Bid Documents - Northwest Michigan Health Services Inc.
Transcription
Bid Documents - Northwest Michigan Health Services Inc.
DENTAL CLINIC RENOVATION PROJECT FOR: NORTHWEST MICHIGAN HEALTH SERVICES kendra c. THOMPSON architects, p.c. 803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 [email protected] www.kendrathompson-architects.com 119 STATE STREET SHELBY, MICHIGAN BID SET AUGUST 26, 2016 SCHEDULE OF DRAWINGS: BID SET 8/26/2016 5 DESIGN DEVELOPMENT REV. #3 7/07/2016 4 SCHEMATIC DESIGN REV. #2 01/21/2016 3 SCHEMATIC DESIGN REV. #1 01/20/2016 2 MASTER PLAN CONCEPT 01/16/2016 1 EXISTING MAIN LEVEL PLAN 01/14/2016 NO. REVISIONS / SUBMISSIONS DATE COVER SHEET SP100 GENERAL SPECIFICATIONS A200 A201 A202 EXISTING FLOOR PLAN DEMOLITION PLAN PROPOSED FLOOR PLAN AND REFLECTED CEILING/LIGHTING PLAN A500 INTERIOR ELEVATIONS, DETAILS AND DOOR & ROOM FINISH SCHEDULES MEP-1 SCHEMATIC MECHANICAL PLAN SCHEMATIC ELECTRICAL POWER PLAN ARCHITECT: Kendra C. Thompson Architects, P.C. 803 Cherry Street Manistee, MI 49660 t: 231.723.4195 PROJECT NAME DENTAL RENOVATION PROJECT NORTHWEST MICHIGAN HEALTH SERVICES 119 STATE STREET SHELBY, MICHIGAN DRAWING TITLE COVER SHEET SEAL DRAWN KCT PROJECT NO. KCT KT-2620B REVIEWED DRAWING NO. KCT T100 DATE HAN. 2016 SHEET NO. SCALE AS NOTED 1 OF 7 Copyright 2014 Kendra C. Thompson Architects, P.C. T100 6 188'-0" +/- kendra c. THOMPSON architects, p.c. 803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 [email protected] www.kendrathompson-architects.com COVERED ENTRY BREAK ROOM WAITING AREA DENTAL #3 WOM. TOIL. MENS TOIL. WAIT'G. TOIL. RECEPT. AREA OUTREACH STAFF MED. LAB/ STERIL. MEDICAL LAB DRAW STATION CLINIC COORDINATOR DENTAL LAB VITALS STATION DRAW STATION PATIENT TOIL. DENTAL #2 MEDS/ MEDICAL STOR. DENTAL #1 JAN. AREA DENTAL STAFF TOIL. 40'-0" +/- CONFERENCE ROOM W.I.C. DENTAL STERIL/ LAB AREA UNUSED STAFF ENTRY M.A. OFFICE MEDICAL EXAM #1 MEDICAL EXAM #2 MEDICAL EXAM #3 MEDICAL EXAM #4 BEHAVIORAL HEALTH BID SET 8/26/2016 5 DESIGN DEVELOPMENT REV. #3 7/07/2016 4 SCHEMATIC DESIGN REV. #2 01/21/2016 3 SCHEMATIC DESIGN REV. #1 01/20/2016 2 MASTER PLAN CONCEPT 01/16/2016 1 EXISTING MAIN LEVEL PLAN 01/14/2016 NO. REVISIONS / SUBMISSIONS DATE PROJECT NAME DENTAL RENOVATION PROJECT NORTHWEST MICHIGAN HEALTH SERVICES 119 STATE STREET SHELBY, MICHIGAN DRAWING TITLE N EXISTING MAIN LEVEL PLAN SCALE: 1/4" = 1'-0" EXISTING FLOOR PLAN SEAL DRAWN KCT PROJECT NO. KCT KT-2620B REVIEWED DRAWING NO. KCT A200 DATE JAN 2016 SHEET NO. SCALE AS NOTED 3 OF 7 Copyright 2015 Kendra C. Thompson Architects, P.C. REFERRAL COORDIANTOR MEDICAL PROVIDER OFFICE 6 kendra c. THOMPSON architects, p.c. 803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 [email protected] www.kendrathompson-architects.com INDICATES EXISTING PARTITION WALLS, DOORS, CEILINGS, CABS & EQUIP. TO BE REMOVED TO ACCOMMODATE NEW WORK PATCH & REPAIR AS REQ'D. MATCHING ADJACENT SURFACES 6 BID SET 8/26/2016 5 DESIGN DEVELOPMENT REV. #3 7/07/2016 4 SCHEMATIC DESIGN REV. #2 01/21/2016 3 SCHEMATIC DESIGN REV. #1 01/20/2016 2 MASTER PLAN CONCEPT 01/16/2016 1 EXISTING MAIN LEVEL PLAN 01/14/2016 NO. REVISIONS / SUBMISSIONS DATE PROJECT NAME DENTAL RENOVATION PROJECT NORTHWEST MICHIGAN HEALTH SERVICES 119 STATE STREET SHELBY, MICHIGAN N DEMOLITION PLAN SCALE: 1/4" = 1'-0" DEMOLITION PLAN SEAL DRAWN KCT PROJECT NO. KCT KT-2620B REVIEWED DRAWING NO. KCT A201 DATE JAN 2016 SHEET NO. SCALE AS NOTED 4 OF 7 Copyright 2015 Kendra C. Thompson Architects, P.C. DRAWING TITLE 11'-0" +/- 12'-6" +/- DENTAL EXAM #5 DENTAL EXAM #4 NEW NEW 108 107 10'-0" +/- THOMPSON architects, p.c. 5'-0" +/- 3'-1" CG