• Used to tighten the locking nuts inside of the
square bezel.This tool can be inserted into the
OR-14 locking ring wrench.
Nut Locking Wrench
20
TW-KQ2
TW-KQ2
1
25.7
22.5
Metal
80
• Used to prevent the operator from rotating.
Generally used when using no nameplates on
selector switches.
Anti-rotation Ring
OGL-31
OGL-31PN10
10
10.2
Metal
ø22
ø27.4
0.8
• Used to plug unused ø22.2mm mounting holes.
Rubber Mounting Hole Plug
ø29
5
LW9Z-BM
LW9Z-BM
1
ø25.8
12
Gasket
Plastic
HW-VL1
HW-VL1PN10
10
• Used to prevent
contact between
adjacent lead wires
when units are
mounted closely.
Barriers should be
always used in
close mounting.
45
Locking Ring
Barrier
20
32
3
• Used to plug unused ø22.2mm mounting holes.
• Tightening torque: 1.2 N·m
• Degree of protection: IP66 (without the 3.2mm
recess in the mounting hole)
Metallic Mounting Hole Plug
Diecast Metal
(locking ring:
plastic)
ø25
3.5
OB-31PN05
3.5
Rubber (black) OB-31
1.5
TW_Accessory Page 33 Wednesday, January 19, 2005 1:40 PM
TW Series Accessories and Replacement Parts ø22
Accessories
OCW-99
Ordering
Type No.
OCW-99
Package
Quantity
1
Description
• Oiltight rubber boot used for pushbuttons and
selector switches.
• Temperature range: –5 to +60°C
• Black
OCW-99
Rubber
(nitryl)
OCW-299
OCW-299
1
50
For 2 layers of
contact blocks
(4 contact
blocks)
OCW-299
OC-32
OC-32
1
Rubber
(EPDM)
For extended
pushbuttons
(ABW2/AOW2)
Button Cover
For flush
pushbuttons
(ABW1/AOW1)
OCW-10➀
OCW-10➀
1
Rubber
(nitryl)
18 (OC-31)
22 (OC-32)
• Metallic bezels covered with rubber boot to
enhance waterproof and oiltight characteristics.
• Button is installed in the cover. Remove the button from the pushbutton before using the button
cover.
• ➀: B (black), G (green), R (red), Y (yellow)
9
M22 P1.0
ø32
For extended
pushbuttons
(ABW2/AOW2)
OCW-11➀
OCW-11➀
9
M22 P1.0
1
ø26
1
ø32.6
OC-31
ø32
OC-31
• Used to cover and protect pushbuttons
where units are subject to water splash.
Not suitable for outdoor use or where the
units are subject to oil
splash.
ø31
For flush
pushbuttons
(ABW1/AOW1)
65.5
14
38
Pushbutton
Clear Boot
45.5
14
38
Button
installed
18.5
21
ø31
For 1 layer of
contact blocks
(2 contact
blocks)
Type No.
2.2
Contact Rubber
Boot
Material
48
Shape
Button
installed
Extended
Flush
• Used to protect momentary and maintained
pushbuttons, illuminated pushbuttons, knobs
selector switches, and key selector switches.
Padlock Cover
82.5
1
93
70
30
HW9Z-KL1
6.5
HW9Z-KL1
R6
Polyarylate
(gasket: nitryl
rubber)
Panel Thickness
0.8 to 3.2
24 (inside)
ALW4L-➁
2
ALW4L-➁
2.
ø40mm Lens
ø2
0 4)
ø5 44.
:ø
(ID
Key hole ø8
• Applicable unit:
ALW3, AOLW3
ALW4LD-➁
ALW4LD-➁
1
ALW4BL-➁
ALW4BL-➁
1
Waterproof Rubber
Gasket 0.5t
➁: G (green), R (red)
1
Non-marking
Type
29.5
30
S (blue)
➁: A (amber),
W (white)
Plastic
Marking Type
ALW4BLD-➁ ALW4BLD-➁
1
• Applicable unit:
ALW3B, AOLW3B
• Marking plate is
included
➁: G (green), R (red),
S (blue), W (white)
➁: A (amber)
Note: Specify a button color code or lens color code in place of ➀ or ➁ in the Ordering Type No.
