Assembly and Modular Table Power System Installation
Transcription
Assembly and Modular Table Power System Installation
Assembly and Modular Table Power System Installation Instructions for Train® Tables Topic Table of Contents Page Attach Stretcher to Legs 2 Attach Base To Table Top 3 Attach Modesty Panel to Assembly 4 Modular Table Power System Installation General Safety Warnings Ganging Hardware Electrical Circuits 5 5 5 5 Modular Table Power Assemblies 6 Installing Modular Cable for End-to-End Applications 7 Cable Routing Restrictions 8 Rectangular Tables Note: Refer to assembly direction # 939600192 for assembly of base power infeed. 90 Corner Top Modesty Panel If you have a problem, question, or request, call your local dealer, or Coalesse at 1.800.627.6770 Or visit our website: www.coalesse.com © 2015 Coalesse San Francisco, California U.S.A. Printed in U.S.A. Page 1 of 8 939505524 Rev C STRETCHER SHIPPED COMPONENTS: (1) Table top (2) Legs (1) Stretcher Attach Stretcher To Legs HARDWARE: Stretcher Hardware: (4) #730574 Allen Head Screws, 3/8-16 x 1” (2) #811679 Stretcher Joint Backer Plate (4) #732353 Lock Washers 2. Attach the stretcher to each leg casting. The Backer Plate (#811679) is installed on the outside of the casting as shown. The stretcher is attached to each leg casting with (2) Allen Head screws (#730574) and two lock washers. Table Top Mounting Hardware: (8) #A730461 Flathead Phillips wood screws, #10x7/8”, black 1. Unwrap the stretcher from package. BACKER PLATE LOCK WASHERS ALLEN HEAD SCREWS TOOLS REQUIRED: Electric Drill with 6” extension and: • #2 Phillips bit • T-27 Torx bit • 7/32” Allen wrench bit (NOTE: Hand tools may be substituted for the electric drill bits if necessary) WARNING: Protect top surface from scratches while attaching base feet. Page 2 of 8 939505524 Rev C Attach Base To Table Top 1. Carefully place table top upside down onto carpet or other soft, clean surface. Lower base assembly into place onto the table top. The leg attachment brackets should fit into the pockets routed into the underside of the table top. 1 2 2. Attach the leg attachment brackets to the table top using (3) #A730461 screws in each bracket. The 4th hole in the leg attachment brackets will be covered by the leg castings while the table is upside down. 1 Install (3) screws through each bracket at this time. ROUT 3. Carefully set the table right side up, then drop top into vertical position. This will give access to install the 4th screw in each bracket. TIP: Place a shim under carpet to allow a finger hold when assembled unit is ready to upright. SWING ARM 3 To drop table top into vertical position: A) disengage plastic sliders (both sides) B) rotate each swing arm toward the base C) rotate top into vertical position Page 3 of 8 939505524 Rev C SHIPPED COMPONENTS (1) modesty panel (1) hardware package MODESTY PANEL HARDWARE PACKAGE (4) (73053705) torx head screws, 1/4-20 x 1/2” (1) (811772R) right-hand bracket, R (1) (811772L) left-hand bracket, L (1) latchlock tape on each bracket TOOLS REQUIRED (1) electric drill or rachet with T-27 torx bit R Attach Modesty Panel To Assembly LATCHLOCK TAPE Note: To attach the modesty panel, Train table top must be flipped up. 1. 2. 3. 4. Brackets are identified with “L” or “R”. Attach the left-hand bracket, “L”, LOOSELY to the leg on the user’s left with (2) torx head screws. Attach the right-hand bracket, “R”, LOOSELY to the leg on the user’s right with (2) torx head screws. Attach modesty panel to table by slipping the clips over the stretcher. Align top of brackets with top of modesty panel. Also, adjust brackets on each side for the latchlock tape surface to fully contact the modesty panel. With upper modesty panel door open, peel off the protective backing of the latchlock tape to expose the adhesive. Close the modesty panel door and firmly press the door, adhering the latchlock tape on each bracket to the door. DO NOT OPEN THE MODESTY PANEL DOOR FOR 24 HOURS. For full cure the door should not be opened for 24 hours. 1 Attach bracket, facing outward, to inside of leg. BRACKET RH BRACKET FLIPPED TOP LH BRACKET CLIPS STRETCHER Page 4 of 8 939505524 Rev C Modular Table Power System Installation WARNING Risk of Fire or Electric Shock 12" MAX. 1. For use in indoor, dry locations only. 2. Read and install in accordance with all assembly directions. 3. Only connect to products labeled "Modular Table Power System" by Steelcase. 4. Do not modify or strain cables. If damaged, remove from service immediately. 5. Disconnect modular electrical connections before servicing or reconfiguring tables. 