CG CG CG EXISTING EXISTING EXISTING EXISTING 103 CG CG CG CG CORRIDOR TYPICAL NEW PARTITION: 1/2" GYP. BD. EA. SIDE OF 2X4 @ 16" O.C. W/SOUND ATTENUATION BLANKET - EXTEND WALLS TO HEIGHT OF EXIST'G. EXISTING 104 5 6 A500 101A 60" H. X 48" W. FRP PANEL @ NEW MOP SINK NEW MOP SINK CG CG JAN. NEW 101 NEW FLOOR'G. PATIENT TOILET 102 STAFF AREA (1) STAFF STATION SUPPLY AREA XRAY NEW 803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 [email protected] www.kendrathompson-architects.com 5'-1" +/- CG NEW FLOOR'G. DENTAL LAB CG NEW FLOOR'G. CG SCALES CG 106 EXISTING kendra c. NEW FLOOR'G. EXIST'G. CLOSET EXIST'G. FLOOR'G. W.I.C./MEDICAL EXAM #1 MEDICAL EXAM #2 MEDICAL EXAM #3 MEDICAL EXAM #4 MEDICAL EXAM #5 EXISTING EXISTING EXISTING EXISTING EXISTING N PROPOSED FLOOR PLAN SCALE: 1/4" = 1'-0" A2 (TYPICAL @ DENTAL EXAM): 2X2 LED ARCHITECTURAL TROFFER: METALUX #22EN-LD4-34-UNV-L850-CDI-U OR EQUAL, W/DIMMER EXIST'G. WOOD BEAMS TO REMAIN PAINT 8'-0" CLG 101B 8'-0" CLG NEW 2' X 2' ACT W/ METAL SUSPENSION SYSTEM @ NEW AREAS INDICATED (TYPICAL) INDICATES LINE OF PL. LAM. CLOSER PANEL @ WALL CABINETS (TYPICAL) S1 6 BID SET 8/26/2016 5 DESIGN DEVELOPMENT REV. #3 7/07/2016 4 SCHEMATIC DESIGN REV. #2 01/21/2016 3 SCHEMATIC DESIGN REV. #1 01/20/2016 2 MASTER PLAN CONCEPT 01/16/2016 1 EXISTING MAIN LEVEL PLAN 01/14/2016 NO. REVISIONS / SUBMISSIONS DATE S1 CONNECT TO EXIST'G. EXIST'G. CEILINGS TO REMAIN - PATCH/REPAIR DISTURBED AREAS PROJECT NAME DENTAL RENOVATION PROJECT NORTHWEST MICHIGAN HEALTH SERVICES S3 S3 8'-0" CLG 8'-0" CLG 8'-0" CLG S3 119 STATE STREET SHELBY, MICHIGAN DRAWING TITLE S3 A1 (TYPICAL @ LAB, XRAY, STAFF AREA) 2X2 LED ARCHITECTURAL TROFFER: METALUX #22CZ-LD4-24-UNV-L835-CDI-U OR EQUAL CONNECT TO EXIST'G. FLOOR PLAN & CLG/LTG. PLAN SEAL N REFLECTED CEIL'G./ LIGHTING PLAN SCALE: 1/4" = 1'-0" DRAWN KCT PROJECT NO. KCT KT-2620B REVIEWED DRAWING NO. KCT A202 DATE JAN. 2016 SHEET NO. SCALE AS NOTED 5 OF 7 Copyright 2015 Kendra C. Thompson Architects, P.C. EXIST'G. CLOSET CG NEW EXIST'G. FLOOR'G. CORRIDOR EXIST'G. CLOSET CG TYPICAL NEW CASED OPN'G: REMOVE EXIST'G. DOOR CASING, PROVIDE NEW GYP. BD. CASING W/POLYMER CORNER GUARDS WHERE INDICATED (CG) EXISTING 105 CG LAB/ STERILIZATION 1 NEW FLOOR'G. CG 2 EXISTING EXIST'G. FLOOR'G. 3 A500 REF. EXISTING EXIST'G. FLOOR'G. STAFF AREA EXISTING 4'-0" +/- 15'-5" +/- DENTAL EXAM #1 CG 3'-0" CG 6'-6 1/2" +/- CG DENTAL EXAM #2 CG EXIST'G. FLOOR'G. CG NEW FLOOR'G. CG NEW FLOOR'G. A500 SIM. EXIST'G. FLOOR'G. 4 9'-11" +/- BACKER BOARD COORD. EXACT LOCATION W/EQUIPMENT SUPPLIER A500 UNDERC. FREEZ. CG NEW FLOOR'G. EXIST'G. CLOSET 4 EXIST'G. FLOOR'G. 1" 2'-42 CG DENTAL EXAM #3 (3) STAFF STATIONS 7'-7 1/2" +/- 4X4 WD. POST FULL HGT. TO STRUCTURE ABOVE COORD. EXACT LOCATION W/ EQUIPMENT SUPPLIER EXIST'G. SPECIMEN TRANSFER TO REMAIN-INSTALL NEW PLAST. LAM. COVER TO MATCH CABS. B12 B48 BLIND 3'-0" kendra c. 4"H VINYL WALL BASE SB30 ADA COMPLIANT W/FIN. CLOSER PANEL TRASH 18 B27 LAB./ 2 STERILIZATION A202 SCALE: 1/2" = 1'-0" GYPSUM BOARD, PAINTED 2'-10" KNEE SPACE 4" VINYL WALL BASE LAB./ 3 STERILIZATION 1'-8" 1'-8" SCALES (BY OWNER) 4" VINYL BASE @ TOE SPACE B24 TOWER W3336 PLAST. LAM. COUNTER W/4" H BACKSPL. PLAST. LAM. CABS. W/LOCKS (TYPICAL) 4FT POLYMER CORNER GUARDS THOMPSON architects, p.c. B27 803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 [email protected] www.kendrathompson-architects.com LAB./ 1 STERILIZATION A202 SCALE: 1/2" = 1'-0" A202 SCALE: 1/2" = 1'-0" 6" PL. LAM. WALL CAB. W/ KEYED LOCKS PLAST. LAM. CLOSER GYP. BOARD, PAINTED CASED OPENING 1'-10" 16" H X FULL WIDTH FABRIC TACKBOARD W3032 GYP. BOARD, PAINTED