the catalogue
Transcription
the catalogue
ECOFIT Medium & Low Voltage Distribution Modernisation of switchboards Catalogue 2016 schneider-electric.com/electricaldistributionservices ™ Standard solutions Index Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 1 Medium Voltage ECOFIT™ standard solutions How to find an ECOFIT™ solution? 1 2 Select the " generic family ". Original Brand 1 MV CB or Contactor or 3 Select the " Panel type ". MV Panel MV Cradle Panel type 2 3 Select the " Original device type ". Original device type New device type Flyer SERED N° Page to Cradle Disconnector Square D ✓ 5-15 kV MC switchgear VAD2-3 Magnum CB 111036EN A-2 ✓ AHA ECA HVX-O2 111168EN A-3 Other brand ✓ All with fixed CB All fixed CB types HVXUW 111102EN A-4 Alsthom ✓ Alliance FP - GFA FP - GFA 111122EN A-5 Merlin Gerin ✓ Belledonne B200-B400 DSE22 to DSE78 LF2 - LF3 - SF1 - Evolis 111009EN A-6 Merlin Gerin ✓ Belledonne B200G DSE22K-DSE23K LF1 - Evolis 111010EN A-7 Merlin Gerin ✓ Belledonne B650 DIS LF1 - R400 - R400D - Evolis 111007EN A-8 Merlin Gerin ✓ Belledonne B900 DIS SF1 111008EN A-9 ✓ BVP 17 BVP 17 VMX 111060EN A-10 CB FP 111026EN A-11 CS - CX - FPR FPR 111028EN A-12 AEG, Alsthom, Alstom AEI, GEC Alsthom CEM ✓ CEM ✓ Nuova Magrini CemablocC23mc 15 & 27 CemablocC26.0 ✓ Composit MG SF1 111048EN A-13 ✓ CSIM 1-12 SCI-4 VEIVACUUM F 111044EN A-14 ✓ CSIM 3-12 SCI-4 VEIVACUUM F - VA 111073EN A-15 Alsthom ✓ DNF4-2E FP - GFA FP - HVX - CVX 111088EN A-16 Alsthom ✓ DNF4 MI&FI FP FP - HVX 111089EN A-17 Alsthom ✓ DNF5/DNF5-2B FP FP - HVX 111092EN A-18 Alsthom ✓ DNF6 FP FP - HVX 111093EN A-19 Alsthom ✓ DNF7 FP FP - HVX-O2 111090EN A-20 ✓ Epoclad DHF -F LF1 - LF2 - LF3 - SF1 111049EN A-21 Merlin Gerin ✓ Fluair F100-F200 FG1 - FG2 LF2 - LF3 - Evolis 111012EN A-22 Merlin Gerin ✓ Fluair F100C R400-R400D R400 - R400D 111013EN A-23 Merlin Gerin ✓ Fluair F300 FG3 SF1 - SF2 111101EN A-24 Merlin Gerin ✓ Fluair F400C FC4 SF2 111014EN A-25 Merlin Gerin ✓ Fluair F400G FG4 SF1 - SF2 111015EN A-26 ✓ Fluokit M24 FP FP 111138EN A-27 ✓ Fluokit M24 + FP FP 111141EN A-28 ✓ Fluokit M36 FP FP 111136EN A-29 ✓ GS-10 111041EN A-30 111061EN A-31 Galileo VEB Otto Buchwitz VEB Otto Buchwitz Nuova Magrini Galileo GEC, GEC Alstom, Alstom GEC, GEC Alstom, Alstom GEC, GEC Alstom, Alstom AEG GE VA - VAA HMC 400 - HMC 400 - HMC 410 HMC 410 GEC Alstom ✓ HMC 400 & HMC 410 GEC Alstom ✓ HMC 1072 HMC 1072 HMC 1072 111062EN A-32 GEC Alstom ✓ HMC 1172 HMC 1172 HMC 1172 111063EN A-33 GEC Alstom ✓ HMX 36 HMX 36 HMX36 111064EN A-34 ✓ HP HP-W-TW-TM HVX 111078EN A-35 ✓ HWX HWX HWX 111166EN A-36 Concordia Sprecher GEC, GEC Alsthom, Alstom, NEW NEW Areva 2 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 1 Original Brand MV CB or 2 MV Panel MV Cradle Panel type 3 Original device type New device type Flyer SERED N° Page to Cradle Contactor or Disconnector GOST standard ✓ K104 K104 LF1 - Evolis 111164EN A-37 NEW ✓ KAD KAD VMX-540 111162EN A-38 NEW GOST standard ✓ KRU 2-10 KRU 2-10 LF1 - Evolis 111165EN A-39 NEW Merlin Gerin ✓ MC500 SF1T SF1T 111156EN A-40 NEW Federal Pioneer ✓ Metalclad switchgear DST 2 & 5 DST 2V & 5V 111067EN A-41 Merlin Gerin ✓ Motorstart P50D C - CD R400 - R400D - CTV1 111005EN A-42 GEC, GEC Alsthom, Alstom Merlin Gerin ✓ Motorstart P500D C1 - CD1 R400 - R400D - CTV1 111006EN A-43 GEC Alstom ✓ MX 51 & MX 81 MX 51 - MX 81 MX 51 - MX 81 111065EN A-44 Delle Alsthom ✓ Normabloc N1347 HL HVX - FPX 111033EN A-45 ✓ Normaclad PX FPX FPX 111139EN A-46 ✓ PX 12 - 24 FPX FPX 111124EN A-47 ✓ PIX SF6 FPX FPX 111137EN A-48 ✓ PNX 36 HVX 36 HVX 36 111127EN A-49 VA - VAA - Contactor 111042EN A-50 GEC, GEC Alstom, Alstom Alsthom GEC, GEC Alstom, Alstom AEG IMC - MC - FAL - IFAL - VA AEG R ✓ - VAA - IVA - BAL - ALF AL - TG GOST standard ✓ RSW RSW LF1 - Evolis 111163EN A-51 Ansaldo ✓ Siclad MAG II LF1 - LF2 111050EN A-52 Square D ✓ DSE Magnum CB 111037EN A-53 Nuova Magrini Solenarc DSE Metal-Clad switchgear ✓ Venus GI-GL LF1-LF3 111051EN A-54 ✓ VISAX BLV BLV 111140EN A-55 ✓ VM6 DM12 FB4 SF1 111018EN A-56 ✓ VMX VMX VMX 111154EN A-57 AEG ✓ WBA VA - VAA - ECA - BAL - AL VA - VAA - Contactor 111082EN A-58 AEG ✓ WBB VA - VAA - ECA - BAL - AL VA - VAA - Contactor 111084EN A-59 AEG ✓ WBD VA - VAA - HVX VA - VAA 111129EN A-60 AEG ✓ WK (C/E/B/A) VA - MC - BAL VA - VAA - Contactor 111086EN A-61 ✓ YSF6 YSF6 YSF6 Evolis 111066EN A-62 ✓ AHA AHA panel AHA panel 111167EN A-63 ✓ DNF7 DNF7 panel DNF7 panel 111100EN A-64 Galileo GEC, GEC Alsthom, Alstom Merlin Gerin GEC, GEC Alsthom, Alstom Yorkshire Switchgear AEG, Alsthom, Areva Alsthom Merlin Gerin ✓ F100/200 F100/200 panel F100/200 panel 111071EN A-65 Alstom ✓ PIX SF6 PIX SF6 panel PIX SF6 panel 111157EN A-66 Areva ✓ PNX36 PNX36 panel PNX36 panel 111126EN A-67 Alstom ✓ PX 12-24 PX 12-24 panel PX 12-24 panel 111091EN A-68 AEG ✓ R R panel R panel 111079EN A-69 GEC Alstom ✓ VISAX VISAX panel VISAX panel 111123EN A-70 ✓ VMX VMX panel VMX panel 111097EN A-71 AEG ✓ WBA WBA panel WBA panel 111081EN A-72 AEG ✓ WBB WBB panel WBB panel 111083EN A-73 AEG ✓ WBD WBD panel WBD panel 111128EN A-74 AEG ✓ GEC, GEC Alstom, Alstom WK WK panel WK panel 111085EN A-75 Other brand ✓ All All breaker types Evolis MC Cassette 111105EN A-76 Other brand ✓ All All breaker types F400 Cassette 111106EN A-77 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 NEW NEW NEW 3 Low Voltage ECOFIT™ standard solutions How to find an ECOFIT™ solution? 1 2 Select the " generic family ". Original Brand 1 LV CB or LV Drawer Select the " Panel type ". Panel type 2 3 3 Select the " Original device type ". Original device type New device type Flyer SERED N° Page Contactor Nuova Magrini Galileo ✓ NA B Control Masterpact NW 111053EN B-2 Merlin Gerin ✓ NA Compact C801-C1251 Compact NS 111022EN B-3 Merlin Gerin ✓ NA DA Masterpact NW 111019EN B-4 Square D ✓ NA DS Masterpact NW 111038EN B-5 Federal Pioneer ✓ NA H series Masterpact NT - NW 111068EN B-6 Merlin Gerin ✓ NA Masterpact M Masterpact NW 111021EN B-7 ✓ NA SE Masterpact NW 111039EN B-8 Merlin Gerin ✓ NA Selpact Masterpact NT - NW 111020EN B-9 Unelec-Areva ✓ Normabloc 660 Unelec CNP Masterpact NW 111023EN B-10 Merlin Gerin ✓ NA Visucompact CM Masterpact NW 111024EN B-11 Square D, Westinghouse Merlin Gerin ✓ T140 T140 drawers T140 drawers 111094EN B-13 Merlin Gerin ✓ MB400 MB400 drawers MB400 drawers 111095EN B-14 4 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Protection relays ECOFIT™ standard solutions How to find an ECOFIT™ solution? 1 2 Select the " generic family ". 1 Original Brand Protection relay GE Select the " Panel type ". 2 3 Panel type ✓ 3 Select the " Original device type ". Original device type New device type Flyer SERED N° Page CO MiCOM P111/115 111131EN C-3 CDG - CAG - CTMM - MiCOM P1x-P2x CTMFM or Vamp 5x 111147EN C-4 Alstom ✓ ABB ✓ DPU 445 MiCOM P123 111134EN C-5 ABB ✓ HCB MiCOM P521 111133EN C-6 GE ✓ IAC MiCOM P122 111132EN C-7 GEC Alstom, Areva ✓ All KCGG 122 & 142 MiCOM P123R 111070EN C-8 Areva or older ✓ all / draw out MiCOM P120H 111104EN C-9 Areva or older ✓ all / draw out MiCOM P821MF 111103EN C-10 Alstom ✓ MCGG 62 MiCOM P126 111135EN C-11 Merlin Gerin ✓ All Sepam 2000 Sepam 60/80 111087EN C-12 Merlin Gerin ✓ RM6+ VIP VIP + ECOFIT™ kit 111046EN C-13 Merlin Gerin ✓ Various equipment VIP & Vigirex VIP & Sepam 111146EN C-14 M range MCGG 11, 21 & 22 M range relay MCTI 39-40 Substation automation ECOFIT™ standard solutions How to find an ECOFIT™ solution? 1 2 Select the " generic family ". Select the " Original device type ". 1. Original Brand 2. Control System Original device type New device type Ref. ECOFIT™ centre Flyer Page SERED N° AREVA or older ✓ AREVA or older ✓ AREVA or older ✓ ✓ Schneider Electric Bay Controler BM9x00 MiCOM C624 FR EAC Lattes* 111144EN D-3 PACiS EcoSUI FR EAC Lattes* 113543EN D-4 PSCN3020 HMI EcoSUI HMI FR EAC Lattes* 113562EN D-5 Seefox HMI EcoSUI HMI FR EAC Lattes* 111143EN D-6 PACIS OI (V3.x up to V4.6) * Not current ECOFIT™ reference centre Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 5 6 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Customised solutions Index Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 7 Medium Voltage ECOFIT™ customised solutions Those solutions have been manufactured and installed all over the world to answer specific customer request. Schneider Electric can help you to identify the right solution to modernise your installation, with a site visit if required. Original Brand ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB ABB AEG AEG AEG AEG ALIND Allis-Chalmers & Siemens-Allis Allis-Chalmers & Siemens-Allis Allis-Chalmers & Siemens-Allis Allis-Chalmers & Siemens-Allis Allis-Chalmers & Siemens-Allis ALSTHOM ALSTHOM ALSTOM ALSTOM ALSTOM ALSTOM / AREVA / Schneider Electric ALSTOM / AREVA / Schneider Electric ASEA CGL Calor Emag Calor Emag CONCORDIA SPRECHER CONCORDIA SPRECHER CONCORDIA SPRECHER CONCORDIA SPRECHER CONCORDIA SPRECHER DELLE DELLE DELLE DELLE DELLE DELLE DELLE DELLE DELLE DELLE DELLE DELLE DELLE DELLE DELLE DELLE EIB Federal Pacific Federal Pacific FUJI GEC General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric General Electric ITE 8 Panel type AIS AIS AIS AIS AIS AIS VHE800 VHE800 VHE950 AIS AIS AIS AIS AIS AIS AIS VHA-12S HA3zc FKCM4/24-2 FKCM5/12-2 FKEM4/24-2/721 FKEM4/24-2/723 AIS AIS AIS AIS AIS AIS NORMABLOC-DNL4 WBS GMA Version 1 NORMAFLUOR-DNF4 AHA Fluokit-M9 Fluokit-M9 VHE-800 AIS AIS AIS PIC-106 PID 104/105/106 SC - SD 204/206 SCC 204/206 SCD 204 NORMABLOC-DN6S NORMABLOC-DN6S NORMABLOC-DNL4 NORMABLOC-DNTL NORMABLOC-DNTC NORMABLOC-DNTG NORMABLOC-N142 NORMABLOC-N143 NORMABLOC-N340 NORMABLOC-N342 NORMABLOC-N1147 NORMABLOC-ND3 NORMABLOC-ND5 NORMASEPT-N740 NORMASEPT-N1742 FLUOMATIC-N962 Modulec CT 17.5 AIS AIS HF55 BVX AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS Original device type E7512/10 EKU5012/10 EKU5016/10 EKU5025/10 GR256 HB12-12-40 HKK12/1226 HKK12/1240 HKK12/3140 JVE301 MS 2 MS 3 MT1 MT2 OD1M S F ASG VRC GCB VA/VAA/LTRI/AL VA/VAA/LTRI/AL VA/VAA/LTRI/AL VA/VAA/LTRI/AL HL430 FA MA FB FC, MC FC HL VB6 GMA FP ECA VBL DPIL HKK SFG-40S OD3 OD4 HP HP HVTW(z) HPCTW HPDTW HG HL HK & HL HL CHT HL RA HK FJ RA HL HG or HK or HL HG HL RA SFC A DST-DST2 DST-DST2 OCB KAD AM AM AM AM AM-7.2 AM-13.8 Tall-Boy AM-4.16 AMH AMH-4.76 5-HV Un (kV) 10 10 10 10 12 24 12 12 12 12 12 12 12 12 12 12-16 7,2 12 24kV 12kV 24kV 24kV 12 4,16 4,16 7,2 &13,8 13,8 13,8 12 24 12 17,5 up to 17,5 12-17,5 12-17,5 12 7,2 12 12 12-24 12-24 12-24 12-24 12-24 24 24 12 12 7,2 7,2 17,5 17,5 23 23 12 7,2 17,5 24 24 7,2 12 to 24 4,16 13,8 7.2 12 4,16 4,16 7,2 13,8 7,2 13,8 4,16 4,76 4,76 4,16 In (A) 1250 1250 1600 2500 630 1600 1250 1250 2500 400 1250 1600 1250 1250 400 1250 to 2500 400 630 to 2500 up to 1250 up to 1250 up to 1250 up to 1250 1250 3000 1200, 2000 1200, 2000 1200, 2000, 3000 1200, 2000 2500 1250A 2000 2500 1250 630-1250 630-1250 1600 1250 630 to 1250 630 to 1250 up to 1600 up to 1600 up to 1600 up to 1600 up to 1600 2500 1250 2500 1250 200 3200 400 630 400 200 1250 1250 1250 400 200 400 630 - 1250 1200, 2000,3000 1200, 2000 600A 400 to 1250 400 1200, 2000,3000 1200, 2000, 3000 1200, 2000 1200, 2000, 3000 3000 600, 1200 1200, 2000 1200, 2000 1200, 2000 Isc (kA) 40 50 50 50 13,1 25 26,3 40 40 40 40 40 26,3 26,3 26,3 26-40 25 40 up to 25 up to 25 up to 25 up to 25 40 41 40 & 50 18 18 - 28 37 40 25KA 25 25 31,5 up to 25 up to 25 40 31,5 31.5 31.5 up to 25 up to 25 up to 25 up to 25 up to 25 25 25 40 40 25 40 25 16 12,5 12,5 40 12,5 12,5 14,5 16 12,5 up to 25 29-41 18-28 25KA up to 20 Fused 40 33 18 up to 37 33 37 20 29 29 29 to 40 New device type HWX HWX HWX HWX HWX Evolis HWX HWX HWX HWX HWX HWX HWX HWX HWX HWX LF LF VA/VAA VA/VAA VA/VAA VA/VAA HWX Magnum Magnum Magnum Magnum Magnum FPX HVX-O2 GMA Version 2 HVX HVXO² Evolis or SF1 SFset Evolis Rollarc Evolis Evolis HVX HVX HVX HVX HVX FP FP HVX FPX GFA FP GFA or FP FP FP FP FPX FP FP FP FP GFA SF/HVX Magnum Magnum Evolis VMX Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage ECOFIT™ customised solutions Those solutions have been manufactured and installed all over the world to answer specific customer request. Schneider Electric technician will require a visit to customer premises to validate the solution. Original Brand ITE / ABB ITE / ABB ITE / ABB JYOTI LG McGraw McGraw Merlin Gerin Merlin Gerin / Lorenzetti Inebrasa Merlin Gerin / Lorenzetti Inebrasa Merlin Gerin / Lorenzetti Inebrasa Merlin Gerin / Lorenzetti Inebrasa Merlin Gerin / Lorenzetti Inebrasa Mitsubishi Mitsubishi NGEF NGEF NGEF NGEF NGEF NGEF NGEF NGEF NGEF NGEF NISSIN NMG SACE SIEMENS SIEMENS SIEMENS SIEMENS SIEMENS SIEMENS Square D Square D Square D Square D Square D Square D Square D Square D Square D VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS VOLTAS Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Westinghouse Panel type AIS AIS AIS AIS AIS AIS AIS V23-60 Flurin Lorin Flurin CCM III CCM II AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS 8BD1 8BD1 AIS AIS 8BD1 8BD1 AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS AIS Original device type 5-HK 7.5-HK 15-HK MT2-1208-20 GVB PSD WSA DIS23-D3 FG1 FG1, FG2 FG2 VC TOYO C1 VF/ FM 6 DHE 32 M E7512 E7525 EKU5012 EKU5016 EKU5025 EKU5025 EKU5025/10 EKU-GR256 EKU 5012/10 GR256 VSR 10 MG 500 D6 3AC 3AC H512/H515 3TL / 1BF 3AC CB DSE DSE23 DSE25 DSE-65 DSE-68 VAD2 VAD2 VAD3 VAD3 BMTT BE BEC BMTT FB4 FB4 FB4 Kiosk FG2 FG2 FG2 FG2 FG2 FP GHM HF HKK HKO HL 50-DH 75-DH 150-DH 150-DH 50-DH 50-DHP 75-DHP 75-DHP 150-DHP 150-DHP 5WYB 8WYB 15WYB 15WYB Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Un (kV) 4,16 7,2 13,8 12 7.2 13,8 13,8 24kV 17,5 17,5 17,5 7.2 7,2 12 4.76 12 12 12 12 7,2 12 10 12 6.6 12 7.2 7.2 17,5 7,2 12 12 7.2 7.2 7.2 4,16 4,16 4,16 13,8 13,8 4,16 13,8 4,16 13,8 12 12 12 12 24 36 22 12 7,2 7,2 12 12 12 12 12 12 12 12 4,16 7,2 13,8 13,8 4,16 4,16 7,2 7,2 13,8 13,8 4,16 7,2 13,8 13,8 In (A) 1200, 2000, 3000 1200, 2000 1200, 2000, 3000 1250 630 1200, 2000 1200, 2000 630A 1250 1250 1250 400 400 1250A 1200 to 2000 1600 1250 2500 2500 2500 1250 2500 1250 1250A 1250 400A 630A 1250 630 1250 to 2500 1250 450 630 to 2000 630 to 2000 1200 2000 3000 1200 3000 1200 1200, 3000 1200, 2000 1200, 2000 1250 1250 1250 1250 2000 1250 630 1250 2000,2500,3150 1250 1250 1250 1250 1250 1250 1250 1250 1250 1200, 2000 1200, 2000 1200, 2000 1200, 2000, 3000 1200, 2000 1200, 2000, 3000 1200, 2000, 3000 320 1200, 2000 3000 1200, 2000, 3000 1200, 2000, 3000 1200, 2000 3000 Isc (kA) 40 to 50 33 18 to 37 25 31.5 18 18 25 25 25 25 50 50 31.5 29 25 40 40 40 40 40 50 31,5 30.6 31,5 4 25 25 40 40 31,5 6 25 40 29 29 41 up to 28 37 up to 41 37 up to 41 up to 28 26,3 40 40 40 25 25 25 40 40 31,5/ 40 40 40 40 40 40 40 40 40 29 / 41 33 18 / 28 37 29 / 41 41 33 Fused 18 / 28 33 41 33 18 / 28 33 New device type Magnum Magnum Magnum Evolis Evolis Magnum Magnum SF LF LF LF Rollarc Rollarc Evolis LF Evolis Evolis Evolis Evolis Evolis Evolis Evolis Evolis Evolis Evolis CTV LF LF Evolis HWX Evolis CVX Evolis Evolis Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum HWX HWX HWX HWX Evolis SF Evolis Evolis or LF Evolis or LF Evolis or LF Evolis or LF HWX HWX Evolis Evolis HWX HWX Evolis Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum Magnum 9 Low Voltage ECOFIT™ customised solutions Those solutions have been manufactured and installed all over the world to answer specific customer request. Schneider Electric technician will require a visit to customer premises to validate the solution. Original Brand Range Original device type In (A) New device type Allis Chalmers LA-600 / LA-800 LASB1-D2 800 Masterpact NT Allis Chalmers LAF-600 / LAF-800 LASB2-D2 800 Masterpact NT Allis Chalmers LAF-800 LASB2 800 Masterpact NT Allis Chalmers LA-1600 LASB3 1600 Masterpact NW ASEA/ABB VMG ALG08 800 Masterpact NT ASEA/ABB VMG ALG12 1250 Masterpact NT ASEA/ABB VMG ALG16 1600 Masterpact NT ASEA/ABB VMG ALG20 2000 Masterpact NW ASEA/ABB VMG ALG25 2500 Masterpact NW ASEA/ABB VMG ALG32 3200 Masterpact NW Federal Pacific FM-600 Fused LFSB9 600 Masterpact NW Federal Pacific FM-1600 Fused LFSB8 1600 Masterpact NW Federal Pacific FP-25 / FPS-25 LFSB4 800 Masterpact NT Federal Pacific FPS-30 LFSB7 800 Masterpact NW Federal Pacific FP-50 LSFB5 1600 Masterpact NW Federal Pacific FP-50-H3, 14" Frame (IEC) SE Can 800 Masterpact NT Federal Pacific FP-50-H3, 21" Frame (ANSI) SE Can 800 Masterpact NW Federal Pacific FP-50-H3, 21" Frame (IEC & ANSI) SE Can 2000 Masterpact NW Federal Pacific FP-75 LFSB6 3200 Masterpact NW Federal Pioneer 25HL-2 SE Can 800 Masterpact NT Federal Pioneer 25HL-2 SE Can 600 Masterpact NT Federal Pioneer 35HL-2 LFSB1 800 Masterpact NW Federal Pioneer 50HL-2 SE Can 1600 Masterpact NW Federal Pioneer 65HL-2 SE Can 2000 Masterpact NW Federal Pioneer 75HL-2 SE Can 3000 Masterpact NW General Electric AE-1B (M.O.) LGSB18 800 Masterpact NT General Electric AK-(1/2/3/4/5)-15/25 LGSB6 800 Masterpact NT General Electric AK-(2A/3A/4A/5A)-15/25 LGSB1/7/11 800 Masterpact NT General Electric AK-(1/2/3/4/5)-50 LGSB10 1600 Masterpact NW General Electric AK-(2A/3A/4A/5A)-50 LGSB4 1600 Masterpact NW General Electric AKR-30 (AKD-6 swgr) LGSB2D 800 Masterpact NW General Electric AKR-30 (AKD-6 swgr) LGSB13 800 Masterpact NT General Electric AKR-30 DC LGSB5 800 Masterpact NW General Electric AKR-30 (Powell swgr) LGSB8 800 Masterpact NT General Electric AKR/AKRT-30 (AKD-8 swgr) LGSB2C 800 Masterpact NW General Electric AKR with Contactor LGSC2 540 Masterpact General Electric AKRU-30 (1 Position) LGSB14 800 Masterpact NW General Electric AKR-50 (AKD-6 swgr) LGSB2 1600 Masterpact NW General Electric AKR/AKRT-50 (AKD-8 swgr) LGSB2C 1600 - 2000 Masterpact NW General Electric AKR-50 (Powell swgr) LGSB9/9A 2000 Masterpact NW General Electric AKR-50 DC (Hatch swgr) LGSB22 2000 Masterpact NW General Electric AKRU-50 (1 Position) LGSB17 1600 Masterpact NW General Electric AKR-75 (3 Pos./Ver. Bus) LGSB12 3200 Masterpact NW General Electric AL-2-50 (M.O.) LGSB19 1600 Masterpact NW ITE / ABB / BBC K-225 LISB9 225 Masterpact NT ITE / ABB / BBC K-600 / K-800 LISBA1 800 Masterpact NT ITE / ABB / BBC K-600 / K-800 with MOC/TOC LISB8 800 Masterpact NT ITE / ABB / BBC K-Don 600/800 LISB11 800 Masterpact NT ITE / ABB / BBC K-Don 1600 LISB12 1600 Masterpact NW ITE / ABB / BBC K-1600 / K-1600S LISB2 1600 Masterpact NW ITE / ABB / BBC K-2000 / K-2000S with TOC LISB5 2000 Masterpact NW ITE / ABB / BBC KB LISB3 600 Masterpact NT ITE / ABB / BBC KC LISB4 1600 Masterpact NW ITE / ABB / BBC MB-8 / MBE-8 LBSB1 800 Masterpact NT ITE / ABB / BBC MB-16 / MBE-16 LBSB2 1600 Masterpact NW ITE / ABB / BBC LKE-8 LISB6 800 Masterpact NT KAFAK KAFAK SFBY 250 Compact NSX