Herculink Elite
Transcription
Herculink Elite
RENAL ILIAC SFA BTK Products by indication CAROTID Navigate with a new level of control Embolic Protection System Embolic Protection Navigation Ordering Information Three new .014" BareWires designed specifically for carotid anatomies to ensure navigational success. Emboshield NAV6 Embolic Protection System* Distal Access: A softer BareWire with extra flexibility and torqueability for successful access through tortuous anatomy. Carotid Emboshield NAV 6 0.014" Ref. No. Vessel Diameter Wire Length [cm] Introducer/Guiding Catether Compatibility [F] 22442-19 (small) 2.5-4.8 190 5/6 22443-19 (large) 4.0-7.0 190 5/6 *Emboshield NAV6 Embolic Protection System consists of 2 primary packs: Workhorse: Provides optimal flexibility and support for superb access through most anatomies. Primary Pack Filtration System Content (1) RX Delivery Catheter, (1) Filtration Element, (1) BareWire Filter Delivery Wire (Workhorse, 190 cm), (1) Loading Funnel, (1) Introducer, (1) Torque Device, (1) Syringe with Flushing Tip RX Retrieval Catheter (1) RX Retrieval Catheter, (1) Torque Device, (1) Syringe Flushing Tip BareWire Filter Delivery Wires (.014")** Support: Designed to provide additional support for delivery of filter in challenging arches. Wire Type Ref. No. Wire Length [cm] Distal Access 22444-19 190 Workhorse 22445-19 22445-31 190 315 Support 22446-19 190 **BareWires sold in packs of five. Access .019" Step for filter retrieval Three filter delivery options provide a customized approach to access diverse vascular anatomies. BareWire: Wire access followed by easy filter delivery through tight lesions and challenging anatomies. Fixed: Preloaded wire filter delivery system for one-step advancement through lesion. Excellent Filter Design engineered for enhanced capture and flow Telescope: Alternate advancement of BareWire and delivery system for unparalleled access and support. • Navigation Visibility • Access Radiopaque circumferential frame conveys vessel apposition and deployment status. • Visibility Short Filter Length 120 µm Pore Size with maximum pores for optimal capture efficiency and blood flow 19.0 and 22.5 mm. Fully deployed 2 Fully captured BareWire Advantage: Filter is independent of wire Hydrophilic Coating designed to reduce protein and platelet adhesion 3 Embolic Protection System Embolic Protection Dual strut filter basket Ordering Information 1Stability 2Optimal protection 3Visibility 4Flexibility •Multiple points of contact between filter and vessel for optimal wall apposition •Filter wire torqued independently from filter •Four platinum radiopaque markers on all filter struts Carotid RX Accunet Natural stability 0.014" 190 cm Wire Length Ref. No. 300 cm Wire Length Ref. No. Filter Size [mm] Vessel Diameter [mm] Introducer/ Guiding Catether Compatibility [F] 1011651-45 1011652-45 4.50 3.25-4.00 6/8 1011651-55 1011652-55 5.50 4.00-5.00 6/8 1011651-65 1011652-65 6.50 5.00-6.00 6/8 1011651-75 1011652-75 7.50 6.00-7.00 6/8 •Homogeneous laser-cut holes •Large capture volume while allowing blood flow •Highly flexible nitinol filter basket to conform to vessel tortuosity 2 different recovery catheter choices for challenging anatomies RX Accunet recovery catheter “Shapeable tip design” •Shapeable distal tip deflects catheter from stent struts RX Accunet 2 recovery catheter “Flexible tip design” •Soft, low-profile flexible tip to allow for smooth advancement •Proximal markers for increased ease of use and reduced fluoro time Shapeable recovery catheter tip RX delivery system Ease of use •Balance heavyweight guide wire platform with floppy, pre-shapeable radiopaque tip •RX unsheathing for stability and simplicity •Peel-away delivery sheath allows for controlled deployment Flexible recovery catheter tip • Dual strut filter basket • 2 different recovery catheter choices • RX delivery system 4 5 Rapid Exchange Carotid Stent System Carotid Stenting Xact Carotid Stent Ordering Information Nitinol construction •Straight and tapered configurations •Accurate sizing •Minimal foreshortening •Exceptional crush resistance Unique variable cell size •Increased radial force at lesion •Increased stent coverage at lesion designed to minimise plaque extrusion Carotid Xact Accurate placement with strength where it counts 0.014" Straight Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] ICA Reference Vessel Diameter [mm] CCA Reference Vessel Diameter [mm] XRX02007S XRX02008S XRX02009S XRX02010S 7 8 9 10 20 20 20 20 6 6 6 6 >5.5-6.4 >6.4-7.3 >7.3-8.2 >8.2-9.1 N/A N/A N/A N/A XRX03007S XRX03008S XRX03009S XRX03010S 7 8 9 10 30 30 30 30 6 6 6 6 >5.5-6.4 >6.4-7.3 >7.3-8.2 >8.2-9.1 N/A N/A N/A N/A Tapered Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] ICA Reference Vessel Diameter [mm] CCA Reference Vessel Diameter [mm] XRX03008T XRX03009T XRX03010T 8-6 9-7 10-8 30 30 30 6 6 6 4.8-5.5 >5.5-6.4 >6.4-7.3 6.4-7.3 7.3-8.2 8.2-9.1 XRX04008T XRX04009T XRX04010T 8-6 9-7 10-8 40 40 40 6 6 6 4.8-5.5 >5.5-6.4 >6.4-7.3 6.4-7.3 7.3-8.2 8.2-9.1 •Reduced radial force at healthy vessel segments •Cell design minimises risk of snagging Xact Tapered Xact Straight Freestyle Technology •Stability of system allows accurate placement every time •Low crossing profile (5.7F) •Excellent pushability and trackability •Outstanding radiopacity • Freestyle Technology Single handed operation 6 • Unique variable cell size 7 Carotid Stent System Carotid Stenting The advantages of an innovative design Ordering Information •Highly flexible stents conform to natural vessel anatomies • Truly tapered stents avoid excessive radial force in smaller diameter, internal carotid arteries • Excellent wall apposition ensures sustained long-term plaque coverage • Excellent surface finishing maximizes stent longevity Tapered Straight Straight Ref. No. Stent Diameter [mm] 0.014" Stent Length [mm] Introducer Compatibility [F] ICA Reference Vessel Diameter [mm] CCA Reference Vessel Diameter [mm] 1010126-205 1010127-206 1010128-207 1010129-208 1010130-209 1010131-2010 20 20 20 20 20 20 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.4 5.7-7.3 6.4-8.2 7.1-9.1 N/A N/A N/A N/A N/A N/A 1010126-305 1010127-306 1010128-307 1010129-308 1010130-309 1010131-3010 30 30 30 30 30 30 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.4 5.7-7.3 6.4-8.2 7.1-9.1 N/A N/A N/A N/A N/A N/A 1010126-405 1010127-406 1010128-407 1010129-408 1010130-409 1010131-4010 40 40 40 40 40 40 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.4 5.7-7.3 6.4-8.2 7.1-9.1 N/A N/A N/A N/A N/A N/A Tapered Ref. No. Stent Length [mm] Introducer Compatibility [F] ICA Reference Vessel Diameter [mm] CCA Reference Vessel Diameter [mm] 1010132-306-8 1010133-307-10 30 30 6 6 4.3-5.4 5.0-6.4 5.7-7.3 7.1-9.1 1010132-406-8 1010133-407-10 40 40 6 6 4.3-5.4 5.0-6.4 5.7-7.3 7.1-9.1 Stent Diameter [mm] Carotid RX Acculink Inspired by nature • Highly flexible stent • Low profile • RX Technology 8 9 HI-TORQUE .014" Guide Wire Guide Wires Excellent .014" support with superb steerability and an atraumatic tip Ordering Information 0.014" Ref. No. Floppy -Tip Length [cm] Wire Length [cm] •High support .014" stainless steel shaft 1005201 1005204 5 10 130* 130* •5 cm and 10 cm intermediate segments provide excellent torque response 1005202 1005205 5 10 190 190 •Soft, atraumatic shapeable tip 1005203 1005206 5 10 300 300 Engage clinical challenges with support and control Renal SPARTACORE 14 Extra support for lower limb procedures •“Core-to-tip” design for precise steering and tip control •MICROGLIDE coating provides low friction and superb trackability Torque devices sold separately in packs of ten (Ref. No. 22215). *Compatible with DOC guide wire extensions (Ref. No. 22260). •PTFE coating up to distal 7 cm •4 cm radiopaque tip coil •Platinum marker to locate the wire accurately. Measured from the distal tip: 55 cm for the 130 cm length, 90 cm for the 190 cm length, 100 cm for the 300 cm length •Available in 130, 190, 300 cm length Transition length 5 cm 10 cm 10 11 PTA Balloon Catheter Balloon Dilatation Catheters Low-profile access Ordering Information •.014" guide wire size for easy lesion cross •6F guiding catheter compatibility up to 7.0 mm diameter •Easy contrast injections in a 6F guiding catheter Balloon Ø [mm] Minimum Guide Size [F] Minimum Sheath Size [F] (RX) Rapid exchange •Compatible with shorter 130 cm guide wires 0.014" 80 cm USL 135 cm USL Ref. No. Ref. No. Balloon Balloon Introducer Diameter Length Compatibility [mm] [mm][F] Nominal Rated Burst Pressure (NP) Pressure (RBP) [atm][atm] 1008190-151008189-15 1008192-151008191-15 1008194-151008193-15 1008196-151008195-15 1008198-151008197-15 1008200-151008199-15 1008202-151008201-15 4.0 4.5 5.0 5.5 6.0 6.5 7.0 15 15 15 15 15 15 15 4 4 5 5 5 5 5 8 8 8 8 8 8 8 14 14 14 14 14 14 14 1008190-201008189-20 1008192-201008191-20 1008194-201008193-20 1008196-201008195-20 1008198-201008197-20 1008200-201008199-20 1008202-201008201-20 4.0 4.5 5.0 5.5 6.0 6.5 7.0 20 20 20 20 20 20 20 4 4 5 5 5 5 5 8 8 8 8 8 8 8 14 14 14 14 14 14 14 1008190-301008189-30 1008192-301008191-30 1008194-301008193-30 1008196-301008195-30 1008198-301008197-30 1008200-301008199-30 1008202-301008201-30 4.0 4.5 5.0 5.5 6.0 6.5 7.0 30 30 30 30 30 30 30 4 4 5 5 5 5 5 8 8 8 8 8 8 8 14 14 14 14 14 14 14 1008190-401008189-40 1008192-401008191-40 1008194-401008193-40 1008196-401008195-40 1008198-401008197-40 1008200-401008199-40 1008202-401008201-40 4.0 4.5 5.0 5.5 6.0 6.5 7.0 40 40 40 40 40 40 40 4 4 5 5 5 5 5 8 8 8 8 8 8 8 14 14 14 14 14 14 14 Renal Viatrac 14 Plus Delivering performance through low-profile access •Single operator control •Fast balloon exchanges High-pressure strength •Durable XCELON nylon material offers resilient high pressure capabilities (14 atm RBP) Radiopaque balloon markers •Advanced balloon processing designed for enhanced rewrap and easy withdrawal Deliverable performance .014" maximum guide wire lumen •Flexible distal catheter offers excellent trackability •Tapered support mandrel inside catheter designed to provide shaft pushability and kink resistance • True .014" system •MICROGLIDE coated shaft and balloon for reduced friction • Rapid exchange • High pressure strength XCELON balloon material 12 Soft, tapered tip 13 0.014" Peripheral Stent System Balloon Expandable Stent Systems RX Herculink Elite Ordering Information Building on the proven1 deliverability of RX Herculink, using the advanced metallurgy of cobalt chromium, RX Herculink Elite sets new standards in renal stenting: excellent radiopacity, low profile, high radial strength and superb stent flexibility. 80 cm USL Ref. No. •Grip technology helps ensure excellent stent retention, smooth surface transitions and protection of stent edges •14 atm RBP delivers high-pressure capabilities on a low profile system 135 cm USL Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Comp. [F] Nominal Pressure (NP) [atm] Renal RX Herculink Elite The deliverability of RX Herculink - the performance of CoCr Rated Burst Pressure (RBP) [atm] 1011521-12 1011522-12 4.0 125 1011524-12 1011525-12 4.5 125 1011527-12 1011528-12 5.0 125 1011530-12 1011531-12 5.5 125 1011533-12 1011534-12 6.0 125 1011536-12 1011537-12 6.5 125 1114 1114 1114 1114 1114 1114 1011521-15 1011522-15 4.0 155 1011524-15 1011525-15 4.5 155 1011527-15 1011528-15 5.0 155 1011530-15 1011531-15 5.5 155 1011533-15 1011534-15 6.0 155 1011536-15 1011537-15 6.5 155 1011539-15 1011540-15 7.0 155 1114 1114 1114 1114 1114 1114 1114 1011521-18 1011522-18 4.0 185 1011524-18 1011525-18 4.5 185 1011527-18 1011528-18 5.0 185 1011530-18 1011531-18 5.5 185 1011533-18 1011534-18 6.0 185 1011536-18 1011537-18 6.5 185 1011539-18 1011540-18 7.0 185 1114 1114 1114 1114 1114 1114 1114 XCELON balloon material and Grip technology ensure excellent sizing flexibility and a safe procedure. Stainless steel stent RX Herculink Elite 6F 6F GUIDE 5F 5F SHEATH • Excellent radiopacity Excellent radiopacity Low profile Superb flexibility • Superb flexibility1 • Low profile 1. Data on file at Abbott Vascular. 