TENANT FIT OUT 2400 BULL STREET, SAVANNAH, GA . 31401.

Transcription

TENANT FIT OUT 2400 BULL STREET, SAVANNAH, GA . 31401.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
SAVE-A-LOT FOOD STORES
18.
19.
20.
TENANT FIT OUT
2400 BULL STREET,
SAVANNAH, GA . 31401.
DATE:
C "COMPANY NAME" 2010 ALL RIGHTS RESERVED
5.
DESCRIPTION:
4.
REV. NUMBER:
2.
3.
PREMISES ARE TO BE FREE FROM ASBESTOS AND OTHER HAZARDOUS SUBSTANCES AND GASES,
ANY SUCH ASBESTOS AND OTHER HAZARDOUS SUBSTANCES AND GASES SHALL BE REMOVED
(ACCORDING TO ALL APPLICABLE LAWS) PRIOR TO THE START OF WORK.
LANDLORD DELIVERING BUILDING AS-IS. ALL WORK BY SAVE-A-LOT GENERAL CONTRACTOR.
DURING THE BIDDING PERIOD, EACH CONTRACTOR SHALL BE HELD RESPONSIBLE TO VISIT THE
SITE AND VICINITY TO ACQUAINT THEMSELVES WITH THE EXISTING CONDITIONS, FACILITIES AND
OBSTRUCTIONS INVOLVED IN AND EXPECTED BY THE WORK INDICATED BY ALL CONTRACT
DOCUMENTS IN ORDER TO PROVIDE A COMPLETE AND ACCURATE BID. CONTRACTOR'S FAILURE TO
REASONABLY DETERMINE AND/OR ANTICIPATE THE EFFECT OF EXISTING CONDITIONS AND
INVOLVEMENT SHALL NOT BE JUSTIFICATION FOR ADDITIONAL COMPENSATION. PROVIDE" MEANS
"FURNISH AND INSTALL."
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OR SAVE-A-LOT
PROJECT MANAGER OF DISCREPANCIES. CONTRACTOR HAS SOLE RESPONSIBILITY OF FIELD
VERIFYING DIMENSIONS PRIOR TO ORDERING MATERIALS.
CONTRACTOR TO COORDINATE NEW SCOPE OF WORK REQUIREMENTS W/ ALL DISCIPLINES WITHIN
THIS SET OF DRAWINGS. CONTRACTOR TO INVESTIGATE EXISTING CONDITIONS THOROUGHLY AND
IDENTIFY CONFLICTS, IF ANY, AS EARLY AS POSSIBLE DURING CONSTRUCTION IN ORDER TO
RESOLVE CONFLICTS AS QUICKLY AS POSSIBLE
NOTIFY PROJECT MANAGER OF ANY STRUCTURAL DEFECTS OR CONDITIONS WITHIN THE LEASED
PREMISES IF DISCOVERED DURING THE BUILD-OUT OF THE LEASED PREMISES.
CONTRACTOR SHALL PROVIDE NECESSARY BARRIERS TO CONTAIN DUST / DEBRIS DURING
CONSTRUCTION. CONTRACTOR SHALL REMOVE DEBRIS FROM WORK AREA EACH DAY PRIOR TO
LEAVING SITE. CONTRACTOR SHALL PROVIDE FINAL CLEANING OF STORE AT END OF
CONSTRUCTION. INCLUDING, BUT NOT LIMITED TO, SALES AREA, OFFICE, BREAK ROOM, REST
ROOMS, BACK ROOM AREAS, COOLERS, FREEZERS, STORE FRONT GLAZING AND DOORS.
PROVIDE DUST PARTITION TO PROTECT EQUIPMENT AND ADJACENT, NON-WORK AREAS
USE ELECTRIC OR PNEUMATIC POWERED EQUIPMENT FOR INTERIOR WORK. DO NOT USE
EQUIPMENT THAT PRODUCES EXHAUST FUMES.
ALL WOOD, WOOD FRAMING AND WOOD BLOCKING NECESSARY FOR PLUMBING FIXTURES, TOILET
ACCESSORIES, TIME-CLOCK, SHELVING, DOOR STOPS, ETC. SHALL BE FIRE RETARDANT WOOD.
CONTRACTOR SHALL REMOVE / REPLACE OR USE A FIRE RETARDANT COATING APPLICATION (SUCH
AS FLAMEX FS-II) ON ALL NON FIRE-RETARDANT WOOD EXPOSED DURING CONSTRUCTION.
