Herculink Elite

Transcription

Herculink Elite
RENAL
ILIAC
SFA
BTK
Products by indication
CAROTID
Navigate with a new level of control
Embolic Protection System
Embolic Protection
Navigation
Ordering Information
Three new .014" BareWires designed specifically for carotid
anatomies to ensure navigational success.
Emboshield NAV6 Embolic Protection System*
Distal Access: A softer BareWire with extra flexibility and torqueability for successful
access through tortuous anatomy.
Carotid
Emboshield NAV
6
0.014"
Ref. No. Vessel Diameter Wire Length [cm] Introducer/Guiding Catether Compatibility [F]
22442-19 (small) 2.5-4.8 190 5/6
22443-19 (large) 4.0-7.0 190 5/6
*Emboshield NAV6 Embolic Protection System consists of 2 primary packs:
Workhorse: Provides optimal flexibility and support for superb access through most
anatomies.
Primary Pack
Filtration System
Content
(1) RX Delivery Catheter, (1) Filtration Element, (1) BareWire Filter Delivery Wire (Workhorse,
190 cm), (1) Loading Funnel, (1) Introducer, (1) Torque Device, (1) Syringe with Flushing Tip
RX Retrieval Catheter
(1) RX Retrieval Catheter, (1) Torque Device, (1) Syringe Flushing Tip
BareWire Filter Delivery Wires (.014")**
Support: Designed to provide additional support for delivery of filter in challenging arches.
Wire Type Ref. No. Wire Length [cm]
Distal Access 22444-19 190
Workhorse 22445-19 22445-31 190
315
Support 22446-19 190
**BareWires sold in packs of five.
Access
.019" Step
for filter retrieval
Three filter delivery options provide a customized approach to access
diverse vascular anatomies.
BareWire: Wire access
followed by easy filter delivery
through tight lesions and
challenging anatomies.
Fixed: Preloaded wire filter
delivery system for one-step
advancement through lesion.
Excellent Filter Design
engineered for enhanced
capture and flow
Telescope: Alternate
advancement of BareWire
and delivery system for
unparalleled access and
support.
• Navigation
Visibility
• Access
Radiopaque circumferential frame conveys vessel
apposition and deployment status.
• Visibility
Short Filter Length
120 µm Pore Size with maximum
pores for optimal capture efficiency
and blood flow
19.0 and 22.5 mm.
Fully deployed
2
Fully captured
BareWire Advantage:
Filter is independent of wire
Hydrophilic Coating designed to
reduce protein and platelet adhesion
3
Embolic Protection System
Embolic Protection
Dual strut filter basket
Ordering Information
1Stability
2Optimal protection
3Visibility
4Flexibility
•Multiple points of contact between filter
and vessel for optimal wall apposition
•Filter wire torqued independently from filter
•Four platinum radiopaque markers on all
filter struts
Carotid
RX Accunet
Natural stability
0.014"
190 cm
Wire Length Ref. No. 300 cm
Wire Length
Ref. No. Filter
Size
[mm] Vessel Diameter
[mm] Introducer/
Guiding Catether Compatibility
[F] 1011651-45 1011652-45 4.50 3.25-4.00 6/8
1011651-55 1011652-55 5.50 4.00-5.00 6/8
1011651-65 1011652-65 6.50 5.00-6.00 6/8
1011651-75 1011652-75 7.50 6.00-7.00 6/8
•Homogeneous laser-cut holes
•Large capture volume while allowing
blood flow
•Highly flexible nitinol filter basket to
conform to vessel tortuosity
2 different recovery catheter choices for challenging anatomies
RX Accunet recovery catheter
“Shapeable tip design”
•Shapeable distal tip deflects catheter
from stent struts
RX Accunet 2 recovery catheter
“Flexible tip design”
•Soft, low-profile flexible tip to allow for
smooth advancement
•Proximal markers for increased ease of
use and reduced fluoro time
Shapeable recovery
catheter tip
RX delivery system
Ease of use
•Balance heavyweight guide wire platform with floppy, pre-shapeable radiopaque tip
•RX unsheathing for stability and simplicity
•Peel-away delivery sheath allows for controlled deployment
Flexible recovery
catheter tip
• Dual strut filter basket
• 2 different recovery catheter choices
• RX delivery system
4
5
Rapid Exchange Carotid Stent System
Carotid Stenting
Xact Carotid Stent
Ordering Information
Nitinol construction
•Straight and tapered
configurations
•Accurate sizing
•Minimal foreshortening
•Exceptional crush resistance
Unique variable cell size
•Increased radial force at lesion
•Increased stent coverage at
lesion designed to minimise
plaque extrusion
Carotid
Xact
Accurate placement with strength
where it counts
0.014"
Straight Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] ICA Reference
Vessel Diameter
[mm] CCA Reference
Vessel Diameter
[mm]
XRX02007S
XRX02008S
XRX02009S
XRX02010S
7 8 9 10 20
20
20
20
6
6
6
6
>5.5-6.4
>6.4-7.3
>7.3-8.2
>8.2-9.1
N/A
N/A
N/A
N/A
XRX03007S
XRX03008S
XRX03009S
XRX03010S
7 8 9 10 30
30
30
30
6
6
6
6
>5.5-6.4
>6.4-7.3
>7.3-8.2
>8.2-9.1
N/A
N/A
N/A
N/A
Tapered Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] ICA Reference
Vessel Diameter
[mm] CCA Reference
Vessel Diameter
[mm]
XRX03008T
XRX03009T
XRX03010T
8-6 9-7 10-8 30 30 30 6 6 6 4.8-5.5
>5.5-6.4
>6.4-7.3
6.4-7.3
7.3-8.2
8.2-9.1
XRX04008T
XRX04009T
XRX04010T
8-6 9-7 10-8 40 40 40 6 6 6 4.8-5.5
>5.5-6.4
>6.4-7.3
6.4-7.3
7.3-8.2
8.2-9.1
•Reduced radial force at
healthy vessel segments
•Cell design minimises
risk of snagging
Xact Tapered
Xact Straight
Freestyle Technology
•Stability of system allows accurate placement every time
•Low crossing profile (5.7F)
•Excellent pushability and trackability
•Outstanding radiopacity
• Freestyle Technology
Single handed operation
6
• Unique variable cell size
7
Carotid Stent System
Carotid Stenting
The advantages of an innovative design
Ordering Information
•Highly flexible stents conform to natural vessel anatomies
• Truly tapered stents avoid excessive radial force in smaller diameter, internal carotid arteries
• Excellent wall apposition ensures sustained long-term plaque coverage
• Excellent surface finishing maximizes stent longevity
Tapered
Straight
Straight Ref. No. Stent Diameter [mm] 0.014"
Stent Length [mm] Introducer Compatibility [F] ICA Reference
Vessel Diameter
[mm] CCA Reference
Vessel Diameter
[mm]
1010126-205
1010127-206
1010128-207
1010129-208
1010130-209
1010131-2010
20
20
20
20
20
20
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.4
5.7-7.3
6.4-8.2
7.1-9.1
N/A
N/A
N/A
N/A
N/A
N/A
1010126-305
1010127-306
1010128-307
1010129-308
1010130-309
1010131-3010
30
30
30
30
30
30
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.4
5.7-7.3
6.4-8.2
7.1-9.1
N/A
N/A
N/A
N/A
N/A
N/A
1010126-405
1010127-406
1010128-407
1010129-408
1010130-409
1010131-4010
40
40
40
40
40
40
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.4
5.7-7.3
6.4-8.2
7.1-9.1
N/A
N/A
N/A
N/A
N/A
N/A
Tapered Ref. No. Stent Length [mm] Introducer Compatibility [F] ICA Reference
Vessel Diameter
[mm] CCA Reference
Vessel Diameter
[mm]
1010132-306-8
1010133-307-10
30
30
6
6
4.3-5.4
5.0-6.4
5.7-7.3
7.1-9.1
1010132-406-8
1010133-407-10
40
40
6
6
4.3-5.4
5.0-6.4
5.7-7.3
7.1-9.1
Stent Diameter [mm] Carotid
RX Acculink
Inspired by nature
• Highly flexible stent
• Low profile
• RX Technology
8
9
HI-TORQUE .014" Guide Wire
Guide Wires
Excellent .014" support with superb steerability and
an atraumatic tip
Ordering Information
0.014"
Ref. No.
Floppy -Tip Length
[cm]
Wire Length
[cm]
•High support .014" stainless steel shaft
1005201 1005204 5
10
130*
130*
•5 cm and 10 cm intermediate segments provide excellent torque response
1005202 1005205 5
10
190
190
•Soft, atraumatic shapeable tip
1005203 1005206 5
10
300
300
Engage clinical challenges with support and control
Renal
SPARTACORE 14
Extra support for
lower limb procedures
•“Core-to-tip” design for precise steering and tip control
•MICROGLIDE coating provides low friction and superb trackability
Torque devices sold separately in packs of ten (Ref. No. 22215).
*Compatible with DOC guide wire extensions (Ref. No. 22260).
•PTFE coating up to distal 7 cm
•4 cm radiopaque tip coil
•Platinum marker to locate the wire accurately. Measured from the distal tip: 55 cm for the
130 cm length, 90 cm for the 190 cm length, 100 cm for the 300 cm length
•Available in 130, 190, 300 cm length
Transition length
5 cm
10 cm
10
11
PTA Balloon Catheter
Balloon Dilatation Catheters
Low-profile access
Ordering Information
•.014" guide wire size for easy lesion cross
•6F guiding catheter compatibility up to 7.0 mm diameter
•Easy contrast injections in a 6F guiding catheter
Balloon Ø [mm]
Minimum Guide Size [F]
Minimum Sheath Size [F]
(RX) Rapid exchange
•Compatible with shorter 130 cm guide wires
0.014"
80 cm USL
135 cm USL
Ref. No.
Ref. No.
Balloon Balloon
Introducer
Diameter
Length
Compatibility
[mm] [mm][F]
Nominal
Rated Burst
Pressure (NP)
Pressure (RBP)
[atm][atm]
1008190-151008189-15
1008192-151008191-15
1008194-151008193-15
1008196-151008195-15
1008198-151008197-15
1008200-151008199-15
1008202-151008201-15
4.0
4.5
5.0
5.5
6.0
6.5
7.0
15
15
15
15
15
15
15
4
4
5
5
5
5
5
8
8
8
8
8
8
8
14
14
14
14
14
14
14
1008190-201008189-20
1008192-201008191-20
1008194-201008193-20
1008196-201008195-20
1008198-201008197-20
1008200-201008199-20
1008202-201008201-20
4.0
4.5
5.0
5.5
6.0
6.5
7.0
20
20
20
20
20
20
20
4
4
5
5
5
5
5
8
8
8
8
8
8
8
14
14
14
14
14
14
14
1008190-301008189-30
1008192-301008191-30
1008194-301008193-30
1008196-301008195-30
1008198-301008197-30
1008200-301008199-30
1008202-301008201-30
4.0
4.5
5.0
5.5
6.0
6.5
7.0
30
30
30
30
30
30
30
4
4
5
5
5
5
5
8
8
8
8
8
8
8
14
14
14
14
14
14
14
1008190-401008189-40
1008192-401008191-40
1008194-401008193-40
1008196-401008195-40
1008198-401008197-40
1008200-401008199-40
1008202-401008201-40
4.0
4.5
5.0
5.5
6.0
6.5
7.0
40
40
40
40
40
40
40
4
4
5
5
5
5
5
8
8
8
8
8
8
8
14
14
14
14
14
14
14
Renal
Viatrac 14 Plus
Delivering performance through
low-profile access
•Single operator control
•Fast balloon exchanges
High-pressure strength
•Durable XCELON nylon material offers resilient high pressure capabilities (14 atm RBP)
Radiopaque balloon markers
•Advanced balloon processing designed for enhanced rewrap and easy withdrawal
Deliverable performance
.014" maximum guide wire lumen
•Flexible distal catheter offers excellent trackability
•Tapered support mandrel inside catheter designed to provide shaft pushability
and kink resistance
• True .014" system
•MICROGLIDE coated shaft and balloon for reduced friction
• Rapid exchange
• High pressure strength
XCELON balloon material
12
Soft, tapered tip
13
0.014"
Peripheral Stent System
Balloon Expandable Stent Systems
RX Herculink Elite
Ordering Information
Building on the proven1 deliverability of RX Herculink, using the advanced metallurgy of cobalt
chromium, RX Herculink Elite sets new standards in renal stenting: excellent radiopacity, low
profile, high radial strength and superb stent flexibility.
80 cm USL Ref. No. •Grip technology helps ensure excellent stent retention, smooth surface transitions and protection of stent edges
•14 atm RBP delivers high-pressure capabilities on a low profile system
135 cm USL Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Comp. [F] Nominal
Pressure (NP)
[atm]
Renal
RX Herculink Elite
The deliverability of RX Herculink
- the performance of CoCr
Rated Burst
Pressure (RBP)
[atm]
1011521-12
1011522-12
4.0 125
1011524-12
1011525-12
4.5 125
1011527-12
1011528-12
5.0 125
1011530-12
1011531-12
5.5 125
1011533-12
1011534-12
6.0 125
1011536-12
1011537-12
6.5 125
1114
1114
1114
1114
1114
1114
1011521-15
1011522-15
4.0 155
1011524-15
1011525-15
4.5 155
1011527-15
1011528-15
5.0 155
1011530-15
1011531-15
5.5 155
1011533-15
1011534-15
6.0 155
1011536-15
1011537-15
6.5 155
1011539-15
1011540-15
7.0 155
1114
1114
1114
1114
1114
1114
1114
1011521-18
1011522-18
4.0 185
1011524-18
1011525-18
4.5 185
1011527-18
1011528-18
5.0 185
1011530-18
1011531-18
5.5 185
1011533-18
1011534-18
6.0 185
1011536-18
1011537-18
6.5 185
1011539-18
1011540-18
7.0 185
1114
1114
1114
1114
1114
1114
1114
XCELON balloon material and Grip technology ensure excellent
sizing flexibility and a safe procedure.
Stainless steel
stent
RX Herculink
Elite
6F
6F GUIDE
5F
5F SHEATH
• Excellent radiopacity
Excellent radiopacity
Low profile
Superb flexibility
• Superb flexibility1
• Low profile
1. Data on file at Abbott Vascular.
14
1. Comparison to RX HERCULINK PLUS Biliary Stent System
15
HI-TORQUE .035" Guide Wire
Guide Wires
Steerability and support in a .035" peripheral
guide wire
Ordering Information
Supportive .035" wire with soft atraumatic tip
•Able to facilitate device placement and exchange throughout an entire procedure
• Provide the foundation for nearly all your diagnostic and therapeutic needs in the
peripheral anatomy
0.035"
Ref. No.
Tip Shape
Wire Length
[cm]
1002703 Straight
145
1002703-01 Straight
190
1002703-02 Straight
300
Iliac
SUPRA CORE 35
Extra support for
lower limb procedures
Torque devices sold separately and in packs of ten (Ref. No. 1003279).