14 1. Comparison to RX HERCULINK PLUS Biliary Stent System 15 HI-TORQUE .035" Guide Wire Guide Wires Steerability and support in a .035" peripheral guide wire Ordering Information Supportive .035" wire with soft atraumatic tip •Able to facilitate device placement and exchange throughout an entire procedure • Provide the foundation for nearly all your diagnostic and therapeutic needs in the peripheral anatomy 0.035" Ref. No. Tip Shape Wire Length [cm] 1002703 Straight 145 1002703-01 Straight 190 1002703-02 Straight 300 Iliac SUPRA CORE 35 Extra support for lower limb procedures Torque devices sold separately and in packs of ten (Ref. No. 1003279). • Designed to ensure successful clinical performance and successful patient outcomes • Amplatz support with Wholey tip • One-to-one torque response provides exceptional steerability • Radiopaque markers to control wire stability during the procedure • Available in 145, 190 and 300 cm length One-to-one torque response provides exceptional steerability Proximal .025" outer diameter ensures .035" compatible device exchanges 16 MICROGLIDE coating reduces friction, improving wire movement and catheter trackability Exclusively designed 17 cm, tapered .025" core allows support with flexibility for varied device delivery and applications Widow Radiopaque tip allows excellent guide wire placement Shapeable, atraumatic tip 17 Armada 35 A Step Ahead PTA Catheter Balloon Dilatation Catheters Designed to streamline your procedure from start to finish Ordering Information Armada 35 is designed to optimize PTA performance at each stage of your procedure. The combination of finesse and power reduces the need for specialty balloons and keeps you a step ahead in your cases. 80 cm Catheter Length Ref. No. A comprehensive portfolio* with each size range engineered for specific clinical situations. •Small lesion entry profile •Strong pushability •High RBP (up to 28 bar) Workhorse and Pre-Dilatation •Diameters up to 14 mm •Low sheath size compatibility (6F sheath compatible up to 12 mm) •Fast deflation times Large Diameter Frontline performance even in high pressure situations Unmatched pushability with the lowest tip and balloon crossing profiles** to enter and cross lesions without compromising RBP. Push Transmission (%) Lesion Crossing Profile (mm) 53 42 41 1.64 E D A = EverCross B = Admiral Xtreme 1.85 1.86 39 30 ARMADA 35 1.73 1.77 C B 28 F 25 A C = Dorado D = Powerflex P3 1.88 24 22 18 ARMADA 35 1.87 A 17 B 15 F E = Rival F = Ultra-thin Diamond C 15 14 D E = RBP (bar) 135 cm Catheter Length Ref. No. Balloon Diameter [mm] Balloon Min Sheath Length Size [F] [mm] Nominal Pressure [atm] RBP [atm] B1030-020B2030-020 3.0 20 5 B1030-040B2030-040 3.0 40 5 8 28 8 28 B1040-020B2040-020 4.0 B1040-040B2040-040 4.0 B1040-060B2040-060 4.0 B1040-080B2040-080 4.0 B1040-100B2040-100 4.0 B1040-120B2040-120 4.0 20 5 40 5 60 5 80 5 100 5 120 5 8 8 8 8 8 8 25 25 25 20 20 20 B1050-020B2050-020 5.0 B1050-040B2050-040 5.0 B1050-060B2050-060 5.0 B1050-080B2050-080 5.0 B1050-100B2050-100 5.0 B1050-120B2050-120 5.0 20 5 40 5 60 5 80 5 100 5 120 5 8 8 8 8 8 8 22 22 20 18 18 18 B1060-020B2060-020 6.0 B1060-040B2060-040 6.0 B1060-060B2060-060 6.0 B1060-080B2060-080 6.0 B1060-100B2060-100 6.0 B1060-120B2060-120 6.0 20 5 40 5 60 5 80 5 100 5 120 5 6 6 6 6 6 6 20 20 18 16 16 16 B1070-020B2070-020 7.0 B1070-040B2070-040 7.0 B1070-060B2070-060 7.0 B1070-080B2070-080 7.0 B1070-100B2070-100 7.0 B1070-120B2070-120 7.0 20 5 40 5 60 5 80 5 100 6 120 6 6 6 6 6 6 6 15 15 15 14 14 14 B1080-020B2080-020 8.0 B1080-040B2080-040 8.0 B1080-060B2080-060 8.0 B1080-080B2080-080 8.0 20 40 60 80 6 6 6 6 6 6 6 6 15 15 14 13 B1090-020B2090-020 9.0 B1090-040B2090-040 9.0 B1090-060B2090-060 9.0 B1090-080B2090-080 9.0 20 40 60 80 6 6 6 6 6 6 6 6 14 13 12 12 B1100-020B2100-020 10.0 20 B1100-040B2100-040 10.0 40 B1100-060B2100-060 10.0 60 B1100-080B2100-080 10.0 80 6 6 6 6 6 6 6 6 13 12 11 10 B1120-020B2120-020 12.0 20 B1120-040B2120-040 12.0 40 B1120-060B2120-060 12.0 60 B1120-080B2120-080 12.0 80 6 6 6 6 4 4 4 4 10 10 9 9 B1140-020B2140-020 14.0 20 B1140-040B2140-040 14.0 40 B1140-060B2140-060 14.0 60 B1140-080B2140-080 14.0 80 7 7 7 7 4 4 4 4 8 8 7 7 Iliac Engineered to treat the broadest range of lesions 0.035" 6F sheath compatible up to 12 mm * Source: AV Market Intelligence among top competitive devices. **Based on tip and balloon crossing profile measurements and pushability performance bench tests among competitors tested. (Powerflex P3, Ultrathin Diamond, Admiral Xtreme, Dorado, Rival, EverCross) 18 19 Armada 35 LL A Step Ahead PTA Catheter Balloon Dilatation Catheters Designed to streamline your procedure from start to finish Ordering Information Armada 35 LL is designed to optimize PTA performance at each stage of your procedure. The combination of finesse and power reduces the need for specialty balloons and keeps you a step ahead in your cases. 80 cm Catheter Length Ref. No. 0.035" Balloon Diameter [mm] Balloon Min Sheath Length Size [F] [mm] Nominal Pressure [atm] RBP [atm] B1040-150B2040-150 4.0 150 5 B1040-200B2040-200 4.0 200 5 B1040-250B2040-250 4.0 250 5 8 20 8 18 8 18 Engineered to treat the broadest range of lesions B1050-150B2050-150 5.0 150 5 B1050-200B2050-200 5.0 200 5 B1050-250B2050-250 5.0 250 5 8 18 8 18 8 16 A comprehensive portfolio* with each size range engineered for specific clinical situations. B1060-150B2060-150 6.0 150 5 B1060-200B2060-200 6.0 200 6 B1060-250B2060-250 6.0 250 6 6 16 6 14 6 12 B1070-150B2070-150 7.0 150 6 B1070-200B2070-200 7.0 200 6 6 14 6 13 Workhorse and Pre-Dilatation •Small lesion entry profile •Strong pushability Long Length (LL) •Lengths up to 250 mm • Low lesion crossing profiles • Strong pushability • Controlled 3D compliance 6F sheath Frontline performance even in high pressure situations Unmatched pushability with the lowest tip and balloon crossing profiles** to enter and cross lesions without compromising RBP. Push Transmission (%) 41 1.64 ARMADA 35 E D A = EverCross B = Admiral Xtreme 1.73 1.77 1.85 1.86 39 30 C B compatible up to 7 x 200 mm Lesion Crossing Profile (mm) 53 42 Iliac 135 cm Catheter Length Ref. No. 28 F 25 A C = Dorado D = Powerflex P3 1.88 15 14 D E 24 22 18 ARMADA 35 1.87 A 17 B 15 F E = Rival F = Ultra-thin Diamond C = RBP (bar) * Source: AV Market Intelligence among top competitive devices. **Based on tip and balloon crossing profile measurements and pushability performance bench tests among competitors tested. (Powerflex P3, Ultrathin Diamond, Admiral Xtreme, Dorado, Rival, EverCross) 20 21 FOXcross Designed to get you there PTA Catheter Balloon Dilatation Catheters Totally coated balloon system – reduced friction Ordering Information 50 cm Usable Shaft Length Ref. No. •Improved trackability •Improved crossability, especially in calcified long lesions •Reduced pull-back force Effect of jet coating on balloon system Average/Min/Max 16 12 10 8 6 Ø 3-80 Ø 7-120 Ø 12-20 - 58 % 0 - 52 % Ø 3-20 2 - 35 % - 54 % 4 - 43 % Friction force (N) 14 Uncoated Coated Ø 12-60 Balloon size (mm) Source: Data on file at Abbott Vascular. Advanced shaft technology Crescent moon balloon lumen. Increased cross section: rapid deflation Hydrophobic-coated guide wire lumen: excellent trackability Low profile •Compatible 5F sheath up to 7x80 balloon •Tapered tip •Excellent rewrap •High quality manufacturing 22 80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length Ref. No. Balloon Diameter [mm] Balloon Length [mm] Introducer Compatibility [F] Nominal Pressure (NP) [atm] Rated Burst Pressure (RBP) [atm] - 10303-2010312-203 20 5 10 18 - 10304-2010313-204 20 5 10 18 10300-2010305-2010314-205 20 5 9 17 10301-2010306-2010315-206 20 5 8 16 10302-2010307-2010316-207 20 5 8 16 - 10308-20 10317-20 820 6915 - 10309-20 10318-20 920 6914 - 10310-2010319-2010 20 7 7 13 - 10311-2010320-2012 20 7 5 9 - 10344-2010345-2014 20 7 5 8 - 10305-30 10314-30 530 5917 - 10306-30 10315-30 630 5816 - 10307-30 10316-30 730 5816 - 10308-30 10317-30 830 6915 - 10309-30 10318-30 930 6913 - 10310-3010319-3010 30 7 7 13 - 10311-30 - 12307 5 9 - 10303-4010312-403 40 5 10 18 - 10304-4010313-404 40 5 10 18 10300-4010305-4010314-405 40 5 9 17 10301-4010306-4010315-406 40 5 8 16 10302-4010307-4010316-407 40 5 8 16 - 10308-40 10317-40 840 6915 - 10309-40 10318-40 940 6913 - 10310-4010319-4010 40 7 7 13 - 10311-4010320-4012 40 7 5 8 - 10344-4010345-4014 40 7 5 8 - 10304-6010313-604 60 5 10 18 - 10305-60 10314-60 560 5917 - 10306-60 10315-60 660 5815 - 10307-60 10316-60 760 5815 - 10308-60 - 860 6915 - 10309-60 - 960 6913 - 10310-60 - 10607 7 13 - 10311-60 - 12607 5 8 - 10303-8010312-803 80 5 10 17 - 10304-8010313-804 80 5 10 17 - 10305-80 10314-80 580 5917 - 10306-80 10315-80 680 5814 - 10307-80 - 780 5813 - 10308-80 - 880 6913 - 10304-10010313-1004 100 5 10 16 - 10305-100 10314-100 5100 5915 - 10306-100 10315-100 6100 5813 - 10307-100 10316-100 7100 6812 - 10304-12010313-1204 120 5 10 15 - 10305-120 10314-120 5120 5914 - 10306-120 10315-120 6120 5812 - 10307-120 10316-120 7120 6812 Iliac Jet coated balloon, shaft, tip and guide wire lumen 0.035" • Totally coated balloon system • Low profile • Advanced shaft technology 23 FOXplus One for all PTA Catheter Balloon Dilatation Catheters High strength Ordering Information 50 cm Usable Shaft Length Ref. No. •Increases safety in the dilatation of calcified lesions Controlled compliance •Designed to minimize risk of vessel trauma thanks to a predictable diameter at a given pressure Low profile Compatible with a 5F sheath up to the Ø 7 mm balloon Deflated balloon profile (measured in the middle of the balloon) - Average/Min/Max 3.0 (mm) 2.5 2.0 1.5 1.0 0.5 0.0 FOXplus Ø 6-120 Abbott Vascular FOXplus Ø 7-120 Abbott Vascular Sailor Plus Ø 6-120 Invatec Powerflex P3 Ø 7-100 Cordis Opta Pro Ø 7-100 Cordis Opti-Plast XT Ø 7-100 Bard Source: Data on file at Abbott Vascular. Advanced shaft technology Specifically developed dual lumen shaft •Enables reduced inflation/deflation time for an effective and time-saving procedure Deflation time 80% - Average/Min/Max 14.0 Time (s) 12.0 10.0 80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length Ref. No. Balloon Diameter [mm] Balloon Length [mm] Sheath Compatibility [F] Nominal Pressure (NP) [atm] Rated Burst Pressure (RBP) [atm] - AP12003AP220033 20 5 10 18 - AP12004AP220044 20 5 10 18 82360-01 AP12005 AP22005 520 5917 82362-01 AP12006 AP22006 620 5816 82364-01 AP12007 AP22007 720 5816 - AP12008 AP22008 820 6915 - AP12009 AP22009 920 6914 - AP12010AP2201010 20 7 7 13 - AP12012AP2201212 20 7 5 9 - AP13005 AP23005 530 5917 - AP13006 AP23006 630 5816 - AP13007 AP23007 730 5816 - AP13008 AP23008 830 6915 - AP13009 AP23009 930 6913 - AP13010AP2301010 30 7 7 13 - AP13012 - 12307 5 9 - AP14003AP240033 40 5 10 18 - AP14004AP240044 40 5 10 18 82361-01 AP14005 AP24005 540 5917 82363-01 AP14006 AP24006 640 5816 82365-01 AP14007 AP24007 740 5816 - AP14008 AP24008 840 6915 - AP14009 AP24009 940 6913 - AP14010AP2401010 40 7 7 13 - AP14012AP2401212 40 7 5 8 - AP16004AP260044 60 5 10 18 - AP16005 AP26005 560 5917 - AP16006 AP26006 660 5815 - AP16007 AP26007 760 5815 - AP16008 - 860 6915 - AP16009 - 960 6913 - AP16010 - 10607 7 13 - AP16012 - 12607 5 8 - 82906-0182916-013 80 5 10 17 - 82907-0182917-014 80 5 10 17 - AP18005 AP28005 580 5917 - AP18006 AP28006 680 5814 - AP18007 - 780 5813 - AP18008 - 880 6913 - 82908-0182918-014 100 5 10 16 - 82910-01 82920-01 5100 5915 - 82912-01 82922-01 6100 5813 - 82914-01 82924-01 7100 6812 - 82909-0182919-014 120 5 10 15 - 82911-01 82921-01 5120 5914 - 82913-01 82923-01 6120 5812 - 82915-01 82925-01 7120 6812 Iliac Rated Burst Pressure up to 18 bar 0.035" 8.0 6.0 4.0 2.0 • High strength 0.0 FOXplus Ø 6-120 Abbott Vascular FOXplus Ø 7-100 Abbott Vascular Sailor Plus Ø 6-120 Invatec Powerflex P3 Ø 7-100 Cordis Opta Pro Ø 7-100 Cordis Opti-Plast XT Ø 7-100 Bard • Low profile Source: Data on file at Abbott Vascular. • Advanced shaft technology 24 25 Omnilink Elite Setting a new standard in iliac treatment Balloon Expandable Stent Systems Peripheral Stent System SHEATH COMPATIBILITY •Decreased risk of vascular complications 1 Max Profile (mm) 2.50 •Less need to change introducer sheaths for faster procedures and reduced cost1, 2 2.00 1.50 1.00 80 cm Usable Shaft Length Ref. No. Smaller 0.50 •Shorter compression time1, 3 Ordering Information 0.00 Omnilink Elite PALMAZ GENESIS Express Vascular LD Scuba Chromaxx Competitors 135 cm Usable Shaft Length Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Nominal Pressure (NP) [atm] Rated Burst Pressure (RBP) [atm] 11000-12 11007-12 11001-12 11008-12 11002-12 11009-12 11003-12 11010-12 4 5 6 7 126 126 126 126 1114 1114 1116 1116 11000-16 11007-16 11001-16 11008-16 11002-16 11009-16 11003-16 11010-16 4 5 6 7 166 166 166 166 1114 1114 1116 1116 11000-19 11007-19 11001-19 11008-19 11002-19 11009-19 11003-19 11010-19 11004-19 11011-19 11005-19 11012-19 11006-19 11013-19 4 5 6 7 8 9 10 196 196 196 196 196 196 196 1114 1114 1116 1116 1116 1116 1116 11001-29 11008-29 11002-29 11009-29 11003-29 11010-29 11004-29 11011-29 11005-29 11012-29 11006-29 11013-29 5 6 7 8 9 10 296 296 296 296 296 296 1114 1116 1116 1116 1116 1116 11001-39 11008-39 11002-39 11009-39 11003-39 11010-39 11004-39 11011-39 11005-39 11012-39 11006-39 11013-39 5 6 7 8 9 10 396 396 396 396 396 396 1114 1116 1116 1116 1116 1116 11001-59 11008-59 11002-59 11009-59 11003-59 11010-59 11004-59 11011-59 11005-59 11012-59 5 6 7 8 9 596 596 596 596 596 1114 1116 1116 1116 1116 Iliac 3.00 Max Profile of the Distal Stent Delivery System (SDS) Larger 6F sheath compatible across all sizes 0.035" Source: Data on file at Abbott Vascular. Delivery Force 500 More Difficult Excellent deliverability •Dual-lumen catheterprovides strong push •Dual-layer balloon withexcellent stent retention 400 350 DELIVERABILITY •Low-profile tip Maximum Track Force (g) 450 300 250 200 150 100 0 Easier 50 Omnilink Elite PALMAZ GENESIS Express Vascular LD Scuba Chromaxx Competitors Source: Data on file at Abbott Vascular. 