TRUflex™ PWR Series
Transcription
TRUflex™ PWR Series
TRUflex PWR_trifold_051512_RFPD.qxd:Layout 1 5/16/12 3:35 PM Page 1 TRUflex™ PWR Series High Power RF Cable Assemblies • Broad range of connector and cable combinations • kW power handling capabilities • Quick Connect/Disconnect interface technology • Test and adapter solutions available • Experience in high power design and safety innovations TRU Corporation offers an extensive line of flexible RF cable assembly and connector solutions for applications that require RF high power/voltage capability as well as reliable, high quality performance. Our long heritage in high power design has made us a premier supplier in high power markets including critical safety applications in the industrial equipment segment. Specifying the optimal assembly for your application is simplified by the broad selection of straight and right angle connector configurations and interface options, as well as the extensive range of cable choices. Our cables are specifically designed for their power capability and reliability. Our unique TRUtie™ cable termination method provides superior mechanical retention capabilities to eliminate the cable junction as a point of mechanical failure. Our innovative Quick Connect/Disconnect interfaces: TRU-SQS®, TRU-QRM™ and TRU-QDS®, provide highly efficient and repeatable high power solutions without the need for added hand tools to securely mate. In addition to the broad range of standard configurations in this brochure, TRU can also provide custom design solutions for your challenging applications. Our experienced Application Engineering team is available to personally answer all your technical questions. Visit our website or contact your local RichardsonRFPD sales office to find additional support and product information: trucorporation.com and richardsonrfpd.com 3/12/12 1:30 PM Page 2 TRUflex™ PWR Series TRUflex™ PWR Series TRUflex™ PWR Series Specifying High Power RF Cable Assemblies Coaxial Cable Reference Chart To simplify the process of specifying an RF high power cable assembly, follow the step-by-step instructions below. Please refer to the cable assembly below, which illustrates the various elements to specify. Cable Diameter (inches-nominal) Prior to selecting a cable and connectors please refer to the cable/connector selection matrix charts to determine available combinations. Cable Part Number Additional reference data has been provided to facilitate the proper selection of components for your application including frequency range and power handling. Ensure that the lower rating of either the connector interface or coaxial cable will support the overall power specification for the assembly. It is important to note that several factors such as temperature and altitude will potentially de-rate the overall power handling capability. Cable Dielectric (material/construction) Instructions Lengths ≤ 50 in (1,270 mm), tolerance = +/- 0.50 in (12.7 mm) Lengths > 50 in (1,270 mm), tolerance = +/- 1% of length C A Specify each connector interface and the configuration. (straight or right angle) B Identify any special marking requirements and their location. 0.390 0.450 0.490 0.545 0.565 TRU RG-393 TRU-450 TRU-500 TRU RG-217 TRU-560 7 strand 7 strand 7 strand solid 7 strand PTFE T-E/PTFE T-E/PTFE PE T-E/PTFE 2 3 2 2 2 Shields (type) TPC round SPC flat and round with interlayer SPC flat and round BC round SPC flat and round Cable Jacket (material/color) FEP brown FEP blue FEP blue PVC black PVC blue Cable Operating Temperature (°C) -55 to 200 -65 to 200 -55 to 200 -40 to 85 -55 to 105 Cable Minimum Bend Radius Static (inches) 1.50 1.50 1.50 2.75 1.70 Cable Minimum Bend Radius Dynamic (inches) N/A 2.50 2.45 N/A 2.80 6 GHz 10 GHz 6 GHz 3 GHz 6 GHz 50 50 50 50 50 Capacitance (pf/ft) 32.0 25.0 26.8 32.2 26.8 Shielding Effectiveness (dB minimum) -60 -90 -75 -60 -75 Velocity of Propagation (% nominal) 70 83 77 66 77 0.175 0.180 0.230 0.225 0.240 — — 12 kV 12 kV Center Conductor (stranded/solid) Standard Cable Assembly Length Tolerances Specify any relevant mechanical/electrical or environmental specifications. Standard marking is TRU part number and date code. Shields (number) Frequency (maximum) Impedance (Ohms- nominal) Weight (lbs /ft) SHRINK SLEEVE SHRINK SLEEVE Selecting a Connector Interface Power — Voltage 10 kV See graph below 8 kV 12 kV Mating Style