KOFLO Static Mixers Flanged SS Data Sheet
Transcription
KOFLO Static Mixers Flanged SS Data Sheet
KOFLO Series 275 SS Flanged Static Mixer "B" HOLES "C" DIAMETER ON A "D" D.B.C. "A" (Inches) KOFLO STATIC MIXER CONSTRUCTED OF SCHEDULE 40 OR 10 PIPE WITH *____ FIXED MIXING ELEMENTS 150 LB. RAISED FACE FLANGED ENDS NOTE: SCH 40 IS USED FOR CARBON STEEL MIXERS SCH 10 IS USED FOR SS/ALLOY MIXERS 3" AND LARGER Koflo Corporation 309 CARY POINT DR. CARY, IL 60013 SCALE: DATE: NONE 9/11/85 APPROVED BY DRAWN BY REVISED NJF 12/10/93 5/22/08 CUSTOMER: REVISED MODEL NO: DRAWING NUMBER: REVISED TYPICAL FLANGE MOUNTED MIXER KD-1018 KOFLO Series 275 SS Flanged Static Mixer with Side Injection Port "B" HOLES "C" DIAMETER ON A "D" D.B.C. "A" (Inches) "E" FNPT INJECTION PORT "F" SIZE OR AS SPECIFIED DIRECTION OF FLOW KOFLO STATIC MIXER CONSTRUCTED OF SCHEDULE 40 OR 10 PIPE WITH *____ FIXED MIXING ELEMENTS 150 LB. RAISED FACE FLANGED ENDS NOTE: SCH 40 IS USED FOR CARBON STEEL MIXERS SCH 10 IS USED FOR SS/ALLOY MIXERS 3" AND LARGER Koflo Corporation 309 CARY POINT DR. CARY, IL 60013 SCALE: DATE: NONE 9/11/85 APPROVED BY DRAWN BY REVISED NJF 3/22/00 5/29/08 CUSTOMER: REVISED MODEL NO: DRAWING NUMBER: REVISED TYPICAL FLANGE MOUNTED MIXER WITH FNPT INJECTION PORT KD-1017 KOFLO Series 275 SS Flanged Static Mixer - Low Pressure Loss Design "B" HOLES "C" DIAMETER ON A "D" D.B.C. "A" (Inches) KOFLO STATIC MIXER CONSTRUCTED OF SCHEDULE 40 OR 10 PIPE WITH *____ FIXED LOW PRESSURE LOSS DESIGN MIXING ELEMENTS 150 LB. RAISED FACE FLANGED ENDS NOTE: SCH 40 IS USED FOR CARBON STEEL MIXERS SCH 10 IS USED FOR SS/ALLOY MIXERS 3" AND LARGER Koflo Corporation 309 CARY POINT DR. CARY, IL 60013 SCALE: DATE: NONE 7/10/07 APPROVED BY DRAWN BY REVISED NJF 5/30/08 CUSTOMER: REVISED MODEL NO: DRAWING NUMBER: REVISED TYPICAL LOW PRESSURE LOSS DESIGN FLANGE MOUNTED MIXER KD-986 KOFLO Series 275 SS Flanged Static Mixer - Low Pressure Loss Design with Side Port Injection "B" HOLES "C" DIAMETER ON A "D" D.B.C. "A" (Inches) "E" FNPT INJECTION PORT "F" SIZE OR AS SPECIFIED DIRECTION OF FLOW KOFLO STATIC MIXER CONSTRUCTED OF SCHEDULE 40 OR 10 PIPE WITH *____ FIXED LOW PRESSURE LOSS DESIGN MIXING ELEMENTS 150 LB. RAISED FACE FLANGED ENDS NOTE: SCH 40 IS USED FOR CARBON STEEL MIXERS SCH 10 IS USED FOR SS/ALLOY MIXERS 3" AND LARGER Koflo Corporation 309 CARY POINT DR. CARY, IL 60013 SCALE: DATE: NONE 7/10/06 APPROVED BY DRAWN BY REVISED NJF 5/30/08 CUSTOMER: REVISED MODEL NO: DRAWING NUMBER: REVISED TYPICAL LOW PRESSURE LOSS DESIGN FLANGE MOUNTED MIXER WITH FNPT INJECTION PORT KD-985