KAFAK KAFAK SFBY 630 Compact NSX Merlin Gerin Compact CM CM 1250 3P Fixed Front 1250 Compact NS Merlin Gerin Compact CM CM 1600 4P HH Fixed 1600 Masterpact NW Merlin Gerin Interpact IN IN2500A 3P Fixed 2500 Interpact INS 10 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Low Voltage ECOFIT™ customised solutions Those solutions have been manufactured and installed all over the world to answer specific customer request. Schneider Electric technician will require a visit to customer premises to validate the solution. Original Brand Range Original device type In (A) New device type Siemens SBS 1200 1200 Masterpact NT Siemens SBS 800 800 Masterpact NT Square D MP-08 / MP-16 LSSB2 800 - 1600 Masterpact NW Square D MP-20 LSSB3 2000 Masterpact NW Square D MP-25 / MP-30 LSSB4 2500 - 3000 Masterpact NW Square D SED LSSB1 800 - 3000 Masterpact NW Square D SEM (SED-M) LSS5B 800 - 2000 Masterpact NW Square D DS-206 LWSB7 800 Masterpact NT Square D DS-206H LWSB9 800 Masterpact NW Square D DS-206E LWSB9 800 Masterpact NW Square D DS-416 LWSB9 1600 Masterpact NW Square D DS-416S LWSB9 1600 Masterpact NW Square D DS-416H LWSB9 1600 Masterpact NW Square D DS-420 LWSB9 2000 Masterpact NW Square D DSII-308 LWSB8 800 Masterpact NW Square D DSII-508 LWSB8 800 Masterpact NW Square D DSII-608 LWSB8 800 Masterpact NW Square D DSII-516 LWSB8 1600 Masterpact NW Square D DSII-616 LWSB8 1600 Masterpact NW Square D DSII-620 LWSB8 2000 Masterpact NW Westinghouse / Cutler Hammer / Eaton DB-15 Three Position (in DB-25 cell) LWSB6 225 Masterpact NT Westinghouse / Cutler Hammer / Eaton DB-25 Three Position LWSB1 800 Masterpact NT Westinghouse / Cutler Hammer / Eaton DB-25 Single Position LWSB5 800 Masterpact NT Westinghouse / Cutler Hammer / Eaton DBL-25 Three Position LWSB2 800 Masterpact NT Westinghouse / Cutler Hammer / Eaton DB-50 Single Position LWSB4 1600 Masterpact NW Westinghouse / Cutler Hammer / Eaton DB-50 Three Position LWSB3 1600 Masterpact NW Westinghouse / Cutler Hammer / Eaton DS-206 LWSB7 800 Masterpact NT Westinghouse / Cutler Hammer / Eaton DS-206H LWSB9 800 Masterpact NW Westinghouse / Cutler Hammer / Eaton DS-206E LWSB9 800 Masterpact NW Westinghouse / Cutler Hammer / Eaton DS-416 LWSB9 1600 Masterpact NW Westinghouse / Cutler Hammer / Eaton DS-416S LWSB9 1600 Masterpact NW Westinghouse / Cutler Hammer / Eaton DS-416H LWSB9 1600 Masterpact NW Westinghouse / Cutler Hammer / Eaton DS-420 LWSB9 2000 Masterpact NW Westinghouse / Cutler Hammer / Eaton DSII-308 LWSB8 800 Masterpact NW Westinghouse / Cutler Hammer / Eaton DSII-508 LWSB8 800 Masterpact NW Westinghouse / Cutler Hammer / Eaton DSII-608 LWSB8 800 Masterpact NW Westinghouse / Cutler Hammer / Eaton DSII-516 LWSB8 1600 Masterpact NW Westinghouse / Cutler Hammer / Eaton DSII-616 LWSB8 1600 Masterpact NW Westinghouse / Cutler Hammer / Eaton DSII-620 LWSB8 2000 Masterpact NW Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 11 Contents 12 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 ECOFITTM Contents Medium Voltage Distribution A-1 Low Voltage Distribution B-1 Protection relays C-1 Substation automation D-1 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 13 ew n e R How do I operate and maintain? Op e ra How do I install and commission? a ll How do I optimize? st Asset Management Life Cycle In Optimize What are my options? n Pla How do I renew my solution? te What does Renew mean? 14 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Schneider Electric is helping you to get the most of your equipment and installations Schneider Electric helps you define and implement the best solution evolvement, increasing performance and flexibility, while controlling aging infrastructures associated costs. Keeping Masterpact M original craddle Adapted Masterpact NW Masterpact M ECOFITTM is the economical complement to maintenance operations Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 15 For which benefits? 16 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 There are two main possibilities when considering modernization The first one would be to completely replace existing electrical installation with new equipments. This solution might not be the most cost effective. The second option would be to replace only active components, while leaving switchgear structure intact. Retrofit or retrofitting is the general term that is used to define this process. Several different retrofit solutions exist for adapting modern circuit breakers into existing switchgear. COSTS 2 to 6 days From few minutes to 1 hour New equipment Retrofit Cost of process downtime Material cost Site work cost A retrofit approach offers cost advantages in three important areas: •materials, •lost production time, •site preparation. • Enhances your process dependability. • Optimizes your maintenance service costs & limits your investments. • Maintains compliance with evolving industry standards and legislation. • Ensures the safety of your personnel and surrounding equipment by using the latest technology. • Access to Energy Management. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 17 Modernization solutions 18 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 The main advantages of implementing a retrofit solution Optimisation of assets The life of existing electrical equipment is extended thereby increasing the return on investment. Reduced production stoppage A retrofit full panel replacement will take anywhere from only a few minutes to one hour. When considering whether to maintain equipment or replace it, facility managers must take into account the initial capital cost, along with potential disruption to the facility’s processes and workflow during the course of changing out the equipment. Unless process loads can be rerouted temporarily during the demolition of old equipment and installation of the new switchgear, the cost of lost production can be substantial. Improved cash flow A full retrofit of an industrial site could spread over several years. Oftentimes, when new equipment is purchased, the on-site physical plant also needs to be modified to accommodate the new equipment, which adds to the cost. Reduced risk Installing new switchgear involves more cabling (requires that existing cabling above and below the equipment be moved). In some cases, cabling may need to be replaced or spliced, which introduces a higher element of risk. Peace of Mind Pre-tested solutions from established manufacturers provide a high degree confidence in a retrofit solution. Established players like Schneider Electric have managed thousands of switchgear retrofit projects and have an extensive library of lessons learned. Qualified personnel and up-to-date tools reduce the risk of accidents and delays. Accompanying safety improvements and updated warranties also contribute to overall power network peace of mind. Digitization Retrofit solutions also open the door to enhanced equipment connectivity. This then allows access to more detailed levels of energy management date which enables better monitoring of energy consumption. Less environmental impact Since a retrofit solution replaces only a portion of the existing electrical equipment, fewer waste materials need to be processed than if a complete replacement were to occur. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 19 Why modernize? 20 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Electrical Distribution equipment obsolescence and limited availability of spare parts The only solution to extend Electrical Distribution (ED) equipment life cycle is by carrying out an intense maintenance while planning a modernisation solution thanks to ECOFIT solution. There are three major phases in the product life cycle: 1. Commercialisation period: The product is launched onto the market and is included in the Schneider Electric catalogue. 2. Full spare parts availability period: The product is withdrawn from the market. Schneider Electric continues to supply spare parts for a period of time. Generally speaking, the average full spare part supply period after the end of commercialisation is : • Medium Voltage equipment: 12 years. • Low Voltage equipment: 10 years. When the end of the full spare part supply date is reached, the product is considered as at the end of its life. Maintennance costs 3. Modernisation period with ECOFIT™ solution: When spare parts are no longer readily available, the continuity of service and support is at risk. If a device breaks down, no parts may be available to fix it. At this stage, launching ECOFIT solution is recommanded. Corrective, Preventive Maintenance and spare parts guaranteed Modernisation Installation & commissioning End of commercialisation End of full spare parts availability End of spare parts Product life End of Services ECOFIT™ spare parts Schneider Electric provides spare parts or subassembly replacement associated to supplied ECOFIT equipments in order to ensure continuity of service. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 21 ECOFIT reference centers ™ 22 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Our main legacies and ECOFIT™ reference centers brand responsibilities BRAND FRANCE Grenoble FRANCE Mâcon GERMANY Regensburg UK Warrington USA West Chester ITALY Stezzano* CANADA Toronto* ✓ ✓ AREVA ✓ ✓ ALSTOM ✓ ✓ CEM ✓ DELLE ✓ AEG ✓ Sprecher + Schuh ✓ Concordia Sprecher ✓ VEM ✓ GEC ✓ ✓ ✓ GEC ALSTHOM ✓ ✓ AEI ✓ ✓ ✓ ✓ ✓ ✓ Competitors** ✓ ✓ ✓ ✓ ✓ ✓ ✓ * Not current ECOFIT™ reference centre ** ABB, Ansaldo, General Electric, Otto Buchwitz, VEB, Westinghouse, Siemens... ECOFIT™ Reference Centers are in charge of • Design and development of ECOFIT™ offers using Schneider Offer Creation Process methodology. • Industrialise, manufacture and optimise ECOFIT™ offers to answer the customers’ requests with optimum conditions. • Test, validation and certification of ECOFIT™ offers using a standard quality directive procedure linked to international standards. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 23 EOL, the complementary offer 24 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 End-of-life: environment in mind! 98% of a medium-voltage cubicle can be recovered. A legal requirement for the SF6, an environmental duty. In complement to ECOFIT™, EOL our high environmental treatment package: recovery and recycling for re-use of all medium-voltage equipment, including SF6 gas. EOL's 4 steps 1. Collection of medium-voltage equipment from your site. 2. Dismantling of the equipment in a Schneider Electric factory. The different ferrous and non-ferrous materials (copper, aluminium, etc.) are separated and sent to specialised recycling centres. 3. When applicable, the SF6 is evacuated until the residual pressure is less than 20 mbar, in accordance with the IEC standard, using adequate engineered tools. The gas is stored in bottles before being sent for recycling. The epoxy enclosure is crushed for recovery purposes. 4. A certificate of destruction compliant with the regulations is sent to you. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 25 Schneider Electric know-how 26 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Benefit from Schneider Electric image and know-how Our common values Schneider Electric’s policy has always been to provide its customers with very close support in their daily activities to enable them to achieve operational excellence. •Quality •Safety •Professionalism The experience of a world leader in Low & Medium Voltage Local support all over the worl. There are always Schneider Electric people close to you: A long history of innovation for a global offer 6200 Based on this experience as world leader, Schneider Electric has developed a large and comprehensive range of innovative devices. With one of the world leaders, you take benefit of a global leader experience and know-how in electric distribution, automation and Power & Control. services people in more than 88 Schneider Electric has been manufacturing LV and MV products for more than 50 years and its installed base amounts to thousand millions products and devices. The Schneider Electric brand is known worldwide and recognized by the most demanding customers. All the devices included in this overview have been designed and manufactured to incorporate the benefits of this extensive experience. Schneider Electric, a brand you can trust countries 5% of sales devoted to R&D More than 60,000 ECOFIT™ in services/delivered in various business segments Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 27 Medium Voltage Distribution Medium Voltage Distribution Contents MV CB or Contactor or Disconnector 5-15 kV MC switchgear AHA All with fixed CB Alliance Belledonne B200-B400 Belledonne B200G Belledonne B650 Belledonne B900 BVP 17 Cemabloc-C23mc 15 & 27 Cemabloc-C26.0 Composit CSIM 1-12 CSIM 3-12 DNF4-2E DNF4 MI&FI DNF5/DNF5-2B DNF6 DNF7 Epoclad Fluair F100-F200 Fluair F100C Fluair F300 Fluair F400C Fluair F400G Fluokit M24 Fluokit M24+ Fluokit M36 GS-10 HMC 400 & HMC 410 HMC 1072 HMC 1172 HMX 36 HP HWX K104 KAD KRU 2-10 MC500 Metalclad switchgear Motorstart P50D Motorstart P500D MX 51 & MX 81 Normabloc N1347 Normaclad PX PIX 12 - 24 PIX SF6 PNX 36 R RSW Siclad Solenarc DSE Metal-Clad switchgear Venus VISAX VM6 DM12 VMX WBA WBB WBD WK YSF6 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 MV Panel A-2 A-3 A-4 A-5 A-6 A-7 A-8 A-9 A-10 A-11 A-12 A-13 A-14 A-15 A-16 A-17 A-18 A-19 A-20 A-21 A-22 A-23 A-24 A-25 A-26 A-27 A-28 A-29 A-30 A-31 A-32 A-33 A-34 A-35 A-36 A-37 A-38 A-39 A-40 A-41 A-42 A-43 A-44 A-45 A-46 A-47 A-48 A-49 A-50 A-51 A-52 A-53 A-54 A-55 A-56 A-57 A-58 A-59 A-60 A-61 A-62 AHA DNF7 F100/200 PIX PNX36 PX 12-24 R VISAX VMX WBA WBB WBD WK A-63 A-64 A-65 A-66 A-67 A-68 A-69 A-70 A-71 A-72 A-73 A-74 A-75 MV Cradle to Cradle All All A-76 A-77 A-1 Medium Voltage Distribution 5 - 15 kV MC switchgear / VAD2 - 3 by MAGNUM Square D ECOFIT™ proposal PE90543 PE90542 Original brand: With ECOFIT™, a true extended life time < 1985 1995 2004 2006 VAD2-3 Magnum ECOFIT™ solution VAD2-3 Circuit Breaker End of commercialisation End of spare parts PE90544 Commercialisation Main technical characteristics Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) Magnum Circuit Breaker Magnum 5SSB VAD2 VAD3 VAD2 VAD3 1200 - 3000 A 29 kA 5 kV 41 kA 18 - 28 kA 15 kV 37 kA Magnum 5SSB Magnum 15SSB Magnum 15SSB Technology Vacuum Vacuum Rated current Ir (A) 1200 - 3000 1200 - 3000 Rated voltage Ur (kV) 5 15 Short circuit current Isc (kA) 29 - 41 18 - 28 Surge withstand voltage Up (kV) 60 95 Switching sequence O-0.3 s-CO-15 s-CO O-0.3 s-CO-15 s-CO Nominal frequency (Hz) 60 Opening time (ms) 60 60 60 Magnum CB main characteristics Built with totally new components and tested to ANSI standards, Magnum circuit breakers correctly interface with the existing breaker compartment components and maintain safety interlocks inherent in the original equipment design. •New circuit breakers are installed in existing switchgear. •Original footprint is left intact, saving time and money. •Installation expense is a fraction of new equipment costs. --Less down time for installation. --Enhanced equipment reliability. • Manufactured with new components. • Undergoes complete factory testing. • Backed by our standard equipment warranty. • New, easy-to-maintain operating mechanism. • No bulky arc chutes to handle and maintain. • Reduced need for difficult to obtain spare parts. Offer extension PE90437 PE90542 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-2 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution AHA / ECA by HVX-O2 Original brand: AEG - Alsthom - Alstom PE91041 ECOFIT™ proposal With ECOFIT™, a true extended life time PE91042 1997 2005 2012 2015 ECA HVX-O2 ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE91040 ECA Circuit Breaker Main technical characteristics ECA Rated current (Ir) Intensity short circuit (Isc) Rated voltage Un (50/60 Hz) HVX-O2 Circuit Breaker 630 - 1250 A 25 - 31.5 kA 12 - 17.5 kV HVX-O2 Technology Vacuum Rated voltage Ur (kV) 17.5 HVX-O2 Switching sequence O-0.3 s-CO-3 min-CO Surge withstand voltage Up (kV) 95 Closing time (ms) 35 Nominal frequency (Hz) 50 Opening time (ms) 53 Rated current Ir (A) Up to 1250 31.5 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE91041 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-3 Medium Voltage Distribution All with fixed CB / All fixed CB types by HVXUW Original brand: all brands ECOFIT™ proposal All breaker types Compatible with all open Air Insulated Switchgear legacy and no legacy cubicles with minimum inside panel width ≥ 650 mm With ECOFIT™, a true extended life time PE9075 This solution consist in fitting a cradle inside an existing panel. - It is particularly adapted for non Schneider Installed Base. - ECOFIT™ solution with shutters and mechanical interlocks embedded. - Only the fixed connections (between the cradle and existing busbar) are customized. - No age condition of the existing equipment. - Only the width of the existing panel has to be considered. Main technical characteristics All types Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) Withdrawable HVXUW Circuit Breaker 630 - 2500 A Up to 31.5 kA 12 kV Up to 31.5 kA 24 kV HVXUW Technology SF6 Rated voltage Ur (kV) 12 - 24 HVXUW Switching sequence O-0.3 s-CO-3min-CO Surge withstand voltage Up (kV) 75 - 125 Closing time (ms) 45 - 63 Nominal frequency (Hz) 50 - 60 Opening time (ms) 35 - 53 Rated current Ir (A) 630 - 2500 16 - 50 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90487 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-4 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution ALLIANCE / FP - GFA by FP - GFA Original brand: Alsthom PE90760 ECOFIT™ proposal With ECOFIT™, a true extended life time 1995 2013 2027 PE90761 FP - GFA FP - GFA ECOFIT™ solution Commercialisation End of spare parts PE90761 FP - GFA Circuit Breaker Main technical characteristics Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FP - GFA Circuit Breaker FP GFA Technology SF6 SF6 Rated voltage Ur (kV) 7.2 - 12 7.2 FP GFA 400 - 3150 A 16 - 50 kA 60 - 75 kV 400 A 10 kA 60 kV FP GFA Switching sequence O-3 min-CO-3 min-CO C/O CO-15 s-CO O-0.3 s-CO-3 min-CO Surge withstand voltage Up (kV) 60 - 75 60 Closing time (ms) 50 45 - 175 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) 70 90 - 120 Rated current Ir (A) 400 - 3150 400 300000 (mechanical) 16 - 50 10 Number of switching operations 10000 (mechanical) Short circuit current Isc (kA) Short circuit duration Tk (s) 1 1 Service temperature (°C) - 5 / + 40 - 5 / + 40 Offer