VISUALLY INSPECT THE ROOF FOR DAMAGE OR NEED OF REPAIR PRIOR TO BEGINNING ANY WORK
ON THE ROOF. IDENTIFY AND PHOTOGRAPH ANY EXISTING DAMAGE OR PROBLEM AREAS, AND
REPORT TO SAVE-A-LOT PROJECT MANAGER.
CONTRACTOR SHALL PROVIDE NECESSARY CUTTING AND PATCHING AT ALL PENETRATIONS FOR
PLUMBING, HVAC AND ROOF HATCH. IN ORDER TO PRESERVE THE ROOFING WARRANTY, THE
CONTRACTOR THAT INSTALLED THE ROOF SHOULD PERFORM THE WORK. OTHERWISE, HAVE THE
WORK PERFORMED BY A LICENSED ROOFING CONTRACTOR THAT IS APPROVED BY BOTH THE
ROOFING MANUFACTURER AND THE LANDLORD.
CONTRACTOR SHALL PROVIDE ALL ROOF PENETRATIONS PER NEW REFRIGERATION EQUIPMENT AND
ASSOCIATED STRUCTURAL, MECHANICAL AND ELECTRICAL PER MANUFACTURER'S SPECIFICATIONS.
SEE DETAILS 15 & 16 / A-4.
CONTRACTOR SHALL REPAIR ALL ROOF DAMAGE CAUSED BY EQUIPMENT INSTALLATION, REMOVAL
OR RELOCATION. CONTRACTOR SHALL REMOVE ALL DEBRIS FROM ROOF.
CONTRACTOR SHALL PROVIDE A SMOOTH, CLEAN AND LEVEL EXISTING CONCRETE FLOOR READY
FOR INSTALLATION OF NEW FLOOR FINISHES
COOLERS AND FREEZERS ARE FURNISHED N.I.C. AND INSTALLED BY REFRIGERATION CONTRACTOR.
CONTRACTOR SHALL COORDINATE REFRIGERATED CASE LOCATIONS w/ SAVE-A-LOT PROJECT
MANAGER AND REFRIGERATION DRAWINGS - TYPICAL.
CONTRACTOR SHALL PROVIDE AN AS-BUILT, RECORD SET OF DRAWINGS TO SAVE-A-LOT PROJECT
MANAGER AT PROJECT COMPLETION. ONE FULL SIZE SET & FULL SET OF PDF FILES ON CD.
CERTIFICATION:
1.
BY:
GENERAL NOTES
SHEET INDEX
SHT. NO.
DESCRIPTION
CS-1
COVER SHEET
F-1
FIXTURE PLAN - (FOR REFERENCE ONLY)
ARCHITECTURAL DRAWINGS
A-0
DEMOLITION PLAN
A-1
FLOOR PLAN
A-2
REFLECTED CEILING PLAN
A-3
ENLARGED FLOOR PLANS AND EXTERIOR ELEVATION
A-4.1
DETAILS
A-4.2
DETAILS
A-5
MECHANICAL CODE:
2006 INTERNATIONAL MECHANICAL CODE WITH GA AMENDMENTS.
2006 INTERNATIONAL FUEL GAS CODE WITH GA AMENDMENTS.
ELECTRICAL CODE:
2011 NATIONAL ELECTRICAL CODE WITH GA AMENDMENTS.
FIRE CODE:
2006 INTERNATIONAL FIRE CODE AND OCGA 120-3-3.
ACCESSIBILITY:
1997 GA ACCESSIBILITY STANDARDS.
ENERGY CODE :
2009 INTERNATIONAL ENERGY CONSERVATION CODE WITH GA AMENDMENTS.
LIFE SAFETY CODE :
2000 NFPA 101 AND OCGA 120-3-3.
CONSTRUCTION CLASSIFICATION: --------------------------------5B
USE GROUP: ----------------------------------M-MERCANTILE EXISTING SINGLE STORY- NO CHANGE
AREA CALCULATIONS:
GROUND FLOOR: ------------------------------------------------------------------------17,120 SF
NORTH
PROJECT DESCRIPTION
THIS PROJECT IS A TENANT FIT-OUT / REMODEL OF A PORTION OF A
FORMER RETAIL BUILDING. THE WORK WILL INCLUDE INTERIOR FIXTURE
/ EQUIPMENT MODIFICATIONS / INSTALLATIONS AFTER SUB-DIVIDING
THE EXISTING SPACE. MODIFICATIONS TO THE INTERIOR WILL BE MADE
FOR INCORPORATION IN THE NEW LAYOUT OF THE SPACE. IN ADDITION,
PLUMBING, MECHANICAL, FIRE SPRINKLER SYSTEM AND ELECTRICAL
MODIFICATIONS WILL BE REQUIRED TO ACCOMMODATE THE NEW
REQUIREMENTS FOR THE PROPOSED GROCERY STORE. ALSO, INCLUDED
IN THE REMODEL WILL BE EXTERIOR SIGNAGE AND REPAINTING THE MAIN
CANOPY SIGN FACADE.