• Designed to ensure successful clinical performance and successful patient outcomes
• Amplatz support with Wholey tip
• One-to-one torque response provides exceptional steerability
• Radiopaque markers to control wire stability during the procedure
• Available in 145, 190 and 300 cm length
One-to-one torque response
provides exceptional
steerability
Proximal .025" outer diameter ensures
.035" compatible device exchanges
16
MICROGLIDE coating reduces friction,
improving wire movement and catheter
trackability
Exclusively designed 17 cm, tapered .025" core allows
support with flexibility for varied device delivery and
applications Widow
Radiopaque tip allows excellent
guide wire placement
Shapeable, atraumatic tip
17
Armada 35
A Step Ahead
PTA Catheter
Balloon Dilatation Catheters
Designed to streamline your procedure from start to finish
Ordering Information
Armada 35 is designed to optimize PTA performance at each stage of your procedure.
The combination of finesse and power reduces the need for specialty balloons and keeps
you a step ahead in your cases.
80 cm
Catheter Length
Ref. No.
A comprehensive portfolio* with each size range engineered for specific clinical situations.
•Small lesion entry profile
•Strong pushability
•High RBP (up to 28 bar)
Workhorse and
Pre-Dilatation
•Diameters up to 14 mm
•Low sheath size compatibility (6F sheath compatible up to 12 mm)
•Fast deflation times
Large
Diameter
Frontline performance even in high pressure situations
Unmatched pushability with the lowest tip and balloon crossing profiles** to enter and cross lesions without
compromising RBP.
Push Transmission (%)
Lesion Crossing Profile (mm)
53
42
41
1.64
E
D
A = EverCross
B = Admiral Xtreme
1.85
1.86
39
30
ARMADA
35
1.73 1.77
C
B
28
F
25
A
C = Dorado
D = Powerflex P3
1.88
24
22
18
ARMADA
35
1.87
A
17
B
15
F
E = Rival
F = Ultra-thin Diamond
C
15
14
D
E
= RBP
(bar)
135 cm
Catheter Length
Ref. No.
Balloon
Diameter
[mm]
Balloon
Min Sheath
Length
Size [F]
[mm]
Nominal
Pressure
[atm]
RBP
[atm]
B1030-020B2030-020 3.0 20 5
B1030-040B2030-040 3.0 40 5
8 28
8 28
B1040-020B2040-020 4.0
B1040-040B2040-040 4.0
B1040-060B2040-060 4.0
B1040-080B2040-080 4.0
B1040-100B2040-100 4.0
B1040-120B2040-120 4.0
20 5
40 5
60 5
80 5
100 5
120 5
8
8
8
8
8
8
25
25
25
20
20
20
B1050-020B2050-020 5.0
B1050-040B2050-040 5.0
B1050-060B2050-060 5.0
B1050-080B2050-080 5.0
B1050-100B2050-100 5.0
B1050-120B2050-120 5.0
20 5
40 5
60 5
80 5
100 5
120 5
8
8
8
8
8
8
22
22
20
18
18
18
B1060-020B2060-020 6.0
B1060-040B2060-040 6.0
B1060-060B2060-060 6.0
B1060-080B2060-080 6.0
B1060-100B2060-100 6.0
B1060-120B2060-120 6.0
20 5
40 5
60 5
80 5
100 5
120 5
6
6
6
6
6
6
20
20
18
16
16
16
B1070-020B2070-020 7.0
B1070-040B2070-040 7.0
B1070-060B2070-060 7.0
B1070-080B2070-080 7.0
B1070-100B2070-100 7.0
B1070-120B2070-120 7.0
20 5
40 5
60 5
80 5
100 6
120 6
6
6
6
6
6
6
15
15
15
14
14
14
B1080-020B2080-020 8.0
B1080-040B2080-040 8.0
B1080-060B2080-060 8.0
B1080-080B2080-080 8.0
20
40
60
80
6
6
6
6
6
6
6
6
15
15
14
13
B1090-020B2090-020 9.0
B1090-040B2090-040 9.0
B1090-060B2090-060 9.0
B1090-080B2090-080 9.0
20
40
60
80
6
6
6
6
6
6
6
6
14
13
12
12
B1100-020B2100-020 10.0 20
B1100-040B2100-040 10.0 40
B1100-060B2100-060 10.0 60
B1100-080B2100-080 10.0 80
6
6
6
6
6
6
6
6
13
12
11
10
B1120-020B2120-020 12.0 20
B1120-040B2120-040 12.0 40
B1120-060B2120-060 12.0 60
B1120-080B2120-080 12.0 80
6
6
6
6
4
4
4
4
10
10
9
9
B1140-020B2140-020 14.0 20
B1140-040B2140-040 14.0 40
B1140-060B2140-060 14.0 60
B1140-080B2140-080 14.0 80
7
7
7
7
4
4
4
4
8
8
7
7
Iliac
Engineered to treat the broadest range of lesions
0.035"
6F sheath
compatible up to 12 mm
* Source: AV Market Intelligence among top competitive devices.
**Based on tip and balloon crossing profile measurements and pushability performance bench tests among competitors tested. (Powerflex P3, Ultrathin Diamond, Admiral Xtreme, Dorado, Rival, EverCross)
18
19
Armada 35 LL
A Step Ahead
PTA Catheter
Balloon Dilatation Catheters
Designed to streamline your procedure from start to finish
Ordering Information
Armada 35 LL is designed to optimize PTA performance at each stage of your procedure.
The combination of finesse and power reduces the need for specialty balloons and keeps
you a step ahead in your cases.
80 cm
Catheter Length
Ref. No.
0.035"
Balloon
Diameter
[mm]
Balloon
Min Sheath
Length
Size [F]
[mm]
Nominal
Pressure
[atm]
RBP
[atm]
B1040-150B2040-150 4.0 150 5
B1040-200B2040-200 4.0 200 5
B1040-250B2040-250 4.0 250 5
8 20
8 18
8 18
Engineered to treat the broadest range of lesions
B1050-150B2050-150 5.0 150 5
B1050-200B2050-200 5.0 200 5
B1050-250B2050-250 5.0 250 5
8 18
8 18
8 16
A comprehensive portfolio* with each size range engineered for specific clinical situations.
B1060-150B2060-150 6.0 150 5
B1060-200B2060-200 6.0 200 6
B1060-250B2060-250 6.0 250 6
6 16
6 14
6 12
B1070-150B2070-150 7.0 150 6
B1070-200B2070-200 7.0 200 6
6 14
6 13
Workhorse and
Pre-Dilatation
•Small lesion entry profile
•Strong pushability
Long
Length (LL)
•Lengths up to 250 mm
• Low lesion crossing profiles
• Strong pushability
• Controlled 3D compliance
6F sheath
Frontline performance even in high pressure situations
Unmatched pushability with the lowest tip and balloon crossing profiles** to enter and cross lesions without
compromising RBP.
Push Transmission (%)
41
1.64
ARMADA
35
E
D
A = EverCross
B = Admiral Xtreme
1.73 1.77
1.85
1.86
39
30
C
B
compatible up to 7 x 200 mm
Lesion Crossing Profile (mm)
53
42
Iliac
135 cm
Catheter Length
Ref. No.
28
F
25
A
C = Dorado
D = Powerflex P3
1.88
15
14
D
E
24
22
18
ARMADA
35
1.87
A
17
B
15
F
E = Rival
F = Ultra-thin Diamond
C
= RBP
(bar)
* Source: AV Market Intelligence among top competitive devices.
**Based on tip and balloon crossing profile measurements and pushability performance bench tests among competitors tested. (Powerflex P3, Ultrathin Diamond, Admiral Xtreme, Dorado, Rival, EverCross)
20
21
FOXcross
Designed to get you there
PTA Catheter
Balloon Dilatation Catheters
Totally coated balloon system – reduced friction
Ordering Information
50 cm Usable
Shaft Length
Ref. No.
•Improved trackability
•Improved crossability, especially in calcified long lesions
•Reduced pull-back force
Effect of jet coating on balloon system
Average/Min/Max
16
12
10
8
6
Ø 3-80
Ø 7-120
Ø 12-20
- 58 %
0
- 52 %
Ø 3-20
2
- 35 %
- 54 %
4
- 43 %
Friction force (N)
14
Uncoated
Coated
Ø 12-60
Balloon size (mm)
Source: Data on file at Abbott Vascular.
Advanced shaft technology
Crescent moon balloon lumen. Increased
cross section: rapid deflation
Hydrophobic-coated guide wire
lumen: excellent trackability
Low profile
•Compatible 5F sheath
up to 7x80 balloon
•Tapered tip
•Excellent rewrap
•High quality manufacturing
22
80 cm Usable Shaft Length
Ref. No.
135 cm Usable Shaft Length Ref. No.
Balloon Diameter
[mm] Balloon
Length
[mm]
Introducer
Compatibility
[F]
Nominal
Pressure (NP)
[atm]
Rated Burst
Pressure (RBP)
[atm]
-
10303-2010312-203
20 5
10 18
-
10304-2010313-204
20 5
10 18
10300-2010305-2010314-205
20 5
9
17
10301-2010306-2010315-206
20 5
8
16
10302-2010307-2010316-207
20 5
8
16
-
10308-20
10317-20
820
6915
-
10309-20
10318-20
920
6914
-
10310-2010319-2010 20 7
7
13
-
10311-2010320-2012 20 7
5
9
-
10344-2010345-2014 20 7
5
8
-
10305-30
10314-30
530
5917
-
10306-30
10315-30
630
5816
-
10307-30
10316-30
730
5816
-
10308-30
10317-30
830
6915
-
10309-30
10318-30
930
6913
-
10310-3010319-3010 30 7
7
13
-
10311-30
-
12307 5 9
-
10303-4010312-403
40 5
10 18
-
10304-4010313-404
40 5
10 18
10300-4010305-4010314-405
40 5
9
17
10301-4010306-4010315-406
40 5
8
16
10302-4010307-4010316-407
40 5
8
16
-
10308-40
10317-40
840
6915
-
10309-40
10318-40
940
6913
-
10310-4010319-4010 40 7
7
13
-
10311-4010320-4012 40 7
5
8
-
10344-4010345-4014 40 7
5
8
-
10304-6010313-604
60 5
10 18
-
10305-60
10314-60
560
5917
-
10306-60
10315-60
660
5815
-
10307-60
10316-60
760
5815
-
10308-60
-
860
6915
-
10309-60
-
960
6913
-
10310-60
-
10607 7 13
-
10311-60
-
12607 5 8
-
10303-8010312-803
80 5
10 17
-
10304-8010313-804
80 5
10 17
-
10305-80
10314-80
580
5917
-
10306-80
10315-80
680
5814
-
10307-80
-
780
5813
-
10308-80
-
880
6913
-
10304-10010313-1004
100 5
10
16
-
10305-100
10314-100
5100
5915
-
10306-100
10315-100
6100
5813
-
10307-100
10316-100
7100
6812
-
10304-12010313-1204
120 5
10
15
-
10305-120
10314-120
5120
5914
-
10306-120
10315-120
6120
5812
-
10307-120
10316-120
7120
6812
Iliac
Jet coated balloon, shaft, tip and guide wire lumen
0.035"
• Totally coated balloon system
• Low profile
• Advanced shaft technology
23
FOXplus
One for all
PTA Catheter
Balloon Dilatation Catheters
High strength
Ordering Information
50 cm Usable
Shaft Length
Ref. No.
•Increases safety in the dilatation of calcified lesions
Controlled compliance
•Designed to minimize risk of vessel trauma thanks to a predictable diameter at a given pressure
Low profile
Compatible with a 5F sheath up to the Ø 7 mm balloon
Deflated balloon profile (measured in the middle of the balloon) - Average/Min/Max
3.0
(mm)
2.5
2.0
1.5
1.0
0.5
0.0
FOXplus
Ø 6-120
Abbott Vascular
FOXplus
Ø 7-120
Abbott Vascular
Sailor Plus
Ø 6-120
Invatec
Powerflex P3
Ø 7-100
Cordis
Opta Pro
Ø 7-100
Cordis
Opti-Plast XT
Ø 7-100
Bard
Source: Data on file at Abbott Vascular.
Advanced shaft technology
Specifically developed dual lumen shaft
•Enables reduced inflation/deflation time for an effective and
time-saving procedure
Deflation time 80% - Average/Min/Max
14.0
Time (s)
12.0
10.0
80 cm Usable Shaft Length
Ref. No.
135 cm Usable Shaft Length Ref. No.
Balloon
Diameter
[mm] Balloon
Length
[mm]
Sheath
Compatibility
[F]
Nominal
Pressure (NP)
[atm]
Rated Burst
Pressure (RBP)
[atm]
-
AP12003AP220033 20 5 10 18
-
AP12004AP220044 20 5 10 18
82360-01
AP12005
AP22005
520
5917
82362-01
AP12006
AP22006
620
5816
82364-01
AP12007
AP22007
720
5816
-
AP12008
AP22008
820
6915
-
AP12009
AP22009
920
6914
-
AP12010AP2201010 20 7 7 13
-
AP12012AP2201212 20 7 5 9
-
AP13005
AP23005
530
5917
-
AP13006
AP23006
630
5816
-
AP13007
AP23007
730
5816
-
AP13008
AP23008
830
6915
-
AP13009
AP23009
930
6913
-
AP13010AP2301010 30 7 7 13
-
AP13012
-
12307 5 9
-
AP14003AP240033 40 5 10 18
-
AP14004AP240044 40 5 10 18
82361-01
AP14005
AP24005
540
5917
82363-01
AP14006
AP24006
640
5816
82365-01
AP14007
AP24007
740
5816
-
AP14008
AP24008
840
6915
-
AP14009
AP24009
940
6913
-
AP14010AP2401010 40 7 7 13
-
AP14012AP2401212 40 7 5 8
-
AP16004AP260044 60 5 10 18
-
AP16005
AP26005
560
5917
-
AP16006
AP26006
660
5815
-
AP16007
AP26007
760
5815
-
AP16008
-
860
6915
-
AP16009
-
960
6913
-
AP16010
-
10607 7 13
-
AP16012
-
12607 5 8
-
82906-0182916-013
80 5
10 17
-
82907-0182917-014
80 5
10 17
-
AP18005
AP28005
580
5917
-
AP18006
AP28006
680
5814
-
AP18007
-
780
5813
-
AP18008
-
880
6913
-
82908-0182918-014
100 5
10 16
-
82910-01
82920-01
5100
5915
-
82912-01
82922-01
6100
5813
-
82914-01
82924-01
7100
6812
-
82909-0182919-014
120 5
10 15
-
82911-01
82921-01
5120
5914
-
82913-01
82923-01
6120
5812
-
82915-01
82925-01
7120
6812
Iliac
Rated Burst Pressure up to 18 bar
0.035"
8.0
6.0
4.0
2.0
• High strength
0.0
FOXplus
Ø 6-120
Abbott Vascular
FOXplus
Ø 7-100
Abbott Vascular
Sailor Plus
Ø 6-120
Invatec
Powerflex P3
Ø 7-100
Cordis
Opta Pro
Ø 7-100
Cordis
Opti-Plast XT
Ø 7-100
Bard
• Low profile
Source: Data on file at Abbott Vascular.