Attributes Threaded Provides positive mechanical engagement and tight environmental seal when torqued properly. Conforms to standard industry interface specifications. Specify the length of the assembly. Reference coaxial cable chart for attribute data. Assemblies are generally measured from end to end for straight connectors, or from the centerline of right angle connectors, as shown. Mating Cycles (Minimum) Voltage Rating (Vrms) 7-16 7.5 > 500 2,700 LC 1.0 > 500 3,000 SC 11.0 > 500 1,000 HN 4.0 > 500 1,500 MEIA-1625 3.0 > 500 5,100 1-5/8 EIA 3.0 > 500 5,100 TRU-SQS® 0.5 > 2,500 4,000 TRU-QRM™ 1.0 > 2,500 3,500 TRU-QDS® 6.0 >2,500 1,000 RF Power Handling RF Power Handling 100,000 100,000 — TRU-QDS® — TRU-QRM™ — TRU-SQS® — TRU RG-217 — TRU RG-393 — TRU-450 — TRU-560 — TRU-500 100,000 Specify each connector interface and the configuration. (straight or right angle) Rapid connect/ disconnect by hand without the need for tooling. TRU-Redline™ indicator ensures full engagement. Provides safety measure in high power environments. Can be used with interlock safety switches. Quick Connect/ Disconnect CW Power (Watts) Specify coaxial cable required. A CW Power (Watts) E Maximum Frequency (GHz) Direct mechanical attachment using screw/bolt fasteners. Requires tools. Robust connection but labor intensive. Flange Mount RF Power Handling 1,000,000 D Interface 10,000 10,000 CW Power (Watts) TRUflex PWR_trifold_031212_TRU.qxd:Layout 1 — SC — HN — 7-16 — LC — MEIA-1625 1,000 1,000 10,000 1,000 1-5/8 EIA Connectors shown above are for reference only. 100 100 1 Sea Level 40°C Matched Load Specifications subject to change without notice. For additional specifications or other products, visit us online or contact the factory. trucorporation.com 1-800-262-9878 Specifications subject to change without notice. For additional specifications or other products, visit us online or contact the factory. 10 100 1,000 10 10,000 Sea Level 40°C Matched Load Frequency (MHz) trucorporation.com 1-800-262-9878 100 1,000 Frequency (MHz) Specifications subject to change without notice. For additional specifications or other products, visit us online or contact the factory. 10,000 100 1 10 Sea Level 40°C Matched Load 100 1,000 Frequency (MHz) trucorporation.com 1-800-262-9878 10,000 5/16/12 3:15 PM Page 2 TRUflex™ PWR Series TRUflex™ PWR Series TRUflex™ PWR Series Specifying High Power RF Cable Assemblies Coaxial Cable Reference Chart To simplify the process of specifying an RF high power cable assembly, follow the step-by-step instructions below. Please refer to the cable assembly below, which illustrates the various elements to specify. Cable Diameter (inches-nominal) Prior to selecting a cable and connectors please refer to the cable/connector selection matrix charts to determine available combinations. Cable Part Number Additional reference data has been provided to facilitate the proper selection of components for your application including frequency range and power handling. Ensure that the lower rating of either the connector interface or coaxial cable will support the overall power specification for the assembly. It is important to note that several factors such as temperature and altitude will potentially de-rate the overall power handling capability. Cable Dielectric (material/construction) Instructions Lengths ≤ 50 in (1,270 mm), tolerance = +/- 0.50 in (12.7 mm) Lengths > 50 in (1,270 mm), tolerance = +/- 1% of length C A Specify each connector interface and the configuration. (straight or right angle) B Identify any special marking requirements and their location. 0.390 0.450 0.490 0.545 0.565 TRU RG-393 TRU-450 TRU-500 TRU RG-217 TRU-560 7 strand 7 strand 7 strand solid 7 strand PTFE T-E/PTFE T-E/PTFE PE T-E/PTFE 2 3 2 2 2 Shields (type) TPC round SPC flat and round with interlayer SPC flat and round BC round SPC flat and round Cable Jacket (material/color) FEP brown FEP blue FEP blue PVC black PVC blue Cable Operating Temperature (°C) -55 to 200 -65 to 200 -55 to 200 -40 to 85 -55 to 105 Cable Minimum Bend Radius Static (inches) 1.50 1.50 1.50 2.75 1.70 Cable Minimum Bend Radius Dynamic (inches) N/A 2.50 2.45 N/A 2.80 6 GHz 10 GHz 6 GHz 3 GHz 6 GHz 50 50 50 50 50 Capacitance (pf/ ft) 32.0 25.0 26.8 32.2 26.8 Shielding Effectiveness (dB minimum) -60 -90 -75 -60 -75 Velocity of Propagation (% nominal) 70 83 77 66 77 0.175 0.180 0.230 0.225 0.240 — — 