33
TW_EP1070.book Page 34 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Accessories and Replacement Parts
Accessories
AW-RP1BPN05
5
➁Extended
AW-FP1B
AW-FP1B
1
AW-FP2B
AW-FP2B
1
➂Extended
(for illuminated
Plastic
pushbuttons)
➃Square round
(for round
pushbuttons)
➅
➂
AW-Q1B
AW-Q1B
1
AW-R1
AW-R1PN05
5
Aluminium color
(standard)
AW-R1B
AW-R1B
1
Black
AW-F1
AW-F1
1
AW-F2
AW-F2
1
AW-G4
AW-G4
1
➀Knob
ASWHHY-➁
ASWHHY-➁PN02
2
➁Lever
ASWHHL-➁
ASWHHL-➁PN02
2
➂Round
ASWHHM-B
ASWHHM-BPN02
2
Black only
➂Extended (for
illuminated
pushbuttons)
Aluminium
➃Mushroom
Selector Operator
➁
➀
➂
➃Color Insert
➄
➃
➂
1
➁Extended
Plastic
➄Illuminated
selector
ø29
ø29
AW-H1B
➀Flush
➁
Black
AW-H1B
➄Square
Aluminium Bezel
➀
➁
➀
19.8
AW-RP1B
13
➀Flush
Dimensions
➃
13
➄
➃
Package
Quantity
ø29
30
➄
13
➂
Ordering
Type No.
Type No.
19.8
Plastic Bezel
➁
➀
Material
30
Aluminium color
(standard)
➅
23
23
Shape
ø46
ø46
Specify a color code in place of ➁.
B (black), G (green), R (red)
TW-HC1➁
TW-HC1➁PN05
5
Specify a color code in place of ➁.
B (black), G (green), R (red), S (blue),
W (white), Y (yellow)
ASLWDDY-➁
ASLWDDY-➁
1
Specify a color code in place of ➁.
A (amber), W (white), Y (yellow)
ASLWLDY-➁
ASLWLDY-➁
1
Specify a color code in place of ➁.
G (green), R (red), S (blue)
• Used to protect flush pushbuttons from
inadvertent operation.
Metal Protector
Metal
OLW-C
OLW-C
Mounting Centers
50 min.
18.6
1
ø22.5
R4
2.5
15
1.6t
Maintenance Parts
Shape
Contact Block
Specification
Type No.
Ordering
Type No.
Package
Quantity
Push Rod
1NO contact
HW-C10
HW-C10
1
Blue
Green
1NC contact
HW-C01
HW-C01
1
Purple red
Red
EM contact
(early make)
LB contact
(late break)
HW-C10R HW-C10R
1
Blue
Black
HW-C01R HW-C01R
1
Purple red
White
Dummy Block
TW-DB
TW-DBPN10
10
Full Voltage Adapter
(for 2 or 4 contact blocks)
TW-DA1B TW-DA1BPN02
2
HW-DA1B HW-DA1BPN02
2
Full Voltage Adapter
(for 1 or 3 contact blocks)
34
Color
Housing
• Used for non-illuminated units with
1NO or 1NC contact blocks.
• Black
• Adapter with M3.5 screws used for
illuminated pushbutton or illuminated
selector switch. Snaps on to the back
of the contact block.
• Used with 2 or 4 contact blocks.
• Black
• Adapter with M3.5 screws used for
illuminated pushbuttons or illuminated selector switch.
• Used with 1 or 3 contact blocks.
• Black
TW_EP1070.book Page 35 Wednesday, January 19, 2005 10:49 AM
TW Series Accessories and Replacement Parts ø22
Maintenance Parts
Shape
Lens (for pilot lights)
Material
AS
Round flush
Round extended
Square flush
Lens (for illuminated
pushbuttons)
Round extended
Square extended
ø29mm mushroom
APQW11L-➁
AS,
Marking type
APQW11LD-➁
ALW2L-➁
AS
ALW2LD-➁
ALW21L-➁
AS,
Marking type
ALW21LD-➁
AS
APW11L-➁PN05
5
APW11LD-➁PN05
APW2L-➁PN05
APW2LD-➁PN05
5
5
5
APQW11L-➁PN05
5
APQW11LD-➁PN05
ALW2L-➁PN05
ALW2LD-➁PN05
5
5
5
ALW21L-➁PN05
5
ALW21LD-➁PN05
5
ALQW21L-➁PN05
5
ALQW21LD-➁ ALQW21LD-➁PN05
ALW3L-➁
ALW3L-➁PN02
ALW3LD-➁
ALW3LD-➁PN02
5
2
2
ALW31L-➁PN02
2
2
2
AVLW31L-RPN02
2
AS
AVLW4L-R
AVLW4L-RPN02
2
Round flush
ABW1B-➀
ABW1B-➀PN05
5
Round extended
ABW2B-➀
ABW2B-➀PN05
5
Square flush
ABQW1B-➀
ABQW1B-➀PN05
5
Square extended
ABQW2B-➀
ABQW2B-➀PN05
5
ø29mm mushroom
ABW3B-➀
ABW3B-➀PN02
2
ABW4B-➀
ABW4B-➀PN02
2
ø40mm mushroom
Marking Plate
(for illuminated
pushbuttons)
APW1L-➁PN05
APW1LD-➁PN05
Package
Color Code
Quantity
G (green), R (red), S (blue)
5
A (amber), W (white), Y (yellow)
5
ALW31LD-➁PN02
AVLW3L-RPN02
ø40mm mushroom
Marking Plate
(for pilot lights)
ALQW21L-➁
Ordering Type No.
