EAC 132 - 11 kV Omonoia Substation
Transcription
EAC 132 - 11 kV Omonoia Substation
www.emf.ucy.ac.cy/emfmap EAC 132 - 11 kV Omonoia Substation The measured substation is located in Omonoia area in Limassol. The measurements were performed on the 24th of October 2008 at 11:00 am. The EAC 132-11 kV Substation in Omonoia comprises of a main building which includes a basement where the incoming and outgoing cables are mounted, three rooms where the transformers are located, a room where the incoming and outgoing switchgear breakers are installed and a working area with the control rooms of the substation. In direct proximity to the substation are a number of houses and shops. {mosmap width='500'|height='400'|lat='34.674167'|lon='33.016389'|zoom='2'|zoomType='Large'|zoomNew='0'|mapType='Satellit e'|showMaptype='1'| overview='0'|text='EAC 132 - 11 kv Omonoia Substation'|tooltip='DWO'|marker='1'| align='center'|key=ABQIAAAA03CWbwhNzyJiZSn-wWDqMhQCTkyp5L8hB2mJnGVvFKVPdGzBixQKqItRaFiGip chx6GPLPhdiDvZgA} Σελίδα 1 / 9 www.emf.ucy.ac.cy/emfmap EAC 132 - 11 kV Omonoia Substation Limiting exposure values have been provided by the ICNIRP recommendations and are guidelines to many countries and organisations. The exposure limits at 50 Hz are tabulated in the following table according to the limits given by ICNIRP. Reference levels for Occupational exposure ICNIRP Σελίδα 2 / 9 www.emf.ucy.ac.cy/emfmap EAC 132 - 11 kV Omonoia Substation Frequency Electric Field Strength, E (V/m) Magnetic Field Strength, H (A/m) Magnetic Flux Density, B (µT) 50 Hz 10000 400 500 Reference levels for General Public exposure ICNIRP Frequency Electric Field Strength, E (V/m) Magnetic Field Strength, H (A/m) Magnetic Flux Density, B (µT) 50 Hz 5000 80 100 Table 1: ICNIRP exposure limits for Occupational and General public exposure The power as measured from the two operating transformers, at the time when the measurements were performed is listed below: Time Transformer 1 Power [MW] Σελίδα 3 / 9 www.emf.ucy.ac.cy/emfmap EAC 132 - 11 kV Omonoia Substation Transformer 2 Power [MW] 11:40 am 4.5 7.4 Table 2: Maximum Power consumption recorded during EMF measurements for substation Omonoia The power transformers have an operating capacity of 30 MW and a full power capacity of 40 MW with the fans operating. The highest magnetic field inside the substation was observed in the Transformer 2 room (in front of the 11 kV cable side), with a value 461.7 µT and a percentage of 92.34% as compared to the ICNIRP Occupational standard. Accordingly the Magnetic Field measurements taken both inside and outside the power station are summarized in the following tables. Substation : Inside Maximum Field Measurements Distance from Side (m) Maximum Magnetic Field (µT) at Z Height (m) Percentage of ICNIRP General Public Standard (%) 0.3m ICNIRP % 1m ICNIRP % 1.75 m ICNIRP % Control room 11 kV Σελίδα 4 / 9 www.emf.ucy.ac.cy/emfmap EAC 132 - 11 kV Omonoia Substation Incomer 2 -- -- -- -- 49.60 9.92% Power factor correction room Room -- -- 0.19 0.04% -- -- Transformer room 1 Transformer 1 - 11kv 400.6 80.12% ----- Σελίδα 5 / 9 www.emf.ucy.ac.cy/emfmap EAC 132 - 11 kV Omonoia Substation Transformer room 2 Transformer 2 - 11kv 461.7 92.34% ----Incoming - Outgoing cables 11 - 132 kV cables 67.0 13.40% ----Control room 132 kV Point A 19.28 3.86% Σελίδα 6 / 9 www.emf.ucy.ac.cy/emfmap EAC 132 - 11 kV Omonoia Substation Table 3: Maximum Magnetic Field measurements inside power station Accordingly the highest magnetic field value outside the substation was observed at the right border side (at a height of 0.3m), with value 2.66 µT and a percentage of 2.66 % as compared to the ICNIRP General Public standard. Substation : Outside Maximum Field Measurements Distance from Side (m) Maximum Magnetic Field (µT) at Z Height (m) Percentage of ICNIRP General Public Standard (%) 0.3m ICNIRP % 1m ICNIRP % 1.75 m ICNIRP % Outside substation Left outside wall 0.95 0.95% --- --- Σελίδα 7 / 9 www.emf.ucy.ac.cy/emfmap EAC 132 - 11 kV Omonoia Substation Front outside wall 0.51 0.51% - - - -Right outside wall 4.68 4.68% - - - -Back outside wall 0.41 0.41% - - - -Other outside wall 2.66 2.66% Σελίδα 8 / 9 www.emf.ucy.ac.cy/emfmap EAC 132 - 11 kV Omonoia Substation --- - -Table 4: Maximum Magnetic Field measurements outside power station Σελίδα 9 / 9
Similar documents
Kuala Lumpur 1 Utama Shopping Mall | Shogun Japanese Buffet
Direction: Saisaki -First Wisma UOA omNew='0'|mapType=''|showMaptype='1'|overview='0'|text='Shogun width='460'|height='400'|address=''|lat='3.1523'|lon='101.7121'|zoom='15'|zoomType='Large'|zo
More information