12 kV 12 kV Center Conductor (stranded/ solid) Standard Cable Assembly Length Tolerances Specify any relevant mechanical/electrical or environmental specifications. Standard marking is TRU part number and date code. Shields (number) Frequency (maximum) Impedance (Ohms- nominal) Weight (lbs/ft) SHRINK SLEEVE SHRINK SLEEVE Selecting a Connector Interface Power — Voltage 10 kV See graph below 8 kV 12 kV RF Power Handling Reference coaxial cable chart for attribute data. Assemblies are generally measured from end to end for straight connectors, or from the centerline of right angle connectors, as shown. — TRU RG-217 — TRU RG-393 — TRU-450 — TRU-560 — TRU-500 Mating Cycles (Minimum) Voltage Rating (Vrms) 7-16 7.5 > 500 2,700 LC 1.0 > 500 3,000 SC 11.0 > 500 1,000 HN 4.0 > 500 1,500 MEIA-1625 3.0 > 500 5,100 1-5/8 EIA 3.0 > 500 5,100 TRU-SQS® 0.5 > 2,500 4,000 TRU-QRM™ 1.0 > 2,500 3,500 TRU-QDS® 6.0 > 2,500 1,000 Direct mechanical attachment using screw/bolt fasteners. Requires tools. Robust connection but labor intensive. Rapid connect/ disconnect by hand without the need for tooling. TRU-Redline™ indicator ensures full engagement. Provides safety measure in high power environments. Can be used with interlock safety switches. RF Power Handling 100,000 — TRU-QDS® — TRU-QRM™ — TRU-SQS® 1 10,000 — SC — HN — 7-16 — LC — MEIA-1625 1,000 1,000 10,000 1,000 1-5/8 EIA Connectors shown above are for reference only. 100 1 Sea Level 40°C Matched Load Specifications subject to change without notice. For additional specifications or other products, visit us online or contact the factory. Maximum Frequency (GHz) RF Power Handling — TRU 500/560 — TRU 450 — TRU RG-217 — TRU RG-393 10 10,000 Interface 100,000 CW Power (Watts) Specify the length of the assembly. Provides positive mechanical engagement and tight environmental seal when torqued properly. Conforms to standard industry interface specifications. Quick Connect/ Disconnect 100 100,000 Specify each connector interface and the configuration. (straight or right angle) Threaded Flange Mount dB /100 ft Specify coaxial cable required. A CW Power (Watts) E Attributes Attenuation 1,000,000 D Mating Style CW Power (Watts) TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 trucorporation.com 1-800-262-9878 10 100 1,000 Frequency (MHz) Specifications subject to change without notice. For additional specifications or other products, visit us online or contact the factory. 10,000 100 0.1 1 10 Ambient Temp 20°C Matched Load 100 1,000 10,000 Sea Level 40°C Matched Load Frequency (MHz) trucorporation.com 1 1-800-262-9878 10 100 1,000 Frequency (MHz) Specifications subject to change without notice. For additional specifications or other products, visit us online or contact the factory. 10,000 100 1 10 Sea Level 40°C Matched Load 100 1,000 Frequency (MHz) trucorporation.com 1-800-262-9878 10,000 5/16/12 3:15 PM Page 2 TRUflex™ PWR Series TRUflex™ PWR Series TRUflex™ PWR Series Specifying High Power RF Cable Assemblies Coaxial Cable Reference Chart To simplify the process of specifying an RF high power cable assembly, follow the step-by-step instructions below. Please refer to the cable assembly below, which illustrates the various elements to specify. Cable Diameter (inches-nominal) Prior to selecting a cable and connectors please refer to the cable/connector selection matrix charts to determine available combinations. Cable Part Number Additional reference data has been provided to facilitate the proper selection of components for your application including frequency range and power handling. Ensure that the lower rating of either the connector interface or coaxial cable will support the overall power specification for the assembly. It is important to note that several factors such as temperature and altitude will potentially de-rate the overall power handling capability. Cable Dielectric (material/construction) Instructions Lengths ≤ 50 in (1,270 mm), tolerance = +/- 0.50 in (12.7 mm) Lengths > 50 in (1,270 mm), tolerance = +/- 1% of length C A Specify each connector interface and the configuration. (straight or right angle) B Identify any special marking requirements and their location. 