Untitled - Lightworks

Transcription

Untitled - Lightworks
OmniTronix Specification Sheet for Model(s):
FL2T18-36M and FX2T18-36M
Description: Micro Controlled, MultiWatt, Wide Input Voltage Range, HF-Electronic Ballast
This Ballast will operate the following Lamps: F18T8, F30T8, F36T8, TC-L18W, TC-L24W, TC-L36W, TC-L40W, TC-F24W, TC-F36W,
T5c 22W, T5c 40W, F24T5, F39T5, TC-D/TC-T26W, TC-T32W, TC-T42W, and TC-T57W
Electrical Data (for 230V Application)
Input Voltage: 120V ±10% @ 50-60Hz
Lamp Wattage / Type
Input Wattage
Line Current mA
Power Factor
Ballast Factor
Efficiency Factor
THD %A
Current Crest Factor
F18T8
19.8
92
0.92
0.95
0.87
19
1.48
F30T8
-
F36T8
34
154
0.95
0.90
0.95
15
1.4
1 Lamp
TC-L18
17.9
85
0.91
0.83
0.82
20
1.4
TC-L24
25.2
116
0.94
0.93
0.90
17
1.4
TC-L36
33.3
150
0.96
0.86
0.93
15
1.4
F24T5
23.6
110
0.94
0.87
0.89
17
1.48
F39T5
38.7
172
0.96
0.92
0.93
13
1.4
T5c22
23
110
0.94
0.96
0.90
18
1.4
Lamp Wattage / Type
Input Wattage
Line Current mA
Power Factor
Ballast Factor
Efficiency Factor
THD %A
Current Crest Factor
F18T8
38
179
0.95
0.95
0.94
15
1.4
F30T8
-
F36T8
65
288
0.98
0.88
0.95
9.5
1.3
2 Lamps
TC-L18
33.5
151
0.96
0.84
0.90
15
1.4
TC-L24
50.1
231
0.97
0.93
0.90
12
1.4
TC-L36
62.4
275
0.98
0.85
0.96
9.6
1.4
F24T5
46
204
0.97
0.83
0.90
12
1.49
F39T5
70
310
0.98
0.86
0.95
9.2
1.3
T5c22
46
221
0.95
0.96
0.90
10
1.4
EM / RFI Compliance
Sound Rating
Ballast Type
Immunity
Input / Protection
Output / Protection
Min. Starting Temp.
Max. Case Temp.
Energy Star / E.E. Class
Approvals / Class
EN50147-1, EN61000-3-2, FCC Part 18-A
ā€œAā€
Digital Preheat Rapid Start (Warmstart)
EN61547, ANSI C8211-1993
Electronic Fuse
YES, Short and Open Circuit
-25°C (0°F) *See note on reverse side
+75°C (167F)
-- / Energy Efficiency Class A2
CSAus, cULus, UL listed, ENEC05, CE, Class ā€œPā€, 1 Outdoor
Wiring Diagram
Note:
Ballast case ground terminal must be grounded
Use only within an electrical enclosure
TYPE 1 OUTDOOR CLASS P
OmniTronix Engineering extends limited warranty only to the original purchaser or to the first user for the period of 3 years from date of manufacture as indicated by the date
code stamped on each product and when properly installed and under normal conditions of use. Due to a program of continuous improvement, OmniTronix Engineering
reserves the right to make any variation in design or construction to the equipment described. Data is based on tests performed by OmniTronix Engineering in a controlled
environment and representative of relative performance. Actual performance may vary depending on operating conditions.

Similar documents