Water sustainabliity and the Caboolture ShirePlan
Transcription
Water sustainabliity and the Caboolture ShirePlan
Water sustainability and the Caboolture ShirePlan Background The Caboolture ShirePlan includes a number of provisions that contribute to an overall improvement of water use within the district. The basic premise of these provisions is that every opportunity should be sought to collect rainwater and reuse that water throughout a site either within a building or on outdoor areas. Rainwater tanks Through the Caboolture ShirePlan, council has incorporated water sustainability across the range of Class 1 – 9 buildings and identifies the circumstances for when a rainwater tank is required, as referenced in Table 1 below. The Water Sustainability Code is included as a development code in Part 7 of the ShirePlan. The code is also set out so it operates for self assessment. Part 4 Assessment Tables identifies when it is an applicable code for development. For extensions or additions involving a new roof area greater than or equal to 100m 2, the rainwater tank will only need to be connected to an external tap and/or a swimming pool and not to any internal plumbing fixtures. Dual reticulation A provision is included in the general works code requiring the provision of dual reticulation for development. Dual reticulation comprises two water pipes servicing an area or site. Pipe 1 contains potable water. Pipe 2 contains highly treated recycled water for use in toilets and for external purposes such as the watering of gardens and is not for drinking purposes. Such a system has significant water saving potential. In the short term, not all sites will be connected to a dual reticulated system but there is merit in requiring new development to provide for this in the likely event that such a network will be made available in the future. Page 1 of 2 March 14 Table 1 - Summary Table for Rainwater Tank and Plumbing Connection Requirements Use Dwelling houses Other residential uses (accommodation building, dependent person’s accommodation, dual occupancy, multiple dwelling, retirement village, and special care facility) Other uses (e.g. commercial and industrial) Criteria Requirement For extensions or additions involving a new roof area greater than or equal to 100m2 ShirePlan applies – provide a 3000 litre rainwater tank and connect to external tap and swimming pool only For extensions or additions involving a new roof area less than 100m2 For a new use and involving a class 2 component No requirement for a rainwater tank or connection For all classes, for extensions or additions involving a new roof area greater than or equal to 100m2 For extensions or additions involving a new roof area less than 100m2 ShirePlan applies – provide a rainwater tank and connect to external tap and swimming pool only No requirement for a rainwater tank or connection For extensions or additions involving a new roof area greater than or equal to 100m2 ShirePlan applies – provide a rainwater tank and connect to external tap and swimming pool only For extensions or additions involving a new roof area less than 100m2 No requirement for a rainwater tank or connection Page 2 of 2 ShirePlan applies – provide a rainwater tank and connect to internal and external plumbing, and a swimming pool. March 14