ALW31L-➁
AS,
Marking type
ALW31LD-➁
AS
AVLW3L-R
AS,
Marking type AVLW31L-R
ø29mm mushroom
Button
APW1L-➁
APW1LD-➁
APW11L-➁
AS,
Marking type
APW11LD-➁
APW2L-➁
AS
APW2LD-➁
AS
Lens (for pushlock
turn reset)
Type No.
Polyacetal
C (clear), G (green), R (red),
S (blue)
A (amber), Y (yellow)
G (green), R (red), S (blue)
A (amber), W (white), Y (yellow)
C (clear), G (green), R (red),
S (blue)
A (amber), Y (yellow)
G (green), R (red), S (blue)
A (amber), W (white), Y (yellow)
C (clear), G (green), R (red),
S (blue)
A (amber), Y (yellow)
C (clear), G (green), R (red),
S (blue)
A (amber), Y (yellow)
G (green), R (red), S (blue)
A (amber), W (white), Y (yellow)
C (clear), G (green), R (red),
S (blue)
A (amber), Y (yellow)
B (black)
G (green)
R (red)
S (blue)
W (white)
Y (yellow)
ø29mm pushlock turn
reset
ø40mm pushlock turn
reset
AVW3B-➀
AVW3B-➀PN02
2
R (red), Y (yellow)
AVW4B-➀
AVW4B-➀PN02
2
R (red), Y (yellow)
ø40mm push pull
AYW4B-➀
AYW4B-➀PN02
2
B (black), G (green), R (red),
S (blue), W (white), Y (yellow)
Round flush
APW2B
APW2BPN05
5
Square flush
APQW1B
APQW1BPN05
5
ALW2B
ALW2BPN05
5
Square extended
ALQW2B
ALQW2BPN05
5
ø29/40mm mushroom
ALW3B
ALW3BPN05
5
For APQW
APW00LN
APW00LNPN05
5
APW00L
APW00LPN05
5
Round extended
Acrylic
• White
Waterproof Lens
Acrylic
For ALQW
Note: Specify a button color code or lens color code in place of ➀ or ➁ in the Ordering Type No.
Use a clear lens for white or pure white illumination.
35
TW_EP1070.book Page 36 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Accessories and Replacement Parts
Maintenance Parts
Shape
Material
Type No.
Ordering Type No.
Package Quantity
Metal
TW-SK-0
TW-SK-0PN02
2
Spare Key
For Key Selector Switch
For Pushlock Key Reset
LED Lamps (LSTD Type)
Current Draw
Operating Voltage
AC
Ordering
Type No.
Type No.
DC
6V AC/DC ±5%
17 mA (A, R, W, Y) 14 mA (A, R, W, Y)
8 mA (G, PW, S)
5.5 mA (G, PW, S)
LSTD-6➁
LSTD-6➁
LSTD-1➁
LSTD-1➁
10 mA
LSTD-1➁PN10
24V AC/DC ±10%
LSTD-2➁
11 mA
Incandescent Lamps (LS Type)
Lamp Ratings
Type No.
1W (6.3V)
LS-6
1W (18V)
LS-8
Package Quantity
12V AC/DC
1
18V AC/DC
1W (24V)
LS-2
1W (30V)
LS-3
24V AC/DC
Transformer
Shape
Transformer Unit
Primary Voltage
Secondary Voltage
100/110V AC
Type No.
TW-T16B
120V AC
TW-T126B
5.5V
36
Specify a color code
in place of ➁ in the
Ordering Type No.