extension PE90437 PE90760 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-5 Medium Voltage Distribution Belledonne B200-B400 / DSE22 to DSE78 Original brand: Merlin Gerin by LF2 -LF3- SF1 - Evolis ECOFIT™ proposal With ECOFIT™, a true extended life time PE90400 1972 1986 1988 2001 DSE22 to DSE78 LF2 - LF3 - SF1 - Evolis ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90401 DSE22 to DSE78 Circuit Breaker Main technical characteristics DSE to DSE78 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) LF2 - LF3 - SF1 Evolis Circuit Breaker LF2 / LF3 LF2 / LF3 SF1 630 - 3500 A 29 - 50 kA 7.2 kV 630 - 3150 A 24 - 48 kA 12 kV Evolis 15 - 46 kA 17.5 kV LF2 Technology SF6 SF6 SF6 Vacuum Rated voltage Ur (kV) 7.2 - 12 17.5 24 7.2 - 12 - 17.5 Surge withstand voltage Up (kV) 60 - 75 95 125 Nominal frequency (Hz) 50 - 60 50 - 60 50 - 60 Rated current Ir (A) 630 - 3150 630 - 3150 630 - 1250 630 - 2500 Short circuit current Isc (kA) 29 - 50 29 - 40 10 - 25 Short circuit duration Tk (s) 3 3 3 10 - 29 kA 24 kV LF3 SF1 Evolis Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO 60 - 75 - 95 Closing time (ms) < 72 < 65 < 65 50 - 60 Opening time (ms) < 654 < 50 < 50 Number of switching operations 10000 10000 10000 10000* 40 4 Service temperature (°C) - 25 / + 40 - 25 / + 40 - 25 / + 40 - 25 / + 40 * class MI: 2000 operations for Isc:40 kA Offer extension PE90415 PE90437 Energy management: replacement of the old protection relay (Schneider Electric or competitors) or PE90488 A-6 Sepam series 10, 20, 40, 60 , 80 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Belledonne B200G / DSE22K - DSE23K by LF1 - Evolis Original brand: Merlin Gerin ECOFIT™ proposal PE90403 With ECOFIT™, a true extended life time 1971 1988 1992 DSE22K - DSE23K LF1 - Evolis ECOFIT™ solution Commercialisation End of commercialisation End of space parts PE90404 DSE22K - DSE23K Circuit Breaker Main technical characteristics DSE22K - DSE23K Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) LF1 - Evolis Circuit Breaker LF1 Evolis Technology SF6 Vacuum Rated voltage Ur (kV) 7.2 7.2 630 - 1250 A 25 -31.5 kA 7.2 kV LF1 Evolis Switching sequence O-3 min-CO-3 min-CO O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 60 60 Closing time (ms) < 72 < 65 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) < 54 < 50 Rated current Ir (A) 630 - 1250 630 - 1250 2000* - 10.000 25 - 31.5 25 - 31.5 Number of switching operations 10000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 25 / + 40 - 25 / + 40 * Class M1: 2000 operations for Isc = 40 kA Offer extension PE90437 PE90403 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-7 Medium Voltage Distribution Belledonne B650 / DIS by LF1 - R400 - R400D - EVOLIS Original brand: Merlin Gerin PE90396 ECOFIT™ proposal With ECOFIT™, a true extended life time 1976 PE90397 1958 1986 1988 DIS LF1 - R400 - R400D - Evolis ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90398 DIS Circuit Breaker Main technical characteristics DIS Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) LF1 - R400 - R400D - EVOLIS Circuit Breaker LF1 R400 R400D 400 - 1250 A 25 - 31.5 kA 7.2 kV Evolis LF1 Technology SF6 SF6 SF6 Vacuum Rated voltage Ur (kV) 7.2 7.2 7.2 7.2 Surge withstand voltage Up (kV) 60 60 60 Nominal frequency (Hz) 50 - 60 50 - 60 50 - 60 Rated current Ir (A) 630 - 1250 80 - 250 Short circuit current Isc (kA) 31.5 50* Short circuit duration Tk (s) 3 3 3 R400 R400D Evolis Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO 60 Closing time (ms) < 72 75 - 155 75 - 155 < 65 50 - 60 Opening time (ms) < 54 20 - 50 20 - 50 < 50 80 - 250 630 - 2500 300000 100000 10000 25 - 31.5 Number of switching operations 10000 50* 3 Service temperature (°C) - 25 / + 40 - 25 / + 40 - 25 / + 40 - 25 / + 40 * With fuses Offer extension PE90437 PE90396 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-8 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Belledonne B900 / DIS by SF1 Original brand: Merlin Gerin PE90396 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90397 1961 1978 1988 1992 DIS SF1 ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90399 DIS Circuit Breaker Main technical characteristics DIS Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) SF1 Circuit Breaker 400 - 1250 A 12.5 kA 23 kV SF1 Technology SF6 Rated voltage Ur (kV) 24 SF1 Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 125 Closing time (ms) < 65 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 50 Rated current Ir (A) 630 - 1250 10.000 Short circuit current Isc (kA) 25 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90396 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-9 Medium Voltage Distribution BVP 17 / BVP 17 by VMX Original brand: AEI - GEC - GEC Alsthom PE90604 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90605 1965 1984 2001 2006 BVP 17 VMX ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90606 BVP 17 Circuit Breaker Main technical characteristics BVP 17 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) VMX Circuit Breaker 400 - 1250 A 25 kA 11 kV VMX Technology Vacuum Rated voltage Ur (kV) 11 VMX Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) Up to 75 Closing time (ms) < 52 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 61 Rated current Ir (A) 400 - 1250 10.000 Short circuit current Isc (kA) Up to 25 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90604 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-10 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Cemabloc C23mc 15 & 27 / CB by FP Original brand: CEM PE90461 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90462 1963 1984 1994 2010 CB FP ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90463 CB Circuit Breaker Main technical characteristics CB Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FP Circuit Breaker 400 - 1250 A 12.5 - 16/25 kA 23 kV FP Technology SF6 Rated voltage Ur (kV) 24 FP Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 125 Closing time (ms) 50 Nominal frequency (Hz) 50 - 60 Opening time (ms) 70 Rated current Ir (A) 400 - 3150 10.000 Short circuit current Isc (kA) 12.5 - 40 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90461 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-11 Medium Voltage Distribution PE90763 PE90762 PE90466 Cemabloc - C26.0 / CS by FPR - C26.1 / CX by FPR Original brand: CEM - C26.2 /FPR by FPR ECOFIT™ proposal With ECOFIT™, a true extended life time 1982 PE90467 1976 1985 1991 CS - CX - FPR FPR ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90468 CS Circuit Breaker Main technical characteristics CS FPR Circuit Breaker Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) 400 - 1250 A 14.5 kA 24 kV FPR Technology SF6 Rated voltage Ur (kV) 24 CX FPR 400 - 1250 A 12.5 kA 24 kV FPR Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 125 Closing time (ms) 50 Nominal frequency (Hz) 50 - 60 Opening time (ms) 80 Rated current Ir (A) 400 - 1250 10.000 Short circuit current Isc (kA) 12.5 Number of switching operations Short circuit duration Tk (s) 1 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90466 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-12 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Composit (860mm width) / MG by SF1 Original brand: Nuova Magrini Galileo PE90575 ECOFIT™ proposal With ECOFIT™, a true extended life time 1993 2000 PE90576 1966 2010 MG SF1 ECOFIT™ solution Commercialisation End of commercialisation End of spare parts MG Circuit Breaker PE90232 Main technical characteristics MG SF1 Circuit Breaker 150-500 150-750 350-750 150-750 350-750 Rated current (Ir) 630 - 1250 A 630 - 1250 A 630 - 1250 A 630 - 1250 A 630 - 1250 A Short circuit current (Isc) Rated voltage Un (50/60 Hz) 8.7 - 28.9 kA 10 kV 5 - 29 kA 15 kV 12.5 - 29 kA 17 kV 3.6 - 24 kA 20 kV 6.3 - 21.7 kA 24 kV SF1 Technology SF6 Rated voltage Ur (kV) 17.5 - 24 SF1 Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 95 - 125 Closing time (ms) < 65 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 50 Rated current Ir (A) 630 - 1250 10.000 Short circuit current Isc (kA) 25 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90575 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-13 Medium Voltage Distribution CSIM 1-12 / SCI-4 by VEIVACUUM F Original brand: VEB " Otto Buchwitz " PE90560 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90561 1975 1991 2006 SCI-4 VEIVACUUM F ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90562 SCI-4 Circuit Breaker Main technical characteristics SCI-4 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) VEIVACUUM F Circuit Breaker 630 - 1250 A 16 - 31.5 kA 12 kV VEIVACUUM F Technology Vacuum Rated voltage Ur (kV) 12 VEIVACUUM F Switching sequence O-0.3 s-CO-3min-CO Surge withstand voltage Up (kV) 75 Closing time (ms) 65 Nominal frequency (Hz) 50 - 60 Opening time (ms) 50 Rated current Ir (A) 600 - 1250 10.000 Short circuit current Isc (kA) 25 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90563 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-14 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution CSIM 3-12 / SCI-4 by VEIVACUUM F - VA Original brand: VEB " Otto Buchwitz " PE90640 ECOFIT™ proposal With ECOFIT™, a true extended life time 1975 1991 2006 2012 SCI-4 VEIVACUUM F - VA ECOFIT™ solution SCI-4 Circuit Breaker End of commercialisation End of spare parts PE90641 Commercialisation Main technical characteristics SCI-4 Rated current (Ir) Intensity short circuit (Isc) Rated voltage Un (50/60 Hz) VEIVACUUM F - VA Circuit Breaker 630 - 2500 A 16 - 31.5 kA 12 kV VEIVACUUM F - VA Technology Vacuum Rated voltage Ur (kV) 12 VEIVACUUM F - VA Switching sequence O-0.3 s-CO-3min-CO Surge withstand voltage Up (kV) 75 Closing time (ms) 45 - 65 Nominal frequency (Hz) 50 - 60 Opening time (ms) 45 - 65 Rated current Ir (A) 600 - 3150 10.000 Short circuit current Isc (kA) 25 - 40 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90563 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-15 Medium Voltage Distribution DNF4-2E / FP - GFA by FP - HVX - CVX Original brand: Alsthom PE90667 ECOFIT™ proposal With ECOFIT™, a true extended life time 1983 1997 2007 2009 PE90668 FP - GFA FP - HVX - CVX ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90669 FP - GFA Circuit Breaker Main technical characteristics FP - GFA Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FP - HVX - CVX Circuit Breaker FP HVX 400 - 2000 A 40 kA 12 kV CVX Technology SF6 Vacuum Vacuum Rated voltage Ur (kV) 12 12 12 Surge withstand voltage Up (kV) 75 75 Nominal frequency (Hz) 50 - 60 50 - 60 Rated current Ir (A) 400 - 3150 Short circuit current Isc (kA) 12 - 50 Short circuit duration Tk (s) 3 FP HVX CVX Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO* CO-15s-CO O-0.3 s-CO-15 s-CO* O-0.3 s-CO-3min-CO** C/O 75 Closing time (ms) 50 35 - 53 40 - 80 50 - 60 Opening time (ms) 70 45 - 63 100 - 200 630 - 3150 400 10.000 4 Number of switching operations 10.000 16 - 50 300.000 (mech.) 500.000 (elec.) 3 1 Service temperature (°C) - 5 / + 40 - 5 / + 40 - 25 / + 40 * HVX only / ** FP only Offer extension PE90437 PE90670 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-16 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution DNF4 MI & FI / FP by FP - HVX Original brand: Alsthom PE90671 ECOFIT™ proposal With ECOFIT™, a true extended life time 1997 PE90672 1983 2007 2010 FP FP - HVX ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90673 FP Circuit Breaker Main technical characteristics FP Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FP - HVX Circuit Breaker FP 400 - 2500 A 40 kA 12 kV HVX Technology SF6 Vacuum Rated voltage Ur (kV) 12 12 FP HVX Switching sequence O-3 min-CO-3 min-CO O-3 min-CO-3 min-CO CO-15s-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-3 min-CO CO-15s-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 75 75 Closing time (ms) 50 35 - 53 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) 70 45 - 63 Rated current Ir (A) 400 - 3150 630 - 3150 10.000 16 - 50 25 - 50 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 5 / + 40 - 5 / + 40 Offer extension PE90437 PE90671 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-17 Medium Voltage Distribution DNF5 - DNF5-2B / FP by FP - HVX Original brand: Alsthom PE90678 ECOFIT™ proposal With ECOFIT™, a true extended life time 1997 PE90672 1983 2007 2011 FP FP - HVX ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90673 FP Circuit Breaker Main technical characteristics FP Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FP - HVX Circuit Breaker FP HVX Technology SF6 Vacuum Rated voltage Ur (kV) 17.5 17.5 630 - 2000 A 40 kA 17.5 kV FP Switching sequence HVX O-3 min-CO-3 min-CO O-3 min-CO-3 min-CO CO-15s-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-3 min-CO CO-15s-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 75 75 Closing time (ms) 50 35 - 53 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) 70 45 - 63 Rated current Ir (A) 400 - 3150 630 - 3150 10.000 16 - 40 25 - 40 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 5 / + 40 - 5 / + 40 Offer extension PE90437 PE90678 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-18 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution DNF6 / FP by FP - HVX Original brand: Alsthom PE90679 ECOFIT™ proposal With ECOFIT™, a true extended life time 1997 PE90680 1987 2007 2011 FP FP - HVX ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90673 FP Circuit Breaker Main technical characteristics FP Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FP - HVX Circuit Breaker FP 400 - 2000 A 31.5 kA 24 kV HVX Technology SF6 Vacuum Rated voltage Ur (kV) 24 24 FP HVX Switching sequence O-3 min-CO-3 min-CO O-3 min-CO-3 min-CO CO-15s-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-3 min-CO CO-15s-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 75 75 Closing time (ms) 50 35 - 53 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) 70 45 - 63 Rated current Ir (A) 400 - 3150 630 - 2500 10.000 16 - 40 25 - 40 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 5 / + 40 - 5 / + 40 Offer extension PE90437 PE90679 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-19 Medium Voltage Distribution DNF7 / FP by FP - HVX-O2 Original brand: Alsthom PE90674 ECOFIT™ proposal With ECOFIT™, a true extended life time 2013 2024 PE90675 1983 FP FP - HVX-O2 ECOFIT™ solution Commercialisation PE90676 FP Circuit Breaker End of commercialisation End of spare parts Main technical characteristics FP Rated current (Ir) Intensity short circuit (Isc) Rated voltage Un (50/60 Hz) FP - HVX-O2 Circuit Breaker FP 400 - 2000 A 31.5 kA 36 kV HVX-O2 Technology SF6 Vacuum Rated voltage Ur (kV) 36 40.5 Switching sequence FP HVX-O2 O-0.3 s-CO-3 min-CO O-0.3 s-CO-15s-CO CO-15 s-CO O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-3 min-CO-3 min-CO O-0.3 s-CO-15s-CO CO-15 s-CO Surge withstand voltage Up (kV) 170 185 Closing time (ms) 50 45 - 53 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) 70 45 - 63 Rated current Ir (A) Up to 2500 Up to 2500 10.000 31.5 31.5 Number of switching operations 5.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 5 / + 40 - 5 / + 40 Offer extension PE90437 PE90674 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-20 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Epoclad / DHF & F by LF1 - LF2 - LF3 - SF1 Original brand: Nuova Magrini Galileo PE90577 ECOFIT™ proposal With ECOFIT™, a true extended life time DHF - F Circuit Breaker 1969 1997 2005 2011 DHF & F LF1 - LF2 - LF3 - SF1 ECOFIT™ solution End of commercialisation End of spare parts PE90579 Commercialisation Main technical characteristics DHF & F 6DHF 6DHF/N 250-500 7F/N 250-350 10DHF 250-750 7F 350-750 15DHF 350-850 12F 12F/N 350-750 24DHF 350-500 20DHF 350-750 24F 500-750 Rated current (Ir) 630 - 3150 A 630 - 3150 A 630 - 3150 A 630 - 3150 A 630 - 1250 A 630 - 3150 A 630 - 3150 A 630 - 1250 A Short circuit current (Isc) 20 - 48 kA 29 - 34 kA 12 - 43 kA 18 - 48 kA 13.5 - 32.5 kA 12.5 - 48 kA 9.2 - 14.5 kA Rated voltage Un (50/60 Hz) 6 kV 7.2 kV 10 kV 12 kV 15 kV 17 kV 20 kV LF1 - LF2 LF3 - SF1 Circuit Breaker LF1 LF2 LF3* SF1 LF1 Technology SF6 SF6 SF6 SF6 Rated voltage Ur (kV) 7.2 7.2 - 12 17.5 24 Surge withstand voltage Up (kV) 60 60 - 75 95 Nominal frequency (Hz) 50 - 60 50 - 60 50 - 60 Rated current Ir (A) 630 - 1250 2000 / 630 - 3150 630 - 1250 up to 2000 Short circuit current Isc (kA) 31.5 50 - 40 40 25 Short circuit duration Tk (s) 3 3 3 3 LF2 8 - 18 kA /20DHF 12.5 - 18 kA /24F 24 kV LF3* SF1 Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO 125 Closing time (ms) < 72 < 72 < 72 < 65 50 - 60 Opening time (ms) < 54 < 54 < 54 < 50 Number of switching operations 10.000 10.000 10.000 10.000 Service temperature (°C) - 25 / + 40 - 25 / + 40 - 25 / + 40 - 25 / + 40 * Ur: 7.2 / 12, A: 3150, kA: 50 Offer extension PE90577 PE90437 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-21 Medium Voltage Distribution Fluair F100 - F200 / FG1 - FG2 by LF2 - LF3 - Evolis Original brand: Merlin Gerin PE90409 ECOFIT™ proposal With ECOFIT™, a true extended life time 1980 1998 1999 2011 FG1 - FG2 LF2 - LF3 - Evolis ECOFIT™ solution Commercialisation PE90411 FG1 - FG2 Circuit Breaker End of commercialisation End of spare parts Main technical characteristics FG1 - FG2 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) LF2 - LF3 - EVOLIS Circuit Breaker LF2 - LF3 630 - 3150 A 25 - 50 kA 7.2 kV 630 - 3150 A 25 - 50 kA 12 kV Evolis 630 - 3150 A 25 - 31.5 kA 17.5 kV LF2 - LF3 Technology SF6 SF6 Vacuum Rated voltage Ur (kV) 7.2 - 12 17.5 up to 17.5 Evolis Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 60 - 75 95 up to 95 Closing time (ms) < 72 < 72 < 65 Nominal frequency (Hz) 50 - 60 50 - 60 50 - 60 Opening time (ms) < 54 < 54 < 50 Rated current Ir (A) 630 - 3150 630 - 3150 630 - 2500 10.000 25 - 50 31.5 40 Number of switching operations 10.000 Short circuit current Isc (kA) 2000 (Isc = 40 kA / M1 class) - 10.000 Short circuit duration Tk (s) 3 3 3 Service temperature (°C) - 25 / + 40 - 25 / + 40 - 25 / + 40 Offer extension PE90437 PE90409 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-22 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Fluair F100C / R400 - R400D by R400 - R400D Original brand: Merlin Gerin PE90412 ECOFIT™ proposal With ECOFIT™, a true extended life time 1980 1998 R400 - R400D R400 - R400D ECOFIT™ solution Commercialisation End of spare parts PE90413 R400 - R400D Circuit Breaker R400 - R400D Circuit Breaker Main technical characteristics R400 R400D Technology SF6 SF6 Rated voltage Ur (kV) 7.2 7.2 R400 R400D Switching sequence Surge withstand voltage Up (kV) 60 60 Closing time (ms) 75 - 155 75 - 155 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) 20 - 50 20 - 50 Rated current Ir (A) 80 - 250 80 - 250 100.000 50 (with fuses) 50 (with fuses) Number of switching operations 300.