AM 1200 is a floor-mounted unit available in a horizon-
Ventilation should not just be seen as a technical com-
tal and vertical model. The unit can be placed against a
ponent: it also plays an active role in a room’s function.
wall (right/left variant) or free-standing (centre variant).
In the field of decentralised ventilation, the AM 1200 is
With the various types of panel design, the surface
a byword for combining fresh air and elegant design. It
can be used as a notice board, mirror or equipped with
has a lot more uses than you might think.
acoustic boards – the sky is the limit.
product information am 1200
AM
1200
The many
possibilities
with AM 1200
airmaster
Visualizer
Design your own AM 1200
with Airmaster VISUALISER
at www.airmaster.dk
With Airmaster, you are not only
choosing a responsible solution. You are
also choosing a solution for the future.
64
Visit www.airmaster.dk to
design, choose, save and
print your very own design.
65
35 dB(A)
30 dB(A)
right/left
1180 m /h
centre
1310 m /h
3
3
90° C
930 m /h
Maximum operating pressure
10 bar
1050 m /h
Heating capacity
2240 W*
Connection dimension
3/4" (DN 20)
Material of pipes/louvres
copper/aluminium
3
3
Vertical, Ø400 mm
right/left
centre
1130 m3/h
1260 m3/h
870 m3/h
980 m3/h
right/left
1060 m3/h
820 m3/h
centre
1170 m /h
920 m3/h
3
TECHNICAL DATA
Throw (0.15 m/s) – right/left
Opening/closing time of motorised valve <60 s
* Capacity at: flow/return temperature of 65/35°, volume of water 72 l/h
Vertical, Ø315 mm
Throw (0.15 m/s) - centre
water heating surface (optional)
Maximum operating temperature
Horizontal
product information am 1200
capacity
Electrical heating surface
(optional)
Preheating
Comfort heating
Min. 4.5 m at 1000 m3/h
Heating element
1 x 230 V
1 x 230 V
Max. 5.5 m at 1000 m3/h
Heating capacity
2500 W
1670 W
Min. 5.5 m at 1300 m3/h
Thermal cut-out, automatic reset
70°
70°
Max. 7.0 m at 1300 m3/h
Thermal cut-out, manual reset
120°
120°
Min. 6.5 m at 1000 m3/h
Max. 7.5 m at 1000 m3/h
Min. 7.5 m at 1300 m3/h
Max. 9.5 m at 1300 m3/h
Electrical connection
– with preheating surface
3~230 V + N + PE/50 Hz (note: preheating surface to be provided with a dedicated phase)
Electrical connection
1~230 V + N + PE/50 Hz
Duct connection
Ø400 mm
Condensate drain
Weight
Standard & Optional Features
vertical model
centre
vertical model
right/left
horizontal model horizontal model
centre
right/left
Ø16 mm
Bypass
x
x
x
x
Centre model 630 kg
Electrical heating surface (preheating)
Right-/left model 545 kg
Electrical heating surface (comfort heating)
Heat exchanger
4 countercurrent exchangers (aluminium)
Water heating surface (comfort heating)
Filter
F5 standard, F7 for fresh air optional item
CO2 sensor (wall-mounted)
Current
Unit without electrical heating surface 1.4 A
CO2 sensor (integrated)
Electrical preheating surface 10.9 A
PIR/motion sensor
Electrical comfort heating surface 7.3 A
Humidity sensor
Supply cable
1.5 mm2
Thermostat
Maximum power consumption
254 W
Condensate pump
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Leakage current
<– 9 mA
Cooling unit
–
–
–
–
Spring-return actuator on main damper
(for fresh air and exhaust air)
x
x
x
x
Countercurrent heat exchanger (aluminium)
x
x
x
x
x : standard
66
• : optional
– : not available
67
Horizontal model
AM 1200 schematic diagram
Centre*
EXHAUST
Right
INTAKE
Left
Vertical model
product information am 1200
installation position
model
PI
4
3
Centre*
MD
MD
Right
PH
Left
PE
IF
* If the centre model is required to be of freestanding type, a back panel is fitted to finish it
off (option).
FI
F2
BP
ET
1
EF
BP
HE
EXTRACTION
2
1: Right and left (mounting in the corner)
2: Right and left (mounting along the wall)
OT
RT
FL
FT
3: Centre (mounting against the wall)
CT
CP
4: Centre (mounting as free-standing)
CH
+
IT
INLET
AM 1200 Panel designs
Colours
Size
Chipboard with melamine
White
600x500
Chipboard with melamine
Black
600x500
MDF
Lacquered (all colours)
600x500
MDF
Lacquered (all colours)
1200x1000
MDF with whiteboard laminate
White
1200x1000
MDF with notice board surface
Black
1200x1000
Mirror bonded to MDF
Mirror
1200x1000
Sound-absorbing wood
(Acoustic Lightboard)
White
1200x1000
White
1200x1000
Sound-absorbing foam,
printed/unprinted
Name of component
Inlet fan
F1
Exhaust fan
F2
IF
Fresh air filter
EF
Exhaust air filter
MD
Main damper (motorised)
BP
Bypass damper
HE
Countercurrent heat exchanger
CT
Condensate tray
CP
Condensate pump
FTFloat
RT/FL Room temperature
sensor/flow sensor
OT
Outdoor temperature sensor
ET
Exhaust temperature sensor
PI
PE
PH
CH
IT
Connection for pressure gauge for
airflow-measurement, inlet
Connection for pressure gauge for
airflow-measurement, extraction
Preheating surface (optional)
Comfort heating surface
Inlet temperature sensor
AM 1200 has a spring-return actuator on the main d
­ ampers as standard, both on
the intake and exhaust.