200 Expanded Stent Flexibility Less Flexibility without compromising strength 180 •High RBP •No compromise in strength or radiopacity FLEXIBILITY 120 100 80 Large crescent shape contrast lumen 60 40 20 0 More •Proven4 flexible stent design Stiffness (gf) 140 •Thin CoCr stent struts Dual-lumen catheter shaft Separate guide wire lumen 160 Omnilink Elite PALMAZ GENESIS Express Vascular LD Scuba CoCr material Dual-layer balloon Chromaxx Five-fold wrap balloon Competitors Source: Data on file at Abbott Vascular. 1. M etz D, Meyer F, Touati C et al. Am Heart J 1997;134(1):131-137. 2. T alley JD, Mauldin PD, Becker ER. J Interv Cardiol 1995;8(4):345-353. 3. B üchler JR, Ribeiro EE, Falcão JL et al. J Interven Cardiol 2008;21(1):50-55 4. Source: Data on file at Abbott Vascular. MULTI-LINK stent design • Excellent radiopacity • Superb flexibility Soft tip • Low profile 26 27 Absolute Pro Delivering absolute performance Peripheral Self-Expanding Stent System Self-Expanding Stent Systems Smoother stent with lower fracture rate1 Ordering Information •Stent flexibility •Stent fracture resistance in both bending and axial modes A B A. 8.0x60 mm Absolute – Abbott Vascular B. 8.0x60 mm Competitor Superior deliverability1 The innovative triaxial technology with I-BEAM laser-cut hypotube ensures: •Improved kink resistance •Accurate stent placement and deployment 80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Reference Vessel Diameter [mm] 1011914-0201011920-020 1011915-0201011921-020 1011916-0201011922-020 1011917-0201011923-020 1011918-0201011924-020 1011919-0201011925-020 5 6 7 8 9 10 20 20 20 20 20 20 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 1011914-0301011920-030 1011915-0301011921-030 1011916-0301011922-030 1011917-0301011923-030 1011918-0301011924-030 1011919-0301011925-030 5 6 7 8 9 10 30 30 30 30 30 30 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 1011914-0401011920-040 1011915-0401011921-040 1011916-0401011922-040 1011917-0401011923-040 1011918-0401011924-040 1011919-0401011925-040 5 6 7 8 9 10 40 40 40 40 40 40 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 1011914-0601011920-060 1011915-0601011921-060 1011916-0601011922-060 1011917-0601011923-060 1011918-0601011924-060 1011919-0601011925-060 5 6 7 8 9 10 60 60 60 60 60 60 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 1011914-0801011920-080 1011915-0801011921-080 1011916-0801011922-080 1011917-0801011923-080 1011918-0801011924-080 1011919-0801011925-080 5 6 7 8 9 10 80 80 80 80 80 80 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 1011914-1001011920-100 1011915-1001011921-100 1011916-1001011922-100 1011917-1001011923-100 1011918-1001011924-100 1011919-1001011925-100 5 6 7 8 9 10 100 6 100 6 100 6 100 6 100 6 100 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 Iliac The Absolute stent design, material and surface finish assure: 0.035" I-BEAM laser-cut hypotube Stabilizing Sheath Retracting Sheath • Proven1 clinical outcomes2-4 • Fracture resistance2-5 1. Source: Data on file at Abbott Vascular. 2. M. Schillinger et al. / NEJM; Vol 354, N18: 1879-1888 /Absolute Vienna Trial 3. M. Schillinger / Circulation 2007; 115:2745-2749 4. S. Sabeti / J Endovasc Ther 2007; 14:431-437 5.O. Schlager et al / J Endovasc Ther 2005; 12:676-684 6. Comparison to Absolute Peripheral Self-Expanding Stent System - Source: Tests performed by and data on file at Abbott Vascular. 28 • Superior deliverability6 29 Absolute Pro LL Delivering absolute performance – Extending our legacy Peripheral Self-Expanding Stent System Self-Expanding Stent Systems Clinically proven1 to treat long SFA lesions2-4 Ordering Information es nt D Ste Fracture Resistance l ria ate Superb durability M nt Ste ign •Quality of life significantly improved after Absolute stenting compared to PTA 80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Reference Vessel Diameter [mm] 1012008-1201012014-120 1012009-1201012015-120 1012010-1201012016-120 1012011-1201012017-120 5 6 7 8 120 6 120 6 120 6 120 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 1012008-1501012014-150 1012009-1501012015-150 1012010-1501012016-150 1012011-1501012017-150 5 6 7 8 150 6 150 6 150 6 150 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 Iliac •Lower binary restenosis rate and sustained clinical benefit with Absolute stent compared with PTA 0.035" Surface Finish •Excellent stent fracture resistance2-5 -Stent material and stent design for outstanding flexibility and vessel conformability -Advanced stent electro and micro polish for optimal surface finish to enhance stent durability Uncompromised deliverability1 Triaxial Technology •Triaxial technology with: -Stabilizing sheath to absorb stored energy and minimize friction during deployment -I-Beam laser-cut hypotube for longitudinal strength, flexibility and pushability during stent delivery •Ergonomic handle for easy one-handed, controlled deployment Now available in 120 mm and 150 mm lengths* 120 mm 150 mm * Artwork shown not to scale. • Clinically proven to treat long SFA lesions2-4 • Superb durability2-5 • Uncompromised deliverability 1. Source: Data on file at Abbott Vascular. 2. M. Schillinger et al. / NEJM; Vol 354, N18: 1879-1888 /Absolute Vienna Trial 3. M. Schillinger / Circulation 2007; 115:2745-2749 4. S. Sabeti / J Endovasc Ther 2007; 14:431-437 5.O. Schlager et al / J Endovasc Ther 2005; 12:676-684 30 31 Hi-Torque Command ES An optimal material fusion for BTK success Family of .014" Peripheral Guide Wire Guide Wires Hybrid workhorse guide wire, specifically designed for optimal BTK performance Ordering Information Dual metal technology, combining the advantages of Stainless Steel and Nitinol, provides the optimal balance of control and ease of navigation for BTK procedures. 0.014" Hi-Torque Command Ref. No. Wire Length [cm] Wire Size [inch] Tip Diameter Tip Style [inch] 2078174 2078175 190 300 0.014 0.014 0.014 0.014 Tip Stiffness [g] Shapeable3.5 Shapeable3.5 Distal Nitinol end for superb flexibility and tip durability Stainless steel body for excellent torque and support • Maintains 1-1 torque over the length of the wire • Handling and control improved by hydrophobic coating • Two different support levels: HT Command, HT Command ES (for extra support) •Ensures smooth device compatibility SFA Tip Load at 10 mm 4.5 4.09 4.0 3.45 3.5 Tip load (grams) Transitionless weld for uniform support without stress points • Two different levels of tip load: • 2.8 g • 3.5 g •Less traumatic and easier to navigate in tortuous anatomies • Hydrophilic coating on a radiopaque polymer cover for improved lubricity, gliding and visibility 3.0 2.67 2.77 HT Pilot 150 HT Command 2.5 2.0 1.5 1.0 HT Command Support Curve vs Pilot 150 0.5 0 12 HT Command ES HT Pilot 200 Source: Data on file at Abbott Vascular. 10 Force value (g) 8 6 4 HT Command ES HT Command HT Pilot 150 2 Distance from tip (mm) 240 210 192 168 144 120 96 108 84 72 60 48 36 28 24 20 16 8 12 4 0 0 Nitinol core with parabolic grind for excellent torque and control Shapeable Nitinol tip for improved tip durability 3 cm distal platinum radiopaque coils Source: Data on file at Abbott Vascular. 32 33 Hi-Torque Connect The power to connect Family of .018" Peripheral Guide Wires Guide Wires Three distinct wires with: Ordering Information • Different support levels to provide options for lesion crossing in straight to tortuous anatomies • Choice of increasing tip loads and penetration power to maximise crossing in soft to heavily calcified lesions • Outstanding torque performance and control especially in contralateral approach Support Hi-Torque Connect Tip Diameter Tip Shape [inch] 1012587 145 1012588 195 1012589 300 0.018 0.018 0.018 Hi-Torque Connect Flex Ref. No. Tip Diameter Tip Shape [inch] Wire Length [cm] Tip Stiffness [g] Straight4 Straight4 Straight4 1012590 145 1012591 195 1012592 300 0.018 0.018 0.018 Hi-Torque Connect 250T Ref. No. Tip Diameter Tip Shape [inch] Tip Stiffness [g] Straight12 Straight12 Straight12 Hi-Torque Connect 250T Wire Support Supportive workhorse wire. Ideal for straight run-off with soft to moderately calcified occlusions in focal stenoses. Wire Length [cm] Wire Length [cm] 1012593 145 1012594 195 1012595 300 0.0125 0.0125 0.0125 Tip Stiffness [g] Straight30 Straight30 Straight30 SFA Hi-Torque Connect Hi-Torque Connect Ref. No. 0.018" Hi-Torque Connect Flex Distance from Distal Tip Hi-Torque Connect Flex Penetration Power 250 kg/in2 Trackable workhorse wire. Increased tip load and flexibility for navigating tortuous anatomies with acute take-off and moderately calcified occlusions. Hi-Torque Connect 52 kg/in2 17 kg/in2 Hi-Torque Connect Hi-Torque Connect 250T Hi-Torque Connect Flex Hi-Torque Connect 250T Tip Load Hi-Torque Connect Flex Specialty CTO wire. 30 g Specially designed .0125" tapered tip with 30 gram tip load and increased penetration power, ideal for long, heavy calcifications. 12 g 4g Hi-Torque Connect Hi-Torque Connect Flex Hi-Torque Connect 250T Hi-Torque Connect 250T Tests performed by and data on file at Abbott Vascular. 34 35 Hi-Torque Winn Feel. Cross. Winn. Family of Chronic Occlusion Guide Wires Guide Wires The new standard in guide wires designed for chronic occlusions Ordering Information Hi-Torque Winn family’s unique design offers a selection of tip loads with excellent tactile feel, maximum torque and pushability for intraluminal crossing of challenging below-the-knee chronic occlusions.1 0.014" Hi-Torque Winn 40 Tip Shape Ref. No. 1012466 1012467 Straight4.8 Straight4.8 Hi-Torque Winn 80 Tip Shape Ref. No. Excellent tactile feel Know where you are Maximum torque Be in control 1012468 1012469 1012474 1012475 Tip Stiffness [g] Tip Diameter [in] Wire Length [cm] 0.012 190 0.012 300 Tip Diameter [in] Wire Length [cm] 0.012 190 0.012 300 Tip Diameter [in] Wire Length [cm] Tapered13.0 0.009 190 Tapered13.0 0.009 300 SFA • Transitionless DURASTEEL core taper for maximum torque and excellent pushability • Intermediate hydrophilic polymer sleeve for smooth chronic occlusion crossing Tip Stiffness [g] Straight9.7 Straight9.7 Hi-Torque Winn 200T Tip Shape Ref. No. • Exposed shapeable tip coils for maximum tactile feedback • DURASTEEL Core-to-tip for tip shape retention, control and precise steering Tip Stiffness [g] Unique tip offerings Cross confidently • Breakthrough advancement in the art of chronic occlusion treatment • 3 tips with varying tip diameter and increasing tip stiffness to cross challenging lesions Winn 40 Winn 80 Winn 200T Feel. Cross. Winn. • Excellent tactile feel • Maximum torque • Unique tip offerings •Ideal for probing and sliding •Stiff tip ideal for drilling •Extra stiff tapered tip for penetrating Hi-Torque Winn is indicated for PTA and PTCA use. 1. Abbott Vascular physician preference testing in 39 BTK cases conducted using Hi-Torque Winn 4/10-6/10. Illustrations not drawn to scale. 