yaggy colby - Olmsted County

Transcription

yaggy colby - Olmsted County
SITE SUMMARY
BLVD. TREES TYP. (6 EA.)
- OWNER TO INSTALL THE APPROPRIATE BLVD. TREE AND
PROVIDE WARRANTY TO THE CITY OF ROCHESTER PARKS DEPARTMENT
OR
- BLVD. TREES TO BE INSTALLED BY CITY OF ROCHESTER PARKS DEPARTMENT
AND THE OWNER TO PAY THE GOING RATE PER TREE TO THE PARKS DEPARTMENT
ZONING CLASSIFICATION:
PROPOSED USAGE:
B-4
TRADE SHOPS (TYPE 1)
TOTAL SITE AREA =
TOTAL SITE ACREAGE =
13TH AVENUE NW
9,480.00 S.F.
0.22 ACRES
FLOOR AREA CALCULATIONS
B-4 MAXIMUM =
2,332 + 2,478EX = 4,810 TOTAL G.F.A. =
0.50 F.A.R.
0.50 F.A.R.
PARKING CALCULATIONS
REQUIRED (1/EMP + 1/200SF SALES AREA) 7
PROPOSED STALLS W/O HAN DICAP STALLS = 7
PROPOSED HANDICAPPED STALLS = 1
GREENSPACE CALCULATIONS
REQUIRED (9,480 SQ. FT. x 10%) =
PROPOSED =
948 S.F.
969 S.F.
EXTERIOR LIGHTING REGULATION STANDARD:
SIGN REGULATION STANDARD:
EXTERIOR STORAGE REGULATION STANDARD:
BUFFERYARD INDICATOR:
BUFFERYARD CLASS (10' WIDTH):
D
C
YAGGY
COLBY
ASSOCIATES
ENGINEERS
LANDSCAPE ARCHITECTS
SURVEYORS • PLANNERS
717 THIRD AVENUE SOUTHEAST
ROCHESTER, MINNESOTA 55904
507-288-6464
FAX 507-288-5058
EMAIL [email protected]
T,S,50%
VIII
D
CANOPY PLANTINGS (2.5*607100')
UNDERSTORY PLANTINGS (5.0*607100")
SHRUBS (8.0*607100')
2:
ti
LU
oi
SETBACK REQUIREMENTS:
REQUIRED FRONT YARD:
MIN. REQUIRED SIDE YARDS:
X
MIN. SUM OF SIDE YARD:
MIN. REAR YARD:
REQUIRED SIDE STREET SIDE YARD:
15 FEET
0 FEET
0 FEET
0 FEET
7.5 FEET*
* TYPE 1 DESIGN MODIFICATION APPLIED FOR.
OWNER
JOSEPH AND CINDY BOWMAN
1219 7TH STREET NW
ROCHESTER, MINNESOTA 55901
PHONE NO. (507) 282-7779
u
O
_i
<
Q
Z
<
I-
o
co
LU
Z
z
<
Q_
UJ
LT)
H
CD
SITE ADDRESS
1219 7TH STREET NW
ROCHESTER, MN 55901
I
U
<
o
DESCRIPTION
Lot 10, Block 4 Repldt 4 & 10 Gooding's Addition, according to the plat therefore on
file at the County Recorder's office, Olmsted County, Minnesota.
LEGEND
o
CO
PROPOSED BUILDING
GENERAL NOTES
UTILITY CLASSIFICATION
PER MINNESOTA STATUTES 2002, SECTION 216D.04, SUBDIVISION 1A. THE EXISTING
UNDERGROUND UTILITIES FOR THIS PROJECT SHALL BE CONSIDERED A "D" CLASSIFICATION.
UTILITY CONNECTIONS NOTE
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PERFORM OR COORDINATE ALL
NECESSARY UTILITY CONNECTIONS FROM EXISTING UTILITY LOCATIONS TO THE PROPOSED
BUILDING AND PROPOSED ON SITE AMENITIES. THESE CONNECTIONS INCLUDE BUT ARE NOT
LIMITED TO WATER. SANITARY SEWER, CABLE T.V.. TELEPHONE. GAS. ELECTRIC. ON-SITE
ELECTRIC. SITE LIGHTING. SIGNAGE. ETC.
1.) ALL WORK SHALL CONFORM TO AND BE PERFORMED IN
ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES.
2.) THE SPECIFICATIONS AND DETAILS AS PREPARED BY THE CITY
ROCHESTER SHALL BE CONSIDERED A PART OF THESE DOCUMENTS
AS IF BOUND HEREIN.
3.) THE CONTFiACTOR SHALL NOTIFY ALL APPROPRIATE ENGINEERING
DEPARTMENTS AND UTILITY COMPANIES 72 HOURS PRIOR TO
CONSTRUCTION. ALL NECESSARY PRECAUTIONS SHALL BE TAKEN TO
AVOID DAMAGE TO ANY EXISTING UTILITY.
4.) THE LOCATION OF EXISTING UNDERGROUND UTILITIES AND ROCK
ELEVATIONS ARE SHOWN IN AN APPROXIMATE WAY ONLY AND HAVE
NOT BEEN INDEPENDENTLY VERIFIED ffY THE OWNER OR ITS
REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT
LOCATION OF ALL EXISTING UTILITIES AND ROCK ELEVATIONS BEFORE
COMMENCING WORK. AND AGREES TO BE FULLY RESPONSIBLE FOR ANY
AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY THE CONTRACTOR'S
FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND
UTILITIES AND ROCK ELEVATIONS.
5.) THE CONTRACTOR SHALL VISIT THE SITE AND INSPECT THE PROJECT
AREA AND THOROUGHLY FAMILIARIZE HIMSELF WITH THE ACTUAL JOB
CONDITIONS PRIOR TO BIDDING AND THE START OF ANY WORK.
FAILURE TO VISIT THE SITE SHALL NOT REUEVE THE CONTRACTOR
PROPOSED LANDSCAPING
O
or
RECEIVED ^
o
CANOPY PLANTINGS (2 EA.)
I?
to
UNDERSTORY PLANTINGS (3 EA.)
00
REVISION HISTORY
BOULEVARD TREES (6 EA.)
- SEE NOTE ABOVE
THE CONTRACTOR SHALL VERIFY AT THE SITE, ALL DIMENSIONS AND
CONDITIONS SHOWN ON THE DRAWINGS, AND SHALL NOTIFY THE
ENGINEER OF ANY DISCREPANCIES. OMISSIONS, AND/OR CONFLICTS
PRIOR TO PROCEEDING WITH THE WORK.
7.) THE CONTRACTOR SHALL NOT SCALE DRAWINGS. DIMENSIONS SHALL
GOVERN. LARGE SCALE DRAWINGS SHALL GOVERN OVER SMALL
SCALE DRAWINGS. NOTES AND DETAILS ON THE DRAWINGS SHALL
APPLY TO ALL SIMILAR CONDITIONS WHETHER THEY ARE REPEATED
OR NOT.
J.) THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL "AS-BUILT"
LOCATIONS OF PUBLIC AND PRIVATE INFRASTRUCTURE. AND MUST
NOTIFY THE PROJECT ENGINEER PRIOR TO INSTALLATION.
6.)
SHRUBS (5 EA.)
SHEET NUMBER
EXISTING TREE
2"TREE
SCALE IN FEET
<
_J
C1.0
ONE
CO