W4212 W/ PL. LAM CLOSER PANEL KNEE SPACE PL. LAM. COUNTER ON KV BRACKETS W/MIN. (4) GROMMETS KNEE SPACE PLAST. LAM. COUNTER W/ 4" H. BACKSP. (BACK & SIDE) 3'-0" PL. LAM. COUNTER ON KV BRACKETS W/ MIN. (2) GROMMETS 3'-0" 16" 16" GYP. BOARD, PAINTED 16" H X FULL WIDTH FABRIC TACKBOARD PLAST. LAM. CABINETS W/ KEYED LOCKS 2'-8" 3'-8" V.I.F. 4'-2" V.I.F. (3) ADJUST. PL. LAM. SHELVES ON KV BRACKETS (3) ADJUST. PL. LAM. SHELVES ON KV BRACKETS 2'-6" 4" VINYL BASE @ TOE SPACE SB30 W/18" CURVED END 4" H. VINYL WALL BASE 4" H. VINYL WALL BASE STAFF 6 WORK AREA STAFF 5 WORK AREA A202 SCALE: 1/2" = 1'-0" NEW DENTAL 4 EXAM ROOMS A202 SCALE: 1/2" = 1'-0" 4FT POLYMER CORNER GUARDS A202 SCALE: 1/2" = 1'-0" 1 2" 1" 42 1" 32 6 BID SET 8/26/2016 5 DESIGN DEVELOPMENT REV. #3 7/07/2016 4 SCHEMATIC DESIGN REV. #2 01/21/2016 3 SCHEMATIC DESIGN REV. #1 01/20/2016 2 MASTER PLAN CONCEPT 01/16/2016 1 EXISTING MAIN LEVEL PLAN 01/14/2016 NO. REVISIONS / SUBMISSIONS DATE 1 2" 1/2" GYP. BOARD EA. SIDE ON 2x4 WOOD STUDS @ 16" O.C. W/SOUND ATTEN. BLANKET (NOTE: VERIFY EXIST'G. WALL CONSTRUCTION) SEE SCHEDULE (2) 2x6 WD. HEADER (OR AS OTHERWISE INDICATED ON DWGS.) SIZE 101A JAN. ROOM 3'-0" x 7'-0" x 1 3/4" 101B JAN. ROOM EXIST'G. 3'-0" x 7'-0" TYPE 1 - MAT. GLASS WD - WD - TYPE A - DETAIL MAT. FIRE HARDW. RATING GLASS HEAD JAMB HM - B/A500 A/A500 1 - - - - - 2 - REMARKS 5" VERIFY EXIST'G. 1 DOOR TYPES: 2" DOOR TYPE SEE DOOR SCHEDULE B HEAD A200 SCALE: 3" = 1'-0" 2" CL'G MT'L 101 JANITOR ROOM 4" VINYL LVT PLANKS GYP. BD., PAINT EXIST'G. 102 XRAY AREA MATCH EXIST'G. LVT PLANKS GYP. BD., PAINT NEW 2X2 ACT 103 STAFF AREA 4" VINYL LVT PLANKS GYP. BD., PAINT NEW 2X2 ACT GYP. BD., PAINT EXIST'G. GYP. BD., PAINT EXIST'G. 104 CORRIDOR, SOUTH MATCH EXIST'G. 105 CORRIDOR, NORTH MATCH EXIST'G. EXIST'G. TO REMAIN U.N.O. NEW LVT @ EAST END, EXIST'G. OTHERWISE 106 LAB/STERILIZATION 4" VINYL LVT PLANKS GYP. BD., PAINT NEW 2X2 ACT 107 DENTAL EXAM #4 4" VINYL LVT PLANKS GYP. BD., PAINT NEW 2X2 ACT 108 DENTAL EXAM #5 4" VINYL LVT PLANKS GYP. BD., PAINT NEW 2X2 ACT, EXIST'G. WOOD BMS-PAINT SCHEDULE REMARKS COORDINATE NEW CLG, FLOOR'G & WALL BASE W/EXIST'G. COORDINATE NEW INFILL WALL W/ EXIST'G FINISHES COORDINATE NEW WORK W/ EXIST'G FINISHES 5" WALL MT'L 1/2" GYP. BOARD EA. SIDE ON 2x4 WOOD STUDS @ 16" O.C. W/SOUND ATTEN. BLANKET (NOTE: VERIFY EXIST'G. WALL CONSTRUCTION) 1 2" FLOOR MT'L DOOR TYPE SEE DOOR SCHEDULE 2x4 WOOD NAILER 1 2" WALL BASE 1" 42 1" 32 ROOM NAME A FRAME TYPES: NORTHWEST MICHIGAN HEALTH SERVICES HOLLOW METAL FRAME SEE SEE SCHEDULE ROOM NO. ROOM FINISH SCHEDULE DENTAL RENOVATION PROJECT A JAMB 2" A200 SCALE: 3" = 1'-0" HOLLOW METAL FRAME 119 STATE STREET SHELBY, MICHIGAN DRAWING TITLE INT. ELEV. & SCHEDULES SEAL DRAWN KCT PROJECT NO. KCT KT-2620B REVIEWED DRAWING NO. KCT A500 DATE JAN. 2016 SHEET NO. SCALE AS NOTED 6 OF 7 Copyright 2015 Kendra C. Thompson Architects, P.C. LOCATION FRAME 2" DOOR PROJECT NAME SEE SCHEDULE DOOR NO. DOOR SCHEDULE 2" SB24 CASED OPENING W2136 PLAST. LAM. COUNTER W/ 4" H. BACKSP. 1'-10" 3'-0" UNDERCOUNTER FREEZER 24" WIDE (BY OWNER) W4236 2'-10" 5'-8" STERILIZER (BY OWNER) REFRIDGERATOR 30" WIDE (BY OWNER) W3336 BLIND 1'-8" GYP. BOARD, PAINTED 4'-0" 8'-0" (3) EQUAL W6236 ADJUST. SHELVES 8'-0" W3324 AUTOCL. (BY OWNER) 3'-0" 3'-0" (3) 12" D. PLAST. LAMINATE SHELVES ON METAL KV BRACKETS 3'-0" PLAST. LAM. CABINETS W/ KEYED LOCKS 6" 4" 6" 4" 1'-10" PLAST. LAM. CLOSER 2'-0" PLAST. LAM. CLOSER PANEL DENTAL CHAIR & EQUIP: CONTRACTOR TO PROVIDE ALL REQ'D. AIR, VACUUM AND WATER CONNECTIONS AS REQ'D. TO ACCOMMODATE NEW DENTAL CHAIR EQUIPMENT (PATTERSON: A-DEC #411, 332, 