• Advanced shaft technology
24
25
Omnilink Elite
Setting a new standard in iliac treatment
Balloon Expandable Stent Systems
Peripheral Stent System
SHEATH COMPATIBILITY
•Decreased risk of vascular complications
1
Max Profile (mm)
2.50
•Less need to change introducer sheaths
for faster procedures and reduced cost1, 2
2.00
1.50
1.00
80 cm Usable Shaft Length Ref. No. Smaller
0.50
•Shorter compression time1, 3
Ordering Information
0.00
Omnilink Elite
PALMAZ
GENESIS
Express
Vascular LD
Scuba
Chromaxx
Competitors
135 cm Usable Shaft Length
Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Nominal
Pressure (NP)
[atm]
Rated Burst
Pressure (RBP)
[atm] 11000-12
11007-12
11001-12
11008-12
11002-12
11009-12
11003-12
11010-12
4
5
6
7
126
126
126
126
1114
1114
1116
1116
11000-16
11007-16
11001-16
11008-16
11002-16
11009-16
11003-16
11010-16
4
5
6
7
166
166
166
166
1114
1114
1116
1116
11000-19
11007-19
11001-19
11008-19
11002-19
11009-19
11003-19
11010-19
11004-19
11011-19
11005-19
11012-19
11006-19
11013-19
4
5
6
7
8
9
10
196
196
196
196
196
196
196
1114
1114
1116
1116
1116
1116
1116
11001-29
11008-29
11002-29
11009-29
11003-29
11010-29
11004-29
11011-29
11005-29
11012-29
11006-29
11013-29
5
6
7
8
9
10
296
296
296
296
296
296
1114
1116
1116
1116
1116
1116
11001-39
11008-39
11002-39
11009-39
11003-39
11010-39
11004-39
11011-39
11005-39
11012-39
11006-39
11013-39
5
6
7
8
9
10
396
396
396
396
396
396
1114
1116
1116
1116
1116
1116
11001-59
11008-59
11002-59
11009-59
11003-59
11010-59
11004-59
11011-59
11005-59
11012-59
5
6
7
8
9
596
596
596
596
596
1114
1116
1116
1116
1116
Iliac
3.00
Max Profile of the Distal Stent
Delivery System (SDS)
Larger
6F sheath compatible
across all sizes
0.035"
Source: Data on file at Abbott Vascular.
Delivery Force
500
More Difficult
Excellent deliverability
•Dual-lumen catheterprovides strong push
•Dual-layer balloon withexcellent stent
retention
400
350
DELIVERABILITY
•Low-profile tip
Maximum Track Force (g)
450
300
250
200
150
100
0
Easier
50
Omnilink Elite
PALMAZ
GENESIS
Express
Vascular LD
Scuba
Chromaxx
Competitors
Source: Data on file at Abbott Vascular.
200
Expanded Stent Flexibility
Less
Flexibility without
compromising strength
180
•High RBP
•No compromise in strength or radiopacity
FLEXIBILITY
120
100
80
Large crescent shape
contrast lumen
60
40
20
0
More
•Proven4 flexible stent design
Stiffness (gf)
140
•Thin CoCr stent struts
Dual-lumen
catheter shaft
Separate guide
wire lumen
160
Omnilink Elite
PALMAZ
GENESIS
Express
Vascular LD
Scuba
CoCr
material
Dual-layer balloon
Chromaxx
Five-fold wrap balloon
Competitors
Source: Data on file at Abbott Vascular.
1. M
etz D, Meyer F, Touati C et al. Am Heart J 1997;134(1):131-137.
2. T
alley JD, Mauldin PD, Becker ER. J Interv Cardiol 1995;8(4):345-353.
3. B
üchler JR, Ribeiro EE, Falcão JL et al. J Interven Cardiol 2008;21(1):50-55
4. Source: Data on file at Abbott Vascular.
MULTI-LINK
stent design
• Excellent radiopacity
• Superb flexibility
Soft tip
• Low profile
26
27
Absolute Pro
Delivering absolute performance
Peripheral Self-Expanding Stent System
Self-Expanding Stent Systems
Smoother stent with lower fracture rate1
Ordering Information
•Stent flexibility
•Stent fracture resistance in both bending and axial modes
A
B
A. 8.0x60 mm Absolute – Abbott Vascular
B. 8.0x60 mm Competitor
Superior deliverability1
The innovative triaxial technology with I-BEAM laser-cut hypotube ensures:
•Improved kink resistance
•Accurate stent placement and deployment
80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length
Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Reference Vessel
Diameter
[mm] 1011914-0201011920-020
1011915-0201011921-020
1011916-0201011922-020
1011917-0201011923-020
1011918-0201011924-020
1011919-0201011925-020
5
6
7
8
9
10
20
20
20
20
20
20
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
1011914-0301011920-030
1011915-0301011921-030
1011916-0301011922-030
1011917-0301011923-030
1011918-0301011924-030
1011919-0301011925-030
5
6
7
8
9
10
30
30
30
30
30
30
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
1011914-0401011920-040
1011915-0401011921-040
1011916-0401011922-040
1011917-0401011923-040
1011918-0401011924-040
1011919-0401011925-040
5
6
7
8
9
10
40
40
40
40
40
40
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
1011914-0601011920-060
1011915-0601011921-060
1011916-0601011922-060
1011917-0601011923-060
1011918-0601011924-060
1011919-0601011925-060
5
6
7
8
9
10
60
60
60
60
60
60
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
1011914-0801011920-080
1011915-0801011921-080
1011916-0801011922-080
1011917-0801011923-080
1011918-0801011924-080
1011919-0801011925-080
5
6
7
8
9
10
80
80
80
80
80
80
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
1011914-1001011920-100
1011915-1001011921-100
1011916-1001011922-100
1011917-1001011923-100
1011918-1001011924-100
1011919-1001011925-100
5
6
7
8
9
10
100 6
100 6
100 6
100 6
100 6
100 6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
Iliac
The Absolute stent design, material and surface finish assure:
0.035"
I-BEAM laser-cut hypotube
Stabilizing Sheath
Retracting Sheath
• Proven1 clinical outcomes2-4
• Fracture resistance2-5
1. Source: Data on file at Abbott Vascular.
2. M. Schillinger et al. / NEJM; Vol 354, N18: 1879-1888 /Absolute Vienna Trial
3. M. Schillinger / Circulation 2007; 115:2745-2749
4. S. Sabeti / J Endovasc Ther 2007; 14:431-437
5.O. Schlager et al / J Endovasc Ther 2005; 12:676-684
6. Comparison to Absolute Peripheral Self-Expanding Stent System - Source: Tests performed by and data on file at Abbott Vascular.
28
• Superior deliverability6
29
Absolute Pro LL
Delivering absolute performance
– Extending our legacy
Peripheral Self-Expanding Stent System
Self-Expanding Stent Systems
Clinically proven1 to treat long SFA lesions2-4
Ordering Information
es
nt
D
Ste
Fracture
Resistance
l
ria
ate
Superb durability
M
nt
Ste
ign
•Quality of life significantly improved after Absolute stenting compared to PTA
80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length
Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Reference Vessel
Diameter
[mm] 1012008-1201012014-120
1012009-1201012015-120
1012010-1201012016-120
1012011-1201012017-120
5
6
7
8
120 6
120 6
120 6
120 6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
1012008-1501012014-150
1012009-1501012015-150
1012010-1501012016-150
1012011-1501012017-150
5
6
7
8
150 6
150 6
150 6
150 6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
Iliac
•Lower binary restenosis rate and sustained clinical benefit with Absolute stent compared with PTA
0.035"
Surface Finish
•Excellent stent fracture resistance2-5
-Stent material and stent design for outstanding flexibility and vessel conformability
-Advanced stent electro and micro polish for optimal surface finish to enhance stent durability
Uncompromised deliverability1
Triaxial
Technology
•Triaxial technology with:
-Stabilizing sheath to absorb stored energy and minimize friction during deployment
-I-Beam laser-cut hypotube for longitudinal strength, flexibility and pushability during stent delivery
•Ergonomic handle for easy one-handed, controlled deployment
Now available in 120 mm and 150 mm lengths*
120 mm
150 mm
* Artwork shown not to scale.
• Clinically proven to treat long SFA lesions2-4
• Superb durability2-5
• Uncompromised deliverability
1. Source: Data on file at Abbott Vascular.
2. M. Schillinger et al. / NEJM; Vol 354, N18: 1879-1888 /Absolute Vienna Trial
3. M. Schillinger / Circulation 2007; 115:2745-2749
4. S. Sabeti / J Endovasc Ther 2007; 14:431-437
5.O. Schlager et al / J Endovasc Ther 2005; 12:676-684
30
31
Hi-Torque Command ES
An optimal material fusion for BTK success
Family of .014" Peripheral Guide Wire
Guide Wires
Hybrid workhorse guide wire, specifically designed for
optimal BTK performance
Ordering Information
Dual metal technology, combining the advantages of Stainless Steel and Nitinol,
provides the optimal balance of control and ease of navigation for BTK procedures.
0.014"
Hi-Torque Command
Ref. No.
Wire Length
[cm]
Wire Size
[inch]
Tip Diameter
Tip Style
[inch]
2078174
2078175
190
300
0.014
0.014
0.014
0.014
Tip Stiffness
[g]
Shapeable3.5
Shapeable3.5
Distal Nitinol end for superb
flexibility and tip durability
Stainless steel body for excellent
torque and support
• Maintains 1-1 torque over the length of the wire
• Handling and control improved by hydrophobic coating
•
Two different support levels:
HT Command, HT Command ES (for extra support)
•Ensures smooth
device compatibility
SFA
Tip Load at 10 mm
4.5
4.09
4.0
3.45
3.5
Tip load (grams)
Transitionless
weld for uniform
support without
stress points
• Two different levels of tip load:
• 2.8 g
• 3.5 g
•Less traumatic and easier to navigate in tortuous
anatomies
• Hydrophilic coating on a radiopaque polymer
cover for improved lubricity, gliding and visibility
3.0
2.67
2.77
HT Pilot 150
HT Command
2.5
2.0
1.5
1.0
HT Command Support Curve vs Pilot 150
0.5
0
12
HT Command ES
HT Pilot 200
Source: Data on file at Abbott Vascular.
10
Force value (g)
8
6
4
HT Command ES
HT Command
HT Pilot 150
2
Distance from tip (mm)
240
210
192
168
144
120
96
108
84
72
60
48
36
28
24
20
16
8
12
4
0
0
Nitinol core with
parabolic grind for
excellent torque
and control
Shapeable Nitinol tip
for improved
tip durability
3 cm distal platinum
radiopaque coils
Source: Data on file at Abbott Vascular.
32
33
Hi-Torque Connect
The power to connect
Family of .018" Peripheral Guide Wires
Guide Wires
Three distinct wires with:
Ordering Information
• Different support levels to provide options for lesion crossing in straight to tortuous anatomies
• Choice of increasing tip loads and penetration power to maximise crossing in soft to heavily calcified lesions
• Outstanding torque performance and control especially in contralateral approach
Support
Hi-Torque Connect
Tip Diameter
Tip Shape
[inch]
1012587 145
1012588 195
1012589 300
0.018
0.018
0.018
Hi-Torque Connect Flex
Ref. No.
Tip Diameter
Tip Shape
[inch]
Wire Length
[cm]
Tip Stiffness
[g]
Straight4
Straight4
Straight4
1012590 145
1012591 195
1012592 300
0.018
0.018
0.018
Hi-Torque Connect 250T
Ref. No.
Tip Diameter
Tip Shape
[inch]
Tip Stiffness
[g]
Straight12
Straight12
Straight12
Hi-Torque Connect 250T
Wire Support
Supportive workhorse wire.
Ideal for straight run-off with soft
to moderately calcified occlusions
in focal stenoses.
Wire Length
[cm]
Wire Length
[cm]
1012593 145
1012594 195
1012595 300
0.0125
0.0125
0.0125
Tip Stiffness
[g]
Straight30
Straight30
Straight30
SFA
Hi-Torque Connect
Hi-Torque Connect
Ref. No.
0.018"
Hi-Torque Connect Flex
Distance from Distal Tip
Hi-Torque Connect Flex
Penetration Power
250 kg/in2
Trackable workhorse wire.
Increased tip load and flexibility for navigating
tortuous anatomies with acute take-off and
moderately calcified occlusions.
Hi-Torque Connect
52 kg/in2
17 kg/in2
Hi-Torque
Connect
Hi-Torque Connect 250T
Hi-Torque
Connect Flex
Hi-Torque
Connect 250T
Tip Load
Hi-Torque Connect Flex
Specialty CTO wire.
30 g
Specially designed .0125" tapered tip with 30
gram tip load and increased penetration power,
ideal for long, heavy calcifications.
12 g
4g
Hi-Torque
Connect
Hi-Torque
Connect Flex
Hi-Torque
Connect 250T
Hi-Torque Connect 250T
Tests performed by and data on file at Abbott Vascular.
34
35
Hi-Torque Winn
Feel. Cross. Winn.
Family of Chronic Occlusion Guide Wires
Guide Wires
The new standard in guide wires designed
for chronic occlusions
Ordering Information
Hi-Torque Winn family’s unique design offers a selection of tip loads with excellent
tactile feel, maximum torque and pushability for intraluminal crossing of challenging
below-the-knee chronic occlusions.1
0.014"
Hi-Torque Winn 40
Tip Shape
Ref. No.
1012466
1012467
Straight4.8
Straight4.8
Hi-Torque Winn 80
Tip Shape
Ref. No.
Excellent tactile feel
Know where you are
Maximum torque
Be in control
1012468
1012469
1012474
1012475
Tip Stiffness
[g]
Tip Diameter
[in]
Wire Length
[cm]
0.012 190
0.012 300
Tip Diameter
[in]
Wire Length
[cm]
0.012 190
0.012 300
Tip Diameter
[in]
Wire Length
[cm]
Tapered13.0 0.009 190
Tapered13.0 0.009 300
SFA
• Transitionless DURASTEEL core
taper for maximum torque and
excellent pushability
• Intermediate hydrophilic polymer
sleeve for smooth chronic
occlusion crossing
Tip Stiffness
[g]
Straight9.7
Straight9.7
Hi-Torque Winn 200T
Tip Shape
Ref. No.
• Exposed shapeable tip coils for
maximum tactile feedback
• DURASTEEL Core-to-tip for tip
shape retention, control and
precise steering
Tip Stiffness
[g]
Unique tip offerings
Cross confidently
• Breakthrough advancement in the art of chronic occlusion treatment
• 3 tips with varying tip diameter and increasing tip stiffness to cross challenging lesions
Winn 40
Winn 80
Winn 200T
Feel. Cross. Winn.
• Excellent tactile feel
• Maximum torque
• Unique tip offerings
•Ideal for probing
and sliding
•Stiff tip ideal
for drilling
•Extra stiff tapered
tip for penetrating
Hi-Torque Winn is indicated for PTA and PTCA use.
1. Abbott Vascular physician preference testing in 39 BTK cases conducted using Hi-Torque Winn 4/10-6/10.
Illustrations not drawn to scale.
36
37
STEELCORE 18 LT
Extra support for
lower limb procedures
HI-TORQUE .018" Guide Wire
Guide Wires
Providing strong support and flexibility for a
successful crossing
Ordering Information
0.018"
STEELCORE
Tip Shape
Wire Length
Ref. No.