0.390 0.450 0.490 0.545 0.565 TRU RG-393 TRU-450 TRU-500 TRU RG-217 TRU-560 7 strand 7 strand 7 strand solid 7 strand PTFE T-E/PTFE T-E/PTFE PE T-E/PTFE 2 3 2 2 2 Shields (type) TPC round SPC flat and round with interlayer SPC flat and round BC round SPC flat and round Cable Jacket (material/color) FEP brown FEP blue FEP blue PVC black PVC blue Cable Operating Temperature (°C) -55 to 200 -65 to 200 -55 to 200 -40 to 85 -55 to 105 Cable Minimum Bend Radius Static (inches) 1.50 1.50 1.50 2.75 1.70 Cable Minimum Bend Radius Dynamic (inches) N/A 2.50 2.45 N/A 2.80 6 GHz 10 GHz 6 GHz 3 GHz 6 GHz 50 50 50 50 50 Capacitance (pf/ ft) 32.0 25.0 26.8 32.2 26.8 Shielding Effectiveness (dB minimum) -60 -90 -75 -60 -75 Velocity of Propagation (% nominal) 70 83 77 66 77 0.175 0.180 0.230 0.225 0.240 — — 12 kV 12 kV Center Conductor (stranded/ solid) Standard Cable Assembly Length Tolerances Specify any relevant mechanical/electrical or environmental specifications. Standard marking is TRU part number and date code. Shields (number) Frequency (maximum) Impedance (Ohms- nominal) Weight (lbs/ft) SHRINK SLEEVE SHRINK SLEEVE Selecting a Connector Interface Power — Voltage 10 kV See graph below 8 kV 12 kV RF Power Handling Reference coaxial cable chart for attribute data. Assemblies are generally measured from end to end for straight connectors, or from the centerline of right angle connectors, as shown. — TRU RG-217 — TRU RG-393 — TRU-450 — TRU-560 — TRU-500 Mating Cycles (Minimum) Voltage Rating (Vrms) 7-16 7.5 > 500 2,700 LC 1.0 > 500 3,000 SC 11.0 > 500 1,000 HN 4.0 > 500 1,500 MEIA-1625 3.0 > 500 5,100 1-5/8 EIA 3.0 > 500 5,100 TRU-SQS® 0.5 > 2,500 4,000 TRU-QRM™ 1.0 > 2,500 3,500 TRU-QDS® 6.0 > 2,500 1,000 Direct mechanical attachment using screw/bolt fasteners. Requires tools. Robust connection but labor intensive. Rapid connect/ disconnect by hand without the need for tooling. TRU-Redline™ indicator ensures full engagement. Provides safety measure in high power environments. Can be used with interlock safety switches. RF Power Handling 100,000 — TRU-QDS® — TRU-QRM™ — TRU-SQS® 1 10,000 — SC — HN — 7-16 — LC — MEIA-1625 1,000 1,000 10,000 1,000 1-5/8 EIA Connectors shown above are for reference only. 100 1 Sea Level 40°C Matched Load Specifications subject to change without notice. For additional specifications or other products, visit us online or contact the factory. Maximum Frequency (GHz) RF Power Handling — TRU 500/560 — TRU 450 — TRU RG-217 — TRU RG-393 10 10,000 Interface 100,000 CW Power (Watts) Specify the length of the assembly. Provides positive mechanical engagement and tight environmental seal when torqued properly. Conforms to standard industry interface specifications. Quick Connect/ Disconnect 100 100,000 Specify each connector interface and the configuration. (straight or right angle) Threaded Flange Mount dB /100 ft Specify coaxial cable required. A CW Power (Watts) E Attributes Attenuation 1,000,000 D Mating Style CW Power (Watts) TRUflex PWR_trifold_051512_TRU.qxd:Layout 1 trucorporation.com 1-800-262-9878 10 100 1,000 Frequency (MHz) Specifications subject to change without notice. For additional specifications or other products, visit us online or contact the factory. 10,000 100 0.1 1 10 Ambient Temp 20°C Matched Load 100 1,000 10,000 Sea Level 40°C Matched Load Frequency (MHz) trucorporation.com 1 1-800-262-9878 10 100 1,000 Frequency (MHz) Specifications subject to change without notice. For additional specifications or other products, visit us online or contact the factory. 10,000 100 1 10 Sea Level 40°C Matched Load 100 1,000 Frequency (MHz) trucorporation.com 1-800-262-9878 10,000 TRUflex PWR_trifold_031212_TRU.qxd:Layout 1 3/12/12 5:34 PM Page 1 TRUflex™ PWR Series TRUflex™ PWR Series TRUflex™ PWR Series Quick Connect/Disconnect Connector Configurations Threaded and Flange Mount Connector Configurations TRU Corporation Quick-Connect/Disconnect RF interface provides reliable mating with fast connect/disconnect capability. These interfaces feature a positive locking mechanism employing a spring-loaded sleeve on the male plug that is drawn back to let self-contained bearings “click” into grooves on the mating female receptacle, and slide forward. A fully mated and safe condition is visually represented with full coverage of our TRU-Redline™ indicator. These designs provide exceptionally fast and reliable hand mating that will not vibrate loose. TRU offers a broad range of standard high power cable connector designs and configurations to provide the maximum flexibility for your design. In addition to those shown below, TRU can provide custom designs and features per your specification. TRU also offers a broad range of panel mount receptacles with high power/voltage capability and application specific launch geometries. 