FIRST FLOOR OCCUPANT LOAD:
MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT:
AREA
LOAD FACTOR
MERCANTILE (SALES) AREA:
8,725 SF
( / 30)
STORAGE / MECHANICAL:
5,165 SF
( / 300)
OFFICE:
315 SF
( / 100
PREP:
340 SF
( / 200)
ASSEMBLY-UNCONCENTRATED:
205 SF
( /15)
TOTAL FIRST FLOOR OCCUPANT LOAD:
OCCUPANTS
= 291
= 17
=
3
=
2
= 14
= 327
GAS SERVICE
CUSTOMER SERVICE,
ATLANTA GAS LIGHT COMPANY.
PHONE: (800) 427-5463
WEB ADDRESS: www.atlantagaslight.com
FIRE MARSHAL
CRAIG LANDOLT- FIRE MARSHALL
CITY OF SAVANNAH FIRE DEPARTMENT,
121 E. OGLETHORPE AVE., SAVANNAH,
GA 31401
PHONE: (912) 644-5960
EMAIL: [email protected]
PLANNING DEPARTMENT
THOMAS F. BOLTON - ZONING INSPECTOR /
PLANS EXAMINER
PHONE: (912) 651-6530 EXT 1869
FAX : (912) 525 -1650
EMAIL: [email protected]
AND
RANDOLPH B. SCOTT - ZONING
ADMINISTRATOR.
PHONE : ( 912) 651- 6530 EXT 1848
FAX : ( 912) 525-1644
EMAIL: [email protected]
DEPARTMENT OF AGRICULTURE
DANIEL ESOE - AGRICULTURAL MANAGER,
GEORGIA DEPARTMENT OF AGRICULTURE,
19 MLK Jr. DRIVE, ROOM 312, ATLANTA,
GA 30334
PHONE: (404) 656-3621
EMAIL: [email protected]
ELECTRICAL SERVICE
BUSINESS CUSTOMER SERVICE,
GEORGIA POWER.
PHONE: (888) 655-5888
TELEPHONE SERVICE
AT&T
PHONE: 1-877-253-0009
TOTAL OCCUPANTS:
= 327
EGRESS WIDTH PER OCCUPANT SERVED:
REQUIRED: 0.2
MAIN FLOOR: 327 OCCUPANTS x 0.2 EGRESS WIDTH FACTOR = 65.4 INCHES
TOTAL REQUIRED:
= 65.4 INCHES
EXIT WIDTH PROVIDED: 198 INCHES (DIRECT FROM SALES FLOOR)
1- SWINGING DOOR UNIT @ 13'-6" = 162 INCHES
1-SALES EMERGENCY EXIT @ 3'-0" = 36 INCHES
I.D.
IN.
INT.
LBS.
MAX.
MFR.
MIN.
MAXIMUM TRAVEL DISTANCE - 250 FEET (WHEN FULLY SPRINKLED), (113' ACTUAL)
REQUIRED PLUMBING FIXTURES : (2009 UPC WITH ST. LOUIS COUNTY ORDINANCE & AMENDMENTS
CHAPTER 4 MERCANTILE, PAGE 88)
WATER CLOSETS - 1 FIXTURE PER 200 OCCUPANTS, 325 TOTAL OCCUPANTS (2 MALE, 2 FEMALE)
WOMEN:
2 REQUIRED,
1 PROVIDED
MEN:
2 REQUIRED,
1 PROVIDED (SEE NOTE #5, PAGE 93 OF CHAPTER 4 AMENDMENT)
LAVATORY:
WOMEN: 1REQUIRED, 1 PROVIDED
MEN:
1 REQUIRED, 1 PROVIDED
DRINKING FOUNTAIN:
2 REQUIRED,
2 PROVIDED
MOP SINK:
1 REQUIRED,
1 PROVIDED
FIRE SAFETY SYSTEMS:
SPRINKLER SYSTEM ( EXIST.)