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 25 / + 40 - 25 / + 40 Offer extension PE90437 PE90412 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-23 Medium Voltage Distribution Fluair F300 / FG3 (1000mm width) by SF1 - SF2 Original brand: Merlin Gerin PE90742 ECOFIT™ proposal With ECOFIT™, a true extended life time 1980 1998 1999 2009 FG3 SF1 - SF2 ECOFIT™ solution Commercialisation PE90744 FG3 Circuit Breaker End of commercialisation End of spare parts Main technical characteristics FG3 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) SF1 - SF2 Circuit Breaker SF1 SF2 Technology SF6 SF6 Rated voltage Ur (kV) 24 24 630 - 2500 A 25 - 31.5 kA 24 kV SF1 Switching sequence SF2 O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 125 125 Closing time (ms) < 65 < 65 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) < 50 < 50 Rated current Ir (A) 630 - 1250 1250 - 2500 10.000 25 25 - 31.5 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 25 / + 40 - 25 / + 40 Offer extension PE90437 PE90409 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-24 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Fluair F400C / FC4 by SF2 Original brand: Merlin Gerin PE90414 ECOFIT™ proposal With ECOFIT™, a true extended life time 1980 1987 1991 2000 FC4 SF2 ECOFIT™ solution Commercialisation PE90416 FC4 Circuit Breaker End of commercialisation End of spare parts Main technical characteristics FC4 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) SF2 Circuit Breaker 1250 - 2500 A 31.5 - 40 kA 36 kV SF2 Technology SF6 Rated voltage Ur (kV) 36 SF2 Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 170 Closing time (ms) < 65 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 50 Rated current Ir (A) 1250 - 2500 10.000 Short circuit current Isc (kA) 31.5 - 40 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90414 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-25 Medium Voltage Distribution Fluair F400G / FG4 by SF1 - SF2 Original brand: Merlin Gerin PE90417 ECOFIT™ proposal With ECOFIT™, a true extended life time 1986 2002 2004 2009 FG4 SF1 - SF2 ECOFIT™ solution Commercialisation PE90450 FG4 Circuit Breaker End of commercialisation End of spare parts Main technical characteristics FG4 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) SF1 - SF2 Circuit Breaker 1250 - 2500 A 40 kA 24 kV 1250 - 3150 A 25 - 40 kA 36 kV SF1 - SF2 Technology SF6 Rated voltage Ur (kV) 24 - 36 SF1 - SF2 Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 125 - 170 Closing time (ms) < 65 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 50 Rated current Ir (A) 1250 - 2500 10.000 Short circuit current Isc (kA) 25 - 40 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90417 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-26 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Fluokit M24 / FP by FP Original brand: DELLE ALSTHOM PE90864 ECOFIT™ proposal With ECOFIT™, a true extended life time 1987 2007 2011 2014 PE90863 FP FP ECOFIT™ solution Commercialisation End of commercialisation End of spare parts FP Circuit Breaker PE90863 Main technical characteristics FP Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FP Circuit Breaker 400 - 3150 A 16 - 20 - 25 - 31.5 - 40 kA 12 kV FP 400 - 3150 A 16 - 20 - 25 - 31.5 - 40 kA 24 kV FP Technology SF6 SF6 Rated voltage Ur (kV) 12 24 Switching sequence O-3mn-CO-3mn-CO CO-15 s-CO O-0.3 s-CO-3mn-CO Surge withstand voltage Up (kV) 75 125 Closing time (ms) 70 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) 50 Rated current Ir (A) 400 - 3150 400 - 3150 16 - 20 - 25 - 31.5 - 40 16 - 20 - 25 - 31.5 - 40 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90864 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-27 Medium Voltage Distribution Fluokit M24+ / FP by FP Original brand: DELLE ALSTHOM PE90862 ECOFIT™ proposal With ECOFIT™, a true extended life time 2005 2014 2024 PE90863 FP FP ECOFIT™ solution Commercialisation End of commercialisation End of spare parts FP Circuit Breaker PE90863 Main technical characteristics FP Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FP Circuit Breaker 400 - 3150 A 16 - 20 - 25 - 31.5 - 40 kA 12 kV FP 400 - 3150 A 16 - 20 - 25 - 31.5 - 40 kA 24 kV FP Technology SF6 SF6 Rated voltage Ur (kV) 12 24 Switching sequence O-3mn-CO-3mn-CO CO-15 s-CO O-0.3 s-CO-3mn-CO Surge withstand voltage Up (kV) 75 125 Closing time (ms) 70 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) 50 Rated current Ir (A) 400 - 3150 400 - 3150 16 - 20 - 25 - 31.5 - 40 16 - 20 - 25 - 31.5 - 40 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90862 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-28 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Fluokit M36 / FP by FP Original brand: DELLE ALSTHOM PE90860 ECOFIT™ proposal With ECOFIT™, a true extended life time 1987 2014 2024 PE90861 FP FP ECOFIT™ solution Commercialisation End of commercialisation End of spare parts FP Circuit Breaker PE90861 Main technical characteristics FP Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FP Circuit Breaker 400 - 3150 A 16 - 20 - 25 - 31.5 kA 36 kV FP Technology SF6 Rated voltage Ur (kV) 36 FP Switching sequence O-3mn-CO-3mn-CO CO-15 s-CO O-0.3 s-CO-3mn-CO Surge withstand voltage Up (kV) 170 Closing time (ms) 70 Nominal frequency (Hz) 50 - 60 Opening time (ms) 50 Rated current Ir (A) 400 - 3150 16 - 20 - 25 - 31.5 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90860 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-29 Medium Voltage Distribution GS-10 / GE by VA - VAA Original brand: AEG PE90550 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90551 1966 1978 2004 2009 GE VA - VAA ECOFIT™ solution Commercialisation PE90552 GE Circuit Breaker End of commercialisation End of spare parts Main technical characteristics GE Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) VA - VAA Circuit Breaker 630 - 3000 A 16 - 40 kA 12 kV VA - VAA Technology Vacuum Rated voltage Ur (kV) 12 VA - VAA Switching sequence O-0.3 s-CO-3min-CO Surge withstand voltage Up (kV) 75 Closing time (ms) 45 - 65 Nominal frequency (Hz) 50 - 60 Opening time (ms) 45 - 65 Rated current Ir (A) 600 - 1250 10.000 Short circuit current Isc (kA) 40 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90553 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-30 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution HMC400 - HMC410 / HMC400 - HMC410 Original brand: GEC Alstom by HMC400 - HMC410 PE90597 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90594 1960 1970 2015 HMC400 - HMC410 HMC400 - HMC410 ECOFIT™ solution PE90595 HMC400 - HMC410 Circuit Breaker Commercialisation End of commercialisation End of spare parts Main technical characteristics HMC400 - HMC410 HMC400 - HMC410 Circuit Breaker Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) 400 A 43.8 kA 3.3 kV 400 A 26.3 kA 6.6 kV HMC400 - HMC410 Technology Vacuum Rated voltage Ur (kV) Up to 6.6 HMC400 - HMC410 Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) Up to 75 Closing time (ms) < 52 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 61 Rated current Ir (A) 400 10.000 Short circuit current Isc (kA) 26.3 - 43.8 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 PE90681 Refurbishment In-house refurbishment, including vacuum contactors and control scheme utlilising Gemstart unit, on site maintenance Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-31 Medium Voltage Distribution HMC1072 /HMC1072 by HMC1072 Original brand: GEC Alstom PE90599 ECOFIT™ proposal With ECOFIT™, a true extended life time 1968 1983 1992 2015 HMC1072 HMC1072 ECOFIT™ solution Commercialisation End of commercialisation End of spare parts Main technical characteristics HMC1072 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) HMC1072 400 A 63 kA rms/1s - 50 kA rms/3s 7.2 kV HMC1072 Technology Vacuum Rated voltage Ur (kV) 7.2 HMC1072 Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) Up to 75 Closing time (ms) < 52 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 61 Rated current Ir (A) 400 10.000 Short circuit current Isc (kA) 50 - 63 Number of switching operations Short circuit duration Tk (s) 3 to 1 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90599 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-32 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution HMC1172 /HMC1172 by HMC1172 Original brand: GEC Alstom ECOFIT™ proposal PE90600 With ECOFIT™, a true extended life time 1980 2006 2008 On-going HMC1172 HMC1172 ECOFIT™ solution HMC1172 Commercialisation End of commercialisation End of spare parts Main technical characteristics HMC1172 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) VCB 400 A 63 kA rms/1s - 50 kA rms/3s 7.2 kV Contactor Technology Vacuum Vacuum Rated voltage Ur (kV) 7.2 7.2 Surge withstand voltage Up (kV) 60 63 VCB Contactor Switching sequence O-3 min-CO-3 min-CO O/C O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Closing time (ms) 90 - 120 90 - 120 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) < 61 < 61 Rated current Ir (A) 1000 - 2000 400 10.000 1.000.000 Short circuit current Isc (kA) 25 - 31.5 9 Number of switching operations Short circuit duration Tk (s) 3 1 Service temperature (°C) - 25 / + 40 - 25 / + 40 Offer extension PE90437 PE90601 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-33 Medium Voltage Distribution HMX36 /HMX36 by HMX36 Original brand: GEC Alstom PE90602 ECOFIT™ proposal With ECOFIT™, a true extended life time 1980 2003 On-going HMX36 HMX36 ECOFIT™ solution HMX36 Commercialisation End of commercialisation End of spare parts Offer extension PE90437 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-34 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution HP / HP - W - TW - TM by HVX Original brand: Concordia Sprecher ECOFIT™ proposal With ECOFIT™, a true extended life time PE90653 1976 2002 2007 2012 HP - W - TW - TM HVX ECOFIT™ solution Commercialisation PE90652 HP - W - TW - TM Circuit Breaker End of commercialisation End of spare parts Main technical characteristics HP - W - TW - TM Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) HVX Circuit Breaker 1250 - 3150 A 12.5 - 40 kA 7.2 - 12 kV 800 - 1250 A 8.4 - 21.7 kA 24 kV HVX Technology Vacuum Rated voltage Ur (kV) 12 - 24 HVX Switching sequence O-0.3 s-CO-3 min-CO Surge withstand voltage Up (kV) 75 - 125 Closing time (ms) 45 - 63 Nominal frequency (Hz) 50 - 60 Opening time (ms) 35 - 53 Rated current Ir (A) 630 - 2500 16 - 31.5 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90654 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-35 Medium Voltage Distribution HWX / HWX by HWX Original brand: GEC, GEC Alsthom, Alstom, Areva ECOFIT™ proposal With ECOFIT™, a true extended life time PE91027 1996 2016 2020 HWX HWX ECOFIT™ solution Commercialisation PE91027 HWX Circuit Breaker End of commercialisation End of spare parts Main technical characteristics HWX Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) HWX Circuit Breaker 3150 A 50 kA 12 kV HWX Technology Vacuum Rated voltage Ur (kV) 12 HWX Switching sequence O-0.3 s-CO-3 min-CO Surge withstand voltage Up (kV) 75 Closing time (ms) ≤ 60 Nominal frequency (Hz) 50 Opening time (ms) ≤ 60 Rated current Ir (A) 3150 Short circuit current Isc (kA) 50 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE91027 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-36 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution K104/ K104 by LF - Evolis Original brand: GOST standard ECOFIT™ proposal PE91043 With ECOFIT™, a true extended life time <1980 2000 2012 K104 LF-Evolis ECOFIT™ solution Commercialisation End of commercialisation & End of spare parts PE91006 K104 Circuit Breaker Main technical characteristics K104 LF - Evolis Circuit Breaker Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) LF Evolis Technology SF6 Vacuum Rated voltage Ur (kV) 6 - 10 6 - 17.5 630 - 1000 - 1600 A 25 -31.5 kA 6 - 10 kV LF Evolis Switching sequence O-0,3 c-C/O-15 c-C/O O-0,3 c-C/O-15 c-C/O 3 min 3 min Surge withstand voltage Up (kV) 60 - 75 60 - 75 Closing time (ms) < 65 < 65 Nominal frequency (Hz) 50 50 Opening time (ms) < 50 < 50 Rated current Ir (A) 630 - 1250 - 2000 630 - 1250 - 1600 20.000 25 - 31.5 25 - 31.5 Number of switching operations 10000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 25 / + 40 - 25 / + 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-37 Medium Voltage Distribution KAD/ KAD/KAC by VMX-540 Original brand: GEC, GEC Alsthom, Alstom ECOFIT™ proposal PE91028 With ECOFIT™, a true extended life time < 1980 2002 2012 KAD VMX-540 ECOFIT™ solution KAD Circuit Breaker End of commercialisation End of spare parts PE91028 Commercialisation Main technical characteristics KAD VMX-540 Circuit Breaker Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) 800 A 25 kA 12 kV VMX-540 Technology Vacuum Rated voltage Ur (kV) 12 VMX-540 Switching sequence O-0.3 s-CO-3 min-CO Surge withstand voltage Up (kV) 75 Closing time (ms) ≤ 60 Nominal frequency (Hz) 50 Opening time (ms) ≤ 60 Rated current Ir (A) 1250 Short circuit current Isc (kA) 25 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) A-38 - 5 / + 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution KRU / KRU 2-10 by LF - Evolis Original brand: GOST standard ECOFIT™ proposal With ECOFIT™, a true extended life time PE91007 <1970 2000 2012 KRU 2-10 LF-Evolis ECOFIT™ solution Commercialisation End of commercialisation & End of spare parts PE91008 KRU 2-10 Circuit Breaker Main technical characteristics KRU 2-10 LF - Evolis Circuit Breaker Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) LF Evolis Technology SF6 Vacuum Rated voltage Ur (kV) 6 - 17.5 6 - 10 630 - 1000 - 1600 A 25 -31.5 kA 6 - 10 kV LF Evolis Switching sequence O-0,3 c-C/O-15 c-C/O O-0,3 c-C/O-15 c-C/O 3 min 3 min Surge withstand voltage Up (kV) 60 - 75 60 - 75 Closing time (ms) < 65 < 65 Nominal frequency (Hz) 50 50 Opening time (ms) < 50 < 50 Rated current Ir (A) 630 - 1250 - 2000 630 - 1250 - 1600 20.000 40 - 50 (6kV) - 40 (10 kV) 25 - 45 Number of switching operations 10000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 - 25 / + 40 3 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-39 Medium Voltage Distribution MC500 / SF1T by SF1T Original brand: Merlin Gerin PE91005 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90397 1997 2015 2034 SF1T SF1T ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90399 SF1T Circuit Breaker Main technical characteristics SF1T Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) SF1T Circuit Breaker 1250 - 4000 A 12.5 - 16.5 kA 24 kV SF1T Technology SF6 Rated voltage Ur (kV) 24 SF1T Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-15 s-CO O-0.3 s-CO-3 min-CO Surge withstand voltage Up (kV) 125 Closing time (ms) 70 Nominal frequency (Hz) 50 - 60 Opening time (ms) 50 Rated current Ir (A) 1250 - 4000 10.000 Short circuit current Isc (kA) 12.5 - 16.5 Number of switching operations Short circuit duration Tk (s) 1 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE91005 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-40 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Metalclad switchgear / DST2 & 5 by DST2V & 5V Original brand: Federal Pioneer PE90618-2 ECOFIT™ proposal With ECOFIT™, a true extended life time 1970 1985 1999 2000 PE90618 DST2 & 5 - DST2 FP DST2V & 5V ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90619 DST2 & 5 Circuit Breaker Main technical characteristics DST2V & 5V Circuit Breaker Rated current (Ir) 3-phase MVA rating Rated voltage Un DST2 V DST5 V Technology Vacuum Vacuum Rated voltage Ur (kV) 5 15 Surge withstand voltage Up (kV) 60 DST2 & 5 DST2 1200 - 3000 A 250 - 350 MVA 5 kV 1200 - 3000 A 500 - 750 MVA 15 kV DST2 V DST5 V Rated current Ir (A) 1200 - 3000 1200 - 3000 3-phase rating (MVA) 350 500 - 750 95 PE90619 Offer extension Magnum circuit breakers correctly interface with the existing breaker compartment components and maintain safety interlocks inherent in the original equipment design. • New circuit breakers are installed in existing switchgear. • Original footprint is left intact, saving time and money. • Installation expense is a fraction of new equipment costs. • Less down time for installation. • Enhanced equipment reliability. • Manufactured with new components. • Undergoes complete factory testing. • Backed by our standard equipment warranty. • New, easy-to-maintain operating mechanism. • No bulky arc chutes to handle and maintain. • Reduced need for difficult to obtain spare parts. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Optional capabilities • Increased fault current interruption rating. • Relay upgrade, improved accuracy and repeatability, and performance. • Power metering, monitoring and communication. • Ground and test devices available for various types of switchgear. Closed Door Electric Racking Mechanism • Arc flash hazard reduced with remote operation. • Maintenance shutdown time is significantly reduced. • No storage space is required for the electrical racking system. • Require just a common 120VAC, 15A outlet for power up. A-41 Medium Voltage Distribution Motorstart P50D / C - CD by R400 - R400D - CTV1 Original brand: Merlin Gerin PE90390 ECOFIT™ proposal With ECOFIT™, a true extended life time 1960 1980 1988 1992 PE90391 C - CD R400 - R400D - CTV1 ECOFIT™ solution Commercialisation PE90392 C - CD Circuit Breaker End of commercialisation End of spare parts Main technical characteristics C - CD Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) R400 - R400D - CTV1 Circuit Breaker 80 - 200 A 50 kA (with fuses) 7.2 kV R400 R400D CTV1 Technology SF6 SF6 Vacuum Rated voltage Ur (kV) 7.2 7.2 7.2 R400 R400D CTV1 Switching sequence Surge withstand voltage Up (kV) 60 60 60 Closing time (ms) 75 - 155 75 - 155 60 - 80 Nominal frequency (Hz) 50 - 60 50 - 60 50 - 60 Opening time (ms) 20 - 50 20 - 50 20 - 30 Rated current Ir (A) 80 - 250 80 - 250 80 - 250 Number of switching 50 (with fuses) 50 (with fuses) 50 (with fuses) operations 300.000 100.000 200.