Wavefront-guided LASIK:
Transcription
Wavefront-guided LASIK:
Wavefront-guided LASIK: a practical approach to diagnostic methodology and technique, indications for LASIK with the Allegretto Wave Instructional Course 57. Tuesday September 10th, 2:00-4:00 PM Faculty: Cummings A, Jankow M, Kezirian G, Machat J, Maus M, Mrochen M, Moore C, Seiler T, Kanellopoulos AJ www.brilliantvision.com Wavefront-guided LASIK Lessons from a 2 and 1/2 year experience ESCRS Munich 2003 A. John Kanellopoulos, MD Director, Laservision.gr Eye Institute, Athens, Greece Manhattan Eye, Ear and Throat Hospital, NY Associate Professor, NYU Medical School, NY www.brilliantvision.com My Background • • • • Harvard Medical School-Cornea Fellow Cornell University-Cornea Fellow Medical Director- TLC Laser Eye Centers Director of Refractive Surgery, NYU Medical School, NY • Laservision.gr Eye Institute, Athens, Greece • Over 11000 Lasik procedures www.brilliantvision.com Experience-Excimer Lasers • • • • • • • Summit- Apex plus VISX-S2 and S3 Lasersight Nidek Alcon-Ladarvision B&L: Technolas 217 Wavelight: Allegretto-Wave www.brilliantvision.com One of the initial LASIK cases, 1993 www.brilliantvision.com Common problem with standard LASIK: “goasting” (large pupils, de-centered/small diameter ablations etc) www.brilliantvision.com Effects of Corneal Curvature on Ablation Profile Round spot shape, even energy distribution, 96% energy absorption Elliptical spot shape, only 26% energy absorption per pulse Cornea The ALLEGRETTO Wave compensates for the reduced energy absorption in the periphery with more spots! Result: True, large optical zone and ability to create prolate cornea shape. www.brilliantvision.com Effects of Corneal Curvature on Ablation Profile Round spot shape, even energy distribution, 96% energy absorption Elliptical spot shape, only 26% energy absorption per pulse Cornea The ALLEGRETTO Wave compensates for the reduced energy absorption in the periphery with more spots! Result: True, large optical zone and ability to create prolate cornea shape. www.brilliantvision.com Prolate Ablation Prolate Cornea Shape Prolate Cornea Shape with the ALLEGRETTO Wave Oblate cornea shape with other refractive laser systems www.brilliantvision.com -7D myopia corrected in same pt • One eye (top) with the Allegretto-Wave • The other eye (bottom) with the Technolas 217z www.brilliantvision.com Our Allegeretto-Wave and M2 experience in “standard LASIK”: • 287 consecutive eyes, underwent LASIK for myopia or myopic astigmatism. • The Allegetto-Wave treats by a gaussian-profile flying-spot of 0.9mm, with 200Hz frequency and a 250Hz active eye-tracker. • We evaluated amount of myopia and astigmatism, pre- and post-operative: UCVA and BCVA, IOP, endothelial cell count and wavefront analysis by the Wavelight Tscherning aberrometer. www.brilliantvision.com Prolate or Wavefront-enhanced LASIK • Experience with the Allegretto • Monitor with Wavefront analyzer • Monitor with LCS (Vector vision) www.brilliantvision.com Results: (presented originally at the winter ESCRS meeting in Barcelona, Spain 2.2002) • Mean values: The mean pre-operative sphere was – 4.75 D (-1.00 to –12.50) and the cylinder –1.25 (-0.25 to –3.75) • UCVA improved from 20/200 to 20/25. At 3 months 87% of the eyes were 20/20, 47% 20/15 and 32% 20/10. 100% of eye were within +/- 1D at 3 months. www.brilliantvision.com Results 100 90 80 70 60 50 40 30 20 10 0 8/10 (20/25) 10/10 (20/20) 12/10 (20/16) 15/10 (20/13) Day 1 Month 1 Month 2 Month 3 www.brilliantvision.com Results: “standard”-prolate LASIK • Wavefront analysis showed a postoperative increase in coma of only 35% (mean coma of 6% pre-op to 9% post-op) • 37% of eyes gained at least 1 line of BCVA • No complications were noted in this limited group www.brilliantvision.com Pre- and Post-op Wave BCVA improved 10/10 to 12/10 www.brilliantvision.com Case example: Pre-op RE: +2.00 –7.00 x 167 