YES x
NO _
SPRINKLER SYSTEM (EXT. CANOPY)
YES _
NO X
EMERGENCY LIGHTING & EXIT SIGNS
YES X
NO _
FIRE ALARM
YES X
NO _
SMOKE DETECTIONS SYSTEMS
YES X
NO _
PANIC HARDWARE
YES X
NO _
FIRE EXTINGUISHERS:
YES X
NO _
LOCATED IN QUANTITY AND LOCATIONS DIRECTED BY FIRE MARSHAL
PROJECT DIRECTORY
TENANT
ALLEN GREEN
SAVE-A-LOT FOOD STORES
3316, QUAIL RIDGE LANE
MATTHEWS, NC 28104
PHONE: (704) 956-8497
EMAIL: [email protected]
LANDLORD/OWNER
JOHN J. RAUERS
LAMARA COMPANY
101 BARNARD ST., SUITE 403,
SAVANNAH, GA 31401
PHONE: (912) 236-2461
CELL : (912) 429-3900
EMAIL: [email protected]
ARCHITECT
ANNE WAGNER, LEED AP, NCARB
SUPER VALU STORE DESIGN SERVICES
EAST VIEW INNOVATION CENTRE
(EVIC), 7075 FLYING CLOUD DR,
EDEN PRAIRIE, MN 553443307
PHONE: (952) 914-5873
FAX: (952) 914-5850
EMAIL: [email protected]
MECHANICAL
BOB KRAHN
STORE DESIGN SERVICES
EAST VIEW INNOVATION CENTRE
(EVIC), 7075 FLYING CLOUD DR,
EDEN PRAIRIE, MN 553443307
PHONE: (952) 914-5857
FAX: (952) 914-5850
EMAIL: [email protected]
STRUCTURAL ENGINEER
MARK MIELKE
VANSICKLE ALLEN
2955 XENIUM LANE # 10,
PLYMOUTH, MN - 55441
PHONE: (763) 577-9120
FAX: (763) 559-6023
EMAIL: mmielkeevaaeng.com
ELECTRICAL
BRUCE MC NEIL
STORE DESIGN SERVICES
EAST VIEW INNOVATION CENTRE
(EVIC), 7075 FLYING CLOUD DR.
EDEN PRAIRIE, MN 55344
PHONE: (952) 914-5843
FAX: (952) 914-5850
EMAIL: [email protected]
MISCELLANEOUS
MASONRY OPENING
MOUNTED
MOUNTING
NOT IN CONTRACT
NUMBER
NOT TO SCALE
ON CENTER
OUTSIDE DIMENSION
OPENING
OPPOSITE
ORIENTED STRAND BOARD
POUNDS PER LINEAL FOOT
PROJECT MANAGER (SAVE-A-LOT)
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
REFLECTED CEILING PLAN
REFER TO, REFERENCE FROM
REINFORCING
REQUIRED
ROUGH OPENING
SIMILAR
SPECIFICATIONS
STEEL
STRUCTURAL
SQUARE
TONGUE & GROOVE
TOP OF CURB/CONCRETE
TOP OF
TOP OF DRAIN
TYPICAL
VERTICAL
UNIFORM LOAD
UNIFORM DISTRIBUTED LOAD
WITH
WEATHERPROOF
WELDED WIRE FABRIC
AT
DETAIL
101
ROOM NUMBER
S-1
STRUCTURAL PLAN
S-2
STRUCTURAL NOTES AND DETAILS
PLUMBING DRAWINGS
P-1
DRAIN, WASTE AND VENT PLAN
P-2
WATER & GAS PIPING PLAN
P-3
PLUMBING SCHEDULES
P-4
PLUMBING DETAILS
MECHANICAL DRAWINGS
M-1
HVAC PLAN
M-2
HVAC SCHEDULES AND DETAILS
FIRE PROTECTION
FP-1
FIRE PROTECTION PLAN
ELECTRICAL DRAWINGS
E-0
ELECTRICAL DEMOLITION PLAN
E-1
LIGHTING PLAN
E-2
POWER PLAN
E-3
REFRIGERATION POWER PLAN
E-4
ENLARGED POWER PLAN AND DETAILS
E-5
RISER DIAGRAM AND SCHEDULES
REFRIGERATION DRAWINGS
SYMBOL LEGEND
XX
X-X
STRUCTURAL DRAWINGS
XXX
N
EQUIPMENT LIST
R-1
UTILITY COORDINATION PLAN (FOR REFERENCE ONLY)
R-2
REFRIGERATION SCHEDULE (FOR REFERENCE ONLY)
R-3
REFRIGERATION PIPING PLAN & LINE SIZING (FOR REFERENCE ONLY)
R-4
REFRIGERATION CONTROL WIRING DIAGRAMS (FOR REFERENCE ONLY)
R-5
EQUIPMENT DETAILS (FOR REFERENCE ONLY)
R-6
EQUIPMENT CUT SHEETS (FOR REFERENCE ONLY)
R-7
EQUIPMENT CUT SHEETS & CASE MISTING SYSTEM (FOR REFERENCE ONLY)
R-8
REFRIGERATION WIRE SIZING & DETAILS (FOR REFERENCE ONLY)
