KOFLO Static Mixers Flanged SS Data Sheet

Transcription

KOFLO Static Mixers Flanged SS Data Sheet
KOFLO Series 275 SS Flanged Static Mixer
"B" HOLES "C" DIAMETER
ON A "D" D.B.C.
"A"
(Inches)
KOFLO STATIC MIXER CONSTRUCTED OF
SCHEDULE 40 OR 10 PIPE WITH *____ FIXED
MIXING ELEMENTS
150 LB. RAISED FACE FLANGED ENDS
NOTE: SCH 40 IS USED FOR CARBON STEEL MIXERS
SCH 10 IS USED FOR SS/ALLOY MIXERS 3" AND LARGER
Koflo Corporation
309 CARY POINT DR.
CARY, IL 60013
SCALE:
DATE:
NONE
9/11/85
APPROVED BY
DRAWN BY
REVISED
NJF
12/10/93
5/22/08
CUSTOMER:
REVISED
MODEL NO:
DRAWING NUMBER:
REVISED
TYPICAL FLANGE MOUNTED MIXER
KD-1018
KOFLO Series 275 SS Flanged Static Mixer with Side Injection Port
"B" HOLES "C" DIAMETER
ON A "D" D.B.C.
"A"
(Inches)
"E"
FNPT INJECTION PORT
"F" SIZE OR AS SPECIFIED
DIRECTION
OF FLOW
KOFLO STATIC MIXER CONSTRUCTED OF
SCHEDULE 40 OR 10 PIPE WITH *____ FIXED
MIXING ELEMENTS
150 LB. RAISED FACE FLANGED ENDS
NOTE: SCH 40 IS USED FOR CARBON STEEL MIXERS
SCH 10 IS USED FOR SS/ALLOY MIXERS 3" AND LARGER
Koflo Corporation
309 CARY POINT DR.
CARY, IL 60013
SCALE:
DATE:
NONE
9/11/85
APPROVED BY
DRAWN BY
REVISED
NJF
3/22/00
5/29/08
CUSTOMER:
REVISED
MODEL NO:
DRAWING NUMBER:
REVISED
TYPICAL FLANGE MOUNTED MIXER
WITH FNPT INJECTION PORT
KD-1017
KOFLO Series 275 SS Flanged Static Mixer - Low Pressure Loss Design
"B" HOLES "C" DIAMETER
ON A "D" D.B.C.
"A"
(Inches)
KOFLO STATIC MIXER CONSTRUCTED OF
SCHEDULE 40 OR 10 PIPE WITH *____ FIXED
LOW PRESSURE LOSS DESIGN MIXING ELEMENTS
150 LB. RAISED FACE FLANGED ENDS
NOTE: SCH 40 IS USED FOR CARBON STEEL MIXERS
SCH 10 IS USED FOR SS/ALLOY MIXERS 3" AND LARGER
Koflo Corporation
309 CARY POINT DR.
CARY, IL 60013
SCALE:
DATE:
NONE
7/10/07
APPROVED BY
DRAWN BY
REVISED
NJF
5/30/08
CUSTOMER:
REVISED
MODEL NO:
DRAWING NUMBER:
REVISED
TYPICAL LOW PRESSURE LOSS DESIGN
FLANGE MOUNTED MIXER
KD-986
KOFLO Series 275 SS Flanged Static Mixer - Low Pressure Loss Design
with Side Port Injection
"B" HOLES "C" DIAMETER
ON A "D" D.B.C.
"A"
(Inches)
"E"
FNPT INJECTION PORT
"F" SIZE OR AS SPECIFIED
DIRECTION
OF FLOW
KOFLO STATIC MIXER CONSTRUCTED OF
SCHEDULE 40 OR 10 PIPE WITH *____ FIXED
LOW PRESSURE LOSS DESIGN MIXING ELEMENTS
150 LB. RAISED FACE FLANGED ENDS
NOTE: SCH 40 IS USED FOR CARBON STEEL MIXERS
SCH 10 IS USED FOR SS/ALLOY MIXERS 3" AND LARGER
Koflo Corporation
309 CARY POINT DR.
CARY, IL 60013
SCALE:
DATE:
NONE
7/10/06
APPROVED BY
DRAWN BY
REVISED
NJF
5/30/08
CUSTOMER:
REVISED
MODEL NO:
DRAWING NUMBER:
REVISED
TYPICAL LOW PRESSURE LOSS DESIGN FLANGE
MOUNTED MIXER WITH FNPT INJECTION PORT
KD-985