CustomVue see a brochure in English

Transcription

CustomVue see a brochure in English
AMO Innovation At Every Step
The Advanced CustomVue™ Treatment Using VISX™ Technology
Is Essential To The iLASIK™ Solution
Millions of LASIK candidates have been waiting for the most advanced LASIK technology … They’ve
been waiting for the iLASIK procedure: AMO’s innovative combination of IntraLase™ technology with
the Advanced CustomVue treatment using VISX technology.
The iLASIK technology solution will help you grow your refractive practice by:
• Providing an integrated platform featuring advanced technology at every step
• Driving demand for the iLASIK procedure by actively targeting all segments of “Generation i”
• Giving physicians a committed partner that is making an unmatched investment in LASIK
Combined Advantages
One company, one integrated LASIK platform and one committed refractive partner — that’s how we
define the iLASIK solution. Our “forward-thinking” strategy, combining all the best LASIK technology,
delivers the potential for long-term clinical advantages and ergonomic improvements, while spelling
the end of the “a la carte” assemblage of system components in the laser suite.
The Pinnacle Of Innovation — VISX™ Technology
It’s Time To Meet “Generation i”
Increasing the success of your practice means increasing the overall size of the LASIK category. Growing
LASIK and growing your practice is the ultimate objective of the iLASIK solution. We’ll help you reach
out to “Generation i” — the dynamic group of prospects spanning Generation Y, Generation X and
Baby Boomers — by speaking their language and taking the mystery and confusion out of laser vision
correction. Your marketing conversation with consumers just got a whole lot easier — it begins with the
iLASIK procedure.
The “i” Changes Everything
References:
1. Data submitted to the FDA for the CustomVue High Myopia Study. Data on File.
2. Dai GM, Gross E, Liang J. System performance evaluation of refractive surgical lasers: a mathematical approach. Appl Opt. 2006;45(9):2124-34.
3. The Advanced CustomVue Monovision procedure clinical trial data. Data on file.
Advanced Medical Optics, Inc. • 3400 Central Expressway, Santa Clara, CA • 95051 USA • 1 [800] 246-VISX • 1 [408] 773-2020 • www.amo-ilasik.com
©2007 Advanced Medical Optics, Inc. All Rights Reserved. AMO, the AMO logo, iLASIK and the iLASIK logo are trademarks of Advanced Medical Optics, Inc.
Advanced CustomVue, the Advanced CustomVue logo, CustomVue, STAR S4 IR, the STAR S4 IR logo, Treat with Certainty, VISX, VRR, VSS, WaveScan, the WaveScan logo
and WaveScan WaveFront are trademarks of VISX, Incorporated. IntraLase is a trademark of IntraLase Corp. Mkt Doc 685 Rev. A
58503_Visx.2.indd 1
11/2/07 4:59:58 PM
The Most Advanced
WaveScan WaveFront™ System
Laser Vision Correction Technology Available Today*
Iris Registration automatically aligns the treatment plan to match the location of the
wavefront error when measured at the WaveScan WaveFront™ System.
The Advanced CustomVue™ procedure provides the broadest range of custom wavefront-guided
laser vision correction:
•
Myopia (with or without astigmatism)
•
High myopia (up to -11 D, with or without astigmatism)
•
Mixed astigmatism
•
Hyperopia (with or without astigmatism)
•
Monovision for presbyopic patients with low-to-moderate myopia, with or without astigmatism
“VISX™ Advanced CustomVue seems to be, in my hands at least, better
than other customized ablations, because Fourier versus Zernike
provides the higher resolution, and Iris Registration provides the perfect
match between the measured and the treated areas.”
— Prof. Dr. Michael C. Knorz
FreeVis LASIK Zentrum Universitätsklinikum Mannheim, Germany
Clearer Night Vision
Clinical studies for all indications submitted to the FDA showed higher participant satisfaction with
night vision after the Advanced CustomVue procedure than before with glasses or contact lenses.
Patient Satisfaction with Vision at Night1
CustomVue™ High Myopia
Preop BSCVA to Postop UCVA
*As determined by the Market Scope 2007 Annual Refractive Surgeon Survey.
58503_Visx.1.indd 2
11/2/07 7:29:03 AM
Treat With Certainty™
Variable Spot Scanning (VSS™) And
Variable Repetition Rate (VRR™) Technologies
VSS technology, available only from AMO, ensures the intricate shapes reconstructed
by the Fourier wavefront algorithm are precisely ablated.