[cm]
One-to-one torque for navigation around vessel bends
•Provides proximal through distal support
• Marker to locate the wire accurately. Measured from the distal tip:
90 cm for the 190 cm length
100 cm for the 300 cm length
1003281* Straight
190
1003282 Straight
300
STEELCORE LT
Tip Shape
Wire Length
Ref. No.
[cm]
• Available in 190 and 300 cm length
1007709* 1007709-J* Straight
J
190
190
• Available in two transition lengths
1007710 1007710-J Straight
J
300
300
Torque devices sold separately and in packs of ten (Ref. No. 22215).
*DOC guide wire extension compatible.
Grams of force at 5 mm
SFA
Tip stiffness
70
60
50
40
30
20
10
0
HI-TORQUE
SteelCore 18
HI-TORQUE
SteelCore 18 LT
Leading competitive
(.018" supportive wire)
Source: Data on file at Abbott Vascular.
HI-TORQUE SteelCore 18 (with 5 cm platinum/nickel tip coil)
Shapeable, flexible tip
Proximal through distal support
Proximal markers assist in determining wire position relative to guide/sheath tip
MICROGLIDE coating provides low friction
and enhanced trackability
Radiopaque platinum tip coil
helps provide accurate positioning
Longer transitions are ideally suited
for angled or acute take-offs
HI-TORQUE SteelCore 18 LT (with 12.5 cm platinum/nickel tip coil)
38
Shapeable, durable tip
39
SUPRA CORE 35
Extra support for
lower limb procedures
HI-TORQUE .035" Guide Wire
Guide Wires
Steerability and support in a .035" peripheral
guide wire
Ordering Information
Supportive .035" wire with soft atraumatic tip
•Able to facilitate device placement and exchange throughout an entire procedure
• Provide the foundation for nearly all your diagnostic and therapeutic needs in the
peripheral anatomy
0.035"
Ref. No.
Tip Shape
Wire Length
[cm]
1002703 Straight
145
1002703-01 Straight
190
1002703-02 Straight
300
Torque devices sold separately and in packs of ten (Ref. No. 1003279).
• Designed to ensure successful clinical performance and successful patient outcomes
• Amplatz support with Wholey tip
• One-to-one torque response provides exceptional steerability
SFA
• Radiopaque markers to control wire stability during the procedure
• Available in 145, 190 and 300 cm length
One-to-one torque response
provides exceptional
steerability
Proximal .025" outer diameter ensures
.035" compatible device exchanges
40
MICROGLIDE coating reduces friction,
improving wire movement and catheter
trackability
Exclusively designed 17 cm, tapered .025" core allows
support with flexibility for varied device delivery and
applications Widow
Radiopaque tip allows excellent
guide wire placement
Shapeable, atraumatic tip
41
Armada 35
A Step Ahead
PTA Catheter
Balloon Dilatation Catheters
Designed to streamline your procedure from start to finish
Ordering Information
Armada 35 is designed to optimize PTA performance at each stage of your procedure.
The combination of finesse and power reduces the need for specialty balloons and keeps
you a step ahead in your cases.
80 cm
Catheter Length
Ref. No.
A comprehensive portfolio* with each size range engineered for specific clinical situations.
•Small lesion entry profile
•Strong pushability
•High RBP (up to 28 bar)
Workhorse and
Pre-Dilatation
•Diameters up to 14 mm
•Low sheath size compatibility (6F sheath compatible up to 12 mm)
•Fast deflation times
Large
Diameter
Frontline performance even in high pressure situations
Unmatched pushability with the lowest tip and balloon crossing profiles** to enter and cross lesions without
compromising RBP.
Push Transmission (%)
Lesion Crossing Profile (mm)
53
42
41
1.64
E
D
A = EverCross
B = Admiral Xtreme
1.85
1.86
39
30
ARMADA
35
1.73 1.77
C
B
28
F
25
A
C = Dorado
D = Powerflex P3
1.88
24
22
18
ARMADA
35
1.87
A
17
B
15
F
E = Rival
F = Ultra-thin Diamond
C
15
14
D
E
= RBP
(bar)
135 cm
Catheter Length
Ref. No.
Balloon
Diameter
[mm]
Balloon
Min Sheath
Length
Size [F]
[mm]
Nominal
Pressure
[atm]
RBP
[atm]
B1030-020B2030-020 3.0 20 5
B1030-040B2030-040 3.0 40 5
8 28
8 28
B1040-020B2040-020 4.0
B1040-040B2040-040 4.0
B1040-060B2040-060 4.0
B1040-080B2040-080 4.0
B1040-100B2040-100 4.0
B1040-120B2040-120 4.0
20 5
40 5
60 5
80 5
100 5
120 5
8
8
8
8
8
8
25
25
25
20
20
20
B1050-020B2050-020 5.0
B1050-040B2050-040 5.0
B1050-060B2050-060 5.0
B1050-080B2050-080 5.0
B1050-100B2050-100 5.0
B1050-120B2050-120 5.0
20 5
40 5
60 5
80 5
100 5
120 5
8
8
8
8
8
8
22
22
20
18
18
18
B1060-020B2060-020 6.0
B1060-040B2060-040 6.0
B1060-060B2060-060 6.0
B1060-080B2060-080 6.0
B1060-100B2060-100 6.0
B1060-120B2060-120 6.0
20 5
40 5
60 5
80 5
100 5
120 5
6
6
6
6
6
6
20
20
18
16
16
16
B1070-020B2070-020 7.0
B1070-040B2070-040 7.0
B1070-060B2070-060 7.0
B1070-080B2070-080 7.0
B1070-100B2070-100 7.0
B1070-120B2070-120 7.0
20 5
40 5
60 5
80 5
100 6
120 6
6
6
6
6
6
6
15
15
15
14
14
14
B1080-020B2080-020 8.0
B1080-040B2080-040 8.0
B1080-060B2080-060 8.0
B1080-080B2080-080 8.0
20
40
60
80
6
6
6
6
6
6
6
6
15
15
14
13
B1090-020B2090-020 9.0
B1090-040B2090-040 9.0
B1090-060B2090-060 9.0
B1090-080B2090-080 9.0
20
40
60
80
6
6
6
6
6
6
6
6
14
13
12
12
B1100-020B2100-020 10.0 20
B1100-040B2100-040 10.0 40
B1100-060B2100-060 10.0 60
B1100-080B2100-080 10.0 80
6
6
6
6
6
6
6
6
13
12
11
10
B1120-020B2120-020 12.0 20
B1120-040B2120-040 12.0 40
B1120-060B2120-060 12.0 60
B1120-080B2120-080 12.0 80
6
6
6
6
4
4
4
4
10
10
9
9
B1140-020B2140-020 14.0 20
B1140-040B2140-040 14.0 40
B1140-060B2140-060 14.0 60
B1140-080B2140-080 14.0 80
7
7
7
7
4
4
4
4
8
8
7
7
SFA
Engineered to treat the broadest range of lesions
0.035"
6F sheath
compatible up to 12 mm
* Source: AV Market Intelligence among top competitive devices.
**Based on tip and balloon crossing profile measurements and pushability performance bench tests among competitors tested. (Powerflex P3, Ultrathin Diamond, Admiral Xtreme, Dorado, Rival, EverCross)
42
43
Armada 35 LL
A Step Ahead
PTA Catheter
Balloon Dilatation Catheters
Designed to streamline your procedure from start to finish
Ordering Information
Armada 35 LL is designed to optimize PTA performance at each stage of your procedure.
The combination of finesse and power reduces the need for specialty balloons and keeps
you a step ahead in your cases.
80 cm
Catheter Length
Ref. No.
0.035"
135 cm
Catheter Length
Ref. No.
Balloon
Diameter
[mm]
Balloon
Min Sheath
Length
Size [F]
[mm]
Nominal
Pressure
[atm]
RBP
[atm]
8 20
8 18
8 18
Engineered to treat the broadest range of lesions
B1050-150B2050-150 5.0 150 5
B1050-200B2050-200 5.0 200 5
B1050-250B2050-250 5.0 250 5
8 18
8 18
8 16
A comprehensive portfolio* with each size range engineered for specific clinical situations.
B1060-150B2060-150 6.0 150 5
B1060-200B2060-200 6.0 200 6
B1060-250B2060-250 6.0 250 6
6 16
6 14
6 12
B1070-150B2070-150 7.0 150 6
B1070-200B2070-200 7.0 200 6
6 14
6 13
Workhorse and
Pre-Dilatation
•Small lesion entry profile
•Strong pushability
Long
Length (LL)
•Lengths up to 250 mm
• Low lesion crossing profiles
• Strong pushability
• Controlled 3D compliance
SFA
B1040-150B2040-150 4.0 150 5
B1040-200B2040-200 4.0 200 5
B1040-250B2040-250 4.0 250 5
6F sheath
Frontline performance even in high pressure situations
Unmatched pushability with the lowest tip and balloon crossing profiles** to enter and cross lesions without
compromising RBP.
Push Transmission (%)
Lesion Crossing Profile (mm)
53
42
41
1.64
ARMADA
35
E
D
A = EverCross
B = Admiral Xtreme
1.73 1.77
1.85
1.86
39
30
C
B
compatible up to 7 x 200 mm
28
F
25
A
C = Dorado
D = Powerflex P3
1.88
15
14
D
E
24
22
18
ARMADA
35
1.87
A
17
B
15
F
E = Rival
F = Ultra-thin Diamond
C
= RBP
(bar)
* Source: AV Market Intelligence among top competitive devices.
**Based on tip and balloon crossing profile measurements and pushability performance bench tests among competitors tested. (Powerflex P3, Ultrathin Diamond, Admiral Xtreme, Dorado, Rival, EverCross)
44
45
FOXsv
Mastering the small vessel challenge
Balloon Dilatation Catheters
High pressure balloon
Profile – 4F introducer compatible
High Rated Burst Pressure
– up to 22 bar
Low entry profile
•Eases insertion through tight or occluded lesions
•Enables safer treatment of highly
calcified lesions
Dual lumen shaft design – Rapid inflation/deflation
•Enables to shorten procedure and reduce patient discomfort
Deflation time 80% – Average/Min/Max
Time (s)
25.0
20.0
15.0
10.0
5.0
0.0
Abbott Vascular
FOXsv
Ø 4-120
Abbott Vascular
Submarine Plus
Ø 4-120
Invatec
Amphirion*
Ø 4-120
Invatec
Savvy
Ø 4-100
Cordis
Symmetry
Ø 4-100
Boston Scientific
Source: Data on file at Abbott Vascular.
* This measurement runs out of maximum time record of 20 s.
Excellent balloon rewrap – Minimal deflated balloon profile
•Enables better recrossing of lesions/stents
•Eases insertion and withdrawal through introducer sheaths
12.0
Ordering Information
90 cm Usable
Shaft Length
Ref. No.
135 cm Usable
Shaft Length Ref. No.
150 cm Usable
Shaft Length Ref. No.
Balloon Diameter
[mm] 82158-54-0182157-54-01-
4.0
82168-54-0182167-54-01-
5.0
82144-54-01-
83143-54-012.0
82373-54-01-
83372-54-012.5
82150-54-01-
83149-54-013.0
82160-54-0182159-54-01-
4.0
82170-54-0182169-54-01-
5.0
82180-54-0182179-54-01-
6.0
82146-54-01-
83145-54-012.0
82375-54-01-
83374-54-012.5
82152-54-01-
83151-54-013.0
82162-54-0182161-54-01-
4.0
82172-54-0182171-54-01-
5.0
82148-54-01-
83147-54-012.0
82377-54-01-
83376-54-012.5
82154-54-01-
83153-54-013.0
82164-54-0182163-54-01-
4.0
82174-54-0182173-54-01-
5.0
82184-54-0182183-54-01-
6.0
82198-54-01-
83197-54-012.0
82379-54-01-
83378-54-012.5
82156-54-01-
83155-54-013.0
82166-54-0182165-54-01-
4.0
82176-54-0182175-54-01-
5.0
82186-54-0182185-54-01-
6.0
82946-54-01-
83964-54-012.0
82949-54-01-
83967-54-012.5
82952-54-01-
83970-54-013.0
82955-54-0182973-54-01-
4.0
82958-54-0182976-54-01-
5.0
82961-54-0182979-54-01-
6.0
82947-54-01-
83965-54-012.0
82950-54-01-
83968-54-012.5
82953-54-01-
83971-54-013.0
82956-54-0182974-54-01-
4.0
82959-54-0182977-54-01-
5.0
82962-54-0182980-54-01-
6.0
82948-54-01-
83966-54-012.0
82951-54-01-
83969-54-012.5
82954-54-01-
83972-54-013.0
82957-54-0182975-54-01-
4.0
82960-54-0182978-54-01-
5.0
82963-54-0182981-54-01-
6.0
Balloon Length [mm]
Sheath
Compatibility
[F]
Nominal
Pressure (NP)
[atm]
Rated Burst
Pressure (RBP)
[atm]
15
15
4
4
6
6
20
20
20
20
20
20
20
20
4
4
4
4
4
4
12
12
8
6
6
6
22
22
22
20
20
17
30
30
30
30
30
4
4
4
4
4
12
12
8
6
6
22
22
20
20
20
40
40
40
40
40
40
4
4
4
4
4
4
12
12
8
6
6
6
22
22
20
20
20
17
60
60
60
60
60
60
4
4
4
4
4
4
12
12
8
6
6
6
22
22
20
18
17
17
80
80
80
80
80
80
4
4
4
4
4
4
12
12
8
6
6
6
22
22
20
16
16
15
100
100
100
100
100
100
4
4
4
4
4
4
12
12
8
6
6
6
22
22
20
16
16
15
120
120
120
120
120
120
4
4
4
4
4
4
12
12
8
6
6
6
22
22
20
16
16
15
SFA
PTA Catheter
FOXsv
Ø 4-100
0.018"
Maximum withdrawal force after inflation up to 20 bar – Average/Min/Max
Force (N)
10.0
8.0
6.0
4.0
• Designed for small vessels
2.0
0.0
FOXsv
Ø 4-100
4F introducer
Abbott Vascular
FOXsv
Ø 4-120
4F introducer
Abbott Vascular
Submarine Plus
Ø 4-120
4F introducer
Invatec
Amphirion
Ø 4-120
4F introducer
Invatec
Savvy
Ø 4-100
5F introducer
Cordis
Symmetry
Ø 4-100
5F introducer
Boston Scientific
Source: Data on file at Abbott Vascular.
46
• Optimized hemodynamics
• Conformability
47
FOXcross
Designed to get you there
PTA Catheter
Balloon Dilatation Catheters
Totally coated balloon system – reduced friction
Ordering Information
50 cm Usable
Shaft Length
Ref. No.
•Improved trackability
•Improved crossability, especially in calcified long lesions
•Reduced pull-back force
Effect of jet coating on balloon system
Average/Min/Max
16
12
10
8
6
Ø 3-80
Ø 7-120
Ø 12-20
- 58 %
0
- 52 %
Ø 3-20
2
- 35 %
- 54 %
4
- 43 %
Friction force (N)
14
Uncoated
Coated
Ø 12-60
Balloon size (mm)
Source: Data on file at Abbott Vascular.
Advanced shaft technology
Crescent moon balloon lumen. Increased
cross section: rapid deflation
Hydrophobic-coated guide wire
lumen: excellent trackability
Low profile
•Compatible 5F sheath
up to 7x80 balloon
•Tapered tip
•Excellent rewrap
•High quality manufacturing
48
80 cm Usable Shaft Length
Ref. No.