and BCVA 6/10 3m post “standard” LASIK :+0.50 -0.50 x 19 UCVA 9/10 In topographic terms all of the cylinder corrected, of importance the effective ablation zone on topography is exactly the one planned with the laser: 6.5mm www.brilliantvision.com Same patient: Orbscan measurements: pre-op above and postop below www.brilliantvision.com Results in 520 consecutive cases myopic astigmatism www.brilliantvision.com Results in 105 consecutive cases Hyperopia and mixed astigmatism www.brilliantvision.com My Technique www.brilliantvision.com Placement of the M2 www.brilliantvision.com Microkeratome pass www.brilliantvision.com Folding of flap, even moisture on stromal bed www.brilliantvision.com Check parameters Intraoperative moistute eq www.brilliantvision.com Irrigation of flap and careful wipe www.brilliantvision.com 2’ observation interval Flap is evaluated with build-in slit-lamp www.brilliantvision.com My technique • 1 Drop of Alcaine • Betadine drape • Isolate eyelids with drape • Aspirating speculum • Lubricate blade and rotating parts with Alcaine!!! www.brilliantvision.com My technique • Careful check of lock • Alcaine during MK assembly on eye • Technician observes tubing • Avoid pt sqeeze www.brilliantvision.com My technique • “Taco” flap to minimize Dehydration • Even bed hydration very important www.brilliantvision.com My technique • Irrigation very important • “Squeeze” out excees fluid and Striae with moist Weck-cell • “milky” drop (predforte 1%) to delineate gutter width, centration and striae www.brilliantvision.com Why Wavefront? • • • • • Necessary tool in today’s refractive practice Large (usually light-colored) pupils High astigmatism Enhancements (decentrations) “Enhancing” monovision www.brilliantvision.com Our Wavefront-guided experience started with a pilot study: • 10 patients • One eye wavefront-guided, the other “standard” LASIK • Wave group: RMSh pre-op 0.120.35 (0.17), post-op dropped to: 0.11. A reduction therefore of HOA • Non-wave: pre-op 0.165 post-op: 0.195 a slight increase of HOA just as in our larger standard LASIK group reported www.brilliantvision.com Purpose of Study • To evaluate the safety, efficacy and accuracy of wavefront-guided LASIK • To determine the spherical nomogram adjustment • To evaluate the wavefront pre- and postoperatively www.brilliantvision.com Key specifications that are important for the clinician: • - the frequency of the flying spot treatment is 200 Hz • - the spot size is 0.9 mm; • - its active eye-tracking system involves an infrared camera and three individual illumination modules to sense the eye movement (by fixing on the pupilary reflex) with a detection frequency of 250 Hz and a reaction time 6 to 8 msec www.brilliantvision.com Method • • • • • • 155 consecutive cases treated Refractive errors: -0.52 to -6.75 D Average refraction: -3.80 D Astigmatism: 0.00 to -3.75 D Average astigmatism: -0.85 D Average age: 29.5 yrs www.brilliantvision.com Method • WaveFront evaluated prior to surgery (4 scans) • Dilated pupil to 7mm (not cycloplegic, 1 drop Mydriacyl 1%)) • Pre-op, Day 1, Week 1, month 1 and Month 3 Data www.brilliantvision.com Wavefront-guided www.brilliantvision.com INPUT OUTPUT WaveLight Laser Technologie AG 10/2000 WaveAnalyzer Measurement Measurement Principle Principle Data Data Flow Flow INPUT Optical Ocular Aberrations Measurement of local distortions Local distortions Calculation of Wavefront Error WaveLight Laser Technologie AG 10/2000 Calculation of Ablation Profile Custom LASIK WaveAnalyzer OUTPUT WaveFront WaveFront basics basics HartmannShackSensor TscherningSensor + well-known technique + variable incoming pattern + central cornea information + patient sees own aberrations - expensive sensor - expensive low light sensor - incoming light must be diffraction limited - - insensitive of opacities WaveLight Laser Technologie AG sensitive against scattering - no central cornea information