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 - 25 / + 40 - 25 / + 40 - 25 / + 40 3 3 Service temperature (°C) Offer extension PE90437 PE90390 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-42 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Motorstart P500D / C1 - CD1 by R400 - R400D - CTV1 Original brand: Merlin Gerin PE90393 ECOFIT™ proposal With ECOFIT™, a true extended life time 1971 1988 1998 C1 - CD1 R400 - R400D - CTV1 ECOFIT™ solution Commercialisation PE90395 C1 - CD1 Circuit Breaker End of commercialisation End of space parts Main technical characteristics C1 - CD1 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) R400 - R400D - CTV1 Circuit Breaker 80 - 250 A 50 kA (with fuses) 7.2 kV R400 R400D CTV1 Technology SF6 SF6 Vacuum Rated voltage Ur (kV) 7.2 7.2 7.2 R400 R400D CTV1 Switching sequence Surge withstand voltage Up (kV) 60 60 60 Closing time (ms) 75 - 155 75 - 155 60 - 80 Nominal frequency (Hz) 50 - 60 50 - 60 50 - 60 Opening time (ms) 20 - 50 20 - 50 20 - 30 Rated current Ir (A) 80 - 250 80 - 250 80 - 250 Number of switching 50 (with fuses) 50 (with fuses) 50 (with fuses) operations 300.000 100.000 200.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 - 25 / + 40 - 25 / + 40 - 25 / + 40 3 3 Service temperature (°C) Offer extension PE90437 PE90393 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-43 Medium Voltage Distribution MX51 & MX81 by MX51 & MX81 Original brand: GEC Alstom ECOFIT™ proposal PE90603 With ECOFIT™, a true extended life time 1974 1981 2012 MX51 & MX81 MX51 & MX81 ECOFIT™ solution Commercialisation End of commercialisation End of spare parts MX51 & MX81 Main technical characteristics MX51 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) MX81 630 - 2000 A 25 - 31.5 kA 3.6 kV 630 - 2000 A 25 - 31.5 kA 17.5 kV MX51 & MX81 Technology Vacuum Rated voltage Ur (kV) Up to 17.5 630 - 1250 A 12.5 - 20 kA 3.6 kV 630 - 1250 A 12.5 - 20 kA 17.5 kV MX51 & MX81 Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) Up to 115 Closing time (ms) < 52 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 61 Rated current Ir (A) 630 - 2000 10.000 Short circuit current Isc (kA) Up to 31.5 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90603 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-44 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Normabloc N1347 / HL by HVX -FPX Original brand: Delle Alsthom PE90481 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90482 1975 1981 1991 2009 HL HVX - FPX ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90483 HL Circuit Breaker Main technical characteristics HL Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) HVX - HPX Circuit Breaker HVX FPX Technology Vacuum SF6 Rated voltage Ur (kV) 17.5 17.5 630 - 1250 A 25 & 40 kA 17.5 kV HVX FPX Switching sequence O-3 min-CO-3 min-CO O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-3 min-CO O-15 s-CO O-0.3 s-CO-15s-CO O-0.3 s-CO-15s-CO Surge withstand voltage Up (kV) 95 95 Closing time (ms) 35 - 53 50 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) 45 - 63 50 Rated current Ir (A) 630 - 1250 630 - 1250 10000 16 - 40 12.5 - 40 Number of switching operations 10000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 5 / + 40 - 5 / + 40 Offer extension PE90437 PE90481 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-45 Medium Voltage Distribution Normaclad PX / FPX by FPX Original brand: GEC ALSTHOM PE90765 ECOFIT™ proposal With ECOFIT™, a true extended life time 1993 1997 2024 PE90857 FPX FPX ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90857 FPX Circuit Breaker Main technical characteristics FPX Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FPX Circuit Breaker Up to 3150 A 40 kA 12 kV Up to 2500 A 31.5 kA 24 kV FPX FPX Technology SF6 SF6 Rated voltage Ur (kV) 12 24 Switching sequence O-3mn-CO-3mn-CO CO-0.3 s-CO-15 s-CO O-0.3 s-CO-3mn-CO Surge withstand voltage Up (kV) 75 125 Closing time (ms) 50 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) 50 Rated current Ir (A) Up to 3150 Up to 2500 Up to 40 Up to 31.5 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90765 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-46 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution PX 12 - 24 / FPX by FPX Original brand: Alstom PE90765 ECOFIT™ proposal With ECOFIT™, a true extended life time 1993 1997 1998 2023 PE90766 FPX FP FPX ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90766 FPX Circuit Breaker Main technical characteristics FPX Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FPX Circuit Breaker 3150 A 40 kA/3s 12 kV 2500 A 31.5 kA/3s 17.5 kV FPX 2500 A 31.5 kA/3s 24 kV FPX Technology SF6 SF6 SF6 Switching sequence Rated voltage Ur (kV) 12 17.5 24 O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 100 80 80 Closing time (ms) 50 50 50 Nominal frequency (Hz) 50 - 60 Rated current Ir (A) 3150 50 - 60 50 - 60 Opening time (ms) 50 50 50 2500 2500 10.000 10.000 10.000 40 31.5 31.5 Number of switching operations Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 3 Service temperature (°C) - 5 / + 40 - 5 / + 40 - 5 / + 40 Offer extension PE90437 PE90765 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-47 Medium Voltage Distribution PIX SF6 / FPX by FPX Original brand: ALSTOM PE90859 ECOFIT™ proposal With ECOFIT™, a true extended life time 1994 2014 2024 PE90857 FPX FPX ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90857 FPX Circuit Breaker Main technical characteristics FPX Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) FPX Circuit Breaker Up to 3150 A 40 kA 12 kV Up to 2500 A 31.5 kA 17.5 kV FPX Up to 2500 A 31.5 kA 24 kV FPX Technology SF6 SF6 SF6 Rated voltage Ur (kV) 12 17.5 24 Switching sequence O-3mn-CO-3mn-CO CO-0.3 s-CO-15 s-CO O-0.3 s-CO-3mn-CO Surge withstand voltage Up (kV) 75 95 125 Closing time (ms) 50 Nominal frequency (Hz) 50 - 60 50 - 60 50 - 60 Opening time (ms) 50 Rated current Ir (A) Up to 3150 Up to 2500 Up to 2500 Up to 40 Up to 31.5 Up to 31.5 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90859 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-48 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution PNX36 / HVX36 by HVX36 Original brand: AEG PE90819 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90818 1994 2015 HVX36 HVX36 ECOFIT™ solution Commercialisation End of commercialisation PE90650 HVX36 Circuit Breaker Main technical characteristics HVX36 Rated current (Ir) Intensity short circuit (Isc) Rated voltage Un (50/60 Hz) HVX36 Circuit Breaker 630 - 2500 A 25 - 31.5 kA 36 kV HVX36 Technology Vacuum Rated voltage Ur (kV) 36 HVX36 Switching sequence O-0.3 s-CO-3min-CO Surge withstand voltage Up (kV) 70 Closing time (ms) 45 - 63 Nominal frequency (Hz) 50 - 60 Opening time (ms) 35 - 53 Rated current Ir (A) 630 - 2500 10.000 Short circuit current Isc (kA) 25 - 31.5 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90819 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-49 Medium Voltage Distribution R / IMC - MC - FAL - IFAL - VA - VAA - IVA - BAL - ALF - AL - TG Original brand: AEG by VA - VAA - Contactor PE90554 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90555 1973 1985 1990 1999 2003 2007 2013 IMC - MC FAL - IFAL BAL - ALF - AL VA - VAA - IVA - TG IMC - MC - FAL - IFAL - VA - VAA - IVA - BAL - ALF - AL - TG Circuit Breaker End of cialisation IMC -MC Commercialisation VA - VAA - Contactor ECOFIT™ solution End of commercialisation PE90556 End of spare parts Main technical characteristics IMC - MC - FAL - IFAL - VA - VAA - IVA - BAL - ALF - AL - TG Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) VA - VAA Circuit Breaker 1250 - 4000 A 16 - 50 kA 12 - 36 kV VA - VAA - Contactor Technology Vacuum Rated voltage Ur (kV) 12 - 24 VA - VAA - Contactor Switching sequence O-0.3 s-CO-3min-CO Surge withstand voltage Up (kV) 75 - 125 Closing time (ms) 20 Nominal frequency (Hz) 50 - 60 Opening time (ms) 20 - 50 Rated current Ir (A) 630 - 3550 10.000 Short circuit current Isc (kA) 16 - 50 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90554 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-50 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution RSW/ RSW by LF - Evolis Original brand: GOST standard ECOFIT™ proposal PE91009 With ECOFIT™, a true extended life time <1980 2000 2012 RSW LF-Evolis ECOFIT™ solution Commercialisation End of commercialisation & End of spare parts PE91010 RSW Circuit Breaker Main technical characteristics RSW LF - Evolis Circuit Breaker Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) LF Evolis Technology SF6 Vacuum Rated voltage Ur (kV) 6 - 17.5 6 - 10 630 - 1250 A 25 -31.5 kA 6 - 10 kV LF Evolis Switching sequence O-0,3 c-C/O-15 c-C/O O-0,3 c-C/O-15 c-C/O 3 min 3 min Surge withstand voltage Up (kV) 60 - 75 60 - 75 Closing time (ms) < 65 < 65 Nominal frequency (Hz) 50 50 Opening time (ms) < 50 < 50 Rated current Ir (A) 630 - 1250 630 - 1250 20.000 25 - 31.5 25 - 31.5 Number of switching operations 10000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 25 / + 40 - 25 / + 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-51 Medium Voltage Distribution Siclad / MAG II by LF1 - LF2 Original brand: Ansaldo PE90580 ECOFIT™ proposal With ECOFIT™, a true extended life time 1969 1997 2009 PE90581 MAG II LF1 - LF2 ECOFIT™ solution Commercialisation MAG II Circuit Breaker End of commercialisation End of spare parts PE90582 Main technical characteristics MAG II Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) LF1 - LF2 Circuit Breaker MAG II - 6 - 250/400 MAG II - 10 - 500 MAG II - 15 - 6 - 300/350 630 - 1250 - 2000 A 20 - 48 kA 6 kV 630 - 1250 - 2000 A 20 - 28 kA 10 kV 630 - 1250 - 2000 A 12 - 30 kA 15 kV LF1 LF2* LF1 Technology SF6 SF6 Rated voltage Ur (kV) 7.2 - 12 7.2 - 12 - 17.5 Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO LF2* Surge withstand voltage Up (kV) 60 - 75 60 - 75 - 95 Closing time (ms) < 72 < 72 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) < 54 < 54 Rated current Ir (A) 630 - 1250 2000 10.000 10.000 - 25 / + 40 - 25 / + 40 Short circuit current Isc (kA) 31.5 40 Number of switching operations Short circuit duration Tk (s) 3 3 Service temperature (°C) * For Siclad panels 730mm & 850mm wide Offer extension PE90437 PE90580 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-52 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Solenarc DSE Metal-Clad switchgear / DSE by Magnum CB Original brand: Square D PE90539 ECOFIT™ proposal With ECOFIT™, a true extended life time <1975 1988 1999 2005 PE90540 DSE Magnum CB ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90541 DSE Circuit Breaker Main technical characteristics DSE Rated current (Ir) 3-phase MVA rating Rated voltage Un Magnum CB Circuit Breaker 1200 - 3000 A 250 MVA 5 kV 5MGSB 15MGSB Technology Vacuum Vacuum Rated voltage Ur (kV) 5 15 95 Surge withstand voltage Up (kV) 60 1200 - 3000 A 250 - 1000 MVA 15 kV 5MGSB 15MGSB Rated current Ir (A) 1200 1200 - 3000 3-phase rating (MVA) 250 250 - 1000 Interrupting time (ms) 100 60 Offer extension PE90437 PE90539 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-53 Medium Voltage Distribution Venus / GI - GL by LF1 - LF3 Nuova Magrini Galileo ECOFIT™ proposal With ECOFIT™, a true extended life time GI - GL Circuit Breaker 1989 2000 PE90583 PE90583 Original brand: 2008 2010 GI - GL LF1 - LF3 ECOFIT™ solution End of commercialisation End of spare parts PE90585 Commercialisation Main technical characteristics GI LF1 - LF3 Circuit Breaker GL Rated current (Ir) 630 - 1250 A 630 - 1250 A 1600 - 3150 A 1600 - 3150 A 1600 - 3150 A 1600 - 3150 A Short circuit current (Isc) Rated voltage Un (50/60 Hz) 12.5 - 31.5 kA 7 - 12 kV 12 - 25 kA 17 - 24 - 36 kV 50 kA 7 kV 20 - 40 kA 12 kV 20 - 40 kA 24 kV 20 - 31.5 kA 36 kV LF1 LF3 Technology SF6 SF6 Panel width (mm) 600 900 Rated voltage Ur (kV) 12 17.5 LF1 Switching sequence LF3 O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 75 125 Closing time (ms) < 72 < 72 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) < 54 < 54 Rated current Ir (A) 630 - 1250 1600 - 1250 10.000 10.000 Short circuit current Isc (kA) 31.5 50 Number of switching operations Short circuit duration Tk (s) 3 3 Service temperature (°C) - 25 / + 40 - 25 / + 40 Offer extension PE90437 PE90583 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-54 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution VISAX / BLV by BLV Original brand: GEC Alsthom PE90219 ECOFIT™ proposal With ECOFIT™, a true extended life time 1996 2015 2025 PE90865 BLV BLV ECOFIT™ solution Commercialisation End of commercialisation End of spare parts BLV Circuit Breaker PE90865 Main technical characteristics BLV Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) BLV Circuit Breaker 400 - 1250 A 16 - 40 kA 7.2 kV 400 - 1250 A 16 - 40 kA 12 kV BLV 400 - 1250 A 16 - 40 kA 17.5 kV BLV Technology SF6 SF6 SF6 SF6 Rated voltage Ur (kV) 7.2 12 17.5 24 Switching sequence O-3mn-CO-3mn-CO O-0.3 s-CO-3mn-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 125 125 125 125 Closing time (ms) 51 Nominal frequency (Hz) 50 - 60 50 - 60 50 - 60 Opening time (ms) 40 50 - 60 400 - 1250 A 16 - 31.5 kA 24 kV Rated current Ir (A) 400 - 1250 400 - 1250 400 - 1250 400 - 1250 16 - 40 16 - 40 16 - 40 16 - 31.5 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 3 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90219 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-55 Medium Voltage Distribution VM6 DM12 / FB4 by SF1 Original brand: Merlin Gerin PE90421 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90422 1975 1993 2009 2010 FB4 SF1 ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90423 FB4 Circuit Breaker Main technical characteristics FB4 SF1 Circuit Breaker Rated current (Ir) 400 - 1250 A 400 - 1250 A 400 - 1250 A 400 - 1250 A Short circuit current (Isc) Rated voltage Un (50/60 Hz) 12.5 - 31.5 kA 7.2 kV 12.5 - 25 kA 12 kV 12.5 - 20 kA 17.5 kV 12.5 - 20 kA 24 kV SF1 Technology SF6 Rated voltage Ur (kV) Up to 24 SF1 Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) Up to 125 Closing time (ms) < 65 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 50 Rated current Ir (A) 400 - 1250 10.000 Short circuit current Isc (kA) 12.5 - 25 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90421 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-56 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution VMX / VMX by VMX Original brand: GEC Alstom PE90692 ECOFIT™ proposal With ECOFIT™, a true extended life time 1987 2004 PE90764 VMX VMX ECOFIT™ solution Commercialisation PE90764 VMX Circuit Breaker End of commercialisation Main technical characteristics VMX Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) VMX Circuit Breaker 630 - 2000 A Up to 25 kA/3s 11 kV VMX Technology Vacuum Rated voltage Ur (kV) 11 VMX Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 95 Closing time (ms) < 52 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 61 Rated current Ir (A) 630 - 1250 25 Number of switching operations 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90692 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-57 Medium Voltage Distribution WBA / VA - VAA - ECA - BAL - AL by VA - VAA - Contactor Original brand: AEG PE90657 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90665 1989 2006 VA - VAA - ECA - BAL - AL VA - VAA - Contactor ECOFIT™ solution Commercialisation PE90666 VA - VAA - ECA - BAL - AL Circuit Breaker Main technical characteristics Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) VA - VAA Circuit Breaker BAL - AL VAA ECA VA 250 A 20 kA 3.6 - 12 kV 630 - 1250 A 16 - 25 kA 12 - 24 kV 630 - 2500 A 20 - 50 kA 12 - 24 kV 630 - 2500 A 20 - 50 kA 12 - 38 kV VA - VAA - Contactor Technology Vacuum Rated voltage Ur (kV) 12 - 24 VA - VAA - Contactor Switching sequence O-0.3 s-CO-3 s-CO Surge withstand voltage Up (kV) 75 - 125 Closing time (ms) 20 Nominal frequency (Hz) 50 - 60 Opening time (ms) 20 - 50 Rated current Ir (A) 630 - 2500 10.000 Short circuit current Isc (kA) 25 - 31.5 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90658 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-58 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution WBB / VA - VAA - ECA - BAL - AL by VA - VAA - Contactor Original brand: AEG PE90659 ECOFIT™ proposal With ECOFIT™, a true extended life time 1994 2004 2013 2014 PE90663 BAL - AL ECA VA - VAA VAA ECOFIT™ solution VA - VAA - ECA - BAL - AL Circuit Breaker PE90664 Commercialisation End of commercialisation End of spare parts Main technical characteristics Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) VA - VAA Circuit Breaker BAL - AL VAA ECA VA 250 A 20 kA 3.6 - 12 kV 630 - 1250 A 16 - 25 kA 12 - 24 kV 630 - 2500 A 20 - 50 kA 12 - 24 kV 630 - 2500 A 20 - 50 kA 12 - 38 kV VA - VAA - Contactor Technology Vacuum Rated voltage Ur (kV) 12 - 15 VA - VAA - Contactor Switching sequence O-0.3 s-CO-3 s-CO Surge withstand voltage Up (kV) 75 - 95 Closing time (ms) 20 Nominal frequency (Hz) 50 - 60 Opening time (ms) 20 - 50 Rated current Ir (A) 630 - 2500 10.000 Short circuit current Isc (kA) 25 - 31.5 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90660 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-59 Medium Voltage Distribution WBD / VAA - VA - HVX by VAA - VA Original brand: AEG PE90820 ECOFIT™ proposal With ECOFIT™, a true extended life time 1992 2015 VA - VAA - HVX PE90663 VA - VAA ECOFIT™ solution Commercialisation PE90821 VA - VAA - HVX Circuit Breaker End of commercialisation Main technical characteristics VA - VAA - HVX Rated current (Ir) Intensity short circuit (Isc) Rated voltage Un (50/60 Hz) VA - VAA Circuit Breaker 630 - 2500 A 25 - 31.5 kA 36 kV VA - VAA Technology Vacuum Rated voltage Ur (kV) 12 VA - VAA Switching sequence O-0.3 s-CO-3min-CO Surge withstand voltage Up (kV) 80 Closing time (ms) 20 Nominal frequency (Hz) 50 - 60 Opening time (ms) 20 - 50 Rated current Ir (A) 630 - 3150 10.000 Short circuit current Isc (kA) 25 - 31.5 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90820 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-60 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution WK (C/E/B/A) / VA - MC - BAL by VA - VAA - Contactor Original brand: AEG PE90661 ECOFIT™ proposal With ECOFIT™, a true extended life time PE90661 1987 2003 2013 MC BAL VA VA - VAA - Contactor ECOFIT™ solution VA - MC -BAL PE90650 Commercialisation End of commercialisation End of spare parts Main technical characteristics VA - MC - BAL Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) VA - VAA - Contactor 630 - 2500 A 31.5 - 50 kA Up to 24 kV VA - VAA - Contactor Technology Vacuum Rated voltage Ur (kV) 3.6 - 24 VA - VAA - Contactor Switching sequence O-0.3 s-CO-3 s-CO Surge withstand voltage Up (kV) 60 - 110 Closing time (ms) 20 Nominal frequency (Hz) 50 - 60 Opening time (ms) 20 - 50 Rated current