135 cm Usable Shaft Length Ref. No.
Balloon Diameter
[mm] Balloon
Length
[mm]
Introducer
Compatibility
[F]
Nominal
Pressure (NP)
[atm]
Rated Burst
Pressure (RBP)
[atm]
-
10303-2010312-203
20 5
10 18
-
10304-2010313-204
20 5
10 18
10300-2010305-2010314-205
20 5
9
17
10301-2010306-2010315-206
20 5
8
16
10302-2010307-2010316-207
20 5
8
16
-
10308-20
10317-20
820
6915
-
10309-20
10318-20
920
6914
-
10310-2010319-2010 20 7
7
13
-
10311-2010320-2012 20 7
5
9
-
10344-2010345-2014 20 7
5
8
-
10305-30
10314-30
530
5917
-
10306-30
10315-30
630
5816
-
10307-30
10316-30
730
5816
-
10308-30
10317-30
830
6915
-
10309-30
10318-30
930
6913
-
10310-3010319-3010 30 7
7
13
-
10311-30
-
12307 5 9
-
10303-4010312-403
40 5
10 18
-
10304-4010313-404
40 5
10 18
10300-4010305-4010314-405
40 5
9
17
10301-4010306-4010315-406
40 5
8
16
10302-4010307-4010316-407
40 5
8
16
-
10308-40
10317-40
840
6915
-
10309-40
10318-40
940
6913
-
10310-4010319-4010 40 7
7
13
-
10311-4010320-4012 40 7
5
8
-
10344-4010345-4014 40 7
5
8
-
10304-6010313-604
60 5
10 18
-
10305-60
10314-60
560
5917
-
10306-60
10315-60
660
5815
-
10307-60
10316-60
760
5815
-
10308-60
-
860
6915
-
10309-60
-
960
6913
-
10310-60
-
10607 7 13
-
10311-60
-
12607 5 8
-
10303-8010312-803
80 5
10 17
-
10304-8010313-804
80 5
10 17
-
10305-80
10314-80
580
5917
-
10306-80
10315-80
680
5814
-
10307-80
-
780
5813
-
10308-80
-
880
6913
-
10304-10010313-1004
100 5
10
16
-
10305-100
10314-100
5100
5915
-
10306-100
10315-100
6100
5813
-
10307-100
10316-100
7100
6812
-
10304-12010313-1204
120 5
10
15
-
10305-120
10314-120
5120
5914
-
10306-120
10315-120
6120
5812
-
10307-120
10316-120
7120
6812
SFA
Jet coated balloon, shaft, tip and guide wire lumen
0.035"
• Totally coated balloon system
• Low profile
• Advanced shaft technology
49
FOXplus
One for all
PTA Catheter
Balloon Dilatation Catheters
High strength
Ordering Information
50 cm Usable
Shaft Length
Ref. No.
•Increases safety in the dilatation of calcified lesions
Controlled compliance
•Designed to minimize risk of vessel trauma thanks to a predictable diameter at a given pressure
Low profile
Compatible with a 5F sheath up to the Ø 7 mm balloon
Deflated balloon profile (measured in the middle of the balloon) - Average/Min/Max
3.0
(mm)
2.5
2.0
1.5
1.0
0.5
0.0
FOXplus
Ø 6-120
Abbott Vascular
FOXplus
Ø 7-120
Abbott Vascular
Sailor Plus
Ø 6-120
Invatec
Powerflex P3
Ø 7-100
Cordis
Opta Pro
Ø 7-100
Cordis
Opti-Plast XT
Ø 7-100
Bard
Source: Data on file at Abbott Vascular.
Advanced shaft technology
Specifically developed dual lumen shaft
•Enables reduced inflation/deflation time for an effective and
time-saving procedure
Deflation time 80% - Average/Min/Max
14.0
Time (s)
12.0
10.0
80 cm Usable Shaft Length
Ref. No.
135 cm Usable Shaft Length Ref. No.
Balloon
Diameter
[mm] Balloon
Length
[mm]
Sheath
Compatibility
[F]
Nominal
Pressure (NP)
[atm]
Rated Burst
Pressure (RBP)
[atm]
-
AP12003AP220033 20 5 10 18
-
AP12004AP220044 20 5 10 18
82360-01
AP12005
AP22005
520
5917
82362-01
AP12006
AP22006
620
5816
82364-01
AP12007
AP22007
720
5816
-
AP12008
AP22008
820
6915
-
AP12009
AP22009
920
6914
-
AP12010AP2201010 20 7 7 13
-
AP12012AP2201212 20 7 5 9
-
AP13005
AP23005
530
5917
-
AP13006
AP23006
630
5816
-
AP13007
AP23007
730
5816
-
AP13008
AP23008
830
6915
-
AP13009
AP23009
930
6913
-
AP13010AP2301010 30 7 7 13
-
AP13012
-
12307 5 9
-
AP14003AP240033 40 5 10 18
-
AP14004AP240044 40 5 10 18
82361-01
AP14005
AP24005
540
5917
82363-01
AP14006
AP24006
640
5816
82365-01
AP14007
AP24007
740
5816
-
AP14008
AP24008
840
6915
-
AP14009
AP24009
940
6913
-
AP14010AP2401010 40 7 7 13
-
AP14012AP2401212 40 7 5 8
-
AP16004AP260044 60 5 10 18
-
AP16005
AP26005
560
5917
-
AP16006
AP26006
660
5815
-
AP16007
AP26007
760
5815
-
AP16008
-
860
6915
-
AP16009
-
960
6913
-
AP16010
-
10607 7 13
-
AP16012
-
12607 5 8
-
82906-0182916-013
80 5
10 17
-
82907-0182917-014
80 5
10 17
-
AP18005
AP28005
580
5917
-
AP18006
AP28006
680
5814
-
AP18007
-
780
5813
-
AP18008
-
880
6913
-
82908-0182918-014
100 5
10 16
-
82910-01
82920-01
5100
5915
-
82912-01
82922-01
6100
5813
-
82914-01
82924-01
7100
6812
-
82909-0182919-014
120 5
10 15
-
82911-01
82921-01
5120
5914
-
82913-01
82923-01
6120
5812
-
82915-01
82925-01
7120
6812
SFA
Rated Burst Pressure up to 18 bar
0.035"
8.0
6.0
4.0
2.0
• High strength
0.0
FOXplus
Ø 6-120
Abbott Vascular
FOXplus
Ø 7-100
Abbott Vascular
Sailor Plus
Ø 6-120
Invatec
Powerflex P3
Ø 7-100
Cordis
Opta Pro
Ø 7-100
Cordis
Opti-Plast XT
Ø 7-100
Bard
• Low profile
Source: Data on file at Abbott Vascular.
• Advanced shaft technology
50
51
Xpert
The one and only
Stent System
Self-Expanding Stent Systems
The world`s first 4F compatible self-expanding stent
system1, specifically designed for small vessels with
focus on hemodynamics
Ordering Information
Each stent diameter was specifically developed to guarantee a Nitinol/vessel wall coverage
of maximum 20%.
Designed for small vessels
Xpert has a homogeneous and diameter independent constant arterial surface coverage
(each stent diameter is specifically designed). The wall coverage is reduced compared to
other NiTi stents.
Radial force
Radial Force [N/cm]
Higher radial force compared to other
.018" guidewire systems. No
compromise in radial force compared
to .035" guidewire systems.
1.0
0.8
120 cm Usable
Shaft Length Ref. No.
Stent
Diameter
[mm] Stent Length [mm] Introducer Compatibility
[F]
Reference
Vessel Diameter
[mm]
EX8S2005EX8L2005
EX8S3005EX8L3005
EX8S4005EX8L4005
EX8S6005EX8L6005
5
5
5
5
20
30
40
60
4
4
4
4
3-4
3-4
3-4
3-4
EX8S2006EX8L2006
EX8S3006EX8L3006
EX8S4006EX8L4006
EX8S6006EX8L6006
6
6
6
6
20
30
40
60
4
4
4
5
4-5
4-5
4-5
4-5
EX8S3008EX8L3008 8
EX8S4008EX8L4008 8
EX8S6008EX8L6008 8
30
40
60
5 5-7
5 5-7
5 5-7
90 cm Usable
Shaft Length
Ref. No.
Stent Length [mm] Introducer Compatibility
[F]
EX8S2003EX8L2003 3
EX8S3003EX8L3003 3
EX8S4003EX8L4003 3
20
30
40
4 2-2.5
4 2-2.5
4 2-2.5
EX8S2004EX8L2004
EX8S3004EX8L3004
EX8S4004EX8L4004
EX8S6004EX8L6004
83010-0283011-02
20
30
40
60
80
4
4
4
4
4
135 cm Usable
Shaft Length Ref. No.
Stent
Diameter
[mm] 4
4
4
4
4
Reference
Vessel Diameter
[mm]
SFA
Innovation and technology have resulted in a new generation of the Xpert small vessel stent
system, now enabling the treatment of peripheral vessels from diameter 2 mm up to 7 mm.
80 cm Usable
Shaft Length
Ref. No.
0.018"
2.5-3.5
2.5-3.5
2.5-3.5
2.5-3.5
2.5-3.5
0.6
0.4
0.2
0.0
Xpert
Ø3, 4F
Xpert
Ø4, 4F
Xpert
Ø6, 4F
Xpert
Ø8, 5F
Comp D
Ø8, 5F
0.018"
Comp A
Ø8, 6F
0.035"
Source: Data on file at Abbott Vascular.
Conformability
In tortuous anatomies, a good wall apposition ensures, that the vessel lumen is not reduced
and hemodynamics are maintained.
Optimized hemodynamics
The relative wall coverage can be compared to a standard stent in a larger vessel. The
low strut profile also contributes to optimizing the vessel lumen and minimizing the flow
disturbance. This design assures minimal reduction of vessel lumen when placed in a
small vessel.
• Designed for small vessels
• Optimized hemodynamics
Strut profile designed
for large vessels
in a large vessel
Strut profile designed
for large vessels
in a small vessel
Specifically designed
Xpert strut profile
in a small vessel
• Conformability
1. Source: Data on file at Abbott Vascular.
52
53
Xpert Pro
Slim, Tri-Layer Catheter Design
Self-Expanding Stent Systems
Self-Expanding Stent System
Ordering Information
Stent Movement During Deployment
9
Accurate stent deployment
and placement through the
advanced stabilizer coil.
8
Movement (mm)
Less
Accurate
7
6
5
4
3
4.9
2
1
0.1
5.3
3.7
More
Accurate
0
Abbott Vascular Biotronik Astron
Xpert Pro
Pulsar
Invatec Maris
OptiMed
Deep
sinus-Superflex-418
Reach*
3.9F
ngineered for excellent
E
deliverability in complex
cases with the innovative,
slim, intra-laced sheath.
Lowest† catheter system
profile for tight anatomies.
Xpert Pro
4.6F
Astron Pulsar
4.2F
Maris Deep
4.2F
sinus-SuperFlex-418
90 cm
Catheter Length
Ref. No.
135 cm
Catheter Length
Ref. No.
Stent
Diameter
[mm] Stent Length [mm] Sheath Compatibility
[F]
Reference
Vessel Diameter
[mm]
17525-20
17525-30
17525-40
17525-60
17525-80
17525-100
17538-20
17538-30
17538-40
17538-60
17538-80
17538-100
3
3
3
3
3
3
20
30
40
60
80
100
4
4
4
4
4
4
2.0 - 2.5
2.0 - 2.5
2.0 - 2.5
2.0 - 2.5
2.0 - 2.5
2.0 - 2.5
17526-20
17526-30
17526-40
17526-60
17526-80
17526-100
17539-20
17539-30
17539-40
17539-60
17539-80
17539-100
4
4
4
4
4
4
20
30
40
60
80
100
4
4
4
4
4
4
2.5 - 3.5
2.5 - 3.5
2.5 - 3.5
2.5 - 3.5
2.5 - 3.5
2.5 - 3.5
80 cm
Catheter Length
Ref. No.
120 cm
Catheter Length
Ref. No.
Stent
Diameter
[mm] Stent Length [mm] Sheath Compatibility
[F]
Reference
Vessel Diameter
[mm]
17527-20
17527-30
17527-40
17527-60
17527-80
17527-100
17540-20
17540-30
17540-40
17540-60
17540-80
17540-100
5
5
5
5
5
5
20
30
40
60
80
100
4
4
4
4
5
5
3.0 - 4.0
3.0 - 4.0
3.0 - 4.0
3.0 - 4.0
3.0 - 4.0
3.0 - 4.0
17528-20
17528-30
17528-40
17528-60
17528-80
17541-20
17541-30
17541-40
17541-60
17541-80
6
6
6
6
6
20
30
40
60
80
4
4
4
5
5
4.0 - 5.0
4.0 - 5.0
4.0 - 5.0
4.0 - 5.0
4.0 - 5.0
17529-30
17529-40
17529-60
17542-30
17542-40
17542-60
8
8
8
30
40
60
5
5
5
5.0 - 7.0
5.0 - 7.0
5.0 - 7.0
SFA
Precision*
0.018"
†Among competitors listed herein.
Sizes tested:
4 mm x 80 mm: Xpert Pro, Astron Pulsar, Maris Deep
4 mm x 100 mm: sinus-SuperFlex 418
Tests performed by and data on file at Abbott Vascular.
Optimization
Smallest diameter
available (3 mm)
to treat the most
common BTK size.**
Customized Stent Design for Each Vessel Size
Same Strut Thickness
Slim, Tri-Layer Catheter Design
Thinner Strut Thickness
Thin struts for minimal
vessel lumen reduction.
Standard stents use the
same strut thickness for
every vessel size
Xpert Pro is specifically
designed with thinner stent
struts for smaller vessels
* Tests performed by and data on file at Abbott Vascular.
**Lesion reference vessel diameter in XCELL trial was 2.8 ± 0.7. K. Roca-Singh, XCELL Trial Final Data Set, VIVA 2010.
Lesion reference vessel diameter in DESTINY trial was 2.9 ± 0.72 for BMS and 3.0 ± 0.84 for DES. M. Bosiers, BTK Stenting: The DESTINY results, LINC Asia-Pacific 2011.
DESTINY and XCELL are Investigator Sponsored Studies (ISS) – Abbott Vascular does not promote directly or indirectly any out of intended use and recommends that the IFU is read
thoroughly before the use of all devices in these studies.