www.brilliantvision.com Laser, λ=532nm Laser Laser Lens AL M Mask INPUT IR-Led IR-LED CO Telescope S Shutter IR-Camera OL1 Lens Aperture stop C2 C1 Fixation target OUTPUT VIS-High-Sensitive-Camera WaveLight Laser Technologie AG 11/2001 OL2 Lens ALLEGRETTO WAVE WaveFront WaveFront basics basics THE ALLEGRETTO WAVE ANALYZER TS-Sensor Opacity Unsafe and misleading It appears that even opaque eyes can be measured because a clear image is seen on the instrument display But it is really caused by reflections of the lens. WaveLight Laser Technologie AG 11/2001 ALLEGRETTO WAVE HS Sensor Safe, only valid images can be processed The individual beams are distracted by the Opacity. No clear image can be seen, low risk of accidentially treating with wrong data By Thomas Zieger WaveLight Laser Technologie AG Ten top pearls of my technique • Wavefront monitoring essential for refractive surgery • Pt expectations • Understand the technology (surgeon-staff) • Aberration indices that REALLY matter • Preoperative measurements RE • Preoperative planning mesopic-scotopic pupil • Preoperative wave evaluation #, quality • Wavefront-guided OZ • Preoperative LASIK planning • Consistent flap, tracker, excimer energy www.brilliantvision.com Importance of capture www.brilliantvision.com Methods Tserning aberrometer, M2 and M2single use 130 and 110 heads www.brilliantvision.com Results: • Able to include 142 cases • Mean values: The mean pre-operative sphere was – 4.85 D (-1.00 to –6.50) and the cylinder –1.25 (0.25 to –2.75) • UCVA improved from 20/200 to 20/18. At 3 months 92% of the eyes were 20/20, 57% 20/15 and 34% 20/10. 100% of eye were within +/- 0.5D at 3 months. www.brilliantvision.com Results: Efficacy 15 13 11 10,5 11,5 10,5 11,6 10,5 11,6 9 Pre-op BCVA Post-op UCVA 7 5 3 1 -1 Day 1 Week 4 Month 3 www.brilliantvision.com Results: Safety 70 60 50 Loss of > 1 line Loss of 1 line No change Gained 1 or more lines Gained 2 or more lines 40 30 20 10 0 Day 1 Week 4 Month 3 www.brilliantvision.com Results Day 1: Programmed vs. Achieved 1 0 -8 -6 -4 -2 -1 0 -2 -3 -4 -5 -6 -7 -8 www.brilliantvision.com Programmed Achieved 0.5 DS Over 0.5 DS Under Linear (Achieved) Management of decentered ablation with the use of wavefront-guided LASIK A. John Kanellopoulos, MD Laservision.gr Eye Institute, Athens, Greece Manhattan Eye, Ear and Throat Hospital, NY Michael Mrochen, PhD- Un. Of Zurich www.brilliantvision.com Ablation decentration • Troublesome compl. c serious visually debilitating sideeffects.1, 9, 10 Causes: • Intra-op fixation error and/or drift of the patients’ fixation; • Ecc.-displaced treatment (surgeon error or equipment calibration error; and eye tracker or eye tracker calibration error2). • Larger decentrations are usually associated with larger reductions in low contrast sensitivity and visual acuity. 3 • Mrochen M, Krueger RR, Bueeler M, Seiler T. Aberration-sensing and wavefront-guided laser in situ keratomileusis management of decentered ablation. J Refract Surg 2002; Jul-Aug, 18(4)418-29. www.brilliantvision.com Verdon-W; Bullimore-M; Maloney-RK Visual performance after photorefractive keratectomy: A prospective study Arch-of-Ophthalmol 1996;(114/12):1465-1472 www.brilliantvision.com Treatment Centration • Centration = important bias in measmnts as well as reference points in laser treatments. • The actual clinical measmnts of wavefront, are centered by the coaxially cited corneal reflex, the geometrical center of the cornea, the corneal apex, and the entrance pupil, which is the actual point where the visual axis goes through. • There are several the potential biases of decentration of the human eye www.brilliantvision.com www.brilliantvision.com Centration errors sytematic and random Systematic: a constant decentration systematic caused by different axes (coordinate systems defined in measurement and treatment, or the defined axis where the coordinate system is not