6. Tables must be held together with ganging hardware as described in this document, and NOT held together solely by electrical components. 7. Cable clamps must be no more than 12" from modular cable end connector or receptacle. Ganging Hardware SPIKE CABLE LENGTH 12" MAX. SLOT Electrical components MUST be accompanied by ganging hardware. Table-to-Table: Tables must be held together with table connection hardware, shown in illustration at right, NOT by electrical components. A coupling device is built into every Train Table to enable tables to gang together end-to-end without tools or separate parts. Electrical Circuits The modular table power kit is a 20 Amp, 4-wire, 2-circuit system. The 20 Amp plug infeed allows up to 13 circuit-1 duplex receptacles. The hardwire infeed allows up to 13 duplex receptacles per circuit for a total of 26. The duplex receptacle(s) in the table power kit and every two simplex receptacles from the desktop module count against the 13 duplex receptacles allowed for each circuit. Receptacle faces on the Modular Table Power Kits are marked I, for circuit 1 and II, for circuit 2. WARNING Neutral Ground Hot 2 Hot 1 White, 12 GA Green or no coating, 12 GA Red, 12 GA Black, 12 GA Risk of Fire or Electric Shock Note: All electrical installations must be reviewed with the local authority for compliance with local code, and must be performed by a qualified person in accordance with codes and regulations applicable at the installation site. Circuit 1 Circuit 2 Page 5 of 8 939505524 Rev C Modular Table Power Assemblies Single Receptacle Double Receptacle SHIPPED COMPONENTS: - 1 cable assembly - 1 hardware kit SHIPPED COMPONENTS: - 1 cable assembly - 1 hardware kit HARDWARE: - 1 receptacle bracket - 4 conduit clamps - 2 conduit snap-clips - 6 #10 phillips head screws - black - 2 #8 phillips head screws - zinc HARDWARE: - 2 receptacle brackets - 5 conduit clamps - 2 conduit snap-clips - 9 #10 phillips head screws - black - 2 #8 phillips head screws - zinc 2 TOOLS REQUIRED: #2 phillips head driver TOOLS REQUIRED: #2 phillips head driver Table Width Table Depth 24" 30" Cable attachment hole locations for single receptacle cable. 48" 60" 72" Cable Assembly Length 60" 72" 84" 54" 66" 78" Installing Modular Cable for End-to-End Applications Cable attachment hole locations for double receptacle cable. 2 1. Carefully place table top upside down onto rug or other soft, clean surface. 2. Single receptacle Identify the conduit path by locating (8) cable attachment holes: (2) for receptacle bracket, (4) for conduit clamps and (2) for conduit snap-clips. Double receptacle Identify the conduit path by locating (11) cable attachment holes: (4) for receptacle brackets (5) for conduit clamps and (2) for conduit snap-clips. If holes for double-receptacle brackets are not provided, use bracket as a template to mark hole locations near single-receptacle holes. Drill holes .157" dia x .50" deep. NOTE: Conduit clamps may be relocated for better cable fit. Drill clamp holes .157" dia x .50" deep. Page 6 of 8 939505524 Rev C Installing Modular Cable for End-to-End Applications (continued) 3. Fasten receptacle bracket(s). CONDUIT CLAMP 4. Fasten conduit snap-clips. RECEPTACLE 5 8 7 5. Loosely fasten conduit clamps. 6. Determine direction of power and orient male and female ends of cable assembly as required. Align ends flush with table edges and snap into clips. Note: Infeed has a female connector. 7. Snap receptacle(s) into receptacle bracket(s). 8. Tighten conduit clamps. 9. Carefully flip tables upright into use position. 6 CABLE CONNECTOR WARNING Risk of Fire or Electric Shock CONDUIT SNAP-CLIP 4 10. Make ganging connections between adjoining tables. - Lack of mechanical connection may lead to cable damage. 11. Connect modular connectors. 3 - Match like colors only. (Green-to-Green, Red-to-Red, Black-to-Black and White-to-White). Push connectors together until both latches engage. RECEPTACLE BRACKET Male end of Modular Table Power Cable BLACK RED GREEN WHITE Female end of Modular Table Power Cable BLACK WHITE RED GREEN Note: Latches fully engaged. 11 Note: Orient colors on both connectors to match. Page 7 of 8 939505524 Rev C Cable Routing Restrictions In order for the flip-top mechanism to work properly, the mechanism area - handle, swing arm, top pivot and bumpers - must be free of any obstructions. When routing power cables, follow the recommended conduit path described on page 6, and avoid the shaded areas in the illustration shown on this page. Flip-Top mechanism must move freely in shaded areas shown. Do not route cables in these areas. Page 8 of 8 939505524 Rev C