54
55
Absolute Pro
Delivering absolute performance
Peripheral Self-Expanding Stent System
Self-Expanding Stent Systems
Smoother stent with lower fracture rate1
Ordering Information
•Stent flexibility
•Stent fracture resistance in both bending and axial modes
A
B
A. 8.0x60 mm Absolute – Abbott Vascular
B. 8.0x60 mm Competitor
Superior deliverability1
The innovative triaxial technology with I-BEAM laser-cut hypotube ensures:
•Improved kink resistance
•Accurate stent placement and deployment
80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length
Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Reference Vessel
Diameter
[mm] 1011914-0201011920-020
1011915-0201011921-020
1011916-0201011922-020
1011917-0201011923-020
1011918-0201011924-020
1011919-0201011925-020
5
6
7
8
9
10
20
20
20
20
20
20
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
1011914-0301011920-030
1011915-0301011921-030
1011916-0301011922-030
1011917-0301011923-030
1011918-0301011924-030
1011919-0301011925-030
5
6
7
8
9
10
30
30
30
30
30
30
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
1011914-0401011920-040
1011915-0401011921-040
1011916-0401011922-040
1011917-0401011923-040
1011918-0401011924-040
1011919-0401011925-040
5
6
7
8
9
10
40
40
40
40
40
40
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
1011914-0601011920-060
1011915-0601011921-060
1011916-0601011922-060
1011917-0601011923-060
1011918-0601011924-060
1011919-0601011925-060
5
6
7
8
9
10
60
60
60
60
60
60
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
1011914-0801011920-080
1011915-0801011921-080
1011916-0801011922-080
1011917-0801011923-080
1011918-0801011924-080
1011919-0801011925-080
5
6
7
8
9
10
80
80
80
80
80
80
6
6
6
6
6
6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
1011914-1001011920-100
1011915-1001011921-100
1011916-1001011922-100
1011917-1001011923-100
1011918-1001011924-100
1011919-1001011925-100
5
6
7
8
9
10
100 6
100 6
100 6
100 6
100 6
100 6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
6.4-8.2
7.1-9.1
SFA
The Absolute stent design, material and surface finish assure:
0.035"
I-BEAM laser-cut hypotube
Stabilizing Sheath
Retracting Sheath
• Proven1 clinical outcomes2-4
• Fracture resistance2-5
1. Source: Data on file at Abbott Vascular.
2. M. Schillinger et al. / NEJM; Vol 354, N18: 1879-1888 /Absolute Vienna Trial
3. M. Schillinger / Circulation 2007; 115:2745-2749
4. S. Sabeti / J Endovasc Ther 2007; 14:431-437
5.O. Schlager et al / J Endovasc Ther 2005; 12:676-684
6. Comparison to Absolute Peripheral Self-Expanding Stent System - Source: Tests performed by and data on file at Abbott Vascular.
56
• Superior deliverability6
57
Absolute Pro LL
Delivering absolute performance
– Extending our legacy
Peripheral Self-Expanding Stent System
Self-Expanding Stent Systems
Clinically proven1 to treat long SFA lesions2-4
Ordering Information
•Lower binary restenosis rate and sustained clinical benefit with Absolute stent compared with PTA
es
nt
D
Ste
Fracture
Resistance
l
ria
ate
Superb durability
M
nt
Ste
ign
•Quality of life significantly improved after Absolute stenting compared to PTA
80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length
Ref. No. 0.035"
Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Reference Vessel
Diameter
[mm] 1012008-1201012014-120
1012009-1201012015-120
1012010-1201012016-120
1012011-1201012017-120
5
6
7
8
120 6
120 6
120 6
120 6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
1012008-1501012014-150
1012009-1501012015-150
1012010-1501012016-150
1012011-1501012017-150
5
6
7
8
150 6
150 6
150 6
150 6
3.6-4.5
4.3-5.4
5.0-6.3
5.7-7.3
Surface Finish
SFA
•Excellent stent fracture resistance2-5
-Stent material and stent design for outstanding flexibility and vessel conformability
-Advanced stent electro and micro polish for optimal surface finish to enhance stent durability
Uncompromised deliverability1
Triaxial
Technology
•Triaxial technology with:
-Stabilizing sheath to absorb stored energy and minimize friction during deployment
-I-Beam laser-cut hypotube for longitudinal strength, flexibility and pushability during stent delivery
•Ergonomic handle for easy one-handed, controlled deployment
Now available in 120 mm and 150 mm lengths*
120 mm
150 mm
* Artwork shown not to scale.
• Clinically proven to treat long SFA lesions2-4
• Superb durability2-5
• Uncompromised deliverability
1. Source: Data on file at Abbott Vascular.
2. M. Schillinger et al. / NEJM; Vol 354, N18: 1879-1888 /Absolute Vienna Trial
3. M. Schillinger / Circulation 2007; 115:2745-2749
4. S. Sabeti / J Endovasc Ther 2007; 14:431-437
5.O. Schlager et al / J Endovasc Ther 2005; 12:676-684
58
59
Hi-Torque Command
An optimal material fusion for BTK success
Family of .014" Peripheral Guide Wire
Guide Wires
Hybrid workhorse guide wire, specifically designed for
optimal BTK performance
Ordering Information
Dual metal technology, combining the advantages of Stainless Steel and Nitinol,
provides the optimal balance of control and ease of navigation for BTK procedures.
0.014"
Hi-Torque Command
Ref. No.
Wire Length
[cm]
Wire Size
[inch]
Tip Diameter
Tip Style
[inch]
2078172
2078173
190
300
0.014
0.014
0.014
0.014
Tip Stiffness
[g]
Shapeable2.8
Shapeable2.8
Distal Nitinol end for superb
flexibility and tip durability
• Maintains 1-1 torque over the length of the wire
• Handling and control improved by hydrophobic coating
•
Two different support levels:
HT Command, HT Command ES (for extra support)
•Ensures smooth
device compatibility
Tip Load at 10 mm
4.5
4.09
4.0
3.45
3.5
3.0
BTK
Stainless steel body for excellent
torque and support
Tip load (grams)
Transitionless
weld for uniform
support without
stress points
• Two different levels of tip load:
• 2.8 g
• 3.5 g
•Less traumatic and easier to navigate in tortuous
anatomies
• Hydrophilic coating on a radiopaque polymer
cover for improved lubricity, gliding and visibility
2.67
2.77
HT Pilot 150
HT Command
2.5
2.0
1.5
1.0
HT Command Support Curve vs Pilot 150
0.5
0
12
HT Command ES
HT Pilot 200
Source: Data on file at Abbott Vascular.
10
Force value (g)
8
6
4
HT Command ES
HT Command
HT Pilot 150
2
Distance from tip (mm)
240
210
192
168
144
120
96
108
84
72
60
48
36
28
24
20
16
8
12
4
0
0
Nitinol core with
parabolic grind for
excellent torque
and control
Shapeable Nitinol tip
for improved
tip durability
3 cm distal platinum
radiopaque coils
Source: Data on file at Abbott Vascular.
60
61
Hi-Torque Command ES
An optimal material fusion for BTK success
Family of .014" Peripheral Guide Wire
Guide Wires
Hybrid workhorse guide wire, specifically designed for
optimal BTK performance
Ordering Information
Dual metal technology, combining the advantages of Stainless Steel and Nitinol,
provides the optimal balance of control and ease of navigation for BTK procedures.
0.014"
Hi-Torque Command ES
Ref. No.
Wire Length
[cm]
Wire Size
[inch]
Tip Diameter
Tip Style
[inch]
2078174
2078175
190
300
0.014
0.014
0.014
0.014
Tip Stiffness
[g]
Shapeable3.5
Shapeable3.5
Distal Nitinol end for superb
flexibility and tip durability
• Maintains 1-1 torque over the length of the wire
• Handling and control improved by hydrophobic coating
•
Two different support levels:
HT Command, HT Command ES (for extra support)
•Ensures smooth
device compatibility
Tip Load at 10 mm
4.5
4.09
4.0
3.45
3.5
3.0
BTK
Stainless steel body for excellent
torque and support
Tip load (grams)
Transitionless
weld for uniform
support without
stress points
• Two different levels of tip load:
• 2.8 g
• 3.5 g
•Less traumatic and easier to navigate in tortuous
anatomies
• Hydrophilic coating on a radiopaque polymer
cover for improved lubricity, gliding and visibility
2.67
2.77
HT Pilot 150
HT Command
2.5
2.0
1.5
1.0
HT Command Support Curve vs Pilot 150
0.5
0
12
HT Command ES
HT Pilot 200
Source: Data on file at Abbott Vascular.
10
Force value (g)
8
6
4
HT Command ES
HT Command
HT Pilot 150
2
Distance from tip (mm)
240
210
192
168
144
120
96
108
84
72
60
48
36
28
24
20
16
8
12
4
0
0
Nitinol core with
parabolic grind for
excellent torque
and control
Shapeable Nitinol tip
for improved
tip durability
3 cm distal platinum
radiopaque coils
Source: Data on file at Abbott Vascular.
62
63
Hi-Torque Winn
Feel. Cross. Winn.
Family of Chronic Occlusion Guide Wires
Guide Wires
The new standard in guide wires designed
for chronic occlusions
Ordering Information
Hi-Torque Winn family’s unique design offers a selection of tip loads with excellent
tactile feel, maximum torque and pushability for intraluminal crossing of challenging
below-the-knee chronic occlusions.1
0.014"
Hi-Torque Winn 40
Tip Shape
Ref. No.
1012466
1012467
Straight4.8
Straight4.8
Hi-Torque Winn 80
Tip Shape
Ref. No.
Excellent tactile feel
Know where you are
Maximum torque
Be in control
1012468
1012469
• Transitionless DURASTEEL core
taper for maximum torque and
excellent pushability
• Intermediate hydrophilic polymer
sleeve for smooth chronic
occlusion crossing
1012474
1012475
Tip Stiffness
[g]
Straight9.7
Straight9.7
Hi-Torque Winn 200T
Tip Shape
Ref. No.
• Exposed shapeable tip coils for
maximum tactile feedback
• DURASTEEL Core-to-tip for tip
shape retention, control and
precise steering
Tip Stiffness
[g]
Tip Stiffness
[g]
Tip Diameter
[in]
Wire Length
[cm]
0.012 190
0.012 300
Tip Diameter
[in]
Wire Length
[cm]
0.012 190
0.012 300
Tip Diameter
[in]
Wire Length
[cm]
Tapered13.0 0.009 190
Tapered13.0 0.009 300
BTK
Unique tip offerings
Cross confidently
• Breakthrough advancement in the art of chronic occlusion treatment
• 3 tips with varying tip diameter and increasing tip stiffness to cross challenging lesions
Winn 40
Winn 80
Winn 200T
Feel. Cross. Winn.
• Excellent tactile feel
• Maximum torque
• Unique tip offerings
•Ideal for probing
and sliding
•Stiff tip ideal
for drilling
•Extra stiff tapered
tip for penetrating
Hi-Torque Winn is indicated for PTA and PTCA use.
1. Abbott Vascular physician preference testing in 39 BTK cases conducted using Hi-Torque Winn 4/10-6/10.
Illustrations not drawn to scale.
64
65
SPARTACORE 14
Extra support for
lower limb procedures
HI-TORQUE .014" Guide Wire
Guide Wires
Excellent .014" support with superb steerability and
an atraumatic tip
Ordering Information
0.014"
Ref. No.
Floppy -Tip Length
[cm]
Wire Length
[cm]
•High support .014" stainless steel shaft
1005201 1005204 5
10
130*
130*
•5 cm and 10 cm intermediate segments provide excellent torque response
1005202 1005205 5
10
190
190
•Soft, atraumatic shapeable tip
1005203 1005206 5
10
300
300
Engage clinical challenges with support and control
•“Core-to-tip” design for precise steering and tip control
•MICROGLIDE coating provides low friction and superb trackability
Torque devices sold separately in packs of ten (Ref. No. 22215).
*Compatible with DOC guide wire extensions (Ref. No. 22260).
•PTFE coating up to distal 7 cm
•4 cm radiopaque tip coil
•Platinum marker to locate the wire accurately. Measured from the distal tip: 55 cm for the
130 cm length, 90 cm for the 190 cm length, 100 cm for the 300 cm length
BTK
•Available in 130, 190, 300 cm length
Transition length
5 cm
10 cm
66
67
Hi-Torque Connect
The power to connect
Family of .018" Peripheral Guide Wires
Guide Wires
Three distinct wires with:
Ordering Information
• Different support levels to provide options for lesion crossing in straight to tortuous anatomies
• Choice of increasing tip loads and penetration power to maximise crossing in soft to heavily calcified lesions
• Outstanding torque performance and control especially in contralateral approach
Hi-Torque Connect
Support
Hi-Torque Connect
Wire Length
[cm]
Tip Diameter
Tip Shape
[inch]
1012587 145
1012588 195
1012589 300
0.018
0.018
0.018
Hi-Torque Connect Flex
Ref. No.
Tip Diameter
Tip Shape
[inch]
Wire Length
[cm]
Tip Stiffness
[g]
Straight4
Straight4
Straight4
1012590 145
1012591 195
1012592 300
0.018
0.018
0.018
Hi-Torque Connect 250T
Ref. No.
Tip Diameter
Tip Shape
[inch]
Tip Stiffness
[g]
Straight12
Straight12
Straight12
Hi-Torque Connect 250T
Wire Support
Supportive workhorse wire.
Ideal for straight run-off with soft
to moderately calcified occlusions
in focal stenoses.
Hi-Torque Connect
Ref. No.
0.018"
Wire Length
[cm]
1012593 145
1012594 195
1012595 300
0.0125
0.0125
0.0125
Tip Stiffness
[g]
Straight30
Straight30
Straight30
Hi-Torque Connect Flex
Distance from Distal Tip
Penetration Power
BTK
Hi-Torque Connect Flex
250 kg/in2
Trackable workhorse wire.
Increased tip load and flexibility for navigating
tortuous anatomies with acute take-off and
moderately calcified occlusions.
Hi-Torque Connect
52 kg/in2
17 kg/in2
Hi-Torque
Connect
Hi-Torque Connect 250T
Hi-Torque
Connect Flex
Hi-Torque
Connect 250T
Tip Load
Hi-Torque Connect Flex
Specialty CTO wire.
30 g
Specially designed .0125" tapered tip with 30
gram tip load and increased penetration power,
ideal for long, heavy calcifications.
12 g
4g
Hi-Torque
Connect
Hi-Torque
Connect Flex
Hi-Torque
Connect 250T
Hi-Torque Connect 250T
Tests performed by and data on file at Abbott Vascular.
68
69
STEELCORE 18 LT
Extra support for
lower limb procedures
HI-TORQUE .018" Guide Wire
Guide Wires
Providing strong support and flexibility for a
successful crossing
Ordering Information
0.018"
STEELCORE
Tip Shape
Wire Length
Ref. No.
[cm]
One-to-one torque for navigation around vessel bends
•Provides proximal through distal support
• Marker to locate the wire accurately. Measured from the distal tip:
90 cm for the 190 cm length
100 cm for the 300 cm length
1003281* Straight
190
1003282 Straight
300
STEELCORE LT
Tip Shape
Wire Length
Ref. No.
[cm]
• Available in 190 and 300 cm length
1007709* 1007709-J* Straight
J
190
190
• Available in two transition lengths
1007710 1007710-J Straight
J
300
300
Torque devices sold separately and in packs of ten (Ref. No. 22215).
*DOC guide wire extension compatible.
70
60
50
40
BTK
Grams of force at 5 mm
Tip stiffness
30
20
10
0
HI-TORQUE
SteelCore 18
HI-TORQUE
SteelCore 18 LT
Leading competitive
(.018" supportive wire)
Source: Data on file at Abbott Vascular.