Ir (A) 400 - 4000 10.000 Short circuit current Isc (kA) 10 - 50 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 5 / + 40 Offer extension PE90437 PE90661 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-61 Medium Voltage Distribution YSF6 / YSF6 by YSF6 Evolis Original brand: Yorkshire Switchgear PE90607 ECOFIT™ proposal With ECOFIT™, a true extended life time 1981 2001 2004 2021 PE90608 YSF6 YSF6 Evolis ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90609 YSF6 Circuit Breaker Main technical characteristics YSF6 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) YSF6 EVOLIS Circuit Breaker 630 - 1250 A Up to 25 kA 12 kV YSF6 Evolis Technology Vacuum Rated voltage Ur (kV) 11 YSF6 Evolis Switching sequence O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 75 Closing time (ms) < 50 Nominal frequency (Hz) 50 - 60 Opening time (ms) < 65 Rated current Ir (A) 630 - 1250 10.000 Short circuit current Isc (kA) 25 Number of switching operations Short circuit duration Tk (s) 3 Service temperature (°C) - 25 / + 40 Offer extension PE90437 PE90607 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-62 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution AHA panel by AHA panel Original brand: AEG - Alsthom - Alstom ECOFIT™ proposal PE91041 With ECOFIT™, a true extended life time 1997 2005 2012 AHA AHA ECOFIT™ solution Commercialisation End of commercialisation End of spare parts AHA Main technical characteristics AHA Rated current (Ir) Intensity short circuit (Isc) Rated voltage Un (50/60 Hz) 630 - 1250 A 25 - 31.5 kA 12 - 17.5 kV AHA Rated insulation level (kV) AHA 12 - 17.5 Rated current of busbar (A) 1250 Rated power frequency 38 withstand voltage/1mn (kVrms) Rated short time withstand current (3s) (kA) 25 - 31.5 Lightning impulse withstand voltage (peak value) (kVp) 95 Internal Arc Classification 31.5 (1s) (AFLR) Overall dimensions (wxhxd) (mm) 700x2330x1450 Ingress Protection degree Enclosure IP42 - Compartment IP2X (IP) Offer extension PE90437 PE91041 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-63 Medium Voltage Distribution DNF7 panel by DNF7 panel Original brand: Alsthom PE90748 ECOFIT™ proposal With ECOFIT™, a true extended life time 1983 2013 2014 DNF7 DNF7 ECOFIT™ solution Commercialisation End of commercialisation DNF7 Main technical characteristics DNF7 Rated current (Ir) Intensity short circuit (Isc) Rated voltage Un (50/60 Hz) 400 - 2000 A 31.5 kA 36 kV DNF7 Rated insulation level (kV) DNF7 36 Rated current of busbar (A) 400 - 1250 (2500***) Rated power frequency 70 withstand voltage/1mn (kVrms) Rated short time withstand current (4s) (kA) 16 - 31.5 Lightning impulse withstand voltage (peak value) (kVp) 170 Internal Arc Classification 25 kA (0.2s) (AFLR) Overall dimensions (wxhxd) (mm) 1300x2250*x2300** Ingress Protection degree Enclosure IP3X (IP) * 2900 mm with busbar compartment - ** 2500 mm with internal arc withstand, 2750 mm with cables voltage compartment - *** With forced cooling (on request) Offer extension PE90437 PE90748 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-64 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Fluair F100-200 panel by Fluair F100-200 panel Original brand: Merlin Gerin ECOFIT™ proposal PE90409 With ECOFIT™, a true extended life time 1980 1998 F100-200 F100-200 ECOFIT™ solution Commercialisation End of commercialisation F100/200 Main technical characteristics Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) F100 F200 630 - 3150 A 25 - 50 kA 7.2 kV 630 - 3150 A 25 - 50 kA 12 - 17.5 kV F100-200 Rated insulation level (kV) F100-200 7.2 - 12 - 17.5 Rated current of busbar (A) Up to 3150 Rated power frequency 20 - 28 - 38 withstand voltage/1mn (kVrms) Rated short time withstand current (3s) (kA) Up to 50 Lightning impulse withstand voltage (peak value) (kVp) 60 - 75 - 95 Internal Arc Classification (1s) (AFLR) Overall dimensions (wxhxd) (mm) ≤1250A: 650x2100x1455/1700 2500 - 3150A: 900x2100x1700 Ingress Protection degree Enclosure IP3X (IP) Offer extension PE90437 PE90677 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-65 Medium Voltage Distribution PIX panel by PIX panel Original brand: Alstom PE90217 ECOFIT™ proposal With ECOFIT™, a true extended life time PIX PIX ECOFIT™ solution Commercialisation End of commercialisation PIX Main technical characteristics PIX Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) Up to 3150 A 40 kA/3s 12 kV Up to 2500 A 31.5 kA/3s 17.5 kV PIX Rated insulation level (kV) 12 Up to 2500 A 31.5 kA/3s 24 kV PIX 17.5 24 Rated current of busbar (A) Up to 3150 Up to 2500 Up to 2500 Rated power frequency 28 withstand voltage/1mn (kVrms) 38 50 Rated short time withstand current (3s) (kA) 40 31.5 31.5 Lightning impulse withstand voltage (peak value) (kVp) 75 95 125 Internal Arc Classification 40 (1s) (AFLR) 40 40 Overall dimensions (wxhxd) (mm) 1000x2130x1405 - 1000x2330x1605 1000x2330x1605 Ingress Protection degree IP3X (IP) IP3X IP3X * With forced cooling (on request) Offer extension PE90437 PE90217 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-66 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution PNX36 panel by PNX36 panel Original brand: Areva PE90819 ECOFIT™ proposal With ECOFIT™, a true extended life time 2009 2015 PNX36 PNX36 ECOFIT™ solution Commercialisation End of commercialisation PNX36 Main technical characteristics PNX36 Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) 630 - 2500 A 10 - 25 kA 36 kV PNX36 Rated insulation level (kV) PNX36 36 Rated current of busbar (A) 630 - 2500* Rated power frequency 70 withstand voltage/1mn (kVrms) Rated short time withstand current (4s) (kA) 82 Lightning impulse withstand voltage (peak value) (kVp) 170 Internal Arc Classification Arcing due to internal fault according to (1s) (AFLR) IEC 60298, 31.5 kA 1s, Type of accessibility A Overall dimensions (wxhxd) (mm) 120x2500x1600 Ingress Protection degree (IP) * With forced cooling (on request) Offer extension PE90437 PE90819 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-67 Medium Voltage Distribution PX12-24 panel by PX12-24 panel Original brand: Alstom PE90677 ECOFIT™ proposal With ECOFIT™, a true extended life time 1993 1997 PX12-24 PX12-24 ECOFIT™ solution Commercialisation End of commercialisation PX12-24 Main technical characteristics Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) PX12 PX24 400 - 3150 A 25 - 40 kA 12 kV 400 - 2500 A 16 - 25 - 31.5 kA 24 kV PX12 PX24 PX12 PX24 12 24 Rated current of busbar (A) 630 - 3150 630 - 2500 Rated power frequency 28 withstand voltage/1mn (kVrms) 50 Rated short time withstand current (3s) (kA) 25 - 40 25 - 31.5 Lightning impulse withstand voltage (peak value) (kVp) 75 125 Internal Arc Classification 25 (1s) (AFLR) Overall dimensions (mm) (W x H x D) <1250A: 650x2135x1320 ≤2000A: 750x2135x1320 Ingress Protection degree Enclosure IP3X ≤2000A: 750x2135x1320 >2000A: 900x2335x1570 (IP) >2000A: 900x2135x1320 Rated insulation level (kV) 25 Enclosure IP3X Offer extension PE90437 PE90677 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-68 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution R panel by R panel Original brand: AEG PE90655 ECOFIT™ proposal With ECOFIT™, a true extended life time 1973 1990 1999 2000 R R ECOFIT™ solution Commercialisation End of commercialisation End of spare parts R Main technical characteristics R Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) 400 - 2500 A Up to 40 kA/3s 12 kV 400 - 2500 A Up to 25 kA/3s 24 kV R Rated insulation level (kV) R 12 - 24 Rated current of busbar (A) 630 - 3350 Rated power frequency 28 - 50 withstand voltage/1mn (kVrms) Rated short time withstand current (4s) (kA) 40 - 125 Lightning impulse withstand voltage (peak value) (kVp) 75 - 125 Internal Arc Classification PEHLA (1s) (AFLR) Overall dimensions (wxhxd) (mm) 700, 800, 1000, 1400, 1600x2330, 2420x1100, 1250, 1300, 1450 Ingress Protection degree Standard IP2X (IP) On request IP3X, IP4X Offer extension PE90437 PE90655 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-69 Medium Voltage Distribution VISAX panel by VISAX panel Original brand: GEC Alstom PE90219 ECOFIT™ proposal With ECOFIT™, a true extended life time 1996 2015 2029 VISAX VISAX ECOFIT™ solution Commercialisation End of spare parts VISAX Main technical characteristics VISAX Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) Up to 2500 A 25 kA/3s 12 kV Up to 2500 A 25 kA/3s 17.5 kV VISAX Rated insulation level (kV) 12 Up to 2500 A 25 kA/3s 24 kV VISAX 17.5 24 Rated current of busbar (A) Up to 2500 Up to 2500 Up to 2500 Rated power frequency 28 withstand voltage/1mn (kVrms) 38 50 Rated short time withstand current (3s) (kA) 25 25 25 Lightning impulse withstand voltage (peak value) (kVp) 75 95 125 Internal Arc Classification 25 (1s) (AFLR) 25 25 Overall dimensions (wxhxd) (mm) 800 - 1100x2150 - 2650x1250 - 1540 Ingress Protection degree IP3X - IP4X (IP) IP3X - IP4X IP3X - IP4X * With forced cooling (on request) Offer extension PE90437 PE90219 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-70 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution VMX panel by VMX panel Original brand: GEC Alstom PE90692 ECOFIT™ proposal With ECOFIT™, a true extended life time 1987 2004 VMX VMX ECOFIT™ solution Commercialisation End of commercialisation VMX Main technical characteristics VMX Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) 630 - 2000 A Up to 25 kA/3s 11 kV VMX Rated insulation level (kV) VMX 12 Rated current of busbar (A) Up to 2000 Rated power frequency 28 - 35 withstand voltage/1mn (kVrms) Rated short time withstand current (4s) (kA) Up to 26.3 Lightning impulse withstand voltage (peak value) (kVp) 75 Internal Arc Classification 25 (3s) (AFLR) Overall dimensions (wxhxd) (mm) 606 - 540x2000 - 2000x1867 - 1360 Ingress Protection degree IP3X (IP) * With forced cooling (on request) Offer extension PE90437 PE90692 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-71 Medium Voltage Distribution WBA panel by WBA panel Original brand: AEG ECOFIT™ proposal PE90657 With ECOFIT™, a true extended life time 1989 2006 WBA WBA ECOFIT™ solution Commercialisation WBA End of commercialisation Main technical characteristics WBA Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) 630 - 2500 A 16 - 25 kA & 20 - 50 kA 12 - 24 kV WBA Rated insulation level (kV) 630 - 2500 A 20 - 50 kA 12 - 38 kV WBA 12 - 24 Rated current of busbar (A) 630 - 2500 Rated power frequency 28 - 50 withstand voltage/1mn (kVrms) Rated short time withstand current (4s) (kA) 63 - 80 Lightning impulse withstand voltage (peak value) (kVp) 75 - 125 Internal Arc Classification PEHLA 31.5 kA (1s) (AFLR) Overall dimensions (wxhxd) (mm) 600/800/1000x2330x1250/1300 Ingress Protection degree Standard IP2X (IP) On request IP3X, IP4X Offer extension PE90437 PE90658 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-72 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution WBB panel by WBB panel Original brand: AEG ECOFIT™ proposal PE90659 With ECOFIT™, a true extended life time 1990 2006 WBB WBB ECOFIT™ solution Commercialisation End of commercialisation WBB Main technical characteristics WBB Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) 630 - 2500 A 20 - 50 kA 12 - 24 - 38 kV WBB Rated insulation level (kV) WBB 12 - 15 Rated current of busbar (A) 630 - 2500 Rated power frequency 28 - 38 withstand voltage/1mn (kVrms) Rated short time withstand current (4s) (kA) 63 - 80 Lightning impulse withstand voltage (peak value) (kVp) 75 - 95 Internal Arc Classification PEHLA 31.5 kA (1s) (AFLR) Overall dimensions (wxhxd) (mm) 600, 800, 1000x2330x1250, 1500 Ingress Protection degree Standard IP2X (IP) On request IP3X, IP4X Offer extension PE90437 PE90660 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-73 Medium Voltage Distribution WBD panel by WBD panel Original brand: AEG PE90820 ECOFIT™ proposal With ECOFIT™, a true extended life time 1992 2015 WBD WBD ECOFIT™ solution Commercialisation End of commercialisation WBD Main technical characteristics WBD Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) 630 - 3150 A 80 kA 12 kV WBD Rated insulation level (kV) WBD 12 Rated current of busbar (A) 630 - 3150* Rated power frequency 28 withstand voltage/1mn (kVrms) Rated short time withstand current (4s) (kA) 80 Lightning impulse withstand voltage (peak value) (kVp) 80 Internal Arc Classification PEHLA 31.5 kA (1s) (AFLR) Overall dimensions (wxhxd) (mm) 600, 800x3000x1750 Ingress Protection degree IP 2X even for open door and modul in (IP) disconnecting position, IP 3X to the busbar, outside IP 52 possible * With forced cooling (on request) Offer extension PE90437 PE90820 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or A-74 MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution WK panel by WK panel Original brand: AEG ECOFIT™ proposal PE90661 With ECOFIT™, a true extended life time 1987 2003 WK WK ECOFIT™ solution Commercialisation End of commercialisation WK Main technical characteristics WK Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) 630 - 2500 A 20 - 50 kA/3s 12 - 24 - 38 kV WK Rated insulation level (kV) WK 3.6 - 24 Rated current of busbar (A) 630 - 4000 Rated power frequency 28 - 38 withstand voltage/1mn (kVrms) Rated short time withstand current (4s) (kA) 63 - 80 Lightning impulse withstand voltage (peak value) (kVp) 110 Internal Arc Classification PEHLA 31.5 kA (1s) (AFLR) Overall dimensions (wxhxd) (mm) 600/1060x2330x1700/2100 Ingress Protection degree Standard IP2X (IP) On request IP3X, IP4X Offer extension PE90437 PE90661 Energy management: replacement of the old protection relay (Schneider Electric or competitors) Sepam series 10, 20, 40, 60 , 80 PE90488 or MICOMP series 10, 20, 30, 40 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-75 Medium Voltage Distribution Cradle to Cradle / All breaker types Withdrawable CB by Evolis MC cassette Original brand: All ECOFIT™ proposal All breaker types Compatible with all open Air Insulated Switchgear legacy and no legacy cubicles with minimum inside panel width ≥ 560 mm With ECOFIT™, a true extended life time PE57994 This solution consist in fitting a cradle inside an existing panel. - It is particularly adapted for non Schneider Installed Base. - ECOFIT™ solution with shutters and mechanical interlocks embedded. - Only the fixed connections (between the cradle and existing busbar) are customized. - Only the width of the existing panel has to be considered. Main technical characteristics All types Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) Evolis Circuit Breaker 630 - 1250 A Up to 31.5 kA 7.2 - 12 kV 630 - 2500 A Up to 40 kA 7.2 - 12 - 17.5 kV Evolis MC1 MC2 MC3 Evolis MC1 Technology Vacuum Vacuum Vacuum Switching sequence Rated voltage Ur (kV) 7.2 - 12 7.2 - 12 - 17.5 7.2 - 12 - 17.5 O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 60 - 75 60 - 75 - 95 60 - 75 - 95 Closing time (ms) < 65 < 65 < 65 Nominal frequency (Hz) 50 - 60 50 - 60 50 - 60 Opening time (ms) < 50 < 50 < 50 Rated current Ir (A) 630 - 1250 630 - 1250 630 - 2500 Up to 31.5 Up to 40 Up to 40 Number of switching operations 2.000 (for Isc= 40 kA class M1) - 10.000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 1 Service temperature (°C) - 25 / + 40 240 240 550 DE57194EN 285 H 805 370 Weight (kg) 300 W A-76 Cassette Phase to phase (mm) Dimensions (mm) 321 611 D E W H D MC2 - 25 / + 40 MC3 - 25 / + 40 MC1 MC2 MC3 145 556 980 1223 222 185 686 980 1223 255 240 886 980 1223 326 100 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium Voltage Distribution Cradle to Cradle / All breaker types Withdrawable CB by F400 cassette Original brand: All ECOFIT™ proposal All breaker types Compatible with all open Air Insulated Switchgear legacy and no legacy cubicles with minimum inside panel width ≥ 1105 mm With ECOFIT™, a true extended life time DE57396 This solution consist in fitting a cradle inside an existing panel. - It is particularly adapted for non Schneider Installed Base. - ECOFIT™ solution with shutters and mechanical interlocks embedded. - Only the fixed connections (between the cradle and existing busbar) are customized. - Only the width of the existing panel has to be considered. Main technical characteristics All types Rated current (Ir) Short circuit current (Isc) Rated voltage Un (50/60 Hz) F400 Circuit Breaker 1250 - 2500 A Up to 40kA 24 - 36 kV F400 - SF F400 cassette Technology SF6 SF6 Rated voltage Ur (kV) 24 - 36 40.5 1250 A Up to 31.5 kA 40.5 kV F400 - SF F400 cassette Switching sequence O-3 min-CO-3 min-CO O-3 min-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-3 min-CO O-0.3 s-CO-15 s-CO O-0.3 s-CO-15 s-CO Surge withstand voltage Up (kV) 125 - 170 185 Closing time (ms) < 65 < 65 Nominal frequency (Hz) 50 - 60 50 - 60 Opening time (ms) < 50 < 50 Rated current Ir (A) 1250 - 2500 1250 10000 25 - 40 31.5 Number of switching operations 10000 Short circuit current Isc (kA) Short circuit duration Tk (s) 3 3 Service temperature (°C) - 25 / + 40 - 25 / + 40 PE57431 Cassette Dimensions (mm) Weight (kg) A B C 1250 A 2500A - 3000 A 738 540 2030 750 752 533 2030 850 New panel technical characteristics Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 A-77 Low Voltage Distribution Low Voltage Distribution Contents LV Circuit Breaker or Contactor B Control Compact C801-C1251 DA DS H Series Masterpact M SE Selpact Unelec CNP Visucompact CM Associated offers Energy Management Associated offers Source-changeover systems B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12 B-12 LV Drawer T140 MB400 Offer Extension Drawer components Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 B-13 B-14 B-15 B-1 Low Voltage Distribution B Control by Masterpact NT - NW Original brand: Nuova Magrini Galileo ECOFIT™ proposal PE90573 With ECOFIT™, a true extended life time 1972 1990 2005 2009 B Control (B1-35/B1-50/B3-50/B3-75/B3-90/B4-100) Masterpact NT - NW B Control Circuit Breaker ECOFIT™ solution End of commercialisation End of spare parts PE90574 Commercialisation Main technical characteristics Masterpact NW Circuit Breaker Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Ultimate breaking capacity (kA rms, 220/415V AC 50/60Hz) Icu B Control Masterpact NT - NW 660 V 800 - 4000 A 32 - 100 kA 690 V 800 - 4000 A 42 - 150 kA PE90574 B Control ECOFIT™ solution The ECOFIT™ B Control solution enables to benefit from all the enhanced features of Masterpact NT or NW circuit breakers and accessories. Active Energy Management™ programme that includes an energy metering system • Identify the device, • Indicate status conditions, • Control the device (with communication auxiliaries) • Setting of the protection and alarm functions. B-2 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Low Voltage Distribution Compact C801 - C1251 by Compact NS800 - NS1250 Original brand: Merlin Gerin With ECOFIT™, a true extended life time PE90572 PE90430 ECOFIT™ proposal 1993 2007 2009 Compact C801 - C1251 Compact NS800 - NS1251 C801 - C1251 Circuit Breaker ECOFIT™ solution PE90431 Commercialisation End of commercialisation End of spare parts Main technical characteristics Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Ultimate breaking capacity (kA rms, 220/415V AC 50/60Hz) Icu NS801 - NS1251 Circuit Breaker Compact C801 - C1251 Compact NS800 - NS1251 690 V 800 - 1250 A 50 - 150 kA 690 V 800 - 1250 A 50 - 150 kA Compact C801 - C1251 ECOFIT™ solutions DE90252 Plug & Play The ECOFIT™ Compact Plug & Play solution lets you retrofit the latest generation of Compact NS circuit breakers in the existing Compact C chassis with very short onsite servicing times. Solution available for withdrawable type only, 3p & 4p, 800A to 1250A. PE90257 PE90256 Compactkit 1 Removal 2 Replacement The ECOFIT™ Compactkit solution enables to benefit from all the enhanced features of Compact NS circuit breakers and accessories. It requires total shutdown of the installation to access the busbars. Solution available for fixed type, 3p & 4p, 800A to 1250A. PE90571 DB402068 Active Energy Management™ programme that includes an energy metering system • Identify the device, • Indicate status conditions, • Control the device (with communication auxiliaries) • Setting of the protection and alarm functions. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 B-3 Low Voltage Distribution DA (DSA1 - DNA1 - DSA2 - DNA2 - DRA - DNAH) Original brand: Merlin Gerin by MASTERPACT NW08 -NW63 ECOFIT™ proposal PE90424 With ECOFIT™, a true extended life time 1986 1986 1997 1998 DA (DSA1 - DNA1 - DSA2 - DNA2 - DRA - DNAH) DA Circuit Breaker Masterpact NW ECOFIT™ solution PE90427 Commercialisation End of commercialisation End of spare parts Main technical characteristics Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Ultimate breaking capacity (kA rms, 220/415V AC 50/60Hz) Icu Masterpact NW Circuit Breaker DA Masterpact NW 660 V 630 - 6300 A 42 - 100 kA 690 V 800 - 6300 A 42 - 150 kA DA ECOFIT™ solution PE90427 The ECOFIT™ DA solution enables to benefit from all the enhanced features of Masterpact NW circuit breakers and accessories. It requires total shutdown of the installation to access the busbars. The kit solution (including circuit breaker) is available for fixed and withdrawable types, 3p & 4p, 630 to 6300A. B-4 PE90571 DB402068 Active Energy Management™ programme that includes an energy metering system • Identify the device, • Indicate status conditions, • Control the device (with communication auxiliaries) • Setting of the protection and alarm functions. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Low Voltage Distribution DS by Masterpact NT - NW Original brand: Square D, Westinghouse ECOFIT™ proposal PE90537 With ECOFIT™, a true extended life time 1983 1998 2007 2013 DS (DS206 - DS416S/H - DS420 - DS308/508/608 - DS516/616/620) Masterpact NT - NW DS Circuit Breaker ECOFIT™ solution End of commercialisation End of spare parts PE90249 Commercialisation Main technical characteristics Masterpact NT - NW Circuit Breaker Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Ultimate breaking capacity (kA rms, 600V AC 50/60Hz) Icu DS Masterpact NT - NW 600 V 800 - 2000 A 42 - 65 kA 600 V 800 - 2000 A 42 - 65 kA DS ECOFIT™ solution PE90249 The ECOFIT™ DS solutions fixed or draw-out types enable to benefit from all the enhanced features of Masterpact NT or NW circuit breakers and accessories. PE90571 DB402068 Active Energy Management™ programme that includes an energy metering system • Identify the device, • Indicate status conditions, • Control the device (with communication auxiliaries) • Setting of the protection and alarm functions. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 B-5 Low Voltage Distribution H Series by Masterpact NT - NW Original brand: Federal Pioneer PE90615 ECOFIT™ proposal With ECOFIT™, a true extended life time 1960 2001 2003 2013 H Series (H3 - HL3 - H2 - HL2 - 1000HF1) Masterpact NT - NW H Series Circuit Breaker ECOFIT™ solution End of commercialisation End of spare parts PE90616 Commercialisation Main technical characteristics Masterpact NT - NW Circuit Breaker Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Ultimate breaking capacity (kA rms, 600V AC 50/60Hz) Icu H Series Masterpact NT - NW 600 V 600 - 4000 A 30 - 200* kA 600 V 800 - 4000 A 30 - 200* kA * with fuse H Series ECOFIT™ solution PE90616 The ECOFIT™ H series solutions fixed or draw-out types enable to benefit from all the enhanced features of Masterpact NT or NW circuit breakers and accessories. B-6 PE90571 DB402068 Active Energy Management™ programme that includes an energy metering system • Identify the device, • Indicate status conditions, • Control the device (with communication auxiliaries) • Setting of the protection and alarm functions. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Low Voltage Distribution Masterpact M08 - M63 by Masterpact NW08 -NW63 Original brand: Merlin Gerin ECOFIT™ proposal 035928 With ECOFIT™, a true extended life time 1986 2003 2004 2013 Masterpact M Masterpact NW Masterpact M Circuit Breaker ECOFIT™ solution PE90249 Commercialisation End of commercialisation End of spare parts Main technical characteristics Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Ultimate breaking capacity (kA rms, 220/415V AC 50/60Hz) Icu Masterpact NW Circuit Breaker Masterpact M Masterpact NW 690 V 800 - 6300 A 40 - 150 kA 690 V 800 - 6300 A 42 - 150 kA Masterpact M ECOFIT™ solutions PE90452 Plug & Play The ECOFIT™ Masterpact Plug & Play solution lets you retrofit the latest generation of Masterpact NW circuit breakers in the existing Masterpact M chassis. Solution available for withdrawable type only, 3p & 4p, 800 A to 3200 A. PE90454 PE90453 Masterkit 1 Removal 2 Replacement The ECOFIT™ Masterkit solution enables to benefit from all the enhanced features of Masterpact NW circuit breakers and accessories without modifying the busbars. It requires total shutdown of the installation to access the busbars. Solution available for fixed and withdrawable types, 3p & 4p, 800 A to 6300 A. PE90571 DB402068 Active Energy Management™ programme that includes an energy metering system • Identify the device, • Indicate status conditions, • Control the device (with communication auxiliaries) • Setting of the protection and alarm functions. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 B-7 Low Voltage Distribution SE by Masterpact NW Original brand: Square D ECOFIT™ proposal PE90538 With ECOFIT™, a true extended life time 1983 2003 2010 2011 SE Masterpact NW SE Circuit Breaker ECOFIT™ solution End of commercialisation End of spare parts PE90435 Commercialisation Main technical characteristics Masterpact NW Circuit Breaker Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Ultimate breaking capacity (kA rms, 600V AC 50/60Hz) Icu SE Masterpact NW 600 V 1250 - 3000 A 100 kA 600 V 1250 - 3000 A 85 kA PE90435 SE ECOFIT™ solution The ECOFIT™ SE solutions fixed or draw-out types enable to benefit from all the enhanced features of Masterpact NT or NW circuit breakers and accessories. Active Energy Management™ programme that includes an energy metering system • Identify the device, • Indicate status conditions, • Control the device (with communication auxiliaries) • Setting of the protection and alarm functions. B-8 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Low Voltage Distribution Selpact by Masterpact NT-NW Original brand: Merlin Gerin ECOFIT™ proposal PE90428 With ECOFIT™, a true extended life time 1973 1989 1997 2009 Selpact (DN2 - DS2 - DR2 - DRS2) Masterpact NT-NW Selpact Circuit Breaker ECOFIT™ solution End of commercialisation End of spare parts PE90426 Commercialisation Main technical characteristics Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Ultimate breaking capacity (kA rms, 220/415V AC 50/60Hz) Icu Masterpact NW Circuit Breaker Selpact Masterpact NT-NW 660 V 630 - 3200 A 42 - 100 kA 690 V 800 - 3200 A 42 - 100 kA Selpact ECOFIT™ solution PE90426 The ECOFIT™ Selpact solutions enable to benefit from all the enhanced features of Masterpact NT or NW circuit breakers and accessories. Plug & Play The Plug&Play solution is available for withdrawable type only, 3p & 4p, 630 to 1600 A. Kit The kit solution (including circuit breaker) is available for fixed and withdrawable types, 3p & 4p, 630 to 3200 A. PE90571 DB402068 Active Energy Management™ programme that includes an energy metering system • Identify the device, • Indicate status conditions, • Control the device (with communication auxiliaries) • Setting of the protection and alarm functions. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 B-9 Low Voltage Distribution Unelec CNP by Masterpact NW Original brand: Unelec - Areva ECOFIT™ proposal PE90432 With ECOFIT™, a true extended life time 1968 1986 2007 2009 CNP Masterpact NW CNP Circuit Breaker ECOFIT™ solution End of commercialisation End of spare parts PE90433 Commercialisation Main technical characteristics Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Ultimate breaking capacity (kA rms, 220/415V AC 50/60Hz) Icu Masterpact NW Circuit Breaker CNP Masterpact NW 660 V 1250 - 2000 A 36 - 100 kA 690 V 1250 - 2000 A 42 - 100 kA CNP ECOFIT™ solution PE90433 The ECOFIT™ CNP solution enables to benefit from all the enhanced features of Masterpact NW circuit breakers and accessories. The solution is suitable for fixed type and only for Normabloc 660 switchboard. B-10 PE90571 DB402068 Active Energy Management™ programme that includes an energy metering system • Identify the device, • Indicate status conditions, • Control the device (with communication auxiliaries) • Setting of the protection and alarm functions. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Low Voltage Distribution Visucompact CM by Masterpact NW Original brand: Merlin Gerin PE90434 ECOFIT™ proposal With ECOFIT™, a true extended life time 1985 2001 2005 2010 Visucompact CM Masterpact NW ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90435 Visu Compact CM Circuit Breaker Main technical characteristics Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Ultimate breaking capacity (kA rms, 220/415V AC 50/60Hz) Icu Masterpact NW Circuit Breaker Visucompact CM Masterpact NW 440 V 1250 - 2500 A 70 - 85 kA 690 V 1250 - 2500 A 42 - 100 kA Visucompact CM ECOFIT™ solution PE90435 The ECOFIT™ Visucompact solution enables to benefit from all the enhanced features of Masterpact NW circuit breakers and accessories. PE90571 DB402068 Active Energy Management™ programme that includes an energy metering system • Identify the device, • Indicate status conditions, • Control the device (with communication auxiliaries) • Setting of the protection and alarm functions. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 B-11 Low Voltage Distribution LV Circuit Breaker & Contactor - Associated offers Energy Management - Micrologic control units - Measurements and protections Available for ECOFIT™ solutions using Masterpact NT/NW and Compact NS Micrologic 2 5 6 7 Type A-E A-E-P-H A-E-P-H A-P-H Functions Long time + instantaneous Long time + short time + instantaneous Long time + short time + instantaneous + earth fault Long time + short time + instantaneous + earth leakage up to 3200A A: Current measurements, fault indications, display and current maximeter. Specificities: 6.0 provides earth fault protection (residual or Source Ground Return); 7.0 provides earth leakage protection. E: A + Instantaneous measurement of power and energy without earth leakage protection. P: A + Calculation of power and energy value, voltage measurement, and programmable protection H: P + Harmonics Energy Management - Communication Available for ECOFIT™ solutions using Masterpact NT/NW and Compact NS • Identify the device. • Indicate status conditions. • Control the device (with the communicating auxiliairies). • Setting of the protection and alarms functions. 1 24 V DC 7 1 Modbus network 2 CCM: Chassis Communication Module 3 Breaker Universal Logic Plug (ULP) cord 4 Breaker Communication Module (BCM) 5 Prefabricated wiring 6 Micrologic trip unit 7 FDM21 display 8 Line terminator 2 8 3 Compact NS or Masterpact NT or NW depending on the device 5 4 6 Source-changeover systems Available for DA, Selpact and Masterpact M ECOFIT™ solutions using Masterpact NT/NW B-12 Mechanical interlocking (2 types) Automatic controllers Using connecting rods or using cables IVE: Electrical interlocking BA or UA automatic controllers Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Low Voltage Distribution T140 drawers by T140 drawers Original brand: Merlin Gerin PE90687 ECOFIT™ proposal With ECOFIT™, a true extended life time 1975 1990 1998 PE90688 T140 drawers T140 drawers ECOFIT™ solution PE90685 T140 drawers Commercialisation End of commercialisation End of spare parts Main technical characteristics T140 drawers Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Number of modules T140 drawers T140 drawers 440 V 125 - 625 A 1 to 6 440 V 125 - 625 A 1 to 6 T140 drawers ECOFIT™ solution PE90685 The ECOFIT™ T140 drawer solution enables to benefit from all the enhanced features of latest technology devices. The drawer solutions are suitable for manual or electrical operations. T140 drawers ECOFIT™ solution - Drawer components 102873 • Motor control command and protections - Functional units. 107395 • Control command auxiliaries for all types of drawers. 107429 11601 054047 106167 LC1D12 102870 102870 PB103354 • Electrical distribution - Functional units (NSX range with Micrologic). Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 B-13 Low Voltage Distribution MB400 drawers by MB400 drawers Original brand: Merlin Gerin PE90689 ECOFIT™ proposal With ECOFIT™, a true extended life time 1991 2003 2013 PE90688 MB400 drawers MB400 drawers ECOFIT™ solution PE90685 MB400 drawers Commercialisation End of commercialisation End of spare parts Main technical characteristics MB400 drawers Rated operational voltage (V AC 50/60 Hz) Ue Rated current (A) In 40° C Number of modules MB400 drawers MB400 drawers 440 V 125 - 625 A 1 to 6 440 V 125 - 625 A 1 to 6 MB400 drawers ECOFIT™ solution PE90685 The ECOFIT™ MB400 drawer solution enables to benefit from all the enhanced features of latest technology devices. The drawer solutions are suitable for manual or electrical operations. MB400 drawers ECOFIT™ solution - Drawer components 102873 • Motor control command and protections - Functional units. 107395 • Control command auxiliaries for all types of drawers. 107429 111601 054047 106167 LC1D12 102870 102870 PB103354 • Electrical distribution - Functional units (NSX range with Micrologic). B-14 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Low Voltage Distribution LV Drawers - Associated offers Specific spare parts: for any spare parts request for the fixe part, please contact your local correspondant. Available for ECOFIT™ solutions using Masterpact NT/NW and Compact NS Drawer components • Electrical distribution – Functional units (NSX range) Micrologic 2.2 or 2.3 Type Functions LSI protection 5.2 or 5.3 6.2 or 6.3 A-E A-E LSI protection Ammeter Energy meter LSI protection Ammeter Energy meter A: Current measurements, fault indications, display and current maximeter. Specificities: 6.0 provides earth fault protection (residual or Source Ground Return); 7.0 provides earth leakage protection. E: A + Instantaneous measurement of power and energy without earth leakage protection. • Motor control command and protections – Functional units 1 component motor feeder 2 components motor feeder 3 components motor feeder Circuit breaker Contactor combination Thermomagnetic circuit breaker + Contactor Thermomagnetic circuit breaker or switch-disconnector fuse + Contactor + Thermal protection • Control command auxiliaries for all types of drawers Miniature circuit-breaker Protection auxiliary circuit Auxiliary relays Ground fault protection Push buttons and lights Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 B-15 Protection relays MV Protection relay Contents Protection relay upgrade benefits CO CDG DPU 445 HCB IAC KCGG 122 & 142 M range - MCGG 11, 21 & 22 M range relay - MCTI 39-40 MCGG 62 Sepam 2000 VIP - RM6+ VIP & Vigirex - Various equipment Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 C-2 C-3 C-4 C-5 C-6 C-7 C-8 C-9 C-10 C-11 C-12 C-13 C-14 C-1 MV Protection relay Protection upgrade benefits Improve the performance of your system with the latest technology in micro-processor based integrated relays. Why protection upgrade? By replacing solid state and older type electromechanical protection relays with technologically advanced multi-function microprocessor-based digital relays, the performance accuracy and longevity of your system can be significantly improved. With a number of different protection functions Schneider Electric's range of relays can provide a range of options to include metering; communication; event capture; monitoring and control. Units are self-diagnostic to provide enhanced reliability. It is normally possible to use the existing current and potential transformers and auxiliary digital relay inputs. Schneider Electric's application based approach makes it easy to select the appropriate relay for your needs. What are the benefits? Accuracy System protection at the current level reduces unnecessary outages and minimise stresses to equipment. Increased accuracy of measurement assists in cost allocation and understanding power demand requirements. High reliability from advanced self supervision systems. Flexibility The integrated functions of the relay allow for communications and control of the equipment either as a stand-alone unit or as part of networked systems. All components in the protection chain are referenced and interface rapidly. No constraints for integration in cubicles due to the compact size of the base unit. C-2 Ease of use Settings and adjustments are entered via the device's keypad and visually displayed. Reduced costs The amalgamation of functions into one self-diagnosing meter reduces expenditure and saves on space. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 MV Protection relay CO by MiCOM P111/115 Original brand: General Electric PE90866 ECOFIT™ proposal With ECOFIT™, a true extended life time 2011 CO MiCOM P111/115 CO Protection Relay ECOFIT™ solution PE90867 Commercialisation End of commercialisation End of spare parts Main technical characteristics CO MiCOM P111 & 115 Protection Relay MiCOM P111/115 Case FT-11 or FT 21 Fit FT-11 & FT 21 cutout Replacement Type - 1 for 3* with minimal rewiring Type Electromechanical Numerical Functionality Single phase overcurrent 3 phase + Ground overcurrent Power supply - 24 VDC - 250 VDC Communication - IEC 60870-5-103, Modbus RTU *1 ECOFIT™ P111/115 – CO9 solution could replace 3 single phase CO9 units. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 C-3 MV Protection relay CDG - CAG - CTMM - CTMFM by MiCOM P1x –P2x Original brand: Areva or older or Vamp 5x PE90881 ECOFIT™ proposal With ECOFIT™, a true extended life time CDG - CAG - CTM range relays MiCOM or Vamp ECOFIT™ solution CDG type Protection Relay PE90882 Commercialisation End of commercialisation End of spare parts Old relay models ECOFIT™ solutions CDG - CAG MiCOM P122/P123 CTMM - CTMFM MiCOM P211 CDG - CAG VAMP 50/52 Descrition Feeder protection relay (Modbus/IEC103) Motor protection relay (Modbus/IEC103) Feeder protection relay (IEC 61850) Main technical characteristics MiCOM P Protection Relay C-4 CDG - CAG - CTM range relays Case Based on 1 or 3 independent units Replacement Type - MiCOM or Vamp 20TE, 4U withdrawal case, mounted as plug and play solution into the existing DGC /CAG/ CTM range case 1 withdrawal relay for 3 individual units Type Electromechanical & induction disk relay type Numerical Functionality Selective earth & phase fault overcurrent 3 phase & earth overcurrent Frequency range Calibrated for 50 Hz or 60 Hz only 50 to 60 Hz +/- 20 % Communication - IEC 60870-5-103, ModBus Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 MV Protection relay DPU 445 by MiCOM P123 Original brand: ABB PE90872 ECOFIT™ proposal With ECOFIT™, a true extended life time 2011 DPU 445 MiCOM P123 DPU 445 Protection Relay ECOFIT™ solution PE90873 Commercialisation End of commercialisation End of spare parts Main technical characteristics DPU 445 MiCOM P123 Protection Relay MiCOM P123 Case DPU 445 Fit existing cutout Replacement Type - 1 for 1 with minimal rewiring Type Digital Numerical Functionality 3 phase feeder 3 phase + ground feeder overcurrent Power supply 24 VDC - 125 VDC Communication - 24 VDC - 250 VDC Courier, DNP 3.0, IEC 60870-5-103, ModBus RTU Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 C-5 MV Protection relay HCB by MiCOM P521 Original brand: ABB PE90870 ECOFIT™ proposal With ECOFIT™, a true extended life time 2009 HCB MiCOM P521 HCB Protection Relay ECOFIT™ solution PE90871 Commercialisation End of commercialisation Main technical characteristics MiCOM P521 HCB MiCOM P521 Protection Relay C-6 End of spare parts Case FT-42 Fit existing cutout Replacement Type - 1 for 1 with minimal rewiring Type Electromechanical Numerical Functionality 3 phase differential 3 phase differential Power supply - 24 VDC - 250 VDC Communication - IEC 60870-5-103, ModBus RTU Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 MV Protection relay IAC by MiCOM P122 Original brand: General Electric PE90868 ECOFIT™ proposal With ECOFIT™, a true extended life time 2011 IAC MiCOM P122 IAC Protection Relay ECOFIT™ solution PE90869 Commercialisation End of commercialisation End of spare parts Main technical characteristics MiCOM P122 Protection Relay IAC MiCOM P122 Fit S1, S2, L2 or M1 cutout Case S1, S2, L2 or M1 Replacement Type - 1 for 3* with minimal rewiring Type Electromechanical Numerical Functionality Single phase overcurrent 3 phase + Ground overcurrent Power supply - Communication - 24 VDC - 250 VDC Courier, DNP3.0, IEC 60870-5-103, ModBus RTU *1 ECOFIT™ P122 – IAC solution could replace 3 single phase IAC units. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 C-7 MV Protection relay KCGG 122 & 142 by MiCOM P123R Original brand: Areva PE90634 ECOFIT™ proposal With ECOFIT™, a true extended life time 1997 2010 2011 2012 KCGG 122 & 142 MiCOM P123R KCGG 122 & 142 Protection Relay ECOFIT™ solution End of commercialisation End of support PE90635 Commercialisation MiCOM P123R Protection Relay Main technical characteristics K range relay - KCGG 122 & 142 MiCOM P123R 20TE size flush mounting Case 20TE size flush mounting Installation Withdrawable case Withdrawable case Language English Multilanguage Communication KBus / Courier KBus / Courier, DNP3, IEC60870-5-103 Power supply 24 V / 125 VDC - 48 V / 250 VDC 24 V / 250 VDC - 48 V / 240 VDC Digital input supply 48 VDC only According to Power Supply (above) ECOFIT™ KCGG 122 & 142 upgrades: diagnosis + implementation/installation of a fully industrialised solution Improve the performance of your system with the latest technology in micro-processor based integrated relays. C-8 Full retrofit solution Sustainability •Replacement of the protection relay and optimised maintenance. •Access to spare parts, new communication protocols and software facilities. •Schneider Electric technical support and guarantee. Manufacturer expertise •Solution developed by our specialist engineers. •Enhanced performance. •Retrofit process optimised. •Installation warranted by the manufacturer. Consultancy and audit - Engineering solutions & optimisation Local support & assistance - Maintenance & refurbishment No mechanical or electrical impact on your installation. Implementation and site test within a very limited time. New features enabled: •Advanced HMI for local control functions. •Standard communication protocols (Modbus, IEC 60870-5-103, DNP3 or KBUS/Courier). •Monitoring & Automation facilities. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 MV Protection relay M range - MCGG 11, 21 & 22 by MiCOM P120H Original brand: Areva PE90752 ECOFIT™ proposal With ECOFIT™, a true extended life time < 1984 2010 2012 M range - MCGG 11, 21 & 22 MiCOM P120H MCGG 22 Protection Relay ECOFIT™ solution End of spare parts PE90635 Commercialisation MiCOM P120H Protection Relay Main technical characteristics M range relay - MCGG 11, 21 & 22 MiCOM P120H Case 20TE size flush mounting 20TE size flush mounting Installation Withdrawable case Withdrawable case Language English Multilanguage Communication KBus / Courier KBus / Courier, DNP3, IEC60870-5-103 Power supply 24 V / 125 VDC - 48 V / 250 VDC 24 V / 250 VDC - 48 V / 240 VDC Digital input supply 48 VDC only According to Power Supply (above) Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 C-9 MV Protection relay M range - MCTI 39-40 by MiCOM P821MF Original brand: Areva PE90751 ECOFIT™ proposal With ECOFIT™, a true extended life time 1984 2010 2012 M range - MCTI 39-40 MiCOM P821MF MCTI 39-40 Protection Relay ECOFIT™ solution End of spare parts PE90635 Commercialisation MiCOM P821MF Protection Relay C-10 Main technical characteristics M range relay - MCTI 39-40 MiCOM P821MF Case 20TE size flush mounting 20TE size flush mounting Installation Withdrawable case Withdrawable case Language English Multilanguage Communication KBus / Courier KBus / Courier, DNP3, IEC60870-5-103 Power supply 24 V / 125 VDC - 48 V / 250 VDC 24 V / 250 VDC - 48 V / 240 VDC Digital input supply 48 VDC only According to Power Supply (above) Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 MV Protection relay MCGG 62 by MiCOM P126 Original brand: Areva or older PE90874 ECOFIT™ proposal With ECOFIT™, a true extended life time < 1984 2010 2014 MCGG 62 MiCOM P126 MCGG 62 Protection Relay ECOFIT™ solution PE90875 Commercialisation End of commercialisation End of spare parts Main technical characteristics MCGG 62 MiCOM P126 Protection Relay MiCOM P126 Case Size 6 Fit existing cutout Replacement Type - 1 for 1 plug-and-play Type Static Numerical Functionality 3 phase overcurrent 3 phase + ground overcurrent Power supply 24 VDC - 125 VDC Communication - 24 VDC - 250 VDC DNP 3.0, IEC 60870-5-103, ModBus RTU Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 C-11 MV Protection relay Sepam 2000 by Sepam 60 - 80 series Original brand: Merlin Gerin PE90638 ECOFIT™ proposal With ECOFIT™, a true extended life time 1993 2006 2012 2015 Sepam 2000 Sepam 60 - 80 series Sepam 2000 Protection Relay ECOFIT™ solution PE90639 Commercialisation End of commercialisation End of spare parts Main technical characteristics Sepam serie 80 Sepam 2000 X M06, M07, M08, M14 Motor Application Sepam 60 - 80 series Protection Relay Sepam serie 60* X M02 to M05, M09, M11, M15, M16, M20 to M23 X S02, S03, S06 to S09 Sub-station Application X S01, S04, S05 Bus Bar Application X B02, B04, B07, B12 X B01, B03 X Transformer Application without temp measurement T01 to T03, T06, T07, T09, T10, T12 to T15, T17 to T19 Transformer Application with temp measurement T21, T22, T23, T26, T27, T29, T30, T32 to T35, T37 to T39 Generator Application G01 to G08, G12, G13, G15 to G18 X C02, C04, C06, C08 X X T04, T05, T11, T16 X X T24, T25, T31, T36 Capacitor bank Application Transformer Diff. Application X C01, C03 X D02, D22 * Sepam serie 80 will be proposed in case of customised Logipam on the original Sepam 2000 ECOFIT™ Sepam 2000 upgrades: diagnosis + implementation/installation of a fully industrialised solution C-12 2. Presentation of new ECOFIT™ S2000 PE90637 1. Disconnection of existing terminal blocks PE90637 Improve the performance of your system with the latest technology in micro-processor based integrated relays. No mechanical or electrical impact on your installation. Implementation and site test within a very limited time. New features enabled: •Advanced HMI for local control functions. •Standard communication protocols (Modbus, IEC 61850). •Monitoring & advanced graphical interface for automations and logics. Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 MV Protection relay RM6+ / VIP by VIP + ECOFIT™ kit Original brand: Merlin Gerin PE90567 ECOFIT™ proposal A true extended life time PE90568 1987 1998 2008 2012 VIP VIP VIP Protection relays ECOFIT™ solution Commercialisation End of commercialisation End of spare parts PE90570 Proposed substitution PE90569 RM6+ VIP 300LL Protection relays Phase overcurrent protection IDMT (Inverse Definite Minimum Time) VIP 11R VIP 300LL Phase overcurrent protection IDMT (Inverse Definite Minimum Time) VIP 12R VIP 300LL Phase overcurrent and earth-fault protection IDMT and DT IEC 60255 VIP 200 VIP 300LL Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 C-13 MV Protection relay Various equipment / VIP & Vigirex by VIP & Sepam Original brand: Merlin Gerin PE90835 ECOFIT™ proposal A true extended life time PE90568 1987 1998 2005* 2012 VIP & Vigirex VIP & Sepam VIP Protection relays Proposed substitution Commercialisation End of commercialisation End of spare parts * Depending on the range Proposed substitution PE90569 PE90835 Various equipments VIP 300LL Protection relays C-14 Phase overcurrent and Earth-fault protection IDMT and DT IEC 60255 VIP 200RMR VIP 300LH Sensitive earth-fault protection Vigirex RH110 Sepam series 10 Phase overcurrent protection IDMT VIP 13 VIP 30 - VIP 300 - TBC Phase overcurrent protection DT VIP 17 VIP 37 Phase overcurrent and Earth-fault protection IDMT and DT IEC 60255 VIP 200 VIP 300 Sensitive earth-fault VIP 50 Sepam series 10 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 MV Protection relay Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 C-15 Substation automation Substation Automation Contents Control System upgrade benefits BAY Controler BM9x00 PACIS OI PSCN3020 HMI SEEFOX HMI Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 D-2 D-3 D-4 D-5 D-6 D-1 Substation Automation Control System upgrade benefits Improve the performance of your system with the latest technology in micro-processor based integrated relays. Why Control Systems upgrade? Upgrade solutions intend to improve the performance of your control system with the latest technology in computers. This is also the opportunity to benefit from computer and OS upgrading to Windows 7 to get enhances performances and advanced features for the new HMI Considering the large variety of legacy control systems still in operation with limited extension and maintenance facilities, these Ecofit solutions provide an opportunity to benefit of a unique HMI software and standard communication protocol based on IEC61850. What are the benefits? Ready for future extensions Enables smooth and consistent legacy Control System solutions modernization. Open, flexible and scalable architecture facilitating aggregation of several systems at substation level. Easiness for future extensions. Ease of use Fast implementing without substation shut down, original control systems can remain in operation in most of cases No modification of existing communication network protocol (Modbus TCP or IEC 61850, as well as protective relays communication protocol) . This could be done step by step in further stages. Enhance graphical features Realtime trends of analog values as tooltip Zoom in/ Zoom out Monitoring facilities by color bar graph status easy implementation Costs reduction Cost effective solution providing advanced graphical interface features and enhanced performances. Secured migration managed by the manufacturer, thanks to an automatic migration tool and the use of a standard protocol. D-2 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Substation Automation Bay Controler BM9x00 by MiCOM C624 PE90877 Original brand: Areva or older ECOFIT™ proposal With ECOFIT™, a true extended life time 1994 2009 2014 2018 BM9x00 MiCOM C624 ECOFIT™ solution Commercialisation End of sales End of maintenance Main characteristics and performances BM9x00 MiCOM C624 Communication through legacy EFIP protocol with the SCADA level Standard communication through IEC61850 protocol to SCADA level Conection with Modbus, IEC870-5-103, IEC 870-5-101 Kbus (with K101CVT converter) and IEC61850 protocol for downstream relays Hardened to match substation cyber security requirements. Connection with Modbus, IEC103 or KBus communication with protection relay protocol No front side communication available for setting files management Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 D-3 Substation Automation PACIS OI V3.X UP TO V4.6 PE90879 Original brand: Areva or older by PACIS EcoSUI ECOFIT™ proposal With ECOFIT™, a true extended life time 2003 2005 2013 2014 PACiS OI PACIS EcoSUI ECOFIT™ solution Commercialisation End of Windows® 2000, XP commercialisation End of Microsoft support for Windows® XP Main characteristics and performances D-4 PACIS OI PACIS EcoSUI Windows® 2000 or XP Windows® 7 (32/64bits) Windows® server 2008 64bits One Ethernet network management Multi-LAN through IEC/IEC Gateways Multiple IEC61850 client access points Maximum handled dataflow 100 Measured Values archived /sec / server Direct IEC61850 configuration by import of SCD file Off-line modification & Time delayed deployment of database after recompilation Immediate deployment of database modification Redundancy switch over within 1 mn Hot redundancy seamless switchover Maximum handled dataflow 100 Measured Values archived /sec / server Handled dataflow up to 3000 MV archived /sec /server Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Substation Automation PSCN3020 HMI PE90878 Original brand: by EcoSUI HMI Areva or older ECOFIT™ proposal With ECOFIT™, a true extended life time 1994 2004 2009 2013 PSCN3020 HMI EcoSUI HMI ECOFIT™ solution Commercialisation End of Microsoft support for Windows® XP Obsolescence status Main characteristics and performances PSCN3020 HMI EcoSUI HMI Windows NT4 OS / 2 Windows® 7 ® One EFIP network management Configuration & database generation using proprietary & obsolete software Redundancy switch over within 1 mn Handled dataflow limited by EFIP protocol Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Open to Ethernet IEC61850 for all future extention and step by step replacement of bay controllers Direct IEC61850 configuration by import of SCD file for all new extensions Hot redundancy seamless switchover Handled dataflow up to 3000 MV archived /sec /server, once fully migrated to IEC61850 D-5 Substation Automation Seefox HMI by EcoSUI HMI PE90876 Original brand: Schneider Electric ECOFIT™ proposal With ECOFIT™, a true extended life time 1992 2005 2014 2020 Seefox HMI EcoSUI HMI ECOFIT™ solution End of commercialisation & Windows® XP support Commercialisation End of Windows® XP commercialisation End of maintenance Main characteristics and performances Seefox HMI EcoSUI HMI Windows® XP Full Schneider Electric HMI and tools design operating on Windows® 7 Based on third party HMI limited to Modbus TCP or Modbus + communication protocol IEC 61850 native in modeling configuration and communication Configuration tools no more supported or with limited upgrade facilities Ready for all standard substation extension using IEC61850 standard Compliant with substation cyber security requirements D-6 Medium & Low Voltage Distribution - Modernisation of switchboards - ECOFIT™ 2016 Medium & Low Voltage Distribution Modernisation of switchboards ECOFIT All over the world TM Tested, validated and certified by Schneider Electric Contact us! www.schneider-electric.com/electricaldistributionservices Discover the ECOFIT™ web selector: www.schneider-electric.com/en/tools/ecofit-selector The information contained in this document consists of general description of the available technical solutions and are for information purposes only. Schneider Electric does not make any warranty, representation, guarantee or promise, expressed or implied, about the completeness, accuracy and reliability of this information. The choice of the technical solutions will be defined in the contractual document and always subject to the proper installation and use in accordance with the related installation guide, the installation manual and the prevailing standard and/or installation regulations. The information is provided without liability and is subject to change without notice. Schneider Electric Industries SAS 35, rue Joseph Monier CS30323 F - 92505 Rueil-Malmaison cedex (France) RCS Nanterre 954 503 439 Share capital: €928,298,512 www.schneider-electric.com Internal documentation - 09/15 SERED111047EN ©2015 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies This document has been printed on recycled paper
Similar documents
m470n
W110 L217 H110 / W185 L217 H110 / W203 L217 H130 mattress size W90 L200 / W160 L200 / W180 L200
More informationInstallation Guide
7 Superseded Equipment - Installation Guide Index of Drawings DRAWING NUMBER DSM-7-01
More information