Assembly and Modular Table Power System Installation

Transcription

Assembly and Modular Table Power System Installation
Assembly and Modular Table Power System Installation Instructions
for Train® Tables
Topic
Table of Contents
Page
Attach Stretcher to Legs
2
Attach Base To Table Top
3
Attach Modesty Panel to Assembly
4
Modular Table Power System Installation
General Safety Warnings
Ganging Hardware
Electrical Circuits
5
5
5
5
Modular Table Power Assemblies
6
Installing Modular Cable for
End-to-End Applications
7
Cable Routing Restrictions
8
Rectangular Tables
Note: Refer to assembly direction
# 939600192 for assembly of
base power infeed.
90 Corner Top
Modesty Panel
If you have a problem, question, or request, call
your local dealer, or Coalesse at 1.800.627.6770
Or visit our website: www.coalesse.com
© 2015 Coalesse
San Francisco, California U.S.A.
Printed in U.S.A.
Page 1 of 8
939505524 Rev C
STRETCHER
SHIPPED COMPONENTS:
(1) Table top
(2) Legs
(1) Stretcher
Attach Stretcher To Legs
HARDWARE:
Stretcher Hardware:
(4) #730574 Allen Head Screws, 3/8-16 x 1”
(2) #811679 Stretcher Joint Backer Plate
(4) #732353 Lock Washers
2. Attach the stretcher to each leg
casting.
The Backer Plate (#811679) is
installed on the outside of the
casting as shown.
The stretcher is attached to each
leg casting with (2) Allen Head screws
(#730574) and two lock washers.
Table Top Mounting Hardware:
(8) #A730461 Flathead Phillips wood
screws, #10x7/8”, black
1. Unwrap the stretcher from package.
BACKER PLATE
LOCK WASHERS
ALLEN HEAD SCREWS
TOOLS REQUIRED:
Electric Drill with 6” extension and:
• #2 Phillips bit
• T-27 Torx bit
• 7/32” Allen wrench bit
(NOTE: Hand tools may be substituted for
the electric drill bits if necessary)
WARNING: Protect top surface from
scratches while attaching base feet.
Page 2 of 8
939505524 Rev C
Attach Base To Table Top
1. Carefully place table top upside
down onto carpet or other soft, clean
surface. Lower base assembly into
place onto the table top. The leg
attachment brackets should fit
into the pockets routed into the
underside of the table top.
1
2
2. Attach the leg attachment
brackets to the table top using
(3) #A730461 screws in each
bracket. The 4th hole in the leg
attachment brackets will be
covered by the leg castings while
the table is upside down.
1
Install (3) screws
through each
bracket at this time.
ROUT
3. Carefully set the table right side
up, then drop top into vertical position.
This will give access to install the
4th screw in each bracket.
TIP: Place a shim under carpet
to allow a finger hold when
assembled unit is ready to upright.
SWING ARM
3
To drop table top into vertical position:
A) disengage plastic sliders (both sides)
B) rotate each swing arm toward the base
C) rotate top into vertical position
Page 3 of 8
939505524 Rev C
SHIPPED COMPONENTS
(1) modesty panel
(1) hardware package
MODESTY PANEL
HARDWARE PACKAGE
(4) (73053705) torx head screws, 1/4-20 x 1/2”
(1) (811772R) right-hand bracket, R
(1) (811772L) left-hand bracket, L
(1) latchlock tape on each bracket
TOOLS REQUIRED
(1) electric drill or rachet with T-27 torx bit
R
Attach Modesty Panel To Assembly
LATCHLOCK
TAPE
Note: To attach the modesty panel,
Train table top must be flipped up.
1.
2.
3.
4.
Brackets are identified with “L”
or “R”. Attach the left-hand
bracket, “L”, LOOSELY to the
leg on the user’s left with (2)
torx head screws. Attach the
right-hand bracket, “R”,
LOOSELY to the leg on the
user’s right with (2) torx head screws.
Attach modesty panel to table by slipping
the clips over the stretcher.
Align top of brackets with top of modesty panel.
Also, adjust brackets on each side for the latchlock
tape surface to fully contact the modesty panel.
With upper modesty panel door open, peel off the
protective backing of the latchlock tape to expose
the adhesive. Close the modesty panel door and
firmly press the door, adhering the latchlock tape
on each bracket to the door.
DO NOT OPEN THE MODESTY PANEL DOOR FOR 24 HOURS.
For full cure the door should not be opened for 24 hours.
1
Attach bracket,
facing outward,
to inside of leg.
BRACKET
RH
BRACKET
FLIPPED
TOP
LH
BRACKET
CLIPS
STRETCHER
Page 4 of 8
939505524 Rev C
Modular Table Power System Installation
WARNING
Risk of Fire or Electric Shock
12" MAX.
1. For use in indoor, dry locations only.
2. Read and install in accordance with all assembly directions.
3. Only connect to products labeled "Modular Table Power System" by Steelcase.
4. Do not modify or strain cables. If damaged, remove from service immediately.
5. Disconnect modular electrical connections before servicing or reconfiguring tables.
6. Tables must be held together with ganging hardware as described in this document,
and NOT held together solely by electrical components.