VRR technology delivers proprietary algorithms that vary the laser’s
pulse rate. By continually changing the size and placement of the beam,
VRR technology provides:
•
The ability to deliver Fourier shapes with optimized ablation
time while ensuring minimal thermal impact on the cornea
•
More accurate reconstruction of wavefront profile and intricate ablation shapes
•
Faster treatment times
•
Smoother ablation profiles
Combined, VSS and VRR technologies:
•
Minimize thermal effects and optimize clinical results
•
Achieve the ideal treatment speed by mixing the pulse sizes,
distribution and repetition rate
•
Provide potentially better overall outcomes, including
night vision quality
STAR S4 IR™ Laser
VSS Simulation Results2
A new level of precision may be predictably achieved by linking the
advanced refractive information of the WaveScan WaveFront™ System
with the STAR S4 IR™ Excimer Laser System, providing accurate
alignment and centration for every patient.
Even the slightest shift between eye
alignment and treatment alignment
can prevent optimum outcomes.
58503_Visx.1.indd 3
•
Fourier technology captures approximately 240 data points
(over a 7 mm pupil) — 25-times more precise than standard
measurements for glasses or contact lenses
•
The Fourier algorithm delivers the highest resolution of the
wavefront error available today by utilizing 100% of the available
data to design the optimal treatment
•
Iris Registration (IR) uses multiple matching reference points
from the iris to capture and compensate for torsional angle,
as well as pupil centroid shift
•
IR provides greater alignment accuracy with sub-flap iris imaging
•
IR also allows for instant re-registration in the event of
intraoperative cyclotorsional movement
Fitting Error Comparison
This theoretical simulation of VSS and VRR technologies, when compared to the alternative
Small Spot Scanning (SSS) ablation, shows improved precision and accuracy, or decreased fitting
error, across the above ablation profiles.
11/2/07 7:29:31 AM
VISX™ Wavefront-guided LASIK for Correction of Myopic, Hyperopic, and Mixed Astigmatism and Wavefront-guided Monovision LASIK for Presbyopic Myopes (CustomVue™ LASIK Laser Treatment)
Building On A Legacy
Statements regarding the potential benefits of wavefront-guided LASIK (CustomVue) are based upon the results of clinical trials. These results are indicative of not only the CustomVue treatment but also the care of the clinical physicians, the control
of the surgical environment by those physicians, the clinical trials’ treatment parameters and the clinical trials’ patient inclusion and exclusion criteria. Although many clinical trial patients after the CustomVue procedure saw 20/20 or better and/or had
or reported having better vision during the day and at night, compared to their vision with glasses or contact lenses before the procedure, individual results may vary. You can find information about the clinical trials below and in the Professional Use
Information Manuals for the VISX STAR S4™ Excimer Laser System and WaveScan WaveFront™ System (CustomVue Treatments).
As with any surgical procedure, there are risks associated with the CustomVue treatment. Before treating patients with the CustomVue procedure, you should carefully review the Professional Use Information Manual, complete the Physician CustomVue
Certification Course, provide your patients with the Patient Information Booklet for CustomVue LASIK Laser Treatment, and discuss the risks associated with this procedure and questions about the procedure with your patients.
Of Innovation
WAVEFRONT-GUIDED LASIK INDICATIONS AND INTENDED USES:
The VISX STAR S4 Excimer Laser System and WaveScan WaveFront System are approved to perform wavefront-guided laser assisted in-situ keratomileusis (LASIK) treatments for the reduction or elimination of low to moderate myopic astigmatism up
to -6.00 D MRSE, with cylinder between 0.00 and -3.00 D in patients 21 years of age or older; and in patients with documented evidence of a change in manifest refraction of no more than 0.50 D (in both cylinder and sphere components) for at least
one year prior to the date of pre-operative examination.