1
200/220V AC
TW-T26B
240V AC
TW-T246B
Base
10
A: amber
G: green
PW: pure white
R: red
S: blue
W: white
Y: yellow
1
BA9S/13
10
1
LSTD-2➁
10 mA
LSTD-2➁PN10
Rated Operating Voltage
6V AC/DC
Package
Quantity
LSTD-6➁PN10
12V AC/DC ±10%
11 mA
Illumination
Color Code
10
TW_Instructions Page 37 Wednesday, January 19, 2005 2:02 PM
TW Series Instructions ø22
Safety Precautions
• Turn off the power to the TW series control units before
starting installation, removal, wiring, maintenance, and
inspection of the products. Failure to turn power off may
cause electrical shocks or fire hazard.
• To avoid a burn on your hand, use the lamp holder tool
when replacing lamps.
• For wiring, use wires of a proper size to meet the voltage
and current requirements. Tighten the M3.5 terminal
screws to a tightening torque of 1.0 to 1.3 N·m. Failure to
tighten terminal screws may cause overheat and fire.
• Use HW-C type contact blocks for the TW series. Do not
replace with or add conventional TW series contact blocks.
Using a different type of contact block may lead to malfunction.
HW-C Type
Contact Block
TW Type
Contact Block
Rectangular
Holes
Instructions
Panel Mounting
Panel thickness adjustment ring is used for the TW series. To attach the TW series to the panel, follow the procedures below.
➀Panel Thickness Adjustment
➁Attaching the Unit to the Panel
with the Bezel
➂Attaching the Button, Lens, and
Knob
Bezel
Mounting order
Panel thickness adjustment ring
Panel
Lens
Panel
Installation method
Type
Attach the unit with the panel
thickness scale facing up.
Remarks
Contact block removal
tool
Panel thickness adjustment
z
Adjusting Panel Thickness
The panel thickness ring provides adjustment from 1 to 6
mm in 1-mm increments. Set the panel thickness to line A.
Rotate the ring until the desired thickness indication around
the periphery is aligned with line A, as shown below.
Scale on Adjustment (in 0.1 mm)
0.2
0.3
0.4
For installing or removing waterproof lenses after the bezel is
attached.
1.6 mm
0.5
0.6
0.7
0.8
0.9
0
2.3 mm
2
3
4
5
1 mm
Panel Thickness
Adjustment Ring
Panel Thickness Scale
(in 1 mm on the operator)
6
1 mm
A
Ex. Panel thickness 2 mm
Contact Block
Removal Tool
3.5 mm
1
2
4
6
For installing or removing round
lenses.
• Using the Contact Block Removal Tool to Adjust Panel
Thickness
Panel thickness can easily be adjusted to the values shown
below by inserting the contact block removal tool between
the adjustment ring and base.
0.1 mm
3
5
Screw in
For tightening or removing square
bezels.
Tools Nut locking wrench
0.1
Press in
29mm/40mm mushroom
button/lens, Dome lens
For tightening or removing round
bezels.
Locking ring wrench
0
Method
Flush/Extended pushbuttons,
Square lens, Selector operator
3
5
4
6
2 mm
3.2 mm
Ex. Panel thickness 2.6 mm
Note: When a nameplate or an anti-rotation ring is used, add
0.8mm to the panel thickness.
Total thickness
= Panel thickness + 0.8mm (nameplate or anti-rotation ring thickness)
37
TW_EP1070.book Page 38 Wednesday, January 19, 2005 10:49 AM
ø22 TW Series Instructions
Instructions
Mounting into Panel Cut-out with Bezel
• Insertion into Panel Cut-out
Insert the base into the panel
cut-out making sure that the
panel thickness scale is facing
up.
Panel thickness
adjustment ring
• Round Bezel
All round bezels are screw-in
type. Be sure to use the locking
ring wrench to tighten the
bezel.
Locking Ring Wrench
OR-14 (optional)
Side B
• Square Bezel
1. Insert the base plate from
the front.
Base Plate
2. Insert the lock nut. For
easy installation, use the
nut locking wrench.
Lock Nut
Remove
Tighten
Nut Locking Wrench
TW-KQ2 (optional)
3. Mount the square bezel.
The bezel will snap onto
the base plate.
Side A
Square Bezel
Use side B when
mounting the units
closely.
• Recommended tightening torque is 2.0 N·m.
Square Lens
Press in
[Square Illuminated Pushbutton]
Flat screwdriver
(5mm wide at
maximum)
2. Removing the Marking
Plate
• Pilot Light
Insert the screwdriver into the
recess of the lens.