stable, the eye tracker is calibrated imprecisely, there is head tilt, or the initial alignment by the operator is not precise, or there is a fixation problem from the patient). www.brilliantvision.com Centration errors Systematic centration errors can be avoided with precise alignment techniques. Random or dynamic centration errors are avoided only with active eye tracking. Random or dynamic centration errors, which cause “smearing” of the ablation. www.brilliantvision.com Active tracking • A small pilot study compared the advantage of active eye tracking. Twenty eyes treated with eye tracking and 20 eyes treated without eye tracking were evaluated with regard to their wavefront indices. • There was difference in wavefront measurements in trefoil, quadrafoil, higher order astigmatism, and spherical aberrations. • Less stat. significant aberrations with the tracker-treated patients. This study confirms others that show eye tracking appears to improve the visual outcome of refractive surgery. www.brilliantvision.com Advantage of active eye tracking in refractive surgery U UniversitätsSpital Zürich • 20 eyes treated with eye-tracker • 20 eyes treated without eye-tracker Tracker group Non-tracker group Absolute value [µm] 0.12 0.10 0.08 Preoperative higher-order wavefront deviations in both examined groups 0.06 0.04 0.02 0.00 3-fol d com a 4-fol d s high . ord pher. ab . ast err. . On the importance of centration Mrochen-M; Eldeine-MS; Kaemmerer-M; Seiler-T; Hutz-W Improvement in photorefractive corneal laser surgery results using an active eye-tracking system .J Cataract-and-Refractive-Surgery. 2001; 27/7 (1000www.brilliantvision.com 1006) Methods • We define the decentration zone by obtaining the difference between the pre- and postoperative corneal topographic measurements, which is a tangential map. • The ablation is surrounded by a region of approximately zero power, determined with this method described by Mrochen.2 • The decentration of the ablation is determined as a distance of the center of the flattened zone from the center of the pupil. www.brilliantvision.com Methods • We term an ablation grossly decentered if this decentration is more than 1 mm • There is evidence that decentration, even as much as 100 microns, will significantly increased higher aberrations and the possibility of the symptoms described previously to affect the patients’ visual quality3 www.brilliantvision.com Treatment • We treat decentered ablations with a preop evaluation using wavefront measurements and topographic measurements of the decentered ablation. • The preoperative measurements include visual acuity, topography, OrbScan measurement as mentioned previously, and wavefront measurement. • low contrast sensitivity measured by the Vector Vision 3000 device www.brilliantvision.com Treatment • The wavefront-guided treatment is relatively standard. • Only one drop of Alcaine (proparacaine 0.5%, Allergan, Irvine, CA) as a topical anesthetic. • We instill a drop of ofloxacin (Ocuflox, Allergan, Irvine, CA) mixed with preservative-free Acular as antibiotic prophylaxis several times during flap repositioning, and a drop of PredForte.. (Fig. 6) www.brilliantvision.com • We use PredForte to delineate the flap gutter and ascertain good centration of the repositioned flap. • Any differences in the gutter width, either on the X or Y axis, even if the corneal markings are perfectly aligned, indicates a decentration of the flap, which requires repositioning. www.brilliantvision.com Results • The 3 patients were followed the first day, first week, first month, and then at three month intervals. • The initial group of patients have subjectively improved symptoms including night driving and quality of night vision. • All symptoms of monocular diplopia, ghosting and most of the glare subsided after this treatment. www.brilliantvision.com The pre-op and post-p corneal topography, www.brilliantvision.com