36 37 STEELCORE 18 LT Extra support for lower limb procedures HI-TORQUE .018" Guide Wire Guide Wires Providing strong support and flexibility for a successful crossing Ordering Information 0.018" STEELCORE Tip Shape Wire Length Ref. No. [cm] One-to-one torque for navigation around vessel bends •Provides proximal through distal support • Marker to locate the wire accurately. Measured from the distal tip: 90 cm for the 190 cm length 100 cm for the 300 cm length 1003281* Straight 190 1003282 Straight 300 STEELCORE LT Tip Shape Wire Length Ref. No. [cm] • Available in 190 and 300 cm length 1007709* 1007709-J* Straight J 190 190 • Available in two transition lengths 1007710 1007710-J Straight J 300 300 Torque devices sold separately and in packs of ten (Ref. No. 22215). *DOC guide wire extension compatible. Grams of force at 5 mm SFA Tip stiffness 70 60 50 40 30 20 10 0 HI-TORQUE SteelCore 18 HI-TORQUE SteelCore 18 LT Leading competitive (.018" supportive wire) Source: Data on file at Abbott Vascular. HI-TORQUE SteelCore 18 (with 5 cm platinum/nickel tip coil) Shapeable, flexible tip Proximal through distal support Proximal markers assist in determining wire position relative to guide/sheath tip MICROGLIDE coating provides low friction and enhanced trackability Radiopaque platinum tip coil helps provide accurate positioning Longer transitions are ideally suited for angled or acute take-offs HI-TORQUE SteelCore 18 LT (with 12.5 cm platinum/nickel tip coil) 38 Shapeable, durable tip 39 SUPRA CORE 35 Extra support for lower limb procedures HI-TORQUE .035" Guide Wire Guide Wires Steerability and support in a .035" peripheral guide wire Ordering Information Supportive .035" wire with soft atraumatic tip •Able to facilitate device placement and exchange throughout an entire procedure • Provide the foundation for nearly all your diagnostic and therapeutic needs in the peripheral anatomy 0.035" Ref. No. Tip Shape Wire Length [cm] 1002703 Straight 145 1002703-01 Straight 190 1002703-02 Straight 300 Torque devices sold separately and in packs of ten (Ref. No. 1003279). • Designed to ensure successful clinical performance and successful patient outcomes • Amplatz support with Wholey tip • One-to-one torque response provides exceptional steerability SFA • Radiopaque markers to control wire stability during the procedure • Available in 145, 190 and 300 cm length One-to-one torque response provides exceptional steerability Proximal .025" outer diameter ensures .035" compatible device exchanges 40 MICROGLIDE coating reduces friction, improving wire movement and catheter trackability Exclusively designed 17 cm, tapered .025" core allows support with flexibility for varied device delivery and applications Widow Radiopaque tip allows excellent guide wire placement Shapeable, atraumatic tip 41 Armada 35 A Step Ahead PTA Catheter Balloon Dilatation Catheters Designed to streamline your procedure from start to finish Ordering Information Armada 35 is designed to optimize PTA performance at each stage of your procedure. The combination of finesse and power reduces the need for specialty balloons and keeps you a step ahead in your cases. 80 cm Catheter Length Ref. No. A comprehensive portfolio* with each size range engineered for specific clinical situations. •Small lesion entry profile •Strong pushability •High RBP (up to 28 bar) Workhorse and Pre-Dilatation •Diameters up to 14 mm •Low sheath size compatibility (6F sheath compatible up to 12 mm) •Fast deflation times Large Diameter Frontline performance even in high pressure situations Unmatched pushability with the lowest tip and balloon crossing profiles** to enter and cross lesions without compromising RBP. Push Transmission (%) Lesion Crossing Profile (mm) 53 42 41 1.64 E D A = EverCross B = Admiral Xtreme 1.85 1.86 39 30 ARMADA 35 1.73 1.77 C B 28 F 25 A C = Dorado D = Powerflex P3 1.88 24 22 18 ARMADA 35 1.87 A 17 B 15 F E = Rival F = Ultra-thin Diamond C 15 14 D E = RBP (bar) 135 cm Catheter Length Ref. No. Balloon Diameter [mm] Balloon Min Sheath Length Size [F] [mm] Nominal Pressure [atm] RBP [atm] B1030-020B2030-020 3.0 20 5 B1030-040B2030-040 3.0 40 5 8 28 8 28 B1040-020B2040-020 4.0 B1040-040B2040-040 4.0 B1040-060B2040-060 4.0 B1040-080B2040-080 4.0 B1040-100B2040-100 4.0 B1040-120B2040-120 4.0 20 5 40 5 60 5 80 5 100 5 120 5 8 8 8 8 8 8 25 25 25 20 20 20 B1050-020B2050-020 5.0 B1050-040B2050-040 5.0 B1050-060B2050-060 5.0 B1050-080B2050-080 5.0 B1050-100B2050-100 5.0 B1050-120B2050-120 5.0 20 5 40 5 60 5 80 5 100 5 120 5 8 8 8 8 8 8 22 22 20 18 18 18 B1060-020B2060-020 6.0 B1060-040B2060-040 6.0 B1060-060B2060-060 6.0 B1060-080B2060-080 6.0 B1060-100B2060-100 6.0 B1060-120B2060-120 6.0 20 5 40 5 60 5 80 5 100 5 120 5 6 6 6 6 6 6 20 20 18 16 16 16 B1070-020B2070-020 7.0 B1070-040B2070-040 7.0 B1070-060B2070-060 7.0 B1070-080B2070-080 7.0 B1070-100B2070-100 7.0 B1070-120B2070-120 7.0 20 5 40 5 60 5 80 5 100 6 120 6 6 6 6 6 6 6 15 15 15 14 14 14 B1080-020B2080-020 8.0 B1080-040B2080-040 8.0 B1080-060B2080-060 8.0 B1080-080B2080-080 8.0 20 40 60 80 6 6 6 6 6 6 6 6 15 15 14 13 B1090-020B2090-020 9.0 B1090-040B2090-040 9.0 B1090-060B2090-060 9.0 B1090-080B2090-080 9.0 20 40 60 80 6 6 6 6 6 6 6 6 14 13 12 12 B1100-020B2100-020 10.0 20 B1100-040B2100-040 10.0 40 B1100-060B2100-060 10.0 60 B1100-080B2100-080 10.0 80 6 6 6 6 6 6 6 6 13 12 11 10 B1120-020B2120-020 12.0 20 B1120-040B2120-040 12.0 40 B1120-060B2120-060 12.0 60 B1120-080B2120-080 12.0 80 6 6 6 6 4 4 4 4 10 10 9 9 B1140-020B2140-020 14.0 20 B1140-040B2140-040 14.0 40 B1140-060B2140-060 14.0 60 B1140-080B2140-080 14.0 80 7 7 7 7 4 4 4 4 8 8 7 7 SFA Engineered to treat the broadest range of lesions 0.035" 6F sheath compatible up to 12 mm * Source: AV Market Intelligence among top competitive devices. **Based on tip and balloon crossing profile measurements and pushability performance bench tests among competitors tested. (Powerflex P3, Ultrathin Diamond, Admiral Xtreme, Dorado, Rival, EverCross) 42 43 Armada 35 LL A Step Ahead PTA Catheter Balloon Dilatation Catheters Designed to streamline your procedure from start to finish Ordering Information Armada 35 LL is designed to optimize PTA performance at each stage of your procedure. The combination of finesse and power reduces the need for specialty balloons and keeps you a step ahead in your cases. 80 cm Catheter Length Ref. No. 0.035" 135 cm Catheter Length Ref. No. Balloon Diameter [mm] Balloon Min Sheath Length Size [F] [mm] Nominal Pressure [atm] RBP [atm] 8 20 8 18 8 18 Engineered to treat the broadest range of lesions B1050-150B2050-150 5.0 150 5 B1050-200B2050-200 5.0 200 5 B1050-250B2050-250 5.0 250 5 8 18 8 18 8 16 A comprehensive portfolio* with each size range engineered for specific clinical situations. B1060-150B2060-150 6.0 150 5 B1060-200B2060-200 6.0 200 6 B1060-250B2060-250 6.0 250 6 6 16 6 14 6 12 B1070-150B2070-150 7.0 150 6 B1070-200B2070-200 7.0 200 6 6 14 6 13 Workhorse and Pre-Dilatation •Small lesion entry profile •Strong pushability Long Length (LL) •Lengths up to 250 mm • Low lesion crossing profiles • Strong pushability • Controlled 3D compliance SFA B1040-150B2040-150 4.0 150 5 B1040-200B2040-200 4.0 200 5 B1040-250B2040-250 4.0 250 5 6F sheath Frontline performance even in high pressure situations Unmatched pushability with the lowest tip and balloon crossing profiles** to enter and cross lesions without compromising RBP. Push Transmission (%) Lesion Crossing Profile (mm) 53 42 41 1.64 ARMADA 35 E D A = EverCross B = Admiral Xtreme 1.73 1.77 1.85 1.86 39 30 C B compatible up to 7 x 200 mm 28 F 25 A C = Dorado D = Powerflex P3 1.88 15 14 D E 24 22 18 ARMADA 35 1.87 A 17 B 15 F E = Rival F = Ultra-thin Diamond C = RBP (bar) * Source: AV Market Intelligence among top competitive devices. **Based on tip and balloon crossing profile measurements and pushability performance bench tests among competitors tested. (Powerflex P3, Ultrathin Diamond, Admiral Xtreme, Dorado, Rival, EverCross) 44 45 FOXsv Mastering the small vessel challenge Balloon Dilatation Catheters High pressure balloon Profile – 4F introducer compatible High Rated Burst Pressure – up to 22 bar Low entry profile •Eases insertion through tight or occluded lesions •Enables safer treatment of highly calcified lesions Dual lumen shaft design – Rapid inflation/deflation •Enables to shorten procedure and reduce patient discomfort Deflation time 80% – Average/Min/Max Time (s) 25.0 20.0 15.0 10.0 5.0 0.0 Abbott Vascular FOXsv Ø 4-120 Abbott Vascular Submarine Plus Ø 4-120 Invatec Amphirion* Ø 4-120 Invatec Savvy Ø 4-100 Cordis Symmetry Ø 4-100 Boston Scientific Source: Data on file at Abbott Vascular. * This measurement runs out of maximum time record of 20 s. Excellent balloon rewrap – Minimal deflated balloon profile •Enables better recrossing of lesions/stents •Eases insertion and withdrawal through introducer sheaths 12.0 Ordering Information 90 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length Ref. No. 150 cm Usable Shaft Length Ref. No. Balloon Diameter [mm] 82158-54-0182157-54-01- 4.0 82168-54-0182167-54-01- 5.0 82144-54-01- 83143-54-012.0 82373-54-01- 83372-54-012.5 82150-54-01- 83149-54-013.0 82160-54-0182159-54-01- 4.0 82170-54-0182169-54-01- 5.0 82180-54-0182179-54-01- 6.0 82146-54-01- 83145-54-012.0 82375-54-01- 83374-54-012.5 82152-54-01- 83151-54-013.0 82162-54-0182161-54-01- 4.0 82172-54-0182171-54-01- 5.0 82148-54-01- 83147-54-012.0 82377-54-01- 83376-54-012.5 82154-54-01- 83153-54-013.0 82164-54-0182163-54-01- 4.0 82174-54-0182173-54-01- 5.0 82184-54-0182183-54-01- 6.0 82198-54-01- 83197-54-012.0 82379-54-01- 83378-54-012.5 82156-54-01- 83155-54-013.0 82166-54-0182165-54-01- 4.0 82176-54-0182175-54-01- 5.0 82186-54-0182185-54-01- 6.0 82946-54-01- 83964-54-012.0 82949-54-01- 83967-54-012.5 82952-54-01- 83970-54-013.0 82955-54-0182973-54-01- 4.0 82958-54-0182976-54-01- 5.0 82961-54-0182979-54-01- 6.0 82947-54-01- 83965-54-012.0 82950-54-01- 83968-54-012.5 82953-54-01- 83971-54-013.0 82956-54-0182974-54-01- 4.0 82959-54-0182977-54-01- 5.0 82962-54-0182980-54-01- 6.0 82948-54-01- 83966-54-012.0 82951-54-01- 83969-54-012.5 82954-54-01- 83972-54-013.0 82957-54-0182975-54-01- 4.0 82960-54-0182978-54-01- 5.0 82963-54-0182981-54-01- 6.0 Balloon Length [mm] Sheath Compatibility [F] Nominal Pressure (NP) [atm] Rated Burst Pressure (RBP) [atm] 15 15 4 4 6 6 20 20 20 20 20 20 20 20 4 4 4 4 4 4 12 12 8 6 6 6 22 22 22 20 20 17 30 30 30 30 30 4 4 4 4 4 12 12 8 6 6 22 22 20 20 20 40 40 40 40 40 40 4 4 4 4 4 4 12 12 8 6 6 6 22 22 20 20 20 17 60 60 60 60 60 60 4 4 4 4 4 4 12 12 8 6 6 6 22 22 20 18 17 17 80 80 80 80 80 80 4 4 4 4 4 4 12 12 8 6 6 6 22 22 20 16 16 15 100 100 100 100 100 100 4 4 4 4 4 4 12 12 8 6 6 6 22 22 20 16 16 15 120 120 120 120 120 120 4 4 4 4 4 4 12 12 8 6 6 6 22 22 20 16 16 15 SFA PTA Catheter FOXsv Ø 4-100 0.018" Maximum withdrawal force after inflation up to 20 bar – Average/Min/Max Force (N) 10.0 8.0 6.0 4.0 • Designed for small vessels 2.0 0.0 FOXsv Ø 4-100 4F introducer Abbott Vascular FOXsv Ø 4-120 4F introducer Abbott Vascular Submarine Plus Ø 4-120 4F introducer Invatec Amphirion Ø 4-120 4F introducer Invatec Savvy Ø 4-100 5F introducer Cordis Symmetry Ø 4-100 5F introducer Boston Scientific Source: Data on file at Abbott Vascular. 