8MW Nominal Capacity - Dresser-Rand
Transcription
8MW Nominal Capacity - Dresser-Rand
EPS100 Heat Recovery Solution S Heat Recovery Solution EPS100 8MW Nominal Capacity Process skid Echogen’s EPS100 Heat Recovery System is an advanced Rankine Cycle for usable [waste] heat recovery. Our patented technologies operate over a broad range of heat sources to extract a significant amount of energy and convert it into higher value, usable power. We use industrial-grade CO2 as the working fluid, which allows our system to deliver reliable power from a more compact, flexible, and low‐cost thermal engine. Power output can be optimized for a large range of heat sources depending on the application. Echogen’s economic, emission‐free power will enable fuel-intensive operations to lower the cost of energy, meet higher environmental standards, and improve bottom-line performance. Simplified EPS100 CO2 Heat Recovery Cycle Benefits Economic Generates power at a competitive installed cost, reducing overall cost of electricity Small Footprint System components are compact, yielding a smaller skid-based system for ease of installation Clean Produces fuel-free, emission-free electricity to meet environmental regulations Safe Working fluid is environmentally benign, non-toxic and non-flammable Air or Water-Cooled No water required for operation Low Maintenance System is fully automated and does not require on-site personnel Technical Support Global support available with Dresser-Rand service plans Materials and specifications are subject to change without notice. © 2013 Echogen Power Systems LLC. All rights reserved. May 2013 Long Product Lifetime High-quality manufacturing and non-corrosive fluids extend the integrity and life of system components Echogen Power Systems | 365 Water Street | Akron, OH 44308 | 234.542.4379 | echogen.com HEAT RECOVERY APPLICATIONS EPS100 Heat Recovery Solution Gas Turbines Reciprocating Engines Component Design Generator Synchronous 13.8 kV Turbomachinery CO2 pump and turbo expander Diverter Valve Option* Fully actuated operation Flow modulation Design Standards ASME Section VIII ASME 31.3 NEMA4, IEEE Pressure Vessel Construction Piping Electrical Components * Integrated with plant operation and control system and configured to site requirements System CO2, industrial-grade PLC based LAN/WAN Designed for remote control Skid-based Working Fluid Controls Remote Monitoring Operation Package Reference Conditions °C % °C kg/s kW Ambient Temperature (ISO) Humidity (ISO) Waste Heat Supply Temperature Waste Heat Flow Rate Waste Heat Input 15 60 532 68 33,300 °F % °F lb/hr MMBTU/h Electrical Output Generator Output** MW 8 **Does not include Parasitic and Auxiliary loads. Based on water-cooled option. General Specifications Voltage Input*** Frequency*** Process Skid Power Skid Control House Size Envelope (L x W x H) Weight, Dry Size Envelope (L x W x H) Weight, Dry Size Envelope (L x W x H) Weight, Dry V Hz m kg m kg m kg 11x3x4 54,431 11x3x4 52,160 4x3x4 7,031 480 VAC, 3-phase, 1200 amps 60 ft 35x11x12 lb 120,000 ft 35x11x12 lb 115,000 ft 12x10x12 lb 15,500 Other equipment not specified: CO2 storage unit, refrigeration system, and vaporizer ***Additional voltage and frequency specifications available (50Hz) The bottom line in efficient energy. Echogen Power Systems | 365 Water Street | Akron, OH 44308 | 234.542.4379 | echogen.com 59 60 990 540,644 114