STORE NUMBER
473
PROJECT NUMBER
P03686-01
XX
X-X
SECTION
116A
07
XX
X-X
ELEVATION
DOOR NUMBER
KEY NOTE
INDICATOR
A
1
COLUMN GRID
REVISIONS
SHEET TITLE
COVER
SHEET
SHEET NUMBER
CS-1
TENANT FIT OUT
2006 INTERNATIONAL PLUMBING CODE WITH GA AMENDMENTS.
MISC.
M.O.
MT'D.
MT'G.
N.I.C.
NO.
NTS.
O.C.
O.D.
OPNG.
OPP.
O.S.B.
P.L.F.
P.M.
P.S.F.
P.S.I.
R.C.P.
RE:
REINF.
REQ'D
R.O.
SIM.
SPECS.
STL.
STRUC.
SQ.
T&G
T.C.
T.O.
T.D.
TYP.
VERT.
U.L.
U.D.L.
W/
W.P.
W.W.F.
@
SAVANNAH, GA - 31401
PLUMBING CODE:.
ANCHOR BOLT
ACOUSTIC CEILING PANEL
ABOVE FINISHED FLOOR
AND
ALUMINUM
ARCHITECTURAL
BUILDING
BOTTOM OF
BEARING
CENTER LINE
CUBIC FEET PER MINUTE
CONTROL JOINT
CONCRETE MASONRY UNITS
COLUMN
CONCRETE
CONTINUOUS
CYLINDER
DIAMETER
EACH
ELEVATION
EXTERIOR INSULATING FINISH SYSTEM
EXISTING
EXTERIOR
FOUNDATION
FINISHED OPENING
FACE OF CURB/CONCRETE
FACE OF MASONRY
FINISHED FLOOR
FEET
FOOTING
FIRE-RETARDANT
GAUGE
GALVANIZED
GALVANIZED IRON OR STEEL
GENERAL CONTRACTOR
GLUE LAMINATED STRUCTURE MEMBER
GYPSUM BOARD
GYPSUM WALL BOARD
HEADED CONCRETE ANCHOR
HOLLOW METAL
HORIZONTAL
HOUR
HEIGHT
HEATING VENTILATING AND AIR
CONDITIONING
INSIDE DIMENSION
INCH
INTERIOR
POUNDS
MAXIMUM
MANUFACTURER
MINIMUM
04/24/12
2006 INTERNATIONAL BUILDING CODE WITH GA AMENDMENTS.
A.B.
A.C.P.
A.F.F.
&
ALUM.
ARCH.
BLDG.
B.O.
BRG.
C.L.
CFM
C.J.
CMU
COL.
CONC.
CONT.
CYL.
DIA.
EA.
ELEV.
E.I.F.S.
EXIST.
EXT.
FDN.
F.O.
F.O.C.
F.O.M.
F.F.
FT.
FTG.
FR.
GA.
GALV.
G.I.
G.C.
G.L.
GYP. BD.
GWB.
H.C.A.
H.D.
HORIZ.
HR.
HT.
HVAC
DATE:
BUILDING CODE:
WATER SERVICE / SANITARY SEWER
CITY OF SAVANNAH UTILITY SERVICES
DEPARTMENT,
TOM VANDERHORST, DEPARTMENT HEAD.
132 E. BROUGHTON ST., SECOND FLOOR,
SAVANNAH, GA
PHONE: (912) 651-6460
2400 BULL STREET,
BUILDING DEPARTMENT
CITY OF SAVANNAH, GOVERNING
MUNICIPALITY,
JASON CARANGELO - BUILDING
INSPECTIONS ADMINISTRATION,
DEVELOPMENT SERVICES DEPARTMENT,
5515 ABERCORN ST., SAVANNAH,
GA 31405
PHONE: (912) 651-6530
EMAIL: [email protected]
AW
BUILDING CODE DATA:
ABBREVIATIONS
CHECKED:
GOVERNMENTAL AGENCIES
MG
SITE LOCATION
CODE / PROJECT DATA
DRAWN:
SITE MAP
DOOR AND ROOM FINISH SCHEDULES AND NOTES