46 • Optimized hemodynamics • Conformability 47 FOXcross Designed to get you there PTA Catheter Balloon Dilatation Catheters Totally coated balloon system – reduced friction Ordering Information 50 cm Usable Shaft Length Ref. No. •Improved trackability •Improved crossability, especially in calcified long lesions •Reduced pull-back force Effect of jet coating on balloon system Average/Min/Max 16 12 10 8 6 Ø 3-80 Ø 7-120 Ø 12-20 - 58 % 0 - 52 % Ø 3-20 2 - 35 % - 54 % 4 - 43 % Friction force (N) 14 Uncoated Coated Ø 12-60 Balloon size (mm) Source: Data on file at Abbott Vascular. Advanced shaft technology Crescent moon balloon lumen. Increased cross section: rapid deflation Hydrophobic-coated guide wire lumen: excellent trackability Low profile •Compatible 5F sheath up to 7x80 balloon •Tapered tip •Excellent rewrap •High quality manufacturing 48 80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length Ref. No. Balloon Diameter [mm] Balloon Length [mm] Introducer Compatibility [F] Nominal Pressure (NP) [atm] Rated Burst Pressure (RBP) [atm] - 10303-2010312-203 20 5 10 18 - 10304-2010313-204 20 5 10 18 10300-2010305-2010314-205 20 5 9 17 10301-2010306-2010315-206 20 5 8 16 10302-2010307-2010316-207 20 5 8 16 - 10308-20 10317-20 820 6915 - 10309-20 10318-20 920 6914 - 10310-2010319-2010 20 7 7 13 - 10311-2010320-2012 20 7 5 9 - 10344-2010345-2014 20 7 5 8 - 10305-30 10314-30 530 5917 - 10306-30 10315-30 630 5816 - 10307-30 10316-30 730 5816 - 10308-30 10317-30 830 6915 - 10309-30 10318-30 930 6913 - 10310-3010319-3010 30 7 7 13 - 10311-30 - 12307 5 9 - 10303-4010312-403 40 5 10 18 - 10304-4010313-404 40 5 10 18 10300-4010305-4010314-405 40 5 9 17 10301-4010306-4010315-406 40 5 8 16 10302-4010307-4010316-407 40 5 8 16 - 10308-40 10317-40 840 6915 - 10309-40 10318-40 940 6913 - 10310-4010319-4010 40 7 7 13 - 10311-4010320-4012 40 7 5 8 - 10344-4010345-4014 40 7 5 8 - 10304-6010313-604 60 5 10 18 - 10305-60 10314-60 560 5917 - 10306-60 10315-60 660 5815 - 10307-60 10316-60 760 5815 - 10308-60 - 860 6915 - 10309-60 - 960 6913 - 10310-60 - 10607 7 13 - 10311-60 - 12607 5 8 - 10303-8010312-803 80 5 10 17 - 10304-8010313-804 80 5 10 17 - 10305-80 10314-80 580 5917 - 10306-80 10315-80 680 5814 - 10307-80 - 780 5813 - 10308-80 - 880 6913 - 10304-10010313-1004 100 5 10 16 - 10305-100 10314-100 5100 5915 - 10306-100 10315-100 6100 5813 - 10307-100 10316-100 7100 6812 - 10304-12010313-1204 120 5 10 15 - 10305-120 10314-120 5120 5914 - 10306-120 10315-120 6120 5812 - 10307-120 10316-120 7120 6812 SFA Jet coated balloon, shaft, tip and guide wire lumen 0.035" • Totally coated balloon system • Low profile • Advanced shaft technology 49 FOXplus One for all PTA Catheter Balloon Dilatation Catheters High strength Ordering Information 50 cm Usable Shaft Length Ref. No. •Increases safety in the dilatation of calcified lesions Controlled compliance •Designed to minimize risk of vessel trauma thanks to a predictable diameter at a given pressure Low profile Compatible with a 5F sheath up to the Ø 7 mm balloon Deflated balloon profile (measured in the middle of the balloon) - Average/Min/Max 3.0 (mm) 2.5 2.0 1.5 1.0 0.5 0.0 FOXplus Ø 6-120 Abbott Vascular FOXplus Ø 7-120 Abbott Vascular Sailor Plus Ø 6-120 Invatec Powerflex P3 Ø 7-100 Cordis Opta Pro Ø 7-100 Cordis Opti-Plast XT Ø 7-100 Bard Source: Data on file at Abbott Vascular. Advanced shaft technology Specifically developed dual lumen shaft •Enables reduced inflation/deflation time for an effective and time-saving procedure Deflation time 80% - Average/Min/Max 14.0 Time (s) 12.0 10.0 80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length Ref. No. Balloon Diameter [mm] Balloon Length [mm] Sheath Compatibility [F] Nominal Pressure (NP) [atm] Rated Burst Pressure (RBP) [atm] - AP12003AP220033 20 5 10 18 - AP12004AP220044 20 5 10 18 82360-01 AP12005 AP22005 520 5917 82362-01 AP12006 AP22006 620 5816 82364-01 AP12007 AP22007 720 5816 - AP12008 AP22008 820 6915 - AP12009 AP22009 920 6914 - AP12010AP2201010 20 7 7 13 - AP12012AP2201212 20 7 5 9 - AP13005 AP23005 530 5917 - AP13006 AP23006 630 5816 - AP13007 AP23007 730 5816 - AP13008 AP23008 830 6915 - AP13009 AP23009 930 6913 - AP13010AP2301010 30 7 7 13 - AP13012 - 12307 5 9 - AP14003AP240033 40 5 10 18 - AP14004AP240044 40 5 10 18 82361-01 AP14005 AP24005 540 5917 82363-01 AP14006 AP24006 640 5816 82365-01 AP14007 AP24007 740 5816 - AP14008 AP24008 840 6915 - AP14009 AP24009 940 6913 - AP14010AP2401010 40 7 7 13 - AP14012AP2401212 40 7 5 8 - AP16004AP260044 60 5 10 18 - AP16005 AP26005 560 5917 - AP16006 AP26006 660 5815 - AP16007 AP26007 760 5815 - AP16008 - 860 6915 - AP16009 - 960 6913 - AP16010 - 10607 7 13 - AP16012 - 12607 5 8 - 82906-0182916-013 80 5 10 17 - 82907-0182917-014 80 5 10 17 - AP18005 AP28005 580 5917 - AP18006 AP28006 680 5814 - AP18007 - 780 5813 - AP18008 - 880 6913 - 82908-0182918-014 100 5 10 16 - 82910-01 82920-01 5100 5915 - 82912-01 82922-01 6100 5813 - 82914-01 82924-01 7100 6812 - 82909-0182919-014 120 5 10 15 - 82911-01 82921-01 5120 5914 - 82913-01 82923-01 6120 5812 - 82915-01 82925-01 7120 6812 SFA Rated Burst Pressure up to 18 bar 0.035" 8.0 6.0 4.0 2.0 • High strength 0.0 FOXplus Ø 6-120 Abbott Vascular FOXplus Ø 7-100 Abbott Vascular Sailor Plus Ø 6-120 Invatec Powerflex P3 Ø 7-100 Cordis Opta Pro Ø 7-100 Cordis Opti-Plast XT Ø 7-100 Bard • Low profile Source: Data on file at Abbott Vascular. • Advanced shaft technology 50 51 Xpert The one and only Stent System Self-Expanding Stent Systems The world`s first 4F compatible self-expanding stent system1, specifically designed for small vessels with focus on hemodynamics Ordering Information Each stent diameter was specifically developed to guarantee a Nitinol/vessel wall coverage of maximum 20%. Designed for small vessels Xpert has a homogeneous and diameter independent constant arterial surface coverage (each stent diameter is specifically designed). The wall coverage is reduced compared to other NiTi stents. Radial force Radial Force [N/cm] Higher radial force compared to other .018" guidewire systems. No compromise in radial force compared to .035" guidewire systems. 1.0 0.8 120 cm Usable Shaft Length Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Reference Vessel Diameter [mm] EX8S2005EX8L2005 EX8S3005EX8L3005 EX8S4005EX8L4005 EX8S6005EX8L6005 5 5 5 5 20 30 40 60 4 4 4 4 3-4 3-4 3-4 3-4 EX8S2006EX8L2006 EX8S3006EX8L3006 EX8S4006EX8L4006 EX8S6006EX8L6006 6 6 6 6 20 30 40 60 4 4 4 5 4-5 4-5 4-5 4-5 EX8S3008EX8L3008 8 EX8S4008EX8L4008 8 EX8S6008EX8L6008 8 30 40 60 5 5-7 5 5-7 5 5-7 90 cm Usable Shaft Length Ref. No. Stent Length [mm] Introducer Compatibility [F] EX8S2003EX8L2003 3 EX8S3003EX8L3003 3 EX8S4003EX8L4003 3 20 30 40 4 2-2.5 4 2-2.5 4 2-2.5 EX8S2004EX8L2004 EX8S3004EX8L3004 EX8S4004EX8L4004 EX8S6004EX8L6004 83010-0283011-02 20 30 40 60 80 4 4 4 4 4 135 cm Usable Shaft Length Ref. No. Stent Diameter [mm] 4 4 4 4 4 Reference Vessel Diameter [mm] SFA Innovation and technology have resulted in a new generation of the Xpert small vessel stent system, now enabling the treatment of peripheral vessels from diameter 2 mm up to 7 mm. 80 cm Usable Shaft Length Ref. No. 0.018" 2.5-3.5 2.5-3.5 2.5-3.5 2.5-3.5 2.5-3.5 0.6 0.4 0.2 0.0 Xpert Ø3, 4F Xpert Ø4, 4F Xpert Ø6, 4F Xpert Ø8, 5F Comp D Ø8, 5F 0.018" Comp A Ø8, 6F 0.035" Source: Data on file at Abbott Vascular. Conformability In tortuous anatomies, a good wall apposition ensures, that the vessel lumen is not reduced and hemodynamics are maintained. Optimized hemodynamics The relative wall coverage can be compared to a standard stent in a larger vessel. The low strut profile also contributes to optimizing the vessel lumen and minimizing the flow disturbance. This design assures minimal reduction of vessel lumen when placed in a small vessel. • Designed for small vessels • Optimized hemodynamics Strut profile designed for large vessels in a large vessel Strut profile designed for large vessels in a small vessel Specifically designed Xpert strut profile in a small vessel • Conformability 1. Source: Data on file at Abbott Vascular. 52 53 Xpert Pro Slim, Tri-Layer Catheter Design Self-Expanding Stent Systems Self-Expanding Stent System Ordering Information Stent Movement During Deployment 9 Accurate stent deployment and placement through the advanced stabilizer coil. 8 Movement (mm) Less Accurate 7 6 5 4 3 4.9 2 1 0.1 5.3 3.7 More Accurate 0 Abbott Vascular Biotronik Astron Xpert Pro Pulsar Invatec Maris OptiMed Deep sinus-Superflex-418 Reach* 3.9F ngineered for excellent E deliverability in complex cases with the innovative, slim, intra-laced sheath. Lowest† catheter system profile for tight anatomies. Xpert Pro 4.6F Astron Pulsar 4.2F Maris Deep 4.2F sinus-SuperFlex-418 90 cm Catheter Length Ref. No. 135 cm Catheter Length Ref. No. Stent Diameter [mm] Stent Length [mm] Sheath Compatibility [F] Reference Vessel Diameter [mm] 17525-20 17525-30 17525-40 17525-60 17525-80 17525-100 17538-20 17538-30 17538-40 17538-60 17538-80 17538-100 3 3 3 3 3 3 20 30 40 60 80 100 4 4 4 4 4 4 2.0 - 2.5 2.0 - 2.5 2.0 - 2.5 2.0 - 2.5 2.0 - 2.5 2.0 - 2.5 17526-20 17526-30 17526-40 17526-60 17526-80 17526-100 17539-20 17539-30 17539-40 17539-60 17539-80 17539-100 4 4 4 4 4 4 20 30 40 60 80 100 4 4 4 4 4 4 2.5 - 3.5 2.5 - 3.5 2.5 - 3.5 2.5 - 3.5 2.5 - 3.5 2.5 - 3.5 80 cm Catheter Length Ref. No. 120 cm Catheter Length Ref. No. Stent Diameter [mm] Stent Length [mm] Sheath Compatibility [F] Reference Vessel Diameter [mm] 17527-20 17527-30 17527-40 17527-60 17527-80 17527-100 17540-20 17540-30 17540-40 17540-60 17540-80 17540-100 5 5 5 5 5 5 20 30 40 60 80 100 4 4 4 4 5 5 3.0 - 4.0 3.0 - 4.0 3.0 - 4.0 3.0 - 4.0 3.0 - 4.0 3.0 - 4.0 17528-20 17528-30 17528-40 17528-60 17528-80 17541-20 17541-30 17541-40 17541-60 17541-80 6 6 6 6 6 20 30 40 60 80 4 4 4 5 5 4.0 - 5.0 4.0 - 5.0 4.0 - 5.0 4.0 - 5.0 4.0 - 5.0 17529-30 17529-40 17529-60 17542-30 17542-40 17542-60 8 8 8 30 40 60 5 5 5 5.0 - 7.0 5.0 - 7.0 5.0 - 7.0 SFA Precision* 0.018" †Among competitors listed herein. Sizes tested: 4 mm x 80 mm: Xpert Pro, Astron Pulsar, Maris Deep 4 mm x 100 mm: sinus-SuperFlex 418 Tests performed by and data on file at Abbott Vascular. Optimization Smallest diameter available (3 mm) to treat the most common BTK size.** Customized Stent Design for Each Vessel Size Same Strut Thickness Slim, Tri-Layer Catheter Design Thinner Strut Thickness Thin struts for minimal vessel lumen reduction. Standard stents use the same strut thickness for every vessel size Xpert Pro is specifically designed with thinner stent struts for smaller vessels * Tests performed by and data on file at Abbott Vascular. **Lesion reference vessel diameter in XCELL trial was 2.8 ± 0.7. K. Roca-Singh, XCELL Trial Final Data Set, VIVA 2010. Lesion reference vessel diameter in DESTINY trial was 2.9 ± 0.72 for BMS and 3.0 ± 0.84 for DES. M. Bosiers, BTK Stenting: The DESTINY results, LINC Asia-Pacific 2011. DESTINY and XCELL are Investigator Sponsored Studies (ISS) – Abbott Vascular does not promote directly or indirectly any out of intended use and recommends that the IFU is read thoroughly before the use of all devices in these studies. 54 55 Absolute Pro Delivering absolute performance Peripheral Self-Expanding Stent System Self-Expanding Stent Systems Smoother stent with lower fracture rate1 Ordering Information •Stent flexibility •Stent fracture resistance in both bending and axial modes A B A. 8.0x60 mm Absolute – Abbott Vascular B. 8.0x60 mm Competitor Superior deliverability1 The innovative triaxial technology with I-BEAM laser-cut hypotube ensures: •Improved kink resistance •Accurate stent placement and deployment 80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Reference Vessel Diameter [mm] 1011914-0201011920-020 1011915-0201011921-020 1011916-0201011922-020 1011917-0201011923-020 1011918-0201011924-020 1011919-0201011925-020 5 6 7 8 9 10 20 20 20 20 20 20 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 1011914-0301011920-030 1011915-0301011921-030 1011916-0301011922-030 1011917-0301011923-030 1011918-0301011924-030 1011919-0301011925-030 5 6 7 8 9 10 30 30 30 30 30 30 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 1011914-0401011920-040 1011915-0401011921-040 1011916-0401011922-040 1011917-0401011923-040 1011918-0401011924-040 1011919-0401011925-040 5 6 7 8 9 10 40 40 40 40 40 40 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 1011914-0601011920-060 1011915-0601011921-060 1011916-0601011922-060 1011917-0601011923-060 1011918-0601011924-060 1011919-0601011925-060 5 6 7 8 9 10 60 60 60 60 60 60 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 1011914-0801011920-080 1011915-0801011921-080 1011916-0801011922-080 1011917-0801011923-080 1011918-0801011924-080 1011919-0801011925-080 5 6 7 8 9 10 80 80 80 80 80 80 6 6 6 6 6 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 1011914-1001011920-100 1011915-1001011921-100 1011916-1001011922-100 1011917-1001011923-100 1011918-1001011924-100 1011919-1001011925-100 5 6 7 8 9 10 100 6 100 6 100 6 100 6 100 6 100 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 6.4-8.2 7.1-9.1 SFA The Absolute stent design, material and surface finish assure: 0.035" I-BEAM laser-cut hypotube Stabilizing Sheath Retracting Sheath • Proven1 clinical outcomes2-4 • Fracture resistance2-5 1. Source: Data on file at Abbott Vascular. 