Electrically heated gas sample probe series SP Version SP2020-H(220)/C/I/BB and SP2020-H(220)/C/I/BB/F

Transcription

Electrically heated gas sample probe series SP Version SP2020-H(220)/C/I/BB and SP2020-H(220)/C/I/BB/F
2
Electrically heated gas sample probe
series SP®
Version SP2020-H(220)/C/I/BB and
SP2020-H(220)/C/I/BB/F
SP 2020-H
Heated sample probe with
integrated valves for:
Description
• Calibration gas injection
The M&C probe SP2020-H(220)/C/I/BB and /BB/F is based on the standard probe
SP2000-H.
• Probe outlet isolation
•
Calibration gas will be injected into the probe through a check valve /C
directly to the sample outlet. No calibration gas is lost into the stack.
•
An isolation valve /I shuts off the sample outlet from the internal filter area.
•
Through a high flow rate check valve /BB, which is fixed to the internal
probe area, blow back of the filter housing area and the insitu probe
tube will be done.
•
Through a high flow rate check valve /BB/F, which is fixed to the filter
housing wall, blow back of the incorporated ceramic filter will be done
incl. the filter area and the insitu probe tube.
• Blow back
1/2
2-1.1.6.1
© M&C 09.96 / 06.01 Technical details are subject to change. Copying, including extracts, not permitted unless authorized by M&C.
M&C Products Analysentechnik GmbH • Rehhecke 79 • 40885 Ratingen • Germany • Tel.: +49 (0) 21 02 / 9 35-0 • Fax: / 9 35-111 • E-mail: [email protected] • www.muc-products.de
2
Dimensions
SP2020-H/C/I/BB
Tube 3/8" o.d.
SP2020-H/C/I/BB/F
Tube 3/8" o.d.
Check valve
1/4"NPT
Check valve
1/4"NPT
Isolation valve
Flange 3" 150lbs RF
Check valve
Isolation valve
Flange 3" 150lbs RF
1/8"NPT
1/8"NPT
Tube 1/4" o.d.
Tube 1/4" o.d.
Cal.-gas in Sample out Blow back in Control in
(P 1-6bar)
(P >0,7bar)
(P 3-10bar)
Cal.-gas in Sample out Blow back in Control in
(P 1-6bar) (P 3-10bar)
(P >0,7bar)
Dimensions in mm
Following options are included:
Flange
Power
Calibration gas connection
Blow back gas connection
Operating temperature max. 220 °C
Calibration gas injection valve
Isolation valve
Valve for blow back of the filter housing area
Valve for blow back of the incorporated ceramic filter
Technical specifications
Part Number
Operating temperature
Power supply
Calibration gas valve /C
Isolation valve /I
Blow back valves / BB
Blow back valves /BB/F
Flange
SP2020-H....
3“ 150 Ibs
115V AC
tube connector 1/4“o.d.
tube connector 3/8“o.d.
/H220
/C
/I
/BB
/BB/F
SP2020-H/C/I/BB
SP2020-H/C/I/BB/F
SP2020-H220/C/I/BB
SP2020-H220/C/I/BB/F
20S2020a
20S2025a
20S2021a
20S2030a
max. 180 °C
max. 220°C
115V 60Hz, 630W
Check valve, cracking pressure: >0,7 bar g
connection: tube connector 1/4“ o.d.
Bellow valve with pneum, actuator, control pressure: 3-10 bar g
connection: 1/8“NPT i
High flow rate check valve, cracking pressure: >0,7 bar g, recommended: 3-6 bar g
we recommend short pressure pushes to avoid decreasing of temperature in blow back area.
connection: tube connector 3/8“ o.d.
material: stainless steel 316Ti, dimensions: 3“ 150 Ibs
For further technical informations see standard probe SP2000-H.