StormBreaker Plus Window Installation
Transcription
StormBreaker Plus Window Installation
Window Installation Instructions *100220114001* *100220114001* Installation Instructions Table of Contents StormBreaker Plus® 300VL Install Instructions Retrofit Frame Details.................................... 2-4 Geometric............................................................................................................................................5 Double Hung................................................................................................................................... 6-7 Double Hung Twin........................................................................................................................... 8-9 Horizontal Roller.......................................................................................................................... 10-11 Awning......................................................................................................................................... 12-13 Casement.................................................................................................................................... 14-15 Casement Twin............................................................................................................................ 16-17 Picture Window........................................................................................................................... 18-19 New Construction Frame Details Double Hung............................................................................................................................... 20-21 Horizontal Roller.......................................................................................................................... 22-23 Awning......................................................................................................................................... 24-25 Casement.................................................................................................................................... 26-27 Picture Window........................................................................................................................... 28-29 Simonton StormBreaker Simonton StormBreaker Plus® Vinyl Window Products Plus® Vinyl Window Products IMPORTANT INFORMATION COASTAL INSTALLATIONS: that installation the following installation IMPORTANT INFORMATION FOR FOR COASTAL REGIONREGION INSTALLATIONS: Note that theNote following recommendarecommendations reflectrequirements the performance requirements (Missileinstallations D) as tested for product installations in tions reflect the performance (Missile D) as tested for product in coastal regions. For Florida coastal regions. For Florida installations, please approval reference the as appropriate product approval installations, please reference the appropriate Florida product number listed on theFlorida temporary NFRC label. For number anchorage as listed on the temporary NFRC label. Forplease additional anchorage requirements for in additional requirements for installations in Florida, reference (www.floridabuilding.org). Forinstallations additional For additional anchorage requirements for installations in Florida, please reference (www.floridabuilding.org). anchorage requirements for installations in the Texas, please reference (www.tdi.state.tx.us). the Texas, please reference (www.tdi.state.tx.us). ALL PRODUCTS: The following installation instructions refer to how a specific unit size/style was tested for performance. ALL PRODUCTS: installation refer towill how a specific unitof size/style was tested for Attention to the frame The type following (Retrofit, Flange or Fin &instructions J/New Construction) determine the type anchorage needed. These recommended instructions were created to (Retrofit, help minimize the number needed without will loss determine of expected the performance. Attention to the frame type Flange or Fin of & anchors J/New Construction) performance on these products drawings indicate the installation required a product to perform to its certifications. type of anchorage needed. the These recommended instructions werefor created to help minimize the number of However, installer is nevertheless to identify and properly installationthe situations that might not bethe anchorseach needed without loss ofrequired expected performance onrespond these toproducts drawings indicate addressed by these instructions because to of the uniqueto nature or design of the premises, selection or coninstallation required for a product perform its certifications. However,product each installer is other nevertheless struction/field These instructions alter the responsibility the construction professionals, required to circumstances. identify and properly responddotonot installation situationsofthat might not be addressedincludby these ing but not limited to the installer, to possess of construction principlesproduct and experience to select instructions because of the unique sufficient nature knowledge or design of the premises, selection or the other appropriate product and perform the installation a professional,do accurate, complete, and responsibleofmanner. Simonton is construction/field circumstances. These ininstructions not alter the responsibility the construction not responsible forincluding any third party’s workmanship decisions. professionals, but not limited toorthe installer, to possess sufficient knowledge of construction principles and experience to select the appropriate product and perform the installation in a professional, LABELING: the windows Simonton’smanner. manufacturing facility, each will have one permanent that accurate, When complete, and leave responsible Simonton is not responsible for label any attached third party’s clearly shows theor name Simonton StormBreaker Plus®, Simonton® or Simonton Windows® (AAMA Sticker). Additional workmanship decisions. removable labels will also be attached to the windows to reflect thermal values when applicable. LABELING: When the windows leave Simonton’s manufacturing facility, each will have one permanent label