2. M. Schillinger et al. / NEJM; Vol 354, N18: 1879-1888 /Absolute Vienna Trial 3. M. Schillinger / Circulation 2007; 115:2745-2749 4. S. Sabeti / J Endovasc Ther 2007; 14:431-437 5.O. Schlager et al / J Endovasc Ther 2005; 12:676-684 6. Comparison to Absolute Peripheral Self-Expanding Stent System - Source: Tests performed by and data on file at Abbott Vascular. 56 • Superior deliverability6 57 Absolute Pro LL Delivering absolute performance – Extending our legacy Peripheral Self-Expanding Stent System Self-Expanding Stent Systems Clinically proven1 to treat long SFA lesions2-4 Ordering Information •Lower binary restenosis rate and sustained clinical benefit with Absolute stent compared with PTA es nt D Ste Fracture Resistance l ria ate Superb durability M nt Ste ign •Quality of life significantly improved after Absolute stenting compared to PTA 80 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length Ref. No. 0.035" Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Reference Vessel Diameter [mm] 1012008-1201012014-120 1012009-1201012015-120 1012010-1201012016-120 1012011-1201012017-120 5 6 7 8 120 6 120 6 120 6 120 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 1012008-1501012014-150 1012009-1501012015-150 1012010-1501012016-150 1012011-1501012017-150 5 6 7 8 150 6 150 6 150 6 150 6 3.6-4.5 4.3-5.4 5.0-6.3 5.7-7.3 Surface Finish SFA •Excellent stent fracture resistance2-5 -Stent material and stent design for outstanding flexibility and vessel conformability -Advanced stent electro and micro polish for optimal surface finish to enhance stent durability Uncompromised deliverability1 Triaxial Technology •Triaxial technology with: -Stabilizing sheath to absorb stored energy and minimize friction during deployment -I-Beam laser-cut hypotube for longitudinal strength, flexibility and pushability during stent delivery •Ergonomic handle for easy one-handed, controlled deployment Now available in 120 mm and 150 mm lengths* 120 mm 150 mm * Artwork shown not to scale. • Clinically proven to treat long SFA lesions2-4 • Superb durability2-5 • Uncompromised deliverability 1. Source: Data on file at Abbott Vascular. 2. M. Schillinger et al. / NEJM; Vol 354, N18: 1879-1888 /Absolute Vienna Trial 3. M. Schillinger / Circulation 2007; 115:2745-2749 4. S. Sabeti / J Endovasc Ther 2007; 14:431-437 5.O. Schlager et al / J Endovasc Ther 2005; 12:676-684 58 59 Hi-Torque Command An optimal material fusion for BTK success Family of .014" Peripheral Guide Wire Guide Wires Hybrid workhorse guide wire, specifically designed for optimal BTK performance Ordering Information Dual metal technology, combining the advantages of Stainless Steel and Nitinol, provides the optimal balance of control and ease of navigation for BTK procedures. 0.014" Hi-Torque Command Ref. No. Wire Length [cm] Wire Size [inch] Tip Diameter Tip Style [inch] 2078172 2078173 190 300 0.014 0.014 0.014 0.014 Tip Stiffness [g] Shapeable2.8 Shapeable2.8 Distal Nitinol end for superb flexibility and tip durability • Maintains 1-1 torque over the length of the wire • Handling and control improved by hydrophobic coating • Two different support levels: HT Command, HT Command ES (for extra support) •Ensures smooth device compatibility Tip Load at 10 mm 4.5 4.09 4.0 3.45 3.5 3.0 BTK Stainless steel body for excellent torque and support Tip load (grams) Transitionless weld for uniform support without stress points • Two different levels of tip load: • 2.8 g • 3.5 g •Less traumatic and easier to navigate in tortuous anatomies • Hydrophilic coating on a radiopaque polymer cover for improved lubricity, gliding and visibility 2.67 2.77 HT Pilot 150 HT Command 2.5 2.0 1.5 1.0 HT Command Support Curve vs Pilot 150 0.5 0 12 HT Command ES HT Pilot 200 Source: Data on file at Abbott Vascular. 10 Force value (g) 8 6 4 HT Command ES HT Command HT Pilot 150 2 Distance from tip (mm) 240 210 192 168 144 120 96 108 84 72 60 48 36 28 24 20 16 8 12 4 0 0 Nitinol core with parabolic grind for excellent torque and control Shapeable Nitinol tip for improved tip durability 3 cm distal platinum radiopaque coils Source: Data on file at Abbott Vascular. 60 61 Hi-Torque Command ES An optimal material fusion for BTK success Family of .014" Peripheral Guide Wire Guide Wires Hybrid workhorse guide wire, specifically designed for optimal BTK performance Ordering Information Dual metal technology, combining the advantages of Stainless Steel and Nitinol, provides the optimal balance of control and ease of navigation for BTK procedures. 0.014" Hi-Torque Command ES Ref. No. Wire Length [cm] Wire Size [inch] Tip Diameter Tip Style [inch] 2078174 2078175 190 300 0.014 0.014 0.014 0.014 Tip Stiffness [g] Shapeable3.5 Shapeable3.5 Distal Nitinol end for superb flexibility and tip durability • Maintains 1-1 torque over the length of the wire • Handling and control improved by hydrophobic coating • Two different support levels: HT Command, HT Command ES (for extra support) •Ensures smooth device compatibility Tip Load at 10 mm 4.5 4.09 4.0 3.45 3.5 3.0 BTK Stainless steel body for excellent torque and support Tip load (grams) Transitionless weld for uniform support without stress points • Two different levels of tip load: • 2.8 g • 3.5 g •Less traumatic and easier to navigate in tortuous anatomies • Hydrophilic coating on a radiopaque polymer cover for improved lubricity, gliding and visibility 2.67 2.77 HT Pilot 150 HT Command 2.5 2.0 1.5 1.0 HT Command Support Curve vs Pilot 150 0.5 0 12 HT Command ES HT Pilot 200 Source: Data on file at Abbott Vascular. 10 Force value (g) 8 6 4 HT Command ES HT Command HT Pilot 150 2 Distance from tip (mm) 240 210 192 168 144 120 96 108 84 72 60 48 36 28 24 20 16 8 12 4 0 0 Nitinol core with parabolic grind for excellent torque and control Shapeable Nitinol tip for improved tip durability 3 cm distal platinum radiopaque coils Source: Data on file at Abbott Vascular. 62 63 Hi-Torque Winn Feel. Cross. Winn. Family of Chronic Occlusion Guide Wires Guide Wires The new standard in guide wires designed for chronic occlusions Ordering Information Hi-Torque Winn family’s unique design offers a selection of tip loads with excellent tactile feel, maximum torque and pushability for intraluminal crossing of challenging below-the-knee chronic occlusions.1 0.014" Hi-Torque Winn 40 Tip Shape Ref. No. 1012466 1012467 Straight4.8 Straight4.8 Hi-Torque Winn 80 Tip Shape Ref. No. Excellent tactile feel Know where you are Maximum torque Be in control 1012468 1012469 • Transitionless DURASTEEL core taper for maximum torque and excellent pushability • Intermediate hydrophilic polymer sleeve for smooth chronic occlusion crossing 1012474 1012475 Tip Stiffness [g] Straight9.7 Straight9.7 Hi-Torque Winn 200T Tip Shape Ref. No. • Exposed shapeable tip coils for maximum tactile feedback • DURASTEEL Core-to-tip for tip shape retention, control and precise steering Tip Stiffness [g] Tip Stiffness [g] Tip Diameter [in] Wire Length [cm] 0.012 190 0.012 300 Tip Diameter [in] Wire Length [cm] 0.012 190 0.012 300 Tip Diameter [in] Wire Length [cm] Tapered13.0 0.009 190 Tapered13.0 0.009 300 BTK Unique tip offerings Cross confidently • Breakthrough advancement in the art of chronic occlusion treatment • 3 tips with varying tip diameter and increasing tip stiffness to cross challenging lesions Winn 40 Winn 80 Winn 200T Feel. Cross. Winn. • Excellent tactile feel • Maximum torque • Unique tip offerings •Ideal for probing and sliding •Stiff tip ideal for drilling •Extra stiff tapered tip for penetrating Hi-Torque Winn is indicated for PTA and PTCA use. 1. Abbott Vascular physician preference testing in 39 BTK cases conducted using Hi-Torque Winn 4/10-6/10. Illustrations not drawn to scale. 64 65 SPARTACORE 14 Extra support for lower limb procedures HI-TORQUE .014" Guide Wire Guide Wires Excellent .014" support with superb steerability and an atraumatic tip Ordering Information 0.014" Ref. No. Floppy -Tip Length [cm] Wire Length [cm] •High support .014" stainless steel shaft 1005201 1005204 5 10 130* 130* •5 cm and 10 cm intermediate segments provide excellent torque response 1005202 1005205 5 10 190 190 •Soft, atraumatic shapeable tip 1005203 1005206 5 10 300 300 Engage clinical challenges with support and control •“Core-to-tip” design for precise steering and tip control •MICROGLIDE coating provides low friction and superb trackability Torque devices sold separately in packs of ten (Ref. No. 22215). *Compatible with DOC guide wire extensions (Ref. No. 22260). •PTFE coating up to distal 7 cm •4 cm radiopaque tip coil •Platinum marker to locate the wire accurately. Measured from the distal tip: 55 cm for the 130 cm length, 90 cm for the 190 cm length, 100 cm for the 300 cm length BTK •Available in 130, 190, 300 cm length Transition length 5 cm 10 cm 66 67 Hi-Torque Connect The power to connect Family of .018" Peripheral Guide Wires Guide Wires Three distinct wires with: Ordering Information • Different support levels to provide options for lesion crossing in straight to tortuous anatomies • Choice of increasing tip loads and penetration power to maximise crossing in soft to heavily calcified lesions • Outstanding torque performance and control especially in contralateral approach Hi-Torque Connect Support Hi-Torque Connect Wire Length [cm] Tip Diameter Tip Shape [inch] 1012587 145 1012588 195 1012589 300 0.018 0.018 0.018 Hi-Torque Connect Flex Ref. No. Tip Diameter Tip Shape [inch] Wire Length [cm] Tip Stiffness [g] Straight4 Straight4 Straight4 1012590 145 1012591 195 1012592 300 0.018 0.018 0.018 Hi-Torque Connect 250T Ref. No. Tip Diameter Tip Shape [inch] Tip Stiffness [g] Straight12 Straight12 Straight12 Hi-Torque Connect 250T Wire Support Supportive workhorse wire. Ideal for straight run-off with soft to moderately calcified occlusions in focal stenoses. Hi-Torque Connect Ref. No. 0.018" Wire Length [cm] 1012593 145 1012594 195 1012595 300 0.0125 0.0125 0.0125 Tip Stiffness [g] Straight30 Straight30 Straight30 Hi-Torque Connect Flex Distance from Distal Tip Penetration Power BTK Hi-Torque Connect Flex 250 kg/in2 Trackable workhorse wire. Increased tip load and flexibility for navigating tortuous anatomies with acute take-off and moderately calcified occlusions. Hi-Torque Connect 52 kg/in2 17 kg/in2 Hi-Torque Connect Hi-Torque Connect 250T Hi-Torque Connect Flex Hi-Torque Connect 250T Tip Load Hi-Torque Connect Flex Specialty CTO wire. 30 g Specially designed .0125" tapered tip with 30 gram tip load and increased penetration power, ideal for long, heavy calcifications. 12 g 4g Hi-Torque Connect Hi-Torque Connect Flex Hi-Torque Connect 250T Hi-Torque Connect 250T Tests performed by and data on file at Abbott Vascular. 68 69 STEELCORE 18 LT Extra support for lower limb procedures HI-TORQUE .018" Guide Wire Guide Wires Providing strong support and flexibility for a successful crossing Ordering Information 0.018" STEELCORE Tip Shape Wire Length Ref. No. [cm] One-to-one torque for navigation around vessel bends •Provides proximal through distal support • Marker to locate the wire accurately. Measured from the distal tip: 90 cm for the 190 cm length 100 cm for the 300 cm length 1003281* Straight 190 1003282 Straight 300 STEELCORE LT Tip Shape Wire Length Ref. No. [cm] • Available in 190 and 300 cm length 1007709* 1007709-J* Straight J 190 190 • Available in two transition lengths 1007710 1007710-J Straight J 300 300 Torque devices sold separately and in packs of ten (Ref. No. 22215). *DOC guide wire extension compatible. 