Wavefront-guided LASIK for correction of low to moderate myopic astigmatism is an elective procedure with the alternatives including but not limited to eyeglasses, contact lenses, photorefractive keratectomy (PRK), conventional LASIK, and other
refractive surgeries. Approval of the low to moderate myopic astigmatism application is based on a clinical trial of 351 eyes (189 primary and 162 secondary). Of all eyes treated, 318 were evaluated for effectiveness with 98.8% accountability at 3
months, 277 eyes with 96.9% accountability at 6 months, 102 eyes with 95.3% accountability at 9 months, and 86 eyes with 95.6% accountability at 12 months. The studies found that of the 277 eyes eligible for the uncorrected visual acuity (UCVA)
analysis of effectiveness at 6 months, 100% were corrected to 20/40 or better, and 95.8% were corrected to 20/20 or better in 71 spherical myopia eyes; and 99.5% were corrected to 20/40 or better, and 93.2% were corrected to 20/20 or better in 206
astigmatic myopia eyes. The study showed that at the 3 month stability time point: there was a loss of ≥ 2 lines of best corrected vision that can be obtained with spectacles in 1 of 239 astigmatic myopia eyes and there was no loss of ≥ 2 lines of best
corrected vision in 79 spherical myopia eyes; there was 1 of 239 astigmatic myopia eyes with best spectacle corrected visual acuity (BSCVA) worse than 20/25 and none in 79 spherical myopia eyes with BSCVA worse than 20/25. During the course of
study, no eye lost >2 lines of BSCVA and no eye had a BSCVA worse than 20/40.
Monovision Treatment For Presbyopic Myopia Patients
The Advanced CustomVue™ procedure is the first and only FDA-approved wavefront-guided
monovision treatment to correct both near and distance vision in presbyopic patients with low-tomoderate myopia, with or without astigmatism.
At 12 months:
•
•
•
•
“We finally have the option to
provide presbyopic patients
with near vision correction
that matches the accuracy
and quality of vision we
routinely achieve for distance
correction. The Advanced
CustomVue Monovision
procedure sets a new standard
for visual outcomes and
patient satisfaction.”
99% of study participants achieved binocular near
UCVA of 20/25 or better
97% achieved binocular distance UCVA of 20/25 or better
86% of study participants achieved 20/20 or better for
both uncorrected near and uncorrected distance
visual acuity
98% of study participants expressed satisfaction with
their results
— Douglas D. Koch, MD
Baylor Vision
Texas, USA
Simultaneous UCDVA and UCNVA
90%
The VISX STAR S4 Excimer Laser System and WaveScan WaveFront System are approved to perform wavefront-guided laser assisted in-situ keratomileusis (LASIK) treatments for the reduction or elimination of hyperopic astigmatism up to 3.00 D
MRSE, with cylinder between 0.00 and 2.00 D in patients 21 years of age or older; and in patients with documented evidence of a change in manifest refraction of no more than 1.00 D (in both cylinder and sphere components) for at least one year prior
to the date of pre-operative examination.
Wavefront-guided LASIK for the correction of hyperopic astigmatism is an elective procedure with the alternatives including but not limited to eyeglasses, contact lenses, photorefractive keratectomy (PRK), conventional LASIK, and other refractive
surgeries. Approval of the hyperopic astigmatism application is based on a clinical trial of 144 eyes (74 primary and 70 secondary). Of all eyes treated, 134 were evaluated for effectiveness with 98.5% accountability at 3 months, 131 eyes with 97.0%
accountability at 6 months, 118 eyes with 90.8% accountability at 9 months, and 27 eyes with 87.1% accountability at 12 months. The studies found that of the 131 eyes eligible for the uncorrected visual acuity (UCVA) analysis of effectiveness at 6
months, 97.3% were corrected to 20/40 or better, and 66.2% were corrected to 20/20 or better in 74 spherical hyperopia eyes; and 93.0% were corrected to 20/40 or better, and 56.1% were corrected to 20/20 or better in 57 astigmatic hyperopia eyes.
The study showed that at the 6 month stability time point: there was no loss of ≥ 2 lines of best corrected vision that can be obtained with spectacles in either 63 astigmatic hyperopia eyes or 74 spherical hyperopia eyes; none of the 63 astigmatic hyperopia eyes or 74 spherical hyperopia eyes had best spectacle corrected visual acuity (BSCVA) worse than 20/25. During the course of study, one of 63 eyes with astigmatic hyperopia lost >2 lines of BSCVA at 1 month, no eyes with spherical hyperopia
lost >2 lines of BSCVA, and no eye had a BSCVA worse than 20/40.