attached that clearly shows INSTRUCTIONS the name Simonton Plus®, Simonton® or Simonton INSTALLATION –ForStormBreaker Simonton StormBreaker Plus® 300VL WindowsWindows® (AAMA Sticker). Additional removable labels will also be attached the windows to reflect thermal values when applicable. Double Hung, Horizontal Roller, Awning, to Casement, Picture, Geometric INSTALLATION INSTRUCTIONS –For Simontonrequirement StormBreaker Plus® 300VL Windows The installation instructions below offer a minimum for installing the Simonton StormBreaker Plus® products. Double Hung, Horizontal Roller, Casement, Picture, Geometric The details in these instructions referAwning, to “as tested” 2x substrate installation methodology. If your installation substrate is something other than a 2x construction, please refer to your State and/or Local Code requirements to ensure that the prodThemaintain installation instructions below offer aand minimum requirement the Simonton StormBreaker Plus® products. ucts their designed performance integrity. Dependingfor oninstalling your locality a Professional Engineer may need to The details intothese instructions refer to “as tested” 2xquantity substrate installation methodology. If your installation substrate be contracted supply appropriate substitution anchor and placement. For FL and TX coastal customers, please is something other than a 2x construction, please refer respectively to your State Local Codeonrequirements to ensureanchors that the refer to www.floridabuilding.org and www.tdi.state.tx.us forand/or more information acceptable substitute products maintain their designed performance and integrity. Depending on your locality a Professional Engineer may and substrates. need to be contracted to supply appropriate substitution anchor quantity and placement. For FL and TX coastal www.tdi.state.tx.us respectively forare more information customers, please refer and to www.floridabuilding.org Note that anchor placement spacing change by style and and the number of additional anchors that required from the on acceptable substitute anchors and substrates. frame to the opening and also through some pieces of hardware supplied with the product. Anchors at hardware locations have been detailed out in the following installation drawings by style as a result. Note that anchor placement and spacing change by style and the number of additional anchors that are required from the frame to the opening and also through some pieces of hardware supplied with the product. Anchors at hardware locations have been detailed out in the following installation drawings by style as a result. 1. Begin by verifying the window is the correct size for the opening. a. For a new construction application, the mounting flange of the window must be sealed with the proper grade 1 Begin by of verifying sealant and per building to prevent air and water infiltration around the window. the flashing, window is the correctcode size specifications, for the opening. The proper grade will depend on the surface that the mounting be sealed Always sure a. For a new construction application, the mounting flange flange of thewill window mustagainst. be sealed withmake the proper that the material used is compatible. grade of sealant and flashing, per building code specifications, to prevent air and water infiltration around b. Run athe continuous minimum bead sealant on around the inside of theflange mounting flange aligned window. The proper3/8” grade willofdepend the surface thatperimeter the mounting will be sealed against. with Always pre-punched holes (See Fig. A). make sure that the material used is compatible. b. Run a continuous minimum 3/8" bead of sealant around the inside perimeter of the mounting flange aligned with pre-punched holes (See Fig. A). 2 Accessories are available from Simonton to ease the installation and finishing of the new window. When using exterior accessories such as a sill extender or snap in flange, sealant must be applied in the accessory groove of the frame prior to application to prevent leaks. For more information on accessories and their applications contact a Simonton Distributor. Accessories are available from Simonton to ease the installation and finishing of the new window. When using exterior as a(leveling sill extender in flange,Itsealant must to beremember applied inthat thethe accessory the the frame prior 2.accessories Prepare thesuch opening off theorsillsnap if necessary). is important window groove MUST fitofinto toopening application to prevent leaks. Foreven morethough information on accessories and their applications contactisa NOT Simonton Distributor. plumb, level and square, the opening may not be any of these. If the window plumb, level and square the following problems may occur: the opening (leveling off the sillbe if necessary). It is important to remember that the window MUST fit into the 2 Prepare • Double Hung and Slider sash may difficult or impossible to remove. level sash and may square, though the due opening may notdrag be any of sill. these. If the window is NOT plumb, level opening plumb, • Casement not even operate properly to excessive on the thesash following may Hung occur:windows could bind and cause the sash to become inoperative. and square • The pivot problems bar on Double • The interlocking meeting rail on Double Hung and Slider windows may not perform properly — allowing air and • Double Hung and Slider sash may be is difficult or impossible to remove. water infiltration, even if the sash locked. • Casement sash may not operate properly due to excessive theinfiltration. sill. • The weather-stripping may not seal properly, allowing airdrag and on water • The sash pivot bar on Double Hung windows could bind and cause the sash to become inoperative. • The locking system may not engage properly. • The interlocking meeting rail on Double Hung and Slider windows may not perform properly — allowing air and water infiltration, if the sash is the locked. 3. Tilt the window up intoeven the opening with sash closed and locked. Set it down on the window sill making sure the • The weather-stripping may not seal properly, allowing air and water infiltration. sill is level. • The locking system may not engage properly. 