7. Cable clamps must be no more than 12" from modular cable end connector or receptacle.
Ganging Hardware
SPIKE
CABLE
LENGTH
12" MAX.
SLOT
Electrical components MUST be
accompanied by ganging hardware.
Table-to-Table: Tables must be
held together with table connection
hardware, shown in illustration at right,
NOT by electrical components.
A coupling device is built into
every Train Table to enable tables
to gang together end-to-end
without tools or separate parts.
Electrical Circuits
The modular table power kit is a 20 Amp, 4-wire, 2-circuit system. The 20 Amp plug infeed
allows up to 13 circuit-1 duplex receptacles. The hardwire infeed allows up to 13 duplex
receptacles per circuit for a total of 26. The duplex receptacle(s) in the table power kit and
every two simplex receptacles from the desktop module count against the 13 duplex
receptacles allowed for each circuit. Receptacle faces on the Modular Table Power Kits are
marked I, for circuit 1 and II, for circuit 2.
WARNING
Neutral
Ground
Hot 2
Hot 1
White, 12 GA
Green or no coating, 12 GA
Red, 12 GA
Black, 12 GA
Risk of Fire or Electric Shock
Note: All electrical installations must be reviewed with the local authority for
compliance with local code, and must be performed by a qualified person in
accordance with codes and regulations applicable at the installation site.
Circuit 1
Circuit 2
Page 5 of 8
939505524 Rev C
Modular Table Power Assemblies
Single Receptacle
Double Receptacle
SHIPPED COMPONENTS:
- 1 cable assembly
- 1 hardware kit
SHIPPED COMPONENTS:
- 1 cable assembly
- 1 hardware kit
HARDWARE:
- 1 receptacle bracket
- 4 conduit clamps
- 2 conduit snap-clips
- 6 #10 phillips head screws - black
- 2 #8 phillips head screws - zinc
HARDWARE:
- 2 receptacle brackets
- 5 conduit clamps
- 2 conduit snap-clips
- 9 #10 phillips head screws - black
- 2 #8 phillips head screws - zinc
2
TOOLS REQUIRED:
#2 phillips head driver
TOOLS REQUIRED:
#2 phillips head driver
Table Width
Table Depth
24"
30"
Cable attachment hole
locations for single
receptacle cable.
48"
60"
72"
Cable Assembly Length
60"
72"
84"
54"
66"
78"
Installing Modular Cable for End-to-End Applications
Cable attachment hole
locations for double
receptacle cable.
2
1. Carefully place table top upside down
onto rug or other soft, clean surface.
2. Single receptacle
Identify the conduit path by locating (8) cable attachment holes:
(2) for receptacle bracket, (4) for conduit clamps and
(2) for conduit snap-clips.
Double receptacle
Identify the conduit path by locating (11) cable attachment holes:
(4) for receptacle brackets (5) for conduit clamps and (2) for conduit snap-clips.
If holes for double-receptacle brackets are not provided, use bracket as a template
to mark hole locations near single-receptacle holes. Drill holes .157" dia x .50" deep.
NOTE: Conduit clamps may be relocated for better cable fit.
Drill clamp holes .157" dia x .50" deep.
Page 6 of 8
939505524 Rev C
Installing Modular Cable for End-to-End Applications (continued)
3. Fasten receptacle bracket(s).
CONDUIT CLAMP
4. Fasten conduit snap-clips.
RECEPTACLE
5
8
7
5. Loosely fasten conduit clamps.
6. Determine direction of power and orient male and female ends of cable
assembly as required. Align ends flush with table edges and snap into clips.
Note: Infeed has a female connector.
7. Snap receptacle(s) into receptacle bracket(s).
8. Tighten conduit clamps.
9. Carefully flip tables upright into use position.
6
CABLE
CONNECTOR
WARNING
Risk of Fire or Electric Shock
CONDUIT
SNAP-CLIP
4
10. Make ganging connections between adjoining tables.
- Lack of mechanical connection may lead to cable damage.
11. Connect modular connectors.
3
- Match like colors only. (Green-to-Green, Red-to-Red,
Black-to-Black and White-to-White). Push connectors
together until both latches engage.
RECEPTACLE
BRACKET
Male end of Modular
Table Power Cable
BLACK
RED
GREEN
WHITE
Female end of Modular
Table Power Cable
BLACK
WHITE
RED
GREEN
Note: Latches
fully engaged.
11
Note: Orient colors on both
connectors to match.
Page 7 of 8
939505524 Rev C
Cable Routing Restrictions
In order for the flip-top mechanism to work properly,
the mechanism area - handle, swing arm, top pivot
and bumpers - must be free of any obstructions.
When routing power cables, follow the recommended
conduit path described on page 6, and avoid the
shaded areas in the illustration shown on this page.
Flip-Top mechanism must move
freely in shaded areas shown.
Do not route cables in these areas.
Page 8 of 8
939505524 Rev C