The VISX STAR S4 IR™ Excimer Laser System with VSS™ Technology and WaveScan WaveFront™ System are approved to perform wavefront-guided laser assisted in-situ keratomileusis (LASIK) treatments for the reduction or elimination of naturally
occurring mixed astigmatism when the magnitude of cylinder (from 1.0 to 5.0 D) is greater than the magnitude of sphere and the cylinder and sphere have opposite signs; in patients 21 years of age or older; and in patients with documented evidence
of a change in manifest refraction of no more than 0.50 D (in both cylinder and sphere components) for at least one year prior to the date of pre-operative examination.
Wavefront-guided LASIK for the correction of mixed astigmatism is an elective procedure with the alternatives including but not limited to eyeglasses, contact lenses, photorefractive keratectomy (PRK), conventional LASIK, and other refractive
surgeries. Approval of the mixed astigmatism application is based on a clinical trial of 86 eyes. Of all eyes treated, 86 were evaluated for effectiveness with 100.0% accountability at 3 months, 80 eyes with 95.2% accountability at 6 months, 69 eyes
with 86.3% accountability at 9 months, and 63 eyes with 94.0% accountability at 12 months. The studies found that of the 86 eyes eligible for the uncorrected visual acuity (UCVA) analysis of effectiveness at 3 months, 95.3% were corrected to 20/40
or better, 91.9% were corrected to 20/32 or better, and 61.6% were corrected to 20/20 or better without spectacles or contact lenses. The study showed that of 86 astigmatic eyes, one eye temporarily lost 2 lines of best corrected vision that can be
obtained with spectacles at 1 month and at 6 months and none of the eyes had best spectacle corrected visual acuity (BSCVA) worse than 20/40.
The STAR S4 IR Excimer Laser System and WaveScan WaveFront System are approved to perform wavefront-guided laser assisted in-situ keratomileusis (LASIK) treatments to achieve monovision by the targeted retention of myopia (-1.25 to -2.00 D)
in the non-dominant eye of presbyopic myopes with myopic astigmatism up to -6.00 D MRSE, with cylinder between 0.00 and -3.00 D in patients 40 years of age or older; in patients with documented evidence of a change in manifest refraction of no
more than 0.50 D (in both cylinder and sphere components) for at least one year prior to the date of pre-operative examination and with a successful preoperative trial of monovision or history of monovision experience.
Wavefront-guided LASIK for monovision is an elective procedure with the alternatives including but not limited to bifocal, trifocal and progressive eyeglasses, contact lenses, or a combination of refractive surgery and reading glasses. Approval of the
monovision application is based on a clinical trial of 159 treated dominant eyes and 137 treated non-dominant eyes of 160 subjects. Of all subjects, 157 were evaluated for effectiveness with 98.1% accountability at 3 months, 158 subjects with 98.8%
accountability at 6 months, 152 subjects with 97.4% accountability at 9 months, and 149 eyes with 97.4% accountability at 12 months. The study found that at 6 months, 100% of subjects achieved binocular uncorrected distance visual acuity of 20/40
or better, and 86.7% achieved 20/20 or better. At 6 months 100% of subjects achieved binocular uncorrected near visual acuity of 20/40 or better, and 88.0% achieved 20/20 or better. At 6 months 100% of subject achieved simultaneous binocular
uncorrected distance and near visual acuity of 20/40 or better, and 79.7% achieved 20/20 or better. At 6 months 98.7% of subjects achieved binocular uncorrected intermediate visual acuity of 20/40 or better, and 84.8% achieved 20/20 or better. The
study showed that at 6 months no eyes lost 2 or more lines of best corrected distance vision that can be obtained with spectacles (BSCVA), and one eye (0.3%) lost 2 lines of best corrected near visual acuity. There were no eyes with best corrected
distance or near visual acuity worse than 20/25.
CONTRAINDICATIONS:
Wavefront-guided LASIK is contraindicated in patients with collagen vascular, autoimmune or immunodeficiency disease, signs of keratoconus or abnormal corneal topography, patients taking isotretinoin (Accutane®*) or amiodarone hydrochloride
(Cordarone® †) or are pregnant or nursing.
WARNINGS:
Wavefront-guided LASIK is not recommended in patients who have diabetes, a history of Herpes simplex or Herpes zoster keratitis, significant dry eye that is unresponsive to treatment, or severe allergies. For the treatment of low to moderate myopic
astigmatism, lower uncorrected visual acuity may be anticipated in the treatment of higher degrees of myopia with and without astigmatism (>-5.0 D MRSE).