4. Tighten the jamb adjusters and shim the window accordingly where necessary to hold the unit secure while checking 3 Tilt the window up into the opening with the sash closed and locked. Set it down on the window sill making sure the sill it for plumb, level, and square. Be careful not to over tighten jamb adjusters or over shim to avoid twisting or deflection is level. of jambs. 4 Tighten the jamb adjusters and shim the window accordingly where necessary to hold the unit secure while checking it for plumb, • Tolevel, checkand plumb: Place level vertically on both the interior and faceor of over the left andtoright jambs. If the of square. Bea careful not to over tighten jamb adjusters shim avoid twisting orbubble deflection jambs. indicator is centered, the unit is plumb (Fig. B). • To check level: Place a level along the sill. If the bubble indicator is centered, the unit is level (Fig. C). To check square: Measure frame Measure from theof topthe leftleft corner the frame • To •check plumb: Place a levelwindow vertically ondiagonally. both the interior and face andofright jambs.toIfthe thebot bubble tom right corner and from the top right to bottom left. If the measurements are equal, the window is square indicator is centered, the unit is plumb (Fig. B). (Fig.D). YouPlace can also check thethe squareness closing the sashisto the pointthe where meets • To check level: a level along sill. If theby bubble indicator centered, unititisjust level (Fig.the C).head or sill. If both sides of the sash meet the head or sill at the same time, the window is square. • To check square: Measure window frame diagonally. Measure from the top left corner of the frame to the bottom right corner and from the top right to bottom left. If the measurements are equal, the window is square (Fig. D). You can also check the squareness by closing the sash to the point where it just meets the head or sill. If both sides of the sash meet the head or sill at the same time, the window is square. 5.5 Check thethe sash where theythey meet the frame to betocertain the weather stripping is sealing properly in all areas. all Check sash where meet the frame be certain the weather stripping is sealing properly in all Inspect areas. Inspect weather stripping to insure it has not pulled out of the receiver channel. To reinstall it, all weather stripping to insure it has not pulled out of the receiver channel. To reinstall it, pullthe theweather-stripping weather-stripping completely completely out reinsert it byit sliding the spline into the channel. pull out of ofthe thechannel channelthen then reinsert by sliding the spline intoreceiver the receiver channel. Check for an even reveal (gap) between the sash and the frame. Check for an even reveal (gap) between the sash and the frame. 6.6 Once thethe window is plumb, level, andand square, install appropriate installation fastener typestypes at theat anchorage locations as Once window is plumb, level, square, install appropriate installation fastener the anchorage locations specified in the drawings included in this document. Ensure the fasteners are properly secured in relationship to the vinyl as specified in the drawings included in this document. Ensure the fasteners are properly secured in relationship to the surface, but DO OVER TIGHTEN THE SCREWS/TAPCON TYPE ANCHORS, as this could cause thecause frame the to bow. vinyl surface, but NOT DO NOT OVER TIGHTEN THE SCREWS/TAPCON TYPE ANCHORS, as this could frame to Recheck the sash for proper operation once the anchors have been installed. Place sealant in the hole and then install bow. Recheck the sash for proper operation once the anchors have been installed. Place sealant in the hole and then the anchor through the frame for retrofit applications. Once the screw tapcon anchor installediscorrectly, install the anchor through the frame for retrofit applications. Once theorscrew ortype tapcon typeisanchor installed place correctly, additional sealant over the screw fill the to hole theand installation with the holes caps provided place additional sealant over thetoscrew filland thecap hole cap theholes installation with thewhen capsnecessary. provided when necessary. 3 7. Finish off the exterior of the window. Attach the sill extender (if necessary) to the bottom of the sill and trim it to fit in the opening. Be careful not to cut the sill extender too tight to prevent deflection of the sill. Sill extender should not be used as support. Be sure to use the proper grade of sealant to seal the entire perimeter of the window. Do not leave any gaps where water or outside elements can penetrate into the home. Use common sense to complete the exterior. Seal all areas that are prone to air or water infiltration. Make certain that the weeps on the outside of the window are open and that water can drain from the sill and out of the weeps. 8. Remember: The homeowner is the final inspector. Clean the window well and remove all debris from the job site. Be sure the homeowner is familiar with the proper operation, features and documentation of the window. (For example, the Simonton NFRC Label & Limited Warranty) 9. The enclosed drawings specify by style and frame type the minimum required anchorage and appropriate placement and spacing. For new construction frames note that screws and nails can be substituted, please contact the Simonton Service Solutions Team for acceptable substitutions if needed. ([email protected] or call 800-746-6704 or fax 866-824-9757) 4 Retrofit Frame Detail • Geometric 5 6 Retrofit Frame Detail • Double Hung 7 8 Retrofit Frame Detail • Twin Double Hungs 9 10 Retrofit Frame Detail • Horizontal Roller 11 12 Retrofit Frame Detail • Awning 13 14 Retrofit Frame Detail • Casement 15 16 Retrofit Frame Detail • Twin Casements 17 18 Retrofit Frame Detail • Picture Window 19 20 New Construction Frame Detail • Double Hung 21 22 New Construction Frame Detail • Horizontal Roller 23 24 New Construction Frame Detail • Awning 25 26 New Construction Frame Detail • Casement 27 28 New Construction Frame Detail • Picture Window 29 STRM1210A / 0212 Publication No. 085114