The pre-op and post-p wavefront map www.brilliantvision.com Conclusion • In this small group we achieved significant improvement, both in the signs and symptoms of decentered LASIK. • Obvious limitations the relative corneal thickness and our ability to perform an enhancement. • Extreme decentrations, refractive errors, and higher order aberrations may exceed the limits that this technology can measure precisely. • Other methods to treat aberrated eyes are currently under study in the U.S.11 www.brilliantvision.com Conclusion • There is also promising work being done in determining the specific Zernike polynomials in higher order aberrations are important functionally in humans. • Better knowledge of the clinical correlation of these findings may help us create more effective customized enhancements.12,13 Further studies and clinical experience will enhance our understanding of most effective and safe methods to retreat aberrated eyes. • • Applegate, RA, Sarver EJ, Khemsara V. Are all aberrations Equal? J Refract Surg 2002. 18:S556-562. Applegate, RA, Ballentine C, Gross H, et al. Visual acuity as a function of Zernike Mode and Level of RMS Error, Optom and Vis Sci, in press. www.brilliantvision.com Wavefront-guided anhancements • Now 100% of our attempted enhancements • Since flap is created already, little new aberrations expected • Ability to treat decentrations and night vision problems • Unhappy eye study with Wavelight www.brilliantvision.com Unhappy eye study with Wavelight Methods:26 consecutive eyes that had LASIK and were symptomatic, underwent wavefront-guided treatment, based on 4 reproducible aberration measurements. We evaluated pre, and post-operative refraction, total and high order aberrations (RMSH), cornea and flap thickness, low contrast sensitivity (LCS) and possible complications. Follow-up was 3-7 months (4.5) Results: 22 eyes were included. The mean values were: refractive error: sphere: –0,92D (plano to –1.50) and cylinder: -0.85D (0 to –1,75). UCVA improved from 20/25 to 20/18. There was no loss of BCVA in any case. The RMSH decreased from 0.62 to 0.25. LCS improved by 55%. www.brilliantvision.com Sample study cases • • • • • • • 45 y/o male s/p LASIK for -5 OD : plano, BCVA 20/25+, LCS C4 OS: -0.50, BCVA 20/25+ LCS C5 WG enhancement OU, 6.5mm OZ Post-op: OD UCVA 20/20, LCS C6 OS UCVA 20/20, LCS C5 www.brilliantvision.com Pre and post-op data www.brilliantvision.com www.brilliantvision.com Sample case • • • • • • 28y/oF LASIK for -7 OD UCVA 20/25, -0,75-1,00 15 C4 OS UCVA 20/15 plano C6 WG enhancement OD, 6,5mmOZ Post-op UCVA 20/15, C6 www.brilliantvision.com www.brilliantvision.com Case 5 • Old LASIK when 20y/o • Did well for 2 years then developed KCN picture • Management with INTACS-very happy but large fluctuations of sphere (-2 to –8) • Removed intacs placed ALTK sliver 120 microns • Enhancement at 2 ms for -2.50-3.50 X 165 • 3 months post-op: 20/20 www.brilliantvision.com QuickTime™ and a DV - PAL decompressor are needed to see this picture. www.brilliantvision.com Post-LASIK ectasia • Minimal stroma: 280 • Minimal total K: 420 • Beware that microkeratome may become unstable (usually they cut thinner though) • Best treatment careful screening www.brilliantvision.com Conclusion • WaveFront-guided LASIK with the ALLEGRETTO-WAVE (a 0.9mm flying-spot and 200Hz) and the M2 appears to be safe and very effective for correction of myopic astigmatism • It has demonstarted in our clinical practice the ability to significantly reduce higher order aberrations www.brilliantvision.com Conclusion • Improving the quality of vision (Contrast sensitivity) • The postoperative results at day one were very impressive, possibly deriving from the smooth ablation pattern of corneal stroma bed and/or the smooth microkeratome pass. • Very significant improvement in BCVA postoperatively www.brilliantvision.com Thank You www.brilliantvision.com