20/20 or Better
20/25 or Better
Although the WaveScan WaveFront System measures the refractive error and wavefront aberrations of the human eyes, including myopia, hyperopia, astigmatism, coma, spherical aberration, trefoil, and other higher order aberrations through sixth
order, in the clinical studies for low to moderate myopic astigmatism, hyperopic astigmatism and mixed astigmatism, the average higher order aberration did not decrease after CustomVue treatment. In the clinical studies for high myopic astigmatism,
the average higher order aberration increased after CustomVue treatment.
20/40 or Better
It is possible, after wavefront-guided LASIK treatment, that patients will find it more difficult than usual to see in conditions such as very dim light, rain, snow, fog, or glare from bright lights at night. Visual performance possibly could be worsened by
large pupil sizes or decentered pupils. Pupil size should be evaluated under mesopic illumination conditions.
80%
The use of Percentage Nomogram Adjustment should be based upon careful consideration of patient and surgeon information, in addition to environmental conditions surrounding the surgery. The simultaneous use of the Percentage Nomogram Adjustment and the Physician Adjustment has not been studied in controlled investigations, and should not be attempted until the accuracy of the Nomogram setting has been verified for the same laser, treatment conditions and type of treatment. Therefore,
the combined simultaneous use of the Percentage Nomogram Adjustment and the Physician Adjustment is not recommended without careful analysis of postoperative refractive results.
70%
ADVERSE EVENTS AND COMPLICATIONS:
The clinical trial for low to moderate myopic astigmatism showed that the following adverse events or complications occurred in at least 1% of the 351 eyes at any interval up to 6 months post-treatment: inflammation of the cornea under the flap (1.4%);
double or ghost images (1.4%); and scratch on the surface of the eye (1.4%). The following subjective symptoms frequency rated “often or always” were increased in the effectiveness cohort at 6 months post-treatment on 258 eyes compared with
pre-treatment on 332 eyes: dryness (9% vs. 6%); fluctuation of vision (3% vs. 2%); glare (4% vs. 2%) and halos (7% vs. 5%).
60%
50%
The clinical trial for high myopic astigmatism showed that the following adverse events or complications occurred in at least 1% of the 184 eyes at one or more postoperative examinations up to 6 months post-treatment: epithelium in the interface
(1.1%); peripheral corneal epithelial defect at 1 month or later (2.2%); corneal edema between 1 week and 1 month post-operatively (2.7%) and double vision (or “ghost images”) in the operative eye (6.0%). The following subjective symptoms were
reported as present “often or always” by a higher percentage of subjects 6 months after treatment than before treatment: dryness (10.8% vs. 9.3%); halos (21.6% vs. 15.4%); and ghosting or shadowing of images (2.8% vs. 1.1%).
40%
The clinical trial for hyperopic astigmatism showed that the following adverse events or complications occurred in at least 1% of the 144 eyes at any interval up to 6 months post-treatment: cells growing under the flap (2.1%); feeling of something in
the eye (1.4%); double or ghost images (11.3%); and scratch on the surface of the eye (2.1%). The following subjective symptoms rated “often or always” were increased in the effectiveness cohort at 6 months post-treatment on 131 eyes compared
with pre-treatment on 136 eyes: dryness (17% vs. 6%); blurry vision (10% vs. 7%); fluctuation of vision (14% vs. 6%); halos (10% vs. 5%); double or ghost images (7% vs. 3%).
86% of study participants achieved
binocular simultaneous 20/20 or
better for both uncorrected near and
uncorrected distance visual acuity.
30%
20%
The clinical trial for mixed astigmatism showed that the following adverse events or complications occurred in at least 1% of the 86 eyes at one or more postoperative examinations up to 3 months post-treatment: miscreated flap (1.2%); cells growing
under the flap (4.7%); and double vision (or “ghost images”) in the operative eye (8.1%). The following subjective symptoms were reported as present “often or always” by a higher percentage of subjects 3 months after treatment than before treatment:
dryness (22% vs. 6%); halos (20% vs. 13%).