AM 1200 Colour options
Lacquered MDF boards are supplied in the standard colours shown,
but all RAL colours are available at an additional cost.
68
69
AM 1200 v capacity (%) - Ø400 mm
100
100
90
90
80
80
70
70
60
Right/left 35 dBA
40
Centre 30 dBA
30
Right/left 30 dBA
20
300
60
Centre 35 dBA
50
400
500
600
700
800
900
1000
1100
1200
1300
Centre 35 dBA
50
Right/left 35 dBA
40
Centre 30 dBA
30
20
300
Right/left 30 dBA
400
500
600
100
90
80
70
60
Centre 35 dBA
50
Right/left 35 dBA
40
Centre 30 dBA
30
Right/left 30 dBA
20
500
600
700
800
900
1000
1100
1200
1300
40
38
36
34
32
30
28
26
24
22
20
500
350
38
300
36
34
250
32
200
30
28
24
22
900
1300
600
700
800
1000
1100
1200
1300
1100
1200
1300
500
1400
70
60
50
120
Centre, 30 dBA
Right/left, 35 dBA
Right/left, 30 dBA
100
900
1000
1100
1200
1300
1400
900
1100
1200
1300
1100
1200
1300
1400
Centre, 35 dBA
Centre, 30 dBA
Right/left, 35 dBA
Right/left, 30 dBA
0
500
600
700
800
900
1000
1100
1200
1300
500
1400
600
700
800
900
1000
1100
1200
1300
1400
Airflow (m3/h)
AM 1200 v External pressure drop (Pa) – Ø315mm - fresh air
1000
1000
Roof cap Ø400 mm
Airflow (m3/h)
Vertical Ø400 mm
900
20
100
90
80
70
60
50
40
30
20
10
0
800
800
60
10
Horizontal
700
700
40
20
Vertical Ø315 mm
600
600
80
0
800
Centre, 30 dBA
Right/left, 35 dBA
Right/left, 30 dBA
140
Centre, 35 dBA
30
Centre
Right/left
700
Centre, 35 dBA
AM 1200 v External pressure drop (Pa) – Ø400 mm - exhaust
40
600
Wall grille
Airflow (m3/h)
Roof cap Ø400 mm
AM 1200 v External pressure drop (Pa) – Ø315mm - exhaust
140
Roof cap Ø315 mm
Centre, 35 dBA
120
Centre, 30 dBA
Right/left, 35 dBA
Right/left, 30 dBA
100
Roof cap Ø315 mm
Centre, 35 dBA
Centre, 30 dBA
Right/left, 35 dBA
Right/left, 30 dBA
80
60
40
20
500
600
Airflow (m3/h)
AM 1200 SFP W/(m3/s)
1000
90
50
1400
900
AM 1200 v External pressure drop (Pa) – Ø400 mm -fresh air
100
0
500
100
90
80
70
60
50
40
30
20
10
0
Airflow (m3/h)
80
Airflow (m3/h)
1000
900
800
700
600
500
400
300
200
100
0
500
1200
150
Ø315 mm centre
Ø315 mm right/left
Ø400 mm centre
Ø400 mm right/left
26
800
1100
AM 1200 Power consumption (W)
40
700
1000
Airflow (m3/h)
AM 1200 v Sound pressure level (dB(A))
600
900
AM 1200 h External pressure drop (Pa) – exhaust air
Wall grille
Centre, 35 dBA
Centre, 30 dBA
Right/left, 35 dBA
Right/left, 30 dBA
100
Airflow (m3/h)
20
500
800
AM 1200 h Sound pressure level (dB(A))
AM 1200 v capacity (%) - Ø315 mm
400
700
120
110
100
90
80
70
60
50
40
30
20
10
0
500
Airflow (m3/h)
Airflow (m3/h)
300
AM 1200 h External pressure drop (Pa) – fresh air
product information am 1200
AM 1200 h capacity (%)
700
800
900
1000
1100
1200
1300
0
500
1400
600
700
800
900
1000
1100
1200
1300
1400
Airflow (m3/h)
Airflow (m3/h)
AM 1200 Temperature efficiency (%)
88
87
AM 1200 Throw (0.15 m/s)
86
0m
85
Vertical Ø315 mm
Horizontal
Vertical Ø400 mm
600
700
800
900
Airflow (m3/h)
1000
1100
1200
1300
11m
1
84
83
82
500
600
700
800
900
1000
1100
1200
1300 m3/h
Max.
Min.
1000 m3/h
Max.
Min.
1300
Airflow (m3/h)
AM 1200
The Airmaster units provide different air throw lengths depending on
supply air volume. The blue tones
on the illustration on the left show
the airflow at different throws.
AM 1200
2
70
1
2
Throw viewed from above
Throw viewed from the side
71
AM 1200 h (horizontal) - right
product information am 1200
AM 1200 h (horizontal) - centre
AM 1200 h (horizontal) - left
72
73
AM 1200 V (vertical) - right
AM 1200 V (vertical) - left
AM 1200 roof cap unit Ø315
product information am 1200
AM 1200 V (vertical) - Centre
A panel box is available for the roof cover module to cover intake and exhaust. White as standard.
74
75