HI-TORQUE SteelCore 18 (with 5 cm platinum/nickel tip coil)
Shapeable, flexible tip
Proximal through distal support
Proximal markers assist in determining wire position relative to guide/sheath tip
MICROGLIDE coating provides low friction
and enhanced trackability
Radiopaque platinum tip coil
helps provide accurate positioning
Longer transitions are ideally suited
for angled or acute take-offs
HI-TORQUE SteelCore 18 LT (with 12.5 cm platinum/nickel tip coil)
70
Shapeable, durable tip
71
PTA Catheter
Balloon Dilatation Catheters
Extends your reach:
Taking you further
Ordering Information
90 cm Usable
Shaft Length
Ref. No.
•Catheter and balloon design combine flexibility and strength
to reach more distal lesions without kinking
•Jet coating for smooth delivery
•Thin balloon walls: very low profile
without compromising balloon strength
Reduces procedure time:
Rapid balloon deflation
•Rapid balloon deflation and a full set of
4F compatible BTK sizes to streamline
procedures
•Advanced catheter design provides
a large contrast lumen without flow
restrictions
Largest diameter measured along length of balloon
Maximum Deflated Balloon Profile (mm)
•Streamlined tip and a low profile balloon
designed to enter and cross difficult
lesions
Maximum Deflated Balloon Profile (mm)†
1.2
0.8
Up to
25% lower
profile
1.09
1.18
0.89
0.4
0.0
Armada 14*
Amphirion Deep*
NanoCross*
Time for Full Balloon Deflation from RBP (s)†
100
Deflation Time (s)
Optimizes lesion
entry and crossing:
Successful dilatation
80
77
20
Up to
4 times
faster
Armada 14*
Balloon
Length
[mm]
A1015-020A2015-020
A1020-020A2020-020
A1025-020A2025-020
A1030-020A2030-020
A1040-020A2040-020
1.5
2.0
2.5
3.0
4.0
20
20
20
20
20
A1015-040A2015-040
A1020-040A2020-040
A1025-040A2025-040
A1030-040A2030-040
A1040-040A2040-040
1.5
2.0
2.5
3.0
4.0
40
40
40
40
40
A1020-060A2020-060
A1025-060A2025-060
A1030-060A2030-060
A1040-060A2040-060
2.0
2.5
3.0
4.0
60
60
60
60
A1015-080A2015-080
A1020-080A2020-080
A1025-080A2025-080
A1030-080A2030-080
A1040-080A2040-080
1.5
2.0
2.5
3.0
4.0
80
80
80
80
80
A1015-120A2015-120
A1020-120A2020-120
A1025-120A2025-120
A1030-120A2030-120
A1040-120A2040-120
1.5
2.0
2.5
3.0
4.0
120
120
120
120
120
A1020-200A2020-200
A1025-200A2025-200
A1030-200A2030-200
A1040-200A2040-200
2.0
2.5
3.0
4.0
200
200
200
200
• 4F sheath compatible
• Nominal pressure: 8 atm
41
• RBP: 14 atm
• .014" guide wire compatible
17
0
Balloon Diameter
[mm] • Broad size matrix for a wide
range of lesions
60
40
150 cm Usable
Shaft Length Ref. No.
0.014"
BTK
Armada 14
Defining new possibilities in BTK
Amphirion Deep*
NanoCross*
* Product sizes (all 150 cm catheter length)
Armada 14: 4.0 x 200 mm
Amphirion Deep: 3.5/4.0 x 210 mm
NanoCross: 3.5/4.0 x 210 mm
†Tests perfomed by and data on file at Abbott Vascular.
72
73
Armada 14 XT
Redefining possibilities in BTK therapy
PTA Catheter
Balloon Dilatation Catheters
Ability to perform in challenging situations
Ordering Information
Exceptional push efficiency while maintaining low balloon profile from tip to shaft
•Excellent maneuverability in complex lesions
•Slim Seal Technology1 enables flexible, ultra low profile for smooth delivery and re-cross
Average Push Efficiency
0.180
0.160
145 cm Usable
Shaft Length
Ref. No.
Balloon Diameter
[mm] 0.014"
Balloon
Length
[mm]
F2012-0121.2
F2015-0121.5
F2020-0122.0
12
12
12
F2012-0201.2
F2015-0201.5
F2020-0202.0
20
20
20
0.157
0.140
0.108
0.120
0.100
0.080
0.060
0.051
0.039
0.040
0.020
0.000
Armada 14 XT*
Coyote*
NanoCross*
Amphirion Plus*
Deflated Balloon Profile (in)
BTK
0.0500
Armada 14 XT*
Coyote*
NanoCross*
Amphirion Plus*
0.0450
0.0400
0.0350
0.0300
0.0250
• 4F sheath compatible
0.0200
0.0150
Distal
2/3
1/2
1/4
1 mm Crossing Tip
Shaft Balloon Balloon Balloon Balloon Profile
Entry
Profile Profile Profile Profile Profile
Profile
• Broad size matrix for a wide
range of lesions
• Nominal pressure: 8 atm
2/3
Balloon
Profile
Distal
Shaft
Profile
1/4
Balloon
Profile
Mid Balloon
Profile
1 mm
Balloon
Profile
Tip
Entry
Profile
• RBP: 14 atm
• .014" guide wire compatible
Crossing
Profile
1Slim Seal technology available on 2.0 mm Armada 14 XT.
*Tests performed by and data on file at Abbott Vascular.
Product sizes tested: Armada 14 XT: 2.0 x 20 mm x 145 cm, Coyote: 2.0 x 60 mm x 150 cm,
NanoCross: 2.0 x 20 mm x 150 cm, Amphirion Plus: 2.0 x 14 mm x 150 cm (n=5)
74
75
FOXsv
Mastering the small vessel challenge
Balloon Dilatation Catheters
High pressure balloon
Profile – 4F introducer compatible
High Rated Burst Pressure
– up to 22 bar
Low entry profile
•Eases insertion through tight or occluded lesions
•Enables safer treatment of highly
calcified lesions
Dual lumen shaft design – Rapid inflation/deflation
•Enables to shorten procedure and reduce patient discomfort
Deflation time 80% – Average/Min/Max
Time (s)
25.0
20.0
15.0
10.0
5.0
0.0
Abbott Vascular
FOXsv
Ø 4-120
Abbott Vascular
Submarine Plus
Ø 4-120
Invatec
Amphirion*
Ø 4-120
Invatec
Savvy
Ø 4-100
Cordis
Symmetry
Ø 4-100
Boston Scientific
Source: Data on file at Abbott Vascular.
* This measurement runs out of maximum time record of 20 s.
Excellent balloon rewrap – Minimal deflated balloon profile
•Enables better recrossing of lesions/stents
•Eases insertion and withdrawal through introducer sheaths
12.0
Ordering Information
90 cm Usable
Shaft Length
Ref. No.
135 cm Usable
Shaft Length Ref. No.
150 cm Usable
Shaft Length Ref. No.
Balloon Diameter
[mm] 82158-54-0182157-54-01-
4.0
82168-54-0182167-54-01-
5.0
82144-54-01-
83143-54-012.0
82373-54-01-
83372-54-012.5
82150-54-01-
83149-54-013.0
82160-54-0182159-54-01-
4.0
82170-54-0182169-54-01-
5.0
82180-54-0182179-54-01-
6.0
82146-54-01-
83145-54-012.0
82375-54-01-
83374-54-012.5
82152-54-01-
83151-54-013.0
82162-54-0182161-54-01-
4.0
82172-54-0182171-54-01-
5.0
82148-54-01-
83147-54-012.0
82377-54-01-
83376-54-012.5
82154-54-01-
83153-54-013.0
82164-54-0182163-54-01-
4.0
82174-54-0182173-54-01-
5.0
82184-54-0182183-54-01-
6.0
82198-54-01-
83197-54-012.0
82379-54-01-
83378-54-012.5
82156-54-01-
83155-54-013.0
82166-54-0182165-54-01-
4.0
82176-54-0182175-54-01-
5.0
82186-54-0182185-54-01-
6.0
82946-54-01-
83964-54-012.0
82949-54-01-
83967-54-012.5
82952-54-01-
83970-54-013.0
82955-54-0182973-54-01-
4.0
82958-54-0182976-54-01-
5.0
82961-54-0182979-54-01-
6.0
82947-54-01-
83965-54-012.0
82950-54-01-
83968-54-012.5
82953-54-01-
83971-54-013.0
82956-54-0182974-54-01-
4.0
82959-54-0182977-54-01-
5.0
82962-54-0182980-54-01-
6.0
82948-54-01-
83966-54-012.0
82951-54-01-
83969-54-012.5
82954-54-01-
83972-54-013.0
82957-54-0182975-54-01-
4.0
82960-54-0182978-54-01-
5.0
82963-54-0182981-54-01-
6.0
Balloon Length [mm]
Sheath
Compatibility
[F]
Nominal
Pressure (NP)
[atm]
Rated Burst
Pressure (RBP)
[atm]
15
15
4
4
6
6
20
20
20
20
20
20
20
20
4
4
4
4
4
4
12
12
8
6
6
6
22
22
22
20
20
17
30
30
30
30
30
4
4
4
4
4
12
12
8
6
6
22
22
20
20
20
40
40
40
40
40
40
4
4
4
4
4
4
12
12
8
6
6
6
22
22
20
20
20
17
60
60
60
60
60
60
4
4
4
4
4
4
12
12
8
6
6
6
22
22
20
18
17
17
80
80
80
80
80
80
4
4
4
4
4
4
12
12
8
6
6
6
22
22
20
16
16
15
100
100
100
100
100
100
4
4
4
4
4
4
12
12
8
6
6
6
22
22
20
16
16
15
120
120
120
120
120
120
4
4
4
4
4
4
12
12
8
6
6
6
22
22
20
16
16
15
BTK
PTA Catheter
FOXsv
Ø 4-100
0.018"
Maximum withdrawal force after inflation up to 20 bar – Average/Min/Max
Force (N)
10.0
8.0
6.0
4.0
• Designed for small vessels
2.0
0.0
FOXsv
Ø 4-100
4F introducer
Abbott Vascular
FOXsv
Ø 4-120
4F introducer
Abbott Vascular
Submarine Plus
Ø 4-120
4F introducer
Invatec
Amphirion
Ø 4-120
4F introducer
Invatec
Savvy
Ø 4-100
5F introducer
Cordis
Symmetry
Ø 4-100
5F introducer
Boston Scientific
Source: Data on file at Abbott Vascular.
76
• Optimized hemodynamics
• Conformability
77
XIENCE Prime BTK
Market-leading drug eluting stent platform
Everolimus Eluting Peripheral Stent System
Drug Eluting Stent Systems
Excellent long-term patency of conformable XIENCE platform
Ordering Information
Ref. No.
XIENCE V
Pre-procedure2
XIENCE V
Post-procedure2
Stent
Diameter
[mm] 1012646-282.5
1012646-382.5
1012648-283.0
1012648-383.0
1012649-283.5
1012649-383.5
1012650-284.0
1012650-384.0
1
0.014"
Stent Length [mm] Nominal
RBP Expansion
Pressure
[atm]
[atm]
Max Stent
Diameter
[mm]
28
38
28
38
28
38
28
38
8
8
10
10
10
10
10
10
3.25
3.25
3.75
3.75
4.5
4.5
4.5
4.5
18
18
18
18
18
18
18
18
12 months post-procedure2
Designed for outstanding performance
Clinical advantages of DES
100%
Primary Patency (%)
80%
p=0.0001
60%
XIENCE V
MULTI-LINK VISION
40%
Procedure
6 Months
54.4%
12 Months
Freedom from Target Lesion Revascularization (%)
100%
85.2%
Thin Struts
37% increased freedom from re-interventions5
•For excellent flexibility, conformability
and minimal vessel lumen reduction
91.3%
p=0.005
80%
66.4%
60%
40%
BTK
56% improved primary patency at 12 months 3,4
Controlled Everolimus Drug Release
•Efficacious low-dose potent antiproliferative
drug combined in a polymeric coating
XIENCE V
MULTI-LINK VISION
20%
0%
Procedure
6 Months
12 Months
Low Profile
•Designed to access and
cross difficult lesions
“DES has proven to yield statistically significantly better results than PTA alone or placement of bare
metal stents for the treatment of short BTK lesions, and can therefore be recommended as primary
treatment in these lesion configurations.” 6
Efficacy, Conformability, Deliverability
DESTINY is an Investigator Sponsored Study (ISS). Abbott Vascular does not directly or indirectly promote any off-label use and recommends that the IFU is read thoroughly
before the use of all devices in this study.
1. Q4 2011 publicly reported DES sales; XIENCE platform includes XIENCE V, XIENCE PRIME, and XIENCE nano. Data on file at Abbott Vascular.
2. M. Bosiers, DESTINY, LINC 2011.
3. DESTINY is a multi-center, randomized trial designed to evaluate safety and efficacy of XIENCE V vs. MULTI-LINK VISION in CLI lesions (Rutherford 4,5) on 140 patients.
4. M. Bosiers, DESTINY, LINC 2011.
5. M. Bosiers, D. Scheinert, P. Peeters, G. Torsello, T. Zeller, K. Deloose, J. Tessarek, E. Vinck, L. Schwartz, Randomized comparison of everolimus-eluting versus bare-metal
stents in patients with critical limb ischemia and infrapopliteal arterial occlusive disease. J Vasc Surg 2012 Feb;55(2):390-398.
6. M. Bosiers, K. Deloose, J. Callaert, K. Keirse, J. Verbist, P. Peeters, Drug-eluting stents below the knee. J Cardiovasc Surg 2011 April;52(2):231-4, pg. 234.
78
79
Xpert
The one and only
Stent System
Self-Expanding Stent Systems
The world`s first 4F compatible self-expanding stent
system1, specifically designed for small vessels with
focus on hemodynamics
Ordering Information
Innovation and technology have resulted in a new generation of the Xpert small vessel stent
system, now enabling the treatment of peripheral vessels from diameter 2 mm up to 7 mm.
Each stent diameter was specifically developed to guarantee a Nitinol/vessel wall coverage
of maximum 20%.
Designed for small vessels
Xpert has a homogeneous and diameter independent constant arterial surface coverage
(each stent diameter is specifically designed). The wall coverage is reduced compared to
other NiTi stents.
Radial force
0.8
120 cm Usable
Shaft Length Ref. No.
Stent
Diameter
[mm] Stent Length [mm] Introducer Compatibility
[F]
Reference
Vessel Diameter
[mm]
EX8S2005EX8L2005
EX8S3005EX8L3005
EX8S4005EX8L4005
EX8S6005EX8L6005
5
5
5
5
20
30
40
60
4
4
4
4
3-4
3-4
3-4
3-4
EX8S2006EX8L2006
EX8S3006EX8L3006
EX8S4006EX8L4006
EX8S6006EX8L6006
6
6
6
6
20
30
40
60
4
4
4
5
4-5
4-5
4-5
4-5
EX8S3008EX8L3008 8
EX8S4008EX8L4008 8
EX8S6008EX8L6008 8
30
40
60
5 5-7
5 5-7
5 5-7
90 cm Usable
Shaft Length
Ref. No.
Stent Length [mm] Introducer Compatibility
[F]
EX8S2003EX8L2003 3
EX8S3003EX8L3003 3
EX8S4003EX8L4003 3
20
30
40
4 2-2.5
4 2-2.5
4 2-2.5
EX8S2004EX8L2004
EX8S3004EX8L3004
EX8S4004EX8L4004
EX8S6004EX8L6004
83010-0283011-02
20
30
40
60
80
4
4
4
4
4
135 cm Usable
Shaft Length Ref. No.
