the many Possibilities with am 1200
Transcription
the many Possibilities with am 1200
function and design a priority AM 1200 is a floor-mounted unit available in a horizon- Ventilation should not just be seen as a technical com- tal and vertical model. The unit can be placed against a ponent: it also plays an active role in a room’s function. wall (right/left variant) or free-standing (centre variant). In the field of decentralised ventilation, the AM 1200 is With the various types of panel design, the surface a byword for combining fresh air and elegant design. It can be used as a notice board, mirror or equipped with has a lot more uses than you might think. acoustic boards – the sky is the limit. product information am 1200 AM 1200 The many possibilities with AM 1200 airmaster Visualizer Design your own AM 1200 with Airmaster VISUALISER at www.airmaster.dk With Airmaster, you are not only choosing a responsible solution. You are also choosing a solution for the future. 64 Visit www.airmaster.dk to design, choose, save and print your very own design. 65 35 dB(A) 30 dB(A) right/left 1180 m /h centre 1310 m /h 3 3 90° C 930 m /h Maximum operating pressure 10 bar 1050 m /h Heating capacity 2240 W* Connection dimension 3/4" (DN 20) Material of pipes/louvres copper/aluminium 3 3 Vertical, Ø400 mm right/left centre 1130 m3/h 1260 m3/h 870 m3/h 980 m3/h right/left 1060 m3/h 820 m3/h centre 1170 m /h 920 m3/h 3 TECHNICAL DATA Throw (0.15 m/s) – right/left Opening/closing time of motorised valve <60 s * Capacity at: flow/return temperature of 65/35°, volume of water 72 l/h Vertical, Ø315 mm Throw (0.15 m/s) - centre water heating surface (optional) Maximum operating temperature Horizontal product information am 1200 capacity Electrical heating surface (optional) Preheating Comfort heating Min. 4.5 m at 1000 m3/h Heating element 1 x 230 V 1 x 230 V Max. 5.5 m at 1000 m3/h Heating capacity 2500 W 1670 W Min. 5.5 m at 1300 m3/h Thermal cut-out, automatic reset 70° 70° Max. 7.0 m at 1300 m3/h Thermal cut-out, manual reset 120° 120° Min. 6.5 m at 1000 m3/h Max. 7.5 m at 1000 m3/h Min. 7.5 m at 1300 m3/h Max. 9.5 m at 1300 m3/h Electrical connection – with preheating surface 3~230 V + N + PE/50 Hz (note: preheating surface to be provided with a dedicated phase) Electrical connection 1~230 V + N + PE/50 Hz Duct connection Ø400 mm Condensate drain Weight Standard & Optional Features vertical model centre vertical model right/left horizontal model horizontal model centre right/left Ø16 mm Bypass x x x x Centre model 630 kg Electrical heating surface (preheating) Right-/left model 545 kg Electrical heating surface (comfort heating) Heat exchanger 4 countercurrent exchangers (aluminium) Water heating surface (comfort heating) Filter F5 standard, F7 for fresh air optional item CO2 sensor (wall-mounted) Current Unit without electrical heating surface 1.4 A CO2 sensor (integrated) Electrical preheating surface 10.9 A PIR/motion sensor Electrical comfort heating surface 7.3 A Humidity sensor Supply cable 1.5 mm2 Thermostat Maximum power consumption 254 W Condensate pump • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Leakage current <– 9 mA Cooling unit – – – – Spring-return actuator on main damper (for fresh air and exhaust air) x x x x Countercurrent heat exchanger (aluminium) x x x x x : standard 66 • : optional – : not available 67 Horizontal model AM 1200 schematic diagram Centre* EXHAUST Right INTAKE Left Vertical model product information am 1200 installation position model PI 4 3 Centre* MD MD Right PH Left PE IF * If the centre model is required to be of freestanding type, a back panel is fitted to finish it off (option). FI F2 BP ET 1 EF BP HE EXTRACTION 2 1: Right and left (mounting in the corner) 2: Right and left (mounting along the wall) OT RT FL FT 3: Centre (mounting against the wall) CT CP 4: Centre (mounting as free-standing) CH + IT INLET AM 1200 Panel designs Colours Size Chipboard with melamine White 600x500 Chipboard with melamine Black 600x500 MDF Lacquered (all colours) 600x500 MDF Lacquered (all colours) 1200x1000 MDF with whiteboard laminate White 1200x1000 MDF with notice board surface Black 1200x1000 Mirror bonded to MDF Mirror 1200x1000 Sound-absorbing wood (Acoustic Lightboard) White 1200x1000 White 