551 & 561 EQUIPMENT) PROVIDE 2" COPPER AIR LINES TO EXISTING AIR COMPRESSOR, 2" PVC SCH. 40 RISER THRU FLOOR TO EXISTING VACUUM FURNISH ALL CODE COMPLIANCE SHUT-OFF VALVES AS REQ'D. DENTAL EXAM #5 DENTAL EXAM #4 DENTAL EXAM #3 DENTAL EXAM #2 DENTAL EXAM #1 EXISTING EXISTING EXISTING EXIST'G. CLOSET S-3: 1-COMP. STAIN. STL. BOWL SINK 14 3/8" DIA. ELKAY #RLLVR12, TOP MTD., ADA W/AMERICAN STANDARD #6275.000.1424 9" GOOSENECK FAUCET, REMOV. STRAINER, CHROME STOPS 1/4 TURN SUPPLIES & P-TRAP STAFF AREA 803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 [email protected] www.kendrathompson-architects.com XRAY EXISTING PROVIDE ICE MAKER VALVE BOX EQUAL TO GUY GRAY W9700 W/ 1/4" TURN BALL VALVES EXISTING THOMPSON architects, p.c. EXISTING DENTAL LAB LAB/ STERILIZATION RECEPTION kendra c. CORRIDOR PATIENT TOILET SUPPLY AREA STAFF AREA EXISTING EXISTING EXISTING JAN. EXIST'G. CLOSET S-1: 1-COMP. STAIN. STL. SINGLE BASIN 25"X 21" X5 3/8" DP, 20-GA, ADA W/AMERICAN STANDARD #6275.000.1424 9" GOOSENECK FAUCET, REMOV. STRAINER, CHROME STOPS, 1/4 TURN SUPPLIES & P-TRAP CORRIDOR EXIST'G. CLOSET S-2: 1-COMP. STAIN. STL. SINGLE BASIN 19" X 19" 5" DP, 20-GA, ADA W/AMERICAN STANDARD #6275.000.1424 9" GOOSENECK FAUCET, REMOV. STRAINER, CHROME STOPS, 1/4 TURN SUPPLIES & P-TRAP EXISTING S-4: MOP SINK PROFLO PFMB2424 W/AMERICAN STANDARD #8344.111 WALL MOUNT FAUCET TOP BRACE, VACUUM BREAKER, STOPS, HOSE & HOSE CARRIER EXIST'G. CLOSET W.I.C./MEDICAL SCHEMATIC MECH. PLAN MEDICAL MEDICAL N MEDICAL MEDICAL SCALE: 1/4" = 1'-0" XRAY: 120V 5 AMP DEDICATED POWER PROVIDE CONDUIT TO REMOTE SWITCH @ CORRIDOR WALL) QUAD FLOOR BOX: 120V 5 AMP 4-PLEX DEDICATED POWER W/COMMUNICATION CHASE BELOW FLOOR BTWN. CHAIR & WALL MONITOR CONTROLS (BOX BY EQUIP. SUPPLIER, ALL CONNECTIONS BY ELECT. CONTRACTOR) WALL MTD. MONITOR/KEYBD: 120V, 8 AMP DUPLEX RECEPTACLE PROVIDE CONDUIT BTWN. MONITOR & CHAIR DENTAL EXAM #4 @ 18" @ 18" DENTAL EXAM #2 DENTAL EXAM #1 EXISTING EXISTING EXISTING @ 18" @ 18" EXIST'G. CLOSET GFI-A.C. GFI-A.C. EM: EMERGENCY FIXTURE LED W/ BATTERY BACKUP & (2) LTG HEADS EX: EXIT FIXTURE LED, WALL MTD. @ 18" LOW-VOLTAGE OPERATOR FOR XRAY @ 44"AFF W/ NON-LOCKING HINGED COVER BOX - COORD. W/ XRAY EQUIP. CONTRACTOR EXIST'G. EXIT LIGHT TO REMAIN (V.I.F.) (1) 120V, 20A @ 30"AFF (1) 120V, 20A @ 48"AFF RECEPTION DENTAL EXAM #3 STAFF AREA GFI-A.C. U.C. FREEZER @ 18" AFF GFI-A.C. @ 18" SCALES: @ 18" LAB/ STERILIZATION GFI-A.C. GFI-A.C. REFR: @ 18" AFF GFI-A.C. GFI-A.C. 5 DESIGN DEVELOPMENT REV. #3 7/07/2016 4 SCHEMATIC DESIGN REV. #2 01/21/2016 3 SCHEMATIC DESIGN REV. #1 01/20/2016 2 MASTER PLAN CONCEPT 01/16/2016 1 EXISTING MAIN LEVEL PLAN 01/14/2016 NO. REVISIONS / SUBMISSIONS DATE EXISTING DENTAL LAB XRAY PROJECT NAME DENTAL RENOVATION PROJECT NORTHWEST MICHIGAN HEALTH SERVICES @18" EXISTING SUPPLY AREA PATIENT TOILET LOW-VOLTAGE OPERATOR FOR XRAY @ 44"AFF W/ NON-LOCKING HINGED COVER BOX - COORD. W/ XRAY EQUIP. CONTRACTOR @18" @18" EXISTING STAFF AREA @18" EX: EXIT FIXTURE LED, WALL MTD. EXISTING @18" EXISTING @18" CORRIDOR EXISTING EXIST'G. CLOSET @18" EXIST'G. CLOSET 8/26/2016 CORRIDOR GFI-A.C. EXISTING BID SET EXIST'G. CLOSET JAN. XRAY EQUIP.: 120V, 15A DEDICATED OUTLET COORDINATE W/ EQUIP. CONTRACTOR TYPICAL DATA BOX: ELECT. CONTRACTOR TO PROVIDE BLANK BOX W/ 1" CONDUIT STUBBED ABOVE CEIL'G. - COVER & CABLING BY OWNER EX: EXIT FIXTURE LED, SIDE WALL MTD. 119 STATE STREET SHELBY, MICHIGAN DRAWING TITLE SCHEMATIC MEP PLANS SEAL W.I.C./MEDICAL MEDICAL N SCHEMATIC ELECTRICAL PLAN MEDICAL SCALE: 1/4" = 1'-0" MEDICAL MEDICAL DRAWN KCT PROJECT NO. KCT KT-2620B REVIEWED DRAWING NO. KCT MEP-1 