WPL 33 Kompakt luft/vand-varmepumpe

Transcription

WPL 33 Kompakt luft/vand-varmepumpe
Relative humidity %
Air temperatureoC
%
10
Lufttemperatur oC
Relativ fugtighed %
%
20
60
30%
55
50
1.100
40%
45
50%
60%
40
35
30
40
35
g
/k
kJ
20
30
25
g
/k
kJ
10
0
g
/k
kJ
90
g
/k
kJ
40
10
5
1.300
ing
n
tio
m
a
d
r
e
tu
)v
sa
(h
t
i
)a
lp
(h
ha
y
t
En halp
t
En
n
æt
g
/k
kJ
30
1.250
g
/k
kJ
50
15
g
/k
kJ
60
20
g
/k
kJ
70
1.200
g
/k
kJ
80
25
20
-5
15
1.350
-10
10
-15
5
-20
0
0
5
10
15
Vandindhold (x) i g vand/kg luft
Water content (x) in g water/kg air
20
25
Water vapour pressure (mbar)
1.150
70%
80%
90%
%
100
Vanddamptryk (mbar)
Luftens densitet kg/m3
Air density kg/m3
MOLLIER HX-DIAGRAM
MOLLIER HX-DIAGRAM
Begreber i Molliers hx-diagram
Luftens densitet (ρ)
Den lodrette orange akse helt ude til venstre. Aflæs luftens densitet ved at følge den skrånende orange linje i diagrammet.
Luftens densitet er den specifikke massefylde angivet i kg/m3.
Lufttemperatur (t) Den lodrette pink akse i venstre side med tilsvarende let skrånende linjer.
Temperaturen angives i °C.
Enthalpi (h)
De lilla diagonale linjer.
Enthalpi er luftens vameindhold og angives i kJ/kg luft.
Starter ved 0°C = 0 kJ/kg.
Relativ fugtighed (RF)
De grønne kurver. Den relative fugtighed angives i procent (%) og er et udtryk for luftens aktuelle vanddamptryk i forhold til vanddamptrykket ved mætning.
Vandindhold (x)
Den vandrette lyseblå akse nederst.
Det aktuelle vandindhold i luften målt i g vand/kg luft.
Vanddamptryk (p)
Den lodrette blå akse til højre. Vanddamptryk målt i mbar aflæses for at bestemme det
partielle vanddamptryk. Den brune diagonale linje i nederste halvdel af diagrammet er en
hjælpelinje til brug for bestemmelse af det partielle vanddamptryk.
Bemærk at hx-diagrammet brugt i denne guide gælder for et atmosfærisk tryk på 1013 mbar.
The Mollier hx-diagram quantities
Air density (ρ)
The vertical orange axis to the extreme left. Read the air density by following the slanting orange lines in the diagram.
Air density is the specific gravity measured in kg/m3.
Air temperature (t) The vertical pink axis to the left with corresponding slightly slanting horizontal gridlines.
Temperature is measured in °C.
Enthalpy (h)The purple diagonal lines. The enthalpy is the heat
energy content of the air measured in kJ/kg air.
Starting at 0°C = 0 kJ/kg.
Relative humidity (RH)The green curved lines. The relative humidity is the proportion of actual water vapour pressure in the air expressed as a percentage (%) of the water vapour pressure at saturation.
Water content (x)
The horizontal light blue axis at the bottom.
The actual water content of the air measured in g water/kg air.
determine the partial water vapour pressure (rarely used when calculating the dehumidification
load). - The brown diagonal line in the bottom half of the diagram is a help line used when
determining the partial water vapour pressure.
Note that the hx-diagram used throughout this booklet applies to an atmospheric pressure of 1.013 mbar.
dantherm.com
04.08.500
Thorvig Tryk, Skive
Water vapour pressure (p) The vertical blue axis to the right. The water vapour pressure measured in mbar is read to