1200x1000 Sound-absorbing foam, printed/unprinted Name of component Inlet fan F1 Exhaust fan F2 IF Fresh air filter EF Exhaust air filter MD Main damper (motorised) BP Bypass damper HE Countercurrent heat exchanger CT Condensate tray CP Condensate pump FTFloat RT/FL Room temperature sensor/flow sensor OT Outdoor temperature sensor ET Exhaust temperature sensor PI PE PH CH IT Connection for pressure gauge for airflow-measurement, inlet Connection for pressure gauge for airflow-measurement, extraction Preheating surface (optional) Comfort heating surface Inlet temperature sensor AM 1200 has a spring-return actuator on the main d ampers as standard, both on the intake and exhaust. AM 1200 Colour options Lacquered MDF boards are supplied in the standard colours shown, but all RAL colours are available at an additional cost. 68 69 AM 1200 v capacity (%) - Ø400 mm 100 100 90 90 80 80 70 70 60 Right/left 35 dBA 40 Centre 30 dBA 30 Right/left 30 dBA 20 300 60 Centre 35 dBA 50 400 500 600 700 800 900 1000 1100 1200 1300 Centre 35 dBA 50 Right/left 35 dBA 40 Centre 30 dBA 30 20 300 Right/left 30 dBA 400 500 600 100 90 80 70 60 Centre 35 dBA 50 Right/left 35 dBA 40 Centre 30 dBA 30 Right/left 30 dBA 20 500 600 700 800 900 1000 1100 1200 1300 40 38 36 34 32 30 28 26 24 22 20 500 350 38 300 36 34 250 32 200 30 28 24 22 900 1300 600 700 800 1000 1100 1200 1300 1100 1200 1300 500 1400 70 60 50 120 Centre, 30 dBA Right/left, 35 dBA Right/left, 30 dBA 100 900 1000 1100 1200 1300 1400 900 1100 1200 1300 1100 1200 1300 1400 Centre, 35 dBA Centre, 30 dBA Right/left, 35 dBA Right/left, 30 dBA 0 500 600 700 800 900 1000 1100 1200 1300 500 1400 600 700 800 900 1000 1100 1200 1300 1400 Airflow (m3/h) AM 1200 v External pressure drop (Pa) – Ø315mm - fresh air 1000 1000 Roof cap Ø400 mm Airflow (m3/h) Vertical Ø400 mm 900 20 100 90 80 70 60 50 40 30 20 10 0 800 800 60 10 Horizontal 700 700 40 20 Vertical Ø315 mm 600 600 80 0 800 Centre, 30 dBA Right/left, 35 dBA Right/left, 30 dBA 140 Centre, 35 dBA 30 Centre Right/left 700 Centre, 35 dBA AM 1200 v External pressure drop (Pa) – Ø400 mm - exhaust 40 600 Wall grille Airflow (m3/h) Roof cap Ø400 mm AM 1200 v External pressure drop (Pa) – Ø315mm - exhaust 140 Roof cap Ø315 mm Centre, 35 dBA 120 Centre, 30 dBA Right/left, 35 dBA Right/left, 30 dBA 100 Roof cap Ø315 mm Centre, 35 dBA Centre, 30 dBA Right/left, 35 dBA Right/left, 30 dBA 80 60 40 20 500 600 Airflow (m3/h) AM 1200 SFP W/(m3/s) 1000 90 50 1400 900 AM 1200 v External pressure drop (Pa) – Ø400 mm -fresh air 100 0 500 100 90 80 70 60 50 40 30 20 10 0 Airflow (m3/h) 80 Airflow (m3/h) 1000 900 800 700 600 500 400 300 200 100 0 500 1200 150 Ø315 mm centre Ø315 mm right/left Ø400 mm centre Ø400 mm right/left 26 800 1100 AM 1200 Power consumption (W) 40 700 1000 Airflow (m3/h) AM 1200 v Sound pressure level (dB(A)) 600 900 AM 1200 h External pressure drop (Pa) – exhaust air Wall grille Centre, 35 dBA Centre, 30 dBA Right/left, 35 dBA Right/left, 30 dBA 100 Airflow (m3/h) 20 500 800 AM 1200 h Sound pressure level (dB(A)) AM 1200 v capacity (%) - Ø315 mm 400 700 120 110 100 90 80 70 60 50 40 30 20 10 0 500 Airflow (m3/h) Airflow (m3/h) 300 AM 1200 h External pressure drop (Pa) – fresh air product information am 1200 AM 1200 h capacity (%) 700 800 900 1000 1100 1200 1300 0 500 1400 600 700 800 900 1000 1100 1200 1300 1400 Airflow (m3/h) Airflow (m3/h) AM 1200 Temperature efficiency (%) 88 87 AM 1200 Throw (0.15 m/s) 86 0m 85 Vertical Ø315 mm Horizontal Vertical Ø400 mm 600 700 800 900 Airflow (m3/h) 1000 1100 1200 1300 11m 1 84 83 82 500 600 700 800 900 1000 1100 1200 1300 m3/h Max. Min. 1000 m3/h Max. Min. 1300 Airflow (m3/h) AM 1200 The Airmaster units provide different air throw lengths depending on supply air volume. The blue tones on the illustration on the left show the airflow at different throws. AM 1200 2 70 1 2 Throw viewed from above Throw viewed from the side 71 AM 1200 h (horizontal) - right product information am 1200 AM 1200 h (horizontal) - centre AM 1200 h (horizontal) - left 72 73 AM 1200 V (vertical) - right AM 1200 V (vertical) - left AM 1200 roof cap unit Ø315 product information am 1200 AM 1200 V (vertical) - Centre A panel box is available for the roof cover module to cover intake and exhaust. White as standard. 74 75