DATE JAN. 2016 SHEET NO. SCALE AS NOTED 7 OF 7 Copyright 2015 Kendra C. Thompson Architects, P.C. DENTAL EXAM #5 6 GENERAL SPECIFICATIONS DIVISION 6 - WOOD AND PLASTICS Wood Framing All wood members shall be minimum 1050 psi bending stress materials, dressed lumber of S4S grade, (No. 2 Douglas Fir, Hem Fir or better) w/maximum 19% moisture content at time of dressing. Lumber in contact with concrete, masonry or earth shall be treated for contact of such. Install 1/2" compressible fiberglass blanket sill sealer at all sill plates. Finish Wood, interior All interior finish wood, including but not limited to baseboards, door casings and other misc. finish trim shall be coordinated with Owner. It is the intent to match existing trim profiles where appropriate. Finish Carpentry, miscellaneous components Furnish and install miscellaneous finish carpetry items, including shelf and counter brackets as indicated on drawings. Shelf standards shall be 12 ga. anochrome finish #87 ANO manufactured by Knape and Vogt. Shelf brackets shall be 12 ga. heavy duty anachrome finish #187LL by Knape and Vogt. All shelving and miscellaneous elements shown on drawings to be plastic laminate shall be shop fabricated plastic laminate face with laminate backing sheets on unexposed surfaces on medium density fiberboard (MDF) ANSI A208.2 with adhesive as specified by AWI standards. Plastic laminate color shall be selected by Architect from manufacturer's full range of colors, as manufactured by Formica, Wilsonart or approved equal. Submit shop drawings to Architect for review/approval prior to construction. Architectural Casework Furnish and install architectural casework as indicated on drawings. Casework shall be specially fabricated cabinet units consisting of high-pressure plastic laminate (0.048 HDPL) over 3/4-inch medium-denisty fiberboard (MDF) ANSI A208.2 with adhesive as specified by AWI standards. Plastic laminate at exposed surfaces shall be selected by Architect from manufacturer's full range of colors, as manufactured by Formica, Wilsonart or approved equal. Cabinet liner which are closed to view by doors may be "melamine" type panels. All other exposed surfaces, including tops and bottoms of wall hung cabinets, shall be HPDL. Drawer bottom, dust panels and similar shall be constructed using hardwood meeting AHA A135.4, pressed wood fiber with resin binder, Class I-tempered, 1/4-inch, smooth two sides. Construction shall include European style door/drawer hardware with full extension and self-closing mechanism. Casework shelving shall include adjustable shelf supports using multiple pin supports and coordinating rest supports with 1-inch spacing adjustment. Casework hardware shall be standard wire "C" pulls, 4-inch o.c., brushed aluminum finish. All casework shall be provided with standard keyed locks. Cabinet supplier shall coordinate all work and requirements with General Contractor. Submit shop drawings to Architect for review/approval prior to construction. Countertops: Plastic Laminate Furnish and install countertops as indicated on drawings. Plastic laminate countertops shall be high-pressure plastic laminate (0.048 inch HPDL) selected from manufacturer's full range of colors as manufactured by Formica, Wilsonart or approved equal. Plastic laminate countertops shall be 3/4-inch medium density fiberboard (MDF) substrate covered with HDPL, conventionally fabricated with HDPL edges. Provide backsplash of same construction where indicated on drawings. Submit product information to Architect for final color selection. Fiberglass Reinforced Panel (FRP) Furnish and install