2.90" 2.70" 3.40" 1.70" 3.06" 2.75" TRU-QDS® Straight Plug 2.45" 2.40" 2.80" 2.87" 2.00" TRU-QRM ™ Right Angle Plug 1.26" 2.20" 1.40" TRU-SQS® Right Angle Plug 0.93" SC Straight Plug LC Straight Plug 7-16 Straight Plug TRU-QRM ™ Straight Plug TRU-SQS® Straight Plug 3.10" 1.63" 1.25" 1.13" 1.50" 0.5" TRU-QDS® Right Angle Plug 1.90" 1.50" 1.62" LC Right Angle Plug 7-16 Right Angle Plug 1.17" SC Right Angle Plug 0.50" Dimensions shown are reference only. 3.75" 4.35" 1.64" 2.38" 3.50" MEIA-1625 Straight Plug Dimensions shown are reference only. High Power RF Cable Assemblies • Broad range of connector and cable combinations 1-5/8 EIA Straight Plug • kW power handling capabilities • Quick Connect/Disconnect interface technology • Test and adapter solutions available • Experience in high power design and safety innovations TRU-SQS® right angle, cable plug and panel mount receptacle shown in unmated condition. TRU-SQS® spring-loaded sleeve is retracted and interfaces engaged. Note TRU-Redline™ indicator is still visible until sleeve is released and a fully mated condition is present. TRU-SQS® interfaces shown in a fully mated condition. The right angle assembly can be mated at any position along a 360° arc offering optimal flexibility in the assembly orientation. TRU Corporation, Peabody, MA 01960 USA 1 800 262-9878 (1 800 COAX-TRU) 978 532-0775 022012-003 Specifications subject to change without notice. For additional specifications or other products, visit us online or contact the factory. To request literature: [email protected] trucorporation.com 1-800-262-9878 trucorporation.com TRU Corporation offers an extensive line of flexible RF cable assembly and connector solutions for applications that require RF high power/voltage capability as well as reliable, high quality performance. Our long heritage in high power design has made us a premier supplier in high power markets including critical safety applications in the industrial equipment segment. Specifying the optimal assembly for your application is simplified by the broad selection of straight and right angle connector configurations and interface options, as well as the extensive range of cable choices. Our cables are specifically designed for their power capability and reliability. Our unique TRUtie™ cable termination method provides superior mechanical retention capabilities to eliminate the cable junction as a point of mechanical failure. Our innovative Quick Connect/Disconnect interfaces: TRU-SQS®, TRU-QRM™ and TRU-QDS®, provide highly efficient and repeatable high power solutions without the need for added hand tools to securely mate. In addition to the broad range of standard configurations in this brochure, TRU can also provide custom design solutions for your challenging applications. Our experienced Application Engineering team is available to personally answer all your technical questions. Visit our website to find additional support and product information: trucorporation.com TRUflex PWR_trifold_051512_RFPD.qxd:Layout 1 5/16/12 3:39 PM Page 1 TRUflex™ PWR Series Threaded and Flange Mount Connector Configurations TRU offers a broad range of standard high power cable connector designs and configurations to provide the maximum flexibility for your design. In addition to those shown below, TRU can provide custom designs and features per your specification. TRU also offers a broad range of panel mount receptacles with high power/voltage capability and application specific launch geometries. 3.06" 2.75" 0.5" 3.10" SC Straight Plug LC Straight Plug 7-16 Straight Plug 0.93" 1.63" 1.25" 2.45" 2.87" 1.40" 1.62" LC Right Angle Plug 7-16 Right Angle Plug 1.26" 1.17" SC Right Angle Plug 0.50" 3.75" 4.35" 1.64" 2.38" 3.50" MEIA-1625 Straight Plug 1-5/8 EIA Straight Plug Dimensions shown are reference only. TRU Corporation, Peabody, MA 01960 USA 1 800 262-9878 (1 800 COAX-TRU) 978 532-0775 052012-005 To request literature: [email protected] trucorporation.com Corporate Headquarters Richardson RFPD 40W267 Keslinger Road P.O. Box 307 LaFox, IL 60147-0307 USA Toll Free: 800-737-6937 Phone: 630-208-2700 Fax: 630-208-2662 Internet: www.richardsonrfpd.com Email: [email protected]