Marking Plate
Small flat screwdriver
Lens Retainer
Waterproof Lens
• Illuminated Pushbuttons
Insert the screwdriver into the
hook and lightly push out the
lens.
[Round Marking Type]
Lens
Marking
Plate
Press in
38
Flat screwdriver
(5mm wide at
maximum)
3. Other Notes
The square lens of the illuminated pushbutton cannot be
used without waterproof lens.
Always use the waterproof
lens.
Be sure to use the marking
plate even when it is not
engraved.
5
Square (Illuminated
Pushbutton)
1.0
4.4
ø
19
9
0.
13
2.6
Insert
Square Lens
Marking Plate
ø
14
Square (Pilot Light)
21
1.
[Square Pilot Lens]
1. Removing the Square Lens
Insert the screwdriver into the
recess of the lens and lightly
push out the lens.
Mushroom
21
Round
1.2
• Lens Structure and Marking Plate
All square lens units are marking types. To engrave on the
marking plate, remove the marking plate from the lens.
• Marking Plate Engraving Area
22
Installing Buttons, Lenses, and Operators
Note: The depth of the engraving must be within 0.5 mm.
• Installing Round Lens and Waterproof Lens
When installing or removing round lens of pilot lights and
illuminated pushbuttons and waterproof lens of square pilot
lights and illuminated pushbuttons, press the rubber part of
the contact block removal tool onto the lens or waterproof
lens for secure tightening and easy removal.
TW_EP1070.book Page 39 Wednesday, January 19, 2005 10:49 AM
TW Series Instructions ø22
Instructions
• Installation of Selector Operators
1. The shaft of each selector or illuminated selector switch
has a recess to identify in which direction to install the
operator. Align the operator with the recess and press in
the operator.
2. Press color insert (non-illuminated type) into the operator. The color insert retains the operator.
• Removing the Operator
Recess
Flat
screwdriver
Color insert
Recess
1.Removing the Color
Insert
Insert a flat screwdriver into
the recess of the color
insert. Turn the screwdriver
to push out the insert from
the operator
Press in
2.Removing the Operator
(Non-illuminated)
Push the operator sideways
as shown in the left photo to
remove the operator.
Press in
Illuminated
Selector Switch
Selector Switch
(non-illuminated)
2-Position, 90º 3-Position, 45º 4-Position, 45º 5-Position, 30º
1
1 2 3
1 0 2
2
1
2 3 4
5
4
Recess
Flat
screwdriver
3.Removing the Operator
(Illuminated)
Insert a flat screwdriver into
the recess of the operator
and turn the screwdriver to
remove the operator.
[Example]
1
0
1
2
1
0
0
2
2
Standard Position
The non-illuminated operators can be installed in positions
other than the standard position as shown above.
Removing Contact Blocks, Transformers
and Full Voltage Adapters
Insert the end of the contact block removal tool into the
snap-fit latch of the contact block (or transformer, full-voltage adapter) and pull the tool as shown below.
Pull
Collective Mounting
When mounting the units closely in a horizontal row on 30mm centers, use optional barriers to prevent interconnection
between adjoining terminals. The barriers can be attached
simply by pressing them onto the sides of contact blocks.
30
30
Barrier (HW-VL1)
Tightening Torque for Terminal Screws
Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3
N·m
39
TW_Instructions Page 40 Tuesday, February 22, 2005 10:21 AM
ø22 TW Series Instructions
Installation of LED Illuminated Units
1. Note the polarity for wiring when connecting to DC-DC
converter unit.
Terminal No.
X1
X2
Polarity
Positive
Negative
2. Transformer type units are recommended for use in areas
subjected to noise.
3. Notes for Pure White LED Lamps
• Do not use the pure white LED outdoors, otherwise it will
lead to the degradation of brightness and color. Do not
remove or apply shock to the cap on the pure white LED
lamp, otherwise it may break or damage the cap.
• For the pure white LED, use a white lens. The illumination
color will be dull if a different color is used.
Notes on LED Illuminated Units
LED lamps consist of semiconductors. If the applied voltage
exceeds the rated voltage, LED elements may deteriorate
due to overheat, resulting in significant decrease in luminance, hue change, or failure of lighting. Also, if an extraneous noise, transient voltage, or transient current is applied to
the circuit, similar effects may occur. When using LED
lamps, observe the following instructions.