FRP panel at wall surface surrounding Janitor mop sink area. FRP panel shall extend from top of mop sink to 60-inch height above floor. FRP panel shall be adhered to gypsum board substrate. Provide standard FRP sheet, minimum 0.090-inch thickness, pebble finish as manufactured by Marlite or approved equal. Provide all required trims and accessories for a complete installation. DIVISION 7 - THERMAL AND MOISTURE PROTECTION Sealants Install sealant and backer rod where required to seal any joints, dissimilar material transitions and for watertightness. All interior sealants shall be acrylic latex or approved equal. Where required, exterior sealant shall be nonsag, polyurethane capable of continuous water immersion. Colors to match adjacent surfaces. Install sealant isolation at dissimilar metal connections. Install acoustic sealant at all new interior partitions. DIVISION 8 - DOORS AND WINDOWS Interior Flush Wood Doors Furnish and install pre-hung wood frame, flush interior wood doors as indicated on drawings. Acceptable manufacturer's are Graham Doors, Marshfield Doors or approved equal. Doors shall be 1-3/4 inch thick, with honey-comb core and face veneer maple species, rift cut with slip-matched grain with edges of same species. Construct and finish doors in accordance with AWI standards. Doors shall be factory machined for finish hardware. Factory finish doors in accordance with AWI Quality Standards Section 1500 for transparent catalyzed polyurethane, satin sheen. Install doors per manufacturer's instructions and AWI standards. Coordinate final species and finish with Owner. Hollow Metal Frames Furnish and install hollow metal frames where indicated on drawings. Frames shall be factory primed with rust inhibiting primer complying with ANSI A250.10, ready for field finishing. HM frames shall be 14 ga frames. All frames shall be equipped with resilient rubber silencers, 3 on strike side of single door. Frames indicated to be fire-rated shall bear the certification plate of UL or other approved testing agency for rating specified. Prep for door hardware in accordance with BHMA A 156.115 with reinforcement welded in place. Hardware All door hardware shall meet the requirements of the Michigan Barrier-Free and ADA regulations (lever type or equal). Finishes to be standard US26D/BHMA 626 dull chrome or equal. Keying per Owner. Standard of goods shall be Schlage D-series locksets, LCN closers, Stanley hinges or approved equal. Hardware Set 1: (3) Hinges (1) Storage Lockset (1) Surface Closer (1) Wall Stop (1) Kickplate (3) Silencers 5BB1 4.5x4.5 ND 80 PD 4011 WSA407 CCV K3125 10" x 2" LDW SR64 kendra c. THOMPSON architects, p.c. 803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 [email protected] www.kendrathompson-architects.com Ive Schlage LCN Ive Rock Ive Hardware Set 2: Existing hardware to remain, except install new: (1) Storage Lockset ND 80 PD Schlage DIVISION 9 - FINISHES Gypsum Board Furnish and install standard paper-faced gypsum board ASTM C1396 as manufactured by US Gypsum or approved equal. Provide 1/2-inch minimum thickness at walls, 5/8-inch at all ceiling construction and 5/8-inch Type 'X' fire-rated where indicated on drawings. Provide all cornerbeads, casing beads and other miscellaneous trim as required for a neat and complete installation. All gypsum board shall be glued and fastened with screws. Screws shall be self-tapping type located at 12" o.c. Install product in strict accordance with manufacturers instructions. Provide Level 4, ready for painting. Acoustic Ceilings and Metal Suspension System Furnish and install suspended