70 60 50 40 BTK Grams of force at 5 mm Tip stiffness 30 20 10 0 HI-TORQUE SteelCore 18 HI-TORQUE SteelCore 18 LT Leading competitive (.018" supportive wire) Source: Data on file at Abbott Vascular. HI-TORQUE SteelCore 18 (with 5 cm platinum/nickel tip coil) Shapeable, flexible tip Proximal through distal support Proximal markers assist in determining wire position relative to guide/sheath tip MICROGLIDE coating provides low friction and enhanced trackability Radiopaque platinum tip coil helps provide accurate positioning Longer transitions are ideally suited for angled or acute take-offs HI-TORQUE SteelCore 18 LT (with 12.5 cm platinum/nickel tip coil) 70 Shapeable, durable tip 71 PTA Catheter Balloon Dilatation Catheters Extends your reach: Taking you further Ordering Information 90 cm Usable Shaft Length Ref. No. •Catheter and balloon design combine flexibility and strength to reach more distal lesions without kinking •Jet coating for smooth delivery •Thin balloon walls: very low profile without compromising balloon strength Reduces procedure time: Rapid balloon deflation •Rapid balloon deflation and a full set of 4F compatible BTK sizes to streamline procedures •Advanced catheter design provides a large contrast lumen without flow restrictions Largest diameter measured along length of balloon Maximum Deflated Balloon Profile (mm) •Streamlined tip and a low profile balloon designed to enter and cross difficult lesions Maximum Deflated Balloon Profile (mm)† 1.2 0.8 Up to 25% lower profile 1.09 1.18 0.89 0.4 0.0 Armada 14* Amphirion Deep* NanoCross* Time for Full Balloon Deflation from RBP (s)† 100 Deflation Time (s) Optimizes lesion entry and crossing: Successful dilatation 80 77 20 Up to 4 times faster Armada 14* Balloon Length [mm] A1015-020A2015-020 A1020-020A2020-020 A1025-020A2025-020 A1030-020A2030-020 A1040-020A2040-020 1.5 2.0 2.5 3.0 4.0 20 20 20 20 20 A1015-040A2015-040 A1020-040A2020-040 A1025-040A2025-040 A1030-040A2030-040 A1040-040A2040-040 1.5 2.0 2.5 3.0 4.0 40 40 40 40 40 A1020-060A2020-060 A1025-060A2025-060 A1030-060A2030-060 A1040-060A2040-060 2.0 2.5 3.0 4.0 60 60 60 60 A1015-080A2015-080 A1020-080A2020-080 A1025-080A2025-080 A1030-080A2030-080 A1040-080A2040-080 1.5 2.0 2.5 3.0 4.0 80 80 80 80 80 A1015-120A2015-120 A1020-120A2020-120 A1025-120A2025-120 A1030-120A2030-120 A1040-120A2040-120 1.5 2.0 2.5 3.0 4.0 120 120 120 120 120 A1020-200A2020-200 A1025-200A2025-200 A1030-200A2030-200 A1040-200A2040-200 2.0 2.5 3.0 4.0 200 200 200 200 • 4F sheath compatible • Nominal pressure: 8 atm 41 • RBP: 14 atm • .014" guide wire compatible 17 0 Balloon Diameter [mm] • Broad size matrix for a wide range of lesions 60 40 150 cm Usable Shaft Length Ref. No. 0.014" BTK Armada 14 Defining new possibilities in BTK Amphirion Deep* NanoCross* * Product sizes (all 150 cm catheter length) Armada 14: 4.0 x 200 mm Amphirion Deep: 3.5/4.0 x 210 mm NanoCross: 3.5/4.0 x 210 mm †Tests perfomed by and data on file at Abbott Vascular. 72 73 Armada 14 XT Redefining possibilities in BTK therapy PTA Catheter Balloon Dilatation Catheters Ability to perform in challenging situations Ordering Information Exceptional push efficiency while maintaining low balloon profile from tip to shaft •Excellent maneuverability in complex lesions •Slim Seal Technology1 enables flexible, ultra low profile for smooth delivery and re-cross Average Push Efficiency 0.180 0.160 145 cm Usable Shaft Length Ref. No. Balloon Diameter [mm] 0.014" Balloon Length [mm] F2012-0121.2 F2015-0121.5 F2020-0122.0 12 12 12 F2012-0201.2 F2015-0201.5 F2020-0202.0 20 20 20 0.157 0.140 0.108 0.120 0.100 0.080 0.060 0.051 0.039 0.040 0.020 0.000 Armada 14 XT* Coyote* NanoCross* Amphirion Plus* Deflated Balloon Profile (in) BTK 0.0500 Armada 14 XT* Coyote* NanoCross* Amphirion Plus* 0.0450 0.0400 0.0350 0.0300 0.0250 • 4F sheath compatible 0.0200 0.0150 Distal 2/3 1/2 1/4 1 mm Crossing Tip Shaft Balloon Balloon Balloon Balloon Profile Entry Profile Profile Profile Profile Profile Profile • Broad size matrix for a wide range of lesions • Nominal pressure: 8 atm 2/3 Balloon Profile Distal Shaft Profile 1/4 Balloon Profile Mid Balloon Profile 1 mm Balloon Profile Tip Entry Profile • RBP: 14 atm • .014" guide wire compatible Crossing Profile 1Slim Seal technology available on 2.0 mm Armada 14 XT. *Tests performed by and data on file at Abbott Vascular. Product sizes tested: Armada 14 XT: 2.0 x 20 mm x 145 cm, Coyote: 2.0 x 60 mm x 150 cm, NanoCross: 2.0 x 20 mm x 150 cm, Amphirion Plus: 2.0 x 14 mm x 150 cm (n=5) 74 75 FOXsv Mastering the small vessel challenge Balloon Dilatation Catheters High pressure balloon Profile – 4F introducer compatible High Rated Burst Pressure – up to 22 bar Low entry profile •Eases insertion through tight or occluded lesions •Enables safer treatment of highly calcified lesions Dual lumen shaft design – Rapid inflation/deflation •Enables to shorten procedure and reduce patient discomfort Deflation time 80% – Average/Min/Max Time (s) 25.0 20.0 15.0 10.0 5.0 0.0 Abbott Vascular FOXsv Ø 4-120 Abbott Vascular Submarine Plus Ø 4-120 Invatec Amphirion* Ø 4-120 Invatec Savvy Ø 4-100 Cordis Symmetry Ø 4-100 Boston Scientific Source: Data on file at Abbott Vascular. * This measurement runs out of maximum time record of 20 s. Excellent balloon rewrap – Minimal deflated balloon profile •Enables better recrossing of lesions/stents •Eases insertion and withdrawal through introducer sheaths 12.0 Ordering Information 90 cm Usable Shaft Length Ref. No. 135 cm Usable Shaft Length Ref. No. 150 cm Usable Shaft Length Ref. No. Balloon Diameter [mm] 82158-54-0182157-54-01- 4.0 82168-54-0182167-54-01- 5.0 82144-54-01- 83143-54-012.0 82373-54-01- 83372-54-012.5 82150-54-01- 83149-54-013.0 82160-54-0182159-54-01- 4.0 82170-54-0182169-54-01- 5.0 82180-54-0182179-54-01- 6.0 82146-54-01- 83145-54-012.0 82375-54-01- 83374-54-012.5 82152-54-01- 83151-54-013.0 82162-54-0182161-54-01- 4.0 82172-54-0182171-54-01- 5.0 82148-54-01- 83147-54-012.0 82377-54-01- 83376-54-012.5 82154-54-01- 83153-54-013.0 82164-54-0182163-54-01- 4.0 82174-54-0182173-54-01- 5.0 82184-54-0182183-54-01- 6.0 82198-54-01- 83197-54-012.0 82379-54-01- 83378-54-012.5 82156-54-01- 83155-54-013.0 82166-54-0182165-54-01- 4.0 82176-54-0182175-54-01- 5.0 82186-54-0182185-54-01- 6.0 82946-54-01- 83964-54-012.0 82949-54-01- 83967-54-012.5 82952-54-01- 83970-54-013.0 82955-54-0182973-54-01- 4.0 82958-54-0182976-54-01- 5.0 82961-54-0182979-54-01- 6.0 82947-54-01- 83965-54-012.0 82950-54-01- 83968-54-012.5 82953-54-01- 83971-54-013.0 82956-54-0182974-54-01- 4.0 82959-54-0182977-54-01- 5.0 82962-54-0182980-54-01- 6.0 82948-54-01- 83966-54-012.0 82951-54-01- 83969-54-012.5 82954-54-01- 83972-54-013.0 82957-54-0182975-54-01- 4.0 82960-54-0182978-54-01- 5.0 82963-54-0182981-54-01- 6.0 Balloon Length [mm] Sheath Compatibility [F] Nominal Pressure (NP) [atm] Rated Burst Pressure (RBP) [atm] 15 15 4 4 6 6 20 20 20 20 20 20 20 20 4 4 4 4 4 4 12 12 8 6 6 6 22 22 22 20 20 17 30 30 30 30 30 4 4 4 4 4 12 12 8 6 6 22 22 20 20 20 40 40 40 40 40 40 4 4 4 4 4 4 12 12 8 6 6 6 22 22 20 20 20 17 60 60 60 60 60 60 4 4 4 4 4 4 12 12 8 6 6 6 22 22 20 18 17 17 80 80 80 80 80 80 4 4 4 4 4 4 12 12 8 6 6 6 22 22 20 16 16 15 100 100 100 100 100 100 4 4 4 4 4 4 12 12 8 6 6 6 22 22 20 16 16 15 120 120 120 120 120 120 4 4 4 4 4 4 12 12 8 6 6 6 22 22 20 16 16 15 BTK PTA Catheter FOXsv Ø 4-100 0.018" Maximum withdrawal force after inflation up to 20 bar – Average/Min/Max Force (N) 10.0 8.0 6.0 4.0 • Designed for small vessels 2.0 0.0 FOXsv Ø 4-100 4F introducer Abbott Vascular FOXsv Ø 4-120 4F introducer Abbott Vascular Submarine Plus Ø 4-120 4F introducer Invatec Amphirion Ø 4-120 4F introducer Invatec Savvy Ø 4-100 5F introducer Cordis Symmetry Ø 4-100 5F introducer Boston Scientific Source: Data on file at Abbott Vascular. 76 • Optimized hemodynamics • Conformability 77 XIENCE Prime BTK Market-leading drug eluting stent platform Everolimus Eluting Peripheral Stent System Drug Eluting Stent Systems Excellent long-term patency of conformable XIENCE platform Ordering Information Ref. No. XIENCE V Pre-procedure2 XIENCE V Post-procedure2 Stent Diameter [mm] 1012646-282.5 1012646-382.5 1012648-283.0 1012648-383.0 1012649-283.5 1012649-383.5 1012650-284.0 1012650-384.0 1 0.014" Stent Length [mm] Nominal RBP Expansion Pressure [atm] [atm] Max Stent Diameter [mm] 28 38 28 38 28 38 28 38 8 8 10 10 10 10 10 10 3.25 3.25 3.75 3.75 4.5 4.5 4.5 4.5 18 18 18 18 18 18 18 18 12 months post-procedure2 Designed for outstanding performance Clinical advantages of DES 100% Primary Patency (%) 80% p=0.0001 60% XIENCE V MULTI-LINK VISION 40% Procedure 6 Months 54.4% 12 Months Freedom from Target Lesion Revascularization (%) 100% 85.2% Thin Struts 37% increased freedom from re-interventions5 •For excellent flexibility, conformability and minimal vessel lumen reduction 91.3% p=0.005 80% 66.4% 60% 40% BTK 56% improved primary patency at 12 months 3,4 Controlled Everolimus Drug Release •Efficacious low-dose potent antiproliferative drug combined in a polymeric coating XIENCE V MULTI-LINK VISION 20% 0% Procedure 6 Months 12 Months Low Profile •Designed to access and cross difficult lesions “DES has proven to yield statistically significantly better results than PTA alone or placement of bare metal stents for the treatment of short BTK lesions, and can therefore be recommended as primary treatment in these lesion configurations.” 6 Efficacy, Conformability, Deliverability DESTINY is an Investigator Sponsored Study (ISS). Abbott Vascular does not directly or indirectly promote any off-label use and recommends that the IFU is read thoroughly before the use of all devices in this study. 1. Q4 2011 publicly reported DES sales; XIENCE platform includes XIENCE V, XIENCE PRIME, and XIENCE nano. Data on file at Abbott Vascular. 2. M. Bosiers, DESTINY, LINC 2011. 3. DESTINY is a multi-center, randomized trial designed to evaluate safety and efficacy of XIENCE V vs. MULTI-LINK VISION in CLI lesions (Rutherford 4,5) on 140 patients. 4. M. Bosiers, DESTINY, LINC 2011. 5. M. Bosiers, D. Scheinert, P. Peeters, G. Torsello, T. Zeller, K. Deloose, J. Tessarek, E. Vinck, L. Schwartz, Randomized comparison of everolimus-eluting versus bare-metal stents in patients with critical limb ischemia and infrapopliteal arterial occlusive disease. J Vasc Surg 2012 Feb;55(2):390-398. 6. M. Bosiers, K. Deloose, J. Callaert, K. Keirse, J. Verbist, P. Peeters, Drug-eluting stents below the knee. J Cardiovasc Surg 2011 April;52(2):231-4, pg. 234. 78 79 Xpert The one and only Stent System Self-Expanding Stent Systems The world`s first 4F compatible self-expanding stent system1, specifically designed for small vessels with focus on hemodynamics Ordering Information Innovation and technology have resulted in a new generation of the Xpert small vessel stent system, now enabling the treatment of peripheral vessels from diameter 2 mm up to 7 mm. Each stent diameter was specifically developed to guarantee a Nitinol/vessel wall coverage of maximum 20%. Designed for small vessels Xpert has a homogeneous and diameter independent constant arterial surface coverage (each stent diameter is specifically designed). The wall coverage is reduced compared to other NiTi stents. Radial force 0.8 120 cm Usable Shaft Length Ref. No. Stent Diameter [mm] Stent Length [mm] Introducer Compatibility [F] Reference Vessel Diameter [mm] EX8S2005EX8L2005 EX8S3005EX8L3005 EX8S4005EX8L4005 EX8S6005EX8L6005 5 5 5 5 20 30 40 60 4 4 4 4 3-4 3-4 3-4 3-4 EX8S2006EX8L2006 EX8S3006EX8L3006 EX8S4006EX8L4006 EX8S6006EX8L6006 6 6 6 6 20 30 40 60 4 4 4 5 4-5 4-5 4-5 4-5 EX8S3008EX8L3008 8 EX8S4008EX8L4008 8 EX8S6008EX8L6008 8 30 40 60 5 5-7 5 5-7 5 5-7 90 cm Usable Shaft Length Ref. No. Stent Length [mm] Introducer Compatibility [F] EX8S2003EX8L2003 3 EX8S3003EX8L3003 3 EX8S4003EX8L4003 3 20 30 40 4 2-2.5 4 2-2.5 4 2-2.5 EX8S2004EX8L2004 EX8S3004EX8L3004 EX8S4004EX8L4004 EX8S6004EX8L6004 83010-0283011-02 20 30 40 60 80 4 4 4 4 4 135 cm Usable Shaft Length Ref. No. Stent Diameter [mm] 4 4 4 4 4 Reference Vessel Diameter [mm] 2.5-3.5 2.5-3.5 2.5-3.5 2.5-3.5 2.5-3.5 0.6 0.4 BTK Radial Force [N/cm] Higher radial force compared to other .018" guidewire systems. No compromise in radial force compared to .035" guidewire systems. 