• Rated Voltage
The LED lamps are rated at 6V, 12V, or 24V AC/DC, and can
be used within ±10% the rated voltage of either AC or DC.
• DC Power
1. Switching power supply
Regulated voltage from switching power supply is best
suited. Make sure to use within the rated voltage of the
LED lamp.
2. Rechargeable battery
Note that the battery voltage may exceed the rated voltage of the LED lamp while the battery is being charged
and immediately after the charging is complete. Be sure
to use the LED lamp on a voltage of ±10% the rated voltage.
3. Full-wave rectification
Since the LED lamp is AC/DC compatible, a diode bridge
for rectification is not necessary. If the LED lamp is used
on a full-wave rectification current through a diode bridge,
the rectifier diodes will reduce the voltage, resulting in
lower luminance.
4. Single-phase half-wave rectification
This is not suitable for the power source of LED lamps.
Use constant-voltage DC power.
• Noise
LED elements deteriorate due to extraneous noise, resulting
in significant decrease in luminance, hue change, or failure
of lighting. When such effects are anticipated, take a protection measure shown below, such as RC elements or a surge
absorber.
[Protection Example 1] For AC circuit
LED with
transformer
C
C
LED with
transformer LED
Relay Ry
coil or
solenoid
R
LED
R
(Reference values) R: 120Ω
C: 0.1µF
[Protection Example 2] For DC circuit
+
(Reference values of the diode)
Forward current: More than the Ry coil current
Reverse withstand voltage: Ry coil current × 10
Relay Ry
coil or
solenoid
LED
Diode
–
• Countermeasures against Dim Lighting
1. Leakage currents through the transistors or a contact
protection circuit may cause the LED lamp to illuminate
dimly even when the output is off.
2. When the LED lamp is illuminated by a transistor output,
take the following measure.
[Circuit Example]
Connect shunt resistor R in parallel with the LED lamp.
R
LED
Io
Io: Leakage current when the output is off
R: Shunt resistor
Specifications and other descriptions in this catalog are subject to change without notice.
7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan
Tel: +81-6-6398-2571, Fax: +81-6-6392-9731
www.idec.com
IDEC CORPORATION (USA)
IDEC IZUMI ASIA PTE. LTD.
1175 Elko Drive, Sunnyvale, CA 94089-2209, USA
Tel: +1-408-747-0550, Toll Free: (800) 262-IDEC, Fax: +1-408-744-9055
E-mail: [email protected], www.idec.com
No. 31, Tannery Lane #05-01, Dragon Land Building, Singapore 347788
Tel: +65-6746-1155, Fax: +65-6844-5995
E-mail: [email protected]
IDEC CANADA LIMITED
IDEC IZUMI (H.K.) CO., LTD.
Unit 22-151, Brunel Road Mississauga, Ontario, L4Z 1X3, Canada
Tel: +1-905-890-8561, Toll Free: (888) 317-4332, Fax: +1-905-890-8562
Unit 1505-07, DCH Commercial Centre No. 25, Westlands Road,
Quarry Bay, Hong Kong
Tel: +852-2803-8989, Fax: +852-2565-0171
E-mail: [email protected]
IDEC ELECTRONICS LIMITED
Unit 2, Beechwood, Chineham Business Park, Basingstoke, Hampshire
RG24 8WA, UK
Tel: +44-1256-321000, Fax: +44-1256-327755
E-mail: [email protected]
IDEC ELEKTROTECHNIK GmbH
Wendenstrasse 331, D-20537 Hamburg, Germany
Tel: +49-40-25 30 54 10, Fax: +49-40-25 30 54 24
E-mail: [email protected], www.idec.de
IDEC AUSTRALIA PTY. LTD.
2/3 Macro Court, Rowville, Victoria 3178, Australia
Toll Free: 1-800-68-4332, Fax: +61-3-9763-3255
E-mail: [email protected]
IDEC IZUMI (Shanghai) Co., Ltd.
Room E, 15F, Majesty Building, No. 138 Pudong Avenue,
Shanghai 200120, P.R.C.
Tel: +86-21-5887-9181, Fax: +86-21-5887-8930
E-mail: [email protected]
IDEC TAIWAN CORPORATION
8F, No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, Taipei County, Taiwan
Tel: +886-2-2698-3929, Fax: +886-2-2698-3931
E-mail: [email protected]
Cat. No. EP1070-0 JANUARY 2005 13DNP PRINTED IN JAPAN

Similar documents