metal grid ceiling system and acoustic ceiling panels as indicated on drawings. Acoustic ceiling panels shall be as follows: ACT-1: "Cortega" as manufactured by Armstrong World Industries Size: 24 inch by 24 inch by 5/8-inch thickness Edge: Reveal edge Surface Color: White Surface Pattern: Non-directional fissured Metal suspension system shall be manufactured by same as acoustic panel units, equal to "Prelude XL" 15/16-inch tee system by Armstrong World Industries. Suspension system shall comply with ASTM C635 die-cut, interlocking components complete with stabilizer bars, clips, edge trim and all accessories to provide a complete installation. Installation shall be in accordance with ASTM C 636, ASTM E 580 and manufacturer's instructions. Hold-down clips shall be installed on acoustic panels within 20 feet of an exterior door. Submit product information to Architect for review/approval prior to construction. Vinyl Plank Flooring (LVT) and Wall Base Furnish and install LVT (vinyl plank) flooring and resilient wall base where indicated on Room Finish Schedule and drawings. LVT shall be "Freelay Heritage Wood" as manufactured by Milliken Co., color: HER-208, or approved equal. Vinyl flooring shall be 9-inch wide x 60-inch length, installed randomly. Provide 28 mil wear layer, 5 mm overall product thickness. LVT shall comply with ASTM F970 for static load limit. Flooring shall comply with ADA requirements for slip-resistance. Installation of LVT shall be free lay with perimeter adhesive in accordance with manufacturer's installation recommendations. Resilient base shall be ASTM F 1861, Type TS rubber. Provide resident base of 4-inch by 0.125-inch thick, satin finish with premolded external corners and end stops as manufactured by Johnsonite, Roppe or approved equal. Colors to be selected from full range of colors. Install in accordance with manufacturer's instructions. Submit product information for Architect review/approval prior to construction. Painting All interior surfaces shall receive finish paint or stain. Color as selected by Owner. Where painting is required use the following schedule: Interior Gypsum: Interior Wood, painted: Interior Wood, stained: 6 BID SET 8/26/2016 5 DESIGN DEVELOPMENT REV. #3 7/07/2016 4 SCHEMATIC DESIGN REV. #2 01/21/2016 3 SCHEMATIC DESIGN REV. #1 01/20/2016 2 MASTER PLAN CONCEPT 01/16/2016 1 EXISTING MAIN LEVEL PLAN 01/14/2016 NO. REVISIONS / SUBMISSIONS DATE Primer - 1 coat - Latex Base Primer; Finish - 2 coat - Satin Latex Primer - 1 coat - Latex Base Primer; Finish - 2 coat - Satin Latex Stain - 1 coat - Color selected by Owner; Sealer - 2 coat - Polyurethane PROJECT NAME Standard of Goods: Sherwin Williams; Martin Seynour; Valspar or approved equal. DIVISION 10 - EQUIPMENT DENTAL RENOVATION PROJECT NORTHWEST MICHIGAN HEALTH SERVICES Corner Guards Furnish and install surface-mounted polymer cover corner guards similar to Acrovyn 4000 Model #SSM-20N, or approved equal. Corner guards shall be install where indicated on drawings. Assembly shall consist of manufacturer's standard prefabricated unit of snap-on, resilient plastic cover installed over retainer, including mounting hardware. Cover shall be extruded rigid plastic, minimum 0.078-inch wall thickness, 2-inches wide with 1/4-inch radius corner. Retainer clips shall be manufacturer's standard non-corrosive impact absorbing clips. Top and bottom caps shall be prefabricated manufacturer's standard matching cover color. Color shall be selected by Architect from manufacturer's full range of colors. 