PFC Corofil Firestop Compound
Transcription
PFC Corofil Firestop Compound
SERVICE PENETRATIONS Certificate number: FS453/04 P12 37 / P12 340 LUL PRODUCT REGISTRATION NUMBER: 355 PFC Corofil Firestop Compound Application Description PFC Corofil Firestop Compound is used to provide a PFC Corofil Firestop Compound is a specially fire rated seal around service penetrations in fire rated formulated gypsum based mortar, which is mixed with walls with water to be trowelled or poured around service BS 476:Part 22, PFC Corofil Firestop Compound penetrations. Plastic pipework must be protected with provides up to 6 hours fire protection. either PFC Corofil Firestop Collars or Intumescent and floors. Tested in accordance FIRE RATINGS Tested to BS 476:Part 22 0 3hr 6hr Pipe Wraps (see technical data sheets). General benefits: Fire Rating Smoke seal In floors, depending on the hole size, PFC Corofil Good acoustic insulation permanent shuttering panel (50mm) is cut and friction Simple installation fitted between services and the edges of the floor Load bearing seal for maintenance and light foot traffic slab. Firestop Compound is then trowelled over the Suitable for making good around most types of shuttering to a depth of 25mm thick and is allowed to service penetrations harden. The Firestop Compound is then mixed to a Unaffected by humidity pouring grade and tops the seal up to the required Maintenance free depth. No smoke emission Approved for use on London Underground projects consistency for trowelling into smaller openings. In larger openings, Firestop Compound may be cast into Fire Rating blocks which are built into walls. Fire Rating Thickness of Compound 1-2 Hours 75mm 3-6 Hours 100mm Acoustic Thickness of Compound In walls, Firestop Compound is mixed into a stiff Weighted Sound Coverage Thickness of Compound Number of Bags per m² 75mm 3.15 100mm 4.2 150mm 6.3 Reduction Index (Rw) 50mm 39dB 100mm 46dB 150mm 51dB London Underground (LUL) Testing LUL testing table as per LUL sealant results as follows: These are approximate calculations based on 22kg bags. The coverage does not take into account the percentage of the hole filled with services. Specification Install PFC Corofil Firestop Compound to provide up Smoke Density Ao (max) = 0.00 to 6 hours fire protection to all service penetrations Toxicity Tests R(max) = <0.01 through fire rated walls and floors. Installation to be Limiting Oxygen Index Value >30% LUL Product Registration Number 355 fully in accordance with manufacturer’s instructions. TECHNICAL INFORMATION Available from our technical sales office: Material Safety Data Sheets Installation Instructions Product Certification SERVICE PENETRATIONS PFC Corofil Firestop Compound ORDERING Load Bearing Fire Seals Thickness of Compound Minimum span of hole in floor 75mm Any length x 500mm* 100mm Any length x 750mm* Please provide the following information: Size of opening Details of service penetrations The open area free of services, thickness of seal Fire rating ratios for non-reinforced seals given above, allow an Quantity required ample safety margin for normal foot traffic e.g. loads of two men plus equipment with a combined weight of Please order from our technical up to 200kg. Firestop Compound sets in 30-45 PFC Corofil Firestop Compound poured onto permanent minutes and is capable of accommodating foot traffic mineral fibre shuttering in floor around service penetrations. sales office. PFC Corofil in approximately 72 hours. Units 3-4 King George Trading Estate * As a further safety margin, all floor seals with spans Davis Road greater than those shown in the table must be Chessington reinforced. Please contact our technical sales office Surrey KT9 1TT for details. Tel: + 44 (0) 208 391 0533 Fax: +44 (0) 208 391 2723 Email: [email protected] www.pfc-corofil.com PFC Corofil Firestop Compound trowelled into blockwork wall around service penetrations.