The clinical trial for monovision showed that the following adverse events or complications occurred in at least 1% of the 296 treated eyes of 160 subjects: diffuse lamellar keratitis (4.1% of eyes), epithelium in the interface (1.0% of eyes) and ghost
images or diplopia (17.5% of subjects). No subjects with diplopia reported the diplopia as occurring “often” or “always”. Ghost images were reported as occurring “often” by four subjects and “always” by one subject. The following subjective symptoms
were reported as present “often or always” by a higher percentage of subjects 6 months after treatment than before treatment: dryness (11% vs. 6%); glare (4% vs. 3%); halos (10% vs. 8%); and ghosting (4% vs. 2%).
VISX, WaveScan, CustomVue, STAR S4, STAR S4 IR, VSS, WaveScan WaveFront and the Advanced CustomVue logo are trademarks of VISX, Incorporated.
The AMO logo is a trademark of Advanced Medical Optics, Inc.
* Accutane® is a registered trademark of Hoffmann-La Roche Inc.
† Cordarone® is a registered trademark of Sanofi-Synthelabo, Inc.
10%
0%
© July 2007 Advanced Medical Optics, Inc.
Preop
58503_Visx.1.indd 4
Wavefront-guided LASIK for correction of high myopic astigmatism is an elective procedure with the alternatives including but not limited to eyeglasses, contact lenses, photorefractive keratectomy (PRK), conventional LASIK, and other refractive
surgeries. Approval of the application is based on a clinical trial of 184 eyes. Of all eyes treated, 180 were evaluated for effectiveness with 97.8% accountability at 3 months, 178 eyes with 96.7% accountability at 6 months, 170 eyes with 96.5% accountability at 9 months, and 107 eyes with 93.9% accountability at 12 months. The studies found that of the 178 eyes eligible for the uncorrected visual acuity (UCVA) analysis of effectiveness at 6 months, 98.3% were corrected to 20/40 or better,
97.2 % were corrected to 20/32 or better, and 84.3% were corrected to 20/20 or better without spectacles or contact lenses. The study showed that of 83 spherical and 101 astigmatic eyes, no eyes lost 2 or more lines of best corrected vision that can
be obtained with spectacles (BSCVA) and none of the eyes had BSCVA worse than 20/40.
PRECAUTIONS:
The safety and effectiveness of wavefront-guided LASIK surgery has ONLY been established with an optical zone of 6 mm and an ablation zone of 8 mm for myopic astigmatism, and an optical zone of 6 mm and an ablation zone of 9 mm for hyperopic
and mixed astigmatism. Long term risks of wavefront-guided LASIK beyond 12 months have not been studied. The safety and effectiveness of the STAR S4 Excimer Laser System have NOT been established for wavefront-guided treatment of low to
moderate myopic astigmatism in patients: whose WaveScan™ wavefront diameter is less than 6 mm, for treatments greater than 6 diopters of MRSE or with greater than 3 diopters of astigmatism and for retreatment with CustomVue LASIK. The safety
and effectiveness of the STAR S4 Excimer Laser System have NOT been established for wavefront-guided treatment of high myopic astigmatism in patients: whose WaveScan™ wavefront diameter is less than 5 mm, for treatments greater than -11
diopters of MRSE or with greater than 3 diopters of astigmatism. The safety and effectiveness of the STAR S4 Excimer Laser System have NOT been established for wavefront-guided treatment of hyperopic astigmatism in patients: whose WaveScan
wavefront diameter is less than 5 mm; for treatments greater than 3 diopters of MRSE or with greater than 2 diopters of astigmatism and for retreatment with CustomVue LASIK. The safety and effectiveness of the STAR S4 IR™ Excimer Laser System
have NOT been established for wavefront-guided treatment of mixed astigmatism in patients: whose WaveScan wavefront diameter is less than 5 mm, for treatments greater than 5 diopters or less than 1 diopter of astigmatism and for retreatment with
CustomVue LASIK.
Advanced CustomVue Monovision3
100%
The VISX STAR S4 IR™ Excimer Laser System with VSS™ Technology and WaveScan WaveFront System are approved to perform wavefront-guided laser assisted in-situ keratomileusis (LASIK) treatments for the reduction or elimination of high myopic
astigmatism from -6.00 D to -11.00 D MRSE, with cylinder between 0.00 and -3.00 D in patients 21 years of age or older; and in patients with documented evidence of a change in manifest refraction of no more than 1.00 D (in both cylinder and sphere
components) for at least one year prior to the date of pre-operative examination.
6 Months
12 Months
11/2/07 7:30:11 AM