119 STATE STREET SHELBY, MICHIGAN DIVISION 15 - MECHANICAL & DIVISION 16 - ELECTRICAL DRAWING TITLE Mechanical, plumbing and electrical work shall be developed on a design-build arrangement. Design and installation shall be in strict compliance with the latest edition of the Michigan Mechanical Code, Michigan Plumbing Code-Part 7, National Electric Code and other federal, state and local requirements as they may apply. Trade contractors shall coordinate all work and associated requirements with General Contractor and related trades. GENERAL SPECS Drawings reflect general design intentions and are for establishing the schematic scope of work only. Trade contractors shall aquaint themselves with the existing conditions to determine work requirements for completing the design renovations proposed. Owner equipment contractor will provide equipment shop drawings prior to construction for trade contractors use in determining final equipment requirements, locations and template diagrams. SEAL DRAWN KCT PROJECT NO. KCT KT-2620B REVIEWED DRAWING NO. KCT DATE JAN. 2016 SP100 SHEET NO. SCALE AS NOTED 2 OF 7 Copyright 2015 Kendra C. Thompson Architects, P.C. DIVISION 0 - CONDITIONS OF THE CONTRACT Scope of the Work The scope of work includes, but not limited to, the furnishing materials and providing labor to complete all work required for the proposed interior renovation project to accommodate two new dental exam and lab/sterilization area at the existing facilities for Northwest Michigan Health Services located at 119 S. State Street, Shelby, Michigan. Governing Regulations All Work shall be performed in strict conformance with State of Michigan Building Code (IBC 2012, as amended), Michigan Barrier-free Regulations, Americans with Disabilities Act (ADA) as applicable and most current editions of the Michigan Mechanical Code, Michigan Plumbing Code, National Electrical Code, National Fire Protection Code (NFPA) and other state and local regulations as they may apply. Licensing and Permit Fees General and trade contractors shall be licensed by the State of Michigan for their respective trade. Contractors are responsible for obtaining and paying for required permits and inspections as associated with their respective trade. Insurance Contractors shall provide Certificate of Insurance covering statuary insurance requirements for workman's compensation insurance and other as applicable. Provide general liability insurance of $1,000,000 minimum per occurance. The Owner and Architect shall be named as co-insured for the duration of the project. Product Samples and Substitutions It shall be required that the contractor submit material samples and shop drawings for the primary components of this project to the Architect. Additionally, Contractor shall complete all work in accordance with equipment supplier's shop drawing submittals. Where specific materials are specified, provide only that product unless approved prior to installation by the Architect. Colors to be selected by Architect from manufacturer's standard range of colors. Drawings Do NOT scale drawings. Use dimensional figures only. Contractor shall verify all dimensions prior to construction and shall be responsible for same. Notify Architect immediately of any discrepancies, dimensional errors, or existing conditions that effect the design intent. Dimensional figures are from face of wall to face of wall, typically. DIVISION 1 - GENERAL REQUIREMENTS Building Information B, business Use Group: Square Footage, 4,785 s.f. gross exterior Overall Existing: 560 s.f. gross interior Renovation Area: 5B, combustible, non-protected Construction Type: None Fire Suppression: 45 persons Occupancy: