Power Generation & Substation
Power Substation Solutions
Project Introduction
Power T&D was acquired by Alstom of
France in October of 2010. Alstom and
Schneider Electric combined forces
and worked as joint-solution providers
for the country’s electrical transmission
and distribution systems. The two
companies provided solutions that
lrt the company to bring electricity
from the generating site to the
distribution network. They built both
high and medium voltage substations,
and the infrastructure required to
fully manage digital substations.
One example is Project Power This is a
main substation located in the City
of Tejar, Mexico. The installation
group chose Kyland-USA IEC61850
Ethernet products. The KY-3000EM
switch was used to provide a high
reliability backbone that was used
to manage the digital substation.
The switches are used as both a
backbone and access switch for the
substation. High reliability and
High Security Ethernet is why the
Kylan-USA product was chosen.
Kyland-USA
Network Security for the 21st Century
Company: Areva T&D
Location: City of Tejar, Costa Rica
Kyland-USA
System Requirements
DYMEC
IEC61850 compliant products
Real time transmission of GOOSE/GSSE packets
Resistant to harsh substation environments: strong EMI, extreme temperature variation, high
surge, etc
Kyland-USA Solution / DYMEC Solution
criteria for EMI immunity. Areva T&D chose Kyland-USA products to construct a rugged substation
backbone because Kyland-USA has the best IEC61850-3 & IEEE1613 & high security products in
the energy and utility markets.
The KY-3000EM Series are industrially hardened, fully managed Ethernet switches,
utility substation and industrial environments. They support QoS and fast store and
forwarding mode to ensure the real time transmission of GOOSE/GSSE packets, along with
supporting VLAN for segment isolation to guarantee the real time, and reliable transmission
of important data. They work in a wide temperature range of -40 to 80°C (-40 to 176°F) with
a protection class of IP40.
Kyland-USA’s KY-3000 Series are deployed in this project to connect all of the the SEL
the event of network failure.
DYMEC Serial Links were used as isolation communicators for serial RTU’s and other
legacy serial support applications
Kyland-USA
Generic System Diagram
CENCE IEC
870-5-101
SE EL
BOSQUE
Modulo de Alarmas Generales P1
GPS SEL 2407
SBDS
P1
SBDS
P1
UCS SMP-16
SEL 451-4
0
KY-3000EM
1
3
S KY-3000EM
TP5
SEL 421
KY-3000EM
TP2
SEL 421
TC1
SEL 451-4
KY-3000EM
SKY-3000EM
KY-3000EM
TC2
KY-3000EM
TP3
TP6
TP1
SEL 387E
SEL 387E
SEL 451-2
SEL 451-2
SEL 352-
SEL 352-1
SEL 451-4
SEL 487B
SEL 421
SEL 421
SEL 451-4
KY-3000EM
SEL 451-4
TP4
Extremo Linea
Solo suministro
SEL 421
Extremo Linea
Solo suministro
SEL 421
TCP
ATR1
TAPCON 230
SEL 451-4
ATR2
TAPCON 230
SEL 487B
SEL 451-4
CANBUS
SEL 2411
TP Cable
F/O Cable
KY-3000EM
Why Kyland-USA?
KY-3000EM
2 Gigabit SFP slots, 8 10/100Base-TX
EMC design meets the requirements as
in the IEC61850 standard.
optional ports
Supports -Ring protocols, RSTP and
MSTP
Supports GMRP, DHCP, SNMP, QoS
SNMPv3, HTTPS, SSH/SSL enhance
Supports VLAN, QoS functions to
guarantee the real time transmission of
important data with zero packet loss.
Redundant ring network with fast recovery
time to increase network reliability.
Operating temperature is -40 to 80°C (-40
to 176°F) .
Kyland-USA
Network Security for the 21st Century
Please refer to www.Kyland-USA.com for more details