Stent
Diameter
[mm] 4
4
4
4
4
Reference
Vessel Diameter
[mm]
2.5-3.5
2.5-3.5
2.5-3.5
2.5-3.5
2.5-3.5
0.6
0.4
BTK
Radial Force [N/cm]
Higher radial force compared to other
.018" guidewire systems. No
compromise in radial force compared
to .035" guidewire systems.
1.0
80 cm Usable
Shaft Length
Ref. No.
0.018"
0.2
0.0
Xpert
Ø3, 4F
Xpert
Ø4, 4F
Xpert
Ø6, 4F
Xpert
Ø8, 5F
Comp D
Ø8, 5F
0.018"
Comp A
Ø8, 6F
0.035"
Source: Data on file at Abbott Vascular.
Conformability
In tortuous anatomies, a good wall apposition ensures, that the vessel lumen is not reduced
and hemodynamics are maintained.
Optimized hemodynamics
The relative wall coverage can be compared to a standard stent in a larger vessel. The
low strut profile also contributes to optimizing the vessel lumen and minimizing the flow
disturbance. This design assures minimal reduction of vessel lumen when placed in a
small vessel.
• Designed for small vessels
• Optimized hemodynamics
Strut profile designed
for large vessels
in a large vessel
Strut profile designed
for large vessels
in a small vessel
Specifically designed
Xpert strut profile
in a small vessel
• Conformability
1. Source: Data on file at Abbott Vascular.
80
81
Xpert Pro
Slim, Tri-Layer Catheter Design
Self-Expanding Stent Systems
Self-Expanding Stent System
Ordering Information
Stent Movement During Deployment
9
Accurate stent deployment
and placement through the
advanced stabilizer coil.
8
Movement (mm)
Less
Accurate
7
6
5
4
3
4.9
2
1
0.1
5.3
3.7
More
Accurate
0
Abbott Vascular Biotronik Astron
Xpert Pro
Pulsar
Invatec Maris
OptiMed
Deep
sinus-Superflex-418
Reach*
3.9F
ngineered for excellent
E
deliverability in complex
cases with the innovative,
slim, intra-laced sheath.
Lowest† catheter system
profile for tight anatomies.
Xpert Pro
4.6F
Astron Pulsar
4.2F
Maris Deep
4.2F
sinus-SuperFlex-418
90 cm
Catheter Length
Ref. No.
135 cm
Catheter Length
Ref. No.
Stent
Diameter
[mm] Stent Length [mm] Sheath Compatibility
[F]
Reference
Vessel Diameter
[mm]
17525-20
17525-30
17525-40
17525-60
17525-80
17525-100
17538-20
17538-30
17538-40
17538-60
17538-80
17538-100
3
3
3
3
3
3
20
30
40
60
80
100
4
4
4
4
4
4
2.0 - 2.5
2.0 - 2.5
2.0 - 2.5
2.0 - 2.5
2.0 - 2.5
2.0 - 2.5
17526-20
17526-30
17526-40
17526-60
17526-80
17526-100
17539-20
17539-30
17539-40
17539-60
17539-80
17539-100
4
4
4
4
4
4
20
30
40
60
80
100
4
4
4
4
4
4
2.5 - 3.5
2.5 - 3.5
2.5 - 3.5
2.5 - 3.5
2.5 - 3.5
2.5 - 3.5
80 cm
Catheter Length
Ref. No.
120 cm
Catheter Length
Ref. No.
Stent
Diameter
[mm] Stent Length [mm] Sheath Compatibility
[F]
Reference
Vessel Diameter
[mm]
17527-20
17527-30
17527-40
17527-60
17527-80
17527-100
17540-20
17540-30
17540-40
17540-60
17540-80
17540-100
5
5
5
5
5
5
20
30
40
60
80
100
4
4
4
4
5
5
3.0 - 4.0
3.0 - 4.0
3.0 - 4.0
3.0 - 4.0
3.0 - 4.0
3.0 - 4.0
17528-20
17528-30
17528-40
17528-60
17528-80
17541-20
17541-30
17541-40
17541-60
17541-80
6
6
6
6
6
20
30
40
60
80
4
4
4
5
5
4.0 - 5.0
4.0 - 5.0
4.0 - 5.0
4.0 - 5.0
4.0 - 5.0
17529-30
17529-40
17529-60
17542-30
17542-40
17542-60
8
8
8
30
40
60
5
5
5
5.0 - 7.0
5.0 - 7.0
5.0 - 7.0
BTK
Precision*
0.018"
†Among competitors listed herein.
Sizes tested:
4 mm x 80 mm: Xpert Pro, Astron Pulsar, Maris Deep
4 mm x 100 mm: sinus-SuperFlex 418
Tests performed by and data on file at Abbott Vascular.
Optimization
Smallest diameter
available (3 mm)
to treat the most
common BTK size.**
Customized Stent Design for Each Vessel Size
Same Strut Thickness
Slim, Tri-Layer Catheter Design
Thinner Strut Thickness
Thin struts for minimal
vessel lumen reduction.
Standard stents use the
same strut thickness for
every vessel size
Xpert Pro is specifically
designed with thinner stent
struts for smaller vessels
* Tests performed by and data on file at Abbott Vascular.
**Lesion reference vessel diameter in XCELL trial was 2.8 ± 0.7. K. Roca-Singh, XCELL Trial Final Data Set, VIVA 2010.
Lesion reference vessel diameter in DESTINY trial was 2.9 ± 0.72 for BMS and 3.0 ± 0.84 for DES. M. Bosiers, BTK Stenting: The DESTINY results, LINC Asia-Pacific 2011.
DESTINY and XCELL are Investigator Sponsored Studies (ISS) – Abbott Vascular does not promote directly or indirectly any out of intended use and recommends that the IFU is read
thoroughly before the use of all devices in these studies.
82
83
StarClose SE
Vascular Closure System
Extravascular evolution
5-6F
Vessel Closure
Clip Closure
The Secure*, Easy, Extravascular solution for vascular
access management
Ordering Information
Ref. No.
Description
Quantity
Circumferential 360˚ mechanical closure.
14679-02
A system includes:
10 systems per box
Secure*
•Device design features for procedural success
• Clip Applier
• 6F Exchange Sheath
• 6F Dilator
• 0.038" 50 cm J-Tip Guide Wire
•Through the sheath deployment - minimized device exchanges
Easy
•Updated device design has improved ergonomics,
stability and a more intuitive user interface
Extravascular
360° closure
•The Clip is designed to close the adventitia and media,
leaving nothing inside the artery
•No disruption of flow or velocity
Actual diameter of the closed Clip: 4 mm
Vessel closure
Actual thickness of the closed Clip: 0.2 mm
• Secure*
• Extravascular
• Easy and quick
• 360˚ closure
*Data on file at Abbott Vascular.
84
85
Perclose ProGlide
Suture-Mediated Closure System
Secure*
•The preferred suture of vascular surgeons1
• Mechanical closure – hemostasis is not clot dependent
• Hemostasis can be challenged and confirmed on the table
Simple
The security of suture
5-8F
Vessel Closure
Suture-Mediated Closure
Ordering Information
Ref. No. Description
Quantity
12673-05
A system includes: 10 systems per box
• 1 Perclose ProGlide 6F Suture-Mediated Closure Device
• 1 Suture Trimmer
• 1 Snared Knot Pusher
•Single operator procedure with QuickCut mechanism
• Pre-tied knot
• Simplified knot delivery
• Numbered deployment sequence
Control
•Immediate re-access
• Vascular access can be maintained throughout deployment
• Ability to pre-close over the wire
• Reduced time to hemostasis, ambulation and discharge
Over-Molded Sheath
Single piece
•Incorporates guide wire exit ramp and white markers for visibility
• Allows smooth transition during device insertion and withdrawal
• Secure*
• Simple
• Control
Vessel closure
Kink resistant
•Single-piece construction reduces potential for kinking during insertion
A History of Innovation
*Data on file at Abbott Vascular.
1. Source: Data on file at Abbott Vascular.
86
87
Prostar XL
Perclose Percutaneous Femoral Artery Closure
Close larger access sites
up to 24F
• Percutaneous vascular closure device
• Integrated pre-dilator to facilitate device placement
Clinical leader for percutaneous large access site closure
Vessel Closure
< 24F
Suture-Mediated Closure
Ordering Information
Ref. No.
Description Quantity
12322-02
A system includes:
5 systems per box
• 1 Prostar XL
• 1 Knot Pusher
Secure* closure
• Uses two braided polyester sutures and four
nitinol needles to provide a secure* close
• Vascular access can be maintained
throughout deployment
• Close access sites up to 24F
• Secure* closure
• Improved outcomes
Improved outcomes
Vessel closure
• Reduces time to hemostasis,
ambulation and discharge
• Improves patient comfort and reduces access site complications
*Data on file at Abbott Vascular.
88
89
Accessories
Accessories
Accessory kits
•Priority packs
Designed to minimize blood loss for a cleaner, safer procedure
Economically bundled combinations of:
1. Indeflator
2. Copilot Or RHV
3. Guide Wire Introducer
4. Torque Device
20/20 priority pack and 20/30 priority pack with RHV (Rotating HemostaticValve)
PTA priority pack 1
Ref. No.
Compatible
Contents
Syringe
[cc/ml] Gauge
[bar/ATM] Diameter [inch/mm]
1003327 20/30 Indeflator Inflation Device 20 30
Copilot Bleedback Control Valve .096/2.44
Guide Wire Introducer Torque Device Guide Wires [inch/mm]
Ref. No.
Compatible
Contents
Syringe
[cc/ml] Gauge
[bar/ATM] Diameter [inch/mm]
22297 1000186 22297-115 1000186-115 20/20 Indeflator Inflation Device 20 20
.096 Rotating Hemostatic Valve .096/2.44
Guide Wire Introducer Torque Device 20/30 Indeflator Inflation Device 20 30
.096 Rotating Hemostatic Valve .096/2.44
Guide Wire Introducer Torque Device 20/20 Indeflator Inflation Device 20 20
.115 Rotating Hemostatic Valve .115/2.92
Guide Wire Introducer Torque Device 20/30 Indeflator Inflation Device 20 30
.115 Rotating Hemostatic Valve .115/2.92
Guide Wire Introducer Torque Device Guide Wires [inch/mm]
.010 – .018/.25 – .45
.010 – .018/.25 – .45
.010 – .018/.25 – .45
.010 – .018/.25 – .45
.010 – .018/.25 – .45
.010 – .018/.25 – .45
.010 – .018/.25 – .45
.010 – .018/.25 – .45
.010 – .018/.25 – .45
.010 – .018/.25 – .45
t
20/20 priority pack and 20/30 priority pack with Copilo
PTA priority pack 2
22296 90
Compatible
Contents
Syringe
[cc/ml] Gauge
[bar/ATM] Diameter [inch/mm]
Indeflator Plus 20 Inflation Device 10 20
.096 Rotating Hemostatic Valve .096/2.44
Guide Wire Introducer Torque Device Guide Wires [inch/mm]
.010 – .018/.25 – .45
.010 – .018/.25 – .45
Compatible
Contents
Syringe
[cc/ml] Gauge
[bar/ATM] Diameter [inch/mm]
1003326 1003327 20/20 Indeflator Inflation Device 20 20
Copilot Bleedback Control Valve .096/2.44
Guide Wire Introducer Torque Device 20/30 Indeflator Inflation Device 20 30
Copilot Bleedback Control Valve .096/2.44
Guide Wire Introducer Torque Device Guide Wires [inch/mm]
accessories
Ref. No.
Ref. No.
.010 – .018/.25 – .45
.010 – .018/.25 – .45
.010 – .018/.25 – .45
.010 – .018/.25 – .45
91
Accessories
Accessories
Hemostatic valves
Ref. No. Description Inner diameter [inch/mm]
1003331
Copilot Bleedback Control Valve
.096/2.44
Ref. No. Description Inner diameter [inch/mm]
23242
23245
.096 Rotating Hemostatic Valve
.115 Rotating Hemostatic Valve
.096/2.44
.115/2.92
Syringe [cc/ml]
Gauge [bar/atM]
24310
1000184
20/20 Indeflator Inflation Device
20/30 Indeflator Inflation Device
20
20
20
30
• Torque device: Provides grip for steering guide wires in the anatomy.
• Guide wire introducer: Engineered to allow easy access of wires through RHVs, while preventing wire tip damage.
Duostat Rotating Hemostatic Valve
Ref. No. Description Inner diameter [inch/mm]
23244
23246
Duostat Rotating Hemostatic Valve
Duostat Rotating Hemostatic Valve.
.096/2.44
.115/2.92
Ref. No. Description Compatible Guide Wires [inch/mm]
22215
Torque Device - 10 Pack
.009 – .018/.22 – .45
Ref. No. Description Compatible Guide Wires [inch/mm]
22290
22231
Guide Wire Introducer - 10 Pack
Funnel Introducer - 10 Pack
.009 – .018/.22 – .45
.009 – .018/.22 – .45
Introducers
Indeflator Plus 20 Inflation Device
Ref. No. Description Syringe [cc/ml]
Gauge [bar/atM]
24301
Indeflator Plus 20 Inflation Device
10
20
Guide Wire Kit with RHV
Ref. No. Description Diameter
Compatible Guide Wires [inch/mm]
22295
Guide Wire Introducer and Torque Device
.096 Rotating Hemostatic Valve.
Guide Wire Introducer and Torque Device
.115 Rotating Hemostatic Valve.
.096/2.44
.009 – .018/.22 – .45
.115/2.92
.009 – .018/.22 – .45
22295-115
Guide Wire Kit with Copilot
Ref. No. Description Diameter
Compatible Guide Wires [inch/mm]
1003330
Guide Wire Introducer and Torque Device
Copilot Bleedback Control Valve.
.096/2.44
.009 – .018/.22 – .45
accessories
• 20/20 Indeflator & 20/30 Indeflator: Ergonomic design for device inflation to a maximum of 20 or 30 atmospheres pressure.
• Plus 20 Indeflator & Plus 30 Indeflator: Standard design for inflation to a maximum of 20 or 30 atmospheres pressure.
Indeflators
Description Torque Devices
Indeflators
92
Ref. No. Guide wire accessories
Rotating Hemostatic Valve
Guide wire accessories & kits
Hemostatic valves
Copilot Bleedback Control Valve
Indeflators
20/20 Indeflator Inflation Device and 20/30 Indeflator Inflation Device
• Copilot bleedback control valve: Designed to minimize blood loss for a cleaner, safer procedure Available in .096”/2.44 mm ID.
• Rotating Hemostatic Valve (RHV): Standard RHV available in .096"/2.44 mm and .115”/2.92 mm sizes.
• Duostat rotating hemostatic valve: Double valve design for multiple device delivery. Available in .096”/2.44 mm and .115”/2.92 mm sizes.
Indeflator Plus 30 Inflation Device
Ref. No. Description Syringe [cc/ml]
Gauge [bar/atM]
1000183
Indeflator Plus 30 Inflation Device
10
30
93
Notes
Notes
94
95
96