1.0 80 cm Usable Shaft Length Ref. No. 0.018" 0.2 0.0 Xpert Ø3, 4F Xpert Ø4, 4F Xpert Ø6, 4F Xpert Ø8, 5F Comp D Ø8, 5F 0.018" Comp A Ø8, 6F 0.035" Source: Data on file at Abbott Vascular. Conformability In tortuous anatomies, a good wall apposition ensures, that the vessel lumen is not reduced and hemodynamics are maintained. Optimized hemodynamics The relative wall coverage can be compared to a standard stent in a larger vessel. The low strut profile also contributes to optimizing the vessel lumen and minimizing the flow disturbance. This design assures minimal reduction of vessel lumen when placed in a small vessel. • Designed for small vessels • Optimized hemodynamics Strut profile designed for large vessels in a large vessel Strut profile designed for large vessels in a small vessel Specifically designed Xpert strut profile in a small vessel • Conformability 1. Source: Data on file at Abbott Vascular. 80 81 Xpert Pro Slim, Tri-Layer Catheter Design Self-Expanding Stent Systems Self-Expanding Stent System Ordering Information Stent Movement During Deployment 9 Accurate stent deployment and placement through the advanced stabilizer coil. 8 Movement (mm) Less Accurate 7 6 5 4 3 4.9 2 1 0.1 5.3 3.7 More Accurate 0 Abbott Vascular Biotronik Astron Xpert Pro Pulsar Invatec Maris OptiMed Deep sinus-Superflex-418 Reach* 3.9F ngineered for excellent E deliverability in complex cases with the innovative, slim, intra-laced sheath. Lowest† catheter system profile for tight anatomies. Xpert Pro 4.6F Astron Pulsar 4.2F Maris Deep 4.2F sinus-SuperFlex-418 90 cm Catheter Length Ref. No. 135 cm Catheter Length Ref. No. Stent Diameter [mm] Stent Length [mm] Sheath Compatibility [F] Reference Vessel Diameter [mm] 17525-20 17525-30 17525-40 17525-60 17525-80 17525-100 17538-20 17538-30 17538-40 17538-60 17538-80 17538-100 3 3 3 3 3 3 20 30 40 60 80 100 4 4 4 4 4 4 2.0 - 2.5 2.0 - 2.5 2.0 - 2.5 2.0 - 2.5 2.0 - 2.5 2.0 - 2.5 17526-20 17526-30 17526-40 17526-60 17526-80 17526-100 17539-20 17539-30 17539-40 17539-60 17539-80 17539-100 4 4 4 4 4 4 20 30 40 60 80 100 4 4 4 4 4 4 2.5 - 3.5 2.5 - 3.5 2.5 - 3.5 2.5 - 3.5 2.5 - 3.5 2.5 - 3.5 80 cm Catheter Length Ref. No. 120 cm Catheter Length Ref. No. Stent Diameter [mm] Stent Length [mm] Sheath Compatibility [F] Reference Vessel Diameter [mm] 17527-20 17527-30 17527-40 17527-60 17527-80 17527-100 17540-20 17540-30 17540-40 17540-60 17540-80 17540-100 5 5 5 5 5 5 20 30 40 60 80 100 4 4 4 4 5 5 3.0 - 4.0 3.0 - 4.0 3.0 - 4.0 3.0 - 4.0 3.0 - 4.0 3.0 - 4.0 17528-20 17528-30 17528-40 17528-60 17528-80 17541-20 17541-30 17541-40 17541-60 17541-80 6 6 6 6 6 20 30 40 60 80 4 4 4 5 5 4.0 - 5.0 4.0 - 5.0 4.0 - 5.0 4.0 - 5.0 4.0 - 5.0 17529-30 17529-40 17529-60 17542-30 17542-40 17542-60 8 8 8 30 40 60 5 5 5 5.0 - 7.0 5.0 - 7.0 5.0 - 7.0 BTK Precision* 0.018" †Among competitors listed herein. Sizes tested: 4 mm x 80 mm: Xpert Pro, Astron Pulsar, Maris Deep 4 mm x 100 mm: sinus-SuperFlex 418 Tests performed by and data on file at Abbott Vascular. Optimization Smallest diameter available (3 mm) to treat the most common BTK size.** Customized Stent Design for Each Vessel Size Same Strut Thickness Slim, Tri-Layer Catheter Design Thinner Strut Thickness Thin struts for minimal vessel lumen reduction. Standard stents use the same strut thickness for every vessel size Xpert Pro is specifically designed with thinner stent struts for smaller vessels * Tests performed by and data on file at Abbott Vascular. **Lesion reference vessel diameter in XCELL trial was 2.8 ± 0.7. K. Roca-Singh, XCELL Trial Final Data Set, VIVA 2010. Lesion reference vessel diameter in DESTINY trial was 2.9 ± 0.72 for BMS and 3.0 ± 0.84 for DES. M. Bosiers, BTK Stenting: The DESTINY results, LINC Asia-Pacific 2011. DESTINY and XCELL are Investigator Sponsored Studies (ISS) – Abbott Vascular does not promote directly or indirectly any out of intended use and recommends that the IFU is read thoroughly before the use of all devices in these studies. 82 83 StarClose SE Vascular Closure System Extravascular evolution 5-6F Vessel Closure Clip Closure The Secure*, Easy, Extravascular solution for vascular access management Ordering Information Ref. No. Description Quantity Circumferential 360˚ mechanical closure. 14679-02 A system includes: 10 systems per box Secure* •Device design features for procedural success • Clip Applier • 6F Exchange Sheath • 6F Dilator • 0.038" 50 cm J-Tip Guide Wire •Through the sheath deployment - minimized device exchanges Easy •Updated device design has improved ergonomics, stability and a more intuitive user interface Extravascular 360° closure •The Clip is designed to close the adventitia and media, leaving nothing inside the artery •No disruption of flow or velocity Actual diameter of the closed Clip: 4 mm Vessel closure Actual thickness of the closed Clip: 0.2 mm • Secure* • Extravascular • Easy and quick • 360˚ closure *Data on file at Abbott Vascular. 84 85 Perclose ProGlide Suture-Mediated Closure System Secure* •The preferred suture of vascular surgeons1 • Mechanical closure – hemostasis is not clot dependent • Hemostasis can be challenged and confirmed on the table Simple The security of suture 5-8F Vessel Closure Suture-Mediated Closure Ordering Information Ref. No. Description Quantity 12673-05 A system includes: 10 systems per box • 1 Perclose ProGlide 6F Suture-Mediated Closure Device • 1 Suture Trimmer • 1 Snared Knot Pusher •Single operator procedure with QuickCut mechanism • Pre-tied knot • Simplified knot delivery • Numbered deployment sequence Control •Immediate re-access • Vascular access can be maintained throughout deployment • Ability to pre-close over the wire • Reduced time to hemostasis, ambulation and discharge Over-Molded Sheath Single piece •Incorporates guide wire exit ramp and white markers for visibility • Allows smooth transition during device insertion and withdrawal • Secure* • Simple • Control Vessel closure Kink resistant •Single-piece construction reduces potential for kinking during insertion A History of Innovation *Data on file at Abbott Vascular. 1. Source: Data on file at Abbott Vascular. 86 87 Prostar XL Perclose Percutaneous Femoral Artery Closure Close larger access sites up to 24F • Percutaneous vascular closure device • Integrated pre-dilator to facilitate device placement Clinical leader for percutaneous large access site closure Vessel Closure < 24F Suture-Mediated Closure Ordering Information Ref. No. Description Quantity 12322-02 A system includes: 5 systems per box • 1 Prostar XL • 1 Knot Pusher Secure* closure • Uses two braided polyester sutures and four nitinol needles to provide a secure* close • Vascular access can be maintained throughout deployment • Close access sites up to 24F • Secure* closure • Improved outcomes Improved outcomes Vessel closure • Reduces time to hemostasis, ambulation and discharge • Improves patient comfort and reduces access site complications *Data on file at Abbott Vascular. 88 89 Accessories Accessories Accessory kits •Priority packs Designed to minimize blood loss for a cleaner, safer procedure Economically bundled combinations of: 1. Indeflator 2. Copilot Or RHV 3. Guide Wire Introducer 4. Torque Device 20/20 priority pack and 20/30 priority pack with RHV (Rotating HemostaticValve) PTA priority pack 1 Ref. No. Compatible Contents Syringe [cc/ml] Gauge [bar/ATM] Diameter [inch/mm] 1003327 20/30 Indeflator Inflation Device 20 30 Copilot Bleedback Control Valve .096/2.44 Guide Wire Introducer Torque Device Guide Wires [inch/mm] Ref. No. Compatible Contents Syringe [cc/ml] Gauge [bar/ATM] Diameter [inch/mm] 22297 1000186 22297-115 1000186-115 20/20 Indeflator Inflation Device 20 20 .096 Rotating Hemostatic Valve .096/2.44 Guide Wire Introducer Torque Device 20/30 Indeflator Inflation Device 20 30 .096 Rotating Hemostatic Valve .096/2.44 Guide Wire Introducer Torque Device 20/20 Indeflator Inflation Device 20 20 .115 Rotating Hemostatic Valve .115/2.92 Guide Wire Introducer Torque Device 20/30 Indeflator Inflation Device 20 30 .115 Rotating Hemostatic Valve .115/2.92 Guide Wire Introducer Torque Device Guide Wires [inch/mm] .010 – .018/.25 – .45 .010 – .018/.25 – .45 .010 – .018/.25 – .45 .010 – .018/.25 – .45 .010 – .018/.25 – .45 .010 – .018/.25 – .45 .010 – .018/.25 – .45 .010 – .018/.25 – .45 .010 – .018/.25 – .45 .010 – .018/.25 – .45 t 20/20 priority pack and 20/30 priority pack with Copilo PTA priority pack 2 22296 90 Compatible Contents Syringe [cc/ml] Gauge [bar/ATM] Diameter [inch/mm] Indeflator Plus 20 Inflation Device 10 20 .096 Rotating Hemostatic Valve .096/2.44 Guide Wire Introducer Torque Device Guide Wires [inch/mm] .010 – .018/.25 – .45 .010 – .018/.25 – .45 Compatible Contents Syringe [cc/ml] Gauge [bar/ATM] Diameter [inch/mm] 1003326 1003327 20/20 Indeflator Inflation Device 20 20 Copilot Bleedback Control Valve .096/2.44 Guide Wire Introducer Torque Device 20/30 Indeflator Inflation Device 20 30 Copilot Bleedback Control Valve .096/2.44 Guide Wire Introducer Torque Device Guide Wires [inch/mm] accessories Ref. No. Ref. No. .010 – .018/.25 – .45 .010 – .018/.25 – .45 .010 – .018/.25 – .45 .010 – .018/.25 – .45 91 Accessories Accessories Hemostatic valves Ref. No. Description Inner diameter [inch/mm] 1003331 Copilot Bleedback Control Valve .096/2.44 Ref. No. Description Inner diameter [inch/mm] 23242 23245 .096 Rotating Hemostatic Valve .115 Rotating Hemostatic Valve .096/2.44 .115/2.92 Syringe [cc/ml] Gauge [bar/atM] 24310 1000184 20/20 Indeflator Inflation Device 20/30 Indeflator Inflation Device 20 20 20 30 • Torque device: Provides grip for steering guide wires in the anatomy. • Guide wire introducer: Engineered to allow easy access of wires through RHVs, while preventing wire tip damage. Duostat Rotating Hemostatic Valve Ref. No. Description Inner diameter [inch/mm] 23244 23246 Duostat Rotating Hemostatic Valve Duostat Rotating Hemostatic Valve. .096/2.44 .115/2.92 Ref. No. Description Compatible Guide Wires [inch/mm] 22215 Torque Device - 10 Pack .009 – .018/.22 – .45 Ref. No. Description Compatible Guide Wires [inch/mm] 22290 22231 Guide Wire Introducer - 10 Pack Funnel Introducer - 10 Pack .009 – .018/.22 – .45 .009 – .018/.22 – .45 Introducers Indeflator Plus 20 Inflation Device Ref. No. Description Syringe [cc/ml] Gauge [bar/atM] 24301 Indeflator Plus 20 Inflation Device 10 20 Guide Wire Kit with RHV Ref. No. Description Diameter Compatible Guide Wires [inch/mm] 22295 Guide Wire Introducer and Torque Device .096 Rotating Hemostatic Valve. Guide Wire Introducer and Torque Device .115 Rotating Hemostatic Valve. .096/2.44 .009 – .018/.22 – .45 .115/2.92 .009 – .018/.22 – .45 22295-115 Guide Wire Kit with Copilot Ref. No. Description Diameter Compatible Guide Wires [inch/mm] 1003330 Guide Wire Introducer and Torque Device Copilot Bleedback Control Valve. .096/2.44 .009 – .018/.22 – .45 accessories • 20/20 Indeflator & 20/30 Indeflator: Ergonomic design for device inflation to a maximum of 20 or 30 atmospheres pressure. • Plus 20 Indeflator & Plus 30 Indeflator: Standard design for inflation to a maximum of 20 or 30 atmospheres pressure. Indeflators Description Torque Devices Indeflators 92 Ref. No. Guide wire accessories Rotating Hemostatic Valve Guide wire accessories & kits Hemostatic valves Copilot Bleedback Control Valve Indeflators 20/20 Indeflator Inflation Device and 20/30 Indeflator Inflation Device • Copilot bleedback control valve: Designed to minimize blood loss for a cleaner, safer procedure Available in .096”/2.44 mm ID. • Rotating Hemostatic Valve (RHV): Standard RHV available in .096"/2.44 mm and .115”/2.92 mm sizes. • Duostat rotating hemostatic valve: Double valve design for multiple device delivery. Available in .096”/2.44 mm and .115”/2.92 mm sizes. Indeflator Plus 30 Inflation Device Ref. No. Description Syringe [cc/ml] Gauge [bar/atM] 1000183 Indeflator Plus 30 Inflation Device 10 30 93 Notes Notes 94 95 96
Similar documents
benda-lutz® maxal ec aluminium pigments
2. Benefits of BENDA-LUTZ® MAXAL EC-Pigments Very good moisture and chemical resistance1) Best outdoor durability2) High brilliance and brightness Distinctive sparkle-effect, intense flop Very pure...
More information